This document describes several instruments used in a process including an RTD PT 100 temperature sensor suitable for wide temperature measurement, a pump to circulate hot water, a manual valve to prevent fluid flow during maintenance, a pH sensor to separate solutions after mixing, a control valve to regulate temperature in a reaction tank, and a float switch level sensor to measure and ensure sufficient water levels in a heating tank.
This document describes several instruments used in a process including an RTD PT 100 temperature sensor suitable for wide temperature measurement, a pump to circulate hot water, a manual valve to prevent fluid flow during maintenance, a pH sensor to separate solutions after mixing, a control valve to regulate temperature in a reaction tank, and a float switch level sensor to measure and ensure sufficient water levels in a heating tank.
This document describes several instruments used in a process including an RTD PT 100 temperature sensor suitable for wide temperature measurement, a pump to circulate hot water, a manual valve to prevent fluid flow during maintenance, a pH sensor to separate solutions after mixing, a control valve to regulate temperature in a reaction tank, and a float switch level sensor to measure and ensure sufficient water levels in a heating tank.
to measured temperature in this project. RTD PT 100 RTD PT100 provides high (Resistance accuracy measurement of Temperature temperature. Detector) It has a wide temperature range, typically from (-200°C to 600°C), making it suitable for use in various industrial applications. easy to use and does not require any special calibration or adjustment.
Pump used to push hot water
to jacket tank for heating purpose.
Pump
Used as a safety equipment in
our process to prevent flow of fluids in emergency situations or during maintenance. Also, can avoiding from fluid pressure drop and turbulence Manual Valve can be minimised. (Gate Valve) Purpose using the pH sensor is to separate the solution that form after mixing process. Help in separated the solution automatically. pH Sensor
To control the manipulated
variable in the control loop for the reaction tank's oil temperature. As a last instrument in the closed loop to achieve the Control desired value. Valve (Globe Valve)
This type of sensor very
suitable and reliable in measuring level in our heating tank. Level It can sensing the level Sensor measurement even though (Float high or low. Switch Also act as a safety instrument Sensor) to prevent the heating tank from water drought and damaged.