6 Monitoring setpoints

6.1 Slot temperature

First setting before commissioning Shutdown ϑ0 = 120 °C


Setting in operation Alarm ϑ1 = ϑ + 10 K; max. 135 °C
Shutdown ϑ2 = ϑ + 15 K; max. 140 °C

ϑ = temperature in the steady-state condition / °C

6.2 Cold-air temperature

First setting before commissioning Shutdown ϑ0 = 60 °C


Setting in operation Alarm ϑ1 = ϑ + 10 K; max. 70 °C
Shutdown ϑ2 = ϑ + 15 K; max. 75 °C

ϑ = temperature in the steady-state condition / °C

6.3 Hot-air temperature

First setting before commissioning Shutdown ϑ0 = 90 °C


Setting in operation Alarm ϑ1 = ϑ + 10 K; max. 100 °C
Shutdown ϑ2 = ϑ + 15 K; max. 105 °C

ϑ = temperature in the steady-state condition / °C

6.4 Bearing temperature

First setting before commissioning Shutdown ϑ0 = 110 °C


Setting in operation Alarm ϑ1 = ϑ + 5 K; max. 115 °C
Shutdown ϑ2 = ϑ + 10 K; max. 120 °C

ϑ = temperature in the steady-state condition / °C

6.5 Bearing housing vibration

Comply with the specifications laid down in standard DIN ISO 10816-3.
Setting values according to DIN ISO 10816-3.

Subassembly (foundation) Rigid Flexible


First setting before commissioning Alarm 4.5 mm s−1 7.1 mm s−1
Shutdown 7.1 mm s−1 11 mm s−1
Setting in operation Alarm v × 1.25 v × 1.25
Shutdown 7.1 mm s−1 11 mm s−1

v = measured basis value of the vibration velocity

Department responsible Technical reference Created by Approved by Project


LDA OPS EU EN 002-DDT/1 Neibert Ebert
Document type Document status Customer tag
Technical data for configuration Released
Document number
SIMOTICS HV U202.5030997020.AC
1RQ6 562-4JT70-Z Rev. Language Page
Edition date (YYYY-MM-DD)
5030997/020/001 AC en 12/21
© Siemens 2022 2022-06-30