≤ 1.5(SD) (≤20×109/L)^ ≤
PLT* 0-5000×109 /L ≤ 1.0%
2.5% (≥100×109/L)^
Sample Type Analysis Mode
≤15% (RBC ≥ 3.00×1012/L
CBC, CBC + DIFF, CBC + DIFF+RET*, CD + ESR, RET* 0-0.8×1012/L ≤ 1.0%
Whole blood RET%: 1.00% ~ 4.00%)
CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*,
and other modes ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0%
Predilute CBC, CBC + DIFF, CDR*, and other modes Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models
CBC + DIFF
Items marked with an aerisk (*) apply only to BC-780
www.mindray.com
P/N:ENG-BC-760 & BC-780 ESR-210285X6P-20220115
©2021 Shenzhen Mindray Bio-Medical Electronics Co., Ltd. All rights reserved.
BC-760 & BC-780 Auto Hematology Analyzer with ESR BC-760 & BC-780 Auto Hematology Analyzer with ESR
Above your expectations Beyond your expectations
SF Cube fluorescent technology allows reliable counting and differentiation of Limitations of traditional PLT counting
abnormal samples
In the traditional impedance method, PLTs are subject to interferences that may lead to falsely high or falsely low results
(as shown in the figure). Once an error report is generated, it will directly affect the judgment and decision-making of
clinicians. The results reported at the clinical decision level are related to patient safety. Therefore, accurate PLT results are
critical in clinical practice.
Interference of RBC fragments
Fragment
PLT
DIFF channel RET channel
More refined and reliable cell Fragment area
Falsely high
differentiation Normal
EOS
abnormal cells, such as immature
granulocytes (IMGs), reticulocytes (RETs*), and GHOST BASO PLT-O IPF
Interference of large PLTs
0 10 20 30 fL
immature platelet fraction (IPF). PLT
Large PLTs area
Falsely low
Impedance channel
Small PLTs
Small PLTs
Volume
PLT-H
More comprehensive alarm messages Small PLTs are not interfered
for abnormalities Small PLTs (< 10 fL) are free from interferences in impedance channel
PLT-H
The analyzer provides a detailed list of over 40
prompt messages, including WBC message, RBC Scattergram of DIFF Channel Scattergram of DIFF Ghost
message, and PLT message. This allows laboratory Large PLTs
Volume
FS
Large PLTs
technicians to intuitively and quickly identify Optical PLT-H in every CD test
DIFF channel
1 2
3 4
method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.
• Great correlation with the Westergren • The integrated instrument is capable of • Report CBC + ESR results together
method both CBC and ESR detection; within 1.5 min;
Integrated CBC + ESR analyzer
• Same QC and calibrator as in the • Takes up the space of only one analyzer. • The measurement results are SF Cube 3D fluorescent platform Optical PLT-H in every CD test
BC-6000 series protected against the influence of IMG/NRBC reportable parameters Integrated RET* & body fluid analyzer
Accurate measurement of low WBC/PLT count
• Combined examination helps to avoid subjective factors; Anti-aging capability:
the interferences of dehydration, • Automation can reduce the biosafety 24h (room temperature)
48h (refrigerated transportation)
polycythemia vera and anemia on ESR hazards that may otherwise be
results introduced by a manual method.
Interactive excellence