Professional Documents
Culture Documents
Titanium healing abutments page 10 Multi-unit screw retained abutment drill guide page 39
Open tray impression transfers page 11 Single unit and bridge screw retained restorations page 42
Instruments page 56
2
ESTHETIC LINE implant
International presence
With production and management based in Italy, C-Tech
Implant is however active in all major world markets and is
distributed in over 33 countries.
Scientific research,
advanced technology and simplification
C-Tech Implant differentiates itself with attention to
research and the application of high technology to its
products, all while maintaining a simplicity of insertion and
ease of use.
Mission statement
The goal of C-Tech Implant is to provide the highest
level of quality for technologically advanced products at
reasonable prices in order to allow the dental practitioner
to find solutions for the broadest range of patients.
3
ESTHETIC LINE implant characteristics
4
ESTHETIC LINE implant
Bevelled Shoulder
Micro Grooving
Double
Lead Thread
Thread in Thread
Groove in Groove
Aggressive Apical
Design
Rounded Apex
5
Purity and precision
6
ESTHETIC LINE implant
Precision components
abutment
no gap
implant
7
Dental Implants
E G
EL implant ø3.8
EL implant ø4.3
8
ESTHETIC LINE implant
EL implant ø5.1
EL implant ø6
EL implant ø7
9
Titanium healing abutments
Cover screws L H
H L D item#
1.8 5.5 BL-4305
2.8 6.5 BL-4305/1 BL-4305 BL-4305/1 BL-4305/2 BL-4305/3
3
3.8 7.5 BL-4305/2
4.8 8.5 BL-4305/3
L
C
EL CEC titanium healing abutments ø4.5
D Fixture C item#
L
3 2 EL-4502HT
4 3 EL-4503HT
4.5 EL-4502HT EL-4503HT EL-4504HT EL-4506HT
5 4 EL-4504HT h2 h3 h4 h6
7 6 EL-4506HT
L
C
EL CEC titanium healing abutments ø5.5
D Fixture C item#
L
3 2 EL-5502HT
4 3 EL-5503HT
5.5 EL-5502HT EL-5503HT EL-5504HT EL-5506HT
5 4 EL-5504HT h2 h3 h4 h6
7 6 EL-5506HT
Protruding Standard/Flush
Cover Screw Cover Screw
10
ESTHETIC LINE implant
L1
L2
L1
Open tray impression post Includes BL-5050L
C
L1 L2 D C item#
11.6 - 4.5 5.55 EL-4544L
12.3 - 4.5 4.3 EL-4544S
EL-4544S EL-4544L BL-5050S BL-5050L
10 25.7 3 - BL-5050L Short Long
6 21.7 3 - BL-5050S
D
Material: Titanium grade 5
D
L
Analog
L D
11.5 4
Material: Titanium grade 5
BL-5143
11
Closed tray impression transfers
L D C Fixture item#
1 EL-4501F D
2 EL-4502F
EL-4501F EL-4502F EL-4503F EL-4504F* EL-4506F*
6 4.5 3 EL-4503F h1 h2 h3 h4 h6
4 EL-4504F
6 EL-4506F
L D C Fixture item#
2 EL-5502F
D
3 EL-5503F
7 5.5 EL-5502F EL-5503F EL-5504F* EL-5506F*
4 EL-5504F h2 h3 h4 h6
6 EL-5506F
L
EL CEC PEEK ø4.5 abutments/transfers Includes prosthetic screw
C
L D C Fixture item#
2 EL-4502P
3 EL-4503P
5.7 4.5 EL-4502P EL-4503P EL-4504P* EL-4506P*
4 EL-4504P h2 h3 h4 h6
6 EL-4506P
L D
6 6.5
EL-4547
Note: together with the EL-4547 impression cap, the EL temporary PEEK and EL titanium abutments can be used as closed tray impression transfers.
Material: PEEK
12
ESTHETIC LINE implant
L item#
13.5 EL-4541M
8.2 EL-4541MS
EL-4541M EL-4541S EL-5051M EL-5051S
Medium Short
Note: intended use for single tooth only - set inlcudes post and screw
Material: Titanium grade 5
D
L1 L2
Non engaging closed tray transfers Includes screw and impression cap (BL-4546)
C
L1 L2 D C Fixture item#
12.8 3.0 EL-4540L
4 2.87
10.3 0.5 EL-4540
EL-4540L EL-4540
Material: Titanium grade 5 Long Short
L D
5 4
BL-4546
Note: together with the BL-4546 impression cap, the EL temporary PEEK and EL titanium abutments can be used as closed tray impression transfers.
Material: PEEK
D
Internal prosthetic screws
L
L D item#
10 2.5 BL-5052HX
10.5 2.25 EL-5052HXL
BL-5052HX EL-5052HXL
Standard For abutment
TIGHTENING: with torque ratchet 25 Ncm lenghts 4 and
Material: Titanium grade 5 6 mm
13
Open tray transfer
Analog
BL-5143
Guide screw
For open tray impression post
BL-5050L BL-5050S
Long Short
14
ESTHETIC LINE implant
Intended use
Open tray impression technique.
Characteristics
- Slender emergence profile accommodates space
limitations.
- Guide screw can be tightened either by hand or with the
prosthetic driver.
- High precision impression components give an exact
replica of the intraoral situation. 1
- Clear-cut tactile response from the prosthetic connection
verifies proper seating of components.
Note
Open tray impression procedure requires a custom-made
tray with perforations. Impression posts are intended for
single use only to ensure optimal fit and precise impression
taking for each patient.
STEP 1 2
Place the impression post accurately into the implant and
hand-tighten the guide screw.
STEP 2
Make perforations in the custom-made impression tray
(light cured resin) according to the individual situation so
that the positioning screw of the impression post sticks
out.
STEP 3 3
Take the impression using an elastomeric impression
material (polyvinyl siloxane or polyether rubber).
STEP 4
Reposition and fix the analog in the impression using the
screw.
15
Closed tray transfers
Analog
BL-5143
PEEK Transfers EL CEC titanium Non engaging transfers Closed tray capless
EL PEEK abutments together EL Titanium Abutments together BL-4546 PEEK Impression Cap impression post
with the snap on EL-4547 cap with the snap on EL-4547 cap and BL-5052HX
function as impression transfers function as impression transfers Short Screw are included in the set
EL-4502P EL-4501F EL-5502F EL-4540 EL-4540L EL-4541S EL-4541M
EL-4503P EL-4502F EL-5503F Short Long Short Medium
EL-4504P* EL-4503F EL-5504F*
EL-4506P* EL-4504F* EL-5506F*
EL-4506F*
Screw Screw
BL-5052HX EL-5052HXL BL-5052HX EL-5052HXL
Short Long Short Long
16
ESTHETIC LINE implant
Intended use
Closed tray impression technique.
Characteristics
- Slender emergence profile to accommodate space
limitations.
- No additional preparation (i.e. perforation) of tray
required.
- High precision impression components giving an exact
replica of the intraoral situation. 1
- Clear-cut tactile response from the prosthetic connection
verifyng proper seating of components.
Note
Impression posts ensure optimal fit and precise impression
taking for each patient. 2
STEP 1
Place the impression post accurately into the implant and
hand-tighten the prosthetic screw.
STEP 2 3
Push the impression cap on the top of the impression
transfer.
STEP 3
Take the impression using an elastomeric impression
material (polyvinyl siloxane or polyether rubber).
STEP 4
Use a standard impression tray.
STEP 5 4
Mount the impression transfer on the analog using the
screw (ref. EL-5052HXL - BL-5052HX).
STEP 6
Reposition the impression transfer in the tray. Push the
impression transfer until you feel that the tip of the transfer
is completely and firmly reseated into the impression cap. 5
17
Technical planning abutments
L D C Fixture item#
1 EL-401 D
2 EL-402 EL-401 EL-402 EL-403 EL-404* EL-406*
6 4.5 3 EL-403 h1 h2 h3 h4 h6
4 EL-404
6 EL-406
Material: Alluminium
L D C Fixture item#
2 EL-502
D
3 EL-503
7 5.5 EL-502 EL-503 EL-504* EL-506*
4 EL-504 h2 h3 h4 h6
6 EL-506
Material: Alluminium
L D C Fixture G item#
1 EL-1501 D
2 EL-1502 EL-1501 EL-1502 EL-1503 EL-1504*
7.75 4.5 15°
3 EL-1503 h1 h2 h3 h4
4 EL-1504 Over angle
Material: Alluminium
L D C Fixture G item#
1 EL-2501 D
2 EL-2502 EL-2501 EL-2502 EL-2503 EL-2504*
7.6 4.5 25°
3 EL-2503 h1 h2 h3 h4
4 EL-2504 Over angle
Material: Alluminium
Intended use
Extra-oral planning of prosthetic restoration.
Characteristics
- Color-coded planning abutments.
- Comprehensive planning set containing all planning
abutments arranged clearly.
- Proper seating of planning abutments verified through the 1
clear-cut response from the prosthetic connection.
- Planning abutments fabricated of sterilizable material.
Step 1
Place the planning abutment into the technical lab model
situation in order to plan and choose the appropriate
titanium abutment in cost effective manner.
2
Step 2
Place the titanium abutment and hand-tighten the screw.
Step 3
Prepare the titanium abutment and modify it as required.
Step 4
Fabricate the superstructure on the modified abutment
using the standard modelling, casting and veneering 3
methods.
Step 5
Cast the framework using the standard casting methods.
Step 6
Veneer the superstructure.
4
19
Titanium abutments
Intended use
Cement-retained restorations.
Characteristics Note
- Concave esthetic concept (CEC) abutments allow the The cement margin must not be more than 2 mm below the
maintenance of the maximum amount of gingival volume mucosa. Use a new basal screw for the final insertion of the
around the abutment. The CEC helps to provide a gingival abutment.
seal against the bacteria in the oral cavity as well as to
promote a natural emergence profile.
- Less grinding necessary due to prepared mucosa margins.
- Adaptation to natural soft tissue contour due to prepared
mucosa margins in different heights (H1, H2, H3, H4, H6).
- Reliable.
- Morse locking connection: Abutment and implant are joined
together so as to form a single fused unit.
- Extractor system allows easy abutment removal from the
implant or the analog.
L D C Fixture item#
1 EL-4501F D
2 EL-4502F
EL-4501F EL-4502F EL-4503F EL-4504F* EL-4506F*
6 4.5 3 EL-4503F h1 h2 h3 h4 h6
4 EL-4504F
6 EL-4506F
L D C Fixture item#
2 EL-5502F
D
3 EL-5503F
7 5.5 EL-5502F EL-5503F EL-5504F* EL-5506F*
4 EL-5504F h2 h3 h4 h6
6 EL-5506F
20
ESTHETIC LINE implant
L D C Fixture G item#
1 EL-151
D
2 EL-152
7.75 4.5 15° EL-151 EL-152 EL-153 EL-154*
3 EL-153 h1 h2 h3 h4
4 EL-154 Over angle
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5
G
L D C Fixture G item#
1 EL-251 D
2 EL-252
7.6 4.5 25° EL-251 EL-252 EL-253 EL-254*
3 EL-253 h1 h2 h3 h4
4 EL-254 Over angle
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5
L
Castable chrome cobalt base Includes casting cylinder and prosthetic screw BL-5052HX
L D
5 4.2
21
CAD-CAM Components
L
Titanium CEREC® bases Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-5052HX
C
L D C Fixture item#
1 BL-6047
BL-6047 BL-6047H2 BL-6047H3
4.65 4.25 2 BL-6047H2
h1 h2 h3
3 BL-6047H3
L D
6.55 4.8
BL-6047/1 BL-6047/2
Material: Plastic for Omnicam for Bluecam
L D C Fixture item#
1 EL-6041
5 4.2 2 EL-6042 EL-6041 EL-6042 EL-6043
3 EL-6043 h1 h2 h3
L D C Fixture item#
1 EL-6041R EL-6041R EL-6042R EL-6043R
5 4.2 2 EL-6042R h1 h2 h3
3 EL-6043R
22
ESTHETIC LINE implant
L
Casting cylinders for titanium bases
L D
4.2 9.1
Non rotating scan body Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-5052HX
L L1 D item#
11.7 - 4.8 EL-6040P
Intra-oral scan body Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes a prosthetic screw L1
L L1 D item#
12 4 6 EL-6070
L
Scan cap Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw EL-SCANSCREW
L D
12 5.6
EL-6044PR EL-6044P
TIGHTENING: with torque ratchet 15 Ncm PEEK PEEK
per basi per basi
Material: PEEK EL-6041R EL-6041
EL-6042R EL-6042
EL-6043R EL-6043
23
D
L
Digital scan analog Available for EXOCAD, 3SHAPE and DENTALWINGS - Included prosthetic screw DG-SCREW
L D
11.5 4
DG-SCREW EL-DG5143
TIGHTENING: with torque ratchet 20 Ncm included
D
Internal prosthetic screw
L
L D item#
10 2.5 BL-5052HX
L D
7.5 2.4 EL-SCANSCREW
MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051 L
L D
10 5.2
EL-MUASCANP
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK
D
Short MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051
L
L D
5 5.2
EL-MUASCANS
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK
24
ESTHETIC LINE implant
L
3D MUA analog Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw DG-SCREW
L D
14 5
DG-SCREW EL-DG5146
included
TIGHTENING: with torque ratchet 20 Ncm
Material: Titanium grade 5
D1
MUA bases Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-6051 L
L D1 D2 item# D2
5 EL-DG4526S
4 5.8 EL-DG4526S EL-DG4526L
8 EL-DG4526L
Bridge screw L
L D
3.5 2
D1
L
SSR Scan Cap Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw SSR-50.52
L D1 D2
16 4.2 4.6
D2
TIGHTENING: Bridge screw torque 15 Ncm SSR-SCAN
Material: PEEK
25
Temporary abutments
D
L
EL CEC PEEK ø4.5 abutments Includes prosthetic screw
C
L D C Fixture item#
2 EL-4502P
3 EL-4503P
5.7 4.5 EL-4502P EL-4503P EL-4504P* EL-4506P*
4 EL-4504P h2 h3 h4 h6
6 EL-4506P
L D
6 6.5
EL-4547
Note: together with the EL-4547 Impression Cap, the EL temporary PEEK and titanium abutments can be used as closed tray impression transfers.
Material: PEEK
D1
L D1 D2
7.8 3.59 4.5 D2
Note: Together with the EL-4543 Temp-Cap, the EL temporary PEEK abutments can be used to temporarily stabilize a prosthesis. EL-4543
Material: PEEK
26
ESTHETIC LINE implant
Prosthetic extractor L
L
14.2
L
Latch driver prosthetic extractor
L
34.25
L D
8.61 8
Finger Extractor
L D
36 8 L
Material: Stainless steel
CT-9026
27
O-Ball attachment system D1
L
O-ball abutment and MUA driver
L D1 D2
19.3 7.9 4.8
D2
Material: Titanium grade 5 BL-0600
L
O-ball abutments
C
L D C Fixture item#
1 BL-5641
2 BL-5642
3.7 4
3 BL-5643
BL-5641 BL-5642 BL-5643 BL-5645
5 BL-5645
O-ball analog L
L D
11.5 4
Material: Titanium grade 5 BL-5144
D D
L D o-ring D
3.5 4.7 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4
D D
L D item# o-ring D
x5 x10 x25
3.2 4.2 MCH-2 3.8
2.9 4 MCH-3 MCH-2 MCH-3 MC-3005 MC-3005/10 MC-3005/25
medium hard O-RING O-RING O-RING
Material: Titanium grade 5 Material: FDA Buna 5 pieces 10 pieces 25 pieces
28
ESTHETIC LINE implant
Intended use
Removable dentures retained by implants in the mandible
and maxilla.
Characteristics
- The clinical process for the O-ball attachment is quick,
easy and functional.
- The O-ring attachment is designed to virtually eliminate
wear on the O-ball abutment and minimize the need for
maintenance.
- 4 different gingival heights.
- 3 different grades of resistance provided by the combination
of different o-rings and housings which offer the most suitable
retention for each situation.
Note
Dual retention for optimal abutment-denture connection.
Excellent long-term performance due to wear resistant
components.
STEP 1
Screw the spherical abutment into the implant using the
torque ratchet (25 Ncm) and the driver (ref. BL-0600).
STEP 2
Rebase the overdenture according to standard procedure.
STEP 3 1
Use a laboratory burr to relieve the denture base in the
indicated areas.
29
Anchor abutment system
CE marked products by Rhein83
D
Metal housing 2 pieces
L
L D
1.98 4.5 x2
Material: Titanium grade 5 141CAE
D
Caps 4 pieces
L
L D
1.78 3.8 x4 x4 x4 x4
Material: 140CEV - kepital 140CEV 140CET 140CER 140CEG
140CET/140CER/140CEG - pebax strong standard soft extra-soft
retention 2.7kg retention 1.8kg retention 1.2kg retention 0.6kg
D1
D2
Anchor abutment
L
L D1 D2 item#
1 134BL1
2 134BL2
3 134BL3 134BL1 134BL2 134BL3 134BL4 134BL5 134BL6
4.3 2.5
4 134BL4 h1 h2 h3 h4 h5 h6
5 134BL5
6 134BL6
30
ESTHETIC LINE implant
145SAE
Laboratory accessories
D
Processing caps - black 4 pieces
L
L D
1.78 3.8 x4
Material: Rilsan 140CEN
L
L D
9 3.7 x2
Material: Acetal 144MTE
144AVC4
31
D1
D2
L D1 D2
15.6 4.3 2.5 x2
Material: Stainless steel AISI 303 144AE
L D
5.5 4.6
Material: Stainless steel AISI 303 044CAIN
D
Castable cap
L
L D
2.45 3.8
Material: Crystal polystyrene 151SS
L1
D2 D1
OT-Equator square screw driver for abutment L2
L1 L2 D1 D2
774CHE
17 10.5 9 3.5 square
Material: Stainless steel 1.25 mm
L
OT-Equator square latch driver for abutment D
L D
760CE
22 2.3
32
ESTHETIC LINE implant
Straight abutments L
C
L D C item#
1 BL-4750/1
2 BL-4750/2
2.5 5 3 BL-4750/3 BL-4750/1 BL-4750/2 BL-4750/3 BL-4750/4 BL-4750/5
4 BL-4750/4
h1 h2 h3 h4 h5
5 BL-4750/5
L
17° angled abutments Includes internal screw BL-5052MUA C2
C1 D
L D C1 C2 G item#
1 2.5 BL-1750/1 D
2 3.5 BL-1750/2
BL-1750/1 BL-1750/2 BL-1750/3 BL-1750/4 BL-1750/5 BL-1750/6
3 4.5 BL-1750/3 h1 h2 h3 h4 h5 h6
2.5 5.5 17°
4 5.5 BL-1750/4
5 6.5 BL-1750/5
6 7.5 BL-1750/6
Over angle
TIGHTENING: with torque ratchet 25 Ncm
Bridge screw torque 10 Ncm
Material: Titanium grade 5 G
L D C1 C2 G item#
1 3.5 BL-3050/1 D
2 4.5 BL-3050/2
BL-3050/1 BL-3050/2 BL-3050/3 BL-3050/4 BL-3050/5 BL-3050/6
3 5.5 BL-3050/3 h1 h2 h3 h4 h5 h6
2.5 5.5 30°
4 6.5 BL-3050/4
5 7.5 BL-3050/5
6 8.5 BL-3050/6
Over angle
33
D
Healing cap L
L D
5.7 5
D1
D1
L
Open tray transfer Includes screw BL-7012
L
L D1 D2 item#
10.5 4.2 5 BL-7011 D2
15 2.1 - BL-7012
BL-7011 BL-7012
Material: Titanium grade 5 screw
D1
L D1 D2
8 4.2 5 D2
Material: Titanium grade 5 BL-7010
Multi-unit analog
L
L D
14.7 5
Material: Titanium grade 5 BL-5146
34
ESTHETIC LINE implant
D1
L
Temporary titanium abutment Includes bridge screw BL-6051
L D1 D2
12 3.5 5
D2
TIGHTENING: with torque ratchet 15 Ncm BL-4526
Material: Titanium grade 5
D1
L
Castable abutment Includes bridge screw BL-6051
L D1 D2
12.45 3.3 4.6 D2
Material: Plexiglass
MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051 L
L D
10 5.2
EL-MUASCANP
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK
D
Short MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051
L
L D
5 5.2
EL-MUASCANS
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK
35
D
L
3D MUA analog Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw DG-SCREW
L D
14 5
DG-SCREW EL-DG5146
TIGHTENING: with torque ratchet 20 Ncm included
D1
MUA bases Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-6051
L D1 D2 item# D2
5 EL-DG4526S
5.8 4 EL-DG4526S EL-DG4526L
8 EL-DG4526L
Bridge screw L
L D
3.5 2 BL-6051
L D
8.6 2.2
36
ESTHETIC LINE implant
BL-7013
D1
L
O-ball, MUA and SSR abutments driver
L D1 D2
19.3 7.9 4.8
D2
Material: Stainless steel BL-0600
37
Screw retained restorations
STEP 1
Fabricate the stone model including analogs and gingival
mask.
STEP 2
Place and screw the castable abutments onto the
protruding multi-unit analogs.
Shorten the cylinders down to the height of the occlusal 1
plane.
STEP 3
Remove the gingiva modeling material to permit easy
access for submucosal contouring and verification of
component seating. Wax-up the bridge framework to
appropriate dimensions. The layer of wax must have
sufficient thickness to avoid the wrong coefficient of
thermal expansion and a negative effect on porcelain firing. 2
STEP 4
Prepare the wax-up for investing and casting procedures.
STEP 5
Attach the resulting framework to the models and create
final prosthesis.
STEP 6 3
Passively fit the resulting prosthesis onto the abutments.
38
ESTHETIC LINE implant
Characteristics
- Durable titanium construction.
- Adjustable and foldable, allowing to be parallel to and
follow the contour of the crestal bone. 1
- Sterilizable.
STEP 1
Make a 2.0 pilot hole in order to place the guide pin.
STEP 2
After placement of the guide pin into the drilled site,
the angle and position of the guide band can be adjusted 2
to be parallel to the crestal bone.
STEP 3
The titanium band can be bent in order to follow the arch of
the crestal bone.
STEP 4
Three different angulations are indicated on the outside
of the guide, 0°, 17° and 30°. These angulations match
the angulations of the different C-TECH multi-unit screw
retained abutments. 3
STEP 5
Placement of the screw retained abutments.
EL-3017 5
39
Closed tray technique
Patient procedure
STEP 1
Remove the healing abutments.
STEP 2
Screw the abutment into the implant.
STEP 3
1
Screw each closed tray transfer onto the protruding
abutments.
STEP 4
Take the impression using an elastomeric impression
material (polyvinyl siloxan or polyether rubber).
STEP 5
Remove the closed tray transfer from the abutment.
2
STEP 6
Screw onto the abutments the healing cap screws so as
to keep the soft tissue in place until the final prosthesis is
completed.
40
ESTHETIC LINE implant
Laboratory procedure
STEP 1
Screw the closed tray transfer
onto the analog.
STEP 2
Reposition the transfer into the previously taken impression
material being sure that the transfers are properly seated.
1
STEP 3
Master model.
41
Single unit and bridge screw retained restorations
D1
SSR Abutment GH
GH D item#
1 SSR-4710
2 SSR-4720
4.6 SSR-4710 SSR-4720 SSR-4730 SSR-4740
3 SSR-4730
4 SSR-4740
D
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5
L
SSR Comfort Cap Includes prosthetic screw SSR-50.52
L D
6.5 4.5
Material: PEEK
D1
L
SSR Transfer Includes prosthetic screw SSR-50.52
L D1 D2
9.3 2.89 4.6
D2
Material: Titanium grade 5 SSR-POST
D1
L
SSR Scan Cap Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw SSR-50.52
L D1 D2
16 4.2 4.6
D2
TIGHTENING: with torque ratchet 15 Ncm SSR-SCAN
Material: PEEK
42
ESTHETIC LINE implant
D1
L
SSR Analog
L D
12 4.6
D1
L
SSR Casting Cylinder The complete set includes prosthetic screw SSR-50.52
L D1 D2
9 3.7 4.6
D2
Material: Acrylic
L
SSR Bridge screw
L
6.8 SSR-50.52
L
O-ball, MUA and SSR abutments driver
L D1 D2
19.3 7.9 4.8
D2
Material: Titanium grade 5 BL-0600
43
Bar system D1
L
Multi-unit analog
L D
14.7 5
D
OT-Bar
L D
23 2 x2
Material: Polystyrene Shockproof ABS 0220BB
D
L D item#
x4 x4
027CRR
5 3
027CRG
026CRR 027CRG
Material: Rylsan
Soft Medium
D1
L
Castable abutment Includes bridge screw BL-6051
L D1 D2
12.45 3.3 4.6 D2
Material: Plexiglass
44
ESTHETIC LINE implant
STEP 1
Place the castable multi-unit abutments on the analogs and
tighten the bridge screws.
STEP 2
Make height adaptations according to the individual
situation.
1
STEP 3
Use a residue-free burn-out plastic to fix the bar segments
to the castable abutments.
STEP 4
The clips are fixed into the prosthesis.
45
One Time System
L D C Fixture item#
5.5 2 EL-ONE TIME GS2 EL-ONETIME GS2 EL-ONETIME GS3
4.5 h2 h3
6.5 3 EL-ONE TIME GS3
EL-ONETIME-CS
L D
6.75 4.5
EL-ONETIME-BASE2 EL-ONETIME-BASE3
TIGHTENING: with torque ratchet 25 Ncm must be used must be used
Note: The height of the base does not change, only the height of the screw varies with EL-ONETIME GS2 with EL-ONETIME GS3
Material: Titanium grade 5
46
ESTHETIC LINE implant
Transfer cap L
L D
6.5 8 EL-ONETIME-CAP
Material: PEEK
Laboratory analog L
L D
12.5 4.5
Holder
EL-ONETIME-HOLDER
47
D2
L D1 D2
11.5 3.7 4.5
D1
TIGHTENING: Bridge screw torque 20 Ncm EL-ONETIME-DG DG-SCREW BL-5052MUA
Material: Titanium grade 5 included included
L D
6.55 4.8
BL-6047/1 BL-6047/2
Material: Plastic for Omnicam for Bluecam
48
ESTHETIC LINE implant
Surgical protocol
STEP 1
The Gingival sleeve is placed in the implant and fastened
into the implant with the fixation screw.(25NCM)
The top of the sleeve will be approx. 1mm beneath the top
of the gingiva. 1
STEP 2
The cover screw will be placed and tightened into the
gingival sleeve finishing at a level flush with the top of the
gingival. (10NCM)
STEP 3
During the healing process, the gingival will close around
and attach itself to the gingival sleeve. 2
Prosthetic protocol
STEP 1
Once healed, the cover of the gingival sleeve is removed and
the base is placed into the gingival sleeve.
The base is fastened into the gingival sleeve with the
fixation screw (25NCM)
1
STEP 2
The reconstruction is made onto the base with no need to
remove the gingival sleeve.
49
Surgical Kit EL-SUR.KIT.01
Locator Pilot drill Paralleling pins Main drills Depth stops EL hard bone drills Counterbore
drill CT-1720E CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N EL-3138 / EL-4351
CT-2020 CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N
CT-STOP10
EL/BL implant Implant Hex Prosthetic Extractor ND implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 ratchet extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 ND-E7001 CT-2000
BL-E7001L CT-8052 ND-E7001L
50
ESTHETIC LINE implant
Locator Pilot drill Depth gauges Combined Paralleling pins Main drills Depth stops EL hard bone drills Adapter Counterbore
drill CT-1720E CT-E9007 depth CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N CT-E7002 EL-3138 / EL-4351
CT-2020 CT-E9008 paralleling pins CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N CT-E7003
CT-E9010 CT-PIN1 CT-STOP10 / CT-STOP01 / CT-STOP02
EL/BL implant Implant Hex Prosthetic Extractor ND O-ball EL MUA and ND implant ND Implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 driver O-ball driver ratchet latch extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 MC-3003M BL-0600 ND-E7001 ND-E9040 CT-2000
BL-E7001L CT-8052 ND-E7001L
The Drills CT-1760E, CT-1770E, EL-1760N and EL-1770N are not included in the kit but can be purchased separately.
51
EL Prosthetic Kit PRSKIT01
EL MUA and Extractor Hex driver Latch extractor Prosthetic latch ND O-ball
O-ball driver BL-6060 CT-9025S BL-6061 BL-9019 driver
BL-0600 MC-3003M
* * * * *
Torque wrench
CT-8010
52
ESTHETIC LINE implant
53
Drill Stop Kit
STOPKIT01 Contents
Stop L.6 - CT-STOP06
Stop L.7 - CT-STOP02
Stop L.8 - CT-STOP01
Stop L.9 - CT-STOP07
Stop L.10 - CT-STOP03
Stop L.11 - CT-STOP08
Stop L.12 - CT-STOP12
Stop L.13 - CT-STOP09
Stop L.14 - CT-STOP14
Stop L.15 - CT-STOP10
Kit Contents
Ratchet
Ratchet extender
Latch driver adapter
Locator drill
1.4 mm Drill
2.0 mm Osteotome
2.3 mm Osteotome
2.6 mm Osteotome
3.1 mm Osteotome
3.3 mm Osteotome
3.8 mm Osteotome
4.0 mm Osteotome
4.2 mm Osteotome
4.5 mm Osteotome
54
ESTHETIC LINE implant
55
Instruments D2
L3
L1
L1 L2 L3 D1 D2
23.5 16.5 5.5 1.9 2.5 D1
Material: Titanium grade 5 CT-PIN1
1.9 mm
2.5mm
D2
L3
L1
L2
Paralleling pin
L1 L2 L3 D1 D2 x2
24.2 14.2 10.2 2 2.6 D1
CT-9003
Material: Titanium grade 5 1.6 mm
2.0mm
M4
L M3
M2
Depth gauges M1
L D M1 M2 M3 M4 item#
3 CT-E9007 D
18.5 3.8 7 9 11 13 CT-E9008
CT-E9007 CT-E9008 CT-E9010
4.6 CT-E9010
Material: Titanium grade 5
L item# L
10.8 BL-E7001
17.8 BL-E7001L
BL-E7001 BL-E7001L
Material: Stainless steel
56
ESTHETIC LINE implant
L1
Implant latch With retention
L
L L1 item#
16 30 BL-E9040L
11.8 25.15 BL-E9040
BL-E9040L BL-E9040
L1
Locator drill
L1 L2 D L2
29 15 1.6
L1
Pilot drill L2
L1 L2 D
35.2 17.2 2.1
CT-1720E
Material: Stainless steel
L
Drill extender
L
25
Note: This item is intended as a drill extender and will not support more than 40Ncm. It is not intended as an implant driver extension. CT-2000
57
D
L
Stops L1
L1 L D item#
13.1 6. 4 CT-STOP06
12.1 7. 4 CT-STOP02
11.1 8. 4 CT-STOP01 CT-STOP06 CT-STOP02 CT-STOP01 CT-STOP07 CT-STOP03 CT-STOP08 CT-STOP12 CT-STOP09 CT-STOP14 CT-STOP10
10.1 9. 4 CT-STOP07 Stop L.6 Stop L.7 Stop L.8 Stop L.9 Stop L.10 Stop L.11 Stop L.12 Stop L.13 Stop L.14 Stop L.15
9.1 10. 4 CT-STOP03
5.2
8.1 11. 4 CT-STOP08
7.1 12. 4 CT-STOP12
6.1 13. 4 CT-STOP09
5.1 14. 4 CT-STOP14
4.1 15. 4 CT-STOP10
Intended use: Main drills diameter 2.1 mm, 3.5 mm, 4.3 mm. D
Material: Titanium grade 5
Stops XL L1
L1 L D item#
9. 4 7. 4 XLSTOP-07
8. 4 8. 4 XLSTOP-08
8. 3 XLSTOP-07 XLSTOP-08 XLSTOP-10 XLSTOP-12
6. 4 10. 4 XLSTOP-10
Tope L.07 Tope L.08 Tope L.10 Tope L.12
4. 4 12. 4 XLSTOP-12
Main drills L
L D Fixture item#
3.3 CT-1735E D
19.2 4 CT-1743E
CT-1735E CT-1743E CT-1751E CT-1760E CT-1770E
4.8 CT-1751E
6.0 CT-1760E
17
6.5 CT-1770E
Counterbore L
L D Fixture item#
3.1 EL-3138 D
27.5
4.3 EL-4351
EL-3138 EL-4351
Material: Titanium grade 5
58
ESTHETIC LINE implant
Bone Taps
L
L D Fixture codice#
3.8 EL-TAP38 D
12 4.3 EL-TAP43
EL-TAP38 EL-TAP43 EL-TAP51
5.1 EL-TAP51
L D Fixture codice#
item#
3.45 EL-1735N D
18.66 4.1 EL-1743N
EL-1735N EL-1743N EL-1751N EL-1760N EL-1770N
4.9 EL-1751N
5.7 EL-1760N
16.7
6.75 EL-1770N
Hex drivers
L
L item#
9.8 CT-9025XS
26 CT-9025S
CT-9025XS CT-9025S CT-9025
32 CT-9025
L
Prosthetic latch driver
L
26.5
Material: Stainless steel BL-9019
59
Torque wrench attachments
L item# L
12.5 CT-8051
18.5 CT-8052
CT-8051 CT-8052
Material: Stainless steel
Prosthetic extractor L
L
14.2
Material: Stainless steel BL-6060
ND O-ball driver
L L
8
Material: Stainless steel MC-3003M
L
Latch driver prosthetic extractor
L
34.25
60
ESTHETIC LINE implant
Finger adapter
L D item#
5.8 12.7 CT-E7002
8.61 8 CT-E7003
CT-E7002 CT-E7003
Material: Stainless steel for ratchet for latch
drivers drivers
CT-8010
61
Site preparation D2/D3
CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-E9007 EL-3138 BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill Depth Gauge Counterbore Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (outer 3.1mm) latch driver ratchet driver
Optional in case of
hard cortical bone 40Ncm 40Ncm
ø3.8
5 mm
ø1.6
CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-E9008 EL-4351 BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill Depth Gauge Counterbore Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer 3.9mm) latch driver ratchet driver
Optional in 40Ncm 40Ncm
ø4.3 case of hard
cortical bone
5 mm
ø2.15
CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-1751E CT-E9010 EL-4351 BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill 5.1mm Drill Depth Gauge Counterbore Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) (outer Ø4.6mm) latch driver ratchet driver
Optional in
case of hard 40Ncm 40Ncm
ø5.1 cortical bone
5 mm
ø3.05
*Depth: Minimum 1mm deeper than the length of implant to allow for subcrestal seating.
To avoid bone overheating, set the cutting speed between 100 and 750rpm.
Note: an additional 0.4 mm must be added to the lenght of the drill due to the lenght of the cutting tip.
62
ESTHETIC LINE implant
15.5 mm
15 mm
11.5 mm
11 mm
9.5 mm
9 mm
7.5 mm
7 mm
0 mm
-0.4 mm
63
Site preparation D2/D3
CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-1751E CT-1760E BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill 5.1mm Drill 6.0mm Drill Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) (outer Ø4.6mm) (outer Ø5.5mm) latch driver ratchet driver
40Ncm 40Ncm
ø6.0
5 mm
ø2.5
CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-1751E CT-1760E CT-1770E BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill 5.1mm Drill 6.0mm Drill 7.0mm Drill Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) (outer Ø4.6mm) (outer Ø5.5mm) (outer Ø6.5mm) latch driver ratchet driver
40Ncm 40Ncm
ø7.0
5 mm
ø3.4
*Depth: Minimum 1mm deeper than the length of implant to allow for subcrestal seating.
To avoid bone overheating, set the cutting speed between 100 and 750rpm.
Note: an additional 0.4 mm must be added to the lenght of the drill due to the lenght of the cutting tip.
64
ESTHETIC LINE implant
D1 additional steps
EL-1760N BL-E9040
6.0mm Implant latch driver
hard bone drill
40Ncm
EL-1770N BL-E9040
7.0mm Implant latch driver
hard bone drill
40Ncm
65
Implant packaging
2221 EL-
Implant dimension
3.8 L. 8 mm
EL-Dental implant D.
66
ESTHETIC LINE implant
1 2 3
4 5 6
7 8 9
67
English version
REV. 12 / 07-2022
Go to Follow us
2
NARROW DIAMETER implant
International presence
With production and management based in Italy, C-Tech
Implant is active in all major world markets and is
distributed in over 33 countries.
Scientific research,
advanced technology and simplification
C-Tech Implant differentiates itself with attention to
research and the application of high technology to its
products, all while maintaining a simplicity of insertion and
ease of use.
Mission statement
The goal of C-Tech Implant is to provide the highest
level of quality for technologically advanced products at
reasonable prices in order to allow the dental practitioner
to find solutions for the broadest range of patients.
3
ND IMPLANT characteristics
Bevelled shoulder
- Facilitates bone growth above the shoulder Double lead thread
- Long term implant stability - Insertion rate of 1,5mm per rotation
- Biological repartition of the forces in cortical bone - Guarantees primary stability
- Increased bone to implant contact
Conical connection - Faster and even insertion while protecting bone
structure
- Structural strength stability
- Reduction of micro-movement
Thread in thread / groove in groove
- Increased bone to implant contact
Micro grooving
- Softens forces to the cortical bone during insertion
- Facilitates cortical bone maintenance
Platform switching
- Reduces bone loss
- Better representation of the biological width
Sandblasted surface
- Promotes long term esthetic stability
- Best surface for osseo integration and bone to implant
contact
Indexing hex
Aggressive apical design - Antirotational security
- Ideal for immediate implant placement
- Guarantees primary stability
Rounded apex
- Promotes the protection of the sinus floor, nerve canal
and other important anatomical structures during
insertion
4
NARROW DIAMETER implant
Bevelled Shoulder
Micro Grooving
Double
Lead Thread
Groove in Groove
Aggressive Apical
Design
Rounded Apex
5
Dental Implants
ND implant ø3.1
Healing Abutments L
C
L D C Fixture item#
0.7 2 ND-3022
1 3.8 4 ND-3024
ND-3022 ND-3024 ND-3026
1.5 6 ND-3026
Cover Screw L
L
5.8
ND-3008
TIGHTENING: with torque ratchet 10 N=Ncm 0.8mm
Material: titanium grade 5
Prosthetic screw L
L
7.7
6
NARROW DIAMETER implant
L
Open tray transfer Includes screw ND-3041
C
L D C
ND-3040
7.5 3.8 2
Material: titanium grade 5
L
Impression post screw
L
20
ND-3041
TIGHTENING: with torque ratchet 20 N=Ncm
Material: titanium grade 5
Analog L
L D
15 3.1
Material: titanium grade 5 ND-3042
7
Closed tray impression transfer
L D
5 4
Material: plastic BL-4543
L
Complete set
C
L D C
11.5 3.8 2
Titanium abutments
D1
L D1 D2 C Fixture item#
D2
1 ND-3025/1
8 3.8 4 2 ND-3025/2
ND-3025/1 ND-3025/2 ND-3025/3
3 ND-3025/3 h1 h2 h3
L D C Fixture G item#
1 ND-1530/1 D
6 4 2 15° ND-1530
ND-1530/1 ND-1530 ND-1530/3
3 ND-1530/3 Over flat h1 h2 h3
8
NARROW DIAMETER implant
L D C Fixture G item#
1 ND-2530/1 D
6 4 2 25° ND-2530/2
ND-2530/1 ND-2530/2 ND-2530/3
3 ND-2530/3 Over flat h1 h2 h3
L D C
7.5 3.8 2 ND-5830
L D1 D2 C
D2
8 3.8 4 1
ND-TEMP
TIGHTENING: with torque ratchet 20 N=Ncm
Material: PEEK
Prosthetic screw L
L
7.7
9
CAD CAM components
D
L D C
4.65 4.25 2 ND-6047
L D
6.55 3.9
BL-6047/1S BL-6047/2S
Material: Plastic for Omnicam for Bluecam
L D C Fixture item#
1 ND-6041
5 3.8 2 ND-6042 ND-6041 ND-6042 ND-6043
3 ND-6043 h1 h2 h3
L D C Fixture item#
1 ND-6041R
5 3.8 2 ND-6042R ND-6041R ND-6042R ND-6043R
3 ND-6043R h1 h2 h3
D
TIGHTENING: with torque ratchet 20 Ncm
Material: Titanium grade 5
Intraoral scanbody Compatible with EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw ND-5052HX
L D
9.45 3.8
ND-6040
NON ROTATING
TIGHTENING: with torque ratchet 20 Ncm
Material: PEEK
10
NARROW DIAMETER implant
L
Scan cap Compatible with EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw ND-SCANSCREW
L D
12 4.8
ND-6044P ND-6044PR
NON ROTATING ROTATING
TIGHTENING: with torque ratchet 15 Ncm
D
Material: PEEK
3D Analog Compatibile with EXOCAD, 3SHAPE e DENTALWINGS - Includes prosthetic screw DG-SCREW
L D
11.5 3.2
DG-SCREW ND-DG5143
included
TIGHTENING: with torque ratchet 15 Ncm
Material: Titanium grade 5
Prosthetic screw L
L
7.7
ND-5052HX
TIGHTENING: with torque ratchet 20 Ncm
Material: titanium grade 5
Scan screw L
L D
6.1 3
ND-SCANSCREW
11
Flat abutments
D
L1
Flat abutments
L
L L1 D item#
8.1 2 FLAT2
9.1 3 4.5 FLAT3
FLAT2 FLAT3 FLAT4
10.1 4 FLAT4 h2 h3 h4
L item# L
9.85 FLAT-DRIVER
L1 L2 D
7.2 4 4.5
FLATHEALING
Material: titanium grade 5
D
L D
11.2 3.74
Material: titanium grade 5 FLATPOST
D
L D
6.4 2
FLATSCREW
TIGHTENING: with torque ratchet 15 N=Ncm
Material: titanium grade 5
D
Flat analog L
L D
12.5 4
Material: titanium grade 5 FLAT-AN
12
NARROW DIAMETER implant
L D item#
FLAT-CAST
11.5 3.6
FLAT-TIT
FLAT-CAST FLAT-TIT
TIGHTENING: with torque ratchet 15 N=Ncm
Material: Plexiglass and titanium grade 5
L
Flat scan cap Compatible with EXOCAD, 3SHAPE e DENTALWINGS - Includes prosthetic screw FLATSCREW
L D
12 4.5 FLAT-SCAN
Flat Base
L
L D item#
4.5 FLAT-6041S FLAT-6041S FLAT-6041L
4.5
8 FLAT-6041L
L D
11.8 4
Material: titanium grade 5 FLAT-DG
13
O-Ball attachment system
Intended use
Removable dentures retained by implants in the mandible
and maxilla.
Characteristics
- The clinical process for the o-ball attachment system is
quick, easy and functional;
- The O-ring attachment is designed to virtually eliminate
wear on the O-ball abutment and minimize the need for
maintenance;
- 3 different gingival heights;
- 3 different O-ring resistances offering optimal retention
for every individual situation.
Reliable
Dual retention for optimal abutment-denture connection.
Excellent long-term performance due to wear resistant
components.
STEP 1
Screw the spherical abutment into the implant using
butterfly key MC-3002 or ratchet driver
MC-3003S, MC-3003M or MC-3003L.
STEP 2
Rebase the overdenture according to the standard
procedure.
14
NARROW DIAMETER implant
Butterfly driver
D L
L
8.5 7
O-Ball abutments C
L D C item#
1 ND-5641
3.77 3.8 2 ND-5642
3 ND-5643 ND-5641 ND-5642 ND-5643
D D
L D o-ring D
3.5 4.7 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna
soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4
D D
L D item# o-ring D
x5 x10 x25
3.2 4.2 MCH-2 3.8
2.9 4 MCH-3 MCH-2 MCH-3 MC-3005 MC-3005/10 MC-3005/25
medium hard O-RING O-RING O-RING
Material: Titanium grade 5 Material: FDA Buna 5 pieces 10 pieces 25 pieces
15
Anchor abutment system
CE marked products by Rhein83
D
Metal housing 2 pieces
L
L D
1.98 4.5 x2
141CAE
D
Plastic caps 4 pieces
L
L D
1.78 3.8 x4 x4 x4 x4
Material: 140CEV - kepital 140CEV 140CET 140CER 140CEG
140CET/140CER/140CEG - pebax
strong standard soft extra-soft
retention 2.7kg retention 1.8kg retention 1.2kg retention 0.6kg
145SAE
16
NARROW DIAMETER implant
144AVC4
D1
D2
Anchor abutment L
L D1 D2 item#
2.4 130ND31
3.4 130ND32
4.4 4.3 2.5 130ND33 130ND31 130ND32 130ND33 130ND34 130ND35
5.4 130ND34 h1 h2 h3 h4 h5
6.4 130ND35
17
ND Surgical Kit EL-SUR.KIT.01
Locator Pilot drill Paralleling pins Main drills Depth stops EL hard bone drills Counterbore
drill CT-1720E CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N EL-3138 / EL-4351
CT-2020 CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N
CT-STOP10
EL/BL implant Implant Hex Prosthetic Extractor ND implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 ratchet extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 ND-E7001 CT-2000
BL-E7001L CT-8052 ND-E7001L
18
NARROW DIAMETER implant
Locator Pilot drill Depth gauges Combined Paralleling pins Main drills Depth stops EL hard bone drills Adapter Counterbore
drill CT-1720E CT-E9007 depth CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N CT-E7002 EL-3138 / EL-4351
CT-2020 CT-E9008 paralleling pins CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N CT-E7003
CT-E9010 CT-PIN1 CT-STOP10 / CT-STOP01 / CT-STOP02
EL/BL implant Implant Hex Prosthetic Extractor ND O-ball EL MUA and ND implant ND Implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 driver O-ball driver ratchet latch extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 MC-3003M BL-0600 ND-E7001 ND-E9040 CT-2000
BL-E7001L CT-8052 ND-E7001L
The Drills CT-1760E, CT-1770E, EL-1760N and EL-1770N are not included in the kit but can be purchased separately.
19
ND Prosthetic Kit PRSKIT01
EL MUA and Extractor Hex driver Latch extractor Prosthetic latch ND O-ball driver
O-ball driver BL-6060 CT-9025S BL-6061 BL-9019 MC-3003M
BL-0600
* * * * *
Torque wrench
CT-8010
20
NARROW DIAMETER implant
Kit Contents
Ratchet
Ratchet extender
Latch driver adapter
Locator drill
1.4 mm Drill
2.0 mm Osteotome
2.3 mm Osteotome
2.6 mm Osteotome
3.1 mm Osteotome
3.3 mm Osteotome
3.8 mm Osteotome
4.0 mm Osteotome
4.2 mm Osteotome
4.5 mm Osteotome
STOPKIT01 Contents
Stop L.6 - CT-STOP06
Stop L.7 - CT-STOP02
Stop L.8 - CT-STOP01
Stop L.9 - CT-STOP07
Stop L.10 - CT-STOP03
Stop L.11 - CT-STOP08
Stop L.12 - CT-STOP12
Stop L.13 - CT-STOP09
Stop L.14 - CT-STOP14
Stop L.15 - CT-STOP10
21
Laboratory accessories
D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
MC-3013 MC-3014 MC-3014S
4.5 6.4 MC-3014S Temporary O-ball Square head
cap transfer cap transfer cap
Material: POM
Collared analog L
D L
2.6 15.8
D2
Instruments L3
L1
L1 L2 L3 D1 D2
23.5 16.5 5.5 1.9 2.5 D1
L1
Paralleling pin
L2 L3
L1 L2 L3 D1 D2
24.2 14.2 10.2 2 2.6
D2
Material: Titanium grade 5
CT-9003
1.6 mm
2.0mm
22
NARROW DIAMETER implant
L
Drill Extender
L
25
Note: This item is intended as a drill extender and will not support more than 40Ncm. It is not intended as implant driver extension. CT-2000
Material: Stainless steel
L item# L
9.85 ND-E7001
17.75 ND-E7001L
ND-E7001 ND-E7001L
Material: Stainless steel
L L
11.8
Material: Stainless steel ND-E9040
L1
Locator drill
L1 L2 D L2
29 15 1.6
Material: Stainless steel CT-2020
23
L1
Initial drill
L2
L1 L2 D
35.2 17.2 2.1
D
Material: Stainless steel CT-1720E
L1
Main drill L2
L1 L2 D
36.7 15.9 2.6
D
Material: Stainless steel ND-1726E
L1
L2
L1 L2 D
34 15.5 3 D
Material: Stainless steel ND-1731N
L1
L3
Counterbore L2
L1 L2 D2 L3 D3 D2
23.9 4.8 3.1 4.5 3.5 D3
Material: Stainless steel EL-3138
24
NARROW DIAMETER implant
Bone Tap
L
L D
10 3.1 D
Material: Stainless steel EL-TAP31
Stops
L D item#
9 CT-STOP07
11 5.2 CT-STOP08
CT-STOP07 CT-STOP08 CT-STOP09
13 CT-STOP09 Stop L.9 Stop L.11 Stop L.13
Material: Stainless steel
L
26.5
Material: Stainless steel BL-9019
25
Torque wrench attachments
L item# L
12.5 CT-8051
18.5 CT-8052
CT-8051 CT-8052
Material: Stainless steel
Hex drivers
L item# L
9.8 CT-9025XS
12.5 CT-9025S
CT-9025XS CT-9025S CT-9025
18.5 CT-9025
Butterfly driver
D L
L
8.5 7
O-ball driver
L L
8
Material: Stainless steel MC-3003M
26
NARROW DIAMETER implant
Finger adapter L
L D item#
5.8 12.7 CT-E7002
8.61 8 CT-E7003
CT-E7002 CT-E7003
Material: Stainless steel for ratchet for latch
drivers drivers
CT-8010
27
Site preparation D1/D2
5 mm
Site preparation D3
*Depth: Minimum 1mm deeper than length of implant is to allow for subcrestal seating.
To avoid bone overheating, set the cutting speed between 100 and 750rpm.
Note: an additional 0.4 mm must be added to the lenght of the drill due to the leght of the angled cutting tip.
28
NARROW DIAMETER implant
15.5 mm
15 mm
13.5 mm
13 mm
11.5 mm
11 mm
9.5 mm
9 mm
7.5 mm
7 mm
0 mm
-0.4 mm
29
Implant packaging
2221 ND-
Implant dimension
3.1 L. 9 mm
ND-Dental implant D.
30
NARROW DIAMETER implant
1 2 3
4 5 6
7 8 9
31
English version
REV. 08 / 04-2022
Go to Follow us
MONOBLOCK Implant
Implant characteristics page 12
All of the materials produced by C-TECH follow a validated procedure, which includes
surface treatment and packing as well, in conformity with European and international
directives EN ISO 13485, 93/42/EEC and MDR 2017/745 relative to medical devices.
2
SMALL DIAMETER Implant
International presence
With production and management based in Italy, C-Tech
Implant is active in all major world markets and is
distributed in over 33 countries.
Mission statement
The goal of C-Tech Implant is to provide the highest
level of quality for technologically advanced products at
reasonable prices in order to allow the dental practitioner
to find solutions for the broadest range of patients.
3
SMALL DIAMETER Implant
Fine threading
The fine thread SD implants are designed to facilitate the
placement in hard bone.
Implant body
The anatomically shaped implants are produced from
medical grade 5 titanium.
Smooth collar
The top aspect of every collared implant is smooth so as to
better accommodate soft tissue.
Aggressive threading
The aggressive thread for SD Implants are designed for the
added compression and surface area required in soft bone
placement.
4
SMALL DIAMETER Implant
Square Head
O-Ball Head
With collar
With Smooth
Gingival
Collar
Without Collar
Micro Grooving
Fine
Threading
Aggressive
Passivated Threading
Surface
5
Dental Implants
L
D L T C A item#
16.3 10 CAB-10 T
17.8 11.5 CAB-115
1.8 19.3 13 2.5 3.8 CAB-13
21.3 15 CAB-15
24.3 18 CAB-18 D
A
SD Implant ø1.8 fine thread implants
D L T A item# L
13.9 10 NAB-10 T
1.8 16.9 13 3.9 NAB-13
18.9 15 NAB-15
L
D L T C A item#
16.3 10 SAB-10
T
1.8 19.3 13 2.5 3.8 SAB-13
21.3 15 SAB-15
6
SMALL DIAMETER Implant
L
D L T C A item#
16.3 10 IAB-10 T
17.8 11.5 IAB-115
2.1 19.3 13 2.5 3.8 IAB-13
21.3 15 IAB-15
24.3 18 IAB-18 D
A
SD Implant ø2.1 fine thread implants
D L T A item# L
13.9 10 NIAB-10 T
2.1 16.9 13 3.9 NIAB-13
18.9 15 NIAB-15
L
D L T C A item#
16.3 10 SIAB-10
T
2.1 19.3 13 2.5 3.8 SIAB-13
21.3 15 SIAB-15
7
Dental Implant
L
D L T C A item#
16.3 10 MC/25/10
T
2.5 19.3 13 2.5 3.8 MC/25/13
21.3 15 MC/25/15
L
D L T C A item#
16.3 10 MCA/25/10 T
2.5 19.3 13 2.5 3.8 MCA/25/13
21.3 15 MCA/25/15
8
SMALL DIAMETER Implant
L
D L T C A item#
16.3 10 MAB-10
T
19.3 13 MAB-13
2.4 2.5 3.8
21.3 15 MAB-15
24.3 18 MAB-18
D
A
SD Implant ø2.4 aggressive thread implants
D L T A item# L
13.9 10 NMAB-10
T
2.4 16.9 13 3.9 NMAB-13
18.9 15 NMAB-15
L
D L T C A item#
16.3 10 SMAB-10
T
2.4 19.3 13 2.5 3.8 SMAB-13
21.3 15 SMAB-15
9
Prosthetic components
D D
D L O-Ring D
4.7 3.5 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4
D D
D L O-Ring D
x5 x10 x25
4.3 3.1 3.8
MCH-2 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna medium O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-2
Available in packages of 4 caps: MCH-2/4
D D
D L O-Ring D
x5 x10 x25
4 3.1 3.8
MCH-3 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna hard O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-3
Available in packages of 4 caps: MCH-3/4
D
D L
4.3 9.4
D L
4.6 9.3
O-ball temporary and transfer caps For O-ball and square head implants L
D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
MC-3013 MC-3014 MC-3014S
4.5 6.4 MC-3014S Temporary Cap O-ball Transfer Square Head
for O-ball and cap Transfer cap
Material: PEEK
Square Head
10
SMALL DIAMETER Implant
D L
4 6
D
PVC protection
D L L
3.5 4
x5 x10 x25
L
Collared analog
D L
2.6 15.8
L
Non collared analog
D L
2.0 15.8
L
Collared square head analog
D L
2.6 15.8
11
MONOBLOCK Implant
The C-Tech MB, Mono Block Implant, provides 2 different System Compatiblity
prosthetic options as well as 2 different main body designs Choice of tapered and O-ball head prosthetics.
to meet the differing requirements of bone and soft tissue O-ball head is compatible with SD, GL, BL and EL O-ball
encountered in the maxilla and the mandible. attachments
Surface Topography
Blasted main body surface.
Mandibular Apex
Sharp apex to facilitate advancement in D1/D2 bone.
12
MONOBLOCK Implant
Gingival Choice:
Maxilla Type
Gingival Choice:
Gingival Collar
Mandibular Type
Cortical Choice: Gingival Collar
Maxilla Type
Cortical Choice:
Micro Grooving
Mandibular Type
Micro Grooving
Choice Of Main
Choice Of Main Body Threading:
Body Threading: Fine Threading
Agressive for Hard Bone
Threading for
Soft Bone
13
Dental Implants
A
MANOB C
L
D L T C A item#
14.3 9 MANOB-09 T
16.3 11 MANOB-11
3 1.5 3.8
18.3 13 MANOB-13
20.3 15 MANOB-15
MAXOB C
L
D L T C A item#
15.3 9 MAXOB-09 T
17.3 11 MAXOB-11
3 2.5 3.8
19.3 13 MAXOB-13
21.3 15 MAXOB-15
MANTAP C
L
D L T C A item#
15.3 9 MANTAP-09 T
17.3 11 MANTAP-11
3 1.5 4.8
19.3 13 MANTAP-13
21.3 15 MANTAP-15
14
MONOBLOCK Implant
MAXTAP C
L
D L T C A item#
16.3 9 MAXTAP-09 T
18.3 11 MAXTAP-11
3 2.5 4.8
20.3 13 MAXTAP-13
22.3 15 MAXTAP-15
15
Prosthetic components
D D
D L O-Ring D
4.7 3.5 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4
D D
D L O-Ring D
x5 x10 x25
4.3 3.1 3.8
MCH-2 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna medium O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-2
Available in packages of 4 caps: MCH-2/4
D D
D L O-Ring D
x5 x10 x25
4 3.1 3.8
MCH-3 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna hard O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-3
Available in packages of 4 caps: MCH-3/4
D
D L
4.3 9.4
D L
4.6 9.3
O-ball temporary and transfer caps For O-ball and square head implants L
D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
MC-3013 MC-3014 MC-3014S
4.5 6.4 MC-3014S Temporary Cap O-ball Transfer Square Head
for O-ball and cap Transfer cap
Material: PEEK
Square Head
16
MONOBLOCK Implant
D L
4 6
D L item#
4 6.9 MB-3013
MB-3014
2.1 6.5 MB-3013 MB-3014 MB-3006
MB-3006 Tapered Tapered Castable
impression cap temp cap cap
Material: MB-3013 - PEEK
MB-3014 - PEEK
MB-3006 - CPMMA
D
PVC protection
D L L
3.5 4
x5 x10 x25
L
Collared O-ball analog
D L
2.6 15.8
L
Tapered analog
D L
3.1 17.85
17
Instruments L1
L2
SD Drills
D L1 L2 item#
1.1 MC-3001/11 D
14.3
1.3 MC-3001/13
33.3 MC-3001/11 MC-3001/13 MC-3001 MC-3001/20
1.5 MC-3001 single use
17.5
2.0 MC-3001/20
D L
L
8.5 7
SD/MB Adapters
L item#
4 MC-3003S L
8 MC-3003M
MC-3003S MC-3003M MC-3003L
12 MC-3003L Short Medium Long
Material: Stainless steel
L
SD/MB Latch implant driver
D L
3.2 22 D
Material: Stainless steel MC-3020
D L
12 8.6
18
MINI Implant
L1
L1
L2
L2
SD/MB Marking and pilot drills
L1 L2 D item#
D D
29 15 2.1 CT-2020
35.2 17.2 2.1 CT-1720E
CT-2020 CT-1720E
L1
L3
Counterbore L2
L1 L2 D2 L3 D3 D2
23.9 4.8 3.1 4.5 3.5 D3
Material: Stainless steel EL-3138
L1
MB Main drill L2
L1 L2 D
36.7 17.2 2.6
D
Material: Stainless steel ND-1726E
L
MB Drill Extender
L
25
Material: Stainless steel CT-2000
MB Tissue punch
D L
3 2.8 D
Material: Stainless steel TCP-3MM
19
Instrumentation
CT-8010
MC-3018
20
MINI Implant
Locator drill Drill extender Initial drill Drills Main drill Counterbore
CT-2020 CT-2000 CT-1720E MC-3001/11 - MC-3001/13 ND-1726E EL-3138
MC-3001
21
SD Kit MC-00075SC
Drills* Adapters
MC-3001/11 - MC-3001/13 MC-3003S
MC-3001 - MC-3001/20 MC-3003L
* Each surgical kit is equipped with 2 drills; customers can chose drills between ø 1.1 , 1.3, 1.5, 2.0. Customers should communicate the choice of the drills
at the moment of the order.
22
MINI Implant
Torque wrench ND implant Adapters Butterfly driver Prosthetic Hex Tissue punch
CT-8010 ratchet MC-3003M - MC-3003L MC-3002 ratchet driver TCP-3MM
ND-E7001 CT-8051 CT-9025S
ND-E7001L
Locator drill Drill extender Initial drill Depth stops Main drill Counterbore
CT-2020 CT-2000 CT-1720E CT-STOP07 - CT-STOP08 ND-1726E EL-3138
CT-STOP09
23
Surgical Protocol
Case planning
Following evaluation of the patient and the corresponding
panoramic radiographs, the type and number of implants and
planned placement sites are established. There should be a
minimum of 4 implants for mandibular cases and a minimum of 6
for maxilla cases. The implant planning transparency is used to
establish the implant length. A minimum of 5mm between each
implant needs to be maintained to allow space for the housings.
In mandibular cases the implants should be placed starting with a 1
minimum of 5mm anterior of the mental foramen. Following implant
site planning the sites are transferred to the gingiva and marked
with sterile marker or bleeding points.
24
MINI Implant
Prosthetic Protocol
4 5
6 7
8 9
25
Site preparation
3,8 mm 3,8 mm
Insertion Torque:
Insertion Torque:
100 - 750 rpm
2,5 mm
35 - 45 ncm
35 - 45 ncm
2,5 mm
L. 10 mm L. 10 mm
L. 11,5 mm L. 11,5 mm
L. 13 mm L. 13 mm
L. 15 mm L. 15 mm
3,8 mm 3,8 mm
1/3 Length of implant
Insertion Torque:
Insertion Torque:
100 - 750 rpm
2,5 mm
35 - 45 ncm
35 - 45 ncm
2,5 mm
L. 10 mm L. 10 mm
L. 13 mm L. 13 mm
L. 15 mm L. 15 mm
26
SMALL DIAMETER Implant
D1 ADDITIONAL STEPS
Full Length of implant
Insertion Torque:
Insertion Torque:
100 - 750 rpm
35 - 45 ncm
35 - 45 ncm
Insertion Torque:
Insertion Torque:
100 - 750 rpm
35 - 45 ncm
35 - 45 ncm
27
Site preparation
2.3mm
4.8mm
3.8mm
Insertion Torque:
800 - 1000 rpm
ø3.2 ø3.0
35 - 45 ncm
1.5mm 1.5mm
ø3.0 ø3.0
9mm 9mm 4 mm
11mm 11mm
13mm 13mm
15mm 15mm
2.3mm
Full Length of implant
4.8mm
3.8mm
Insertion Torque:
800 - 1000 rpm
35 - 45 ncm
ø3.2 ø3.0
2.5mm 2.5mm
ø3.0 ø3.0
4 mm
9mm 9mm
11mm 11mm
13mm 13mm
15mm 15mm
28
MONOBLOCK Implant
Insertion Torque:
thus for a 13 mm implant, one should drill to the 14 mm.
100 - 750 rpm
15.5 mm
ND-1726E EL-3138 MC-3003S 15 mm
ø 2.6 mm drill ø 3 mm MC-3003M
Counterbore MC-3003L
Ratchet Adapter 13.5 mm
13 mm
11.5 mm
11 mm
7.5 mm
7 mm
Full Length of implant
Insertion Torque:
100 - 750 rpm
35 - 45 ncm
ND-1726E MC-3003S
ø 2.6 mm drill MC-3003M
MC-3003L
Ratchet Adapter 0 mm
-0.4 mm
29
30
MINI Implant
31
English version
REV.05/05-2022
Go to Follow us
3
SURGICAL PROTOCOL
GUIDE POSITIONING
The guide is positioned on the
jaw of the patient, using existing
dentition as stabilizer.
FIXATION PINS
In the case of an edentulous jaw, the
guide is positioned and then fastened
in place using lateral pins.
1B
4
GUIDED SURGERY
RIDGE PROFILER/
FL ATTENER (optional)
In the case that the ridge is sharp,
one can use the ridge flattener
to create a level sur face and
facilitate the use of the locator
drill.
LOCATOR DRILL
The locator drills are used as
a starting point to prevent the
possibility of drill slipping on the
crest.
PILOT DRILL
The 2.1mm pilot drill is used to
perform the osteotomy to its final
depth. To ensure a continuous
engagement with the sleeve during
the initial drilling, the first 2.1mm
pilot drill to be used must be the
shortest one, regardless of the final
length to be achieved. For example,
in a narrow sleeve case, the first is
the drill
GS-N2007 , while in wide sleeve
cases the first one is the drill
GS-W2007.
5
5
SOFT BONE
The 3.5 mm drill will follow the
pilot drill and stop at the same
depth.
HARD BONE
In case of a 3.5mm implant to be
placed in soft bones, the 3.5mm drill
will be the final drill. Instead, in case
of hard bone, the 3.5mm drill will be
followed by the 3.5mm hard bone drill.
IMPL ANT
The implant is removed from the
vial using the implant driver or
implant driver/mount.
6
GUIDED SURGERY
MANUAL DRIVER
Once the implant has been placed
in its site, it can be manually
driven using the finger adapter.
It may also be driven by the
hand-piece using the latch drivers
or by the ratchet through the
adapters or mount/drivers.
10
RATCHET ADAPTERS
The implant latch drivers can be
converted into finger drivers and
into ratchet adapters using the
CT-E7003 finger adapter which fits
onto the top of the latch.
10B
7
OFFSET VARIABILITY
OPTIONS
The GS kit of fers 3 dif ferent of fset
positions on its implant insertion
tools.
In the case that the user needs a
greater distance from the top of
the sleeve to the bone level than
the default 9mm, the GS insertion
tools of fer 2 more options; that of
11mm and 13mm.
11
CORRECT POSITION
The implant is seated in its final
position once the mount shoulder is
flush with the top of the sleeve and
the lines on the top of the shoulder
are aligned with the lines on the top
of the sleeve. These lines represent
the center of the flat sides on the
implant’s internal hex.
12
8
GUIDED SURGERY
x4
GS-NS x10 GS-WS x10
Sleeve for Sleeve for GS-PIN
3.1/3.5 4.3/5.1
x4
GS-LS
GS-FIXDRILL
x2 x4 x4
GS-2000
GS-FIX
Ratchet Driver Long - variable offset Ratchet Driver Long - variable offset
9
Latch Driver
GS-6061
10
GUIDED SURGERY
Narrow Drills
11
Narrow Drills Ø2.1 Narrow Drills Ø3.1 Narrow Drills Ø3.5
L. 7/9/11/13/15 L. 9/11/13/15 L. 9/11/13/15
Narrow Punch
Narrow Profiler
Narrow Locator
Prosthetic Latch
Driver
Extractor
Torque Wrench
Short and Long
Latch Drivers
Long Ø3.1/3.5
12
GUIDED SURGERY
13
Wide Drills
(real Ø4 mm)
GS-W4307 GS-W4307HB GS-W4309 GS-W4309HB GS-W4311 GS-W4311HB GS-W4313 GS-W4313HB GS-W4315 GS-W4315HB
GS-W5107 GS-W5107HB GS-W5109 GS-W5109HB GS-W5111 GS-W5111HB GS-W5113 GS-W5113HB GS-W5115 GS-W5115HB
14
GUIDED SURGERY
Narrow
9mm 9/11/13mm
Offset Offset
Ø3.1
9mm 9/11/13mm
Offset Offset
Ø3.5
Punch Narrow Locator Ø2.1 Ø3.1 Ø3.5 Ø3.5HB Ø3.5 Ø3.5 Ø3.5
Profiler Drill Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet
15
Wide
9mm 9/11/13mm
Offset Offset
Ø4.3
Punch Wide Locator Ø2.1 Ø3.5 Ø4.3 Ø4.3HB Ø4.3/5.1 Ø4.3/5.1 Ø4.3/5.1
Profiler Drill Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet
9mm 9/11/13mm
Offset Offset
Ø5.1
Punch Wide Locator Ø2.1 Ø3.5 Ø4.3 Ø5.1 Ø5.1HB Ø4.3/5.1 Ø4.3/5.1 Ø4.3/5.1
Profiler Drill Drill Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet
16
GUIDED SURGERY
* The kit has the space to accomodate the screw driver EL-3016 and the fixed ratchet MC-00376. These two items are not included in the kit but can be purchased separately.
The torque ratchet CT-8010 is already included in the kit. The latch extractor (GS-6061), the drill for fixing lateral pins (GS-FIXDRILL) and the 3 lateral pins (GS-PIN) are included in the kit.
17
INSTRUMENTS INCLUDED IN THE C-GUIDE KIT
18
C-GUIDE REDUCED KIT GS-SURKIT02
REV. 05/02-2022
Go to Follow us
The C-Bone synthetic bone substitutes line is based on bio-mimetic and nano-
structured hydroxyapatite. C-Bone hydroxyapatite is a calcium phosphate
biomaterial that is very similar to the human bone structure, composition and size
of nano-crystals. The Ca/P ratio of 1.67 is almost identical to that of human bone
apatite. C-Bone is available in 4 different formats: dense granules, porous chips,
injectable paste and moldable crunch, in a wide range of sizes.
C-BONE
GUIDED
TISSUE
REGENE-
RATION
GTR
Moldable Crunch
C-MEMBRANE
Collagen Membranes
CTM-15201 15 x 20 x 0.2 mm 1 pc
CTM-15206 15 x 20 x 0.2 mm 6 pcs
CTM-152010 15 x 20 x 0.2 mm 10 pcs
CTM-20201 20 x 20 x 0.2 mm 1 pc
CTM-120206 20 x 20 x 0.2 mm 6 pcs
CTM-202010 20 x 20 x 0.2 mm 10 pcs
CTM-25251 25 x 25 x 0.2 mm 1 pc
CTM-25256 25 x 25 x 0.2 mm 6 pcs
CTM-252510 25 x 25 x 0.2 mm 10 pcs
CTM-20301 20 x 30 x 0.2 mm 1 pc
CTM-20306 20 x 30 x 0.2 mm 6 pcs
CTM-203010 20 x 30 x 0.2 mm 10 pcs
CTM-30401 30 x 40 x 0.2 mm 1 pc
Excellent bone integration, slow resorption and long stay in the implant site
• Sinus lifts
• Small and large bone increases also in association with autologous grafts,
to limit their resorption
• Filling of extraction sockets
C-BONE X
REV. 02 / 11-2021
3
Advantages
4
1 ONE TIME CLEVER Concept
5
Step 1
Measure + Calculate
The aim of the concept is to maintain the thickest possible
gingiva. A height of 3 mm is considered to be ideal. The
implant should be placed 1 mm subcrestally.
Step 2
Implantation
1 2
Instead of raising a flap, in most
cases the surgical procedure
will be initiated by using a tissue
punch to create a mucotomy. (Pic
1)
3 4 5
6
1 ONE TIME CLEVER Concept
GS-WPUNCH CT-2020 CT-1720E NND-1726E CT-1735E CT-1743E BL-E7001L EL-ONE TIME GS2/ EL-ONE TIME GS2/ EL-ONETIME-BASE
Wide punch Locator Drill 2.0mm Drill 3.1 mm drill 3.5 mm Drill 4.3 mm Drill Implant EL-ONE TIME GS3 EL-ONE TIME GS3 Titanium Base
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) ratchet driver Titanium healing Titanium healing
abutment abutment
ø4.3
5 mm
ø2.15
Step 3
The gingival sleeve is placed in the implant and fastened with the cover screw.
The final position of the cover screw is slightly below the level of the gingiva.
The cover screw is tightened to 30 Ncm, then loosened again and then tightened
to 15 Ncm.
Explanation There is a Morse taper connection between the implant and the
abutment. Therefore, the cover screw must be tightened to the final position so
that the gingival sleeve can be placed into the final position.
7
Healing phase
During the healing phase, the gingiva forms around the healing screw, bonding
tightly.
Step 4 (post-healing)
Prosthetics
After complete healing, the cover screw is removed. No anesthesia is required for
the impression.
8
1 ONE TIME CLEVER Concept
Recall should be done and checked and, if necessary, the internal screws should
be re-tightened to 30Ncm.
Digital/Conventional Impression
Digital Impression
Conventional Impression
9
Pros
• Up to 30 degrees of divergence
30°
10
1 ONE TIME CLEVER Concept
L D C Fixture item#
5.5 2 EL-ONE TIME GS2 EL-ONETIME GS2 EL-ONETIME GS3
4.5 h2 h3
6.5 3 EL-ONE TIME GS3
Titanium Base L
L D
6.75 4.5
EL-ONETIME-BASE
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5
Transfer cap L
L D
6.5 8
EL-ONETIME-CAP
Material: PEEK
L
Laboratory analog
L D
12.5 4.5
Holder
EL-ONETIME-HOLDER
11
CAD-CAM Components
D
L
Titanium CEREC® bases Includes prosthetic screw BL-5052HX
C
L D C Fixture item#
1 BL-6047
BL-6047 BL-6047H2 BL-6047H3
4.65 4.25 2 BL-6047H2
H1 H2 H3
3 BL-6047H3
L D
6.55 4.8
BL-6047/1 BL-6047/2
Material: Plastic for Omnicam for Bluecam
L D C Fixture item#
1 EL-6041
5 4.2 2 EL-6042 EL-6041 EL-6042 EL-6043
3 EL-6043 H1 H2 H3
L D C Fixture item#
1 EL-6041R EL-6041R EL-6042R EL-6043R
5 4.2 2 EL-6042R H1 H2 H3
3 EL-6043R
12
English version
REV. 01/02-2022
Go to Follow us