In this post you'll find step by step instructions for initial OLT configuration and for setting up the IP
connectivity of any HUAWEI OLT. After completing these steps, you'll be ready to connect your OLT to
SmartOLT.
telnet 10.11.104.2
Trying 10.11.104.2...
Connected to 10.11.104.2.
>>User name:root
>>User password:
MA5608T>
MA5608T> enable
MA5608T#
Step two:
Display and confirm the detected OLT boards.
MA5608T>
MA5608T> enable
MA5608T# config
MA5608T(config)# display board 0
Step three:
Configure your allocated management IP address for this OLT, in this example it's 10.100.0.2, with default
gateway 10.100.0.1 on the out-of-band meth0 ETH interface:
MA5608T> enable
MA5608T# config
MA5608T(config)# interface meth0
MA5608T(config)# ip address 10.100.0.2 255.255.255.0
Step four:
Create a dedicated username/password. This user/pass will be used by SmartOLT to connect to your OLT.
MA5608T> enable
MA5608T# config
MA5608T(config)# terminal user name
User Name(length<6,15>): smartoltusr
User Password(length<6,15>): (insert a strong password here)
Confirm Password(length<6,15>): (confirm the password)
User profile name(<=15 chars)[root]: (press ENTER)
User's Level:
1. Common User 2. Operator 3. Administrator: 3
Permitted Reenter Number(0--4): 4
User's Appended Info(<=30 chars): (press ENTER or a comment like SmartOltUser)
Adding user successfully
Repeat this operation? (y/n)[n]: n
# Other general settings (If you use SmartOLT, these are configured automatically, no need to
configure them manually):
MA5608T>
MA5608T> enable
MA5608T# config
MA5608T(config)# autosave interval 1442
MA5608T(config)# autosave type all
MA5608T(config)# autosave interval configuration 480
MA5608T(config)# autosave interval on
MA5608T(config)# ntp-service unicast-server 91.189.89.199
MA5608T(config)# ntp-service unicast-server 80.96.196.58
# Optionally, you can configure an "in-band" IP address on a VLAN interface. This is useful when you want
to manage the OLT using the same physical interface that is used for normal traffic of the customers.
We do not recommend this scenario because if a loop happens in the ONT, undetected by the ONT/OLT
and the uplink port is shutdown by the uplink device as a reaction to the loop, you will lose the IP connectivity
with the OLT as well.
MA5608T> enable
MA5608T# config
MA5608T(config)# interface vlanif 100
MA5608T(config)# ip address [IP] [MASK]