MEMBER REPORT PASSED

Level, Wall: Header 4.3m


2 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL

All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Wall
Member Type : Header
Member Reaction (kN) 47.2 @ 188mm 48.63 (76mm) Passed (97%) 1.00 1.25 D + 1.5 S + 1.0 L (Adj Spans)
Building Use : Residential
Shear (kN) 35.65 @ 582mm 69.02 Passed (52%) 1.00 1.25 D + 1.5 S + 1.0 L (Adj Spans)
Building Code : NBCC 2015
Moment (kN-m) 47.31 @ 2376mm 47.07 Passed (100%) 1.00 1.25 D + 1.5 S + 1.0 L (Alt Spans) Provincial Code : OBC 2012
Live Load Defl. (mm) 11.870 @ 2376mm 12.156 Passed (L/369) -- 1.0 D + 1.0 S + 0.4 W (Alt Spans) Design Methodology : LSD
Total Load Defl. (mm) 17.185 @ 2376mm 18.233 Passed (L/255) -- 1.0 D + 1.0 S + 0.4 W (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• A 14% decrease in the moment capacity has been added to account for lateral stability.
• A bearing length of 89mm has been used for Point Load Near Support Check.
• The importance category considered for this design is normal.
• The moment, shear, and member reaction values are based on factored loads (strength). Support reactions and deflections are based on unfactored loads (service).

Bearing Length Loads to Supports (kN)

Supports Total Available Required Dead Floor Live Snow Wind Accessories

1 - Trimmer - SPF 76mm 76mm 74mm 11.12 4.76 19.02 19.04 None
2 - Trimmer - SPF 76mm 76mm 74mm 11.12 4.76 19.02 19.04 None

Lateral Bracing Bracing Intervals Comments

Top Edge (Lu) 1200mm o/c


Bottom Edge (Lu) 1200mm o/c

Vertical Loads Location Tributary Width Dead Floor Live Snow Wind Comments

0 - Self Weight (kN/m) 0mm to 4752mm N/A 0.21 -- -- --


1 - Uniform (kPa) 0mm to 4752mm 4000mm 1.12 0.5 2.0 2.0

Shear (kN) Moment (kN-m) Deflection (mm)

Location Analysis Actual Allowed LDF Actual Allowed LDF Live Load Total Comments

1 - 0mm 0.0 69.02 1.00 0.00 35.56 0.65 -1.477 -2.134


2 - 1000mm 27.35 69.02 1.00 28.51 54.71 1.00 6.658 9.639
3 - 2000mm 7.5 69.02 1.00 45.90 54.71 1.00 11.457 16.588
4 - 2400mm -0.51 69.02 1.00 47.30 54.71 1.00 11.868 17.183
5 - 2800mm -8.45 69.02 1.00 45.52 54.71 1.00 11.346 16.427
6 - 3200mm -16.39 69.02 1.00 40.57 54.71 1.00 9.923 14.366
7 - 3600mm -24.33 69.02 1.00 32.44 54.71 1.00 7.690 11.133
8 - 4000mm -32.27 69.02 1.00 21.13 54.71 1.00 4.796 6.942
9 - 4400mm -40.21 69.02 1.00 6.65 54.71 1.00 1.446 2.093
10 - 4800mm N/A N/A N/A N/A N/A N/A N/A N/A

ForteWEB Software Operator Job Notes


4/10/2023 5:28:31 PM UTC
Nevin Koshy
Jablonsky, Ast & Partners ForteWEB v3.5, Engine: V8.2.5.1, Data: V8.1.3.6
(416) 824-7480
nkoshy@astint.on.ca File Name: Wall opening
Page 1 / 2
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator

ForteWEB Software Operator Job Notes


4/10/2023 5:28:31 PM UTC
Nevin Koshy
Jablonsky, Ast & Partners ForteWEB v3.5, Engine: V8.2.5.1, Data: V8.1.3.6
(416) 824-7480
nkoshy@astint.on.ca File Name: Wall opening
Page 2 / 2

You might also like