Professional Documents
Culture Documents
2 SSA-PRC008-E4
Features and Benefits
SSA-PRC008-E4 3
Features and Benefits
4 SSA-PRC008-E4
Contents
SSA-PRC008-E4 5
System performance matrix
6 SSA-PRC008-E4
Model nomenclature
Indoor Unit
4 M W D 0 5 1 2 A B 0 R 0 A A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
SSA-PRC008-E4 7
Model nomenclature
Outdoor Unit
4 T W K 0 5 1 2 A B 0 0 0 A A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Digit #1 = Refrigerant Digit #5 = Efficiency Tier Digit #11 = Factory Supplier Options
4 = R410A 0 = Standard efficiency 0 = Standard
2 = R22 2 = 12 SEER P = With piping kit
3 = 13 SEER or European “A” Class
Digit #2 = Brand Digit #12 = Number of Refrigerant Ports
5 = 14.5+ SEER
T = Trane 0 = Standard (single port)
6 = 16 SEER
A = American Standard 2 = Dual Ports
8 = 18 SEER
R = Ingersoll Rand 3 = Triple Ports
Digit #6 = Connection type 4 = Quadruple Ports
Digit #3 = Function Type
5 = Flare Connection
X = Heat Pump DC Inverter, Single Digit #13 = Coil Fin Protection
0 = Sweat (Brazed)
Y = Cooling Only DC Inverter, Single 0 = Standard
W = Heat Pump Fixed Speed, Single Digit #7, 8 = Nominal Capacity C = Corrosion Resistant
(BTU/h x 1,000)
T = Cooling Only Fixed Speed, Single
09 = 9,000 BTU/h 30 = 30,000 BTU/h
Digit #14 = Matching Outdoor
M = Heat Pump DC Inverter Multi-split 12 = 12,000 BTU/h 36 = 36,000 BTU/h A = High Wall
N = Cooling Only DC Inverter Multi-split 18 = 18,000 BTU/h 42 = 42,000 BTU/h
24 = 24,000 BTU/h 48 = 48,000 BTU/h C = Cassette
E = Heat Pump Fixed Speed Multi-split 28 = 28,000 BTU/h 60 = 60,000 BTU/h
D = Ducted
F = Cooling Only Fixed Speed Multi-split Digit #9 = Major Development Sequence V = Tall Floor
A = Window units A = First Development Sequence X = Convertible
Digit #4 = Configuration Outdoor Unit B = Second Development Sequence
Digit #15 = Minor Design Sequence
K = Single Refrigerant Circuit, Horizontal C = Third Development Sequence
Discharge A = First Sequence
Digit #10 = Electric Power Supply B = Second Sequence
D = Dual Refrigerant Circuit, Horizontal Characteristics
Discharge
1 = 220/60/1
T = Triple Refrigerant Circuit, Horizontal
Discharge 3 = 208-230/60/3
Q = Quadruple Refrigerant Circuit, 4 = 460/60/3
Horizontal Discharge 6 = 220/60/3
M = Single Refrigerant Circuit, 9 = 115/60/1
Horizontal Discharge, Multi Ports B = 220-240/50/1
C = 380/50/3
D = 380-415/50/3
K = 380/60/3
8 SSA-PRC008-E4
General data
Outdoor unit model 4TWK0512AB 4TWK0518AB 4TWK0524AB 4TWK0530AB 4TWK0530AD 4TWK0536AB 4TWK0536AD 4TWK0548AD 4TWK0560AD
Performance data
Nominal capacity1 (Btu/h) 11,400 19,200 25,500 30,100 31,000 36,700 36,600 46,800 53,800
Nominal capacity1 (kW) 3.34 5.62 7.46 8.81 9.1 10.75 10.72 13.70 15.75
Total system power input (W) 1,300 2,300 3,000 3,800 3,700 4,700 4,400 5,700 6,800
System current (A) 5.86 12.01 14.17 17.50 6.24 21.88 7.54 9.39 11.38
Heating nominal capacity1 (Btu/h) 12,900 20,500 25,600 32,900 32,000 41,000 40,100 49,000 55,700
Total system power input (W) 1,300 1,900 2,700 3,500 3,100 4,000 3,800 4,800 5,600
System current (A) 5.90 8.87 12.77 15.91 5.25 19.19 6.82 8.20 9.36
Indoor units
227 / 142 227 / 142 291 / 168 291 / 168 356 / 201 355 / 223
Fan motor power input (W) 69 / 54 / 48 107 / 65 / 52 163 / 93 / 75
/ 115 / 115 / 138 / 138 / 152 / 173
470 / 360 690 / 450 820 / 650 1,300 / 1,110 1,300 / 1,110 1,300 / 1,100 1,300 / 1,100 1,800/ 1,400 / 1,900 / 1,500 /
Air flow (H /M /L) (CFM)
/ 300 / 380 / 590 / 970 / 970 / 970 / 970 1,100 1,200
210 x 700 210 x 920 270 x 920 270 x 1,140 270 x 1,140 270 x 1,140 270 x 1,140 300 x 1,200 300 x 1,200
Dimensions (H/W/D) (mm)
x 635 x 635 x 635 x 775 x 775 x 775 x 775 x 865 x 865
Outdoor Units
Compressor rated power input (W) 1,150 / 58 1,855 / 110 2,430 / 168.7 3,750 / 290 3,650 / 290 3,750 / 290 3,650 / 290 4,750 / 171 5,750 / 148
Compressor rated current (A) 5.15 8.70 11.40 18.10 6.58 18.10 6.58 8.22 9.77
Expansion device type Capillary Capillary Capillary Capillary Capillary Capillary Capillary Capillary Capillary
Compressor type Rotary Rotary Rotary Scroll Scroll Scroll Scroll Rotary Scroll
Fan motor speed (RPM) 800 890 900 840 840 840 840 825 800
Fan type number Axial-1 Axial-1 Axial-1 Axial-1 Axial-1 Axial-1 Axial-1 Axial-2 Axial-2
547 x 780 593 x 762 695 x 842 966 x 990 966 x 990 966 x 990 966 x 990 1,167 x 900 1,167 x 900
Dimensions (H/W/D) (mm)
x 250 x 282 x 324 x 354 x 354 x 354 x 354 x 340 x 340
Refrigerant pipe size - liquid (inch) 1/4” 1/4” 3/8” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
Refrigerant pipe size - suction (inch) 1/2” 1/2” 5/8” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
R410A Refrigerant Charge (kg) 1.12 1.40 1.90 3.10 3.10 2.90 2.90 3.25 3.20
1
Performance Capacity @ ARI Conditions 35°C Ambient 27°C DB & 19°C WB
1
Performance Capacity @ ARI Conditions 95°F Ambient 80°F DB & 67°F WB
2
Sound data @ distance of 1 Meter from source
SSA-PRC008-E4 9
Fan performance data
60K Btu/h
External static pressure (Pa)
SSA-PRC008-E4 11
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 3.16 3.01 2.86 2.70 2.67
21 / 15ºC DB/WB SC 2.25 2.23 2.20 2.25 2.19
Input 0.85 0.93 0.97 1.00 1.01
TC 3.26 3.10 2.95 2.76 2.70
24 / 17ºC DB/WB SC 2.34 2.33 2.30 2.34 2.22
Input 0.90 0.97 1.01 1.06 1.08
TC 3.32 3.16 3.07 2.86 2.76
27 / 19ºC DB/WB SC 2.36 2.34 2.30 2.36 2.21
Input 0.93 0.36 1.03 1.08 1.10
TC 3.38 3.26 3.19 2.95 2.86
32 / 23ºC DB/WB SC 2.77 2.74 2.72 2.77 2.63
Input 0.97 1.01 1.08 1.12 1.13
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 3.03 2.89 2.74 2.62 2.56
21 / 15ºC DB/WB SC 2.06 2.05 2.03 2.06 2.02
Input 0.82 0.89 0.93 0.96 0.97
TC 3.12 2.97 2.83 2.65 2.59
24 / 17ºC DB/WB SC 2.15 2.14 2.12 2.15 2.05
Input 0.87 0.93 0.97 1.02 1.04
TC 3.18 3.03 2.94 2.74 2.65
27 / 19ºC DB/WB SC 2.16 2.15 2.13 2.16 2.04
Input 0.89 0.35 0.99 1.04 1.05
TC 3.24 3.15 3.06 2.83 2.74
32 / 23ºC DB/WB SC 2.56 2.55 2.51 2.56 2.44
Input 0.93 0.97 1.04 1.07 1.08
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
12 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 10.78 10.25 9.73 9.21 9.10
69.8 / 59ºF DB/WB SC (KBtu) 7.65 7.59 7.49 7.46 7.47
Input (kW) 0.85 0.93 0.97 1.00 1.01
TC (KBtu) 11.09 10.57 10.05 9.42 9.21
75.2 / 62ºF DB/WB SC (KBtu) 7.99 7.93 7.84 7.63 7.55
Input (kW) 0.90 0.97 1.01 1.06 1.08
TC (KBtu) 11.30 10.78 10.46 9.73 9.42
80.6 / 66.2ºF DB/WB SC (KBtu) 8.02 7.98 7.85 7.69 7.53
Input (kW) 0.93 0.98 1.03 1.08 1.10
TC (KBtu) 11.51 11.09 10.88 10.05 9.73
89.6 / 73.4ºF DB/WB SC (KBtu) 9.44 9.32 9.25 9.04 8.95
Input (kW) 0.97 1.01 1.08 1.12 1.13
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 10.33 9.83 9.33 8.92 8.72
69.8 / 59ºF DB/WB SC (KBtu) 7.02 6.98 6.90 6.96 6.89
Input (kW) 0.82 0.89 0.93 0.96 0.97
TC (KBtu) 10.63 10.13 9.63 9.03 8.82
75.2 / 62ºF DB/WB SC (KBtu) 7.33 7.29 7.22 7.04 6.97
Input (kW) 0.87 0.93 0.97 1.02 1.04
TC (KBtu) 10.83 10.33 10.03 9.33 9.03
80.6 / 66.2ºF DB/WB SC (KBtu) 7.36 7.33 7.27 7.09 6.95
Input (kW) 0.89 0.94 0.99 1.04 1.05
TC (KBtu) 11.03 10.73 10.43 9.63 9.33
89.6 / 73.4ºF DB/WB SC (KBtu) 8.71 8.69 8.55 8.38 8.30
Input (kW) 0.93 0.97 1.04 1.07 1.08
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 13
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 5.24 4.99 4.73 4.48 4.43
21 / 15ºC DB/WB SC 3.72 3.69 3.64 3.63 3.63
Input 1.41 1.53 1.60 1.65 1.67
TC 5.39 5.14 4.88 4.58 4.48
24 / 17ºC DB/WB SC 3.88 3.85 3.81 3.71 3.67
Input 1.50 1.60 1.67 1.75 1.79
TC 5.50 5.24 5.09 4.73 4.58
27 / 19ºC DB/WB SC 3.90 3.88 3.82 3.74 3.66
Input 1.53 0.60 1.70 1.79 1.82
TC 5.60 5.39 5.29 4.88 4.73
32 / 23ºC DB/WB SC 4.59 4.53 4.50 4.40 4.35
Input 1.60 1.67 1.79 1.86 1.87
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 5.02 4.78 4.53 4.34 4.24
21 / 15ºC DB/WB SC 3.42 3.39 3.36 3.38 3.35
Input 1.35 1.47 1.53 1.58 1.60
TC 5.17 4.92 4.68 4.39 4.29
24 / 17ºC DB/WB SC 3.57 3.55 3.51 3.42 3.39
Input 1.44 1.53 1.60 1.68 1.71
TC 5.27 5.02 4.88 4.53 4.39
27 / 19ºC DB/WB SC 3.58 3.57 3.54 3.45 3.38
Input 1.47 0.57 1.63 1.71 1.75
TC 5.36 5.22 5.07 4.68 4.53
32 / 23ºC DB/WB SC 4.24 4.23 4.16 4.07 4.04
Input 1.53 1.60 1.71 1.78 1.80
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
14 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 17.88 17.01 16.14 15.27 15.10
69.8 / 59ºF DB/WB SC (KBtu) 12.69 12.59 12.43 12.37 12.38
Input (kW) 1.42 1.54 1.60 1.66 1.67
TC (KBtu) 18.40 17.53 16.66 15.62 15.27
75.2 / 62ºF DB/WB SC (KBtu) 13.25 13.15 13.00 12.65 12.52
Input (kW) 1.50 1.60 1.67 1.76 1.79
TC (KBtu) 18.75 17.88 17.36 16.14 15.62
80.6 / 66.2ºF DB/WB SC (KBtu) 13.31 13.23 13.02 12.75 12.50
Input (kW) 1.54 1.62 1.71 1.79 1.83
TC (KBtu) 19.09 18.40 18.05 16.66 16.14
89.6 / 73.4ºF DB/WB SC (KBtu) 15.66 15.45 15.34 15.00 14.85
Input (kW) 1.60 1.67 1.79 1.86 1.88
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 17.13 16.30 15.47 14.80 14.47
69.8 / 59ºF DB/WB SC (KBtu) 11.65 11.57 11.45 11.55 11.43
Input (kW) 1.36 1.47 1.54 1.59 1.60
TC (KBtu) 17.63 16.80 15.97 14.97 14.64
75.2 / 62ºF DB/WB SC (KBtu) 12.17 12.10 11.98 11.68 11.56
Input (kW) 1.44 1.54 1.60 1.69 1.72
TC (KBtu) 17.96 17.13 16.63 15.47 14.97
80.6 / 66.2ºF DB/WB SC (KBtu) 12.22 12.16 12.06 11.76 11.53
Input (kW) 1.47 1.55 1.64 1.72 1.75
TC (KBtu) 18.30 17.80 17.30 15.97 15.47
89.6 / 73.4ºF DB/WB SC (KBtu) 14.45 14.42 14.19 13.89 13.77
Input (kW) 1.54 1.60 1.72 1.78 1.80
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 15
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 7.02 6.68 6.34 6.00 5.93
21 / 15ºC DB/WB SC 4.98 4.94 4.88 4.86 4.86
Input 1.94 2.11 2.20 2.27 2.30
TC 7.22 6.88 6.54 6.13 6.00
24 / 17ºC DB/WB SC 5.20 5.16 5.10 4.97 4.92
Input 2.06 2.20 2.30 2.41 2.46
TC 7.36 7.02 6.82 6.34 6.13
27 / 19ºC DB/WB SC 5.23 5.20 5.11 5.01 4.91
Input 2.11 0.82 2.34 2.46 2.51
TC 7.50 7.22 7.09 6.54 6.34
32 / 23ºC DB/WB SC 6.15 6.07 6.03 5.89 5.83
Input 2.20 2.30 2.46 2.55 2.58
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 6.73 6.40 6.07 5.81 5.68
21 / 15ºC DB/WB SC 4.58 4.54 4.50 4.53 4.49
Input 1.86 2.02 2.11 2.18 2.20
TC 6.92 6.60 6.27 5.88 5.75
24 / 17ºC DB/WB SC 4.78 4.75 4.70 4.59 4.54
Input 1.98 2.11 2.20 2.31 2.36
TC 7.05 6.73 6.53 6.07 5.88
27 / 19ºC DB/WB SC 4.80 4.78 4.74 4.62 4.53
Input 2.02 0.79 2.25 2.36 2.40
TC 7.19 6.99 6.79 6.27 6.07
32 / 23ºC DB/WB SC 5.68 5.66 5.57 5.46 5.41
Input 2.11 2.20 2.36 2.45 2.47
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
16 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 23.96 22.80 21.63 20.47 20.24
69.8 / 59ºF DB/WB SC (KBtu) 17.01 16.87 16.66 16.58 16.59
Input (kW) 1.95 2.11 2.21 2.28 2.30
TC (KBtu) 24.66 23.49 22.33 20.93 20.47
75.2 / 62ºF DB/WB SC (KBtu) 17.75 17.62 17.42 16.96 16.78
Input (kW) 2.07 2.21 2.30 2.42 2.46
TC (KBtu) 25.12 23.96 23.26 21.63 20.93
80.6 / 66.2ºF DB/WB SC (KBtu) 17.84 17.73 17.45 17.09 16.75
Input (kW) 2.11 2.23 2.35 2.46 2.51
TC (KBtu) 25.59 24.66 24.19 22.33 21.63
89.6 / 73.4ºF DB/WB SC (KBtu) 20.98 20.71 20.56 20.10 19.90
Input (kW) 2.21 2.30 2.46 2.56 2.58
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 22.96 21.85 20.73 19.84 19.39
69.8 / 59ºF DB/WB SC (KBtu) 15.61 15.51 15.34 15.47 15.32
Input (kW) 1.87 2.03 2.12 2.18 2.21
TC (KBtu) 23.63 22.51 21.40 20.06 19.62
75.2 / 62ºF DB/WB SC (KBtu) 16.30 16.21 16.05 15.65 15.50
Input (kW) 1.98 2.12 2.21 2.32 2.36
TC (KBtu) 24.07 22.96 22.29 20.73 20.06
80.6 / 66.2ºF DB/WB SC (KBtu) 16.37 16.30 16.16 15.76 15.45
Input (kW) 2.03 2.14 2.25 2.36 2.41
TC (KBtu) 24.52 23.85 23.18 21.40 20.73
89.6 / 73.4ºF DB/WB SC (KBtu) 19.37 19.32 19.01 18.62 18.45
Input (kW) 2.12 2.21 2.36 2.45 2.48
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 17
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 8.90 8.47 8.04 7.60 7.52
21 / 15ºC DB/WB SC 6.32 6.27 6.19 6.16 6.16
Input 2.55 2.77 2.89 2.98 3.01
TC 9.16 8.73 8.29 7.78 7.60
24 / 17ºC DB/WB SC 6.59 6.54 6.47 6.30 6.23
Input 2.71 2.89 3.01 3.17 3.23
TC 9.33 8.90 8.64 8.04 7.78
27 / 19ºC DB/WB SC 6.63 6.59 6.48 6.35 6.22
Input 2.77 1.08 3.07 3.23 3.29
TC 9.50 9.16 8.99 8.29 8.04
32 / 23ºC DB/WB SC 7.79 7.69 7.64 7.46 7.39
Input 2.89 3.01 3.23 3.35 3.38
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 8.53 8.11 7.70 7.37 7.20
21 / 15ºC DB/WB SC 5.80 5.76 5.70 5.75 5.69
Input 2.45 2.65 2.77 2.86 2.89
TC 8.78 8.36 7.95 7.45 7.29
24 / 17ºC DB/WB SC 6.06 6.02 5.96 5.81 5.76
Input 2.59 2.77 2.89 3.04 3.09
TC 8.94 8.53 8.28 7.70 7.45
27 / 19ºC DB/WB SC 6.08 6.06 6.00 5.85 5.74
Input 2.65 1.03 2.95 3.09 3.15
TC 9.11 8.86 8.61 7.95 7.70
32 / 23ºC DB/WB SC 7.20 7.18 7.06 6.92 6.85
Input 2.77 2.89 3.09 3.21 3.24
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
18 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 30.37 28.89 27.42 25.94 25.65
69.8 / 59ºF DB/WB SC (KBtu) 21.56 21.38 21.11 21.01 21.03
Input (kW) 2.55 2.77 2.89 2.98 3.01
TC (KBtu) 31.25 29.78 28.30 26.53 25.94
75.2 / 62ºF DB/WB SC (KBtu) 22.50 22.33 22.08 21.49 21.27
Input (kW) 2.71 2.89 3.01 3.17 3.23
TC (KBtu) 31.84 30.37 29.48 27.42 26.53
80.6 / 66.2ºF DB/WB SC (KBtu) 22.61 22.47 22.11 21.66 21.23
Input (kW) 2.77 2.92 3.07 3.23 3.29
TC (KBtu) 32.43 31.25 30.66 28.30 27.42
89.6 / 73.4ºF DB/WB SC (KBtu) 26.59 26.25 26.06 25.47 25.22
Input (kW) 2.89 3.01 3.23 3.35 3.38
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 29.10 27.69 26.28 25.15 24.58
69.8 / 59ºF DB/WB SC (KBtu) 19.79 19.66 19.44 19.61 19.42
Input (kW) 2.45 2.65 2.77 2.86 2.89
TC (KBtu) 29.95 28.54 27.12 25.43 24.86
75.2 / 62ºF DB/WB SC (KBtu) 20.66 20.55 20.34 19.83 19.64
Input (kW) 2.59 2.77 2.89 3.04 3.10
TC (KBtu) 30.51 29.10 28.25 26.28 25.43
80.6 / 66.2ºF DB/WB SC (KBtu) 20.75 20.66 20.48 19.97 19.58
Input (kW) 2.65 2.80 2.95 3.10 3.15
TC (KBtu) 31.08 30.23 29.38 27.12 26.28
89.6 / 73.4ºF DB/WB SC (KBtu) 24.55 24.49 24.09 23.60 23.39
Input (kW) 2.77 2.89 3.10 3.21 3.24
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 19
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 10.38 9.88 9.37 8.87 8.77
21 / 15ºC DB/WB SC 7.37 7.31 7.22 7.19 7.19
Input 3.01 3.26 3.41 3.52 3.55
TC 10.68 10.18 9.68 9.07 8.87
24 / 17ºC DB/WB SC 7.69 7.64 7.55 7.35 7.27
Input 3.19 3.41 3.55 3.73 3.81
TC 10.89 10.38 10.08 9.37 9.07
27 / 19ºC DB/WB SC 7.73 7.68 7.56 7.41 7.26
Input 3.26 1.27 3.62 3.81 3.88
TC 11.09 10.68 10.48 9.68 9.37
32 / 23ºC DB/WB SC 9.09 8.98 8.91 8.71 8.62
Input 3.41 3.55 3.81 3.95 3.99
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 9.95 9.47 8.98 8.60 8.40
21 / 15ºC DB/WB SC 6.77 6.72 6.65 6.71 6.64
Input 2.88 3.13 3.27 3.37 3.41
TC 10.24 9.76 9.27 8.69 8.50
24 / 17ºC DB/WB SC 7.07 7.02 6.96 6.78 6.72
Input 3.06 3.27 3.41 3.58 3.65
TC 10.43 9.95 9.66 8.98 8.69
27 / 19ºC DB/WB SC 7.09 7.06 7.00 6.83 6.69
Input 3.13 1.22 3.48 3.65 3.72
TC 10.63 10.34 10.05 9.27 8.98
32 / 23ºC DB/WB SC 8.39 8.37 8.24 8.07 8.00
Input 3.27 3.41 3.65 3.79 3.82
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
20 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 35.43 33.71 31.99 30.27 29.93
69.8 / 59ºF DB/WB SC (KBtu) 25.15 24.94 24.63 24.52 24.54
Input (kW) 3.01 3.27 3.41 3.52 3.56
TC (KBtu) 36.46 34.74 33.02 30.96 30.27
75.2 / 62ºF DB/WB SC (KBtu) 26.25 26.06 25.76 25.08 24.82
Input (kW) 3.19 3.41 3.56 3.74 3.81
TC (KBtu) 37.15 35.43 34.40 31.99 30.96
80.6 / 66.2ºF DB/WB SC (KBtu) 26.38 26.22 25.80 25.27 24.77
Input (kW) 3.27 3.45 3.63 3.81 3.88
TC (KBtu) 37.84 36.46 35.77 33.02 31.99
89.6 / 73.4ºF DB/WB SC (KBtu) 31.03 30.63 30.41 29.72 29.43
Input (kW) 3.41 3.56 3.81 3.95 3.99
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 33.95 32.30 30.66 29.34 28.68
69.8 / 59ºF DB/WB SC (KBtu) 23.09 22.94 22.69 22.88 22.66
Input (kW) 2.89 3.13 3.27 3.37 3.41
TC (KBtu) 34.94 33.29 31.65 29.67 29.01
75.2 / 62ºF DB/WB SC (KBtu) 24.11 23.97 23.73 23.14 22.92
Input (kW) 3.06 3.27 3.41 3.58 3.65
TC (KBtu) 35.60 33.95 32.96 30.66 29.67
80.6 / 66.2ºF DB/WB SC (KBtu) 24.21 24.11 23.90 23.30 22.84
Input (kW) 3.13 3.30 3.48 3.65 3.72
TC (KBtu) 36.26 35.27 34.28 31.65 30.66
89.6 / 73.4ºF DB/WB SC (KBtu) 28.65 28.57 28.11 27.53 27.28
Input (kW) 3.27 3.41 3.65 3.79 3.83
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 21
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 13.84 13.17 12.50 11.83 11.69
21 / 15ºC DB/WB SC 9.83 9.75 9.62 9.58 9.59
Input 4.11 4.46 4.66 4.81 4.86
TC 14.25 13.57 12.90 12.10 11.83
24 / 17ºC DB/WB SC 10.26 10.18 10.06 9.80 9.70
Input 4.36 4.66 4.86 5.10 5.20
TC 14.52 13.84 13.44 12.50 12.10
27 / 19ºC DB/WB SC 10.31 10.24 10.08 9.87 9.68
Input 4.46 1.73 4.96 5.20 5.30
TC 14.78 14.25 13.98 12.90 12.50
32 / 23ºC DB/WB SC 12.12 11.97 11.88 11.61 11.50
Input 4.66 4.86 5.20 5.40 5.45
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 13.27 12.62 11.98 11.46 11.21
21 / 15ºC DB/WB SC 9.02 8.96 8.86 8.94 8.85
Input 3.94 4.28 4.47 4.61 4.66
TC 13.65 13.01 12.36 11.59 11.33
24 / 17ºC DB/WB SC 9.42 9.37 9.27 9.04 8.95
Input 4.18 4.47 4.66 4.89 4.99
TC 13.91 13.27 12.88 11.98 11.59
27 / 19ºC DB/WB SC 9.46 9.42 9.34 9.10 8.93
Input 4.28 1.66 4.75 4.99 5.08
TC 14.17 13.78 13.40 12.36 11.98
32 / 23ºC DB/WB SC 11.19 11.16 10.98 10.76 10.66
Input 4.47 4.66 4.99 5.18 5.23
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
22 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 47.23 44.94 42.65 40.36 39.90
69.8 / 59ºF DB/WB SC (KBtu) 33.54 33.26 32.84 32.69 32.72
Input (kW) 4.11 4.46 4.66 4.81 4.86
TC (KBtu) 48.61 46.32 44.02 41.27 40.36
75.2 / 62ºF DB/WB SC (KBtu) 35.00 34.74 34.34 33.43 33.09
Input (kW) 4.36 4.66 4.86 5.11 5.20
TC (KBtu) 49.53 47.23 45.86 42.65 41.27
80.6 / 66.2ºF DB/WB SC (KBtu) 35.16 34.95 34.39 33.69 33.02
Input (kW) 4.46 4.71 4.96 5.20 5.30
TC (KBtu) 50.45 48.61 47.69 44.02 42.65
89.6 / 73.4ºF DB/WB SC (KBtu) 41.36 40.83 40.54 39.62 39.24
Input (kW) 4.66 4.86 5.20 5.40 5.45
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 45.27 43.07 40.87 39.11 38.24
69.8 / 59ºF DB/WB SC (KBtu) 30.78 30.58 30.25 30.51 30.21
Input (kW) 3.94 4.28 4.47 4.61 4.66
TC (KBtu) 46.59 44.39 42.19 39.55 38.67
75.2 / 62ºF DB/WB SC (KBtu) 32.14 31.96 31.64 30.85 30.55
Input (kW) 4.18 4.47 4.66 4.89 4.99
TC (KBtu) 47.46 45.27 43.95 40.87 39.55
80.6 / 66.2ºF DB/WB SC (KBtu) 32.28 32.14 31.86 31.06 30.46
Input (kW) 4.28 4.51 4.75 4.99 5.08
TC (KBtu) 48.34 47.02 45.71 42.19 40.87
89.6 / 73.4ºF DB/WB SC (KBtu) 38.19 38.09 37.48 36.71 36.38
Input (kW) 4.47 4.66 4.99 5.18 5.23
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 23
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 15.82 15.05 14.28 13.67 13.36
21 / 15ºC DB/WB SC 11.23 11.14 11.00 10.95 10.96
Input 4.72 5.12 5.34 5.51 5.57
TC 16.28 15.51 14.75 13.82 13.52
24 / 17ºC DB/WB SC 11.72 11.64 11.50 11.20 11.08
Input 5.00 5.34 5.57 5.86 5.97
TC 16.59 15.82 15.36 14.28 13.82
27 / 19ºC DB/WB SC 11.78 11.71 11.52 11.28 11.06
Input 5.12 1.99 5.69 5.97 6.08
TC 16.90 16.28 15.97 14.75 14.28
32 / 23ºC DB/WB SC 13.85 13.68 13.58 13.27 13.14
Input 5.34 5.57 5.97 6.20 6.25
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 46ºC
TC 15.16 14.43 13.69 13.10 12.81
21 / 15ºC DB/WB SC 10.31 10.24 10.13 10.22 10.12
Input 4.52 4.91 5.12 5.29 5.34
TC 15.60 14.87 14.13 13.25 12.95
24 / 17ºC DB/WB SC 10.77 10.70 10.60 10.33 10.23
Input 4.80 5.12 5.34 5.61 5.72
TC 15.90 15.16 14.72 13.69 13.25
27 / 19ºC DB/WB SC 10.81 10.76 10.67 10.40 10.20
Input 4.91 1.91 5.45 5.72 5.83
TC 16.19 15.75 15.31 14.13 13.69
32 / 23ºC DB/WB SC 12.79 12.76 12.55 12.29 12.18
Input 5.12 5.34 5.72 5.94 6.00
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
24 SSA-PRC008-E4
System performance data
Medium speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 53.99 51.37 48.75 46.13 45.60
69.8 / 59ºF DB/WB SC (KBtu) 38.33 38.01 37.54 37.36 37.39
Input (kW) 4.72 5.12 5.34 5.51 5.57
TC (KBtu) 55.56 52.94 50.32 47.17 46.13
75.2 / 62ºF DB/WB SC (KBtu) 40.00 39.71 39.25 38.21 37.82
Input (kW) 5.00 5.34 5.57 5.85 5.97
TC (KBtu) 56.61 53.99 52.42 48.75 47.17
80.6 / 66.2ºF DB/WB SC (KBtu) 40.19 39.95 39.31 38.51 37.74
Input (kW) 5.12 5.40 5.68 5.97 6.08
TC (KBtu) 57.66 55.56 54.51 50.32 48.75
89.6 / 73.4ºF DB/WB SC (KBtu) 47.28 46.67 46.34 45.29 44.85
Input (kW) 5.34 5.57 5.97 6.20 6.25
Low speed
Cooling Outdoor conditions (DB) at 0Pa
Indoor Conditions 69.8ºF 82.4ºF 95ºF 109.4ºF 115ºF
TC (KBtu) 51.74 49.23 46.72 44.71 43.70
69.8 / 59ºF DB/WB SC (KBtu) 35.18 34.95 34.57 34.87 34.52
Input (kW) 4.52 4.90 5.12 5.29 5.34
TC (KBtu) 53.25 50.73 48.22 45.21 44.20
75.2 / 62ºF DB/WB SC (KBtu) 36.74 36.53 36.17 35.26 34.92
Input (kW) 4.80 5.12 5.34 5.61 5.72
TC (KBtu) 54.25 51.74 50.23 46.72 45.21
80.6 / 66.2ºF DB/WB SC (KBtu) 36.89 36.73 36.42 35.50 34.81
Input (kW) 4.90 5.18 5.45 5.72 5.83
TC (KBtu) 55.26 53.75 52.24 48.22 46.72
89.6 / 73.4ºF DB/WB SC (KBtu) 43.65 43.54 42.84 41.95 41.58
Input (kW) 5.12 5.34 5.72 5.94 5.99
Note:
TC: Total capacity
SC: Sensible heat capacity
Input: Input power
SSA-PRC008-E4 25
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 4.94 3.99 3.27 2.96 2.77
15ºC
Input 1.26 1.08 0.93 0.87 0.83
TC 4.79 3.80 3.08 2.89 2.66
20ºC
Input 1.37 1.16 1.02 0.94 0.88
TC 4.48 3.57 2.89 2.81 2.51
27ºC
Input 1.45 1.26 1.11 1.02 0.95
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 4.73 3.82 3.13 2.84 2.66
15ºC
Input 1.20 1.04 0.89 0.84 0.79
TC 4.59 3.64 2.95 2.77 2.55
20ºC
Input 1.32 1.12 0.98 0.90 0.85
TC 4.30 3.42 2.77 2.69 2.40
27ºC
Input 1.39 1.20 1.06 0.98 0.91
Note:
TC: Total capacity
Input: Input power
26 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 16.85 13.61 11.14 10.11 9.46
59ºF
Input (kW) 1.26 1.08 0.93 0.87 0.83
TC (KBtu) 16.33 12.96 10.50 9.85 9.07
68ºF
Input (kW) 1.37 1.16 1.02 0.94 0.88
TC (KBtu) 15.29 12.18 9.85 9.59 8.55
80.6ºF
Input (kW) 1.45 1.26 1.11 1.02 0.95
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 16.14 13.03 10.67 9.68 9.06
59ºF
Input (kW) 1.20 1.04 0.89 0.84 0.79
TC (KBtu) 15.64 12.41 10.05 9.43 8.69
68ºF
Input (kW) 1.32 1.12 0.98 0.90 0.85
TC (KBtu) 14.65 11.67 9.43 9.19 8.19
80.6ºF
Input (kW) 1.39 1.20 1.06 0.98 0.91
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 27
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 7.41 5.99 4.90 4.45 4.16
15ºC
Input 1.94 1.67 1.44 1.35 1.28
TC 7.18 5.70 4.62 4.33 3.99
20ºC
Input 2.12 1.80 1.58 1.46 1.37
TC 6.73 5.36 4.33 4.22 3.76
27ºC
Input 2.25 1.94 1.71 1.58 1.48
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 7.10 5.73 4.70 4.26 3.99
15ºC
Input 1.86 1.60 1.38 1.29 1.22
TC 6.88 5.46 4.42 4.15 3.82
20ºC
Input 2.04 1.73 1.52 1.40 1.31
TC 6.44 5.13 4.15 4.04 3.60
27ºC
Input 2.16 1.84 1.62 1.50 1.40
Note:
TC: Total capacity
Input: Input power
28 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 25.28 20.42 16.72 15.17 14.20
59ºF
Input (kW) 1.95 1.68 1.44 1.35 1.28
TC (KBtu) 24.50 19.45 15.75 14.78 13.61
68ºF
Input (kW) 2.13 1.80 1.59 1.46 1.37
TC (KBtu) 22.95 18.28 14.78 14.39 12.83
80.6ºF
Input (kW) 2.26 1.95 1.71 1.59 1.48
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 24.22 19.56 16.02 14.53 13.60
59ºF
Input (kW) 1.87 1.61 1.38 1.30 1.23
TC (KBtu) 23.47 18.63 15.09 14.16 13.04
68ºF
Input (kW) 2.04 1.73 1.52 1.40 1.31
TC (KBtu) 21.98 17.51 14.16 13.78 12.29
80.6ºF
Input (kW) 2.16 1.87 1.64 1.52 1.42
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 29
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 9.39 7.58 6.21 5.63 5.27
15ºC
Input 2.51 2.16 1.86 1.74 1.65
TC 9.10 7.22 5.85 5.49 5.05
20ºC
Input 2.74 2.32 2.04 1.88 1.77
TC 8.52 6.79 5.49 5.34 4.77
27ºC
Input 2.90 2.51 2.21 2.04 1.91
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 8.99 7.26 5.95 5.39 5.05
15ºC
Input 2.40 2.07 1.78 1.67 1.58
Note:
TC: Total capacity
Input: Input power
30 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 32.02 25.87 21.18 19.21 17.98
59ºF
Input (kW) 2.51 2.16 1.86 1.74 1.65
TC (KBtu) 31.04 24.63 19.95 18.72 17.24
68ºF
Input (kW) 2.74 2.32 2.04 1.88 1.77
TC (KBtu) 29.07 23.16 18.72 18.23 16.26
80.6ºF
Input (kW) 2.90 2.51 2.21 2.04 1.91
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 30.68 24.78 20.29 18.41 17.23
59ºF
Input (kW) 2.40 2.07 1.78 1.67 1.58
TC (KBtu) 29.73 23.60 19.11 17.93 16.52
68ºF
Input (kW) 2.63 2.23 1.96 1.80 1.69
TC (KBtu) 27.84 22.18 17.93 17.46 15.57
80.6ºF
Input (kW) 2.78 2.40 2.12 1.96 1.83
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 31
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 11.61 9.38 7.68 6.97 6.52
15ºC
Input 3.46 2.98 2.56 2.40 2.27
TC 11.25 8.93 7.23 6.79 6.25
20ºC
Input 3.78 3.20 2.82 2.59 2.43
TC 10.54 8.39 6.79 6.61 5.89
27ºC
Input 4.00 3.46 3.04 2.82 2.62
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 11.12 8.98 7.36 6.67 6.24
15ºC
Input 3.31 2.85 2.45 2.30 2.18
TC 10.78 8.55 6.93 6.50 5.99
20ºC
Input 3.62 3.07 2.70 2.48 2.33
TC 10.09 8.04 6.50 6.33 5.65
27ºC
Input 3.83 3.31 2.91 2.70 2.51
Note:
TC: Total capacity
Input: Input power
32 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 39.61 31.99 26.20 23.76 22.24
59ºF
Input (kW) 3.46 2.98 2.56 2.40 2.27
TC (KBtu) 38.39 30.47 24.68 23.15 21.33
68ºF
Input (kW) 3.78 3.20 2.82 2.59 2.43
TC (KBtu) 35.95 28.64 23.15 22.55 20.11
80.6ºF
Input (kW) 4.00 3.46 3.04 2.82 2.62
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 37.94 30.64 25.10 22.76 21.30
59ºF
Input (kW) 3.31 2.85 2.45 2.30 2.18
TC (KBtu) 36.77 29.18 23.64 22.18 20.43
68ºF
Input (kW) 3.62 3.07 2.70 2.48 2.33
TC (KBtu) 34.44 27.43 22.18 21.60 19.26
80.6ºF
Input (kW) 3.83 3.31 2.91 2.70 2.51
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 33
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 14.82 11.97 9.80 8.89 8.32
15ºC
Input 4.43 3.81 3.28 3.07 2.91
TC 14.36 11.40 9.23 8.66 7.98
20ºC
Input 4.84 4.10 3.61 3.32 3.12
TC 13.45 10.72 8.66 8.44 7.52
27ºC
Input 5.12 4.43 3.89 3.61 3.36
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 14.20 11.47 9.39 8.52 7.97
15ºC
Input 4.24 3.65 3.14 2.95 2.79
TC 13.76 10.92 8.85 8.30 7.64
20ºC
Input 4.64 3.93 3.46 3.18 2.99
TC 12.89 10.26 8.30 8.08 7.21
27ºC
Input 4.91 4.24 3.73 3.46 3.22
Note:
TC: Total capacity
Input: Input power
34 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 50.56 40.84 33.45 30.34 28.39
59ºF
Input (kW) 4.43 3.81 3.28 3.07 2.91
TC (KBtu) 49.01 38.89 31.50 29.56 27.23
68ºF
Input (kW) 4.84 4.10 3.61 3.32 3.12
TC (KBtu) 45.89 36.56 29.56 28.78 25.67
80.6ºF
Input (kW) 5.12 4.43 3.89 3.61 3.36
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 48.43 39.12 32.04 29.06 27.20
59ºF
Input (kW) 4.24 3.65 3.14 2.95 2.79
TC (KBtu) 46.94 37.26 30.18 28.31 26.08
68ºF
Input (kW) 4.64 3.93 3.46 3.18 2.99
TC (KBtu) 43.96 35.02 28.31 27.57 24.59
80.6ºF
Input (kW) 4.91 4.24 3.73 3.46 3.22
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 35
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 18.53 14.96 12.26 11.12 10.40
15ºC
Input 5.70 4.91 4.22 3.96 3.75
TC 17.96 14.25 11.54 10.83 9.98
20ºC
Input 6.23 5.28 4.65 4.28 4.01
TC 16.82 13.40 10.83 10.55 9.41
27ºC
Input 6.60 5.70 5.02 4.65 4.33
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 17.75 14.33 11.74 10.65 9.96
15ºC
Input 5.46 4.71 4.05 3.80 3.59
TC 17.20 13.65 11.06 10.37 9.56
20ºC
Input 5.97 5.06 4.45 4.10 3.85
TC 16.11 12.83 10.37 10.10 9.01
27ºC
Input 6.33 5.46 4.81 4.45 4.15
Note:
TC: Total capacity
Input: Input power
36 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 63.21 51.05 41.81 37.92 35.49
59ºF
Input (kW) 5.70 4.91 4.22 3.96 3.75
TC (KBtu) 61.26 48.62 39.38 36.95 34.03
68ºF
Input (kW) 6.23 5.28 4.65 4.28 4.01
TC (KBtu) 57.37 45.70 36.95 35.98 32.09
80.6ºF
Input (kW) 6.60 5.70 5.02 4.65 4.33
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 60.55 48.90 40.05 36.33 34.00
59ºF
Input (kW) 5.46 4.71 4.05 3.80 3.59
TC (KBtu) 58.68 46.57 37.72 35.40 32.60
68ºF
Input (kW) 5.97 5.06 4.45 4.10 3.85
TC (KBtu) 54.96 43.78 35.40 34.46 30.74
80.6ºF
Input (kW) 6.33 5.46 4.81 4.45 4.15
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 37
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 23.47 18.95 15.52 14.08 13.18
15ºC
Input 6.54 5.63 4.84 4.54 4.30
TC 22.74 18.05 14.62 13.72 12.64
20ºC
Input 7.15 6.06 5.33 4.91 4.60
TC 21.30 16.97 13.72 13.36 11.91
27ºC
Input 7.57 6.54 5.75 5.33 4.97
Low speed
Heating Outdoor conditions at 0Pa
24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC
Indoor Conditions (DB) (kW)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC 22.48 18.15 14.87 13.49 12.62
15ºC
Input 6.27 5.40 4.64 4.35 4.12
TC 21.79 17.29 14.00 13.14 12.10
20ºC
Input 6.85 5.80 5.11 4.70 4.41
TC 20.40 16.25 13.14 12.79 11.41
27ºC
Input 7.25 6.27 5.51 5.11 4.76
Note:
TC: Total capacity
Input: Input power
38 SSA-PRC008-E4
System performance data
Medium speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 80.05 64.66 52.96 48.03 44.95
59ºF
Input (kW) 6.54 5.63 4.85 4.54 4.30
TC (KBtu) 77.59 61.58 49.88 46.80 43.11
68ºF
Input (kW) 7.15 6.06 5.33 4.91 4.60
TC (KBtu) 72.66 57.88 46.80 45.57 40.64
80.6ºF
Input (kW) 7.57 6.54 5.75 5.33 4.97
Low speed
Heating Outdoor conditions at 0Pa
75.2/64.4ºF 44.6/42.8ºF 35.6/33.8ºF 23/21.2ºF 19.4/17.6ºF
Indoor Conditions (DB)
DB/WB DB/WB DB/WB DB/WB DB/WB
TC (KBtu) 76.68 61.94 50.73 46.01 43.06
59ºF
Input (kW) 6.27 5.40 4.64 4.35 4.12
TC (KBtu) 74.32 58.99 47.78 44.83 41.29
68ºF
Input (kW) 6.85 5.80 5.11 4.70 4.41
TC (KBtu) 69.60 55.45 44.83 43.65 38.93
80.6ºF
Input (kW) 7.26 6.27 5.51 5.11 4.76
Note:
TC: Total capacity
Input: Input power
SSA-PRC008-E4 39
Wiring diagram
.0
%/$&. &211(&7,21 %2$5'
&1 &1
&1 &1 &1
%52:1
5(' / 1 1
;7 $/$50 212)) ; < ( 7 ( 9
<* <*
(5525 72 &&0
287387 &200%86
40 SSA-PRC008-E4
Wiring diagram
&211(&7,21 %2$5'
&1 &1
&1 &1 &1
/ 1 1
;7 $/$50 212)) ; < ( 7 ( 9
<*
32:(5 (5525 72 &&0
287387 &200%86
<*
5(027( 72287'225 81,7
72 287'225 81,7 &21752/
127(3/($6( 86( 6+,(/' /,1(
SSA-PRC008-E4 41
Wiring diagram
',63/$<
%2$5'
72 :,5( &21752//(5
;3;6
5(027(
&21752/ .
<*
42 SSA-PRC008-E4
Wiring diagram
&203&$3
%/$&. %/8(
5 6
)$1
<* <*
)$1&$3 &203
%/8(
5('
& 5('
%/$&.
%/8(
%/$&.
:$<9$/9(
7(03(5$785(6(16252)
&21'(16$725
:,5,1*',$*5$0
287'22581,7
;3
%/$&.
%/8(
5('
;6
1
;7 ;7
7 ( <*
72,1'22581,7 72,1'22581,7
SSA-PRC008-E4 43
Wiring diagram
TO INDOOR UNIT
OUTDOOR UNIT
1 2(N) 3 4
TEMPERATURE SENSOR OF BLUE
CONDENSATOR
Notes:
XP1 RED BLACK This symbol
XS1 indicates
4-WAY the element
is optional,
BLUE the actual
OVERLOAD shape shall
XT2 RELAY prevail
T3 E BLACK BLACK
C BLUE
R(M) RED
TO INDOOR UNIT COMPRESSOR
S FAN
WHITE MOTOR
COMPRESSOR
Y/G CAPACITOR BLUE
FAN CAPACITOR
44 SSA-PRC008-E4
Wiring diagram
BLACK
VALVE CAP1
FAN2 BLUE
1 2
BLACK WIRING DIAGRAM
M BLUE BLUE R S WHITE
~ (OUTDOOR UNIT)
XT7
COMP
BLUE RED Y G
1 2
KM1 C
RED RED
CODE PART NAME
RED
CAP2 COMP COMPRESSOR
CAP1 COMPRESSOR CAPACITOR
A2 A1 RT3
FAN2 OUTDOOR FAN
CAP2 OUTDOOR FAN CAPACITOR
XP1
XS1 XT3 8-WAY TERMINAL
WHITE
BLACK
BLACK
RED
RED
VALVE REVERSING VALVE
XP1,XS1 CONNECTORS
Y G
RT3 PIPE TEMPERATURE SENSOR
L N 1 2 3 T3 E XT3 KM1 AC CONTACTOR
TO INDOOR UNIT
SSA-PRC008-E4 45
Wiring diagram
:+,7(
%/$&. < *
B B 5('
5('
.0
&$3 &2035(6625 581 &$3$&,725
&
&$3 5(' 5(' &$3
5(' )$1&$3$&,725
5(6
$ $ ;7 :$<7(50,1$/
57
&$3 ;7 :$<7(50,1$/
%/$&.
%/8(
;7;7 0,''/(7(50,1$/
:+,7(
%/$&.
.
%/8(
5('
BB BB
5('
. BB BB BB BB BB
9$/9( 5(9(56,1*9$/9(
3,3(7(03(5$785(6(1625
%/$&.(
5(/$<
< * .0 $&&217$&725
. +,*+35(6685(6:,7&+
72,1'22581,7
&$3 67$57,1*&$3$&,725
72,1'22581,7;7 ;7
5(/$< 67$57,1*5(/$<
: $ 5 1 , 1 * , )7 + (, 1 ' 2 2 58 1 , 7, 67 7 ' / 5(6 ',6&+$5*(5(6,67$1&(
6 ( 5 , ( 6 3 / ( $ 6 (3 8 77 + (/ , 1 ( 62 1; 7 7 2, 1 ' 2 2 58 1 , 7
; 7
6& 2 5 5 ( / $ 7 , 9 (3 $ 5 7
46 SSA-PRC008-E4
Wiring diagram
+352 .
&1
&1
;3
;3
&203
&1
;6
;6
)$1
&1 &1 &1 7
&$3
57
57
69
.0 .0
;7
+($7
69 ;7
;7 ;7
)$1
+352
7
&203 57
+($7(5
&$3 ;6
;7
;3
&1
.
1 57
;7 ;7
;7
7
SSA-PRC008-E4 47
Wiring diagram
:,5,1*',$*5$0
&1
&1
;3
;3
0$,1&21752/%2$5' 287'22581,7
&1
;6 ;3
&1
;6
;6
&2'( 3$571$0(
&1 &1 &1 &1 CT1
57
57
5('/2
%/8(1
69 :$<9$/9(
5('$
;7 .0
%/8(69
%/$&.+,
$ $
%/8(69
.0 $&&217$&725
5('$
:+,7(
<(//2:
%/$&./
%/8( %/$&./ +($7(5 &5$1.
69 %/$&. ;7 :$<7(50,1$/
%/8( 25$1*(
)$1 ;7 &211(&725
25$1*(
83 %/8(
;7
:+,7( +/352 +,*+/2:35(6685(6:,7&+
7:
5(' <(//2:
79 57 3,3(7(036(1625
%/8(1
&203
%/8(1 5('
;6 &211(&7256
78
&$3 +($7(5
:+,7( %/8(1 ;3 &211(&7256
%/8( . 7(033527(&76:,7&+
)$1 <*
'2:1
57 52207(036(1625
$ % & 1
5(' <(//2: ;7
;7 ;7 :$<7(50,1$/
<*
7 75$16)250(5
&$3
&7 &855(17'(7(&725
72,1'225;7 72,1'225;7
48 SSA-PRC008-E4
Wiring diagram
:,5,1*',$*5$0
&1
&1
;3
;3
0$,1&21752/%2$5' 287'22581,7
&1
;6 ;3
&1
;6
;6
&2'( 3$571$0(
&1 &1 &1 &1 CT1
57
57
69 :$<9$/9(
;7 .0
%/8(69
%/$&.+,
$ $
%/8(69
.0 $&&217$&725
5('$
:+,7(
%/8(1
25$1*(
<(//2:
%/$&./
%/8( %/$&./ +($7(5 &5$1.
69 %/$&. ;7 :$<7(50,1$/
%/8( 25$1*(
)$1 ;7 &211(&725
%/8(
;7 +/352 +,*+/2:35(6685(6:,7&+
7: :+,7(
5(' <(//2:
5('/2 79 57 3,3(7(036(1625
&203
5('
;6 &211(&7256
78
&$3 +($7(5
:+,7( %/8(1 ;3 &211(&7256
%/8( . 7(033527(&76:,7&+
)$1 <*
57 52207(036(1625
$ % & 1
5(' <(//2: ;7
;7 ;7 :$<7(50,1$/
<*
7 75$16)250(5
&$3
&7 &855(17'(7(&725
72,1'225;7 72,1'225;7
SSA-PRC008-E4 49
Dimensions
Indoor model
H G
B
E F D
A
A C
Air
Air rreturn opening
etur n op size
en ing size
J
I Air
A filter
Position
Po sition ssize
ize oof descensional
f des cen sional venventilation
tilation o penopening
ing
Air
A filter
Size of
Si z e o mounted
fm lug
ounted lug
Outline dOutline
imension air outAir
letoutlet
opening size airAirrereturn
turn opening size Size of
Size mounted lug
of mounted
Capacity dimension (mm) opening size (mm) opening size (mm) lug (mm)
(KBtu) A A B C D E F G H I J K L M
48~60 1200 300 865 800 80 968 40 204 1094 288 45 1240 500
50 SSA-PRC008-E4
Dimensions
Outdoor model
Dimensions (mm)
Model A B C D E F H
SSA-PRC008-E4 51
Service space
Indoor model
Ensure enough space required for installation and maintenance.
Outdoor model
52 SSA-PRC008-E4
Notes
SSA-PRC008-E4 53
Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and
sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems,
comprehensive building services, and parts.
For more information, visit www.Trane.com.
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.