Professional Documents
Culture Documents
IMPORTANT:
The designer grants the client a license to build only one structure from
the plans, and the plans cannot be resold unless by express written
authorization of Rick Thibodeau dba DesignWorks.
See 2012 International Residential Code Table R302.6.
Door from house to garage to be minimum 1 3/8" solid core wood, 1 3/8 solid or These designs and drawings are protected by the Federal Copyright
honeycomb core steel doors, or 20 minute rated per 2012 International Residential Code Sec.
R302.5.1. Laws and may not be copied, reproduced, modified, distributed or used
in any other way without the specific written consent of Rick Thibodeau
Enclosed accessible space under stairs shall have walls, under stair surface
and any soffits protected on the enclosed side with 1/2" gypsum board. IRC Sec. R302.7. dba DesignWorks, the copyright owner.
Basements, habitable attics and every sleeping room or 4) PERFORM ALL CONSTRUCTION WITH MATERIALS, METHODS, AND WORKMANSHIP
other habitable room equal to or greater than 70 square feet and not used for cooking, eating, ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY.
living room or ther dedicated non-sleeping uses shall have at least one operable emergency 5) PROVIDE ADEQUATE SHORING, BRACING, AND FORMWORK, ETC., AS REQUIRED
escape and rescue opening which shall open directly into a public way, or to a yard or court that FOR THE PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION.
opens to a public way. The units shall be operable from the inside of the room without the use of 6) FOLLOW MANUFACTURERS' RECOMMENDATIONS.
keys, tools, or special knowledge.
7) MAKE ALL PRECAUTION TO INSURE JOBSITE SAFETY.
All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet.
Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet.
The minimum net clear openable height dimension shall be 24 inches. The minimum net clear
openable width dimension shall be 20 inches. When windows are provided as a means of escape Ceiling Insulation: As shown on plans or min. R-49. Sidewalls of skylight wells to have min. wall
or rescue they shall have a finished sill height of not more than 44 inches above the floor. insulation levels of R-19. Skylight areas shall be averaged with ceiling sections to equal overall
U-value of 0.033 or less.
Safety glazing is required in doors, storm doors, railings, within 24" of a door, or when
panes are over 9 square feet and within 18 inches of the floor. (See 2012 IRC Sec. R308.4) Roof areas of enclosed rafter spaces must be ventilated. The minimum required area of the vents
is 1/150 of the area to be ventilated. See 2012 IRC Section 806 for reductions.
Safety glazing is required in any part of a building wall enclosing compartments for hot tubs,
whirlpools, saunas, steam rooms, bathtubs,and showers, where the bottom exposed edge of the Kitchens, Bathrooms and Laundry Rooms. All bathrooms, water closet compartments, laundry rooms with more than one clothes washer Wall Insulation: Rigid foam "outsulation" to comprise min. 43% of total wall R value.
glazing is less than 60 inches above any standing or walking surface. and one clothes dryer and similar rooms shall be provided with a mechanical exhaust system connected directly to the outside with a minimum rated
exhaust capacity of 50 cubic feet per minute and 100 cubic feet per minute for kitchens. Continuous ventilation from intermittent increased capacity Floor Insulation: As shown on plans or min. R-30. Floors over crawl spaces may be uninsulated if
Attic access to be provided with minimum 22" x 30" opening with a 30" min. whole-house or heat-recovery ventilation systems may be used with reduced exhaust capacity as long as an exhaust intake is located in such rooms. crawl space walls are insulated to R-15 at least 24" below grade. Rim joist in all cases insulated to
unobstructed headroom in the attic per R807.1, and crawl space access provided with minimum R-19 min.
18" x 24" opening per R408.4 of the 2012 International Residential Code. To be installed per manufacturer's requirements per UMC 504 and Tables 5A, B & C. Firestops to be
installed at all floor/ceiling chimney penetrations. Any rim joists in crawl spaces must be P.T. wood or equivalent unless covered by min. 2" foam
All wood structural members and their fasteners and connections shall inside or out, or unless the rim joist is at least 12" above grade.
conform to Section R317 of the 2012 International Residential Code. Will be installed with spark/flame minimum 18" above floor and protected from traffic per UPC 1310 and UMC Floor areas that are exposed directly to outside air are to be insulated to R-38.
508.
Smoke alarms shall be interconnected A/C with D/C backup and installed in the Concrete slab on grade floors shall have R-10 perimeter insulation from top of slab to top of
following locations: Minimum clearance space 30" wide by 36" in front by 6'-6" tall access space per NEC 110-16. Panel will not be in clothes closet, footing and then horizontally for a total distance of 4 ft.
1. In each sleeping room. along stair run or in bathrooms per NEC 240-24.
2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. Glazing: U-0.32 Maximum Required.
3. On each additional story of the dwelling. Windows and sliding glass doors are limited to 15% of the exterior wall surface in 1 and 2 family
4. In any habitable room equal to or greater than 70 square feet, and not used for cooking, eating, One on every wall section 2' or longer, and no point along wall can be more than 6' from outlet. dwellings and 25% in townhouses. Glass areas exceeding these limits may be allowed using the
living room or other dedicated, non-sleeping uses. See IRC R314 amended by Title 19.04R313.1. Kitchens: One at every 12" countertop and no more than 48" apart. building envelope requirements of the 2012 International Energy Conservation Code.
One req'd in garage which shall be at least 18" above floor if boiler or spark producing equipment present. Exterior wall area includes all vertical surfaces exposed to the weather, and includes rim joists,
Required on each floor including basement, in halls outside sleeping rooms, and One req'd in each bathroom within 3' of the outside edge of each basin. garage wall areas, and below grade warm wall areas.
inside efficiency apartments. At exterior: one in front of building and one at rear.
All pipes subject to freezing and outside conditioned areas shall be protected from freezing. R-3
All habitable rooms shall have an aggregate glazing area of not less than 8 To comply with NEC Section 210-8. To be provided at kitchens, baths, outside grade level, crawl spaces, all garage minimum insulation is recommended.
percent of the floor area of such rooms. outlets not specifically designated for a particular piece of equipment, and Jacuzzis.
Air Handling Ducts: In areas without a positive heat supply such as attics and crawl spaces shall be
Every dwelling unit shall be provided with heating facilities capable of Required in all habitable rooms per 2008 NEC Sec. 210.12 . insulated to a minimum of R-8.
maintaing a min. room temperature of 68° F at a point 3' above the floor and 2' from exterior
walls in all habitable rooms at the design temperature without involving the combustion of a solid Electrical receptacles every 6' with light, smoke detector, insulation and vapor barrier per NEC 210-52 and Title 19.10.010. If room Vapor Retarders with a perm rating of 1 or less shall be provided on the warm side of wall, ceiling
fuel. is over 70 sq. ft. and served by stairs, natural light and ventilation and egress per 2012 IRC SEC. R303 & R311. and slab insulation.
These plans and specifications are to be
considered only a guide, and they do not
1'-2" 6'-2" 1'-2" 6'-11" purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
A
1'-2"
shall be installed according to the
4'-3" 9 manufacturer's specifications.
9'-1"
situation.
B B
The designer grants the client a license to
build only one structure from the plans, and
36" X 36" X 8" FTG. A A
1'-1 1/4"
3'-7 1/2"
the plans cannot be resold unless by
express written authorization of Rick
W/ (5) #4 BARS EA.
4 5 Thibodeau dba DesignWorks.
6 3/4" WAY, TYP.
These designs and drawings are protected
by the Federal Copyright Laws and may
not be copied, reproduced, modified,
H8 H2 H8 distributed or used in any other way without
D the specific written consent of Rick
Wrightson Residence
VAPOR RETARDER ON CRAWL
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
SPACE FLOOR. EXTEND VAPOR H8
11'-9 1/4"
6'-0"
(3) #4 BARS EA. WAY
Hoonah, Alaska
TOP & BTM., 3" CLR.
2'-0"
C H8
1'-1 1/4" 12'-5 3/4" 14'-0" 10'-2" 5'-10" 3'-11 3/4" 1'-1 1/4"
36'-8"
36'-8"
A.B.'S @36'-8"
H8 H8
D
6 3/4"
3'-10 1/4"
SHEET TITLE:
A A
1
#4 HORIZ. EA. WAY SHEET
SIMPSON PER SCHEDULE.
OF 11
19'-3" 7'-4" 7'-2" These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
21 TR. @ 11" A necessary for the completion of the project.
All construction shall conform to the 2012
10'-7" 2'-9" 2'-11" 7'-9" 3'-6" 7'-4" 2'-4" 10'-10" 9 Before construction begins, a building
permit is applied for, or materials are
ordered, the building contractor, as
10'-0"
A designated by the owner, shall review the
plans. The designer's liability due to errors
4 or omissions contained within these
drawings shall be limited to the redrawing
A
Covered Porch or redesigning of the plan to address the
situation.
5
4'-1"
4'-1"
UP 22 R. @ 7" 8'-0" x 10'-0" The designer grants the client a license to
build only one structure from the plans, and
B B the plans cannot be resold unless by
express written authorization of Rick
Thibodeau dba DesignWorks.
3680
D W
4'-6"
not be copied, reproduced, modified,
5'-0"
(2) 3080
distributed or used in any other way without
UP 19 R. @ 7.06" the specific written consent of Rick
Thibodeau dba DesignWorks, the copyright
F owner.
E
D 11
C 11
11
Bedroom GUARDRAIL
36" REF
12'-0"
Wrightson Residence
Kitchen
13'-4"
4'-2" 4'-6"
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
10'-1" x 7'-1" A 5 TR. @ 10"
DW
2 X 6 STUDS
12 TR. @ 10"
6
Entry
10'-0"
3'-0"
68
9'-4" Mech.
28
7'-10"x
12'-6"
Hoonah, Alaska
7'-4" X 14'-1"
Cabinet
2668
48" Vanity
Linen
2468
Bath
2'-5"
7'-1"
3080
A
Living
48" x 36"
8'-0" x 6'-10"
Shower
B
18'-0" x 21'-2"
4'-8"
36'-0"
Steam Rm.
36'-0"
12'-0"
7'-4"
Shower
M.Bedroom
BENCH
9'-2"
2'-10"
& SOUND INSULATION
3080
Bath
2 X 6 STUDS
12'-4" x 14'-0"
7'-1"
A 8'-0" x 6'-10"
48" Vanity
Cabinet
2668
Linen
4'-5"
9'-8"
7'-5"
2'-5"
8'-2" 2'-5" 2'-5" 4'-0" 1'-6" 9'-0" SHOWER
5'-0" X 10'-3"
4'-0"
3680
3'-0"
2 X 6 STUDS
4'-4"
28
12'-0"
Bedroom
68
Entry
3'-5"
6'-6"
B
14'-8" X 7'-10"
5068
B
(2) 3068
Shelves
4'-4"
3680
3'-6"
W/D
3'-3"
WARDROBE
B B
4'-0"
2
0' 4' 8' and not greater than 2". See IRC Sec. R311.7.7.3 #2 for non-circular handrails. SHEET
3. OPAQUE GLASS
OUTSIDE DIMENSIONS TO FACE OF SHEATHING Required guards on open sides of stairway shall have intermediate rails or ornamental
closures which do not allow the passage of a sphere 4" or more in diameter.
OF 11
These plans and specifications are to be
48'-0" considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
8'-0" 4'-4" 3'-0" 10'-6" 2'-6" 3'-10 3/4" 7'-2 1/4" 6'-11" 2'-9" 4'-0" 2'-9" 2'-0" 2'-6" other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.
A A
Before construction begins, a building
permit is applied for, or materials are
ordered, the building contractor, as
4 5 designated by the owner, shall review the
plans. The designer's liability due to errors
4'-1"
DN 22 R. @ 6.96" A or omissions contained within these
drawings shall be limited to the redrawing
B B H or redesigning of the plan to address the
situation.
4'-6"
Thibodeau dba DesignWorks.
4'-8"
4'-0"
LP GAS Shower
FIREPLACE These designs and drawings are protected
by the Federal Copyright Laws and may
8'-0"
not be copied, reproduced, modified,
distributed or used in any other way without
the specific written consent of Rick
#3
(2) 3080
6'-3" X 13'-8"
Bedroom #3
Wrightson Residence
7'-0"
12 TR. @ 10"
2 X 6 STUDS
A
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
DN 19 R. @ 7.06"
42" VANITY
10'-0"
13'-9" x 13'-8"
Living
19'-4" X 19'-0"
VAULTED CLG.
30" Linen
10'-0"
3080
3080
Cabinet
2'-10"
Hoonah, Alaska
20
80
2'-6"
FLAT CLG.
Covered
5'-0"
B
36'-0"
36'-0"
3080
2'-6"
Deck F E
2'-9"
3080
OVENS
6'-9"
A 11'-1" x 6'-1"
10'-0"
11 6'-3 1/2" 4'-1 1/2"
48" REF
Dining B
11'-0" X 16'-2" 11
36" LINEN
A
5'-0" CABINET
Bedroom #2
96" VANITY
13'-9"
5'-6"
13'-7" x 13'-3"
C
11'-1" x 9'-3" 2680
8'-0"
10'-8" x 15'-8 11
4'-3"
DW 60" TUB
& SHWR.
RAILING PER IRC
D G A
SHEET TITLE:
N
SECOND FLOOR PLAN A
B 11 CASEMENT 2'-4" X 5'-0"
DRAWN BY:
RICK THIBODEAU
1,662 SQ. FT. C 1 DOUBLE CASEMENT 4'-0" X 4'-4" 907.789.2897
OUTSIDE DIMENSIONS TO FACE OF SHEATHING D 1 DOUBLE CASEMENT 4'-8" X 4'-4"
GRAPHIC SCALE
DATE: Feb. 6, 2023
1 FRENCH DOOR (3) 3080
3'-5 11/16"
E
5'-0"
F 1,2
F 1 TRAPEZOID 9'-2" X 5'-0"
G3 1 CASEMENT 2'-4" X 4'-0"
0' 4' 8' C 2023 ALL RIGHTS RESERVED
H 1 FIXED 2'-4" X 5'-0"
3
9'-2" 1. TOP SLOPE 4:12 SHEET
2. MATCH WIDTH TO GLASS DOOR BELOW
3. OPAQUE GLASS
OF 11
CONTINUOUS These plans and specifications are to be
RIDGE VENT considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
METAL ROOFING other manufactured items and equipment
ROOFING UNDERLAYMENT PER shall be installed according to the
manufacturer's specifications.
ROOFING MANUFACTURER
Before construction begins, a building
5/8" PLYWOOD SHTG. W/ CLIPS, permit is applied for, or materials are
STAGGER JOINTS ordered, the building contractor, as
designated by the owner, shall review the
NAIL ROOF W/ 10d @ 6" O.C. PANEL plans. The designer's liability due to errors
PRE-ENGINEERED TRUSSES 24" O.C. These designs and drawings are protected
R-60 BLOWN-IN F.G. INSUL. by the Federal Copyright Laws and may
not be copied, reproduced, modified,
6 MIL POLY V.B distributed or used in any other way without
the specific written consent of Rick
5/8" GYP. BD. Thibodeau dba DesignWorks, the copyright
4 owner.
12
Wrightson Residence
BLOCKING:
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
2 X 4 FRAME W/ PLYWD. OR
PRE-ENGINEERED TRUSS
FRAME, NAIL 4 SIDES 10d @
"REMOTE" WALL CONSTRUCTION :
6" O.C. TOENAIL ALLOWED
2 X 6 HF #2 STUDS @ 16" O.C. (STUDS >9' = HF #1 OR BTR.)
R-19 F.G. BATT CAVITY INSUL.
Hoonah, Alaska
1/2" GYP. BD. @ INTERIOR 4'-0"
15/32" EXTERIOR RATED STRUCTURAL PLYWD. SHTG.
SEE PLAN FOR SHTG. NAILING
ICE & WATER SHIELD INSTALLED OVER SHEATING.
(2) LAYERS 2" XPS FOAM BD.
R-5 PER INCH (R-20) STAGGER JOINTS
9'-1"
COATED SCREWS @ 12" O.C., ANGLED UP 1/2" VERTICAL PER
8'-0"
6" HORIZ. W/ 2.5" EMBEDMENT IN CENTER OF WALL STUD
SIDING PER ELEVATIONS
2'-1 1/8"
PRE-ENGINEERED 24" DEEP
FLOOR TRUSSES @ 24" O.C.
9'-1"
1 1/8" PLYWD. SUBFLOOR GLUED TO JOISTS &
W/ 10d NAILS 6" O.C. EDGE, 12" O.C. FIELD
11 7/8" BCI/6000 1.8 JOISTS @ 24" O.C.
R-19 SPRAY FOAM INSUL. @ RIM
PROTECT FOAM ABOVE GRADE SHEET TITLE:
4'-0"
3" CONC. SLAB W/ FIBERMESH PLATES UNDER BOLT NUT 907.789.2897
6 MIL POLY VAPOR RETARDER
2" R-TECH IV XPS FOAM BD. DATE: Feb. 6, 2023
8" X 48" H. ICF STEM WALL W/
3" WELL COMPACTED SANDY GRAVEL
#4 BARS @ 12" O.C. HORIZ.
& #4 @ 18" O.C. VERTICAL
8"
PROTECT FOAM ABOVE GRADE
C 2023 ALL RIGHTS RESERVED
4
W/ (3) #4 BARS LONG. & #4 SHEET
4 Scale: 3/8" = 1'-0"
BARS @ 18" O.C. TRANS.
OF 11
CONTINUOUS These plans and specifications are to be
RIDGE VENT considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.
Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
Hoonah, Alaska
4'-0"
9'-1"
2'-1 1/8"
PRE-ENGINEERED 24" DEEP 2 X 4 STUDS @ 16" O.C.
FLOOR TRUSSES @ 24" O.C.
4 X 4 BLKG.
1 1/8" PLYWD. RIM JOIST
NAIL 10d @ 6" O.C. EDGE, 12" O.C. FIELD -
19 R. @ 7.06"
NAIL 4 SIDES
11'-2 1/8"
9'-1"
3'-6 3/8"
4'-0"
3" CONC. SLAB W/ FIBERMESH 20" X 8" CONCRETE FOOTING 907.789.2897
6 MIL POLY VAPOR RETARDER W/ (3) #4 BARS LONG. & #4
2" R-TECH IV XPS FOAM BD. BARS @ 18" O.C. TRANS. DATE: Feb. 6, 2023
3" WELL COMPACTED SANDY GRAVEL
4" PERF. DRAIN PIPE W/ 6" DRAIN ROCK
8"
ALL AROUND & FILTER FABRIC OVER
DRAIN TO DAYLIGHT C 2023 ALL RIGHTS RESERVED
5
SHEET
5 Scale: 3/8" = 1'-0"
OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
P.T. 6 X 10 HF #2 International Residential Code.
engineered components, systems, and
All
Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
BATT INSULATION
RESILIENT CHANNELS
Hoonah, Alaska
1 LAYER 5/8" TYPE 'X' GYP. BD.
35'-11"
X X
P.T. 2 X 8 LEDGER
P.T. 2 X 6 HF #2 SHEET TITLE:
3'-11"
6
SHEET
PROVIDE SQUASH BLKG. IN FLOOR BELOW ALL COLUMNS
OF 11
These plans and specifications are to be
considered only a guide, and they do not
IS
O
necessary for the completion of the project.
M
All construction shall conform to the 2012
ET
International Residential Code. All
15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 6" O.C.
RI
engineered components, systems, and
C
other manufactured items and equipment
1 ALONG PANEL EDGES & 12" O.C. FIELD NAILING. 2'-4" 3'-8" 3'-8" 2'-4"
VI
shall be installed according to the
EW
BLOCK ALL PANEL EDGES. manufacturer's specifications.
2 ALONG PANEL EDGES & 12" O.C. FIELD NAILING. 6 X 10 HF #1 designated by the owner, shall review the
1'-7 1/2"
plans. The designer's liability due to errors
BLOCK ALL PANEL EDGES. EAVE BEAM or omissions contained within these
drawings shall be limited to the redrawing
2'-0"
LUS26, TYP. not be copied, reproduced, modified,
P.T. 4 X 6 HF #2 EAVE BEAM distributed or used in any other way without
A the specific written consent of Rick
2'-1 3/4"
Thibodeau dba DesignWorks, the copyright
owner.
4 1 1/8" PLYWD. RIM JOIST
P.T. 2 X 6 HF #2 NAIL 10d @ 6" O.C. EDGE, 12" O.C. FIELD
6'-11"
1'-8 1/4"
P.T. 6 X 6 DF #1 COL. VERT. MSTC66
JOISTS 16" O.C. NAIL 4 SIDES
BELOW, TYP.
1
Wrightson Residence
2 X 4 BLKG. NAIL 16d @ 6" O.C. TO PLATES
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
CC66 OR ECC66 CAP
- Jeremiah 29 : 11
CB66 BASE
DTT1Z VERT. MSTC66
X
6 X 8 HF #2 6 X 8 HF #2 (2) 2 X 6 MIN. IN 6 X 10 DF #1
WALL AT HANGERS DBL. TR. 2 X 8 HF #2
LANDING
6 X 10 DF #1
Hoonah, Alaska
1.7 2400 @ 12" O.C.
CSHP18
X
14'-4"
X
2 X 6 BEARING WALL 2
X
A35 @ 24" O.C.
6 X 6 HF #2
X
P.T. 6 X 12 DF #1
CSHP18
LUS210 HANGERS
2 X 6 BEARING WALL
2 X
1
6 X 10 DF #1
6 X 6 HF #2
X
6 X 6 HF #2
6 X 8 HF #2
X SHEET TITLE:
6 X 10 DF #1 6 X 8 HF #2 6 X 8 HF #2
X
DTT1Z
DRAWN BY:
1 RICK THIBODEAU
VERT. MSTC66 6 X 6 HF #1 COL. IN WALL
A VERT. MSTC66 907.789.2897
FLOOR FRAMING TO BE INSTALLED ACCORDING TO
5
MANUFACTURER'S SPECIFICATIONS, WITH ALL APPROPRIATE DATE: Feb. 6, 2023
2nd F L O O R F R A M I N G BLOCKING, BRACING, & FASTENING.
SCALE: 1/4" = 1'-0"
1 1/8" PLYWOOD SUBFLOOR GLUED & NAILED TO JOISTS. NAIL
X MAINE DECK BRACKET @ 30" O.C. W/ 2 X 10 10d @ 6" O.C. ALL PANEL EDGES; 12" O.C. FIELD C 2023 ALL RIGHTS RESERVED
RIM JOIST BACKING FOR THRU BOLTS GLUE T & G EDGES
7
INSTALL PER MANUFACTURER SHEET
PROVIDE SQUASH BLKG. IN FLOOR BELOW ALL COLUMNS
OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
64'-0" necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
A A shall be installed according to the
manufacturer's specifications.
5 1/2" X 15" 24F-V4 GLULAM , TYP. 4 5 Before construction begins, a building
HGA10KT TRUSS HOLDDOWN & (3) permit is applied for, or materials are
16d TOENAIL EA. TRUSS ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors
OVERHANG
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the
4'-0"
BEAM POCKET W/ LSTA24 TO TOP PL. situation.
6 X 6 HF #1 COL. BELOW W/ BC6 CAP 1 H1 EA. TRUSS TYP. The designer grants the client a license to
build only one structure from the plans, and
the plans cannot be resold unless by
express written authorization of Rick
Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
PRE-ENGINEERED SCISSOR TRUSSES 24" O.C. PRE-ENGINEERED STANDARD TRUSSES 24" O.C.
- Jeremiah 29 : 11
4 X 6 HF #2
Hoonah, Alaska
W/ LCE4 & (2) 2 X 6 HF #1 1
3
4 X 6 HF #2 HDR. BELOW
4 X 6 HF #2
GABLE END TRUSS SERVES AS TOP WINDOW HEADER
44'-0"
36'-0"
RIDGE
HATCH
ATTIC
4 X 6 HF #2
OVERHANG
1
4'-0"
6 X 6 HF #1 COL.
SHEET TITLE:
(2) 16d BACKSPAN TRUSS TO LOOKOUT
ECCU66 CAP UPRIGHT 2 X 6 LOOKOUTS @ 24" O.C.
CPT66Z BASE W/ SIMPSON H2.5 TIE
(2) 1/2" Ø LAGS, MIN. 5" SHEAR WALL SCHEDULE
PENETRATION INTO BM. BELOW
15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 6" O.C. DRAWN BY:
1 ALONG PANEL EDGES & 12" O.C. FIELD NAILING. RICK THIBODEAU
ROOF FRAMING BLOCK ALL PANEL EDGES. 907.789.2897
SCALE: 1/4" = 1'-0" 15/32" PLY. OR OSB ONE SIDE W/ 8d NAILS 4" O.C. DATE: Feb. 6, 2023
2 ALONG PANEL EDGES & 12" O.C. FIELD NAILING.
BLOCK ALL PANEL EDGES.
15/32" PLY. OR OSB BOTH SIDES OF WALL W/ 8d C 2023 ALL RIGHTS RESERVED
8
SHEET
FIELD NAILING. BLOCK ALL PANEL EDGES.
OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
8 X 8 OR 6 X 6 CEDAR COLUMN 12
shall be installed according to the
manufacturer's specifications.
CAULKING 7
Before construction begins, a building
permit is applied for, or materials are
SLOPED MASONRY CAP ordered, the building contractor, as
designated by the owner, shall review the
plans. The designer's liability due to errors
or omissions contained within these
drawings shall be limited to the redrawing
or redesigning of the plan to address the
P.T. 1 X 4 FRAMING (2) CSHP18 CONT. 4 situation.
3'-11 1/2"
Wrightson Residence
#3 TIES @ 6" O.C.
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
(4) #4 BARS EA. WAY
8"
14" SQ.
CSHP18
2'-6" SQ.
Hoonah, Alaska
A COLUMN
9 Scale: 1/2" = 1'-0"
FRONT ELEVATION
APVT6
APVA6
APHH610
CSHP18 W/ 2X BLKG.
SHEET TITLE:
DRAWN BY:
RICK THIBODEAU
907.789.2897
DATE: Feb. 6, 2023
9
9 SHEET
REAR ELEVATION
Scale: 3/16" = 1'-0" OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.
Wrightson Residence
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
Hoonah, Alaska
LEFT ELEVATION
SHEET TITLE:
DRAWN BY:
RICK THIBODEAU
907.789.2897
DATE: Feb. 6, 2023
10
SHEET
RIGHT ELEVATION
Scale: 3/16" = 1'-0" OF 11
These plans and specifications are to be
considered only a guide, and they do not
purport to depict every component
necessary for the completion of the project.
All construction shall conform to the 2012
International Residential Code. All
engineered components, systems, and
10'-2" 3'-8" other manufactured items and equipment
shall be installed according to the
manufacturer's specifications.
PANEL ENSURE CABINET DIMENSIONS & CONFIGURATIONS plans. The designer's liability due to errors
or omissions contained within these
ALLOW PROPER INSTALLATION & OPERATION OF drawings shall be limited to the redrawing
or redesigning of the plan to address the
APPLIANCES & ADJACENT CABINETS situation.
CORNER
Wrightson Residence
CORNER
"For I know the plans I have for you", declares the Lord, "plans to prosper you and not to harm
- Jeremiah 29 : 11
3'-6"
Hoonah, Alaska
42" HOOD
OVEN
8'-0"
1'-6"
COOKTOP
OVEN
LAZY LAZY
3'-0"
SUSAN SINK DW SINK
REF SUSAN
BASE BASE
KITCHEN CABINETS B C
Scale: 3/8" = 1'-0" 11 11
2'-3" 5'-0" 2'-0" 2'-0" 1'-9" 2'-6" 1'-9" 2'-0" 2'-0" 2'-0" 3'-0"
2'-0"
3'-6"
MICRO-HOOD
1'-6"
REF
6'-0"
C 2023 ALL RIGHTS RESERVED
RANGE
DW SINK SUSAN SUSAN SUSAN SUSAN
BASE SHEET TITLE:
1'-3" 2'-0" 3'-0" 3'-0" 3'-0" 9" 2'-6" 9" 3'-0" 3'-0" 1'-0" 3'-0"
DRAWN BY:
D E F RICK THIBODEAU
11 11 11 907.789.2897
DATE: Feb. 6, 2023
APARTMENT CABINETS
Scale: 3/8" = 1'-0"
11
SHEET
OF 11