You are on page 1of 64

I Architectural Detailing

2015 EDITION
I Architectural Detailing
Architectural Detailing

I1 Introduction
I2 Standard Details
I3 Standard Architectural Specifications
I

I4 BIM Software

This chapter of the AFS Designer must be read in conjunction with all chapters of the AFS Designer.
Important legal statements on inside back cover.

DESIGNER 2015
I Architectural
ArchitecturalDetailing
Detailing

Architectural Detailing
Architectural Detailing
Disclaimer: This section of the AFS Designer is intended only by AFS to represent good building practice in achieving suitable architectural detailing of AFS
LOGICWALL®. This section is not intended in any way by AFS to represent all relevant information required on a project. It is the responsibility of those using
AFS LOGICWALL®, including but not limited to builders, designers, consultants and engineers, to ensure that AFS LOGICWALL® is suitable for use on a project in
relation to architectural design. All diagram, plans and illustrations used in this section including any reinforcement shown are included for indicative and
diagrammatic purposes only. It is the responsibility of those using AFS LOGICWALL® to ensure that reference is made to the structural engineer’s details for all
diagrammatic and reinforcement requirements.

I1 Introduction

I
I
The architectural detailing and design of AFS LOGICWALL® Whilst examples of previously successful details are
for building projects requires the services of professional included throughout this chapter it does not replace the
consultants, such as architects and engineers. This chapter services of professional consultants nor is to be relied upon
has been prepared to assist consultants in project as a complete library of details as site conditions can vary
documentation and outlines a range of typical details. from project to project.

I2 Standard Details
Note:
1 - Except as noted on the following details,
details, materials
materialsand
andwork
workrequired
requiredare
arenot
notprovided
providedby
byAFS
AFSororthe
theLOGICWALL
®
installation contractor.
LOGICWALL installation
22 -- All
All details
detailsininthis
thischapter
chapterarearediagrammatic
diagrammatic onlyonly
andand
not not drawn
drawn to scale.
to scale.
Page
I2.1 Slab Junctions .......................................................................................................................... Page
I 2.0 Recommended Finishes Schedule 145
I 2.1.1 Horizontal
I 2.1 Slab Junctions Expressed Joint With Rebate in Slab Edge ....................................................................................143
II 2.1.1
2.1.2 Horizontal
Horizontal Expressed
Expressed Joint
Joint With
With Flat Platein Slab
Rebate Slab Edge
Edge.....................................................................................144
....................................................................................146
II 2.1.2
2.1.3 Horizontal Joint
Horizontal Expressed Joint With
With Cover PlateFlat PlateEdge
On Slab Slab ............................................................................................145
Edge.....................................................................................147
II 2.1.3
2.1.4 Horizontal 20mm
Horizontal Joint With Cover Plate
Expressed On Slab Edge.............................................................................................148
Joint................................................................................................................146
I 2.1.4 Horizontal 20mm Expressed Joint................................................................................................................149
I 2.1.5 Cavity Wall Detail – Flat Slab .......................................................................................................................147
I 2.1.5 Cavity Wall Detail – Flat Slab.......................................................................................................................150
I 2.1.6 Edgeform at Floor/Slab Junction..................................................................................................................148
I 2.1.6 Edgeform at Floor/Slab Junction..................................................................................................................151
II 2.1.7
2.1.7 External Wall/Slab
Slab Junction HOBJunction For Typical Raft Slab (domestic application) .........................................................149
Detail ...........................................................................................................................152
II 2.1.8
2.1.8 Retaining
EdgeformWall / Basement
At Floor/Slab Wall Slab
Junction. Junction ..............................................................................................150
.................................................................................................................153
II 2.1.9
2.1.9 Retaining
External Wall/Slab JunctionWall
Wall / Basement For Footing
Typical Raft Slab...........................................................................................151
Junction .........................................................................................154
II 2.1.10
2.1.10 Wall
Retaining Wall / Basement
Slab Junction, Wall Slab
Beam System Junction.
Parallel ..............................................................................................155
To AFS LOGICWALL ......................................................................152
I 2.1.11 Retaining Wall / Basement Wall Footing Junction .........................................................................................155
I 2.1.11 Wall Slab Junction, Beam System Perpendicular to AFS LOGICWALL .............................................................153
I 2.1.12 Wall Slab Junction, Beam System Parallel To AFS LOGICWALL®.....................................................................157
I 2.1.12 Wall Slab Junction, Beam System Perpendicular to AFS LOGICWALL Façade Wall ..........................................154
I 2.1.13 Wall Slab Junction, Beam System Perpendicular to AFS LOGICWALL®...........................................................158
II 2.1.14
2.1.13 Permanent Formwork,
Wall Slab Junction, Junction
Beam SystemTo Perpendicular
AFS LOGICWALL Façade
to AFS Wall (i.e.®Bondek
LOGICWALL FaçadeorWall. similar metal floor system) ....155
........................................159
II 2.1.15
2.1.14 Permanent
Permanent Formwork, Junction
Junction To
To AFS
Internal AFS LOGICWALL
LOGICWALL ® (i.e. Bondek
Façade Wall or similar
(i.e. Bondek metal
or similar floorfloor
metal system) ...........156
system).......160
II 2.1.16
2.1.15 Step
Permanent Formwork,
Floor/Stair LandingJunction To Internal AFS LOGICWALL® (i.e. Bondek or similar metal floor system)..........161
Detail ....................................................................................................................157
II 2.1.17
2.1.16 AFS
StepLOGICWALL
Floor/Stair Landing Detail....................................................................................................................162
Wall Connections To Stair Mid Landing ...............................................................................158
I 2.1.18 AFS LOGICWALL Wall Connections To Stair Mid Landing.............................................................................163
®
I 2.2 Post-tensioned Slabs
I 2.2 Post-tensioned Slabs
I 2.2.1 Post-tensioned Slab Detail ..........................................................................................................................159
I 2.2.1 Post-tensioned Slab Detail..........................................................................................................................164
I 2.2.2
I 2.2.2 Post-tensioned
Post-tensioned Slab
Slab To
To AFS
AFS LOGICWALL
LOGICWALL®(Internal)(Internal)Wall .................................................................................160
Wall...............................................................................165
I 2.3
2.3Corners
Cornersand
and
TeeTee Junctions
Junctions
II 2.3.1
2.3.1 AFS LOGICWALL
AFS LOGICWALL®Wall
Wall90°
90°Prefabricated
PrefabricatedCorner
Corner- Single
- SingleReinforcement
ReinforcementCarriers
Carriers..........................................166
............................................161
II 2.3.2
2.3.2 AFS LOGICWALL
AFS LOGICWALL Wall
®
Wall90°
90°Prefabricated
PrefabricatedCorner
Corner– –Double
DoubleReinforcement
ReinforcementCarriers
Carriers- with
- with"L"“L”bars
bars..................167
...................162

143
141
WALLING SOLUTIONS DESIGNER 2012
DESIGNER 2015
Architectural Detailing

I 2.3.3 AFS LOGICWALL® Wall 90º Prefabricated Corner - Double Reinforcement Carriers - with “U” bars...................168
I 2.3.4 Squint Corner Detail for 135° Corners or Angle............................................................................................169
I 2.3.5 AFS LOGICWALL® Wall Tee Junction............................................................................................................170
I 2.4 Panel Joints
I 2.4.1 Movement Joint..........................................................................................................................................171
I

I 2.4.2 Fibre Cement Sheet Surface Joint................................................................................................................172


I 2.4.3 Double Height Wall – Horizontal Joint...........................................................................................................173
I 2.5 Boundary Walls
I 2.5.1 AFS LOGICWALL® Wall Adjacent to Existing Structure Flashing Detail............................................................174
I 2.5.2 Unfinished Boundary Wall Flashing Detail.....................................................................................................175
I 2.5.3 Safety Balustrade / Boundary Wall Detail......................................................................................................176
I 2.6 Junctions with Other Wall Types
I 2.6.1 AFS LOGICWALL® Wall/ Plasterboard Wall Junction .....................................................................................177
I 2.6.2 AFS LOGICWALL® Wall/ Double Brick Junction.............................................................................................178
I 2.6.3 AFS LOGICWALL® Wall/ Brick Veneer Junction.............................................................................................179
I 2.6.4 Brick Veneer Facade over AFS LOGICWALL..................................................................................................180
I 2.7 Doors, Windows & Openings
I 2.7.1 Fire Door Frames - Option 1........................................................................................................................181
I 2.7.2 Fire Door Frames - Option 2........................................................................................................................182
I 2.7.3 Non-Fire Rated Door Frames.......................................................................................................................183
I 2.7.4 Commercial Window Section.......................................................................................................................184
I 2.7.5 Rebate Window..........................................................................................................................................185
I 2.7.6 Typical Opening In Wall...............................................................................................................................186
I 2.8 Cast In Elements
I 2.8.1 Cast In Lift Rails..........................................................................................................................................187
I 2.8.2 Services.....................................................................................................................................................188
I 2.9 Balcony Walls
I 2.9.1 Balustrade Wall...........................................................................................................................................189
I 2.9.2 Balcony Dividing Wall..................................................................................................................................190
I 2.9.3 Balcony Wall Detail Without HOB..................................................................................................................191
I 2.9.4 Balcony Wall Detail With HOB......................................................................................................................192
I 2.10 Timber Component Connections
I 2.10.1 AFS LOGICWALL® Wall/ Timber Floor Junction..............................................................................................193
I 2.10.2 AFS LOGICWALL® Wall/ Timber Top Plate Connection...................................................................................194
I 2.11 Blade Walls
I 2.11.1 Blade Wall Detail.........................................................................................................................................195
I 2.12 Acoustic & Thermal Details
I 2.12.1 External Wall with Foil Board........................................................................................................................196
I 2.12.2 Separating Wall – Wet Area/Living Area or Wet to Wet Area...........................................................................197

144
DESIGNER 2015
Architectural Detailing
I2.0 Recommended Finishes Schedule

Amend to suit Project

EXTERNAL

I
LOGICWALL®
Location System Panel Joints Finishing System(1)
Requirements
Marine,
Refer AS3600 External Flush Set Refer Façade Consultant
Coastal(2)

Dulux AcraTex High Build System, Duspec


AC1202 Issue 4.
F’c 40 Mpa minimum
Dulux Material Warranty (Project Specific)
Central reinforcement
Near Coastal only 10year applicable on approved systems
External Flush Set incorporating (2) final Weatherproofing
(1 to 50 km)
All external fitting, AcraShield or AcraSkin Topcoat.
fixtures, render strips to
be UPVC or Stainless. 10 year applicableon approved systems
incorporating (1) final Weatherproofing
AcraShield or AcraSkin Topcoat.

Standard AFS DULUX Acratex - AFS LOGICWALL W&W Interior


Inland Tropical External Flush Set
LOGICWALL® Finish System. Issue 1.1

INTERNAL

LOGICWALL®
Location System Panel Joints Finishing System(1)
Requirements
Standard AFS DULUX Acratex - AFS LOGICWALL W&W Interior
DULUX Interior Internal Flush Set
LOGICWALL® Finish System. Issue 1.1

System 1 -
Standard AFS
Joint Setting Internal Flush Set not used
LOGICWALL®
Only

System 2 - Method 1 -Spray applied thin Gyprock Total Joint


Joint Setting Standard AFS Cement
Internal Flush Set
and Skim LOGICWALL® Method 2 - Roller applied thin Gyprock Total
Coating Joint Cement

Method 1 - Direct Stick Plasterboard finish to


System 3 - Standard AFS Architectural Specification
Internal Flush Set
Over Sheeting LOGICWALL® Method 2 - Batten and sheet finish to
Architectural Specification

(1) Refer AFS Data Manual for Details and specifications for finishes.
(2) All external fixtures, fixings, moldings etc in Coastal or Marine Environments AS2312 Classification D or
greater to be UPVC or Stainless.

Note: All external steel fixtures, fixings, mouldings to be galvanized.

145
DESIGNER 2015
Detail #1

Architectural Detailing
Architectural Detailing

Horizontal Express Joint with


I2.1 Slab Junction Details
Rebate in Slab Edge
I 2.1.1 Horizontal Expressed Joint With Rebate in Slab Edge

I
I

Vertical and horizontal


reinforcement to engineer’s
EXTERNAL INTERNAL
details
AFS LOGICWALL
1. The horizontal Two continuous beads of
joint is recessed sealant under floor track on
on site all external walls and
internal separation walls
2. Joint is taped and by AFS LOGICWALL installation contractor
set with external
coating system by Paintable
waterproofing membrane
external coating
applicator. Refer to
Set down in slab
detail I 2.1.4
as detailed by structural engineer
3. The 20mm PVC
render mould section
is applied to the joint Concrete floor
(by external coating 20mm slab to engineers
applicator). Refer to details
detail I 2.1.4
4. Trowel on acrylic
render and waterproof Steel clinching angle and AFS
membrane is applied to LOGICWALL frame within
the entire wall surface slab zone. (Can be removed
area (by external onsite where required).
coating applicator)
EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
(REFER RECOMMENDED
FINISHES SCHEDULE).
Wall to slab cold joint

Draft v3 20/9/11

146 143
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #2
Architectural Detailing

Architectural Detailing
Horizontal Express Joint with
I 2.1.2 Horizontal Expressed Flat Plate
Joint With Flat Slab Edge
Plate Slab Edge
I

I
EXTERNAL INTERNAL

Vertical and horizontal


reinforcement to engineer’s
1. The horizontal details
joint is recessed
on site AFS LOGICWALL
2. Joint is taped and Two continuous beads of
set with external sealant under floor track on
water proofing all external walls and
membrane by external internal separation walls
coating applicator by AFS LOGICWALL installation contractor
Refer to detail I2.1.4
Paintable
waterproofing membrane
3. The 20mm PVC
render mould section
is applied to the joint Concrete floor
(by external coating slab to engineer’s
applicator) details
Refer to detail I2.1.4

4. External Finishes
to project specification Steel clinching angle and AFS
(Refer recommended LOGICWALL frame within
finishes schedule) slab zone. (Can be removed
on site where required).

Wall to slab cold joint

Draft v3 20/9/11

144 147
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #3

Architectural Detailing
Architectural Detailing

Horizontal Joint with


I 2.1.3 Cover
Horizontal Joint With CoverPlate
Plate Onon
SlabSlab
Edge Edge

I
I

Vertical and horizontal


reinforcement to engineer’s
details
EXTERNAL INTERNAL
AFS LOGICWALL

Sealant
Two continuous beads of
sealant under floor track on
all external walls and
internal separation walls
9mm CFC cover by AFS LOGICWALL installation contractor
strip or equivalent

Concrete floor slab to


engineer’s details
Flashing

Steel clinching angle and AFS


LOGICWALL frame within
slab zone (Can be removed
onsite where required).

Concrete wall to
slab cold joint

Internal applied
finishes

EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
(REFER RECOMMENDED
FINISHES SCHEDULE).

Draft v3 20/9/11

148 145
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #4
Architectural Detailing

Architectural Detailing
Horizontal 20mm Express Joint
I 2.1.4 Horizontal 20mm Expressed Joint

EXTERNAL
I

I
AFS LOGICWALL

Horizontal joint is
recessed on site

Setting and waterproofing


of joint to take place prior
to application of the 20mm
PVC render mould

20mm

The 20mm PVC


render mould section
is applied to the joint
(by external coating
applicator, see insert
below)
Trowel on acrylic render
and waterproof
EXTERNAL FINISHES TO
membrane
PROJECT’S is applied to
SPECIFICATION
the entire
(REFER wall surface
RECOMMENDED
FINISHES SCHEDULE).
area (by external
coating applicator)

2mm
20mm PVC render mould

25mm

70mm 20mm

25mm

Draft v3 20/9/11

146 149
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #43

Architectural Detailing
Architectural Detailing

Cavity Wall Detail Flat Slab


I 2.1.5 Cavity Wall Detail – Flat Slab

I
I

EXTERNAL INTERNAL

Vertical and
horizontal
reinforcement to
engineer’s details
Plasterboard
sheeting

AFS LOGICWALL
Two continuous beads of Preformed
sealant under floor track on hob system
all external walls and
internal separation walls
by AFS LOGICWALL membraned
installation contractor cavity
Paintable waterproofing
membrane

Concrete floor slab to engineering


details
Flashing

Steer clinching angle and AFS LOGICWALL


frame within slab zone
9mm CFC cover
(Can be removed onsite
strip or equivalent
where required).

Sealant

Concrete wall to
slab cold joint

External finishes to
project’s specification
(Refer Recommended
Finishes Schedule).

Draft v3 20/9/11

150 147
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #5
Architectural Detailing

Architectural Detailing
I 2.1.6 AFS LOGICWALL®AFS Edgeform
Edgeform atJunction
at Floor/Slab Foor/Slab
Junction
I

I
Vertical and horizontal
External sheeting shop reinforcement to engineer’s
drawn to top of slab details
level or slab rebate level
(can be trimmed to site
tolerances as required).

Concrete floor slab


to engingeer’s details
Maximum unsupported
edgeform height is
200mm. For edgeform
over 200mm, extra form Steel clinching angle and
work support is required AFS LOGICWALL frame within slab zone
(Can be removed on site
where required).

Concrete wall to Internal sheeting shop drawn to soffit level


slab cold joint (can be trimmed to site tolerances as required).

AFS LOGICWALL

Internal applied
finishes

148 151
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing

I 2.1.7 Slab Junction HOB Detail


I

EXTERNAL INTERNAL

152
DESIGNER 2015
Architectural Detailing
I 2.1.8 Edgeform At Floor/Slab Junction

I
EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
(REFER RECOMMENDED
FINISHES SCHEDULE).

EXTERNAL INTERNAL

153
DESIGNER 2015
Architectural Detailing
Architectural Detailing

Detail #6
I 2.1.9 External Wall/Slab Junction For Typical Raft Slab

I
External wall/Slab Junction for
I

Typical Raft Slab (domestic application)


EXTERNAL INTERNAL

External finishes to Vertical and horizontal


project’s specification reinforcement to engineers
(Refer Recommended details,
Finishes Schedule).

AFS LOGICWALL

Two continuous beads of Paintable waterproofing


sealant under floor track on membrane
all external walls and Void grout filled,
internal separation walls
by AFS LOGICWALL installation Set down in slab
contractor
as detailed by structural engineer
AFS LOGICWALL
punched floor track

Flashing

This horizontal joint Concrete floor slab to engineer’s details


can be treated using
the banding strip or
the membrane detail,
as outlined in earlier
details - dependent
on the natural ground
level

Edge beam to Soil


engineer’s details

154 149
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Draft v3 20/9/11
Option A
Architectural

Detail
DetailDetail
#7#7 #7
I 2.1.10 AFS LOGICWALL® Retaining Wall / Basement Wall Slab Junction

Detail #7
Architectural Detailing
Architectural DetailingI

Architectural Detailing
Architectural Detailing
AFS
AFS
Retaining
Retaining
Wall
Wall
Slab
Slab
Junction
Junction
Architectural Detailing

AFS
Wall Retaining
AFS Retaining Option
Slab
A Junction
Option WalltoSlab
AWall thickness project Junction
Option A Option A
specifications

I 2.1.10
I 2.1.10
AFS AFS
LOGICWALL
LOGICWALL
® Retaining
® Retaining
Wall Wall
/ Basement
/ Basement
Wall Wall
SlabSlab
Junction
Junction
I 2.1.10 AFS LOGICWALL I 2.1.10 AFS LOGICWALL
® Retaining ® Retaining WallAFS
Wall / Basement / Basement
LOGICWALL Wall Slab Junction
Wall Slab Junction
I
I

Vertical and horizontal

I
I
I

reinforcement to
engineer’s details
Maximum depth of fill Wall thickness
Wall thickness
to project
to project
to engineers detail Backfilled to Wall specifications
specifications
thickness to project Wall thickness to project
engineers Typical waterproofing specifications
specifications
requirements membrane applied to
AFS LOGICWALL
AFS LOGICWALL
wall, overlaid with
“coreflute” as approved AFS LOGICWALL
AFS LOGICWALL

Vertical
Vertical
Starter and horizontal
bars and horizontal
600mm min.
reinforcement
reinforcement
intoand
Vertical paneltoto project
wallhorizontal to Vertical and horizontal
engineer’s
engineer’s
engineers
reinforcement detailsdetails reinforcement to
todetails
engineer’s details engineer’s details
Backfilled
Backfilled
to to
engineers
engineers Flashing at slab level
Backfilled to Backfilled to TypicalTypical
waterproofing
waterproofing
requirements
engineers requirements engineers Typical membrane
membraneapplied applied
to to Typical waterproofing
waterproofing
Polyurethane sealant placed under AFS floor
requirements requirements membrane
wall, overlaid
wall, overlaid
with
to with membrane applied
applied
track, prior to fixing. (Optional floor track referto
wall,“coreflute”
“coreflute”
overlaid withas approved
as approved
to engineers specifications) wall, overlaid with
“coreflute” as approved “coreflute” as approved
StarterStarter
bars 600mm
bars 600mm min. min.
intobars
wall
intopanel
wall panel
tomin.
project
to project
Starter 600mm Concrete slabStarter bars 600mm min.
and edge
engineers
engineers
details
into wall panel tobeam details
project into wall panel to project
to engineer’s
engineers detailsdetails engineers details
Flashing
Flashing
at slabatlevel
slab level
Flashing at slab level Flashing at slab level
Polyurethane
Polyurethane
sealantsealant
placedplaced
underunder
AFS floor
AFS floor
track,track,
Polyurethane prior to
prior
fixing.
sealant to fixing.
(Optional
placed (Optional
floor
Polyurethane
under track
floor
AFS floor refer
track refer
sealant placed under AFS floor
track,toprior
engineers
totoengineers
specifications)
fixing. specifications)
(Optional track, prior refer
floor track to fixing. (Optional floor track refer
to engineers specifications) to engineers specifications)

Concrete
Concrete
slab and
slabedge
and edge
* Alternatively Basement Walls can be constructed using REDIWALL, another product by AFS.
beamslab
beam
to engineer’s
to edge
engineer’s Concrete slab and edge
Concrete and
beamdetailsdetails
to engineer’s beam to engineer’s
details details

Draft v10 30/4/12

* Alternatively
* Alternatively
Basement
Basement
Walls Walls
can becan
constructed
be constructed
using using
REDIWALL,
REDIWALL,
another
www.rediwall.com.au another
productproduct
by AFS.
by AFS.
* Alternatively Basement Walls* can
Alternatively Basement
be constructed Walls
using can be constructed
REDIWALL, usingbyREDIWALL,
another product AFS. another product by AFS.

150 DraftDraft
v10 v10
30/4/12
30/4/12
Draft v10
Draft v10 30/4/12 DESIGNER 30/4/12
2012 WALLING SOLUTIONS

www.rediwall.com.au
www.rediwall.com.au
www.rediwall.com.au www.rediwall.com.au

150 150 155


150 150DESIGNER
DESIGNER
20122012 DESIGNER 2015 WALLING SOLUTIONS
WALLING SOLUTIONS
DetailDetail
#8 #8

Architectural Detailing
AFS Retaining Wall Slab Junction
Architectural Detailing

AFS Retaining Wall SlabOption


Junction
B
Option B
I 2.1.11 AFS LOGICWALL® Retaining Wall / Basement Wall Footing Junction
I 2.1.11 AFS LOGICWALL® Retaining Wall / Basement Wall Footing Junction

I
I

Wall thickness to project


Maximum depth of fill specifications
Wall thickness to project
to engineers detail specifications

AFS LOGICWALL
AFS LOGICWALL

Vertical and horizontal


Vertical and horizontal reinforcement to engineer’s
details
reinforcement to engineer’s
Backfilled to details
Typical waterproofing
Backfilled to engineers Typical waterproofing membrane applied to
engineers requirements membrane applied to wall, overlaid with
requirements wall, overlaid with “coreflute” as approved
“coreflute” as approvedStarter bars 600mm
Starter bars 600mm min. into wall panel to
min. into wall panel to engineers details
engineers details
Flashing at slab level
Flashing at slab level
Polyurethane sealant placed under AFS floor
track, under
Polyurethane sealant placed prior to fixing.
AFS floor(Optional floor track refer
to engineers
track, prior to fixing. (Optional specifications)
floor track refer
to engineers specifications)
Floor slab to
Floor slab to engineer’s details
engineer’s details

Footing to
Footing to engineer’s details
engineer’s details

* Alternatively Basement Walls can be constructed using REDIWALL, another product by AFS.
* Alternatively Basement Walls can be constructed using REDIWALL, another product by AFS.
Draft v10 30/4/12
Draft v10 30/4/12

www.rediwall.com.au
www.rediwall.com.au

156 WALLING SOLUTIONS DESIGNER 2012 151


WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Detail #37

Architectural Detailing
I 2.1.12 Wall Slab Junction, Beam System Parallel To AFS LOGICWALL®
Wall slab Junction, Beam system
parallel to AFS Wall
I

I
INTERNAL EXTERNAL

AFS LOGICWALL

Vertical and horizontal


reinforcement to engineer’s
details

Horizontal joint can


be treated with any
of the options from the
horizontal joint
details

Reinforcement to
engineer’s details
Beam system Dimension
as specified AFS LOGICWALL steel frame
in slab zone to be cut
out on site if required

External finishes to
project’s specification
(Refer Recommended
Finishes Schedule).

152 157
Draft v3 20/9/11 DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

Detail #38
I 2.1.13 Wall Slab Junction, Beam System Perpendicular to AFS LOGICWALL®
Wall slab Junction, Beam System
Perpendicular to AFS Wall

I
I

Vertical and horizontal


reinforcement to engineer’s
details
Slab reinforcement
to engineer’s details

Slab beam Beam bearing on AFS LOGICWALL walls,


system to engineer’s details

AFS LOGICWALL

Draft v3 20/9/11

158 153
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Detail #45

Architectural Detailing
I 2.1.14 Wall Slab Junction, Beam System Perpendicular to AFS LOGICWALL® Façade Wall
Wall slab Junction, Beam System
Perpendicular to AFS Facade Wall
I

I
EXTERNAL

Vertical and horizontal


reinforcement to engineer’s
details
Slab reinforcement
to engineer’s details

Slab beam Horizontal joint can


system be treated with any
of the options from the
horizontal joint
details

Beam bearing on AFS LOGICWALL walls,


to engineer’s details

AFS LOGICWALL

154 159
Draft v3 20/9/11 DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

Detail #40
I 2.1.15 Permanent Formwork, Junction To AFS LOGICWALL® Façade Wall
(i.e. Bondek or similar metal floor system)
Permanent Formwork, Junction to
AFS Facade Wall (i.e. Bondeck or Similar

I
Metal Floor Systems)
I

EXTERNAL

AFS LOGICWALL

Vertical and horizontal


reinforcement to engineer’s
details

Horizontal joint can


be treated with any
of the options from the
horizontal joint
details

Reinforcing bars
to engineer’s details
Bondek

Bondek bearing AFS LOGICWALL steel studs


on AFS LOGICWALL walls in slab zone, to be cut
to engineer’s details out on site if required
Tek screw each panel

160 155
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #41
Typical Opening in Wall
Architectural Detailing

Architectural Detailing
I 2.1.16 Permanent Formwork, Junction To Internal AFS LOGICWALL® (i.e. Bondek or
similar metal floor system)
I

I
Concrete floor slab,
to engineer’s details

Bondek

Angle screwed to
top of AFS LOGICWALL
to support Bondek
to engineer’s details

AFS LOGICWALL

Draft v3 20/9/11

156 161
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #15

Architectural Detailing
Architectural Detailing

Step Floor/Stair Landing Detail

I 2.1.17 Step Floor/Stair Landing

AFS LOGICWALL

I
I

Wall thickness to project


specifications

For AFS LOGICWALL edgeform detail


refer to chapter J, fig J5.1.4
for joint finishing Concrete floor slab
to engineer’s details

Concrete wall to
slab cold joint

Formwork

Horizontal and vertical


reinforcing to
project engineer’s
Intermediate concrete specifications
slab

Formwork

Starter bars to intermediate


slab, as specified by engineer.
(FC sheeting can be removed on site as
specified by the engineer’s detail)
NOTE: Consult AFS technical
representative before specifying
this detail.

Draft v3 20/9/11

162 157
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
Detail #30
I 2.1.18 AFS LOGICWALL® Wall Connections To Stair Mid Landing

AFS Wall Connection to


Stair mid landing
I

I
Starter bars to stair landing slab,
as specified by engineer.
(FC sheeting can be removed on site
as required by engineers details)

Fire escape stair


Horizontal and
mid landing, to
vertical
engineer’s details
reinforcement to
structural
engineer’s
details

Formwork

AFS LOGICWALL

158 163
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

I 2.2 Post-tensioned Slabs

Detail #9
I 2.2.1 AFS LOGICWALL® Post-tensioned Detail

I
I

AFS Post Tension Detail

Vertical and horizontal


reinforcement to engineer’s
details

AFS LOGICWALL

Two continuous beads of


sealant under floor track on
all external walls and
internal separation walls by AFS
Joint LOGICWALL installation contractor
treatment Paintable waterproofing membrane
as per
details I2.1.1
to I2.1.4 Alternative PT floor plan option
(as specified by structural design)

Tensioning cable

Concrete floor slab to


engineer’s details

Slip joint required Steel clinching angle and AFS LOGICWALL


to structural framewithin slab zone (Can be removed
engineer’s details onsite where required).
50mm PVC sleeve over starter
bars in slab zone (grouted
after initial tension)

AFS LOGICWALL

Draft v6 29/11/11

164 159
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
Detail #35
I 2.2.2 Post-tensioned Slab To AFS LOGICWALL® (Internal) Wall

Post Tensioned Slab to


I

AFS Internal Wall

I
AFS LOGICWALL

Vertical and horizontal


reinforcement to engineer’s
details

ø50mm sleeve to be
Post tensioning filled with non shrink grout
duct after post-tensioning

Slip joint required to


structural engineer’s details

160 165
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

Detail #11
I 2.3 AFS LOGICWALL Corners and Tee Junctions
I 2.3.1 AFS LOGICWALL® Wall 90° Prefabricated Corner - Single Reinforcement Carriers (AFS120,
150, 162, 200) AFS 90º Prefabricated Corner

I
I

INTERNAL EXTERNAL

Horizontal bar
Factory installed corner bars as lap to engineer’s
per engineer’s specifications details
Note: Alternative hook bar
reinforcing can be adopted to
engineer’s specifications.

90º (+-8º)
AFS LOGICWALL

Refer to chapters
E, F & J for finishing
options.

Maximum dimension 750mm


Penetration for horizontal bar
placement performed on site
External finishes to
project’s specification
(Refer Recommended
Finishes Schedule).

Draft v6 29/11/11

166 161
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
I 2.3.2 AFS LOGICWALL®
Detail #44
Wall 90° Prefabricated Corner – Double Reinforcement Carriers - with
"L" bars (AFS200D, 262D)
AFS 90º Prefabricated Corner
AFS 200D and AFS 262 Wall
I

I
AFS LOGICWALL

Factory installed corner bars as


per engineers specifications
NOTE: Alternative hook bar
reinforcing can be adopted to
engineer’s specifications

90º (+-8º)

Refer to chapters
E, F and J for
finishing options

Maximum Dimension 750mm

Draft v10 30/4/12


162 167
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing
Architectural Detailing

I 2.3.3
I 2.3.3
"U"bars
AFSAFS
"U"bars
LOGICWALL
(AFS200D,
(AFS200D,
® Wall
LOGICWALL
262D)
® Wall

262D)
90°90° Detail
Detail#48
Prefabricated #48
Prefabricated
Corner
Corner
– Double
– Double
Reinforcement
Reinforcement
Carriers
Carriers
- with
- with

Alternate
Alternate
AFS
AFS
90º90º
Prefabricated
Prefabricated
Corner
Corner

I
I
AFS
AFS
200D
200D
andandAFS
AFS262
262
Wall
Wall
I

INTERNAL EXTERNAL

AFS AFS
LOGICWALL
LOGICWALL

Factory
Factory
installed
installed
corner
corner
U-bars
U-bars
as per
asengineers
per engineers
specifications
specifications

90º (+-8º)
90º (+-8º)

ReferRefer
to chapters
to chapters
E, F and
E, F Jand
forJ for
finishing
finishing
options
options

Maximum
Maximum
Dimension
Dimension
750mm
750mm

External finishes to project’s specification


(Refer Recommended Finishes Schedule).

Draft
Draft
v10v10
30/4/12
30/4/12
168 163 163
WALLING SOLUTIONS
WALLING SOLUTIONS DESIGNER 2015 DESIGNER
DESIGNER
2012
2012
Architectural Detailing

Architectural Detailing
Detail #12
I 2.3.4 Squint Corner Detail for 135° Corners or Angle
Squint Corner Detail for 135º
Corners or Angle to Suit Design
I

I
Horizontal and vertical
reinforcing steel to structural
engineers design supplied by
builder lap only, no cog

Ends of the lining trimmed to


suit dimension
required by AFS LOGICWALL
Temporary insallation contractor
galvanised angle.
Remove after
concrete pour

AFS LOGICWALL

Temporary
galvanised angle.
Refer to chapters Remove after
E, F and J for concrete pour
finishing options

Draft v6 29/11/11

164 169
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Detail #10
Architectural Detailing

I 2.3.5 AFS LOGICWALL® Wall Tee Junction


AFS Wall Tee Junction

I
I

AFS
AFS LOGICWALL
LOGICWALL

AFS LOGICWALL AFS


AFS LOGICWALL
LOGICWALL Joiner
Joiner Stud
Stud
LOGICWALL
supplied withsupplied
vertical
with vertical
joints joints
recessed.
recessed.
Flushed on Flushed
site on site

Tee
Tee Junction
Junction StudStud
fixed
fixed to
to wall
wall face
face at
at
450mm
450mm centres
centres

Fibre cement
Fibre cement removed
removed from
from
each hole
each hole in
inAFS
LOGICWALL studstud
LOGICWALL
(performed on
(performed on site)
site)

Horizontal and
Horizontal and vertical
vertical
reinforcing to
reinforcing to structural
structural
engineer’s details
engineer’s details

170 165
Draft v6 29/11/11 WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Detail #16

Architectural Detailing
I 2.4 Panel Joints
Structural Movement Joint
I 2.4.1 Movement Joint
I

I
(Installed where nominated by project
EXTERNAL
engineer - must be clearly documented
on drawings. Typically not required in
walls less than 16m in length.)
Backing strip and
fire rated sealant
EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
(REFER RECOMMENDED
FINISHES SCHEDULE).

AFS LOGICWALL
AFS LOGICWALL Prefabricated
AFS LOGICWALL endcap
stud site installed
by AFS LOGICWALL
installation contractor

INTERNAL
NOTE: Can be dowel jointed if required
structurally. Must be clearly specified and
negotiated with installers at time of tender

Draft v3 20/9/11

166 171
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #17

Architectural Detailing
Architectural Detailing

Fibre Cement Sheet Surface Joint


I 2.4.2 Fibre Cement Sheet Surface Joint (Vertical)

I
I

EXTERNAL INTERNAL

Joint taped and set in


Cut for expansion joint after accordance with
setting is complete (2-4mm manufacturer’s
wide through depth of fibre specifications
cement sheet). Fill groove with
flexible sealant

AFS LOGICWALL

NOTE: Locations
EXTERNAL for TO
FINISHES sheet
PROJECT’S SPECIFICATION
surface joints are
(REFER RECOMMENDED
to be
nominated by project
FINISHES SCHEDULE).
consultants and are required
every 6 metres nominally

Draft v3 20/9/11
172 167
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #14
Architectural Detailing

Architectural Detailing
Double Height Wall Detail
I 2.4.3 Double Height Wall – Horizontal Joint
I

I
AFS LOGICWALL

Vertical and horizontal


reinforcement bars as
specified by project
engineer’s details
Panel B

EXTERNAL INTERNAL
AFS LOGICWALL track member fixed
to concrete in panel A, to take panel B
Recess for flushing
(performed on site by AFS LOGICWALL
horizontal joint,
150 - 300mm

installation contractor)
to be ground on site
Panel A

EXTERNAL FINISHES TO NOTE: Issues regarding


PROJECT’S SPECIFICATION access, lifting and bracing
(REFER RECOMMENDED
FINISHES SCHEDULE). need to be considered when
specifying this detail

Draft v6 29/11/11
168 173
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

I 2.5 Boundary Walls Detail #32


I 2.5.1 AFS LOGICWALL® Wall Adjacent To Existing Structure Flashing Detail
LOGICWALL to Neighbouring

I
Building Flashing Detail
I

EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION (REFER
RECOMMENDED FINISHES SCHEDULE).

AFS LOGICWALL
Vertical and horizontal
reinforcement bars as External acrylic
specified by project render system
engineer’s details
Cut thought fibre cement sheeting and treat
cut area with suitable waterproofing
membrane after installing flashing
Waterproofing
sealant

Flashings

INTERNAL EXTERNAL

174 169
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Detail #33

Architectural Detailing
I 2.5.2 Unfinished CoveredAFS
Boundary Wall FlashingBoundary
Unfinished Detail Wall
Flashing Detail
I

I
Vertical and horizontal
reinforcement to engineers
details

AFS LOGICWALL

Two continuous beads of


Continuous bead
sealant under floor track on
of AFS LOGICWALL
all external walls and
structural adhesive
internal separation walls
by AFS LOGICWALL
by AFS LOGICWALL installation contractor
installation contractor

Concrete floor slab to


Flashing
engineer’s details

Steel clinching angle and


AFS LOGICWALL frame within
slab zone. (Can be removed
onsite where required).

Concrete wall to
slab cold joint

This detail only applies where waterproof flashing to adjacent building is not achievable as per detail I 2.5.1

THIS DETAIL ONLY APPLIES WHERE WATERPROOF FLASHING IS NOT ACHIEVABLE AS PER DETAIL I2.5.1

Draft v6 29/11/11

170 175
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Detail #49
Architectural Detailing

I 2.5.3 Safety Balustrade / Boundary Wall Detail


LOGICWALL Balustrade/
Boundary Wall Detail

I
I

AFS LOGICWALL panel

Formwork

AFS LOGICWALL studs


extend 40mm to
locate panel above

Concrete pour 3
Wall Brace
Tape and set
external joint

1000mm
Horizontal and vertical
“L” bar reinforcing to
project engineers
specifications
Concrete floor slab
to engineer’s details

Concrete pour 2

Formwork

Concrete pour 1
Cut out fibre cement board on
site. Starter bars to intermediate
slab, as specified by engineer,
supplied by builder

Draft v8 27/3/12

176 171
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
Detail #22
I 2.6 Junctions with Other Wall Types

I 2.6.1 AFS LOGICWALL®/Plasterboard Wall Junction


AFS Wall/Plasterboard
Wall Junction
I

I
Stud, track and
plasterboard

Wall fixing to architect’s


specification
AFS LOGICWALL

Site installed
end cap

Paintable sealant,

Setting “L” Bead,

Plasterboard,

Plaster set,

Draft v6 29/11/11

172 177
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

Detail #21
I 2.6.2 AFS LOGICWALL®/Double Brick Junction
LOGICWALL/Double Brick Junction

I
I

If brickwork is external or wet


area, seal the fibre
cement/concrete with paintable
water proof membrane prior to
laying of bricks or application of
any finishes. Ensure product
used is compatible with
specified finishes

Set “L” bead


AFS LOGICWALL
Site installed
end stud

Brick ties fixed to AFS


LOGICWALL using masonry
nails or other suitable fixings
as specified.

Paintable Waterproof end of AFS


sealant LOGICWALL with suitable
membrane. Paint prior to
laying of brick walls

White set cement


render or plasterboard

Draft v10 30/4/12

178 173
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
Detail #23
I 2.6.3 AFS LOGICWALL®/Brick Veneer Junction
AFS Wall/Brick Veneer Junction
I

I
Studs fixed to AFS LOGICWALL
using masonry nails or
other appropriate fixings
as specified
Set “L” bead

AFS LOGICWALL
Site installed
end stud

Brick ties fixed to AFS


LOGICWALL wall using masonry
walls or other suitable fixings
as specified

Waterproof end of AFS LOGICWALL


wall with suitable membrane.
Paintable Paint prior to laying of brick
sealant walls

Studs, track and Brickwork


Plasterboard

Draft v10 30/4/12

174 179
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

I 2.6.4 Brick Veneer Facade Over AFS LOGICWALL®

I
I

Foil board insulation


placed over brick ties
if specified

Flush set and paint


or overclad as per Brick
finishing options set out
in Chapter E

AFS LOGICWALL

Brick ties

Water proofing of slab set down


as per architects specifications

180 175
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
Detail #18
I 2.7 Doors, Windows & Openings

Fire
I 2.7.1 Fire Door Frames - Manufactured Door
to suit Frames® Profile - Option 1
AFS LOGICWALL
I

I
OPTION 1
Use “L” Bead and flush set to create
“Shadow Line”

Door frame glued and


screwed to inside of AFS LOGICWALL
panel at 400mm Centres Throat size of door
AFS LOGICWALL
frame to match
internal dimension
of AFS LOGICWALL

Door frame is core


filled during the
core filling of AFS LOGICWALL

Metal straps at 1m
Horizontal and vertical OPTION 2 centres (vertically
reinforcement to Flush set sheet recess to inside the frame) by
structural engineers fire door frame frame manufacturer
specifications

Note: Fire door frame to be braced on site to prevent movement/twisting during concrete corefilling.

Draft v6 29/11/11

176 181
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #19

Architectural Detailing
Architectural Detailing

Alternative Fire Door Frames


I 2.7.2 Alternative Fire Door Frames - Manufacured to suit AFS LOGICWALL® Profile - Option 2

I
I

Temporarily screw
AFS LOGICWALL fixed prior to pour Site installed
end stud

Door frame is
core filled
during the core filling
of AFS LOGICWALL

Horizontal and vertical Metal straps at 1m


reinforcement to Throat size of door centres (vertically
structural engineers frame to match inside the frame) by
specifications by others AFS LOGICWALL frame manufacturer

Note: Fire door frame to be braced on site to prevent movement/twisting during concrete corefilling.

182 177
WALLING SOLUTIONS
Draft v6 29/11/11
DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Detail #20

Architectural Detailing
I 2.7.3 Alternative Non-Fire Rated Door Frames
Alternative Non-Fire
Rated Door Frames
I

I
AFS LOGICWALL

Site installed
end stud by
AFS LOGICWALL Set flush to panel
installation contractor face for clean
finish, by others

Screw fix end cap


at 200mm centres
prior to filling
To suit AFS LOGICWALL

Perforated
sides

35mm to 100mm 35mm to 41mm

All door frame components are


supplied and installed by others

Note: Door frame to be braced on site to prevent movement/twisting during concrete corefill.

178 183
Draft v6 29/11/11 DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #27

Architectural Detailing
Architectural Detailing

Commercial Window Section


I 2.7.4 Commercial Window Section

I
I

AFS LOGICWALL

Prefabricated end cap


Extra reinforcing bars above section installed on
and below opening - as per site to head & stile
project engineer’s specification
supplied

Fibre
cement
sheet

Seal the vertical and horizontal


fibre cement/concrete window
surrounds with paintable water
proof membrane prior to fitting
of subframe or application of
any finishes, by others. Ensure
product used is compatible
with specified finishes

Subsill

Draft v6 29/11/11
184 179
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
I 2.7.5 Rebated Window Section
I

I

AFS LOGICWALL

180 185
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #39

Architectural Detailing
Architectural Detailing

Typical Opening in Wall


I 2.7.6 Opening In Wall

I
I

AFS LOGICWALL

Prefabricated end cap section


Extra reinforcing bars above to be installed on site
and below opening - As per to head and stile panels
project engineers specification

Fibre cement

External acrylic render applied Seal the vertical and horizontal


finishes as detailed in chapters fibre cement/concrete window
F and J. surrounds with paintable water
proof membrane prior to fitting
of subframe or application of
any finishes, by others. Ensure
product used is compatible
with specified finishes

Trowel finish concrete, to


be water proofed prior to
window installation

Draft v6 29/11/11

186 181
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
I 2.8 Cast In Elements

I 2.8.1 Cast In Lift Rails


I

I
AFS LOGICWALL

AFS LOGICWALL on
AFS LOGICWALL installation contractor

AFS LOGICWALL

182 187
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #25

Architectural Detailing
Architectural Detailing

Services Detail
I 2.8.2 Services

I
I

Slab Zone

Suspended Ceiling Zone

Locate in slab
zone or ceiling
void, by others

AFS LOGICWALL
Electrical
conduit as per
specification
by others

Temporary screw to
secure conduit in
box, by others

Face plate box


temporarily secured by
render plate during
Gas bayonet as specified concrete pour, by others

Draft v6 29/11/11
188 183
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #31
Architectural Detailing

Architectural Detailing
I 2.9 Balcony Walls Balcony Wall Detail
I 2.9.1 Balustrade Wall
I

I
Top of AFS LOGICWALL wall
Trowel finished balustrade panel is
concrete waterproofed and
texture coated, over
PVC render angles to
suppliers specifications

Balcony upstand and slab are


water proofed as specified AFS LOGICWALL

Balcony slab Line of first pour


Tiles on balcony
to engineers including skirting tile
details

Formwork Recess and bead Fillet for drip Reinforcement as Temporary


seal to stop water groove detailed by project conventional
penetration engineer bracing

Draft184
v10 30/4/12 189
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Detail #28

Architectural Detailing
Architectural Detailing

LOGICWALL
I 2.9.2 Balcony Dividing Wall Balcony Dividing
Wall Detail

I
I

Vertical and horizontal


reinforcement to engineer’s
details

AFS LOGICWALL

Two continuous beads of


sealant under floor track on
all external walls and
internal separation walls
Waterproof membrane
by AFS LOGICWALL installation
both sides as specified
contractor

Paintable
waterproofing
Tiles
membrane

Concrete slab, to engineer’s


details

Draft v6 29/11/11

190 185
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing
I 2.9.3 Balcony Wall Detail Without HOB

I
EXTERNAL

EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
(REFER RECOMMENDED
FINISHES SCHEDULE).

191
DESIGNER 2015
Architectural Detailing

I 2.9.4 Balcony Wall Detail With HOB


I

EXTERNAL

EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
(REFER RECOMMENDED
FINISHES SCHEDULE).

192
DESIGNER 2015
Architectural Detailing

Architectural Detailing
Detail #34
I 2.10 Timber Component Connections

I 2.10.1 AFS LOGICWALL® Wall Timber Floor Junction

AFS Timber Floor Junction


I

I
AFS LOGICWALL

Approved masonry Timber floor system,


anchor fixing to to engineer’s details
engineer’s
specification

Triple grip fixing,


by others

Horizontal timber
bearer to engineer’s
specification

186 193
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing

I 2.10.2 Timber Top Plate Connection


I

194
DESIGNER 2015
Detail #13
Architectural Detailing

Architectural Detailing
AFS Blade Wall Detail

I 2.11 Blade Walls

I 2.11.1 AFS LOGICWALL® Blade Wall


I

I
Fibre cement Prefabricated
AFS LOGICWALL endcap
stud installed on site

PVC 90º setting


beads

AFS LOGICWALL Applied finishes

EXTERNAL FINISHES TO
PROJECT’S SPECIFICATION
Horizontal and vertical
(REFER RECOMMENDED
reinforcing to structural
FINISHES SCHEDULE).
engineer’s details

Draft v6 29/11/11

188 195
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

I 2.12 Acoustic & Thermal Details Detail #36


I 2.12.1 AFS LOGICWALL® External Wall with Foil Board

AFS External wall with Foil Board,

I
I

Battens & Plasterboard

AFS LOGICWALL

Battens

(Beta-Fix) wall clip

EXTERNAL INTERNAL

Plasterboard

Foil Board/insulation
External finishes to
project specifications
(Refer recommended
finishes schedule)

196 189
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Detail #42
Architectural Detailing

Architectural Detailing
I 2.12.2 AFS LOGICWALL® SeparatingAFSWall
Separating Wall
– Wet Area/Living Area or Wet to Wet Area where
plumbing services are to be installed
Wet Area/Living Area
I

I
Discontinuous
Steel or timber
lightweight
stud wall

AFS LOGICWALL

WET AREA LIVING AREA

Wet area
cladding
sheet

Waterproofing as specified

Concrete floor slab


to engineer’s details

Draft v6 29/11/11

190 197
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

I3 Architects Standard Notes

Whilst architectural requirements vary from project to project can be adopted and used across most projects incorporating
the architectural specifications may be similar. AFS LOGICWALL®.

I
I

The following AFS LOGICWALL® Architectural Standard Notes A NATSPEC 0310p "AFS LOGICWALL® In Concrete Combined"
specification is also available.

ARCHITECTS STANDARD NOTES

198 191
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
I3 Standard Architectural Notes continued
I

192 199
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
Architectural Detailing
Architectural Detailing

I3 Standard Architectural Notes continued

I
I

200 193
WALLING SOLUTIONS DESIGNER 2015 DESIGNER 2012
Architectural Detailing

Architectural Detailing
I4 BIM Software

BIM (Building Information Modeling) has gained acceptance in To assist with the design and documentation of AFS
recent years and is used for the design of many buildings today. LOGICWALL® walls, AFS provide a complete package of
I

There is a range of BIM software packages now available on standard details, library parts/ objects, wall families and 3D

I
the market, each providing consultants and building designers model components in the following file types:
flexibility and ease of design.
ƒ Revit
Whilst there have been some basic modeling programs ƒ ArchiCad
available in the past, recent technical advancements have ƒ DWG
allowed the introduction of more advanced BIM Software ƒ PDF (Standard Details)
programs, such as Revit and Archicad, which are more versatile
and allow designers, architects and engineers to build their
projects on the screen as a comprehensive 3D model. These
models provide consultants with a detailed view of the scope
of their projects whilst providing subcontractors, tenderers and
clients a complete 3D overview of their scope of works, as they
embody significant amounts of project information.
NO
This
must
draw
discr
draw

LOT 1532 CAVENAGH ST - MIXED-USE DEVELOPMENT DRAWING TITLE:


PERSPECTIVE 7

PROJECT NAME: C
LOT 1532 CAVENAGH ST - MIXED-USE -
DEVELOPMENT
PROJECT NUMBER: SCALE: DRAWN D
1101 Author A

194 201
DESIGNER 2012 DESIGNER 2015 WALLING SOLUTIONS
I Architectural Detailing

202
I
Notes

DESIGNER 2015
I Legal Statements

Architectural Detailing
IMPORTANT LEGAL STATEMENTS
Reasonable efforts have been made to ensure the accuracy of this publication; however, any information and data
contained herein is subject to change without notice. To ensure the information you are using is correct, AFS
recommends you review the latest technical information available on the AFS website www.afswall.com.au, or

I
alternatively call 1300 727 237 to speak to a Technical Representative.
The AFS logo and LOGICWALL® mark are registered trade marks. © 2015 AFS Systems Pty Ltd.
No part of this publication may be reproduced in any form or by any means without prior written permission
from AFS Systems Pty Ltd. All rights reserved.

DISCLAIMER
1. This technical manual named AFS Designer together with the design tables and associated information
related to AFS LOGICWALL® has been prepared by AFS to assist design professionals using AFS
LOGICWALL® including without limitation, developers, builders, engineers, architects or quantity surveyors
with the design of structural walls.
2. It is the responsibility of the user to ensure that the use of this manual is appropriate and to exercise their own
judgment when using this manual.
3. AFS does not accept any responsibility (whether for negligence or otherwise) for any consequence arising from the
use or application of this manual.
4. The design and engineering of the structure of any building using AFS LOGICWALL® should only be undertaken by
suitability qualified and experienced design professionals, engineers or consultants.
5. The full responsibility for the design, engineering and structural design, and certification of compliance with
all relevant Australian Standards, BCA and any other statutory requirements at Local, State and Federal levels
rest with the design professional, project engineer or project consultants including but not limited to the design
engineer, acoustic consultant, energy efficiency consultant, fire engineer and any of their officers, employees,
delegates, partners, agents and service providers of any nature.
6. AFS reserves the right to change the specifications of this manual without notice.
7. Please check with AFS that you have the latest version as the manual may be updated from time to time and
certain details may change.
8. This disclaimer applies to the extent permitted by law.

DEFINITIONS
The use of the terms ‘AFS LOGICWALL®’ and ‘AFS LOGICWALL® Walls’ throughout the AFS Designer are as follows;
AFS LOGICWALL®: Refers to AFS LOGICWALL® panels as permanent formwork prior to being installed & corefilled with concrete.
AFS LOGICWALL® Walls: Refers to AFS LOGICWALL® walls installed with concrete corefill incorporated.

W DESIGNER 2015
Distributed by:
IMPORTANT LEGAL INFORMATION
AFS SYSTEMS PTY LTD Reasonable efforts have been made to ensure the accuracy of this publication; however, any information
PO Box 234, Minto NSW 2566 and data contained herein is subject to change without notice. To ensure the information you are using
110 Airds Road, Minto NSW 2566 is correct, AFS recommends you review the latest technical information available on the AFS website
www.afswall.com.au, or alternatively call 1300 727 237 to speak to a Technical Representative.
Phone: 1300 727 237
The AFS logo and LOGICWALL® mark are registered trade marks. © 2015 AFS Systems Pty Ltd.
Email: afssales@csr.com.au
No part of this publication may be reproduced in any form or by any means without prior written
Web: www.afswall.com.au ABN 45 576 072 788
permission from AFS Systems Pty Ltd. All rights reserved.