You are on page 1of 184

ESTHETIC LINE implant

Implant characteristics page 04 Anchor abutment system page 30

Purity and precision page 06 Laboratory accessories page 31

Precision components page 07 Anchor system instruments page 32

Dental Implants page 08 Full arch screw retained restorations page 33

Titanium healing abutments page 10 Multi-unit screw retained abutment drill guide page 39

PEEK healing abutments page 11 Closed tray technique page 40

Open tray impression transfers page 11 Single unit and bridge screw retained restorations page 42

Closed tray impression transfers page 12 Bar system page 44

Technical planning abutments page 18 One Time System page 46

Titanium abutments page 20 EL Surgical Kit page 50

CAD CAM components page 22 EL Metal Kit page 51

Temporary abutments page 26 EL Prosthetic Kit page 52

Abutment extractor screw page 27 EL Planning Kit page 51

O-Ball attachment system page 28 Drill Stop Kit page 53

Bone Expander Kit page 54

Healing Screw Organizer page 55

Instruments page 56

Site preparation page 62

Explanation of drill marking page 63

Implant packaging page 66

Implant labeling page 66

Implant vial protocol page 67


All of the materials produced by C-TECH follow a validated procedure, which includes
surface treatment and packing as well, in conformity with European and international
directives EN ISO 13485, 93/42/EEC and MDR 2017/745 relative to medical devices.

2
ESTHETIC LINE implant

Dental precision solutions


C-Tech Implant is a dynamic company with aggressive
growth, producing components and product lines primarily
for dental implantology.

International presence
With production and management based in Italy, C-Tech
Implant is however active in all major world markets and is
distributed in over 33 countries.

Scientific research,
advanced technology and simplification
C-Tech Implant differentiates itself with attention to
research and the application of high technology to its
products, all while maintaining a simplicity of insertion and
ease of use.

C-Tech Implant combines the latest trends in implantology


with practical surgical and prosthetic solutions aimed at
offering the practitioner and the patient optimal results.

High quality standards


C-Tech Implant products are made to the highest standards
governing the manufacturing and management of European
medical and dental components.
Up to date audits and certifications assure that these
standards are vigilantly maintained.

Training and advice


Dental professionals are assisted by the wide knowledge
and experience of C-Tech Implant personnel and through
C-Tech courses and training sessions.
During these courses the professional is able to learn the
latest methods of implant placement and reconstruction.

Mission statement
The goal of C-Tech Implant is to provide the highest
level of quality for technologically advanced products at
reasonable prices in order to allow the dental practitioner
to find solutions for the broadest range of patients.

3
ESTHETIC LINE implant characteristics

Bevelled shoulder Thread in thread / groove in groove


- Facilitates bone growth above the shoulder - Increased bone to implant contact
- Long term implant stability
- Biological repartition of the forces in cortical bone Concave esthetic concept
- Non surgical thickening of the peri-implantary tissue
Micro grooving - Facilitates the papilla reconstruction technique
- Softens forces to the cortical bone during insertion
- Facilitates cortical bone maintenance Platform switching
- Reduces bone loss
Triple acid etched surface topography - Better representation of the biological width
- Best surface for osseointegration and bone to implant - Promotes long term esthetic stability
contact
One connection for all 5 diameters
Aggressive apical design - Simplifies the system
- Ideal for immediate implant placement - Reduces inventory
- Guarantees primary stability - Ease of use

Rounded apex Cold weld seal


- Promotes the protection of the sinus floor, nerve canal - Prevents bacterial infiltration of the implant/prosthetic
and other important anatomical structures during connection and consequent bone loss
insertion
Morse locking conical connection
Subcrestal seating - Eliminates micro-movements
- Hinders exposure of the implant through bone resorption - Reduces the risk of screw loosening
- Ideal for the esthetic zone
- Long term esthetic stability Indexing hex
- Provides antirotational security
Three different threading profiles
- Thread designs adapted to different bone structures
that occur along the lenght of the implant
- Enhanced surface area
- Round but cutting apex design

Double lead thread


- Insertion rate of 1.5mm per rotation
- Guarantees primary stability
- Increased bone to implant contact
- Faster and even insertion while protecting bone
structure

4
ESTHETIC LINE implant

Bevelled Shoulder

Micro Grooving

Double
Lead Thread

Thread in Thread

Groove in Groove

Aggressive Apical
Design

Rounded Apex

Concave Platform Cold Weld Seal Morse Locking Indexing Hex


Esthetic Concept Switching Conical
Connection

5
Purity and precision

Material purity and surface treatment


Material purity starts with the acquisition of raw
material from only the most reliable sources of
which each lot is accompanied by its own material
certificate and is completely traceable at all phases
of production and later use. The production facility in
which all the implants and components are made is
owned and operated by C-TECH and is certified to the
highest standards governing the production of dental/
medical devices. To maintain these standards, regular
and independent audits are performed by the German
auditor, TUV Süd. All up to date certificates are Magnification images 50x 200μm
available for download on the company’s website.
The machining of the EL implant is an intricate process
due to the precision required for the Morse conical
connection and the exterior complexity of the implant.
This intricacy requires double the machining time that
would be necessary for that of an average implant.
Throughout and following each step of the production
process, the implants are thoroughly cleaned in 5
seperate cleaning stages, consisting of a total of 20
cleaning cycles. This attention to cleanliness is in
order to assure that no risk of any production residue
is remaining on the implant surface.
Magnification images 200x 100μm
The surface topography is created through a patented
acid etching process. The adjacent photos made with
a scanning electron microscope (SEM) demonstrate
the lack of impurities on the implant surface as well
as the abundant surface area created through the
patented acidification process.
The purity of the grade 4 titanium used for the EL
Magnification images 500x 20μm
implant and the surface topology were independently
verified through an investigation carried out with a
scanning electron microscope (SEM) by the University
of Cologne and Medical Material Research Center of
Berlin, Germany. The investigation demonstrated the
highest level of purity and cleanliness resulting in the
award of the BDIZ quality seal. This investigation is
avaliable in its long form on the C-TECH website. Magnification images 3000x 10μm

Magnification images 20000x 1μm

6
ESTHETIC LINE implant

Precision components

The successful achievement of a Morse lock and


cold weld seal in the implant-prosthetic connection implant
depends on high precision machining. A perfect Morse abutment
connection will result in a structural integrity and
strength that will be as if the 2 parts were fused
together and thus will practically eliminate the gap
fixation screw
between the implant and the abutment. Accordingly,
the C-TECH components are machined to a tolerance
of within 10 microns.
This mechanical fusion of the prosthetic part and
the implant has 2 important benefits: prevention of
the bacterial colonization of the gap, which can lead
Magnification images 50x 200μm
to bone loss around the implant; the elimination of
micro-movements between the implant and abutment
and the consequent screw loosening which can lead to fixation screw
prosthetic failure.
The SEM photos on the right show different
magnifications of the tight abutment and implant
connection. The final photo at the bottom, at 1000 X
magnification, shows a fine line where the abutment abutment
and the implant meet. This practically nonexistent gap
is less than the 1,5 microns width of the bacteria to
be found in the oral cavity.
implant

Magnification images 100x 100μm

abutment

no gap
implant

Magnification images 1000x 10μm

7
Dental Implants

E G

EL implant ø3.8

G 3.8 3.8 3.8 3.8 3.8


A 8 9 11 13 15
B 1.75 1.55 1.55 1.55 1.55
C 0.5 0.5 0.5 0.5 0.5
D 3.3 3.3 4.0 4.0 4.0
E 4.2 5.2 6.5 8.5 10.5
F 1.0 1.0 1.0 1.0 1.0
H 3 3 3 3 3

Material: titanium grade 4 EL-3508 EL-3509 EL-3511 EL-3513 EL-3515


8 mm 9 mm 11 mm 13 mm 15 mm

EL implant ø4.3

G 4.3 4.3 4.3 4.3 4.3


A 7 9 11 13 15
B 2.1 2.1 2.1 2.1 2.1
C 1 1 1 1 1
D 1 2.3 2.3 2.3 2.3
E 5 5.7 7.7 9.7 11.7
F 1.0 1.0 1.0 1.0 1.0
H 3 3 3 3 3
EL-4307 EL-4309 EL-4311 EL-4313 EL-4315
Material: titanium grade 4
7 mm 9 mm 11 mm 13 mm 15 mm

8
ESTHETIC LINE implant

EL implant ø5.1

G 5.1 5.1 5.1 5.1 5.1


A 7 9 11 13 15
B 3.0 3.0 3.0 3.0 3.0
C 1 1 1 1 1
D 1 2.3 2.3 2.3 2.3
E 5 5.7 7.7 9.7 11.7
F 1.0 1.0 1.0 1.0 1.0
H 3 3 3 3 3
EL-5107 EL-5109 EL-5111 EL-5113 EL-5115
Material: titanium grade 4 7 mm 9 mm 11 mm 13 mm 15 mm

EL implant ø6

G 6.0 6.0 6.0


A 7 8 10
B 2.3 2.5 2.5
C 1 1 1
D 1 2.0 2.0
E 5 5 7
F 1.0 1.0 1.0
H 3 3 3
EL-6007 EL-6008 EL-6010
Material: titanium grade 4
7 mm 8 mm 10 mm

EL implant ø7

G 7.0 7.0 7.0


A 7 8 10
B 3.2 3.4 3.4
C 1 1 1
D 1 2.0 2.0
E 5 5 7
F 1.0 1.0 1.0
H 3 3 3
EL-7007 EL-7008 EL-7010
Material: titanium grade 4 7 mm 8 mm 10 mm

9
Titanium healing abutments

Cover screws L H

H L D item#
1.8 5.5 BL-4305
2.8 6.5 BL-4305/1 BL-4305 BL-4305/1 BL-4305/2 BL-4305/3
3
3.8 7.5 BL-4305/2
4.8 8.5 BL-4305/3

TIGHTENING: with torque ratchet 10 Ncm D


Material: titanium grade 5

L
C
EL CEC titanium healing abutments ø4.5

D Fixture C item#
L
3 2 EL-4502HT
4 3 EL-4503HT
4.5 EL-4502HT EL-4503HT EL-4504HT EL-4506HT
5 4 EL-4504HT h2 h3 h4 h6
7 6 EL-4506HT

TIGHTENING: with torque ratchet 10 Ncm


Material: titanium grade 5

L
C
EL CEC titanium healing abutments ø5.5

D Fixture C item#
L
3 2 EL-5502HT
4 3 EL-5503HT
5.5 EL-5502HT EL-5503HT EL-5504HT EL-5506HT
5 4 EL-5504HT h2 h3 h4 h6
7 6 EL-5506HT

TIGHTENING: with torque ratchet 10 Ncm


Material: titanium grade 5

Straight Protruding Cover Screws


The EL implant, with its subcrestal placement, favors
the growth of bone over the platform and even over the
standard cover screw which is flush with the top of
the implant. C-TECH thus offers a choice of protruding
cover screws which hinder bone growth over the screw
top and thus facilitates finding a deeply set implant and
consequent removal of the cover screw.

Protruding Standard/Flush
Cover Screw Cover Screw

10
ESTHETIC LINE implant

Open tray impression transfers D D

L1

L2
L1
Open tray impression post Includes BL-5050L
C

L1 L2 D C item#
11.6 - 4.5 5.55 EL-4544L
12.3 - 4.5 4.3 EL-4544S
EL-4544S EL-4544L BL-5050S BL-5050L
10 25.7 3 - BL-5050L Short Long
6 21.7 3 - BL-5050S
D
Material: Titanium grade 5
D

L
Analog

L D
11.5 4
Material: Titanium grade 5
BL-5143

11
Closed tray impression transfers

EL CEC Titanium ø4.5 abutments/transfers Includes prosthetic screw


C

L D C Fixture item#
1 EL-4501F D
2 EL-4502F
EL-4501F EL-4502F EL-4503F EL-4504F* EL-4506F*
6 4.5 3 EL-4503F h1 h2 h3 h4 h6
4 EL-4504F
6 EL-4506F

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

EL CEC Titanium ø5.5 abutments/transfers Includes prosthetic screw


C

L D C Fixture item#
2 EL-5502F
D
3 EL-5503F
7 5.5 EL-5502F EL-5503F EL-5504F* EL-5506F*
4 EL-5504F h2 h3 h4 h6
6 EL-5506F

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

L
EL CEC PEEK ø4.5 abutments/transfers Includes prosthetic screw
C

L D C Fixture item#
2 EL-4502P
3 EL-4503P
5.7 4.5 EL-4502P EL-4503P EL-4504P* EL-4506P*
4 EL-4504P h2 h3 h4 h6
6 EL-4506P

TIGHTENING: with torque ratchet 25 Ncm


Material: PEEK

PEEK Abutment Impression Cap L

L D
6 6.5

EL-4547
Note: together with the EL-4547 impression cap, the EL temporary PEEK and EL titanium abutments can be used as closed tray impression transfers.
Material: PEEK

*Uses the long screw EL-5052HXL

12
ESTHETIC LINE implant

Closed tray capless impression post L

L item#
13.5 EL-4541M
8.2 EL-4541MS
EL-4541M EL-4541S EL-5051M EL-5051S
Medium Short
Note: intended use for single tooth only - set inlcudes post and screw
Material: Titanium grade 5
D

L1 L2
Non engaging closed tray transfers Includes screw and impression cap (BL-4546)
C

L1 L2 D C Fixture item#
12.8 3.0 EL-4540L
4 2.87
10.3 0.5 EL-4540
EL-4540L EL-4540
Material: Titanium grade 5 Long Short

PEEK Impression Cap L

L D
5 4

BL-4546
Note: together with the BL-4546 impression cap, the EL temporary PEEK and EL titanium abutments can be used as closed tray impression transfers.
Material: PEEK

D
Internal prosthetic screws
L
L D item#
10 2.5 BL-5052HX
10.5 2.25 EL-5052HXL
BL-5052HX EL-5052HXL
Standard For abutment
TIGHTENING: with torque ratchet 25 Ncm lenghts 4 and
Material: Titanium grade 5 6 mm

*Uses the long screw EL-5052HXL

13
Open tray transfer

Analog
BL-5143

Open tray impression post


EL-4544S

Guide screw
For open tray impression post

BL-5050L BL-5050S
Long Short

14
ESTHETIC LINE implant

Intended use
Open tray impression technique.

Characteristics
- Slender emergence profile accommodates space
limitations.
- Guide screw can be tightened either by hand or with the
prosthetic driver.
- High precision impression components give an exact
replica of the intraoral situation. 1
- Clear-cut tactile response from the prosthetic connection
verifies proper seating of components.

Note
Open tray impression procedure requires a custom-made
tray with perforations. Impression posts are intended for
single use only to ensure optimal fit and precise impression
taking for each patient.

STEP 1 2
Place the impression post accurately into the implant and
hand-tighten the guide screw.

STEP 2
Make perforations in the custom-made impression tray
(light cured resin) according to the individual situation so
that the positioning screw of the impression post sticks
out.

STEP 3 3
Take the impression using an elastomeric impression
material (polyvinyl siloxane or polyether rubber).

STEP 4
Reposition and fix the analog in the impression using the
screw.

15
Closed tray transfers

Analog
BL-5143

PEEK Transfers EL CEC titanium Non engaging transfers Closed tray capless
EL PEEK abutments together EL Titanium Abutments together BL-4546 PEEK Impression Cap impression post
with the snap on EL-4547 cap with the snap on EL-4547 cap and BL-5052HX
function as impression transfers function as impression transfers Short Screw are included in the set
EL-4502P EL-4501F EL-5502F EL-4540 EL-4540L EL-4541S EL-4541M
EL-4503P EL-4502F EL-5503F Short Long Short Medium
EL-4504P* EL-4503F EL-5504F*
EL-4506P* EL-4504F* EL-5506F*
EL-4506F*

Screw Screw
BL-5052HX EL-5052HXL BL-5052HX EL-5052HXL
Short Long Short Long

Hex driver Hex driver


CT-9025S CT-9025S

PEEK Abutment Impression Cap PEEK Impression Cap


EL-4547 BL-4546

* Uses the long screw EL-5052HXL

16
ESTHETIC LINE implant

Intended use
Closed tray impression technique.

Characteristics
- Slender emergence profile to accommodate space
limitations.
- No additional preparation (i.e. perforation) of tray
required.
- High precision impression components giving an exact
replica of the intraoral situation. 1
- Clear-cut tactile response from the prosthetic connection
verifyng proper seating of components.

Note
Impression posts ensure optimal fit and precise impression
taking for each patient. 2

STEP 1
Place the impression post accurately into the implant and
hand-tighten the prosthetic screw.

STEP 2 3
Push the impression cap on the top of the impression
transfer.

STEP 3
Take the impression using an elastomeric impression
material (polyvinyl siloxane or polyether rubber).

STEP 4
Use a standard impression tray.

STEP 5 4
Mount the impression transfer on the analog using the
screw (ref. EL-5052HXL - BL-5052HX).

STEP 6
Reposition the impression transfer in the tray. Push the
impression transfer until you feel that the tip of the transfer
is completely and firmly reseated into the impression cap. 5

17
Technical planning abutments

Ø 4.5 straight planning abutments Includes prosthetic screw


C

L D C Fixture item#
1 EL-401 D
2 EL-402 EL-401 EL-402 EL-403 EL-404* EL-406*
6 4.5 3 EL-403 h1 h2 h3 h4 h6
4 EL-404
6 EL-406
Material: Alluminium

Ø 5.5 straight planning abutments Includes prosthetic screw


C

L D C Fixture item#
2 EL-502
D
3 EL-503
7 5.5 EL-502 EL-503 EL-504* EL-506*
4 EL-504 h2 h3 h4 h6
6 EL-506
Material: Alluminium

15° angled planning abutments Includes prosthetic screw


C

L D C Fixture G item#
1 EL-1501 D
2 EL-1502 EL-1501 EL-1502 EL-1503 EL-1504*
7.75 4.5 15°
3 EL-1503 h1 h2 h3 h4
4 EL-1504 Over angle
Material: Alluminium

25° angled planning abutments Includes prosthetic screw


C

L D C Fixture G item#
1 EL-2501 D
2 EL-2502 EL-2501 EL-2502 EL-2503 EL-2504*
7.6 4.5 25°
3 EL-2503 h1 h2 h3 h4
4 EL-2504 Over angle
Material: Alluminium

Complete set of 17 abutments + screws : Ref PLANKIT01


*Uses the long screw EL-5052HXL
18
ESTHETIC LINE implant

Intended use
Extra-oral planning of prosthetic restoration.

Characteristics
- Color-coded planning abutments.
- Comprehensive planning set containing all planning
abutments arranged clearly.
- Proper seating of planning abutments verified through the 1
clear-cut response from the prosthetic connection.
- Planning abutments fabricated of sterilizable material.

Step 1
Place the planning abutment into the technical lab model
situation in order to plan and choose the appropriate
titanium abutment in cost effective manner.
2
Step 2
Place the titanium abutment and hand-tighten the screw.

Step 3
Prepare the titanium abutment and modify it as required.

Step 4
Fabricate the superstructure on the modified abutment
using the standard modelling, casting and veneering 3
methods.

Step 5
Cast the framework using the standard casting methods.

Step 6
Veneer the superstructure.
4

Planning abutment kit 6


PLANKIT01

19
Titanium abutments

Intended use
Cement-retained restorations.

Characteristics Note
- Concave esthetic concept (CEC) abutments allow the The cement margin must not be more than 2 mm below the
maintenance of the maximum amount of gingival volume mucosa. Use a new basal screw for the final insertion of the
around the abutment. The CEC helps to provide a gingival abutment.
seal against the bacteria in the oral cavity as well as to
promote a natural emergence profile.
- Less grinding necessary due to prepared mucosa margins.
- Adaptation to natural soft tissue contour due to prepared
mucosa margins in different heights (H1, H2, H3, H4, H6).
- Reliable.
- Morse locking connection: Abutment and implant are joined
together so as to form a single fused unit.
- Extractor system allows easy abutment removal from the
implant or the analog.

EL CEC Titanium ø4.5 abutments Includes prosthetic screw


C

L D C Fixture item#
1 EL-4501F D
2 EL-4502F
EL-4501F EL-4502F EL-4503F EL-4504F* EL-4506F*
6 4.5 3 EL-4503F h1 h2 h3 h4 h6
4 EL-4504F
6 EL-4506F

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

EL CEC Titanium ø5.5 abutments Includes prosthetic screw


C

L D C Fixture item#
2 EL-5502F
D
3 EL-5503F
7 5.5 EL-5502F EL-5503F EL-5504F* EL-5506F*
4 EL-5504F h2 h3 h4 h6
6 EL-5506F

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

*Uses the long screw EL-5052HXL

20
ESTHETIC LINE implant

EL CEC 15 °angled abutments Includes prosthetic screw


C

L D C Fixture G item#
1 EL-151
D
2 EL-152
7.75 4.5 15° EL-151 EL-152 EL-153 EL-154*
3 EL-153 h1 h2 h3 h4
4 EL-154 Over angle
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5
G

EL CEC 25°angled abutments Includes prosthetic screw


C

L D C Fixture G item#
1 EL-251 D
2 EL-252
7.6 4.5 25° EL-251 EL-252 EL-253 EL-254*
3 EL-253 h1 h2 h3 h4
4 EL-254 Over angle
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5

L
Castable chrome cobalt base Includes casting cylinder and prosthetic screw BL-5052HX

L D
5 4.2

TIGHTENING: with torque ratchet 25 Ncm EL-6041CC

Material: Chrome Cobalt and Plexiglass

*Uses the long screw EL-5052HXL

21
CAD-CAM Components

L
Titanium CEREC® bases Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-5052HX
C

L D C Fixture item#
1 BL-6047
BL-6047 BL-6047H2 BL-6047H3
4.65 4.25 2 BL-6047H2
h1 h2 h3
3 BL-6047H3

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

Scan body for CEREC® bases L

L D
6.55 4.8
BL-6047/1 BL-6047/2
Material: Plastic for Omnicam for Bluecam

Non rotating CEC titanium bases Includes prosthetic screw BL-5052HX


C

L D C Fixture item#
1 EL-6041
5 4.2 2 EL-6042 EL-6041 EL-6042 EL-6043
3 EL-6043 h1 h2 h3

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

Rotating CEC titanium bases Includes prosthetic screw BL-5052HX


C

L D C Fixture item#
1 EL-6041R EL-6041R EL-6042R EL-6043R
5 4.2 2 EL-6042R h1 h2 h3
3 EL-6043R

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

22
ESTHETIC LINE implant

L
Casting cylinders for titanium bases

L D
4.2 9.1

Material: Plexiglass EL-DGCAST EL-DGCAST/R


NON ROTATING ROTATING

Non rotating scan body Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-5052HX

L L1 D item#
11.7 - 4.8 EL-6040P

TIGHTENING: with torque ratchet 25 Ncm EL-6040P


PEEK
Material: PEEK

Intra-oral scan body Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes a prosthetic screw L1

L L1 D item#
12 4 6 EL-6070

TIGHTENING: with torque ratchet 15 Ncm EL-6070


Titanium
Material: Titanium with anti scatter coating

L
Scan cap Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw EL-SCANSCREW

L D
12 5.6
EL-6044PR EL-6044P
TIGHTENING: with torque ratchet 15 Ncm PEEK PEEK
per basi per basi
Material: PEEK EL-6041R EL-6041
EL-6042R EL-6042
EL-6043R EL-6043

23
D

L
Digital scan analog Available for EXOCAD, 3SHAPE and DENTALWINGS - Included prosthetic screw DG-SCREW

L D
11.5 4
DG-SCREW EL-DG5143
TIGHTENING: with torque ratchet 20 Ncm included

Material: Titanium grade 5

D
Internal prosthetic screw
L
L D item#
10 2.5 BL-5052HX

TIGHTENING: with torque ratchet 25 Ncm BL-5052HX


Standard
Material: Titanium grade 5

Screw for scan cap L

L D
7.5 2.4 EL-SCANSCREW

TIGHTENING: with torque ratchet 15 Ncm


Material: Titanium grade 5

MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051 L

L D
10 5.2
EL-MUASCANP
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK

D
Short MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051

L
L D
5 5.2
EL-MUASCANS
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK

24
ESTHETIC LINE implant

L
3D MUA analog Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw DG-SCREW

L D
14 5
DG-SCREW EL-DG5146
included
TIGHTENING: with torque ratchet 20 Ncm
Material: Titanium grade 5

D1

MUA bases Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-6051 L

L D1 D2 item# D2
5 EL-DG4526S
4 5.8 EL-DG4526S EL-DG4526L
8 EL-DG4526L

TIGHTENING: with torque ratchet 15 Ncm


Material: Titanium grade 5

Bridge screw L

L D
3.5 2

TIGHTENING: with torque ratchet 15 Ncm BL-6051

Material: Titanium grade 5

D1

L
SSR Scan Cap Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw SSR-50.52

L D1 D2
16 4.2 4.6
D2
TIGHTENING: Bridge screw torque 15 Ncm SSR-SCAN

Material: PEEK

25
Temporary abutments
D

L
EL CEC PEEK ø4.5 abutments Includes prosthetic screw
C

L D C Fixture item#
2 EL-4502P
3 EL-4503P
5.7 4.5 EL-4502P EL-4503P EL-4504P* EL-4506P*
4 EL-4504P h2 h3 h4 h6
6 EL-4506P

TIGHTENING: with torque ratchet 25 Ncm


Material: PEEK

PEEK Abutment Impression Cap L

L D
6 6.5

EL-4547
Note: together with the EL-4547 Impression Cap, the EL temporary PEEK and titanium abutments can be used as closed tray impression transfers.
Material: PEEK

D1

PEEK glue-on temp cap L

L D1 D2
7.8 3.59 4.5 D2

Note: Together with the EL-4543 Temp-Cap, the EL temporary PEEK abutments can be used to temporarily stabilize a prosthesis. EL-4543

Material: PEEK

*Uses the long screw EL-5052HXL

26
ESTHETIC LINE implant

Abutment extractor screw


As the abutment extractor screw is driven in, it will push the abutment out of the analog or implant.

Prosthetic extractor L

L
14.2

Material: Stainless steel


BL-6060

L
Latch driver prosthetic extractor

L
34.25

Material: Stainless steel BL-6061

Finger/Ratchet adapter for latch drivers L

L D
8.61 8

Material: Stainless steel CT-E7003

Finger Extractor

L D
36 8 L
Material: Stainless steel

CT-9026

27
O-Ball attachment system D1

L
O-ball abutment and MUA driver

L D1 D2
19.3 7.9 4.8
D2
Material: Titanium grade 5 BL-0600

L
O-ball abutments
C

L D C Fixture item#
1 BL-5641
2 BL-5642
3.7 4
3 BL-5643
BL-5641 BL-5642 BL-5643 BL-5645
5 BL-5645

TIGHTENING: with torque ratchet 25 Ncm


Complete set includes:
D
1. O-Ring (Ref. MC-3005) 1 piece
2. Metal Housing (Ref. MCH-2)
3. O-Ball Abutment (Ref. BL-5641, BL-5642, BL-5643, BL-5645)
Material: Titanium grade 5

O-ball analog L

L D
11.5 4
Material: Titanium grade 5 BL-5144

D D

Soft retention caps L

L D o-ring D
3.5 4.7 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4
D D

Medium and hard retention caps L

L D item# o-ring D
x5 x10 x25
3.2 4.2 MCH-2 3.8
2.9 4 MCH-3 MCH-2 MCH-3 MC-3005 MC-3005/10 MC-3005/25
medium hard O-RING O-RING O-RING
Material: Titanium grade 5 Material: FDA Buna 5 pieces 10 pieces 25 pieces

Available in single packages: MCH-2, MCH-3


Available in packages of 4 caps: MCH-2/4, MCH-3/4

28
ESTHETIC LINE implant

Intended use
Removable dentures retained by implants in the mandible
and maxilla.

Characteristics
- The clinical process for the O-ball attachment is quick,
easy and functional.
- The O-ring attachment is designed to virtually eliminate
wear on the O-ball abutment and minimize the need for
maintenance.
- 4 different gingival heights.
- 3 different grades of resistance provided by the combination
of different o-rings and housings which offer the most suitable
retention for each situation.

Note
Dual retention for optimal abutment-denture connection.
Excellent long-term performance due to wear resistant
components.

STEP 1
Screw the spherical abutment into the implant using the
torque ratchet (25 Ncm) and the driver (ref. BL-0600).

STEP 2
Rebase the overdenture according to standard procedure.

STEP 3 1
Use a laboratory burr to relieve the denture base in the
indicated areas.

29
Anchor abutment system
CE marked products by Rhein83

Smart Box Set


330SBE set includes:
1 Smart Box housing
1 Black positioning cap 330SBE

Complete 335SBC set includes: 335SBC


(complete set)
1 Smart Box housing with black positioning cap (Ref. 330SBE)
2 Stainless steel housings (Ref. 141CAE)
1 Retentive caps - violet “strong” (Ref. 140CEV)
1 Retentive caps - white “standard” (Ref. 140CET)
1 Retentive caps - pink “soft” (Ref. 140CER)
1 Retentive caps - yellow “extra-soft” (Ref. 140CEG)

D
Metal housing 2 pieces

L
L D
1.98 4.5 x2
Material: Titanium grade 5 141CAE

D
Caps 4 pieces

L
L D
1.78 3.8 x4 x4 x4 x4
Material: 140CEV - kepital 140CEV 140CET 140CER 140CEG
140CET/140CER/140CEG - pebax strong standard soft extra-soft
retention 2.7kg retention 1.8kg retention 1.2kg retention 0.6kg

D1
D2

Anchor abutment
L

L D1 D2 item#
1 134BL1
2 134BL2
3 134BL3 134BL1 134BL2 134BL3 134BL4 134BL5 134BL6
4.3 2.5
4 134BL4 h1 h2 h3 h4 h5 h6
5 134BL5
6 134BL6

Complete set includes:


1 Anchor abutment (Ref. 134BL1, 134BL2, 134BL3, 134BL4, 134BL5)
1 Stainless steel housings (Ref. 141CAE)
1 Retentive caps - violet “strong” (Ref. 140CEV)
1 Retentive caps - white “standard” (Ref. 140CET)
1 Retentive caps - pink “soft” (Ref. 140CER)
1 Retentive caps - yellow “extra-soft” (Ref. 140CEG)
1 Processing caps - black (140CEN)

Material: Titanium grade 5

30
ESTHETIC LINE implant

OT equator titanium scan abutment + titanium screw

Material: Titanium grade 5

145SAE

Laboratory accessories

D
Processing caps - black 4 pieces

L
L D
1.78 3.8 x4
Material: Rilsan 140CEN

Impression coping 2 pieces

L
L D
9 3.7 x2
Material: Acetal 144MTE

Laboratory analog with screw for CAD/CAM ø4mm

Material: Titanium grade 5

144AVC4

31
D1
D2

Laboratory analog 2 pieces


L

L D1 D2
15.6 4.3 2.5 x2
Material: Stainless steel AISI 303 144AE

Pull-off impression coping L

L D
5.5 4.6
Material: Stainless steel AISI 303 044CAIN

D
Castable cap
L
L D
2.45 3.8
Material: Crystal polystyrene 151SS

Anchor system instruments

Metal insertion/extraction tool for caps

Material: Nylon and Stainless steel


485IC

L1

D2 D1
OT-Equator square screw driver for abutment L2

L1 L2 D1 D2
774CHE
17 10.5 9 3.5 square
Material: Stainless steel 1.25 mm

L
OT-Equator square latch driver for abutment D

L D
760CE
22 2.3

Material: Stainless steel

32
ESTHETIC LINE implant

Full arch screw retained restorations

Full arch screw retained/Multi unit abutments can be used


only with splinted full arch restorations and only with a
minimum of 4 units.

Straight abutments L
C

L D C item#
1 BL-4750/1
2 BL-4750/2
2.5 5 3 BL-4750/3 BL-4750/1 BL-4750/2 BL-4750/3 BL-4750/4 BL-4750/5
4 BL-4750/4
h1 h2 h3 h4 h5
5 BL-4750/5

TIGHTENING: with torque ratchet 25 Ncm


Bridge screw torque 10 Ncm
Material: Titanium grade 5
G

L
17° angled abutments Includes internal screw BL-5052MUA C2
C1 D

L D C1 C2 G item#
1 2.5 BL-1750/1 D
2 3.5 BL-1750/2
BL-1750/1 BL-1750/2 BL-1750/3 BL-1750/4 BL-1750/5 BL-1750/6
3 4.5 BL-1750/3 h1 h2 h3 h4 h5 h6
2.5 5.5 17°
4 5.5 BL-1750/4
5 6.5 BL-1750/5
6 7.5 BL-1750/6

Over angle
TIGHTENING: with torque ratchet 25 Ncm
Bridge screw torque 10 Ncm
Material: Titanium grade 5 G

30° angled abutments Includes internal screw BL-5052MUA C2


C1 D

L D C1 C2 G item#
1 3.5 BL-3050/1 D
2 4.5 BL-3050/2
BL-3050/1 BL-3050/2 BL-3050/3 BL-3050/4 BL-3050/5 BL-3050/6
3 5.5 BL-3050/3 h1 h2 h3 h4 h5 h6
2.5 5.5 30°
4 6.5 BL-3050/4
5 7.5 BL-3050/5
6 8.5 BL-3050/6
Over angle

TIGHTENING: with torque ratchet 25 Ncm


Bridge screw torque 10 Ncm
Material: Titanium grade 5

33
D

Healing cap L

L D
5.7 5

Material: Titanium grade 5 BL-7000

D1

D1

L
Open tray transfer Includes screw BL-7012
L

L D1 D2 item#
10.5 4.2 5 BL-7011 D2
15 2.1 - BL-7012
BL-7011 BL-7012
Material: Titanium grade 5 screw

D1

Closed tray transfer L

L D1 D2
8 4.2 5 D2
Material: Titanium grade 5 BL-7010

Multi-unit analog
L

L D
14.7 5
Material: Titanium grade 5 BL-5146

34
ESTHETIC LINE implant

D1

L
Temporary titanium abutment Includes bridge screw BL-6051

L D1 D2
12 3.5 5
D2
TIGHTENING: with torque ratchet 15 Ncm BL-4526
Material: Titanium grade 5

D1

L
Castable abutment Includes bridge screw BL-6051

L D1 D2
12.45 3.3 4.6 D2

TIGHTENING: with torque ratchet 15 Ncm BL-5647

Material: Plexiglass

MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051 L

L D
10 5.2
EL-MUASCANP
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK

D
Short MUA scan Available for EXOCAD, 3SHAPE and DENTALWINGS - includes bridge screw BL-6051

L
L D
5 5.2
EL-MUASCANS
TIGHTENING: with torque ratchet 15 Ncm PEEK
Material: PEEK

35
D

L
3D MUA analog Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw DG-SCREW

L D
14 5
DG-SCREW EL-DG5146
TIGHTENING: with torque ratchet 20 Ncm included

Material: Titanium grade 5

D1

MUA bases Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw BL-6051

L D1 D2 item# D2
5 EL-DG4526S
5.8 4 EL-DG4526S EL-DG4526L
8 EL-DG4526L

TIGHTENING: with torque ratchet 15 Ncm


Material: Titanium grade 5

Bridge screw L

L D
3.5 2 BL-6051

TIGHTENING: with torque ratchet 15 Ncm


Material: Titanium grade 5

Internal prosthetic screw For angled MUA L

L D
8.6 2.2

TIGHTENING: with torque ratchet 25 Ncm BL-5052MUA

Material: Titanium grade 5

36
ESTHETIC LINE implant

Screw driver for MUA angled abutments

Material: Titanium grade 5

BL-7013

D1

L
O-ball, MUA and SSR abutments driver

L D1 D2
19.3 7.9 4.8
D2
Material: Stainless steel BL-0600

37
Screw retained restorations

STEP 1
Fabricate the stone model including analogs and gingival
mask.

STEP 2
Place and screw the castable abutments onto the
protruding multi-unit analogs.
Shorten the cylinders down to the height of the occlusal 1
plane.

STEP 3
Remove the gingiva modeling material to permit easy
access for submucosal contouring and verification of
component seating. Wax-up the bridge framework to
appropriate dimensions. The layer of wax must have
sufficient thickness to avoid the wrong coefficient of
thermal expansion and a negative effect on porcelain firing. 2

STEP 4
Prepare the wax-up for investing and casting procedures.

STEP 5
Attach the resulting framework to the models and create
final prosthesis.

STEP 6 3
Passively fit the resulting prosthesis onto the abutments.

38
ESTHETIC LINE implant

Multi-unit screw retained


abutment drill guide
Intended use
This drill guide facilitates the placement of the implants at
the correct angulations which helps assure that the final
position of the multi-unit abutment will be perpendicular to
the patient’s jaw.

Characteristics
- Durable titanium construction.
- Adjustable and foldable, allowing to be parallel to and
follow the contour of the crestal bone. 1
- Sterilizable.

STEP 1
Make a 2.0 pilot hole in order to place the guide pin.

STEP 2
After placement of the guide pin into the drilled site,
the angle and position of the guide band can be adjusted 2
to be parallel to the crestal bone.

STEP 3
The titanium band can be bent in order to follow the arch of
the crestal bone.

STEP 4
Three different angulations are indicated on the outside
of the guide, 0°, 17° and 30°. These angulations match
the angulations of the different C-TECH multi-unit screw
retained abutments. 3

STEP 5
Placement of the screw retained abutments.

EL-3017 5

39
Closed tray technique

Patient procedure
STEP 1
Remove the healing abutments.

STEP 2
Screw the abutment into the implant.

STEP 3
1
Screw each closed tray transfer onto the protruding
abutments.

STEP 4
Take the impression using an elastomeric impression
material (polyvinyl siloxan or polyether rubber).

STEP 5
Remove the closed tray transfer from the abutment.
2
STEP 6
Screw onto the abutments the healing cap screws so as
to keep the soft tissue in place until the final prosthesis is
completed.

40
ESTHETIC LINE implant

Laboratory procedure
STEP 1
Screw the closed tray transfer
onto the analog.

STEP 2
Reposition the transfer into the previously taken impression
material being sure that the transfers are properly seated.
1

STEP 3
Master model.

41
Single unit and bridge screw retained restorations

Single unit and bridge screw retained abutments are


intended for restorations which are less than a full arch.
The low profile, conical abutments provide that support
necessary for a single unit while facilitating the fitting of a
multi unit bridge.

D1

SSR Abutment GH

GH D item#
1 SSR-4710
2 SSR-4720
4.6 SSR-4710 SSR-4720 SSR-4730 SSR-4740
3 SSR-4730
4 SSR-4740
D
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5

L
SSR Comfort Cap Includes prosthetic screw SSR-50.52

L D
6.5 4.5

TIGHTENING: with torque ratchet 15 Ncm SSR-CAP

Material: PEEK

D1

L
SSR Transfer Includes prosthetic screw SSR-50.52

L D1 D2
9.3 2.89 4.6
D2
Material: Titanium grade 5 SSR-POST

D1

L
SSR Scan Cap Available for EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw SSR-50.52

L D1 D2
16 4.2 4.6
D2
TIGHTENING: with torque ratchet 15 Ncm SSR-SCAN

Material: PEEK

42
ESTHETIC LINE implant

D1

L
SSR Analog

L D
12 4.6

Material: Titanium grade 5 SSR-AN

D1

L
SSR Casting Cylinder The complete set includes prosthetic screw SSR-50.52

L D1 D2
9 3.7 4.6
D2

TIGHTENING: with torque ratchet 15 Ncm SSR-CAST

Material: Acrylic

L
SSR Bridge screw

L
6.8 SSR-50.52

TIGHTENING: with torque ratchet 15 Ncm


Material: Titanium grade 5 D1

L
O-ball, MUA and SSR abutments driver

L D1 D2
19.3 7.9 4.8
D2
Material: Titanium grade 5 BL-0600

43
Bar system D1

L
Multi-unit analog

L D
14.7 5

Material: Titanium grade 5 BL-5146

D
OT-Bar

L D
23 2 x2
Material: Polystyrene Shockproof ABS 0220BB

Clip Set includes 4 pcs

D
L D item#
x4 x4
027CRR
5 3
027CRG
026CRR 027CRG
Material: Rylsan
Soft Medium

D1

L
Castable abutment Includes bridge screw BL-6051

L D1 D2
12.45 3.3 4.6 D2

TIGHTENING: with torque ratchet 15 Ncm BL-5647

Material: Plexiglass

44
ESTHETIC LINE implant

STEP 1
Place the castable multi-unit abutments on the analogs and
tighten the bridge screws.

STEP 2
Make height adaptations according to the individual
situation.
1

STEP 3
Use a residue-free burn-out plastic to fix the bar segments
to the castable abutments.

STEP 4
The clips are fixed into the prosthesis.

45
One Time System

Titanium healing abutment L

L D C Fixture item#
5.5 2 EL-ONE TIME GS2 EL-ONETIME GS2 EL-ONETIME GS3
4.5 h2 h3
6.5 3 EL-ONE TIME GS3

TIGHTENING: with torque ratchet 10 Ncm


Material: Titanium grade 5

ONE TIME Cover screw

Material: Titanium grade 5

EL-ONETIME-CS

Titanium Base Includes prosthetic screw L L

L D
6.75 4.5
EL-ONETIME-BASE2 EL-ONETIME-BASE3
TIGHTENING: with torque ratchet 25 Ncm must be used must be used
Note: The height of the base does not change, only the height of the screw varies with EL-ONETIME GS2 with EL-ONETIME GS3
Material: Titanium grade 5

Internal prosthetic screws

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5 EL-ONETIME-S2 EL-ONETIME-S3

46
ESTHETIC LINE implant

Transfer cap L

L D
6.5 8 EL-ONETIME-CAP

Material: PEEK

Laboratory analog L

L D
12.5 4.5

Material: Titanium grade 5 EL-ONETIME-LAB

Holder

EL-ONETIME-HOLDER

47
D2

Available for EXOCAD, 3SHAPE and DENTALWINGS - L


ONE TIME Digital Analog Includes screws: DG-SCREW and BL-5052MUA

L D1 D2
11.5 3.7 4.5
D1
TIGHTENING: Bridge screw torque 20 Ncm EL-ONETIME-DG DG-SCREW BL-5052MUA
Material: Titanium grade 5 included included

NOTE: AVAILABLE FROM SEPTEMBER 2022

Scan cap for CEREC® bases L

L D
6.55 4.8
BL-6047/1 BL-6047/2
Material: Plastic for Omnicam for Bluecam

48
ESTHETIC LINE implant

Surgical protocol

STEP 1
The Gingival sleeve is placed in the implant and fastened
into the implant with the fixation screw.(25NCM)
The top of the sleeve will be approx. 1mm beneath the top
of the gingiva. 1

STEP 2
The cover screw will be placed and tightened into the
gingival sleeve finishing at a level flush with the top of the
gingival. (10NCM)

STEP 3
During the healing process, the gingival will close around
and attach itself to the gingival sleeve. 2

Prosthetic protocol

STEP 1
Once healed, the cover of the gingival sleeve is removed and
the base is placed into the gingival sleeve.
The base is fastened into the gingival sleeve with the
fixation screw (25NCM)
1
STEP 2
The reconstruction is made onto the base with no need to
remove the gingival sleeve.

49
Surgical Kit EL-SUR.KIT.01

Locator Pilot drill Paralleling pins Main drills Depth stops EL hard bone drills Counterbore
drill CT-1720E CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N EL-3138 / EL-4351
CT-2020 CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N
CT-STOP10

EL/BL implant Implant Hex Prosthetic Extractor ND implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 ratchet extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 ND-E7001 CT-2000
BL-E7001L CT-8052 ND-E7001L

Elements not included in the kit can be purchased separately.

50
ESTHETIC LINE implant

Metal Kit METALKIT03

Locator Pilot drill Depth gauges Combined Paralleling pins Main drills Depth stops EL hard bone drills Adapter Counterbore
drill CT-1720E CT-E9007 depth CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N CT-E7002 EL-3138 / EL-4351
CT-2020 CT-E9008 paralleling pins CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N CT-E7003
CT-E9010 CT-PIN1 CT-STOP10 / CT-STOP01 / CT-STOP02

EL/BL implant Implant Hex Prosthetic Extractor ND O-ball EL MUA and ND implant ND Implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 driver O-ball driver ratchet latch extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 MC-3003M BL-0600 ND-E7001 ND-E9040 CT-2000
BL-E7001L CT-8052 ND-E7001L

The Drills CT-1760E, CT-1770E, EL-1760N and EL-1770N are not included in the kit but can be purchased separately.

51
EL Prosthetic Kit PRSKIT01

EL MUA and Extractor Hex driver Latch extractor Prosthetic latch ND O-ball
O-ball driver BL-6060 CT-9025S BL-6061 BL-9019 driver
BL-0600 MC-3003M

* * * * *

Torque wrench
CT-8010

*Prosthetic parts are not included in the kit

52
ESTHETIC LINE implant

EL Planning Kit PLANKIT01

ø 4.5 straight planning abutments ø 5.5 straight planning abutments


EL-401 / EL-402 EL-502 / EL-503
EL-403 / EL-404 / EL-406 EL-504 / EL-506

15° angled planning abutments 25° angled planning abutments


EL-1501 / EL-1502 EL-2501 / EL-2502
EL-1503 / EL-1504 EL-2503 / EL-2504

53
Drill Stop Kit

STOPKIT00: Emtpy/No Contents

STOPKIT01 Contents
Stop L.6 - CT-STOP06
Stop L.7 - CT-STOP02
Stop L.8 - CT-STOP01
Stop L.9 - CT-STOP07
Stop L.10 - CT-STOP03
Stop L.11 - CT-STOP08
Stop L.12 - CT-STOP12
Stop L.13 - CT-STOP09
Stop L.14 - CT-STOP14
Stop L.15 - CT-STOP10

Bone Expander Kit


OSTKIT01

Kit Contents
Ratchet
Ratchet extender
Latch driver adapter
Locator drill
1.4 mm Drill
2.0 mm Osteotome
2.3 mm Osteotome
2.6 mm Osteotome
3.1 mm Osteotome
3.3 mm Osteotome
3.8 mm Osteotome
4.0 mm Osteotome
4.2 mm Osteotome
4.5 mm Osteotome

54
ESTHETIC LINE implant

Healing Screw Organizer

SCREWBOX00: Emtpy/No Contents

55
Instruments D2

L3

L1

Combined depth paralleling pins L2

L1 L2 L3 D1 D2
23.5 16.5 5.5 1.9 2.5 D1
Material: Titanium grade 5 CT-PIN1
1.9 mm
2.5mm

D2

L3
L1

L2
Paralleling pin

L1 L2 L3 D1 D2 x2
24.2 14.2 10.2 2 2.6 D1
CT-9003
Material: Titanium grade 5 1.6 mm
2.0mm

M4
L M3
M2
Depth gauges M1

L D M1 M2 M3 M4 item#
3 CT-E9007 D
18.5 3.8 7 9 11 13 CT-E9008
CT-E9007 CT-E9008 CT-E9010
4.6 CT-E9010
Material: Titanium grade 5

Implant ratchet drivers With retention

L item# L

10.8 BL-E7001
17.8 BL-E7001L
BL-E7001 BL-E7001L
Material: Stainless steel

56
ESTHETIC LINE implant

L1
Implant latch With retention

L
L L1 item#
16 30 BL-E9040L
11.8 25.15 BL-E9040
BL-E9040L BL-E9040

Material: Stainless steel

L1

Locator drill

L1 L2 D L2
29 15 1.6

Material: Stainless steel CT-2020

L1

Pilot drill L2

L1 L2 D
35.2 17.2 2.1
CT-1720E
Material: Stainless steel

L
Drill extender

L
25

Note: This item is intended as a drill extender and will not support more than 40Ncm. It is not intended as an implant driver extension. CT-2000

Material: Stainless steel

57
D
L

Stops L1

L1 L D item#
13.1 6. 4 CT-STOP06
12.1 7. 4 CT-STOP02
11.1 8. 4 CT-STOP01 CT-STOP06 CT-STOP02 CT-STOP01 CT-STOP07 CT-STOP03 CT-STOP08 CT-STOP12 CT-STOP09 CT-STOP14 CT-STOP10
10.1 9. 4 CT-STOP07 Stop L.6 Stop L.7 Stop L.8 Stop L.9 Stop L.10 Stop L.11 Stop L.12 Stop L.13 Stop L.14 Stop L.15
9.1 10. 4 CT-STOP03
5.2
8.1 11. 4 CT-STOP08
7.1 12. 4 CT-STOP12
6.1 13. 4 CT-STOP09
5.1 14. 4 CT-STOP14
4.1 15. 4 CT-STOP10

Intended use: Main drills diameter 2.1 mm, 3.5 mm, 4.3 mm. D
Material: Titanium grade 5

Stops XL L1

L1 L D item#
9. 4 7. 4 XLSTOP-07
8. 4 8. 4 XLSTOP-08
8. 3 XLSTOP-07 XLSTOP-08 XLSTOP-10 XLSTOP-12
6. 4 10. 4 XLSTOP-10
Tope L.07 Tope L.08 Tope L.10 Tope L.12
4. 4 12. 4 XLSTOP-12

Intended use: Main drills diameters 6 mm and 7 mm.


Material: Titanium grade 5

Main drills L

L D Fixture item#
3.3 CT-1735E D
19.2 4 CT-1743E
CT-1735E CT-1743E CT-1751E CT-1760E CT-1770E
4.8 CT-1751E
6.0 CT-1760E
17
6.5 CT-1770E

Material: Stainless steel

Counterbore L

L D Fixture item#
3.1 EL-3138 D
27.5
4.3 EL-4351
EL-3138 EL-4351
Material: Titanium grade 5

58
ESTHETIC LINE implant

Bone Taps
L
L D Fixture codice#
3.8 EL-TAP38 D
12 4.3 EL-TAP43
EL-TAP38 EL-TAP43 EL-TAP51
5.1 EL-TAP51

Material: Stainless steel

Hard bone drills L

L D Fixture codice#
item#
3.45 EL-1735N D
18.66 4.1 EL-1743N
EL-1735N EL-1743N EL-1751N EL-1760N EL-1770N
4.9 EL-1751N
5.7 EL-1760N
16.7
6.75 EL-1770N

Material: Titanium grade 5

Hex drivers
L
L item#
9.8 CT-9025XS
26 CT-9025S
CT-9025XS CT-9025S CT-9025
32 CT-9025

Material: Stainless steel

L
Prosthetic latch driver

L
26.5
Material: Stainless steel BL-9019

59
Torque wrench attachments

L item# L

12.5 CT-8051
18.5 CT-8052
CT-8051 CT-8052
Material: Stainless steel

Prosthetic extractor L

L
14.2
Material: Stainless steel BL-6060

ND O-ball driver

L L
8
Material: Stainless steel MC-3003M

L
Latch driver prosthetic extractor

L
34.25

Material: Stainless steel BL-6061

60
ESTHETIC LINE implant

Finger adapter

L D item#
5.8 12.7 CT-E7002
8.61 8 CT-E7003
CT-E7002 CT-E7003
Material: Stainless steel for ratchet for latch
drivers drivers

Torque wrench 50Ncm

Material: Stainless steel

CT-8010

61
Site preparation D2/D3

CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-E9007 EL-3138 BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill Depth Gauge Counterbore Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (outer 3.1mm) latch driver ratchet driver

Optional in case of
hard cortical bone 40Ncm 40Ncm
ø3.8

5 mm

ø1.6

CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-E9008 EL-4351 BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill Depth Gauge Counterbore Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer 3.9mm) latch driver ratchet driver
Optional in 40Ncm 40Ncm
ø4.3 case of hard
cortical bone

5 mm

ø2.15

CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-1751E CT-E9010 EL-4351 BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill 5.1mm Drill Depth Gauge Counterbore Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) (outer Ø4.6mm) latch driver ratchet driver
Optional in
case of hard 40Ncm 40Ncm
ø5.1 cortical bone

5 mm

ø3.05

*Depth: Minimum 1mm deeper than the length of implant to allow for subcrestal seating.
To avoid bone overheating, set the cutting speed between 100 and 750rpm.
Note: an additional 0.4 mm must be added to the lenght of the drill due to the lenght of the cutting tip.
62
ESTHETIC LINE implant

D1 additional steps Explanation of Drill Marking


• The drill markings do not include the point of the drill.
EL-1735N EL-TAP38 BL-E9040
3.8 mm 3.8 mm Implant latch driver
• The point of the drill is 0.4 mm long, thus the drill marking of
hard bone drill bone tap 7 mm is actually 7.4 mm from the very tip to the bottom of
Optional in case 40Ncm the first black line.
of hard bone
• The implant should be set approximately 1 mm subcrestally,
thus for a 13 mm implant, one should drill to the 14 mm.
The use of metal stop is recommended.

15.5 mm
15 mm

EL-1743N EL-TAP43 BL-E9040


4.3 mm 4.3 mm Implant latch driver
13.5 mm
hard bone drill bone tap 13 mm
Optional in case 40Ncm
of hard bone

11.5 mm
11 mm

9.5 mm
9 mm

7.5 mm
7 mm

EL-1751N EL-TAP51 BL-E9040


5.1mm 5.1 mm Implant latch driver
hard bone drill bone tap
Optional in case
of hard bone 40Ncm

0 mm

-0.4 mm

* To avoid bone overheating, set the cutting speed between 100


and 750rpm.
Note: Metal stoppers can not be mounted on ø 5.1 drills

63
Site preparation D2/D3

CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-1751E CT-1760E BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill 5.1mm Drill 6.0mm Drill Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) (outer Ø4.6mm) (outer Ø5.5mm) latch driver ratchet driver

40Ncm 40Ncm
ø6.0

5 mm

ø2.5

CT-2020 CT-1720E Parallel Pin ND-1726E CT-1735E CT-1743E CT-1751E CT-1760E CT-1770E BL-E9040 BL-E7001L
Locator Drill 2.0mm Drill CT-9003 3.1 mm drill 3.8 mm Drill 4.3 mm Drill 5.1mm Drill 6.0mm Drill 7.0mm Drill Implant Implant
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) (outer Ø4.6mm) (outer Ø5.5mm) (outer Ø6.5mm) latch driver ratchet driver

40Ncm 40Ncm
ø7.0

5 mm

ø3.4

*Depth: Minimum 1mm deeper than the length of implant to allow for subcrestal seating.
To avoid bone overheating, set the cutting speed between 100 and 750rpm.
Note: an additional 0.4 mm must be added to the lenght of the drill due to the lenght of the cutting tip.
64
ESTHETIC LINE implant

D1 additional steps

EL-1760N BL-E9040
6.0mm Implant latch driver
hard bone drill

40Ncm

EL-1770N BL-E9040
7.0mm Implant latch driver
hard bone drill
40Ncm

* To avoid bone overheating, set the cutting speed between 100


and 750rpm.
Note: Metal stoppers can not be mounted on ø 5.1 drills

65
Implant packaging

To ensure the highest level of security, our


implants are placed into a double vial inside an
airtight blister pack. Within the vials the implant
is maintained upright by a titanium ring and
supported at the implant apex by the titanium
cover screw.

Implant labeling 04/05/26


Rev.00 23/03/2020

2221 EL-

Implant dimension
3.8 L. 8 mm
EL-Dental implant D.

HIBC Health Industry


Bar Code Format
EL- Implant code/reference
Lot number 2221
+D759EL351391/$$32303121518D

Production date 04/06/21


Expiration date
04/05/26
Sterilization with
Single-use
gamma rays
The device must be use
Read the instruction sheet exclusively by the physician
ISO and CE Certification Made in Italy
by TÜV SÜD
C-TECH IMPLANT S.R.L.
Via Cesare Battisti n. 2
40123, Bologna
Tel. +39.051.66.61.817
www.c-tech-implant.com

66
ESTHETIC LINE implant

Implant vial protocol

1 2 3

4 5 6

7 8 9

67
English version

REV. 12 / 07-2022

Go to Follow us

Via Cesare Battisti n. 2 - 40123, Bologna - ITALY


Tel. +39 051 6661817 - info@c-tech-implant.com
www.c-tech-implant.com c-tech-implant.com Facebook Instagram Linkedin
NARROW
DIAMETER
implant
Implant NARROW DIAMETER

Implant characteristics pag 04 ND Metal Kit pag 19

Dental Implants pag 06 ND Prosthetic Kit pag 20

Titanium healing abutments pag 06 Bone Expander Kit pag 21

Open tray impression transfer pag 07 Drill Stop Kit pag 21

Closed tray impression transfer pag 08 Laboratory accessories pag 22

Titanium abutments pag 08 Instruments pag 22

CAD CAM components pag 10 Site preparation pag 28

Flat abutments pag 12 Explanation of drill marking pag 29

CAD CAM for flat abutments pag 13 Implant packaging pag 30

O-Ball attachment system pag 14 Implant labeling pag 30

Anchor abutment system pag 16 Implant vial protocol pag 31

Surgical Kit pag 18

All of the materials produced by C-TECH follow a validated procedure, which


includes surface treatment and packing as well, in conformity with European
and international directives EN ISO 13485, 93/42/EEC and MDR 2017/745 relative
to medical devices.

2
NARROW DIAMETER implant

Dental precision solutions


C-Tech Implant is a dynamic company with aggressive
growth, producing components and product lines primarily
for dental implantology.

International presence
With production and management based in Italy, C-Tech
Implant is active in all major world markets and is
distributed in over 33 countries.

Scientific research,
advanced technology and simplification
C-Tech Implant differentiates itself with attention to
research and the application of high technology to its
products, all while maintaining a simplicity of insertion and
ease of use.

C-Tech Implant combines the latest trends in implantology


with practical surgical and prosthetic solutions aimed at
offering the practitioner and the patient optimal results.

High quality standards


C-Tech Implant products are made to the highest standards
governing the manufacturing and management of European
medical and dental components.
Up to date audits and certifications assure that these
standards are vigilantly maintained.

Training and advice


Dental professionals are assisted by the wide knowledge
and experience of C-Tech Implant personnel and through
C-Tech courses and training sessions.
During these courses the professional is able to learn the
latest methods of implant placement and reconstruction.

Mission statement
The goal of C-Tech Implant is to provide the highest
level of quality for technologically advanced products at
reasonable prices in order to allow the dental practitioner
to find solutions for the broadest range of patients.

3
ND IMPLANT characteristics

Bevelled shoulder
- Facilitates bone growth above the shoulder Double lead thread
- Long term implant stability - Insertion rate of 1,5mm per rotation
- Biological repartition of the forces in cortical bone - Guarantees primary stability
- Increased bone to implant contact
Conical connection - Faster and even insertion while protecting bone
structure
- Structural strength stability
- Reduction of micro-movement
Thread in thread / groove in groove
- Increased bone to implant contact
Micro grooving
- Softens forces to the cortical bone during insertion
- Facilitates cortical bone maintenance
Platform switching
- Reduces bone loss
- Better representation of the biological width
Sandblasted surface
- Promotes long term esthetic stability
- Best surface for osseo integration and bone to implant
contact
Indexing hex
Aggressive apical design - Antirotational security
- Ideal for immediate implant placement
- Guarantees primary stability

Rounded apex
- Promotes the protection of the sinus floor, nerve canal
and other important anatomical structures during
insertion

Implant subcrestal seating


- Hinders exposure of the implant through bone
resorption
- Ideal for the esthetic zone
- Long term esthetic stability

Three different threading profiles


- Thread designs adapted to different bone structures
that occur along the depth of the implant
- Enhanced surface area
- Round but cutting apex design

4
NARROW DIAMETER implant

Bevelled Shoulder

Micro Grooving

Double
Lead Thread

Groove in Groove

Aggressive Apical
Design
Rounded Apex

Concave Platform Conical Indexing Hex


Esthetic Concept Switching Connection

5
Dental Implants

ND implant ø3.1

Material: titanium grade 5

ND-3009 ND-3011 ND-3013


9 mm 11 mm 13 mm

Titanium healing abutments

Healing Abutments L
C

L D C Fixture item#
0.7 2 ND-3022
1 3.8 4 ND-3024
ND-3022 ND-3024 ND-3026
1.5 6 ND-3026

TIGHTENING: with torque ratchet 10 N=Ncm


Material: titanium grade 5

Cover Screw L

L
5.8
ND-3008
TIGHTENING: with torque ratchet 10 N=Ncm 0.8mm
Material: titanium grade 5

Prosthetic screw L

L
7.7

TIGHTENING: with torque ratchet 20 N=Ncm ND-5052HX

Material: titanium grade 5

6
NARROW DIAMETER implant

Open tray impression transfer

L
Open tray transfer Includes screw ND-3041
C

L D C
ND-3040
7.5 3.8 2
Material: titanium grade 5

L
Impression post screw

L
20

ND-3041
TIGHTENING: with torque ratchet 20 N=Ncm
Material: titanium grade 5

Analog L

L D
15 3.1
Material: titanium grade 5 ND-3042

7
Closed tray impression transfer

Plastic impression cap L

L D
5 4
Material: plastic BL-4543

L
Complete set
C
L D C
11.5 3.8 2

Material: titanium grade 5 ND-3040/2 ND-5052HX BL-4543


metal screw plastic cap
transfer

Titanium abutments
D1

Titanium ø 4 straight abutments Includes screw ND-5052HX


C

L D1 D2 C Fixture item#
D2
1 ND-3025/1
8 3.8 4 2 ND-3025/2
ND-3025/1 ND-3025/2 ND-3025/3
3 ND-3025/3 h1 h2 h3

TIGHTENING: with torque ratchet 20 N=Ncm G


Material: titanium grade 5

Titanium 15°angled abutments Includes screw ND-5052HX


C

L D C Fixture G item#
1 ND-1530/1 D
6 4 2 15° ND-1530
ND-1530/1 ND-1530 ND-1530/3
3 ND-1530/3 Over flat h1 h2 h3

TIGHTENING: with torque ratchet 20 N=Ncm


Material: titanium grade 5

8
NARROW DIAMETER implant

Titanium 25°angled abutments Includes prosthetic screw ND-5052HX


C

L D C Fixture G item#
1 ND-2530/1 D
6 4 2 25° ND-2530/2
ND-2530/1 ND-2530/2 ND-2530/3
3 ND-2530/3 Over flat h1 h2 h3

TIGHTENING: with torque ratchet 20 N=Ncm D


Material: titanium grade 5

Castable abutment Includes prosthetic screw ND-5052HX


C

L D C
7.5 3.8 2 ND-5830

TIGHTENING: with torque ratchet 20 N=Ncm D1


Material: Plexiglass

Temporary peek abutment Includes prosthetic screw ND-5052HX


C

L D1 D2 C
D2
8 3.8 4 1
ND-TEMP
TIGHTENING: with torque ratchet 20 N=Ncm
Material: PEEK

Prosthetic screw L

L
7.7

TIGHTENING: with torque ratchet 20 N=Ncm ND-5052HX


Material: titanium grade 5

9
CAD CAM components
D

CEREC® base Includes prosthetic screw ND-5052HX C

L D C
4.65 4.25 2 ND-6047

TIGHTENING: with torque ratchet 20 Ncm


Material: Titanium grade 5

Scanbody for CEREC® base L

L D
6.55 3.9
BL-6047/1S BL-6047/2S
Material: Plastic for Omnicam for Bluecam

Non rotating CEC titanium bases Includes prosthetic screw ND-5052HX


C

L D C Fixture item#
1 ND-6041
5 3.8 2 ND-6042 ND-6041 ND-6042 ND-6043
3 ND-6043 h1 h2 h3

TIGHTENING: with torque ratchet 20 Ncm


D
Material: Titanium grade 5

Rotating CEC titanium bases Includes prosthetic screw ND-5052HX


C

L D C Fixture item#
1 ND-6041R
5 3.8 2 ND-6042R ND-6041R ND-6042R ND-6043R
3 ND-6043R h1 h2 h3
D
TIGHTENING: with torque ratchet 20 Ncm
Material: Titanium grade 5

Intraoral scanbody Compatible with EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw ND-5052HX

L D
9.45 3.8
ND-6040
NON ROTATING
TIGHTENING: with torque ratchet 20 Ncm
Material: PEEK

10
NARROW DIAMETER implant

L
Scan cap Compatible with EXOCAD, 3SHAPE and DENTALWINGS - Includes prosthetic screw ND-SCANSCREW

L D
12 4.8
ND-6044P ND-6044PR
NON ROTATING ROTATING
TIGHTENING: with torque ratchet 15 Ncm
D
Material: PEEK

3D Analog Compatibile with EXOCAD, 3SHAPE e DENTALWINGS - Includes prosthetic screw DG-SCREW

L D
11.5 3.2
DG-SCREW ND-DG5143
included
TIGHTENING: with torque ratchet 15 Ncm
Material: Titanium grade 5

Prosthetic screw L

L
7.7
ND-5052HX
TIGHTENING: with torque ratchet 20 Ncm
Material: titanium grade 5

Scan screw L

L D
6.1 3
ND-SCANSCREW

TIGHTENING: with torque ratchet 15 Ncm


Material: titanium grade 5

11
Flat abutments
D

L1
Flat abutments
L
L L1 D item#
8.1 2 FLAT2
9.1 3 4.5 FLAT3
FLAT2 FLAT3 FLAT4
10.1 4 FLAT4 h2 h3 h4

TIGHTENING: with torque ratchet 20 N=Ncm


Material: Titanium grade 5

Driver for Flat abutments

L item# L
9.85 FLAT-DRIVER

Material: Stainless steel FLAT-DRIVER

Flat healing screw


L1 L2

L1 L2 D
7.2 4 4.5
FLATHEALING
Material: titanium grade 5


D

Flat closed tray transfer L

L D
11.2 3.74
Material: titanium grade 5 FLATPOST


D

Flat connecting screw L

L D
6.4 2
FLATSCREW

TIGHTENING: with torque ratchet 15 N=Ncm
Material: titanium grade 5
D

Flat analog L

L D
12.5 4
Material: titanium grade 5 FLAT-AN


12
NARROW DIAMETER implant

Flat casting and titanium cylinder Includes prosthetic screw FLATSCREW L

L D item#
FLAT-CAST
11.5 3.6
FLAT-TIT
FLAT-CAST FLAT-TIT

TIGHTENING: with torque ratchet 15 N=Ncm
Material: Plexiglass and titanium grade 5

CAD CAM for flat abutments


D

L
Flat scan cap Compatible with EXOCAD, 3SHAPE e DENTALWINGS - Includes prosthetic screw FLATSCREW

L D
12 4.5 FLAT-SCAN

TIGHTENING: with torque ratchet 15 N=Ncm


Material: PEEK

Flat Base
L

L D item#
4.5 FLAT-6041S FLAT-6041S FLAT-6041L
4.5
8 FLAT-6041L

Material: titanium grade 5

Flat digital analog L

L D
11.8 4
Material: titanium grade 5 FLAT-DG

13
O-Ball attachment system

Intended use
Removable dentures retained by implants in the mandible
and maxilla.

Characteristics
- The clinical process for the o-ball attachment system is
quick, easy and functional;
- The O-ring attachment is designed to virtually eliminate
wear on the O-ball abutment and minimize the need for
maintenance;
- 3 different gingival heights;
- 3 different O-ring resistances offering optimal retention
for every individual situation.

Reliable
Dual retention for optimal abutment-denture connection.
Excellent long-term performance due to wear resistant
components.

STEP 1
Screw the spherical abutment into the implant using
butterfly key MC-3002 or ratchet driver
MC-3003S, MC-3003M or MC-3003L.

STEP 2
Rebase the overdenture according to the standard
procedure.

14
NARROW DIAMETER implant

Butterfly driver

D L
L
8.5 7

Material: Stainless steel MC-3002

O-Ball abutments C

L D C item#
1 ND-5641
3.77 3.8 2 ND-5642
3 ND-5643 ND-5641 ND-5642 ND-5643

TIGHTENING: with torque ratchet 20Ncm


Complete set includes:
O-Ring (Ref. MC-3005) 1 piece
Metal Housing (Ref. MCH-2)
O-Ball Abutment (Ref. ND-5641, ND-5642, ND-5643)
Material: Titanium grade 5

D D

Soft retention caps L

L D o-ring D
3.5 4.7 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna
soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4

D D

Medium & hard retention caps L

L D item# o-ring D
x5 x10 x25
3.2 4.2 MCH-2 3.8
2.9 4 MCH-3 MCH-2 MCH-3 MC-3005 MC-3005/10 MC-3005/25
medium hard O-RING O-RING O-RING
Material: Titanium grade 5 Material: FDA Buna 5 pieces 10 pieces 25 pieces

Available in single packages: MCH-2, MCH-3


Available in packages of 4 caps: MCH-2/4, MCH-3/4

15
Anchor abutment system
CE marked products by Rhein83

Smart Box Set


330SBE set includes:
1 Smart Box housing
1 Black positioning cap 330SBE

Complete 335SBC set includes: 335SBC


(complete set)
1 Smart Box housing with black positioning cap (Ref. 330SBE)
2 Stainless steel housings (Ref. 141CAE)
1 Retentive caps - violet “strong” (Ref. 140CEV)
1 Retentive caps - white “standard” (Ref. 140CET)
1 Retentive caps - pink “soft” (Ref. 140CER)
1 Retentive caps - yellow “extra-soft” (Ref. 140CEG)

D
Metal housing 2 pieces

L
L D
1.98 4.5 x2

141CAE

D
Plastic caps 4 pieces

L
L D
1.78 3.8 x4 x4 x4 x4
Material: 140CEV - kepital 140CEV 140CET 140CER 140CEG
140CET/140CER/140CEG - pebax
strong standard soft extra-soft
retention 2.7kg retention 1.8kg retention 1.2kg retention 0.6kg

OT equator titanium scan abutment + titanium screw

145SAE

16
NARROW DIAMETER implant

Laboratory analog with screw for CAD/CAM ø4mm

144AVC4

D1
D2

Anchor abutment L

L D1 D2 item#
2.4 130ND31
3.4 130ND32
4.4 4.3 2.5 130ND33 130ND31 130ND32 130ND33 130ND34 130ND35
5.4 130ND34 h1 h2 h3 h4 h5
6.4 130ND35

Complete set includes:


1 Anchor abutment (Ref. 130ND31, 130ND32, 130ND33, 130ND34, 130ND35)
1 Stainless steel housings (Ref.141CAE)
1 Retentive caps - violet “strong” (Ref. 140CEV)
1 Retentive caps - white “standard” (Ref. 140CET)
1 Retentive caps - pink “soft” (Ref. 140CER)
1 Retentive caps - yellow “extra-soft” (Ref. 140CEG)

Material: Titanium grade 5

17
ND Surgical Kit EL-SUR.KIT.01

Locator Pilot drill Paralleling pins Main drills Depth stops EL hard bone drills Counterbore
drill CT-1720E CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N EL-3138 / EL-4351
CT-2020 CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N
CT-STOP10

EL/BL implant Implant Hex Prosthetic Extractor ND implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 ratchet extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 ND-E7001 CT-2000
BL-E7001L CT-8052 ND-E7001L

Elements not included in the kit can be purchased separately.

18
NARROW DIAMETER implant

ND Metal Kit METALKIT03

Locator Pilot drill Depth gauges Combined Paralleling pins Main drills Depth stops EL hard bone drills Adapter Counterbore
drill CT-1720E CT-E9007 depth CT-9003 ND-1726 / CT-1735E CT-STOP07 / CT-STOP03 / CT-STOP08 ND-1731N / EL-1735N CT-E7002 EL-3138 / EL-4351
CT-2020 CT-E9008 paralleling pins CT-1743E / CT-1751E CT-STOP12 / CT-STOP09 / CT-STOP14 EL-1743N / EL-1751N CT-E7003
CT-E9010 CT-PIN1 CT-STOP10 / CT-STOP01 / CT-STOP02

EL/BL implant Implant Hex Prosthetic Extractor ND O-ball EL MUA and ND implant ND Implant Drill Torque wrench
ratchet latch driver ratchet BL-6060 driver O-ball driver ratchet latch extender CT-8010
BL-E7001 BL-E9040 CT-9025S CT-8051 MC-3003M BL-0600 ND-E7001 ND-E9040 CT-2000
BL-E7001L CT-8052 ND-E7001L

The Drills CT-1760E, CT-1770E, EL-1760N and EL-1770N are not included in the kit but can be purchased separately.

19
ND Prosthetic Kit PRSKIT01

EL MUA and Extractor Hex driver Latch extractor Prosthetic latch ND O-ball driver
O-ball driver BL-6060 CT-9025S BL-6061 BL-9019 MC-3003M
BL-0600

* * * * *

Torque wrench
CT-8010

*Prosthetic parts are not included in the kit

20
NARROW DIAMETER implant

Bone Expander Kit OSTKIT01

Kit Contents
Ratchet
Ratchet extender
Latch driver adapter
Locator drill
1.4 mm Drill
2.0 mm Osteotome
2.3 mm Osteotome
2.6 mm Osteotome
3.1 mm Osteotome
3.3 mm Osteotome
3.8 mm Osteotome
4.0 mm Osteotome
4.2 mm Osteotome
4.5 mm Osteotome

Drill Stop Kit

STOPKIT00: Emtpy/No Contents

STOPKIT01 Contents
Stop L.6 - CT-STOP06
Stop L.7 - CT-STOP02
Stop L.8 - CT-STOP01
Stop L.9 - CT-STOP07
Stop L.10 - CT-STOP03
Stop L.11 - CT-STOP08
Stop L.12 - CT-STOP12
Stop L.13 - CT-STOP09
Stop L.14 - CT-STOP14
Stop L.15 - CT-STOP10

21
Laboratory accessories

O-ball temporary and transfer caps L

D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
MC-3013 MC-3014 MC-3014S
4.5 6.4 MC-3014S Temporary O-ball Square head
cap transfer cap transfer cap
Material: POM

Collared analog L

D L
2.6 15.8

Material: Titanium grade 5


MC-3007

D2

Instruments L3

L1

Combined depth paralleling pins L2

L1 L2 L3 D1 D2
23.5 16.5 5.5 1.9 2.5 D1

Material: Titanium grade 5 CT-PIN1


1.9 mm
2.5mm
D1

L1

Paralleling pin
L2 L3
L1 L2 L3 D1 D2
24.2 14.2 10.2 2 2.6
D2
Material: Titanium grade 5
CT-9003
1.6 mm
2.0mm

22
NARROW DIAMETER implant

L
Drill Extender

L
25

Note: This item is intended as a drill extender and will not support more than 40Ncm. It is not intended as implant driver extension. CT-2000
Material: Stainless steel

Implant ratchet driver

L item# L
9.85 ND-E7001
17.75 ND-E7001L
ND-E7001 ND-E7001L
Material: Stainless steel

Implant latch driver

L L

11.8
Material: Stainless steel ND-E9040

L1

Locator drill

L1 L2 D L2
29 15 1.6
Material: Stainless steel CT-2020

23
L1

Initial drill
L2

L1 L2 D
35.2 17.2 2.1
D
Material: Stainless steel CT-1720E

L1

Main drill L2

L1 L2 D
36.7 15.9 2.6
D
Material: Stainless steel ND-1726E

L1

Hard bone drills

L2
L1 L2 D
34 15.5 3 D
Material: Stainless steel ND-1731N

L1

L3
Counterbore L2

L1 L2 D2 L3 D3 D2
23.9 4.8 3.1 4.5 3.5 D3
Material: Stainless steel EL-3138

24
NARROW DIAMETER implant

Bone Tap
L
L D
10 3.1 D
Material: Stainless steel EL-TAP31

Stops

L D item#
9 CT-STOP07
11 5.2 CT-STOP08
CT-STOP07 CT-STOP08 CT-STOP09
13 CT-STOP09 Stop L.9 Stop L.11 Stop L.13
Material: Stainless steel

Prosthetic latch driver L

L
26.5
Material: Stainless steel BL-9019

25
Torque wrench attachments

L item# L

12.5 CT-8051
18.5 CT-8052
CT-8051 CT-8052
Material: Stainless steel

Hex drivers

L item# L

9.8 CT-9025XS
12.5 CT-9025S
CT-9025XS CT-9025S CT-9025
18.5 CT-9025

Material: Stainless steel

Butterfly driver

D L
L
8.5 7

Material: Stainless steel MC-3002

O-ball driver

L L
8
Material: Stainless steel MC-3003M

26
NARROW DIAMETER implant

Finger adapter L

L D item#
5.8 12.7 CT-E7002
8.61 8 CT-E7003
CT-E7002 CT-E7003
Material: Stainless steel for ratchet for latch
drivers drivers

Torque Wrench 50Ncm

Material: Stainless steel

CT-8010

27
Site preparation D1/D2

CT-2020 CT-1720E CT-9003 ND-1726E EL-3138 ND-E9040 ND-E7001L


Locator Drill 2.0mm Drill Parallel Pin 3.1mm drill Counterbore Implant latch driver Implant
(Outer Ø 2.0mm) (Outer Ø2.6mm) ratchet driver
Optional in case of hard 40Ncm 40Ncm
ø3.1 cortical bone

5 mm

Site preparation D3

EL-1731N EL-TAP31 ND-E9040


3.1 mm 3.1 mm Implant latch driver
hard bone drill bone tap

Optional in case 40Ncm


ø3.1 of hard bone

*Depth: Minimum 1mm deeper than length of implant is to allow for subcrestal seating.
To avoid bone overheating, set the cutting speed between 100 and 750rpm.
Note: an additional 0.4 mm must be added to the lenght of the drill due to the leght of the angled cutting tip.

28
NARROW DIAMETER implant

Explanation of Drill Marking


• The drill markings do not include the point of the drill.
• The point of the drill is 0.4 mm long, thus the drill marking of
7 mm is actually 7.4 mm from the very tip to the bottom of
the first black line.
• The implant should be set approximately 1 mm subcrestally,
thus for a 13 mm implant, one should drill to the 14 mm.
The use of metal stop is recommended.

15.5 mm
15 mm

13.5 mm
13 mm

11.5 mm
11 mm

9.5 mm
9 mm

7.5 mm
7 mm

0 mm

-0.4 mm

29
Implant packaging

To ensure the highest level of security, our


implants are placed into a double vial inside an
airtight blister pack. Within the vials the implant
is maintained upright by a titanium ring and
supported at the implant apex by the titanium
cover screw.

Implant labeling 04/05/26


Rev.00 23/03/2020

2221 ND-

Implant dimension
3.1 L. 9 mm
ND-Dental implant D.

HIBC Health Industry


Bar Code Format
ND- Implant code/reference
Lot number 2221
+D759EL351391/$$32303121518D

Production date 04/06/21


Expiration date
04/05/26
Sterilization with
Single-use
gamma rays
The device must be use
Read the instruction sheet exclusively by the physician
ISO and CE Certification Made in Italy
by TÜV SÜD
C-TECH IMPLANT S.R.L.
Via Cesare Battisti n. 2
40123, Bologna
Tel. +39.051.66.61.817
www.c-tech-implant.com

30
NARROW DIAMETER implant

Implant vial protocol

1 2 3

4 5 6

7 8 9

31
English version

REV. 08 / 04-2022

Go to Follow us

Via Cesare Battisti n. 2 - 40123, Bologna - ITALY


Tel. +39 051 6661817 - info@c-tech-implant.com
www.c-tech-implant.com c-tech-implant.com Facebook Instagram Linkedin
SMALL
DIAMETER
Implant
SMALL DIAMETER Implant

Implant characteristics page 04

Dental Implants page 06

Prosthetic components page 10

MONOBLOCK Implant
Implant characteristics page 12

Dental Implants page 14

Prosthetic components page 16

SD/MB Surgical section


Instruments page 18 Prosthetic Protocol page 25

Surgical Kit page 21 Site preparation page 26

Surgical Protocol page 24 Site preparation page 28

All of the materials produced by C-TECH follow a validated procedure, which includes
surface treatment and packing as well, in conformity with European and international
directives EN ISO 13485, 93/42/EEC and MDR 2017/745 relative to medical devices.

2
SMALL DIAMETER Implant

Dental precision solutions


C-Tech Implant is a dynamic company with aggressive
growth, producing components and product lines primarily
for dental implantology.

International presence
With production and management based in Italy, C-Tech
Implant is active in all major world markets and is
distributed in over 33 countries.

Scientific research, advanced technology,


simplification
C-Tech Implant differentiates itself with attention to
research and the application of high technology to its
products, all while maintaining a simplicity of insertion and
ease of use.

C-Tech Implant incorporates the latest trends in


implantology but provides very practical surgical and
prosthetic solutions aimed at offering the practitioner and
the patient optimal results.

High quality standards


C-Tech Implant products are made to the highest standards
governing the manufacturing and management of European
medical and dental components.
Up to date audits and certifications assure that these
standards are vigilantly maintained.

Training & advice


Dental professionals are assisted by the rich knowledge
and experience of C-Tech Implant personnel and through
C-Tech courses and training sessions.
During these courses the professional is able to learn the
latest methods of implant placement and reconstruction.

Mission statement
The goal of C-Tech Implant is to provide the highest
level of quality for technologically advanced products at
reasonable prices in order to allow the dental practitioner
to find solutions for the broadest range of patients.

3
SMALL DIAMETER Implant

Prosthetic choice Collared and non-collared models


Choice between square or o-ball head depending on fixed or C-tech provides SD models with and without gingival
removable applications. collars, allowing the practitioner to better address cases
with differing gingival thicknesses.
Micro grooving
The lower aspect of the implant collar is endowed with
micro grooves to help maintain cortical bone.

Fine threading
The fine thread SD implants are designed to facilitate the
placement in hard bone.

SEM 1000x Passivated surface


The implant surface is sandblasted.
This surface treatment accelerates the
osteointegration process by providing
a greater and more uniform area of
contact between bone and implant while
favoring an immediate implant load.

Implant body
The anatomically shaped implants are produced from
medical grade 5 titanium.

Smooth collar
The top aspect of every collared implant is smooth so as to
better accommodate soft tissue.

Aggressive threading
The aggressive thread for SD Implants are designed for the
added compression and surface area required in soft bone
placement.

4
SMALL DIAMETER Implant

Square Head

O-Ball Head
With collar

With Smooth
Gingival
Collar
Without Collar
Micro Grooving

Fine
Threading

Aggressive
Passivated Threading
Surface

5
Dental Implants

SD Implant ø1.8 fine thread implants C

L
D L T C A item#
16.3 10 CAB-10 T
17.8 11.5 CAB-115
1.8 19.3 13 2.5 3.8 CAB-13
21.3 15 CAB-15
24.3 18 CAB-18 D

CAB-10 CAB-115 CAB-13 CAB-15 CAB-18


10 mm 11.5 mm 13 mm 15 mm 18 mm

A
SD Implant ø1.8 fine thread implants

D L T A item# L
13.9 10 NAB-10 T
1.8 16.9 13 3.9 NAB-13
18.9 15 NAB-15

NAB-10 NAB-13 NAB-15


10 mm 13 mm 15 mm

SD Implant ø1.8 fine thread implants C

L
D L T C A item#
16.3 10 SAB-10
T
1.8 19.3 13 2.5 3.8 SAB-13
21.3 15 SAB-15

SAB-10 SAB-13 SAB-15


10 mm 13 mm 15 mm

6
SMALL DIAMETER Implant

SD Implant ø2.1 fine thread implants C

L
D L T C A item#
16.3 10 IAB-10 T
17.8 11.5 IAB-115
2.1 19.3 13 2.5 3.8 IAB-13
21.3 15 IAB-15
24.3 18 IAB-18 D

IAB-10 IAB-115 IAB-13 IAB-15 IAB-18


10 mm 11.5 mm 13 mm 15 mm 18 mm

A
SD Implant ø2.1 fine thread implants

D L T A item# L
13.9 10 NIAB-10 T
2.1 16.9 13 3.9 NIAB-13
18.9 15 NIAB-15

NIAB-10 NIAB-13 NIAB-15


10 mm 13 mm 15 mm

SD Implant ø2.1 fine thread implants C

L
D L T C A item#
16.3 10 SIAB-10
T
2.1 19.3 13 2.5 3.8 SIAB-13
21.3 15 SIAB-15

SIAB-10 SIAB-13 SIAB-15


10 mm 13 mm 15 mm

7
Dental Implant

SD Implant ø2.5 fine thread implants C

L
D L T C A item#
16.3 10 MC/25/10
T
2.5 19.3 13 2.5 3.8 MC/25/13
21.3 15 MC/25/15

MC/25/10 MC/25/13 MC/25/15


10 mm 13 mm 15 mm

SD Implant ø2.5 fine thread implants C

L
D L T C A item#
16.3 10 MCA/25/10 T
2.5 19.3 13 2.5 3.8 MCA/25/13
21.3 15 MCA/25/15

MCA/25/10 MCA/25/13 MCA/25/15


10 mm 13 mm 15 mm

8
SMALL DIAMETER Implant

SD Implant ø2.4 aggressive thread implants C

L
D L T C A item#
16.3 10 MAB-10
T
19.3 13 MAB-13
2.4 2.5 3.8
21.3 15 MAB-15
24.3 18 MAB-18
D

MAB-10 MAB-13 MAB-15 MAB-18


10 mm 13 mm 15 mm 18 mm

A
SD Implant ø2.4 aggressive thread implants

D L T A item# L
13.9 10 NMAB-10
T
2.4 16.9 13 3.9 NMAB-13
18.9 15 NMAB-15

NMAB-10 NMAB-13 NMAB-15


10 mm 13 mm 15 mm

SD Implant ø2.4 aggressive thread implants C

L
D L T C A item#
16.3 10 SMAB-10
T
2.4 19.3 13 2.5 3.8 SMAB-13
21.3 15 SMAB-15

SMAB-10 SMAB-13 SMAB-15


10 mm 13 mm 15 mm

9
Prosthetic components
D D

Soft retention caps L

D L O-Ring D
4.7 3.5 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4

D D

Medium retention caps L

D L O-Ring D
x5 x10 x25
4.3 3.1 3.8
MCH-2 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna medium O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-2
Available in packages of 4 caps: MCH-2/4
D D

Hard retention caps L

D L O-Ring D
x5 x10 x25
4 3.1 3.8
MCH-3 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna hard O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-3
Available in packages of 4 caps: MCH-3/4
D

Straight abutment Only for O-ball heads implants L

D L
4.3 9.4

Material: Titanium grade 5 MC-3010

SD 15° angled abutment L

D L
4.6 9.3

Material: Titanium grade 5 MC-3011

O-ball temporary and transfer caps For O-ball and square head implants L

D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
MC-3013 MC-3014 MC-3014S
4.5 6.4 MC-3014S Temporary Cap O-ball Transfer Square Head
for O-ball and cap Transfer cap
Material: PEEK
Square Head

10
SMALL DIAMETER Implant

Castable cap for square head and O-ball L

D L
4 6

Material: Plexiglass MC-3006

D
PVC protection

D L L

3.5 4
x5 x10 x25

Material: PVC MC-3008 MC-3008/10 MC-3008/25


5 pieces 10 pieces 25 pieces

L
Collared analog

D L
2.6 15.8

Material: Titanium grade 5 MC-3007

L
Non collared analog

D L
2.0 15.8

Material: Titanium grade 5 MC-3012

L
Collared square head analog

D L
2.6 15.8

Material: Titanium grade 5 MCA-1007

11
MONOBLOCK Implant

The C-Tech MB, Mono Block Implant, provides 2 different System Compatiblity
prosthetic options as well as 2 different main body designs Choice of tapered and O-ball head prosthetics.
to meet the differing requirements of bone and soft tissue O-ball head is compatible with SD, GL, BL and EL O-ball
encountered in the maxilla and the mandible. attachments

Prosthetic Options Augmented Gingival Collar


Choice between square or O-ball head depending on fixed or MAX-OB/MAX-TAP smooth collar platform switching fits
removable applications. the thicker maxillary gingival tissue

Support for Fixed Recontructions Maxilla Type Bone Micro Grooving


A tapered head with a 4,8mm height above the 3,1mm MAX-OB/MAX-TAP micro grooving accommodates the
platform offers and optimal base and structure for the fixed thinner cortical bone that is encountered in the maxilla.
reconstruction.
Aggressive Main Body Threading
Gingival Collar MAX-OB/MAX-TAP main body threading, agressive reverse
MAN-OB/MAN-TAP smooth collar provides the platform buttress threads deliver the surface area and stability
switching height to accommodate the average mandibular required by softer maxillary bone
gingival tissue.
Maxilla Type Apex
Mandibular Cortical Maintenance Rounded tip is ideal for the maxilla so as to prevent the
Augmented MAN-OB/MAN-TAP micro grooving for the possible perforation of the sinus.
increased cortical height of the mandibular bone.

Low Profile Threading


Low profile threading offers surface area yet with the
reduced resistance necessary for placement in the D1/D2
bone that can be encountered in the mandible.

Surface Topography
Blasted main body surface.

Mandibular Apex
Sharp apex to facilitate advancement in D1/D2 bone.

12
MONOBLOCK Implant

Prosthetic Options: Prosthetic


O-Ball for removable Choice: Tapered
prosthesis Abutment for fixed
recontructions

Gingival Choice:
Maxilla Type
Gingival Choice:
Gingival Collar
Mandibular Type
Cortical Choice: Gingival Collar
Maxilla Type
Cortical Choice:
Micro Grooving
Mandibular Type
Micro Grooving

Choice Of Main
Choice Of Main Body Threading:
Body Threading: Fine Threading
Agressive for Hard Bone
Threading for
Soft Bone

Rounded Apex Pointy Apex

13
Dental Implants

A
MANOB C

L
D L T C A item#
14.3 9 MANOB-09 T
16.3 11 MANOB-11
3 1.5 3.8
18.3 13 MANOB-13
20.3 15 MANOB-15

MANOB-09 MANOB-11 MANOB-13 MANOB-15


9 mm 11 mm 13 mm 15 mm

MAXOB C

L
D L T C A item#
15.3 9 MAXOB-09 T
17.3 11 MAXOB-11
3 2.5 3.8
19.3 13 MAXOB-13
21.3 15 MAXOB-15

MAXOB-09 MAXOB-11 MAXOB-13 MAXOB-15


9 mm 11 mm 13 mm 15 mm

MANTAP C

L
D L T C A item#
15.3 9 MANTAP-09 T
17.3 11 MANTAP-11
3 1.5 4.8
19.3 13 MANTAP-13
21.3 15 MANTAP-15

MANTAP-09 MANTAP-11 MANTAP-13 MANTAP-15


9 mm 11 mm 13 mm 15 mm

14
MONOBLOCK Implant

MAXTAP C

L
D L T C A item#
16.3 9 MAXTAP-09 T
18.3 11 MAXTAP-11
3 2.5 4.8
20.3 13 MAXTAP-13
22.3 15 MAXTAP-15

MAXTAP-09 MAXTAP-11 MAXTAP-13 MAXTAP-15


9 mm 11 mm 13 mm 15 mm

15
Prosthetic components
D D

Soft retention caps L

D L O-Ring D
4.7 3.5 4.4
x5 x10 x25
MCH-1 MC-3005B MC-3005B/10 MC-3005B/25
Material: Titanium grade 5 Material: FDA Buna soft O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-1
Available in packages of 4 caps: MCH-1/4

D D

Medium retention caps L

D L O-Ring D
x5 x10 x25
4.3 3.1 3.8
MCH-2 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna medium O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-2
Available in packages of 4 caps: MCH-2/4

D D

Hard retention caps L

D L O-Ring D
x5 x10 x25
4 3.1 3.8
MCH-3 MC-3005 MC-3005/10 MC-3005/25
Material: Titanium grade 5 Material: FDA Buna hard O-RING O-RING O-RING
5 pieces 10 pieces 25 pieces
Available in single packages: MCH-3
Available in packages of 4 caps: MCH-3/4
D

Straight abutment Only for O-ball heads implants L

D L
4.3 9.4

Material: Titanium grade 5 MC-3010

SD 15° angled abutment L

D L
4.6 9.3

Material: Titanium grade 5 MC-3011


D

O-ball temporary and transfer caps For O-ball and square head implants L

D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
MC-3013 MC-3014 MC-3014S
4.5 6.4 MC-3014S Temporary Cap O-ball Transfer Square Head
for O-ball and cap Transfer cap
Material: PEEK
Square Head

16
MONOBLOCK Implant

Castable cap for square head and O-ball L

D L
4 6

Material: Plexiglass MC-3006

Tapered head caps Only for tapered head implants L

D L item#
4 6.9 MB-3013
MB-3014
2.1 6.5 MB-3013 MB-3014 MB-3006
MB-3006 Tapered Tapered Castable
impression cap temp cap cap
Material: MB-3013 - PEEK
MB-3014 - PEEK
MB-3006 - CPMMA

D
PVC protection

D L L

3.5 4
x5 x10 x25

Material: PVC MC-3008 MC-3008/10 MC-3008/25


5 pieces 10 pieces 25 pieces

L
Collared O-ball analog

D L
2.6 15.8

Material: Titanium grade 5 MC-3007

L
Tapered analog

D L
3.1 17.85

Material: Titanium grade 5 MB-ANALOG

17
Instruments L1

L2
SD Drills

D L1 L2 item#
1.1 MC-3001/11 D
14.3
1.3 MC-3001/13
33.3 MC-3001/11 MC-3001/13 MC-3001 MC-3001/20
1.5 MC-3001 single use
17.5
2.0 MC-3001/20

Material: Stainless steel D

SB/MB Butterfly driver

D L
L
8.5 7

Material: Stainless steel MC-3002

SD/MB Adapters

L item#
4 MC-3003S L
8 MC-3003M
MC-3003S MC-3003M MC-3003L
12 MC-3003L Short Medium Long
Material: Stainless steel

L
SD/MB Latch implant driver

D L
3.2 22 D
Material: Stainless steel MC-3020

SD/MB Finger adapter

D L
12 8.6

Material: Stainless steel CT-E7002


for ratchet drivers

18
MINI Implant

L1
L1

L2
L2
SD/MB Marking and pilot drills

L1 L2 D item#
D D
29 15 2.1 CT-2020
35.2 17.2 2.1 CT-1720E
CT-2020 CT-1720E

Material: Stainless steel

L1

L3
Counterbore L2

L1 L2 D2 L3 D3 D2
23.9 4.8 3.1 4.5 3.5 D3
Material: Stainless steel EL-3138

L1

MB Main drill L2

L1 L2 D
36.7 17.2 2.6
D
Material: Stainless steel ND-1726E

L
MB Drill Extender

L
25
Material: Stainless steel CT-2000

MB Tissue punch

D L
3 2.8 D
Material: Stainless steel TCP-3MM

19
Instrumentation

SD/MB Torque wrench up to 50Ncm

CT-8010

SD/MB O-ring tool

Material: Stainless steel

MC-3018

20
MINI Implant

SD/MB Kit SURKIT05

Torque wrench Adapters Butterfly driver Tissue punch


CT-8010 MC-3003M - MC-3003L MC-3002 TCP-3MM

Locator drill Drill extender Initial drill Drills Main drill Counterbore
CT-2020 CT-2000 CT-1720E MC-3001/11 - MC-3001/13 ND-1726E EL-3138
MC-3001

21
SD Kit MC-00075SC

Torque wrench Butterfly driver


CT-8010 MC-3002

Drills* Adapters
MC-3001/11 - MC-3001/13 MC-3003S
MC-3001 - MC-3001/20 MC-3003L

* Each surgical kit is equipped with 2 drills; customers can chose drills between ø 1.1 , 1.3, 1.5, 2.0. Customers should communicate the choice of the drills
at the moment of the order.

22
MINI Implant

ND/MB Kit SURKIT06

Torque wrench ND implant Adapters Butterfly driver Prosthetic Hex Tissue punch
CT-8010 ratchet MC-3003M - MC-3003L MC-3002 ratchet driver TCP-3MM
ND-E7001 CT-8051 CT-9025S
ND-E7001L

Locator drill Drill extender Initial drill Depth stops Main drill Counterbore
CT-2020 CT-2000 CT-1720E CT-STOP07 - CT-STOP08 ND-1726E EL-3138
CT-STOP09

23
Surgical Protocol

Case planning
Following evaluation of the patient and the corresponding
panoramic radiographs, the type and number of implants and
planned placement sites are established. There should be a
minimum of 4 implants for mandibular cases and a minimum of 6
for maxilla cases. The implant planning transparency is used to
establish the implant length. A minimum of 5mm between each
implant needs to be maintained to allow space for the housings.
In mandibular cases the implants should be placed starting with a 1
minimum of 5mm anterior of the mental foramen. Following implant
site planning the sites are transferred to the gingiva and marked
with sterile marker or bleeding points.

Pilot site drilling and initial insertion


The drill is placed over the sites and lightly pumped up and down
till the cortical plate is perforated. The drill should provide sterile
irrigation. Unless the crestal bone is sharp or defective there will
be no need to raise flap or incision. In the case of average hardness 2
of the bone, then the drill depth should be approximately 1/3 the
length of the implant. In the case of hard bone then the depth
should be extended to ¾ of the length of the implant.
The implant is removed from the sterile vial and the tip of the
implant is placed into the drilled site, using the implant mount
cap as initial driver. The implant is driven into the bone exerting
downward pressure and clockwise motions. Once the bone has
been engaged the resistance will become too great to proceed
further, it is now time to disengage the cap from the implant and
proceed to the next instrument.
3

Continuing the insertion with the butterfly driver


Following the initial insertion one will use the butterfly driver,
which allows for applying more torque. It should be possible to
seat the implant completely with this instrument but should the
implant not be completely seated and further advancement is not
possible due to resistance, one will then require the ratchet or
torque ratchet for final seating.
4

Final implant seating


Final seating is accomplished through use of the torque ratchet.
The torque ratchet should be set to 35 Ncm. The ratchet adapter is
inserted into the opening at the end of the ratchet with the female
aspect of the adapter protruding. The adapter is then fitted over
the top of the implant, engaging the square part beneath the O-ball.
A finger should be placed over the end of the ratchet in order to
stabilize the insertion and prevent lever action on the end of the
5
implant. The ratchet is moved in quarter turn increments, pausing
in between each turn, thus allowing the bone to expand.
The implant is considered primarily stable once 35 Ncm has been
achieved. The implant is completely seated once the O-ball and
the square part beneath are the only parts protruding from the
gingiva. If primary stability has been achieved prior to achieving
final seating, then the torque setting should be raised to 50 Ncm,
the point at which a fracture can occur. Should the resistance
be too much to achieve final seating, then the implant should be
slowly backed out and the pilot drill should be used to deepen the
osteotome site.

24
MINI Implant

Prosthetic Protocol

Following proper prosthetic protocol


is essential to case success
The base of the denture is relieved in order to freely accommodate
the heads of the implants and the housings seated on the o-balls.
The denture should be relieved until the housings no longer come
into contact with the ceiling of the denture base.
The denture should be cleaned thoroughly of all acrylic powder
residue. 1
Take the PVC tubing and, using a scalpel or scissors, cut off 1.5mm
lengths corresponding to the quantity of set implants.
Slip the cut lengths of tubing around the necks of the implant
heads and into the gingiva but below the implant O-ball.
Fit the housings over all O-ball heads, the tubing should not
obstruct the full seating of the housings over the O-balls.
Using cold curing acrylic, apply small amounts to the tops of the
housings and fill the hollowed trough of the denture base with the
acrylic.
Set the denture over the housings in the patient’s mouth.
Have the patient bite down on the denture in a normal occlusion 2
with normal pressure.
The acrylic will require approx 8 minutes to set, after which the
denture is removed and excess acrylic is trimmed and polished
away.

4 5

6 7

8 9

25
Site preparation

Ø1.8 - Ø 2.1 CAB/NAB/SAB/IAB/NIAB/SIAB

3,8 mm 3,8 mm

1/3 Length of implant

Insertion Torque:

Insertion Torque:
100 - 750 rpm
2,5 mm

35 - 45 ncm

35 - 45 ncm
2,5 mm

L. 10 mm L. 10 mm
L. 11,5 mm L. 11,5 mm
L. 13 mm L. 13 mm
L. 15 mm L. 15 mm

ø1.8 ø2.1 MC-3001/11 MC-3002 MC-3003S


ø 1.1 mm Drill Butterfly Driver MC-3003M
MC-3003L
Ratchet Adapter

Ø2.5 - Ø 2.4 MC-25/MCA-25/MAB/NMAB/SMAB

3,8 mm 3,8 mm
1/3 Length of implant

Insertion Torque:

Insertion Torque:
100 - 750 rpm

2,5 mm
35 - 45 ncm

35 - 45 ncm

2,5 mm

L. 10 mm L. 10 mm
L. 13 mm L. 13 mm
L. 15 mm L. 15 mm

ø2.5 ø2.4 MC-3001/11 MC-3002 MC-3003S


ø 1.1 mm Drill Butterfly Driver MC-3003M
MC-3003L
Ratchet Adapter

26
SMALL DIAMETER Implant

D1 ADDITIONAL STEPS
Full Length of implant

Insertion Torque:

Insertion Torque:
100 - 750 rpm

35 - 45 ncm

35 - 45 ncm

MC-3001 MC-3002 MC-3003S


ø 1.5 mm Drill Butterfly Driver MC-3003M
MC-3003L
Ratchet Adapter

D1/D2 ADDITIONAL STEPS


Full Length of implant

Insertion Torque:

Insertion Torque:
100 - 750 rpm

35 - 45 ncm

35 - 45 ncm

MC-3001 MC-3002 MC-3003S


ø 1.5 mm Drill Butterfly Driver MC-3003M
MC-3003L
Ratchet Adapter

27
Site preparation

MAN - TAPER / MAN - O-BALL FOR DENSITY D1/D2

2.3mm
4.8mm
3.8mm

2/3 Length of implant


Full Length of implant

Insertion Torque:
800 - 1000 rpm
ø3.2 ø3.0

100 - 750 rpm

100 - 750 rpm

35 - 45 ncm
1.5mm 1.5mm
ø3.0 ø3.0

9mm 9mm 4 mm
11mm 11mm
13mm 13mm
15mm 15mm

TCP - 3mm CT-2020 CT-1720E ND-1726E MC-3003S


ø3.0 ø3.0 3mm Tissue Punch Locator Drill Initial drill ø 2.6 mm drill MC-3003M
MC-3003L
Ratchet Adapter

MAX - TAPER / MAX - O-BALL FOR DENSITY D2/D3

2.3mm
Full Length of implant

4.8mm
3.8mm
Insertion Torque:
800 - 1000 rpm

100 - 750 rpm

35 - 45 ncm

ø3.2 ø3.0

2.5mm 2.5mm
ø3.0 ø3.0

4 mm
9mm 9mm
11mm 11mm
13mm 13mm
15mm 15mm

TCP - 3mm CT-2020 CT-1720E MC-3003S


3mm Tissue Punch Locator Drill Initial drill MC-3003M
ø3.0 ø3.0 MC-3003L
Ratchet Adapter

28
MONOBLOCK Implant

Explanation of Drill Marking


• The drill markings do not include the point of the drill.
D1/D2 Additional steps • The point of the drill is 0.4 mm long, thus the drill marking of
7 mm is actually 7.4 mm from the very tip to the bottom of
the first black line.
• The implant should be set approximately 1 mm sub crestally,
Full Length of implant

Insertion Torque:
thus for a 13 mm implant, one should drill to the 14 mm.
100 - 750 rpm

100 - 500 rpm

The use of metal stop is recommended.


35 - 45 ncm

15.5 mm
ND-1726E EL-3138 MC-3003S 15 mm
ø 2.6 mm drill ø 3 mm MC-3003M
Counterbore MC-3003L
Ratchet Adapter 13.5 mm
13 mm

11.5 mm
11 mm

D1/D2 Additional steps 9.5 mm


9 mm

7.5 mm
7 mm
Full Length of implant

Insertion Torque:
100 - 750 rpm

35 - 45 ncm

ND-1726E MC-3003S
ø 2.6 mm drill MC-3003M
MC-3003L
Ratchet Adapter 0 mm

-0.4 mm

29
30
MINI Implant

31
English version

REV.05/05-2022

Go to Follow us

Via Cesare Battisti n. 2 - 40123, Bologna - ITALY


Tel. +39 051 6661817 - info@c-tech-implant.com
www.c-tech-implant.com c-tech-implant.com Facebook Instagram Linkedin
GS
GUIDED
SURGERY
GUIDED SURGERY

IMPL ANTOLOGY MEETS PRECISION

The C-Tech/C-Guide guided surgery concept is a


comprehensive system which of fers a complete
guidance for the 4 dif ferent diameters of the EL
family: 3.1mm, 3.5mm, 4.3mm and 5.1mm, as well
as full guidance and depth control on all implant
lengths. In combination with the well proven EL
implant system, C-Guide delivers surgical precision
with long term esthetic success and predictability.

The ease of use of the C-Guide system is


demonstrated by the possibility to choose between
two dif ferent sleeve diameters: narrow and wide.
Narrow sleeves are designed for implants with a
diameter of 3.1mm and 3.5mm, while wide sleeves
are for implants with diameters of 4.3mm and
5.1mm. The sleeves are flattened on one side so
as to allow a closer placement of adjacent sleeves
within the guide.
Implant diameters within the system can be driven
with drivers and mounts.
To ensure stability and precision, the mounts are
used to lock the first 3 implants into position,
providing added stability for placement of the other
implants in the guide.

Whereas most systems are based on a single


of fset of 9mm, the GS system of fers three of fset
options. In many cases, such as a deep seating of
the implant or a thick gingiva, this standard of fset
cannot accept these aspects, making the fully
guided surgery dif ficult or even impossible.

The GS system of fers the standard 9mm of fset as


well as 11mm and 13mm. This of fset variability, in
addition to full guidance with four dif ferent implant
diameters, makes the GS system among the most
flexible and complete as well as ensuring that the
practitioner is not limited in his/her case selection.

3
SURGICAL PROTOCOL

GUIDE POSITIONING
The guide is positioned on the
jaw of the patient, using existing
dentition as stabilizer.

FIXATION PINS
In the case of an edentulous jaw, the
guide is positioned and then fastened
in place using lateral pins.

1B

USE OF THE TISSUE


PUNCH
The appropriate tissue punch is
used in a handpiece in order to
remove the gingival tissue above
the osteotomy site.

4
GUIDED SURGERY

RIDGE PROFILER/
FL ATTENER (optional)
In the case that the ridge is sharp,
one can use the ridge flattener
to create a level sur face and
facilitate the use of the locator
drill.

LOCATOR DRILL
The locator drills are used as
a starting point to prevent the
possibility of drill slipping on the
crest.

PILOT DRILL
The 2.1mm pilot drill is used to
perform the osteotomy to its final
depth. To ensure a continuous
engagement with the sleeve during
the initial drilling, the first 2.1mm
pilot drill to be used must be the
shortest one, regardless of the final
length to be achieved. For example,
in a narrow sleeve case, the first is
the drill
GS-N2007 , while in wide sleeve
cases the first one is the drill
GS-W2007.
5

5
SOFT BONE
The 3.5 mm drill will follow the
pilot drill and stop at the same
depth.

HARD BONE
In case of a 3.5mm implant to be
placed in soft bones, the 3.5mm drill
will be the final drill. Instead, in case
of hard bone, the 3.5mm drill will be
followed by the 3.5mm hard bone drill.

IMPL ANT
The implant is removed from the
vial using the implant driver or
implant driver/mount.

6
GUIDED SURGERY

IMPL ANT INSERTION


The implant is carried to the site
using the driver or mount/driver.

MANUAL DRIVER
Once the implant has been placed
in its site, it can be manually
driven using the finger adapter.
It may also be driven by the
hand-piece using the latch drivers
or by the ratchet through the
adapters or mount/drivers.

10

RATCHET ADAPTERS
The implant latch drivers can be
converted into finger drivers and
into ratchet adapters using the
CT-E7003 finger adapter which fits
onto the top of the latch.

10B

7
OFFSET VARIABILITY
OPTIONS
The GS kit of fers 3 dif ferent of fset
positions on its implant insertion
tools.
In the case that the user needs a
greater distance from the top of
the sleeve to the bone level than
the default 9mm, the GS insertion
tools of fer 2 more options; that of
11mm and 13mm.

11

CORRECT POSITION
The implant is seated in its final
position once the mount shoulder is
flush with the top of the sleeve and
the lines on the top of the shoulder
are aligned with the lines on the top
of the sleeve. These lines represent
the center of the flat sides on the
implant’s internal hex.

12

8
GUIDED SURGERY

GUIDED SURGERY COMPONENTS

Sleeves Lateral pins

x4
GS-NS x10 GS-WS x10
Sleeve for Sleeve for GS-PIN
3.1/3.5 4.3/5.1

Drill for lateral pins Lateral sleeves

x4
GS-LS
GS-FIXDRILL

Lateral Fixation Set Driver extender

x2 x4 x4
GS-2000
GS-FIX

Drivers/Mounters Wide Ratchet Driver

Fits Implants 4.3/5.1


GS-N7007/31 GS-N7007/38 GS-W7007 GS-E7001
for implants 3.1 for implants 3.5 for implants 4.3/5.1

Ratchet Driver Long - variable offset Ratchet Driver Long - variable offset

For narrow sleeves For wide sleeves


GS-N7031 GS-N7035 GS-W7001L
for implants Ø 3.1 for implants Ø 3.5 for implants Ø 4.3/5.1

9
Latch Driver

CT-E7003 GS-N9031 GS-N9035 GS-W904351


Finger adapter Fits Implants 3.1 Fits Implants 3.5 Fits Implants 4.3/5.1

Latch Drivers Long/Variable offsets

GS-N9031L GS-N9035L GS-W904351L


Fits Implants 3.1 Fits Implants 3.5 Fits Implants 4.3/5.1

Contre Angle Extractor

GS-6061

GUIDED SURGERY DRILLS

Initial Narrow Sleeve Punch + Initial Wide Sleeve Punch +


Locator Drill + Profiler Locator Drill + Profiler

GS-NPUNCH GS-NLOCATOR GS-NPRO GS-WPUNCH GS-WLOCATOR GS-WPRO

10
GUIDED SURGERY

Narrow Drills

Narrow Sleeve Drills 2.1

GS-N2007 GS-N2009 GS-N2011 GS-N2013 GS-N2015

Narrow Sleeve Drills 3.1

(real Ø2.6 mm)

GS-N3009 GS-N3009HB GS-N3011 GS-N3011HB GS-N3013 GS-N3013HB GS-N3015 GS-N3015HB

Narrow Sleeve Drills 3.5

(real Ø3.3 mm)

GS-N3509 GS-N3509HB GS-N3511 GS-N3511HB GS-N3513 GS-N3513HB GS-N3515 GS-N3515HB

11
Narrow Drills Ø2.1 Narrow Drills Ø3.1 Narrow Drills Ø3.5
L. 7/9/11/13/15 L. 9/11/13/15 L. 9/11/13/15

Narrow Punch

Narrow Profiler

Narrow Locator

Prosthetic Latch
Driver

Extractor

Torque Wrench
Short and Long

Latch Drivers
Long Ø3.1/3.5

Hard Bone Drills Narrow Ø3.1


L. 9/11/13/15

Ratchet Drivers Hard Bone Drills Narrow Ø3.5


Long Ø3.1/3.5 L. 9/11/13/15 Latch Drivers Mounters Driver Finger
Ø3.1/3.5 Ø3.1/3.5 Extender Adaptor

12
GUIDED SURGERY

Lateral Pins Drill Wide Profiler

Lateral Pins Wide Punch


x3 Wide Locator

Wide Drills Ø2.1


L. 7/9/11/13/15

Wide Drills Ø3.5


L. 7/9/11/13/15

Wide Drills Ø4.3


L. 7/9/11/13/15

Wide Drills Ø5.1


L. 7/9/11/13/15

Hard Bone Drills Wide Ø4.3


L. 7/9/11/13/15

Hard Bone Drills Wide Ø5.1


L. 7/9/11/13/15

Ratchet Latch Driver Latch Driver Wide Ratchet Mounters 3x


Driver Long Long Driver Ø4.3/5.1

13
Wide Drills

Wide Sleeve Drills 2.1

GS-W2007 GS-W2009 GS-W2011 GS-W2013 GS-W2015

Wide Sleeve Drills 3.5

(real Ø3.3 mm)

GS-W3507 GS-W3509 GS-W3511 GS-W3513 GS-W3515

Wide Sleeve Drills 4.3

(real Ø4 mm)

GS-W4307 GS-W4307HB GS-W4309 GS-W4309HB GS-W4311 GS-W4311HB GS-W4313 GS-W4313HB GS-W4315 GS-W4315HB

Wide Sleeve Drills 5.1

(real Ø4.8 mm)

GS-W5107 GS-W5107HB GS-W5109 GS-W5109HB GS-W5111 GS-W5111HB GS-W5113 GS-W5113HB GS-W5115 GS-W5115HB

14
GUIDED SURGERY

GUIDED SURGERY DRILLS AND SEQUENCE

Narrow

9mm 9/11/13mm
Offset Offset

Ø3.1

Punch Narrow Locator Ø2.1 Ø3.1 Ø3.1HB Ø3.1 Ø3.1 Ø3.1


Profiler Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet

9mm 9/11/13mm
Offset Offset

Ø3.5

Punch Narrow Locator Ø2.1 Ø3.1 Ø3.5 Ø3.5HB Ø3.5 Ø3.5 Ø3.5
Profiler Drill Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet

15
Wide

9mm 9/11/13mm
Offset Offset

Ø4.3

Punch Wide Locator Ø2.1 Ø3.5 Ø4.3 Ø4.3HB Ø4.3/5.1 Ø4.3/5.1 Ø4.3/5.1
Profiler Drill Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet

9mm 9/11/13mm
Offset Offset

Ø5.1

Punch Wide Locator Ø2.1 Ø3.5 Ø4.3 Ø5.1 Ø5.1HB Ø4.3/5.1 Ø4.3/5.1 Ø4.3/5.1
Profiler Drill Drill Drill Drill Drill Short Latch Long Latch Driver/Mount
or Ratchet

16
GUIDED SURGERY

C-GUIDE KIT GS-SURKIT

* The kit has the space to accomodate the screw driver EL-3016 and the fixed ratchet MC-00376. These two items are not included in the kit but can be purchased separately.
The torque ratchet CT-8010 is already included in the kit. The latch extractor (GS-6061), the drill for fixing lateral pins (GS-FIXDRILL) and the 3 lateral pins (GS-PIN) are included in the kit.

17
INSTRUMENTS INCLUDED IN THE C-GUIDE KIT

Narrow punch GS-NPUNCH Driver Ratchet GS-N7031 Drill D5.1 L9 HB GS-W5109HB


Long D3.1
Narrow Profiler GS-NPRO Drill D5.1 L11 HB GS-W5111HB
Driver Ratchet GS-N7035
Locator Drill GS-NLOCATOR Long D3.1 Drill D5.1 L13 HB GS-W5113HB
Drill D2.1 L7 GS-N2007 Wide punch GS-WPUNCH Drill D5.1 L15 HB GS-W5115HB
Drill D2.1 L9 GS-N2009 Wide Profiler GS-WPRO Mount D4.3/D5.1 GS-W7007
Drill D2.1 L11 GS-N2011 Locator Drill GS-WLOCATOR Latch Driver
GS-W904351
D4.3/5.1
Drill D2.1 L13 GS-N2013 Drill D2.1 L7 GS-W2007
Latch Driver Long
Drill D2.1 L15 GS-N2015 GS-W2009 GS-W904351L
Drill D2.1 L9 D4.3/5.1
Drill D3.1 L9 GS-N3009 Drill D2.1 L11 GS-W2011 Ratchet Driver
GS-E7001
Drill D3.1 L11 GS-N3011 D4.3/5.1
Drill D2.1 L13 GS-W2013
Drill D3.1 L13 GS-N3013 Ratchet Driver Long
Drill D2.1 L15 GS-W2015 GS-W7001L
D4.3/5.1
Drill D3.1 L15 GS-N3015 Drill D3.5 L7 GS-W3507
Driver Extender GS-2000
Drill D3.1 L9 HB GS-N3009HB Drill D3.5 L9 GS-W3509
Lateral Pins GS-PIN
Drill D3.1 L11 HB GS-N3011HB Drill D3.5 L11 GS-W3511
Ratchet driver GS-E7001
Drill D3.1 L13 HB GS-N3013HB Drill D3.5 L13 GS-W3513
Torque wrench CT-8010
Drill D3.1 L15 HB GS-N3015HB Drill D3.5 L15 GS-W3515
Drill for later pins GS-FIXDRILL
Drill D3.5 L9 GS-N3509 Drill D4.3 L7 GS-W4307
Finger adapter CT-E7003
Drill D3.5 L11 GS-N3511 Drill D4.3 L9 GS-W4309
Ratchet short
CT-8051
Drill D3.5 L13 GS-N3513 Drill D4.3 L11 GS-W4311 screwdriver
Drill D3.5 L15 GS-N3515 Drill D4.3 L13 GS-W4313 Ratchet long
CT-8052
screwdriver
Drill D3.5 L9 HB GS-N3509HB Drill D4.3 L15 GS-W4315
Latch screwdriver BL-9019
Drill D3.5 L11 HB GS-N3511HB Drill D4.3 L7 HB GS-W4307HB
Latch Extractor GS-6061
Drill D3.5 L13 HB GS-N3513HB Drill D4.3 L9 HB GS-W4309HB
Drill D3.5 L15 HB GS-N3515HB Drill D4.3 L11 HB GS-W4311HB
Mount D3.1 GS-N7007/31 Drill D4.3 L13 HB GS-W4313HB
Mount D3.8 GS-N7007/38 Drill D4.3 L15 HB GS-W4315HB
Latch Driver GS-N9031 Drill D5.1 L7 GS-W5107
D3.1
Drill D5.1 L9 GS-W5109
Latch Driver GS-N9035
D3.5 Drill D5.1 L11 GS-W5111

Latch Driver GS-N9031L Drill D5.1 L13 GS-W5113


Long D3.1
Drill D5.1 L15 GS-W5115
Latch Driver GS-N9035L
Drill D5.1 L7 HB GS-W5107HB
Long D3.5

18
C-GUIDE REDUCED KIT GS-SURKIT02

INSTRUMENTS INCLUDED IN THE C-GUIDE KIT


Narrow punch GS-NPUNCH Wide punch GS-WPUNCH
Locator Drill GS-NLOCATOR Locator Drill GS-WLOCATOR
Drill D2.1 L9 GS-N2009 Drill D2.1 L7 GS-W2007
Drill D2.1 L11 GS-N2011 Drill D2.1 L9 GS-W2009
Drill D2.1 L13 GS-N2013 Drill D2.1 L11 GS-W2011
Drill D2.1 L15 GS-N2015 Drill D2.1 L13 GS-W2013
Drill D2.1 L15 GS-W2015
English version

REV. 05/02-2022

Go to Follow us

Via Cesare Battisti n. 2 - 40123, Bologna - ITALY


Tel. +39 051 6661817 - info@c-tech-implant.com
www.c-tech-implant.com c-tech-implant.com Facebook Instagram Linkedin
GTR
CENTURY
CENTURY GTR

The Structure of Regeneration


Nano-structured bio-mimetic hydroxyapatite

The C-Bone synthetic bone substitutes line is based on bio-mimetic and nano-
structured hydroxyapatite. C-Bone hydroxyapatite is a calcium phosphate
biomaterial that is very similar to the human bone structure, composition and size
of nano-crystals. The Ca/P ratio of 1.67 is almost identical to that of human bone
apatite. C-Bone is available in 4 different formats: dense granules, porous chips,
injectable paste and moldable crunch, in a wide range of sizes.

C-Bone is a bio-mimetic bone Complete biocompatibility


substitute. Its high surface/volume
ratio makes it an ideal scaffold for
Highly porous and interconnected
osteointegration and regeneration of structure to support optimal
bone defects. The highly porous and osteoconduction
interconnected structure is ideally High surface/volume ratio for a
osteoconductive, promoting cellular better biological response
colonization, nutrient exchange and
an early vascularization. Excellent chemical-physical
Thanks to specific composition stability
and nano-metric dimension of
Complete remodeling in
composing crystals, C-Bone bone
physiological times
substitutes are completely degraded
by osteoclastic activity and
physiologically remodeled into new
vital bone tissue.
GTR

C-BONE

C-Bone Injectable Paste

CBO-PA0251 HA injectable paste 0.25 cc 1 syringe/box


CBO-PA0253 HA injectable paste 0.25 cc 3 syringes/box
CBO-PA0501 HA injectable paste 0.5 cc with tip 1 syringe/box
CBO-PA0503 HA injectable paste 0.5 cc with tip 3 syringes/box
CBO-PA1001 HA injectable paste 1 cc with tip 1 syringe/box
CBO-PA1003 HA injectable paste 1 cc with tip 3 syringes/box
Injectable Paste

Injectable paste is composed of


a high-density mixture of nano-
crystals and micro-powders of
nano-structured HA, in ready-
to-use syringes with tip, in
single or multiple packs.

C-Bone Dense Granules

CBO-D0501 HA dense granules  (0.5-1 mm) 0.5cc-0.4 gr 1 bottle/box


CBO-D0506 HA dense granules  (0.5-1 mm) 0.5cc-0.4 gr 6 bottles/box
CBO-D1001 HA dense granules  (0.5-1 mm) 1cc-0.75 gr 1 bottle/box
CBO-D1006 HA dense granules  (0.5-1 mm) 1cc-0.75 gr 6 bottles/box
CBO-D2001 HA dense granules  (0.5-1 mm) 2cc-1.50 gr 1 bottle/box
CBO-D2006 HA dense granules  (0.5-1 mm) 2cc-1.50 gr 6 bottles/box
Dense Granules
CBO-D4001 HA dense granules  (0.5-1 mm) 4cc-3.00 gr 1 bottle/box

Dense granules of nano-


CBO-D4006 HA dense granules  (0.5-1 mm) 4cc-3.00 gr 6 bottles/box
structured HA, with regular CBO-D20201 HA dense granules  (1 -2 mm) 2cc-1.50 gr 1 bottle/box
spherical shape with 500-1000
µm and 1-2 mm granulometry, in CBO-D20501 HA dense granules  (1 -2 mm) 5cc-3.75 gr 1 bottle/box
different volumes and in single
or multiple packs.
Macro-porosity
200-500 μm
Micro-porosity
2-3 μm
Nano-porosity
40-80 nm

GUIDED
TISSUE
REGENE-
RATION
GTR

C-Bone Moldable Crunch

CBO-CR0501 HA moldable crunch 0.5 cc 1 syringe/box


CBO-CR0503 HA moldable crunch 0.5 cc 3 syringes/box
CBO-CR1001 HA moldable crunch 1 cc 1 syringe/box
CBO-CR1003 HA moldable crunch 1 cc 3 syringes/box

Moldable Crunch

Moldable crunch is composed


of a high-density mixture of
nano-crystals, micro-powders
and micro-granules of
nano-structured HA, in “open-
mouth” syringes, in single or
multiple packs.

C-Bone Porous Granules

CBO-P0501 HA porous granules (0.5-1 mm) 0.5cc-0.4 gr 1 bottle/box


CBO-P0506 HA porous granules (0.5-1 mm) 0.5cc-0.4 gr 6 bottles/box
CBO-P1001 HA porous granules (0.5-1 mm) 1cc-0.75 gr 1 bottle/box
CBO-P1006 HA porous granules (0.5-1 mm) 1cc-0.75 gr 6 bottles/box
CBO-P20101 HA porous chips  (1 -2 mm) 1cc-0.75 gr 1 bottle/box
CBO-P20106 HA porous chips  (1 -2 mm) 1cc-0.75 gr 6 bottles/box
CBO-P20201 HA porous chips  (1 -2 mm) 2cc-1.50 gr 1 bottle/box
Porous Granules
CBO-P20206 HA porous chips  (1 -2 mm) 2cc-1.50 gr 6 bottles/box
Porous granules of nano- CBO-P20501 HA porous chips  (1 -2 mm) 5cc-3.75 gr 1 bottle/box
structured HA, with an irregular
shape similar to cancellous
bone chips, with 500-1000 µm
HA porous granules in a syringe with filter cap
CBO-P050S1 1 syringe/box
and 1-2 mm granulometry in (0.5-1 mm) 0.5 cc 
different volumes and in single
or multiple packs. Also available HA porous granules in a syringe with filter cap
in filter cap syringes. CBO-P050S3 3 syringes/box
(0.5-1 mm) 0.5 cc 
CENTURY GTR

The Natural Shield


Collagen membrane for GTR

C-Membrane is an absorbable membrane used for shielding the implantation


site from soft tissue infiltration, avoiding interference of non-osteogenic
tissues with bone regeneration. It is made from highly pure type I atelocollagen
of equine origin. It can be easily placed in site after bone grafting and requires
no fixation. Its 3 dimensional structure adapts to the bone graft surface and
provides a natural shield. It is consequently re-absorbed in about 4-6 weeks.

C-Membrane RS 4 to 6 weeks protection time

C-Membrane RS presents a rough


Equine type I atelocollagen
side characterized by less compact
fibers with an increased surface
area. Once positioned with the Totally safe and biocompatible
rough side in direct contact with
the recipient’s bone and the graft,
it guarantees greater stability of Easy to apply
the latter and of the membrane
itself.
Fully absorbable
• Small post-extractive socket protection
• Sinus bone access coverage in sinus lift
procedures
• Protection of peri-implant bone defects
• Closure of small tears of the sinus
membrane
• Restoration of small bone dehiscences
GTR

C-MEMBRANE

C-Membrane offers a wide range of different formats of collagen membranes,


available in single and multiple packages.

Collagen Membranes
CTM-15201 15 x 20 x 0.2 mm 1 pc
CTM-15206 15 x 20 x 0.2 mm 6 pcs
CTM-152010 15 x 20 x 0.2 mm 10 pcs
CTM-20201 20 x 20 x 0.2 mm 1 pc
CTM-120206 20 x 20 x 0.2 mm 6 pcs
CTM-202010 20 x 20 x 0.2 mm 10 pcs
CTM-25251 25 x 25 x 0.2 mm 1 pc
CTM-25256 25 x 25 x 0.2 mm 6 pcs
CTM-252510 25 x 25 x 0.2 mm 10 pcs
CTM-20301 20 x 30 x 0.2 mm 1 pc
CTM-20306 20 x 30 x 0.2 mm 6 pcs
CTM-203010 20 x 30 x 0.2 mm 10 pcs
CTM-30401 30 x 40 x 0.2 mm 1 pc

Collagen Membranes RS (Rough Side)


CTM-2020RS 20 x 20 x 0.2 mm 1 pc
CTM-2525RS 25 x 25 x 0.2 mm 1 pc
CTM-2030RS 20 x 30 x 0.2 mm 1 pc
CTM-3040RS 30 x 40 x 0.2 mm 1 pc
1:1 Scale drawings

15 x 20 x 0.2 mm 20 x 20 x 0.2 mm 25 x 25 x 0.2 mm 20 x 30 x 0.2 mm 30 x 40 x 0.2 mm


CENTURY GTR

The Biocompatible Tissue Substitute


Natural bone hydroxyapatite

C-Bone X is the line of natural bone substitutes of equine origin developed


through the EstRem process (Esterification Cell-Removal Technology). This
innovative “tissue processing” allows to treat all connective tissues of animal
origin and obtain totally biocompatible tissue substitutes, preserving the
biological characteristics fundamental for the regeneration process.

Its excellent osteoconductive properties allow the formation of new


vascularized bone tissue between the spaces of its porous structure and
the intergranular ones, allowing a rapid and complete osseointegration of the
grafts.

Elimination of all organic components

Preservation of only the bone mineral in the form of natural hydroxyapatite

Completely safe and biocompatible fabric

Excellent osteoconduction and maintenance of the implant volume

Excellent bone integration, slow resorption and long stay in the implant site

Practical and clean graft management thanks to the filter-cap syringe


GTR
Indications

C-Bone X, by virtue of the slow reabsorption of natural hydroxyapatite crystals,


is indicated in all those cases where the resorption of the graft is to be
limited or delayed to maintain its volume over time in a stable manner.

• Sinus lifts
• Small and large bone increases also in association with autologous grafts,
to limit their resorption
• Filling of extraction sockets

C-Bone X is available in a wide range of formats, in single and multiple packs.

C-BONE X

C-Bone X Porous Granules (0.5-1 mm)

CXA-S001 Apatite cancellous granules (0.5-1 mm) 0.5 cc 1 pc


CXA-S006 Apatite cancellous granules (0.5-1 mm) 0.5 cc 6 pcs
CXA-S011 Apatite cancellous granules (0.5-1 mm) 1.0 cc 1 pc
CXA-S016 Apatite cancellous granules (0.5-1 mm) 1.0 cc 6 pcs
CXA-S021 Apatite cancellous granules (0.5-1 mm) 2.0 cc 1 pc
CXA-S026 Apatite cancellous granules (0.5-1 mm) 2.0 cc 6 pcs
Porous Granules (0.5-1 mm)
CXA-S041 Apatite cancellous granules (0.5-1 mm) 4.0 cc 1 pc
Apatite cancellous granules with
500-1000 µm granulometry,
available in different volumes
and in single or multiple packs.
ANIMAL
ORIGIN
BONE SUB-
STITUTE
GTR

C-Bone X Porous Granules (1-2 mm)

CXA-S111 Apatite cancellous chips (1-2 mm) 1.0 cc 1 pc


CXA-S116 Apatite cancellous chips (1-2 mm) 1.0 cc 6 pcs
CXA-S121 Apatite cancellous chips (1-2 mm) 2.0 cc 1 pc
CXA-S126 Apatite cancellous chips (1-2 mm) 2.0 cc 6 pcs
CXA-S141 Apatite cancellous chips (1-2 mm) 4.0 cc 1 pc

Porous Granules (1-2 mm)

Apatite cancellous granules with


1-2 mm granulometry, available in
different volumes and in single or
multiple packs.

C-Bone X Porous Granules in filter cap syringe

Apatite cancellous granules in filter


CXA-S001S 1 syringe/box
cap syr. (0.5-1 mm) 0.5 cc
Apatite cancellous granules in filter
CXA-S003S 3 syringes/box
cap syr. (0.5-1 mm) 0.5 cc

Porous Granules in filter cap


syringe

Apatite cancellous granules with


500-1000 µm granulometry in
syringe, available in single or
multiple packs.
English version

REV. 02 / 11-2021

Via Cesare Battisti n. 2 - 40123, Bologna - ITALY


Tel. +39 051 6661817 - info@c-tech-implant.com
www.c-tech-implant.com
1 ONE TIME
CLEVER
Concept
Intro
In most implant placement procedures, it is conventional
to use a healing abutment for the healing phase. Once
completed, the healing abutment is removed to allow
placement of the final abutment. Unfortunately, a gingival
attachment often forms on the healing abutment which is
torn away upon removal. This can scar the tissue and hinder
the healing of the same tissue around the final abutment.

The ONE TIME concept addresses this problem by not


requiring the removal of the healing element. The healing
abutment instead of being removed, simply converts itself
into the base of the abutment after the healing process has
been completed. The initial gingival seal created with the
healing abutment is maintained.

The surgery is simplified by top-down planning. The


measurement of the gingival thickness is made and
depending on this, the choice of one of the 2 gingival
sleeves is taken. The drilling of the osteotomy is
consequently done from the top of the gingiva.
The prosthetic procedure is simplified. The traditional
impression transfer component eliminated. The healing
abutment is never removed and the transfer is taken with a
cap from the top of the healing sleeve.

3
Advantages

• Only one measurement is taken

• The surgical procedure is separated from the


prosthetic procedure

• Only one anesthetization is required during the entire


workflow 1X

• One-time sealing of the gingiva. The gingiva is never


torn from the healing abutment

• Completed & Sealed! During the rest of the prosthetic


treatment, the seal to the gingiva and the ONE TIME
base is never broken

• Ideal for implantology beginners

• Simplifies the collaboration between surgeons and


prosthodontists

4
1 ONE TIME CLEVER Concept

5
Step 1

Measure + Calculate
The aim of the concept is to maintain the thickest possible
gingiva. A height of 3 mm is considered to be ideal. The
implant should be placed 1 mm subcrestally.

That is why the overall depth is also determined by


the gingiva. It follows that the tissue punching offers
advantages in the concept. This can easily be done using
guided surgery.

Deep implant + desired gingival height


e.g. 13 mm implant length = 17 mm
Measured from the gingiva.

Step 2

Implantation

1 2
Instead of raising a flap, in most
cases the surgical procedure
will be initiated by using a tissue
punch to create a mucotomy. (Pic
1)

After inserting the implant,


the ONE TIME concept is used
immediately, so that the wound
does not have to be completely
sutured. (Pic 5)

3 4 5

6
1 ONE TIME CLEVER Concept

GS-WPUNCH CT-2020 CT-1720E NND-1726E CT-1735E CT-1743E BL-E7001L EL-ONE TIME GS2/ EL-ONE TIME GS2/ EL-ONETIME-BASE
Wide punch Locator Drill 2.0mm Drill 3.1 mm drill 3.5 mm Drill 4.3 mm Drill Implant EL-ONE TIME GS3 EL-ONE TIME GS3 Titanium Base
(Outer Ø 2.0mm) (Outer Ø 2.6 mm) (Outer Ø 3.1mm) (Outer Ø 3.9mm) ratchet driver Titanium healing Titanium healing
abutment abutment

ø4.3

5 mm

ø2.15

Step 3

ONE TIME - Cover screw

The gingival sleeve is placed in the implant and fastened with the cover screw.
The final position of the cover screw is slightly below the level of the gingiva.

The cover screw is tightened to 30 Ncm, then loosened again and then tightened
to 15 Ncm.

Explanation There is a Morse taper connection between the implant and the
abutment. Therefore, the cover screw must be tightened to the final position so
that the gingival sleeve can be placed into the final position.

7
Healing phase

During the healing phase, the gingiva forms around the healing screw, bonding
tightly.

Step 4 (post-healing)

Prosthetics

After complete healing, the cover screw is removed. No anesthesia is required for
the impression.

After the gingiva has completely


healed and the implant has
osseointegrated, the cover screw
is removed, the titanium base is
placed on the gingival sleeve and
tightened to 30 Ncm.

8
1 ONE TIME CLEVER Concept

Recall should be done and checked and, if necessary, the internal screws should
be re-tightened to 30Ncm.

Digital/Conventional Impression

Digital Impression

The impression can be taken digitally or


conventionally with a closed tray.

Conventional Impression

9
Pros

• Up to 30 degrees of divergence

• Morse taper connection

• Although subcrestal, there is a clean seal between the


abutment and the implant in the critical area

• After healing, it is easy to make a final decision as to


whether you have enough gingiva for the ONE TIME
gingival sleeve or whether you would prefer to use the
conventional 1-2 mm abutments from the standard
catalog

• The ONE TIME gingival sleeve has a double funtion: as


healing abutment and as a support for the titanium
base

30°

10
1 ONE TIME CLEVER Concept

One Time Clever System


D

Titanium healing abutment Includes prosthetic screw L

L D C Fixture item#
5.5 2 EL-ONE TIME GS2 EL-ONETIME GS2 EL-ONETIME GS3
4.5 h2 h3
6.5 3 EL-ONE TIME GS3

TIGHTENING: with torque ratchet 10 Ncm


Material: Titanium grade 5

Titanium Base L

L D
6.75 4.5
EL-ONETIME-BASE
TIGHTENING: with torque ratchet 25 Ncm
Material: Titanium grade 5

Transfer cap L

L D
6.5 8
EL-ONETIME-CAP
Material: PEEK

L
Laboratory analog

L D
12.5 4.5

Material: Titanium grade 5 EL-ONETIME-LAB

Holder

EL-ONETIME-HOLDER

11
CAD-CAM Components
D

L
Titanium CEREC® bases Includes prosthetic screw BL-5052HX
C

L D C Fixture item#
1 BL-6047
BL-6047 BL-6047H2 BL-6047H3
4.65 4.25 2 BL-6047H2
H1 H2 H3
3 BL-6047H3

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

Scan body for CEREC® bases L

L D
6.55 4.8
BL-6047/1 BL-6047/2
Material: Plastic for Omnicam for Bluecam

Non rotating CEC titanium bases Includes prosthetic screw BL-5052HX


C

L D C Fixture item#
1 EL-6041
5 4.2 2 EL-6042 EL-6041 EL-6042 EL-6043
3 EL-6043 H1 H2 H3

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

Rotating CEC titanium bases Includes prosthetic screw BL-5052HX


C

L D C Fixture item#
1 EL-6041R EL-6041R EL-6042R EL-6043R
5 4.2 2 EL-6042R H1 H2 H3
3 EL-6043R

TIGHTENING: with torque ratchet 25 Ncm


Material: Titanium grade 5

12
English version

REV. 01/02-2022

Go to Follow us

Via Cesare Battisti n. 2 - 40123, Bologna - ITALY


Tel. +39 051 6661817 - info@c-tech-implant.com
www.c-tech-implant.com c-tech-implant.com Facebook Instagram Linkedin