Professional Documents
Culture Documents
MOY/SCMI/55
FOREWORD
In the 1940s and 1950s, NPL was involved in drafting a special series of
Specifications of Accuracy that covered a wide range of precision measuring
apparatus. This series has been built on first hand experience gained in the design and
construction of prototype measuring equipment at NPL and in the design and
calibration of measuring equipment of British and foreign manufacture. Each
specification in the series originally conformed to a general pattern and was allocated
a permanent serial number which, in addition to its title, serves as its identity.
MOY/SCMI/55 has been updated as part of a project financed by the DTI (MPU
8/61.3) concerned with Good Practice Guides and Equipment Specifications.
SCOPE
1
MOY/SCMI/55 (Issue 6):2001
CONTENTS
Page
1 GENERAL .............................................................................................................3
2 HARDNESS...........................................................................................................3
3 LENGTH................................................................................................................3
4 DIAMETER ...........................................................................................................3
5 CERTIFICATION..................................................................................................4
6 UNCERTAINTIES ................................................................................................4
7 REPORTING OF COMPLIANCE ........................................................................4
2
MOY/SCMI/55 (Issue 6):2001
1 GENERAL
1.2 A serial number shall be allocated to each set and shall be legibly
marked on the box.
1.3 A set shall comprise one roller of each of the following sizes:
3 1 5 3 7 1 9 5 11 3 13 7 15 1 1
, , , , , , , , , , , , , 1, 1 and 1 in
16 4 16 8 16 2 16 8 16 4 16 8 16 8 4
2 HARDNESS
2.1 The roller gauges shall be hardened and, when finished, shall have a
hardness of not less than 800 HV, when tested in accordance with BS
EN ISO 6507-1:1998.
3 LENGTH
3.1 The end faces of each roller gauge shall be flat to within 0.002 5 mm.
Any departure from flatness should be such that the faces are of convex
form.
3.2 The central length of each roller gauge shall agree with its nominal size
to within ± 0.002 5 mm.
4 DIAMETER
4.1 Each roller gauge shall be uniform in diameter to within 0.001 3 mm.
4.2 The mean diameter of each roller gauge shall agree with its nominal
size to within 0.002 5 mm.
4.3 Each roller gauge shall be free from lobes. When rotated in a 90° vee
block under a sensitive indicator, any variation in reading shall not
exceed 0.002 5 mm. Alternatively, this test may be performed with a
roundness measuring instrument.
3
MOY/SCMI/55 (Issue 6):2001
5 CERTIFICATION
6 UNCERTAINTIES
7 REPORTING OF COMPLIANCE
This set of angle gauges has been examined for compliance with the
accuracy requirements of clauses 2 and 3 of NPL Specification of
Accuracy MOY/SCMI/18 (Issue 5), a copy of which is attached to this
certificate.
4
MOY/SCMI/55 (Issue 6):2001
5
MOY/SCMI/55 (Issue 6):2001
For free measurement advice and information on other specifications in this series call