############ alarme existente no GSM ##############

RXCDP:MO=RXOTG-36;

Alarme: MCTR BANDWIDTH SETTINGS MAY BE INSUFFICIENT


Este alarme aparece porque o limite de frequencia est� fora da faixa no setor.
Para retirar esse alarme, basta seguir os passos abaixo:

##verificando frequencia m�nima e m�xima do setor###


RLCFP:CELL=1EMB061;
RLCFP:CELL=1EMB062;
RLCFP:CELL=1EMB063;

###BLOQUEAR###
RXBLI:MO=RXOTG-36,SUBORD,FORCE;
RXESE:MO=RXOTG-36,SUBORD;

##SETOR 1##
RXMOC:MO=RXOMCTR-36-0,MINFREQ=587,MAXFREQ=629;
RXMOC:MO=RXOMCTR-36-1,MINFREQ=587,MAXFREQ=629;
RXMOC:MO=RXOMCTR-36-2,MINFREQ=587,MAXFREQ=629;
RXMOC:MO=RXOMCTR-36-3,MINFREQ=587,MAXFREQ=629;
##SETOR 2##
RXMOC:MO=RXOMCTR-36-4,MINFREQ=589,MAXFREQ=636;
RXMOC:MO=RXOMCTR-36-5,MINFREQ=589,MAXFREQ=636;
RXMOC:MO=RXOMCTR-36-6,MINFREQ=589,MAXFREQ=636;
RXMOC:MO=RXOMCTR-36-7,MINFREQ=589,MAXFREQ=636;
##SETOR 3##
RXMOC:MO=RXOMCTR-36-8,MINFREQ=594,MAXFREQ=632;
RXMOC:MO=RXOMCTR-36-9,MINFREQ=594,MAXFREQ=632;
RXMOC:MO=RXOMCTR-36-10,MINFREQ=594,MAXFREQ=632;
RXMOC:MO=RXOMCTR-36-11,MINFREQ=594,MAXFREQ=632;

###DESBLOQUEAR###
RXESI:MO=RXOTG-36,SUBORD;
RXBLE:MO=RXOTG-36,SUBORD;

!VERIFICAR ALARMES!
RXMFP:MO=RXOCF-36,SUBORD,FAULTY;
RXASP:MO=RXOTG-36;
RXCDP:MO=RXOTG-36;

!VERIFICAR SE EST� OPER E ENA!


RXMSP:MO=RXOTG-36,SUBORD;