You are on page 1of 6

20230

A B
50MM Ø B.I. PIPE SCHED. 40 CENTER LINE
TOP CHORD (FULL WELD) OF TRUSS

STRUT-1

700.00 700.00 700.00 700.00


STRUT-2 STRUT-2
38MM Ø B.I. PIPE SCHED. 40
WEB MEMBER (FULL WELD)

4250 4250
38MM Ø B.I. PIPE SCHED. 40 WEB MEMBER
(FULL WELD)

50MM Ø B.I. PIPE SCHED. 40


BOTTOM CHORD (FULL WELD) ELEVATION
50MM Ø B.I. PIPE SCHED. 40
CAMBER (FULL WELD)

GIRT-2 GIRT-2
Ø200mm B.I PIPE COLUMN (TYPICAL)

1 ARC TRUSS 2 DETAIL 50MM Ø B.I. PIPE SCHED. 40


TOP CHORD (FULL WELD)
6 7 SCALE 1:50 MTS.

38MM Ø B.I. PIPE SCHED. 40

550
WEB MEMBER (FULL WELD)

50MM Ø B.I. PIPE SCHED. 40


BOTTOM CHORD (FULL WELD)

50MM DIA B.I. PIPE S-40 WEB MEMBERS


SECTION
(FULL WELD) D
C
600 600 600
100MM DIA B.I. PIPE S-40 TOP
25MM DIA B.I. PIPE S-40 TOP 25MM DIA B.I. PIPE S-40 TOP
(FULL WELD)
(FULL WELD) (FULL WELD) 25MM DIA B.I. PIPE S-40 WEB
800
(FULL WELD)

550 550 550 550 550


100MM. DIA PIPE S-40 BOTTOM
(FULL WELD)

GIRT-2

550
550

2 GIRT 2 DETAIL
6 7 SCALE 1:75 MTS. 25MM DIA B.I. PIPE S-40 BOTTOM
25MM DIA B.I. PIPE S-40 BOTTOM (FULL WELD)
(FULL WELD)

3 STRUT 2 DETAIL
6 7 SCALE 1:75 MTS.

REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GLENN A. DALAPO
REGION - X Engineering Assistant
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE REHABILITATION OF MULTI-PURPOSE ARC TRUSS 2 DETAIL
BUILDING (COVERED COURT) STRUT 2 DETAIL RAEMAN BHEE M. APUGAN HAROLD C. CAERMARE RONALD T. GEMPISAO MARIVEL FRANCES L. ONG, A.E.R. S 19
GIRT 2 DETAIL DESIGNED:
Engineer II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. PANABOL, KINOGUITAN, MISAMIS ORIENTAL JOSHUA B. DELA PENA DATE: DATE: DATE: DATE: 6 7 22
Brgy. 26, Gingoog City
Engineer II
20230

A CENTER LINE
OF TRUSS
B

R20224

R19749
2390

700.00 700.00 700.00 700.00


2222

1939

1535

1004

75MM Ø B.I. PIPE SCHED. 40


BOTTOM CHORD (FULL WELD) ELEVATION

1000 1500 1500 1500 1500 1500

1 ARC TRUSS DIAGRAM


7 7 SCALE 1:50 MTS.

REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GLENN A. DALAPO
REGION - X Engineering Assistant
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE REHABILITATION OF MULTI-PURPOSE
BUILDING (COVERED COURT) ARC TRUSS DIAGRAM RAEMAN BHEE M. APUGAN HAROLD C. CAERMARE RONALD T. GEMPISAO MARIVEL FRANCES L. ONG, A.E.R. S 19
DESIGNED:
Engineer II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. PANABOL, KINOGUITAN, MISAMIS ORIENTAL JOSHUA B. DELA PENA DATE: DATE: DATE: DATE: 7 7 22
Brgy. 26, Gingoog City
Engineer II
P. PLUMBING

REHABILITATION OF MULTI-PURPOSE BUILDING


(COVERED COURT)
BRGY. PANABOL, KINOGUITAN, MISAMIS ORIENTAL
PLUMBING NOTES
N 1. ALL PLUMBING PLAN SPECIFICATIONS AND SHOP DRAWINGS
SHALL MEET ALL REQUIREMENTS SET BY THE NATIONAL
BUILDING CODE,NATIONAL PLUMBING CODE, AND THE LOCAL
W E CODE OF CAGAYAN DE ORO CITY.
THIS SITE PROPOSED FOR
DEMOLITION 2. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL
PROP. MPB S
DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED, MODIFY
TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.
CARE
TH
HEAL

DAY
CARE
3. SHOP DRAWINGS WITH THE ERECTION AND PLACING OF
LL
STAG
E
PLUMBING MEMBERS SHALL BE SUBMITTED FOR THE
BRGY
. HA

ENGINEER/DESIGNER'S APPROVAL BEFORE FABRICATION.


4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS,
ANY RELOCATIONS REQUIRED PROPER EXECUTION OF OTHER
TRADES SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT
OR ENGINEER.
WAI
SHED
TING
EXIS
RAMP
T.

5.PROPOSED PLUMBING UTILITIES SHALL CONFORM TO THE


ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF ALL
EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE
CONTRACTOR.
6. PLUMBING INSTALLATION SHALL NOT IMPAIR THE STRENGTH
OF ANY STRUCTURAL MEMBER, COORDINATE WITH STRUCTURAL
PLANS AND DETAILS.
7. MATERIALS USED IN INSTALLATIONS SHALL BE OF
APPROVED BRAND, FREE FROM ANY DEFECTS AND PASSED
THE QUALITY SET FORTH BY THE BUREAU OF PHIL.
SITE DEVELOPMENT PLAN
1 SITE DEVELOPMENT PLAN STANDARDS.
1 3 SCALE NTS 8. ALL PIPES AND UTILITIES SHALL BE ANCHORED TO A FIXED
SUPPORT.
9. ALL SLOPE FOR SEWER HORIZONTAL BRANCHES SHALL
MAINTAIN A 2% SLOPE MINIMUM UNLESS OTHERWISE SPECIFIED.
10. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN
ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.
11. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT
SITE AND COORDINATE THE WORKS WITH THE SEWER LINE
EFFLUENT DISPOSAL POINT AND WATER LINE SERVICE

PER
12. CONNECT ALL SEWER INSTALLATION TO A STANDARD
OO
GP
RO
SEPTIC TANK IN THE ABSENCE OF SEWER SYSTEM.
ING
TOG
13. MINIMUM EARTH COVER OF 300mm SHALL BE OBSERVED
FOR ALL PLUMBING PIPES.
14. CONNECT ALL PLUMBING INSTALLATIONS WITH THE
APPROPRIATE FITTINGS USING PROCEDURES. SEE
Y
MANUFACTURERS SPECIFICATIONS.
WA
IGH
LH
NA
TIO
NA 15. CONDUCT PROPER ROUGHING-INS AND/OR WATER TEST
PRIOR TO POURING TO ENSURE AGAINST LEAKAGE.
Y
CIT
CD
O
16. ALL PLUMBING FIXTURES SHALL BE AS PER ARCHITECTS
TO THIS SITE SPECIFICATIONS.
17. ALL PLUMBING INSTALLATIONS AS INDICTED HEREIN SHALL
BE DONE AS PER PLANS AND SPECIFICATIONS; NO
ALTERNATIONS SHALL BE DONE WITHOUT THE APPROVAL OF
THE DESIGNER; CONSULT DESIGNER AND/OR HIS
2 LOCATION PLAN REPRESENTATIVE ON THIS REGARD.
1 3 SCALE NTS

REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GLENN A. DALAPO
REGION - X Engineering Assistant
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE REHABILITATION OF MULTI-PURPOSE
SITE DEVELOPMENT PLAN RAEMAN BHEE M. APUGAN HAROLD C. CAERMARE RONALD T. GEMPISAO P 20
BUILDING (COVERED COURT)
DESIGNED: MARIVEL FRANCES L. ONG, A.E.R.
LOCATION PLAN Engineer II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. PANABOL, KINOGUITAN, MISAMIS ORIENTAL PLUMBING NOTES
JEAN R. TIOZON DATE: DATE: DATE: DATE: 1 3 22
Brgy. 26, Gingoog City
Engineer II/Master Plumber
1 2 3 4 5 6
30000

5000 5000 10000 5000 5000

HATCH AREA SHOWING


SCOPE OF WORK FOR
THIS PROJECT
EXISTING STAGE
PROP. DEMOLITION

3.5mm THK. x 25mm


METAL BEARING STEEL BAR 3.5mm THK. x 25mm
SPACED @ 25mm O.C. STEEL CROSS BAR
1250 1250
DS DS DS DS DS DS

100
B

B
LINE CANAL
TO MAIN DRAINAGE

550

350
100
Ø75mm DS
PEDESTAL

PLAN
3.5mm THK. x 25mm
STEEL CROSS BAR
17000

RAISED FLOOR SLAB 200mm 3.5mm THK. x 25mm


ABOVE NATURAL GROUND METAL BEARING STEEL BAR
SPACED @ 25mm O.C.

4" THK. CHB

400
500
100mm THK. CONCRETE
CANAL

100 350 100

550

SECTION
TO MAIN DRAINAGE
LINE CANAL
A

A
DS DS DS DS DS DS 2 LINE CANAL DETAIL
2 3 SCALE NTS

1 2 3 4 5 6

1 DRAINAGE LAY-OUT
2 3 SCALE 1:100 MTS.

REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GLENN A. DALAPO
REGION - X Engineering Assistant
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE REHABILITATION OF MULTI-PURPOSE
BUILDING (COVERED COURT) DRAINAGE LAY-OUT RAEMAN BHEE M. APUGAN HAROLD C. CAERMARE RONALD T. GEMPISAO MARIVEL FRANCES L. ONG, A.E.R. P 21
CATCH BASIN DETAIL DESIGNED:
Engineer II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. PANABOL, KINOGUITAN, MISAMIS ORIENTAL JEAN R. TIOZON DATE: DATE: DATE: DATE: 2 3 22
Brgy. 26, Gingoog City
Engineer II/Master Plumber
SPECIFICATION :
1. WATER LINES
Polypropylene Pipe & Fitting, Type 3, PN 20
2. DOWN SPOUT
Polyvinyl choride (PVC) series 1000.
6
3. STORM DRAINAGE PIPES
B Interior - Polyvinyl chloride (PVC) series 1000.
5
50
00
GE Exterior - Polyvinyl chloride (PVC) series 1000.
INA
RA Concrete Drain Pip (CDP) ASTM C-76
IND
DS MA
4 0
50
0
TO 4. VENT PIPES/VENT STACK
Polyvinyl chloride (PVC) series 1000.
30 DS
5. SOIL AND WASTE PIPES
00
0
10
Polyvinyl chloride (PVC) series 1000.
00
0
6. VALVES
DS
3 AG
E
Up to 50mmØ B62, 860 Kpa Class, threaded end.
ST E A
ING INAG
IST RA 7. PIPES SEALANT
EX
IND
AL MA Polyvinyl choride - PVC Compound
2 N
50
CA
0
TO
0
E Polypropylene - Joinery by Socket fusion
LIN
DS
DS m 8. DRAINS & CLEANOUTS
1 0m D
50
20 UN
00
ABGRO
All drains & cleanouts shall be cast
S
R AL
L
DS
6 iron body w/ bronze/brass top.
OO UR
FLNAT
DS D
ISE VE
RAABO
DS
5
DS L
NA
CA
LIN
E 4

B
DS

00
0
DS
3
17
KEY TO SYMBOLS
DS
2 WC WATER CLOSET
FD FLOOR DRAIN
LAV LAVATORY
1 CO CLEAN OUT
A VT VENT TRHU
SH SHOWER HEAD
FAU FAUCET
GV GATE VALVE
CB CATCH BASIN
SV SEPTIC VAULT
1 ISOMETRIC DRAINAGELAY-OUT PIPES LINE
3 3 SCALE 1:100 MTS. WATER LINE
M WATER METER
AV ANGLE VALVE

REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GLENN A. DALAPO
REGION - X Engineering Assistant
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE REHABILITATION OF MULTI-PURPOSE
BUILDING (COVERED COURT) ISOMETRIC LAY-OUT RAEMAN BHEE M. APUGAN HAROLD C. CAERMARE RONALD T. GEMPISAO MARIVEL FRANCES L. ONG, A.E.R. P 22
SPECIFICATION DESIGNED:
Engineer II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. PANABOL, KINOGUITAN, MISAMIS ORIENTAL JEAN R. TIOZON DATE: DATE: DATE: DATE: 3 3 22
Brgy. 26, Gingoog City
Engineer II/Master Plumber