3. Connection/installation L
220-230V~
50-60Hz
C2 4 µ5 6 L
220-230V~
50-60Hz
L
220-230V~
50-60Hz
R 3a -20T R 3a -20T R 3a -20T R 3a -20T

Tempus Digital BZT28371, BZT28372 PROG TIME DATE SU/ WI PROG TIME DATE SU/ WI
WARNING PROG TIME DATE SU/ WI PROG TIME DATE SU/ WI

SIMPLEXA 602

SIMPLEXA 601
SIMPLEXA 602

SIMPLEXA 601
12 31 12 31 12 31 12 31
Warning, danger of death through electric
Installation and operating instructions AM AM AM AM

Digital Day/Week Timer 1 CO/2 CO


PM
shock!
PM PM PM

- + - + ESC - + OK - +
Clock Operated Switch
ESC
Res 1 2
OK ESC
Res
OKDisconnect power source. Res 1 2
ESC
Res
OK

 Cover or shield any adjacent live components.


L L

C1 1 16-12
M

C1 1
 Ensure device cannot be switched on!
16-12
M
C1 1 µ2 16-12
M

C1 1 µ2 16-12
M

µ2 3 µ2 3 3 3
AWG N AWG N AWG N AWG N
 Check power supply is disconnected.
1. Basic safety instructions  Earth and bypass.

WARNING
Danger of death through electric shock or fire!
 Installation should only be carried out by C2 4 µ5 6 L L C2 4 µ5 6 L L
220-230V~ 220-230V~ 220-230V~ 220-230V
16(6)A 250 V~ 50-60Hz 50-60Hz 16(6)A 250 V~ 50-60Hz 50-60Hz

professional electrician. R 3a -20T R 3a -20T R 3a -20T R 3a -20

BTZ28372
BTZ28372
• The device is designed for installation on DIN top hat rails

BTZ28371
(in accordance with IEC/EN 60715)
with- + OK
• Corresponds to type 1 B actions in accordance ESC Res 1 2
ESC
Res
- + OK ESC
Res
- 1
+
2
OK ESC
Res
- + OK

IEC/EN 60730-1 L L L L

16(6)A 250 V~ M 16(6)A 250 V~ M


16(6)A 250 V~ M 16(6)A 250 V~ M

Designated use C1 1 µ2 3 N 1 µ2 3
N
C1 1 µ2 3 N 1 µ2 3
N

• The clock operated switch is used for lighting, ventilation,


flushing etc. applications
N N N
• Only for use in closed, dry rooms. L1 L1 L1
L2 L2 L2
• Do not use on safety devices, e.g. escape route doors,
BZT28371 BZT28372
fire safety equipment etc.

Disposal
4. Overview of menu selection
C2 4 µ5 6 L L C2 4 µ5 6 L

Dispose of device in environmentally sound manner C 16(6)A 250 Vac


602 0 001
220-230V~
50-60Hz
R 6a -20T C 601 0 001
220-230V~
50-60Hz
R 6a -20T
16(6)A 250 Vac
602 0 001 C
220-230V~
50-60Hz
R 6a -20T 601 0 001 C
220-23
50-60
R 6a -

ESC

 PROG  TIME
 DATE
 SU/ WI

2. Screen and keys 12 31
END

Set the date * CHANNEL HOUR YEAR ––:––


Set time
MEMORY MINUTE MONTH EU
Set switching times Set summer/winter time
PROG TIME DATE SU/ WI
12 31 Display permanent On/Off DAY USA
Storage location switching
HOUR CDN
AM Display time
Channel number PM

-
2 dots flash: MINUTE * only with BZT28372
Days of the week ESC OK Nominal voltage OK
 ...

Channel status 3 dots flash: WEEK


Res  1  2
DAY
ON = On PROG TIME DATE SU/ WI Power reserve operation
12 31
OFF = Off

AM
PM
5. Initial start-up
 ESC
– Activate screen
ESC
Res
-
 1  2
OK  OK
– Store selection
The device is not preset. Date, day of the week (1 ... 7),
– Open menu – Confirm selection time format (12h AM/PM or 24 h) and time must be set.
– Cancel menu
– Leave menu Press any button and follow on-screen instructions.


(see fig.).

ESC
RESET/complete deletion
 YEAR  MONTH  DAY  DAY OF
THE WEEK
 24h or  HOUR  MINUTE
12h
 Press reset button.
All data is deleted after a reset and the device is returned Select digit for day of the week: Presetting e.g.
to factory settings (not preset). Monday = 1; depending on country: Sunday = 1, Saturday = 1
1
6. Switching times PROG
7.2 Set free rule (FREE)
1. Change to summer time
6.1 Set switching times
 E nter month, week in month (5 = last week), day of the
memory location week, changeover time consecutively
PROG  C1/C2*  1 C1  1 C1 On  HOURS
OK OK OK OK
– – : -- – – – : -- – 2. Change to winter time
 Enter month, week in month
 MINUTES  WEEK Selection of days of the week/blocks:
OK OK

DAYS
Days 1-7; 1-5; 6-7; 1-6; or all days individually
8. Set manual permanent switching
 2 C1
The permanent switching (PERMANENT ON, PERMANENT

OK
– – : -- – set additional switching time
OFF) can be selected for each channel via direct operation
of buttons.
+ END
OK
 C1 Off
* only with BZT28372
PROG TIME DATE SU/ WI
11:28  BZT28371: Press
12 31 + and – buttons simultaneously
( appears)
There are 28 available memory locations per channel. BZT28372: AMC1: Press + and – buttons
for
PM
for C2: Press + and OK buttons
6.2 Request switching times 
ESC - OK
Press button continually until the required status is displayed

Res  1  2
Request switching times by using + or – buttons.
 (PERMANENT ON, PERMANENT OFF, no permanent
switching).

6.3 Change /delete switching times


Change switching times:
9. Technical data
 Confirm stored switching time by pressing the OK button. • Rated voltage: 220­–230 V~
+10 %/-15 %
 Press OK button again once, use + or – button to change
 • Frequency: 50–60 Hz
hour/minute. • Power consumption: typically 4,5 VA
 Confirm with OK button. • Contact: floating
• Contact material: AgSnO2
Delete switching time: • Switching capacity: 16 (6) A, 250 V~
• Power reserve: 6 years at 20 °C
 Confirm stored switching time by pressing the OK button.
 Press + or – button; it appears 1 C1 On • Incandescent lamp load: 1400 W
 Confirm with OK button. – – : -- – • Halogen lamp load: 1400 W
1234567
• Fluorescent lamp
uncorrected: 1400 VA
series-corrected: 1400 VA
parallel-corrected: 220 VA (24mF)
7. Summer/winter time SU/ WI
• Compact fluorescent 13 x 7 W, 13 x 11 W,
tubes: 10 x 15 W, 8 x 23 W
7.1 Set summer/winter time • Permissible ambient-
temperature: –20 °C ... +55 °C
Press ESC button and using the + or – buttons select

 • Protection class: II in accordance with IEC/EN 60730-1
SU/WI menu. with designated installation
Press OK button and using the + or – buttons select

 • Degree of protection: IP 20 in accordance with IEC/EN 60529
the relevant rule (see table).
ESC

SU/ WI
Summer/winter time rules

– – – –
no rule
– – -- – EU rule for the EU
USA USA
EU  C1 On
OK CDN Canada
11:28 IL Israel
USA
NZ New Zealand
IRAN Iran
FREE free rule
 ...

DATE fixed date Schrack Technik GmbH


2 www.schrack.com