First setting before commissioning Shutdown ϑ0 = 120 °C
Setting in operation Alarm ϑ1 = ϑ + 10 K; max. 135 °C Shutdown ϑ2 = ϑ + 15 K; max. 140 °C
ϑ = temperature in the steady-state condition / °C
6.2 Cold-air temperature
First setting before commissioning Shutdown ϑ0 = 60 °C
Setting in operation Alarm ϑ1 = ϑ + 10 K; max. 70 °C Shutdown ϑ2 = ϑ + 15 K; max. 75 °C
ϑ = temperature in the steady-state condition / °C
6.3 Hot-air temperature
First setting before commissioning Shutdown ϑ0 = 90 °C
Setting in operation Alarm ϑ1 = ϑ + 10 K; max. 100 °C Shutdown ϑ2 = ϑ + 15 K; max. 105 °C
ϑ = temperature in the steady-state condition / °C
6.4 Bearing temperature
First setting before commissioning Shutdown ϑ0 = 110 °C
Setting in operation Alarm ϑ1 = ϑ + 5 K; max. 115 °C Shutdown ϑ2 = ϑ + 10 K; max. 120 °C
ϑ = temperature in the steady-state condition / °C
6.5 Bearing housing vibration
Comply with the specifications laid down in standard DIN ISO 10816-3. Setting values according to DIN ISO 10816-3.
Subassembly (foundation) Rigid Flexible
First setting before commissioning Alarm 4.5 mm s−1 7.1 mm s−1 Shutdown 7.1 mm s−1 11 mm s−1 Setting in operation Alarm v × 1.25 v × 1.25 Shutdown 7.1 mm s−1 11 mm s−1
v = measured basis value of the vibration velocity
Department responsible Technical reference Created by Approved by Project