The Compact Forwarding Engine Board (CFEB) on the M10i router provides route
lookup, filtering, and switching on incoming data packets, and then directs
outbound packets to the appropriate interface for transmission to the network. The
CFEB communicates with the Routing Engine using a dedicated 100-Mbps Fast Ethernet
link that transfers routing table data from the Routing Engine to the forwarding
table in the integrated ASIC. The link is also used to transfer from the CFEB to
the Routing Engine routing link-state updates and other packets destined for the
router that have been received through the router interfaces.
To manually switch CFEB mastership, issue the request chassis cfeb master switch
command.
******************************************************************************
Troubleshooting the M10i CFEB and CFEB-E
When a CFEB or CFEB-E is functioning correctly, the green LED labeled OK is lit
steadily.
If the CFEB or CFEB-E fails, the forwarding and routing functions of the router
halt immediately and do not resume until the CFEB or CFEB-E failure has been co
rrected.
1)Check the alarm LEDs on the HCM. If the yellow or red alarm LED on the HCM is
lit, issue the show chassis alarms
2)Verify that the CFEB or CFEB-E is properly seated in the midplane. Use a Phillips
screwdriver to ensure that the screws are securely tightened.
If you are unable to correct the problem, replace the CFEB or CFEB-E with a spare
If the LED lights correctly on the spare, the original CFEB or CFEB-E is faulty.
Return it to Juniper Networks
Red Both CFEBs/CFEB-Es have been removed or have failed. Replace failed or
missing CFEB/CFEB-E.
***********************************************************************************
**************************************
Troubleshooting the M10i HCM (High Availability Chassis Manager)
Solution
A green LED labeled PWR reports the status of the HCM. When an HCM is functioning
correctly, the green LED labeled OUTPUT OK is lit steadily.
Two LEDs Indicate HCM status. There is a green LED labeled PWR and an blue LED
labeled MSTR.
***********************************************************************************
****************************************
The HCM work with RE to provide control and monitoring function for router
components. The HCM also displays alarms status and takes PICs online and offline.
Two HCMs are installed into the midplane from the front of the chassis.
The master HCM performs all functions and provides PIC removal button for the first
FPC.
The Backup HCM provides PIC removal buttons for the second FPC.
The HCM0 is paired with RE0 and the HCM1 is paired with the RE1. By default HCM0 is
the master.
When HCM mastership changes because of failure, RE mastership will also change as
well.
The HCM collects statistics from all sensors in the system. When it detects a
failure or alarm condition, it sends a signal to the Routing Engine, which
generates control messages or sets an alarm. The HCM also relays control messages
from the Routing Engine to the router components.
3)Signaling of mastership
In a router with more than one Routing Engine, the HCM signals to all router
components which Routing Engine is the master and which is the standby.
4) Alarm display
If a PIC offline button is pressed, the HCM relays the request to the CFEB or
CFEB-E, which takes the PIC offline and informs the Routing Engine. Other PICs are
unaffected, and system operation continues
1)100-Mbps Fast Ethernet switch�Carries signals and monitoring data between router
components.
2)Two LEDs�Indicate HCM status. There is a green one labeled PWR and an blue one
labeled MSTR.
4)PIC offline buttons�Relays a request to the CFEB or CFEB-E, which prepares a PIC
for removal from the router, or brings the PIC online when it is replaced.Offline
buttons for one row of PICs are located on each HCM Pressing the button relays a
request to the CFEB or CFEB-E, which prepares the PIC for removal from the router,
or brings it online when it is replaced. The HCM in slot 0 controls PICs on FPC 0.
The HCM in slot 1 controls PICs on FPC 1. The buttons are labeled with the PIC slot
numbers. The PIC slots on the upper FPC are numbered from 0/0 (zero/zero) through
0/3, right to left. The PIC slots in the lower FPC are numbered from 1/0 (one/zero)
through 1/3, right to left.
***********************************************************************************
********************************************
M10i HCM Alarm LEDs
Two alarm LEDs are located on the right of the HCM.The circular red LED lights to
indicate a critical condition that can result in a system shutdown. The triangular
yellow LED lights to indicate a less severe condition that requires monitoring or
maintenance. Both LEDs can be lit simultaneously.
To deactivate red and yellow alarms, you must clear the condition that caused the
alarm.
Alarm LEDs
***********************************************************************************
****************************************
PIC offline/online
The offline button for each PIC is located on the HCM and is labeled with the PIC
slot number. The PICs in FPC 0 are located on the upper HCM, and the PICs installed
in FPC 1 are located on the lower HCM.
Press and hold the PIC offline button until the status LED on the PIC faceplate
indicates normal functioning, which usually takes about 5 seconds. The LED is
usually green
Warning: Do not look directly into a fiber-optic transceiver or into the ends of
fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a
transceiver emit laser light that can damage your eyes.
M10i MIDPLANE
All router components plug directly into the midplane. The midplane contains an
EEPROM that stores the serial number and revision level of the midplane.
2)switching and forwarding functions and transfers outgoing packets back across the
midplane to the PICs for transmission to the network.
Note: The M10i router supports the Routing Engine 400, Routing Engine 850, and
Routing Engine 1800.
One or two Routing Engines can be installed into the midplane from the front of the
chassis.If two Routing Engines are installed, the High-Availability Chassis Manager
(HCM) determines which is the master and which is backup (in standby mode and so
performs no functions). By default, the Routing Engine in the slot labeled RE0 is
the master.
Note: If two Routing Engines are installed, they must both be the same hardware
model.
The Routing Engine is hot-pluggable, If two Routing Engines are installed, removal
or failure of the backup Routing Engine does not affect router function. Removal or
failure of the master Routing Engine affects forwarding and routing based on the
high availability configuration: