ae ‘CONFIDENTIAL NOV 2015/EPE49: S - FACULTY OF MECHANICAL ENGINEERING UiTM, SHAH ALAM TEST 1 ‘COURSE : ELECTRICAL POWER AND MACHINES COURSE CODE : EPE491 | TEST 5 NOVEMBER 2015 TIME 4.5 HOURS, INSTRUCTIONS TO CANDIDATES: 1. This test paper consists of 4 questions with a maximum total of 30 marks. 2. Answer ALL questions. 3. Start answering each question on a new page. 4, Please attach this cover page with your answer script. FILL IN THE FOLLOWING PARTICULARS: 1. Name 2. IDUITM 3. Group 4, Lecturer ESEGSS TEST 1 QUESTION | MAXIM _| GRADED MARKS ai 6 e | | @ | 4 g 3 10 | The Qa 10 22 [Tora —_[ 30 D0 DO NOT TURN THIS PAGE UNTIL YOU ARE TOLD TO DO SO This test paper consists of 3 printed pages 1 CONFIDENTIAL NOV 2015/EPE491 QUESTION 1 A single phase circuit is depicted in the following Figure 1. The supply rms mode is “BOV with 60Hz frequency. Calculate the corresponding capacitance value that is needed to improve the circuit power factor to 0.89 lagging. Show the answer through the aid of phasor diagram (6 marks) V=480Vrms Figure 4 QUESTION 2 {A ferromagnetic core is shown in Figure 2. Four sides of this core are of uniform ‘width. The depth of the core (in to page) is 10cm, and the other dimensions are shown in the figure. There is a 250-tum coil wrapped around the left side of the core. ‘Assuming relative permeability [- of 1900, how much flux will be produced by @ 1.64 input current? (4 marks) Figure 2: Ferromagnetic Core CONFIDENTIAL NOV 2015/EPE491 QUESTION 3 ‘A 240-V, 3 power system is shown below. It consists of an ideal 240-V, Y- connected 36 generator connected through a 36 transmission line to a Y-connected load. The transmission line has an impedance 0.09 + j0.25 per phase and the load has an impedance of 9 + 6 0 per phase. 0,09 +0250 | Wa 0.09+)0259 | | ARTES \ | 240v sien @ | sons eee Find a, Draw and label a per-phase circuit b. The magnitude of the line current I, : c. The magnitude of the transmission line voltages d. The real, reactive and apparent powers consumed by the load sicaas . The power factor of the load load (10 marks) QUESTION 4 A transformer has the following details: 20kVA, 8000/415V, 60Hz. The open circuit test and short circuit test were performed on the primary side of the transformer, and the following data were taken: Open-circuit test (on primary) | Short-circuit test (on primary) Voc = 6000V Vsc = 330V. loc = 0.14. Isc = 1.54 Pog = 240W. Pro = 110W. Find the impedances of the approximate equivalent circuit referred to the primary side, Calculate R; and X;, if Ro=0.120, X2=0.50. (10 marks) END OF QUESTION PAPER 3 i pumapseuye pare = (eo(y + 620:5 vaa hE “= 630-8 -26 6-74 ea eee 526 ge. #3 58-75 var Gy a — ts oe see if Vz lov (parallel) Vow. ws ane * ‘esersS = 346-99 __ Ceey (476-79) c =2-976 r0% 72896 ME Question 2 _[depty_» (Cer) 2-4 Sere) (0815) Fois-el A aa " A = Gem K loom \s 6010-61 $2 58 4e x0? Wy ye Sag ee —A>——£$ iti fransmission tne 6-09 4 302Sm ise eg cee z wo se [Coerejersd eae Z Fo i [dike | QURP shy EV ee Mg Ty ee _ Te Csewes? leita oe eee ¥56,) (2456) xo z ee 324 eee A pepe Ten aa (0:09 450-35) S725 c0e%° vy 4) PR 23Mp Ty tos Cua a He Me We ey ce dean a > 335-329 L-o-w* 2 eee ‘t- ine / : Question 4 4 .- || Se soya | sd Mi Boca 'w 4 Na 24s Vv 7 Sy ree Oe sen iit i = det lun eos : sauna Has ae eee 7 eee C2 icone) sie | 240 B40 = Bo00 (2-5 PV Tu cos O cos @ = | ie Gp? Kee > Tm + Teena FO-) sia 84312 nat OEE we costevonery com me ft | ce é Gare Z Tt: 2-349 A ie i aa i eaeaece r f 7 2S vsaes eG peer Beg? 2200 Ves Me > 14-294 Cais) (9-297)" (es) ve (85-903 Vituimsteay = Te! Beg 4 M5" 2 got +399 (4u-S74} 185-803) 4S8 372 V Y= S2 FAY A458 3F2 rain ge PRIA vo osnesevcon oy

You might also like