You are on page 1of 12

Designer: Rick Thibodeau

4432 Teel Court Juneau, Alaska 99801 A Residence F o r :


email: rick.designworks@gmail.com Hoonah, Alaska
907.789.2897
www.designworksalaska.com
STRUCTURAL ANALYSIS & DESIGN BY C 2023 ALL RIGHTS RESERVED
David & Angela Wrightson C 2023 ALL RIGHTS RESERVED
February 6, 2023
JACOB GRAVES, P.E. 907.635.1433

IMPORTANT:
The designer grants the client a license to build only one structure from
the plans, and the plans cannot be resold unless by express written
authorization of Rick Thibodeau dba DesignWorks.
See 2012 International Residential Code Table R302.6.

Door from house to garage to be minimum 1 3/8" solid core wood, 1 3/8 solid or These designs and drawings are protected by the Federal Copyright
honeycomb core steel doors, or 20 minute rated per 2012 International Residential Code Sec.
R302.5.1. Laws and may not be copied, reproduced, modified, distributed or used
in any other way without the specific written consent of Rick Thibodeau
Enclosed accessible space under stairs shall have walls, under stair surface
and any soffits protected on the enclosed side with 1/2" gypsum board. IRC Sec. R302.7. dba DesignWorks, the copyright owner.

To comply with 2012 IRC R311.7 .


Max. stair rise 7 3/4"; min. stair tread 10".
GENERAL:
Provide tread nosing min. 3/4", max. 1 1/4"
Handrail height to be min. 34", max. 38" above sloped plane @ nosing. THESE PLANS ARE ONLY A GUIDE AND DO NOT PURPORT TO SHOW EVERY ASPECT
Handrails for stairways shall be continuous for the full length of the flight, from a point directly OF THE WORK REQUIRED FOR COMPLETION. IT SHALL BE THE BUILDER'S SOLE
above the top riser of the flight to a point directly above lowest riser of the flight. RESPONSIBILITY TO:
Handrail ends shall return to walls or shall terminate in newell posts or safety terminals. 1) VERIFY ALL DIMENSIONS AND FIELD CONDITIONS BEFORE PROCEEDING.
Provide 1 1/2' space between wall and handrail.
2) NOTIFY DESIGNER OF ANY DISCREPANCIES. OBTAIN APPROVAL FROM DESIGNER
Handrails with a circular cross section shall have an outside diameter of at least 1 1/4" and not
greater than 2". See IRC Sec. R311.7.7.3 #2 for non-circular handrails. OR ENGINEER FOR PROPOSED FIELD CHANGES PRIOR TO CONSTRUCTION OF
Required guards on open sides of stairway shall have intermediate rails or ornamental closures MODIFICATION.
which do not allow the passage of a sphere 4" or more in diameter. 3) NOTIFY THE LOCAL BUILDING OFFICIAL AT CONSTRUCTION STAGES REQUIRING
INSPECTION AND OBTAIN NECESSARY APPROVAL PRIOR TO COMMENCEMENT/
Minimum 24" in front and 30" wide space.
CONTINUATION OF THE WORK.

Basements, habitable attics and every sleeping room or 4) PERFORM ALL CONSTRUCTION WITH MATERIALS, METHODS, AND WORKMANSHIP
other habitable room equal to or greater than 70 square feet and not used for cooking, eating, ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY.
living room or ther dedicated non-sleeping uses shall have at least one operable emergency 5) PROVIDE ADEQUATE SHORING, BRACING, AND FORMWORK, ETC., AS REQUIRED
escape and rescue opening which shall open directly into a public way, or to a yard or court that FOR THE PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION.
opens to a public way. The units shall be operable from the inside of the room without the use of 6) FOLLOW MANUFACTURERS' RECOMMENDATIONS.
keys, tools, or special knowledge.
7) MAKE ALL PRECAUTION TO INSURE JOBSITE SAFETY.
All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet.
Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet.
The minimum net clear openable height dimension shall be 24 inches. The minimum net clear
openable width dimension shall be 20 inches. When windows are provided as a means of escape Ceiling Insulation: As shown on plans or min. R-49. Sidewalls of skylight wells to have min. wall
or rescue they shall have a finished sill height of not more than 44 inches above the floor. insulation levels of R-19. Skylight areas shall be averaged with ceiling sections to equal overall
U-value of 0.033 or less.
Safety glazing is required in doors, storm doors, railings, within 24" of a door, or when
panes are over 9 square feet and within 18 inches of the floor. (See 2012 IRC Sec. R308.4) Roof areas of enclosed rafter spaces must be ventilated. The minimum required area of the vents
is 1/150 of the area to be ventilated. See 2012 IRC Section 806 for reductions.
Safety glazing is required in any part of a building wall enclosing compartments for hot tubs,
whirlpools, saunas, steam rooms, bathtubs,and showers, where the bottom exposed edge of the Kitchens, Bathrooms and Laundry Rooms. All bathrooms, water closet compartments, laundry rooms with more than one clothes washer Wall Insulation: Rigid foam "outsulation" to comprise min. 43% of total wall R value.
glazing is less than 60 inches above any standing or walking surface. and one clothes dryer and similar rooms shall be provided with a mechanical exhaust system connected directly to the outside with a minimum rated
exhaust capacity of 50 cubic feet per minute and 100 cubic feet per minute for kitchens. Continuous ventilation from intermittent increased capacity Floor Insulation: As shown on plans or min. R-30. Floors over crawl spaces may be uninsulated if
Attic access to be provided with minimum 22" x 30" opening with a 30" min. whole-house or heat-recovery ventilation systems may be used with reduced exhaust capacity as long as an exhaust intake is located in such rooms. crawl space walls are insulated to R-15 at least 24" below grade. Rim joist in all cases insulated to
unobstructed headroom in the attic per R807.1, and crawl space access provided with minimum R-19 min.
18" x 24" opening per R408.4 of the 2012 International Residential Code. To be installed per manufacturer's requirements per UMC 504 and Tables 5A, B & C. Firestops to be
installed at all floor/ceiling chimney penetrations. Any rim joists in crawl spaces must be P.T. wood or equivalent unless covered by min. 2" foam
All wood structural members and their fasteners and connections shall inside or out, or unless the rim joist is at least 12" above grade.
conform to Section R317 of the 2012 International Residential Code. Will be installed with spark/flame minimum 18" above floor and protected from traffic per UPC 1310 and UMC Floor areas that are exposed directly to outside air are to be insulated to R-38.
508.
Smoke alarms shall be interconnected A/C with D/C backup and installed in the Concrete slab on grade floors shall have R-10 perimeter insulation from top of slab to top of
following locations: Minimum clearance space 30" wide by 36" in front by 6'-6" tall access space per NEC 110-16. Panel will not be in clothes closet, footing and then horizontally for a total distance of 4 ft.
1. In each sleeping room. along stair run or in bathrooms per NEC 240-24.
2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. Glazing: U-0.32 Maximum Required.
3. On each additional story of the dwelling. Windows and sliding glass doors are limited to 15% of the exterior wall surface in 1 and 2 family
4. In any habitable room equal to or greater than 70 square feet, and not used for cooking, eating, One on every wall section 2' or longer, and no point along wall can be more than 6' from outlet. dwellings and 25% in townhouses. Glass areas exceeding these limits may be allowed using the
living room or other dedicated, non-sleeping uses. See IRC R314 amended by Title 19.04R313.1. Kitchens: One at every 12" countertop and no more than 48" apart. building envelope requirements of the 2012 International Energy Conservation Code.
One req'd in garage which shall be at least 18" above floor if boiler or spark producing equipment present. Exterior wall area includes all vertical surfaces exposed to the weather, and includes rim joists,
Required on each floor including basement, in halls outside sleeping rooms, and One req'd in each bathroom within 3' of the outside edge of each basin. garage wall areas, and below grade warm wall areas.
inside efficiency apartments. At exterior: one in front of building and one at rear.
All pipes subject to freezing and outside conditioned areas shall be protected from freezing. R-3
All habitable rooms shall have an aggregate glazing area of not less than 8 To comply with NEC Section 210-8. To be provided at kitchens, baths, outside grade level, crawl spaces, all garage minimum insulation is recommended.
percent of the floor area of such rooms. outlets not specifically designated for a particular piece of equipment, and Jacuzzis.
Air Handling Ducts: In areas without a positive heat supply such as attics and crawl spaces shall be
Every dwelling unit shall be provided with heating facilities capable of Required in all habitable rooms per 2008 NEC Sec. 210.12 . insulated to a minimum of R-8.
maintaing a min. room temperature of 68° F at a point 3' above the floor and 2' from exterior
walls in all habitable rooms at the design temperature without involving the combustion of a solid Electrical receptacles every 6' with light, smoke detector, insulation and vapor barrier per NEC 210-52 and Title 19.10.010. If room Vapor Retarders with a perm rating of 1 or less shall be provided on the warm side of wall, ceiling
fuel. is over 70 sq. ft. and served by stairs, natural light and ventilation and egress per 2012 IRC SEC. R303 & R311. and slab insulation.
These plans and specifications are to be
considered only a guide, and they do not
1'-2" 6'-2" 1'-2" 6'-11" purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
A

1'-2"
shall be installed according to the
4'-3" 9 manufacturer's specifications.

Before construction begins, a building


permit is applied for, or materials are
3'-9 1/4" 48'-8" ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the

9'-1"
situation.
B B
The designer grants the client a license to
build only one structure from the plans, and
36" X 36" X 8" FTG. A A

1'-1 1/4"
3'-7 1/2"
the plans cannot be resold unless by
express written authorization of Rick
W/ (5) #4 BARS EA.
4 5 Thibodeau dba DesignWorks.
6 3/4" WAY, TYP.
These designs and drawings are protected
by the Federal Copyright Laws and may
not be copied, reproduced, modified,
H8 H2 H8 distributed or used in any other way without
D the specific written consent of Rick

2'-0" 2'-11 5/8"


Thibodeau dba DesignWorks, the copyright
owner.

PLACE CONTINUOUS 6 MIL POLY

Wrightson Residence
VAPOR RETARDER ON CRAWL

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
SPACE FLOOR. EXTEND VAPOR H8
11'-9 1/4"

RETARDER 6" UP FOUNDATION 2 X 6 STUD WALL W/ P.T.


WALLS AND SEAL TO STEMWALL. SOLE PLATE
PROVIDE MECH. VENTILATION. 16" X 8" CONC. FTG. W/ (2)
SEE IRC SEC. R408.3 #4 BARS CONTINUOUS
A.B.'S @ 42" O.C. 24" X 24" X 24" FTG.

6'-0"
(3) #4 BARS EA. WAY

Hoonah, Alaska
TOP & BTM., 3" CLR.

2'-0"
C H8

1'-1 1/4" 12'-5 3/4" 14'-0" 10'-2" 5'-10" 3'-11 3/4" 1'-1 1/4"

A.B.'S @ 42" O.C.


36" O.C.
35'-6 1/2"

5/8" Ø X 10" ANCHOR BOLTS

you, plans to give you hope and a future."


12'-0"

36'-8"

36'-8"
A.B.'S @36'-8"

48" O.C. & WITHIN 1'-0" OF


CORNERS & SILL ENDS UNO.
2 X 4 STUD WALL W/ P.T. USE SIMPSON LBP5/8 BEARING 2 X 6 STUD WALL W/ P.T. 2 X 4 STUD WALL W/ P.T.
SOLE PLATE PLATES UNDER BOLT NUT SOLE PLATE SOLE PLATE
16" X 8" CONC. FTG. W/ (2) 16" X 8" CONC. FTG. W/ (2) 16" X 8" CONC. FTG. W/ (2)
#4 BARS CONTINUOUS 8" X 48" H. ICF STEM WALL W/ #4 BARS CONTINUOUS #4 BARS CONTINUOUS
A.B.'S @ 48" O.C. #4 BARS @ 12" O.C. HORIZ. A.B.'S @ 48" O.C.
& #4 @ 18" O.C. VERTICAL
PROTECT FOAM ABOVE GRADE

20" X 8" CONCRETE FOOTING


C W/ (3) #4 BARS LONG. & #4
BARS @ 18" O.C. TRANS.
11'-9 1/4"

36" X 36" X 8" FTG.


W/ (5) #4 BARS EA.
WAY, TYP.

H8 H8
D
6 3/4"

3'-10 1/4"

SHEET TITLE:

A A

A 8" Ø CONC. COLUMN NOTES: DRAWN BY:


20" Ø BIGFOOT FOOTING MARK HOLDDOWN ANCHOR BOLT CHORD RICK THIBODEAU
1) ALL CONCRETE TO HAVE 3,000 PSI MIN. COMPRESSIVE
11'-9 1/4" 2'-1 3/4" 5'-8 1/2" B 10" Ø CONC. COLUMN H2 HDU2 SSTB16, 12 5/8" EMBED. (2) 2x6 POST 907.789.2897
24" Ø BIGFOOT FOOTING STRENGTH
C 12" Ø CONC. COLUMN H8 HDU8 SB7/8 X 24, 18" EMBED. (2) 2x6 POST 2) TOP PLATE SPLICE: 48" MIN LAP W/ (16) 16d NAILS DATE: Feb. 6, 2023
28" Ø BIGFOOT FOOTING
3) 2,000 PSF BEARING SOILS
FOUNDATION PLAN D 12" Ø CONC. COLUMN W/ (4) #4
VERT. W/ 12" LEG INTO FTG. & 4) HOLDDOWN ANCHOR BOLTS TO BE GALV. A307 C 2023 ALL RIGHTS RESERVED
Scale: 1/4" = 1'-0" #2 HOOPS HORIZ. @ 8" O.C.
36" Ø BIGFOOT FOOTING W/ (4) THREADED ROD W/ NUT & WASHER, 22" EMBED. OR

1
#4 HORIZ. EA. WAY SHEET
SIMPSON PER SCHEDULE.
OF 11
19'-3" 7'-4" 7'-2" These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
21 TR. @ 11" A necessary for the completion of the project.
All construction shall conform to the 2012

48'-0" 9 International Residential Code.


engineered components, systems, and
All

other manufactured items and equipment


shall be installed according to the
B manufacturer's specifications.

10'-7" 2'-9" 2'-11" 7'-9" 3'-6" 7'-4" 2'-4" 10'-10" 9 Before construction begins, a building
permit is applied for, or materials are
ordered, the building contractor, as

10'-0"
A designated by the owner, shall review the
plans. The designer's liability due to errors
4 or omissions contained within these
drawings shall be limited to the redrawing
A
Covered Porch or redesigning of the plan to address the
situation.
5

4'-1"
4'-1"
UP 22 R. @ 7" 8'-0" x 10'-0" The designer grants the client a license to
build only one structure from the plans, and
B B the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.

HANDRAIL PER IRC These designs and drawings are protected


Micro-Hood by the Federal Copyright Laws and may

3680
D W

4'-6"
not be copied, reproduced, modified,

5'-0"

(2) 3080
distributed or used in any other way without
UP 19 R. @ 7.06" the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
F owner.
E
D 11
C 11
11
Bedroom GUARDRAIL

36" REF
12'-0"

13'-8" x 10'-1" 3080

Wrightson Residence
Kitchen

13'-4"
4'-2" 4'-6"

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
10'-1" x 7'-1" A 5 TR. @ 10"

DW

2 X 6 STUDS
12 TR. @ 10"
6
Entry

10'-0"
3'-0"

68
9'-4" Mech.

28
7'-10"x
12'-6"

Hoonah, Alaska
7'-4" X 14'-1"

Cabinet
2668
48" Vanity

Linen
2468

Bath

2'-5"
7'-1"

3080
A

Living

48" x 36"
8'-0" x 6'-10"

Shower
B
18'-0" x 21'-2"

4'-8"

36'-0"
Steam Rm.
36'-0"
12'-0"

7'-4"

STAGGERED 2 X 4 STUD 7'-4" X 4'-0"

you, plans to give you hope and a future."


48" x 36"
WALL W/ 2 X 6 PLATES

Shower
M.Bedroom

BENCH

9'-2"
2'-10"
& SOUND INSULATION

3080
Bath

2 X 6 STUDS
12'-4" x 14'-0"
7'-1"
A 8'-0" x 6'-10"

48" Vanity

Cabinet
2668

Linen

4'-5"
9'-8"
7'-5"

2'-5"
8'-2" 2'-5" 2'-5" 4'-0" 1'-6" 9'-0" SHOWER
5'-0" X 10'-3"
4'-0"
3680

3'-0"
2 X 6 STUDS

4'-4"
28
12'-0"

Bedroom
68

Entry
3'-5"

7'-8" x 6'-1" 8" 13'-8" x 10'-1"


3080 Dressing

6'-6"
B
14'-8" X 7'-10"
5068

B
(2) 3068

Shelves

4'-4"
3680
3'-6"

W/D

3'-3"

WARDROBE

B B
4'-0"

5'-1" 10'-7" 9'-9" 2'-5" 5'-4" 15'-2"


SHEET TITLE:
MARK QTY. WINDOW TYPE ROUGH OPENING
STAIR CONSTRUCTION NOTES:
A 6 DOUBLE CASEMENT 6'-0" X 5'-0" 2'-0" 6'-0"
Under Stair Spaces: Enclosed accessible space under stairs shall have walls, under
B 11 CASEMENT 2'-4" X 5'-0" stair surface and any soffits protected on the enclosed side with 1/2" gypsum board.
IRC Sec. R302.7.
DRAWN BY:
C 1 DOUBLE CASEMENT 4'-0" X 4'-4"
RICK THIBODEAU
D 1 DOUBLE CASEMENT 4'-8" X 4'-4" Stairs, Handrails, & Guardrails: To comply with 2012 IRC R311.7 . 907.789.2897
1 FRENCH DOOR (3) 3080 Max. stair rise 7 3/4"; min. stair tread 10".
E
Provide tread nosing min. 3/4", max. 1 1/4"
F
1,2
1 TRAPEZOID 9'-2" X 5'-0" Handrail height to be min. 34", max. 38" above sloped plane @ nosing.
DATE: Feb. 6, 2023
Handrails for stairways shall be continuous for the full length of the flight, from a point
G3 1 CASEMENT 2'-4" X 4'-0"
FIRST FLOOR PLAN GRAPHIC SCALE directly above the top riser of the flight to a point directly above lowest riser of the flight.
H 1 FIXED 2'-4" X 5'-0" N SCALE: 1/4" = 1'-0"
Handrail ends shall return to walls or shall terminate in newell posts or safety terminals.
Provide 1 1/2" space between wall and handrail. C 2023 ALL RIGHTS RESERVED
1. TOP SLOPE 4:12
2. MATCH WIDTH TO GLASS DOOR BELOW 1,728 SQ. FT. Handrails with a circular cross section shall have an outside diameter of at least 1 1/4"

2
0' 4' 8' and not greater than 2". See IRC Sec. R311.7.7.3 #2 for non-circular handrails. SHEET
3. OPAQUE GLASS
OUTSIDE DIMENSIONS TO FACE OF SHEATHING Required guards on open sides of stairway shall have intermediate rails or ornamental
closures which do not allow the passage of a sphere 4" or more in diameter.
OF 11
These plans and specifications are to be
48'-0" considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
8'-0" 4'-4" 3'-0" 10'-6" 2'-6" 3'-10 3/4" 7'-2 1/4" 6'-11" 2'-9" 4'-0" 2'-9" 2'-0" 2'-6" other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.

A A
Before construction begins, a building
permit is applied for, or materials are
ordered, the building contractor, as
4 5 designated by the owner, shall review the
plans. The designer's liability due to errors

4'-1"
DN 22 R. @ 6.96" A or omissions contained within these
drawings shall be limited to the redrawing
B B H or redesigning of the plan to address the
situation.

The designer grants the client a license to


build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
48" x 36"

4'-6"
Thibodeau dba DesignWorks.

4'-8"
4'-0"
LP GAS Shower
FIREPLACE These designs and drawings are protected
by the Federal Copyright Laws and may

8'-0"
not be copied, reproduced, modified,
distributed or used in any other way without
the specific written consent of Rick

Bath Thibodeau dba DesignWorks, the copyright

HANDRAIL PER IRC


owner.

#3

(2) 3080
6'-3" X 13'-8"
Bedroom #3

Wrightson Residence
7'-0"

12 TR. @ 10"
2 X 6 STUDS
A

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
DN 19 R. @ 7.06"
42" VANITY

10'-0"
13'-9" x 13'-8"
Living
19'-4" X 19'-0"
VAULTED CLG.

30" Linen
10'-0"

3080

3080

Cabinet
2'-10"

Hoonah, Alaska
20
80

2'-6"
FLAT CLG.
Covered

5'-0"
B

36'-0"
36'-0"

3080

2'-6"
Deck F E

12'-0" X 36'-0" 3080

2'-9"
3080
OVENS

you, plans to give you hope and a future."


(2) 2680
Pantry
10'-0"

6'-9"
A 11'-1" x 6'-1"

10'-0"
11 6'-3 1/2" 4'-1 1/2"

48" REF
Dining B
11'-0" X 16'-2" 11
36" LINEN
A
5'-0" CABINET
Bedroom #2
96" VANITY

13'-9"
5'-6"
13'-7" x 13'-3"

Kitchen Bath #2 3080


4'-1"

C
11'-1" x 9'-3" 2680
8'-0"

10'-8" x 15'-8 11

4'-3"
DW 60" TUB
& SHWR.
RAILING PER IRC

D G A

15'-8" 6'-10" 5'-0" 1'-10" 4'-7" 6'-9" 7'-4"

SHEET TITLE:

MARK QTY. WINDOW TYPE ROUGH OPENING

6 DOUBLE CASEMENT 6'-0" X 5'-0"

N
SECOND FLOOR PLAN A
B 11 CASEMENT 2'-4" X 5'-0"
DRAWN BY:
RICK THIBODEAU
1,662 SQ. FT. C 1 DOUBLE CASEMENT 4'-0" X 4'-4" 907.789.2897
OUTSIDE DIMENSIONS TO FACE OF SHEATHING D 1 DOUBLE CASEMENT 4'-8" X 4'-4"
GRAPHIC SCALE
DATE: Feb. 6, 2023
1 FRENCH DOOR (3) 3080

3'-5 11/16"
E
5'-0"

F 1,2
F 1 TRAPEZOID 9'-2" X 5'-0"
G3 1 CASEMENT 2'-4" X 4'-0"
0' 4' 8' C 2023 ALL RIGHTS RESERVED
H 1 FIXED 2'-4" X 5'-0"

3
9'-2" 1. TOP SLOPE 4:12 SHEET
2. MATCH WIDTH TO GLASS DOOR BELOW
3. OPAQUE GLASS
OF 11
CONTINUOUS These plans and specifications are to be
RIDGE VENT considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
METAL ROOFING other manufactured items and equipment
ROOFING UNDERLAYMENT PER shall be installed according to the
manufacturer's specifications.
ROOFING MANUFACTURER
Before construction begins, a building
5/8" PLYWOOD SHTG. W/ CLIPS, permit is applied for, or materials are
STAGGER JOINTS ordered, the building contractor, as
designated by the owner, shall review the
NAIL ROOF W/ 10d @ 6" O.C. PANEL plans. The designer's liability due to errors

12 EDGES, 12" O.C. FIELD. or omissions contained within these


drawings shall be limited to the redrawing
SIMPSON H1 TIE @ EA. TRUSS END or redesigning of the plan to address the
situation.
7
The designer grants the client a license to
build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.

PRE-ENGINEERED TRUSSES 24" O.C. These designs and drawings are protected
R-60 BLOWN-IN F.G. INSUL. by the Federal Copyright Laws and may
not be copied, reproduced, modified,
6 MIL POLY V.B distributed or used in any other way without
the specific written consent of Rick
5/8" GYP. BD. Thibodeau dba DesignWorks, the copyright
4 owner.

12

Wrightson Residence
BLOCKING:

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
2 X 4 FRAME W/ PLYWD. OR
PRE-ENGINEERED TRUSS
FRAME, NAIL 4 SIDES 10d @
"REMOTE" WALL CONSTRUCTION :
6" O.C. TOENAIL ALLOWED
2 X 6 HF #2 STUDS @ 16" O.C. (STUDS >9' = HF #1 OR BTR.)
R-19 F.G. BATT CAVITY INSUL.

Hoonah, Alaska
1/2" GYP. BD. @ INTERIOR 4'-0"
15/32" EXTERIOR RATED STRUCTURAL PLYWD. SHTG.
SEE PLAN FOR SHTG. NAILING
ICE & WATER SHIELD INSTALLED OVER SHEATING.
(2) LAYERS 2" XPS FOAM BD.
R-5 PER INCH (R-20) STAGGER JOINTS

WDW. HEAD HT.


1 X 4 FURRING STRIPS FASTENED W/ 1/4" x 8" GRK CERAMIC

9'-1"
COATED SCREWS @ 12" O.C., ANGLED UP 1/2" VERTICAL PER

8'-0"
6" HORIZ. W/ 2.5" EMBEDMENT IN CENTER OF WALL STUD
SIDING PER ELEVATIONS

you, plans to give you hope and a future."


1 1/8" PLYWD. SUBFLOOR GLUED TO JOISTS &
W/ 10d NAILS 6" O.C. EDGE, 12" O.C. FIELD

2'-1 1/8"
PRE-ENGINEERED 24" DEEP
FLOOR TRUSSES @ 24" O.C.

9'-1"
1 1/8" PLYWD. SUBFLOOR GLUED TO JOISTS &
W/ 10d NAILS 6" O.C. EDGE, 12" O.C. FIELD
11 7/8" BCI/6000 1.8 JOISTS @ 24" O.C.
R-19 SPRAY FOAM INSUL. @ RIM
PROTECT FOAM ABOVE GRADE SHEET TITLE:

5/8" Ø X 10" ANCHOR BOLTS


48" O.C. & WITHIN 1'-0" OF DRAWN BY:
CORNERS & SILL ENDS UNO.
USE SIMPSON LBP5/8 BEARING
RICK THIBODEAU

4'-0"
3" CONC. SLAB W/ FIBERMESH PLATES UNDER BOLT NUT 907.789.2897
6 MIL POLY VAPOR RETARDER
2" R-TECH IV XPS FOAM BD. DATE: Feb. 6, 2023
8" X 48" H. ICF STEM WALL W/
3" WELL COMPACTED SANDY GRAVEL
#4 BARS @ 12" O.C. HORIZ.
& #4 @ 18" O.C. VERTICAL
8"
PROTECT FOAM ABOVE GRADE
C 2023 ALL RIGHTS RESERVED

A BUILDING SECTION 1'-8" 20" X 8" CONCRETE FOOTING

4
W/ (3) #4 BARS LONG. & #4 SHEET
4 Scale: 3/8" = 1'-0"
BARS @ 18" O.C. TRANS.
OF 11
CONTINUOUS These plans and specifications are to be
RIDGE VENT considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.

Before construction begins, a building


permit is applied for, or materials are
ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors
or omissions contained within these
12 drawings shall be limited to the redrawing
or redesigning of the plan to address the
situation.
7
The designer grants the client a license to
build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.

These designs and drawings are protected


by the Federal Copyright Laws and may
not be copied, reproduced, modified,
distributed or used in any other way without
the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
owner.

Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
Hoonah, Alaska
4'-0"

9'-1"

you, plans to give you hope and a future."


10'-0"
12 TR. @ 10" 1 1/8" PLYWD. SUBFLOOR GLUED TO JOISTS &
W/ 10d NAILS 6" O.C. EDGE, 12" O.C. FIELD

2'-1 1/8"
PRE-ENGINEERED 24" DEEP 2 X 4 STUDS @ 16" O.C.
FLOOR TRUSSES @ 24" O.C.

4 X 4 BLKG.
1 1/8" PLYWD. RIM JOIST
NAIL 10d @ 6" O.C. EDGE, 12" O.C. FIELD -
19 R. @ 7.06"

NAIL 4 SIDES
11'-2 1/8"

2 X 4 BLKG. NAIL 16d @ 6" O.C. TO PLATES

9'-1"
3'-6 3/8"

1 1/8" PLYWD. SUBFLOOR GLUED TO JOISTS &


W/ 10d NAILS 6" O.C. EDGE, 12" O.C. FIELD 5/8" Ø X 10" ANCHOR BOLTS
48" O.C. & WITHIN 1'-0" OF
11 7/8" BCI/6000 1.8 JOISTS @ 24" O.C.
CORNERS & SILL ENDS UNO.
R-19 SPRAY FOAM INSUL. @ RIM
USE SIMPSON LBP5/8 BEARING SHEET TITLE:
PLATES UNDER BOLT NUT

8" X 48" H. ICF STEM WALL W/


#4 BARS @ 12" O.C. HORIZ.
& #4 @ 18" O.C. VERTICAL
DRAWN BY:
PROTECT FOAM ABOVE GRADE
RICK THIBODEAU

4'-0"
3" CONC. SLAB W/ FIBERMESH 20" X 8" CONCRETE FOOTING 907.789.2897
6 MIL POLY VAPOR RETARDER W/ (3) #4 BARS LONG. & #4
2" R-TECH IV XPS FOAM BD. BARS @ 18" O.C. TRANS. DATE: Feb. 6, 2023
3" WELL COMPACTED SANDY GRAVEL
4" PERF. DRAIN PIPE W/ 6" DRAIN ROCK
8"
ALL AROUND & FILTER FABRIC OVER
DRAIN TO DAYLIGHT C 2023 ALL RIGHTS RESERVED

A BUILDING SECTION 1'-8"

5
SHEET
5 Scale: 3/8" = 1'-0"

OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
P.T. 6 X 10 HF #2 International Residential Code.
engineered components, systems, and
All

HUC610 other manufactured items and equipment


shall be installed according to the
manufacturer's specifications.

Before construction begins, a building


permit is applied for, or materials are
ordered, the building contractor, as
designated by the owner, shall review the
47'-11" plans. The designer's liability due to errors
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the
P.T. 2 X 10 HF #2 situation.

JOISTS 16" O.C. The designer grants the client a license to


build only one structure from the plans, and
LUS28
SHEET VINYL, CUSHIONED SHEET VINYL, CARPET & A A the plans cannot be resold unless by
express written authorization of Rick
PAD, OR CERAMIC TILE FLOOR FINISH: STC 62
MIN. 23/32" STRUCTURAL WOOD 4 36" O.C. 5 Thibodeau dba DesignWorks.
PANEL FLOOR SHEATHING
These designs and drawings are protected
1" GYPSUM FLOOR TOPPING OVER 1/4" 1 3/4" X 11 7/8" LVL RIM X X X by the Federal Copyright Laws and may
SOUND REDUCTION MAT
not be copied, reproduced, modified,
ENGINEERED WOOD LAMINATE distributed or used in any other way without
FLOOR FINISH: STC 61 the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
owner.

Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
BATT INSULATION

RESILIENT CHANNELS

Hoonah, Alaska
1 LAYER 5/8" TYPE 'X' GYP. BD.

PARALLEL CHORD TRUSSES, MAX. 24"


36" X 45"
O.C. MIN. TRUSS DEPTH 12" OPENING
1 HOUR RATING AND STC RATINGS PER GA FC 5012

1 HOUR SOUND RATED TRUSS FLOOR ASSEMBLY


IUS2.37/11.88

11 7/8" BCI/6000 1.8 JOISTS 24" O.C.


INFILL EA. SIDE OF WEB W/ BLKG.

35'-11"

you, plans to give you hope and a future."


BCI BLOCKING

1 HR. INTERIOR WALLS,


TYPICAL
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT
ANGLES TO EACH SIDE OF 2 X 6 WOOD STUDS 16" O.C. WITH 2 1/4"
TYPE S OR W DRYWALL SCREWS 12" O.C. 5 1/2" MINERAL FIBER
INSULATION, NOMINAL 2.5 PCF, FRICTION FIT IN STUD SPACE.

VERTICAL JOINTS STAGGERED 16" O.C., HORIZONTAL JOINTS


STAGGERED 24" O.C., ON OPPOSITE SIDES.

TESTED AT 5,156 LBS. PER STUD OR 100 PERCENT OF DESIGN


LOAD. (LOAD BEARING)

X X

P.T. 2 X 8 LEDGER
P.T. 2 X 6 HF #2 SHEET TITLE:
3'-11"

JOISTS 16" O.C.

GYPSUM WALLBOARD, WOOD STUDS


LUS26
1st F L O O R F R A M I N G
A GA FILE NO. WP 3661 P.T. 4 X 6 HF #2 SCALE: 1/4" = 1'-0"
W1 DRAWN BY:
ONE HOUR RATED BEARING WALL HUC46 MAINE DECK BRACKET @ 6'-0" O.C. OR AS NOTED
6 X RICK THIBODEAU
INSTALL PER MANUFACTURER
1'-7 1/2" 6'-0" 907.789.2897
FLOOR FRAMING TO BE INSTALLED ACCORDING TO
MANUFACTURER'S SPECIFICATIONS, WITH ALL APPROPRIATE DATE: Feb. 6, 2023
BLOCKING, BRACING, & FASTENING.

1 1/8" PLYWOOD SUBFLOOR GLUED & NAILED TO JOISTS. NAIL


C 2023 ALL RIGHTS RESERVED
10d @ 6" O.C. ALL PANEL EDGES; 12" O.C. FIELD
GLUE T & G EDGES

6
SHEET
PROVIDE SQUASH BLKG. IN FLOOR BELOW ALL COLUMNS
OF 11
These plans and specifications are to be
considered only a guide, and they do not

SHEAR WALL SCHEDULE purport to depict every component

IS
O
necessary for the completion of the project.

M
All construction shall conform to the 2012

ET
International Residential Code. All
15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 6" O.C.

RI
engineered components, systems, and

C
other manufactured items and equipment
1 ALONG PANEL EDGES & 12" O.C. FIELD NAILING. 2'-4" 3'-8" 3'-8" 2'-4"

VI
shall be installed according to the

EW
BLOCK ALL PANEL EDGES. manufacturer's specifications.

6 X 10 HF #1 Before construction begins, a building


15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 4" O.C. RIDGE BEAM
permit is applied for, or materials are
ordered, the building contractor, as

2 ALONG PANEL EDGES & 12" O.C. FIELD NAILING. 6 X 10 HF #1 designated by the owner, shall review the

1'-7 1/2"
plans. The designer's liability due to errors
BLOCK ALL PANEL EDGES. EAVE BEAM or omissions contained within these
drawings shall be limited to the redrawing

4 X 6 HF #1 RAFTERS @ 24" O.C.


or redesigning of the plan to address the

2'-0" 2'-1 3/4"


15/32" PLY. OR OSB BOTH SIDES OF WALL W/ 8d situation.

(2) SDWC15450 T.N. EA. END


3 NAILS 4" O.C. ALONG PANEL EDGES & 12" O.C. APHH610 TYP.
6 X 10 HF #1 The designer grants the client a license to
FIELD NAILING. BLOCK ALL PANEL EDGES. RIDGE BEAM
build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.

P.T. 4 X 4 HF #2 COL. These designs and drawings are protected


6 X 10 HF #1 by the Federal Copyright Laws and may

2'-0"
LUS26, TYP. not be copied, reproduced, modified,
P.T. 4 X 6 HF #2 EAVE BEAM distributed or used in any other way without
A the specific written consent of Rick

2'-1 3/4"
Thibodeau dba DesignWorks, the copyright
owner.
4 1 1/8" PLYWD. RIM JOIST
P.T. 2 X 6 HF #2 NAIL 10d @ 6" O.C. EDGE, 12" O.C. FIELD
6'-11"

1'-8 1/4"
P.T. 6 X 6 DF #1 COL. VERT. MSTC66
JOISTS 16" O.C. NAIL 4 SIDES
BELOW, TYP.
1

Wrightson Residence
2 X 4 BLKG. NAIL 16d @ 6" O.C. TO PLATES

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
CC66 OR ECC66 CAP

- Jeremiah 29 : 11
CB66 BASE
DTT1Z VERT. MSTC66
X
6 X 8 HF #2 6 X 8 HF #2 (2) 2 X 6 MIN. IN 6 X 10 DF #1
WALL AT HANGERS DBL. TR. 2 X 8 HF #2
LANDING

TALL STUDS: 2 X 6 BCI VersaStud


X VERT. JOISTS @
MSTC66 16" O.C.

6 X 10 DF #1

Hoonah, Alaska
1.7 2400 @ 12" O.C.
CSHP18
X

14'-4"
X

2 X 6 BEARING WALL 2
X
A35 @ 24" O.C.

PRE-ENGINEERED FLOOR TRUSSES 24" O.C.

you, plans to give you hope and a future."


X
6 X 10 DF #1
P.T. 2 X 12 HF #2 JOISTS 12" O.C.

6 X 6 HF #2
X
P.T. 6 X 12 DF #1

CSHP18
LUS210 HANGERS

2 X 6 BEARING WALL
2 X

1
6 X 10 DF #1

6 X 6 HF #2
X

6 X 6 HF #2
6 X 8 HF #2

X SHEET TITLE:

6 X 10 DF #1 6 X 8 HF #2 6 X 8 HF #2
X
DTT1Z
DRAWN BY:
1 RICK THIBODEAU
VERT. MSTC66 6 X 6 HF #1 COL. IN WALL
A VERT. MSTC66 907.789.2897
FLOOR FRAMING TO BE INSTALLED ACCORDING TO
5
MANUFACTURER'S SPECIFICATIONS, WITH ALL APPROPRIATE DATE: Feb. 6, 2023
2nd F L O O R F R A M I N G BLOCKING, BRACING, & FASTENING.
SCALE: 1/4" = 1'-0"
1 1/8" PLYWOOD SUBFLOOR GLUED & NAILED TO JOISTS. NAIL
X MAINE DECK BRACKET @ 30" O.C. W/ 2 X 10 10d @ 6" O.C. ALL PANEL EDGES; 12" O.C. FIELD C 2023 ALL RIGHTS RESERVED
RIM JOIST BACKING FOR THRU BOLTS GLUE T & G EDGES

7
INSTALL PER MANUFACTURER SHEET
PROVIDE SQUASH BLKG. IN FLOOR BELOW ALL COLUMNS
OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
64'-0" necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
A A shall be installed according to the
manufacturer's specifications.
5 1/2" X 15" 24F-V4 GLULAM , TYP. 4 5 Before construction begins, a building
HGA10KT TRUSS HOLDDOWN & (3) permit is applied for, or materials are
16d TOENAIL EA. TRUSS ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors

OVERHANG
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the

4'-0"
BEAM POCKET W/ LSTA24 TO TOP PL. situation.

6 X 6 HF #1 COL. BELOW W/ BC6 CAP 1 H1 EA. TRUSS TYP. The designer grants the client a license to
build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick

6 X 6 HF #2 6 X 6 HF #2 6 X 10 DF #1 6 X 6 HF #2 Thibodeau dba DesignWorks.

DBL. TR. These designs and drawings are protected


by the Federal Copyright Laws and may
not be copied, reproduced, modified,
distributed or used in any other way without
the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
owner.

Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
PRE-ENGINEERED SCISSOR TRUSSES 24" O.C. PRE-ENGINEERED STANDARD TRUSSES 24" O.C.

- Jeremiah 29 : 11
4 X 6 HF #2

Hoonah, Alaska
W/ LCE4 & (2) 2 X 6 HF #1 1
3
4 X 6 HF #2 HDR. BELOW

OR BTR. KING STUDS

4 X 6 HF #2
GABLE END TRUSS SERVES AS TOP WINDOW HEADER

44'-0"
36'-0"
RIDGE

you, plans to give you hope and a future."


22" X 30"

HATCH
ATTIC
4 X 6 HF #2

A35 OR LTP4 @ 48" O.C. GABLE


END TRUSS TO TOP PLATES
6 X 10 DF #1 6 X 10 DF #1
DBL. TR. 6 X 6 HF #2 DBL. TR.

OVERHANG
1

4'-0"
6 X 6 HF #1 COL.
SHEET TITLE:
(2) 16d BACKSPAN TRUSS TO LOOKOUT
ECCU66 CAP UPRIGHT 2 X 6 LOOKOUTS @ 24" O.C.
CPT66Z BASE W/ SIMPSON H2.5 TIE
(2) 1/2" Ø LAGS, MIN. 5" SHEAR WALL SCHEDULE
PENETRATION INTO BM. BELOW
15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 6" O.C. DRAWN BY:
1 ALONG PANEL EDGES & 12" O.C. FIELD NAILING. RICK THIBODEAU
ROOF FRAMING BLOCK ALL PANEL EDGES. 907.789.2897
SCALE: 1/4" = 1'-0" 15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 4" O.C. DATE: Feb. 6, 2023
2 ALONG PANEL EDGES & 12" O.C. FIELD NAILING.
BLOCK ALL PANEL EDGES.

15/32" PLY. OR OSB BOTH SIDES OF WALL W/ 8d C 2023 ALL RIGHTS RESERVED

3 NAILS 4" O.C. ALONG PANEL EDGES & 12" O.C.

8
SHEET
FIELD NAILING. BLOCK ALL PANEL EDGES.

OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
8 X 8 OR 6 X 6 CEDAR COLUMN 12
shall be installed according to the
manufacturer's specifications.
CAULKING 7
Before construction begins, a building
permit is applied for, or materials are
SLOPED MASONRY CAP ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the
P.T. 1 X 4 FRAMING (2) CSHP18 CONT. 4 situation.
3'-11 1/2"

P.T. 1/2" PLY. SHTG. W/ 2X BLKG. 12


The designer grants the client a license to
build only one structure from the plans, and
2 LAYERS 30# FELT the plans cannot be resold unless by
MANUFACTURED STONE express written authorization of Rick
Thibodeau dba DesignWorks.
VENEER These designs and drawings are protected
by the Federal Copyright Laws and may
not be copied, reproduced, modified,
distributed or used in any other way without
the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
CBSQ88 (OR CBSQ66 FOR 6 X 6 POST) owner.
2'-2"

(2) #3 TIES AT TOP W/ 2" SPACING


(4) #4 VERT.

Wrightson Residence
#3 TIES @ 6" O.C.

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
(4) #4 BARS EA. WAY
8"

14" SQ.
CSHP18
2'-6" SQ.

Hoonah, Alaska
A COLUMN
9 Scale: 1/2" = 1'-0"

FRONT ELEVATION

you, plans to give you hope and a future."


Scale: 3/16" = 1'-0"
APVT6

APVT6

APVA6

APHH610

CSHP18 W/ 2X BLKG.

SHEET TITLE:

DRAWN BY:
RICK THIBODEAU
907.789.2897
DATE: Feb. 6, 2023

B PORCH SECTION C 2023 ALL RIGHTS RESERVED

Scale: 3/8" = 1'-0"

9
9 SHEET
REAR ELEVATION
Scale: 3/16" = 1'-0" OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.

Before construction begins, a building


permit is applied for, or materials are
ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the
situation.

The designer grants the client a license to


build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.

These designs and drawings are protected


CSHP18 by the Federal Copyright Laws and may
not be copied, reproduced, modified,
distributed or used in any other way without
the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
owner.

Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
Hoonah, Alaska
LEFT ELEVATION

you, plans to give you hope and a future."


Scale: 3/16" = 1'-0"

SHEET TITLE:

DRAWN BY:
RICK THIBODEAU
907.789.2897
DATE: Feb. 6, 2023

C 2023 ALL RIGHTS RESERVED

10
SHEET
RIGHT ELEVATION
Scale: 3/16" = 1'-0" OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
10'-2" 3'-8" other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.

Before construction begins, a building


permit is applied for, or materials are
NOTE: ordered, the building contractor, as
END designated by the owner, shall review the

PANEL ENSURE CABINET DIMENSIONS & CONFIGURATIONS plans. The designer's liability due to errors
or omissions contained within these
ALLOW PROPER INSTALLATION & OPERATION OF drawings shall be limited to the redrawing
or redesigning of the plan to address the
APPLIANCES & ADJACENT CABINETS situation.

The designer grants the client a license to


3'-0" 2'-0" 2'-0" 3'-0" build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.

A These designs and drawings are protected


by the Federal Copyright Laws and may

11 not be copied, reproduced, modified,


distributed or used in any other way without
the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
owner.
3'-0" 4'-0" 1'-6" 5'-0" 2'-0" 2'-0" 2'-0" 5'-0" 2'-6" 2'-6"

CORNER

Wrightson Residence
CORNER

"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
3'-6"

Hoonah, Alaska
42" HOOD
OVEN
8'-0"

1'-6"
COOKTOP

OVEN

LAZY LAZY

3'-0"
SUSAN SINK DW SINK
REF SUSAN
BASE BASE

you, plans to give you hope and a future."


3'-0" 4'-0" 2'-6" 3'-0" 3'-0" 3'-0" 2'-0" 3'-0" 2'-0" 2'-0" 2'-0" 2'-0"

KITCHEN CABINETS B C
Scale: 3/8" = 1'-0" 11 11

2'-3" 5'-0" 2'-0" 2'-0" 1'-9" 2'-6" 1'-9" 2'-0" 2'-0" 2'-0" 3'-0"

CORNER CORNER CORNER CORNER

2'-0"
3'-6"

MICRO-HOOD
1'-6"

REF

6'-0"
C 2023 ALL RIGHTS RESERVED

LAZY LAZY LAZY LAZY


3'-0"

RANGE
DW SINK SUSAN SUSAN SUSAN SUSAN
BASE SHEET TITLE:

1'-3" 2'-0" 3'-0" 3'-0" 3'-0" 9" 2'-6" 9" 3'-0" 3'-0" 1'-0" 3'-0"
DRAWN BY:
D E F RICK THIBODEAU
11 11 11 907.789.2897
DATE: Feb. 6, 2023
APARTMENT CABINETS
Scale: 3/8" = 1'-0"

C 2023 ALL RIGHTS RESERVED

11
SHEET

OF 11

You might also like