Professional Documents
Culture Documents
Technical Manual
®
INNOVA M3 New
2. Technical data/
connections
__________________________________________________________________________
Content
1. General .................................................................................................................. 4
2. Water connections................................................................................................ 5
2.1 Cold water................................................................................................................... 6
2.2 Warm water................................................................................................................. 6
2.3 DI-Water...................................................................................................................... 6
2.4 Waste water ................................................................................................................ 7
4. Electric connection............................................................................................... 9
6. Consumables ...................................................................................................... 11
Modifications and services carried out by BHT Hygienetechnik which arise from failings by
the customer, will be invoiced to the customer.
Noise emission:
A-weighted equivalent continuous 58-62 dB (A)
mean sound pressure level
Max. perm. relative air humidity 30% to 95% (non condensing moisture)
If there are panels from the machine up to the ceiling, the panels have to have ventilation
slots. Free cross section 100 cm².
For the connection of automatic cleaning machines to the drinking water supply, all
local/national regulations must be followed (for example in Germany DIN 1988 and “DVGW”
regulations and specifications must be followed).
Install electric connections in accordance with the IEC regulations and local/ national (in
Germany VDE) regulations.
2. Water connections
Shut off valve:
2.3 DI-Water
Ball valve 3/4" to the machine with double nipple with
Connection
¾ " external thread
Water quality Max. 10 µS/cm
Flow pressure 2 - 5 bar
Consumption per charge Approx. 18 to 20 l
* Values consumed are subject to the structural conditions. Deviations up to 20% is possible.
Water connections
Water temperature
Up to 80°C/ only short time 1 minute.
(acc. to wash program)
Capacity 30 l/min
pH value 5–9
Machine side discharge 19 mm internal diameter, 1.2 m long.
Place of installation Flush with the finished wall
Washing machine siphon at customer site mounted
Siphon slightly inside or above the surface of the finished
wall.
4. Electric connection
Power supply cable to the BHT INNOVA® M3 New has to be connected to the
terminal box of the machine and grounded properly in accordance with the valid IEC
guidelines. Each machine requires its particular rated fuses and particular supply
cable. Earth leakage circuit breaker, according to IEC guidelines and local/national
(in Germany VDE) regulations.
Electrical rating:
35 A
Fuse 20 A
Connected load 11 kW 11 kW
Tank heating 7 kW 7 kW
Boiler (option) 9 kW 9 kW
At site in cabinet
Place of container Max. 650 mm above the finished floor
Max. distance 10m
The ends of the hoses are colour marked with the kind of chemical that shall be used
with it (e. g. cleaner = white, disinfector = blue).
If several machines are supplied from only one container for each detergent, a
dosage control is necessary. The connection to a central dosing control is also
possible. For details please contact the manufacturer.
6. Consumables
- Cleaning agent.
- Disinfectant.