You are on page 1of 2

Dispositivo: Ascon M9 Servo

Applicazione: Regolazione valvola modulante gas per per controllo temperatura o valvola
motorizzata in raffreddamento forno o riscaldamento essiccatoio
Ingresso Applicato: Termocoppia K o S
Macchine interessate: Forni ed Essiccatoi in linea al forno
Data : 22/02/2005

C.PaS = 11 Per entrata in configurazione (C.PaS = 33 : Impostazione di fabbrica) (CS121195)


TC K Risc. TC S Risc. TC K Raff. TC S Raff. TC K Risc. Ess. TC K Raff.
(AL2 = Marcia Bruc) (AL1=Dev.H)
Conf InP : (AL2=Dev.H)
InP. TC K TC S TC K TC S TC K TC K
SC.dd - - - - - -
Sc.Lo - - - - - -
Sc.Hi - - - - - -
S9r - - - - - -
CHar - - - - - -
Unit oC oC oC oC oC oC
Conf S.P. :
rS.P.C. Loc Loc Loc Loc Loc Loc
rS.In - - - - - -
S.P.tM P.Min P.Min P.Min P.Min P.Min P.Min
St.MO 2 2 2 2 2 2
Conf Out :
O.Ity U.Rev U.Rev U.dir U.dir U.Rev U.dir
H.C.OP - - - - - -
S.Out 0 0 100 100 0 100
rtH none none none none none none
O.r.ty - - - - - -
rt.Lo - - - - - -
rt.Hi - - - - - -
OP2 - - - - - -
Conf L.Inp :
IL1 OFF OFF OFF OFF OFF OFF
IL2 OFF OFF OFF OFF OFF OFF
St.IL 0 0 0 0 0 0
Conf ALM :
AL1 dev.H dev.H dev.H dev.H dev.H dev.H
A1Ou OP3 OP3 OP3 OP3 OP3 OP3
Ltch no no no no no no
bloc no no no no no no
AL2 OFF FS.H OFF OFF dev.H dev.H
A2Ou - OP4 - - OP4 OP4
Ltch - no - - no no
bloc - no - - no no
AL3 OFF OFF OFF OFF OFF OFF
AL4 OFF OFF OFF OFF OFF OFF
Conf EHit : Per uscire dalla configurazione
TC K Risc. TC S Risc. TC K Raff. TC S Raff. TC K Risc. Ess. TC K Raff.
(AL2 = Marcia Bruc) (AL1=Dev.H)

Menu S.P : AccS = hide (AL2=Dev.H)


S.P. 1 (hide) 0 0 0 0 0 0
S.P. 2 (hide) 0 0 0 0 0 0
SSEL (hide) none none none none none none
S.P. L (hide) 0 0 0 0 0 0
S.P. H (hide) 1200 1250 1200 1200 1200 1200
S.L. u (hide) 6 6 OFF OFF OFF OFF
S.L. d (hide) 6 6 OFF OFF OFF OFF
rtio - - - - - -
biaS - - - - - -
SP. SL (hide) 0 0 0 0 0 0
SL.uF (hide) 6 6 OFF OFF OFF OFF
SL.dF (hide) 6 6 OFF OFF OFF OFF
L - c (hide) Com Com Com Com Com Com
Menu AL : AccS = read
1deH (Fast) 30 30 30 30 10 20
2FSH (read) - 1220 - - 30 30
hy.1u (hide) 2 2 2 2 2 2
hy.1d (hide) 2 2 2 2 2 2
St 1 (hide) no no no no no no
Sic 1 (hide) no no no no no no
tF 1 (hide) 5 5 5 5 5 5
hy.2u (hide) - 2 - - 2 2
hy.2d (hide) - 2 - - 2 2
St 2 (hide) - no - - yeS no
Sic 2 (hide) - yeS - - no no
tF 2 (hide) - 30 - - 5 5
Menu PId : AccS = hide
P.b. (Fast) 3.0 3.0 3.0 3.0 3.0 3.0
t.i. (Fast) 90 90 90 90 90 90
t.d. (Fast) 5.0 5.0 5.0 5.0 5.0 5.0
d.Err (hide) 0.5 0.5 0.5 0.5 0.5 0.5
O.C. (hide) - - - - - -
MreS (hide) OFF OFF OFF OFF OFF OFF
Menu tunP : AccS = hide
tunP (hide) no no no no no no
Menu In. : AccS = hide
t.FiL (hide) 2.0 2.0 2.0 2.0 2.0 2.0
In.Sh (hide) 0 0 0 0 0 0
t.SaM (hide) 0.5 0.5 0.5 0.5 0.5 0.5
Menu Out : AccS = hide
OP L (hide) 0.0 0.0 0.0 0.0 0.0 0.0
OP H (hide) 100.0 100.0 100.0 100.0 100.0 100.0
OPr (hide) OFF OFF OFF OFF OFF OFF
StOP (hide) OFF OFF OFF OFF OFF OFF
MU.tM (Fast) 40 40 40 40 40 40
MU.hy (hide) 1.0 1.0 1.0 1.0 1.0 1.0
Menu CoMM : AccS = read
Addr (Altr) 1-127 1-127 1-127 1-127 1-127 1-127
baud (hide) 4800 4800 4800 4800 4800 4800
Prot (hide) JbuS JbuS JbuS JbuS JbuS JbuS
Menu AccS : A.PaS = 99 per entrare (A.PaS = 11 : Impostazione di fabbrica)
AcLe OPer Oper Oper Oper Oper Oper
E.Amn yes yes yes yes yes yes
C.PaS 11 11 11 11 11 11
A.PaS 99 99 99 99 99 99

You might also like