1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm
2. Material
(1) : 21.00MPa
(2) : 275MPa
(3) : 275MPa
300
350
3. Section
(1) Section Size : 350 x 300mm
(2) : 3.800m
(3) : 3.800m
(4) : 0.500
(5) : 0.500
(6) Splicing Limit : 50%
(7) Frame Type : Braced Frame
4. Forces
(1) : 104kN
(2) : 16.07kN·m
(3) : 25.29kN·m
(4) : 15.25kN
(5) : 8.270kN
(6) : 104kN
(7) : 104kN
5. Factors
(1) : 1.000
(2) : 1.000
(3) : 1.000
6. Rebar
(1) Main Bar
ㆍ Layer-1 = = 1,207mm² )
ㆍ Layer-2 :-
ㆍ Layer-3 :-
ㆍ Layer-4 :-
ㆍ : 1,207mm²
(2) Hoop Bar
ㆍ End : d10@50.00
ㆍ Middle : d10@100
(3) Tie Bar
ㆍ Apply Tie Bar to Shear Check : Yes
ㆍ Tie Bar = 227MPa )
7. Option
(1) Special provisions for seismic design is applied.
(2) Frame Type : Special Moment Frame
P (kN)
2250
θ=58.50˚
1975
N.A=53.97˚
1700
1425
1150
1136
eb=276.78mm
875
600
325
(224,64)
50 (104,30) M (kN·m)
0
-225
-500
0
15
30
45
60
75
90
105
120
135
150
15. Calculate Shear Force by Special Provisions for Seismic Design ( Direction Y ).
(1) Calculate bending strength for design shear force.
ㆍ ø = 1.000
ㆍ = 104kN·m
ㆍ = 104kN·m
ㆍ = 104kN·m
ㆍ = 104kN·m
(2) Calculate design shear force by special provision for seismic design
ㆍ = = 57.72kN
ㆍ = = 57.72kN
ㆍ = = 57.72kN
16. Calculate Shear Force by Special Provisions for Seismic Design ( Direction X ).
(1) Calculate bending strength for design shear force.
ㆍ ø = 1.000
ㆍ = 110kN·m
ㆍ = 110kN·m
ㆍ = 110kN·m
ㆍ = 110kN·m
(2) Calculate design shear force by special provision for seismic design
ㆍ = = 54.52kN
ㆍ = = 54.52kN
ㆍ = = 54.52kN