You are on page 1of 2

® Industrial Diesel Generator Set – PDG-40SQ-E

60 Hz – Soundproof Stage 3 Low Emission

Enclosure

 Conforms to North American standard NEMA 250-3R


suitable for outdoor use rain or shine. Equivalent to IP
24 in European standard.
 Factory rust proofed.
 Equipped with lift handle centrally positioned for
balance lifting by boom truck or crane with proper
slings for transporting the generator set. (Note: Slings
are not included in the product).
 Conforms to ISO 8528-1 for fully resilient mounting
PDG-40SQ-E
with integral rubber anti-vibration mounts to ensure
Powercity premium quality vibration damping.

 Soundproof & weatherproof Fuel Tank


 Complete standalone unit
 Rated load and overload tested  300 liters double wall skid base fuel tank.
 Pure sine wave voltage output  Double wall for spill containment.
 User friendly & compact digital controller  Close top dike construction to resist precipitation or
 Automatic Voltage Regulator (AVR) debris from entering the dike area.
 Noise level (65 dB(A) @7 meters)  Lockable fuel filler cap prevents fuel theft.
 Stage 3 low emission CRDI engine  Passive fuel gauge indicating fuel level. (Note: Fuel
 Integral vibration isolators level, in percentage, can also be monitored from the
 300 liters double wall skid base fuel tank generator controller).
 Designed with normal vent and emergency vent in
Ratings conformance to UL 142 and NFPA 30.

 220/440V – 60 Hz Control Panel


 Standby: 45 kVA – 36 kWe
 Prime: 40kVA – 32 kWe  Digital display with intelligent processor and user-
friendly features. User can manually start and stop the
Engine generator set or put the unit into automatic mode to
make it start automatically when grid power failure
 Common Rail Direct Injection (CRDI) engine occurred.
 Electronic Engine Control Unit (ECU) for precise engine  SCADA capability (optional) with choices of
management, fuel efficiency and lower emission for communication interface using LINK, RS485, RS232,
modern engines. USB, CANBUS, GSM and ETHERNET.
 Low temperature starting capability.
 Minimizes wet stacking at low load operation. Product Conformance

Alternator  NEMA MG1: Motors and Generators


 ISO 8528-1: Reciprocating internal combustion engine
 Brushless, self-excited (shunt type) for simple and cost- driven alternating current generating sets – Part 1:
effective solution. Application, ratings, and performance.
 Built with class H insulation and IP 21 enclosure.  ISO 8528-3: Reciprocating internal combustion engine
 Factory impregnated epoxy varnished. driven alternating current generating sets – Part 3: AC
 Heavy duty steel frame cast-iron cover. generators for generating sets.
 Stator grease insulation covered.  IEC 34-1: Rotating electrical machines – Part 1: Rating
 Flywheel location cooling fan. and performance.
 Manufactured in conformance to NEMA MG1, ISO  BS 5000-3: Rotating electrical machines of particular
8528-3, IEC 34-1, and BS 5000-3 standards. types or for particular applications – Part 3: Generators
to be driven by reciprocating internal combustion
Cooling
engines – Requirements for resistance to vibration.
 Compact and complete solution using a mechanically  ANSI/NEMA 250: American National Standard for
driven radiator fan. Enclosures for Electrical Equipment (1000 Volts Max.)
 Standard cooling system which can operate at ambient  UL 142: Steel Aboveground Tanks for Flammable and
temperatures of 40 degrees Celsius. Combustible Liquids
 NFPA 30: Flammable and Combustible Liquids Code
RATINGS: All units are rated 0.8 power factor.
Standby Rating: The generator can provide power to a variable load for the duration of utility power outage with maintenance intervals carried
out as prescribed by manufacturer. Average load factor over 24-hour period of operation shall not exceed 70% for this rating. Prime Rating: The
generator can provide power to a variable load for unlimited number of hours with maintenance intervals carried out as prescribed by
manufacturer. Average load factor over 24-hour period of operation shall not exceed 70% for this rating. Ratings are in accordance with ISO-
8528-1. The generator set manufacturer reserves the right to change the design or specification without notice and without any obligation or
liability whatsoever.
® Industrial Diesel Generator Set – PDG-40SQ-E
60 Hz – Soundproof Stage 3 Low Emission

Certification Control Panel


HGM6110CAN
 CE The generator set is operated thru its
 CQC reliable and intelligent digital controller
 CSAC, CSAUS, UL (sub-assembly only where applicable) and displays parameters including:
Voltage (V), Current (I), Frequency (Hz),
SPECIFICATIONS Active Power (kW), Reactive Power (kVar),
Power Factor (PF), Accumulated Energy
Model PDG-40SQ-E (kWh), Coolant Temperature (°C/°F), Oil Pressure (kPa/PSI/Bar),
Alternator Fuel Level (%), Engine Speed (RPM), Battery Voltage (V), Charger
Make & Model Powercity TWG 224D Voltage (V), Run Hours (max. 999999 hours), Start Times (max.
Frequency Hz 50 60 999999 hours), Warnings and Alarms. With SCADA capability via
Rating (kVA) Prime 35 40 RS485, RS232 and USB.
Standby 40 45
Phase 3 – Phase (4 wires) or 1-Phase(3 wires)
Rated Voltage V 200~240/380~480
Power Factor 0.8 (Lagging) Good Electronic Engine Control Unit (ECU)
Voltage Regulation % +/- 1.5 provides precise engine management, fuel
Brushless rotating exciter with efficiency and lower emission for modern
Excitation Automatic Voltage Regulator (AVR) engines.
Insulation Class H
Engine
Make & Model Powercity 4B5-62C31 Balanced Rigging Point
Type Veritcal inline, 4 Stroke, Water Equipped with balanced
cooled,Turbo charged, Common rail rigging point for lifting the
direct injection generator set during
Output Rating Kw/rpm 38 45.5 transport. The generator set
No. of Cylinders – mm 4-95x100 can be safely and
Bore x Stroke conveniently lifted by crane
Piston Displacement L 2.83 or boom truck with proper
Fuel ASTM No. 2 Diesel slings. (Note: Slings not included in the generator unit).
Fuel Consumption L/h 5 6
@ 75% Load Emergency Vent
Lube Oil Capacity L 6
In conjunction with normal vent, emergency
Coolant Capacity L 21
vent fitted on base tank helps prevent the tank
Battery Capacity V-Ah 12V-80Ah
from becoming over-pressurized and rupturing
Fuel Tank Capacity L 300
if tank is exposed or engulfed into massive fire.
Unit
Emergency vent serves as pressure relief
L, mm 2000
preventing tank explosion in conformance to
Dimensions W, mm 830
UL 142 and NFPA 30 requirements on aboveground fuel tanks.
H, mm 1500
Dry Weight Kg 1250
Threaded exhaust pipe
Sound Level
provisioned for extending
dB(A) @ 7 m. 62 65
exhaust in indoor
Note: The generator set manufacturer reserves the right to
installation of generator
change the design or specification without notice and without any
set. Flexible flange
obligation or liability whatsoever.
adaptor included.

Manufactured by:
Powercity Electromechanical & Equipment Co. Ltd.
Laicuo Industrial Zone, Xiyuan Side, Jinjiang City, Fujian, China
H Tel. +86-595-85301789, Fax. +86-595-85301608

Philippine Distributor:
Powercity Corporation
Km. 20, East Service Road, Muntinlupa City, Metro Manila
Tel. +63-2-8869-1991, Fax. +63-2-8869-3869
L
Made in China
W

RATINGS: All units are rated 0.8 power factor.


Standby Rating: The generator can provide power to a variable load for the duration of utility power outage with maintenance intervals carried
out as prescribed by manufacturer. Average load factor over 24-hour period of operation shall not exceed 70% for this rating. Prime Rating: The
generator can provide power to a variable load for unlimited number of hours with maintenance intervals carried out as prescribed by
manufacturer. Average load factor over 24-hour period of operation shall not exceed 70% for this rating. Ratings are in accordance with ISO-
8528-1. The generator set manufacturer reserves the right to change the design or specification without notice and without any obligation or
liability whatsoever.

You might also like