Cement Pastes
(Required for determining Normal Consistency & Setting Time)
1. Place the dry paddle and the dry bowl in the mixer.
3. Add the cement to the water and allow 30 s for the absorption
of the water.
5. Stop the mixer for 15 s and during this time scrape down into
the batch any paste that may have collected on sides of the
bowl.
Note:
• Wash the paddle and mixing bowl immediately after usage.
• Wash the Vicat accessories (conical ring, needles / plunger, glass plate).
• Wash the scoop, spatula, measurement buckets and graduated cylinder.
• Clean your work place.
Data Sheet
(a) Normal Consistency, (b) Initial Setting Time & (c) Final Setting Time
3 27 175.5 650
Note:
Draw the graph (water content % on x-axis and penetration on y-axis) to show the effect of water on normal
consistency.
(b) Initial Setting Time:
Diameter of Needle = 1 mm
Target: First find Normal Consistency. Then Change the needle. Then find Penetration of 25 mm or less (every time
allow to penetrate for 10 sec) with 15 min of interval.
Take readings at different location (approx. 5 – 10 mm away from previous point or edge of the ring).
Note:
Draw the graph (time on x-axis and penetration on y-axis) to find the exact initial setting time.
(c) Final Setting Time:
Diameter of Needle = 1 mm & Circular ring at the bottom.
Target: First find Normal Consistency & Initial Setting Time. Then Change the needle. Then find Penetration until
complete circular impression is NOT VISIBLE (every time allow to penetrate for 10 sec) with 5 min of interval.
Take readings at different location (approx. 5 – 10 mm away from previous point or edge of the ring).