SI9416> alt

180404-19:24:14 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335

Connecting to 10.57.242.241:56834 (CorbaSecurity=OFF, corba_class=2, java=1.7.0_51,


jacoms=R93D03, jacorb=R89C01)
Trying file=/var/opt/ericsson/amos/moshell_logfiles/ricc2/logs_moshell/tempfiles/
20180404-192142_20291/ior20291
Resolving the alarm service in OMS...
Simple Alarm Client initialized...
Starting to retrieve active alarms
Nr of active alarms are: 3
===================================================================================
=================================
Date & Time (Local) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2018-04-04 17:50:35 C License Key File Fault Licensing=1 (No license
key file installed. IntegrationUnlock=ACTIVATED, 21 days remaining)
2018-04-04 17:50:35 m Password File Fault Security=1
(configuration_or_customizing_error)
2018-04-04 17:52:50 C External Alarm HwUnit=SUP-1,AlarmPort=5
(FALHA TROCADOR DE CALOR)
>>> Total: 3 Alarms (2 Critical, 0 Major)
========================================================
SENHA NÃO FOI TROCADA POR ESSE COMANDO
======================================================
SI9416> passwd;aeiSP#11;aeiSP#11

180404-19:25:17 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335


The current password is incorrect!
Syntax: passwd ; <current password> ; <new password>
SI9416> passwd;rbs;aeiSP#11

========================================================
SENHA NÃO FOI TROCADA POR ESSE COMANDO
======================================================

SI9416> passwd;rbs;aeiSP#11

180404-19:26:01 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335


The current password is incorrect!
Syntax: passwd ; <current password> ; <new password>

==============================================================================
FORMA CORRETA
===============================================================================
SI9416> echo $password

180404-19:32:07 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335


$ echo uv exclude_deprecated=1
uv exclude_deprecated=1
$

SI9416> passwd ; uv exclude_deprecated=1 ; aeiSP#11

180404-19:33:49 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335


$ passwd
aeiSP#11
aeiSP#11
Enter new password:
Re-enter new password:

SI9416> lt all

180404-19:33:55 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335


Connected to 10.57.242.241
(SubNetwork=ONRM_ROOT_MO_R,SubNetwork=ACAS04,MeContext=SI9416,ManagedElement=1)
Last MO: 1419. Loaded 1419 MOs. Total: 1420 MOs.

SI9416> alt

180404-19:34:02 10.57.242.241 18.0b RBS_NODE_MODEL_U_4_591 stopfile=/tmp/20335

Connecting to 10.57.242.241:56834 (CorbaSecurity=OFF, corba_class=2, java=1.7.0_51,


jacoms=R93D03, jacorb=R89C01)
Trying file=/var/opt/ericsson/amos/moshell_logfiles/ricc2/logs_moshell/tempfiles/
20180404-192142_20291/ior20291
Resolving the alarm service in OMS...
Simple Alarm Client initialized...
Starting to retrieve active alarms
Nr of active alarms are: 2
===================================================================================
=================================
Date & Time (Local) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2018-04-04 17:50:35 C License Key File Fault Licensing=1 (No license
key file installed. IntegrationUnlock=ACTIVATED, 21 days remaining)
2018-04-04 17:52:50 C External Alarm HwUnit=SUP-1,AlarmPort=5
(FALHA TROCADOR DE CALOR)
>>> Total: 2 Alarms (2 Critical, 0 Major)

===================================================================================
==========================================================