You are on page 1of 12

Biogas Plant

Chemical Fertilizer Plant


Plant

30 +
+
Years of Expertise

Largest
Manufacturer
of India Gas Skid

EV
Charging
Exporting to Station
More than
13 Countries LPG Storage Tanks
Visit our Factory
for Live
Demonstration Chemical
Waste
Recycling
Complete Range of Plant

Gas, Flame & Heat Power Plants

Detection Solutions
Manufacturing of : On site Services For :
• Toxic Gas Detectors/Transmitters • On site Calibration Services
• HC Gas Detectors/Transmitters • On site AMC/CMC
Commercial Kitchen
• Oxygen Gas Detectors/Transmitters • On site Installation and commissioning for
• VOC Gas Detectors/Transmitters • Customize Development Restaurants/Hotels
• Portable Gas Detectors • Repairing and Calibration of any Make and any Model
• Wireless Gas Detectors
• UV /IR Flame and Heat Detectors
• Ember Detectors
• Percent O2 Analyzer
• Trace Oxygen Analyzer
• Dew Point Analyzer
• Bio Gas Analyzer
• IoT System for remote monitoring on cloud &
Alerts via SMS/E-mail/Voice call

+91-22-61673056 +91-93207 37646 sales8@ambetronics.com


+91-22-61673021/22 +91-91674 18106 sales11@ambetronics.com www.ambetronics.com
RANGE OF GAS DETECTORS & TRANSMITTERS
Loop Powered Detector Oxygen/NDIR/Toxic -(2 Wire) Smart Gas Detector - Combustible - (3 Wire)
GT-1033-WP GT-1033-FLP GT - 4000 - WP GT-4000-FLP-HCF
• 2 Line L.C.D. Display
with backlight 0100
LEL
• Pluggable Sensor
module • 2 Line L.C.D. Display • 2 x4 digit
with backlight L.E.D. Display
• Toxic/O2/NDIR-CH4 • Pluggable Sensor module
Gas Detection • 2 x4 digit L.E.D. Display • CH4
• Toxic/O2 /NDIR-CH4 • CH4
• 2 wire 4-20mA O/P & Gas Detection • 3 Wire, 4-20mA Output
HART output available • HART output available • 3 Wire, 4-20mA Output • Exd IIC T6 Gb
• IP65 Enclosure •Ex d IIC T6 Gb • IP66 • IP65 Enclosure •IP66/IP68 Enclosure

Smart Gas Detector Oxygen/Toxic/Combustible - (3 Wire / 4 Wire)


GT - 2500 - WP GT-2500-FLP-HCF GT-2500-FLP-SS-HCF GT-2500-FLP-HCF-JB-150
SMART GAS DETECTOR
GT-2500-FLP

• 2 Line L.E.D. Display


SET
NEXT SHIFT INCR

• 2 Line L.E.D. Display


• 2 Line L.E.D. Display • 2 Line L.E.D. Display • 3 Wire 4-20mA
• 3 Wire, 4-20mA O/P HOOTER
• 3 Wire 4-20mA • 3 Wire 4-20mA
CUM • Isolated RS-485 O/P • Isolated RS-485 O/P
• 3 Nos.Relay FLASHER • Isolated RS-485 O/P • With Hooter cum Flasher
(AL1, AL2, Failsafe) FOR ALARM
• With Hooter cum Flasher • With Hooter cum Flasher
• Isolated RS-485 O/P •Ex d IIC T6 Gb •Ex d IIC T6 Gb •Ex d IIC T6 Gb
• IP65 Enclosure • IP66/IP68 Enclosure • IP66/IP68 Enclosure • IP66/IP68 Enclosure

Smart Gas Transmitter Oxygen/Toxic/Combustible - (3 Wire / 4 Wire)


GT-2511-WP GT-2511-FLP-HCF GT-2511-FLP-SS-HCF GT-2511-FLP-HCF-JB-150
SMART GAS DETECTOR
GT-2511-FLP

• L.C.D. Display •L.C.D. Display


• L.C.D. Display SET

•L.C.D. Display
NEXT SHIFT INCR

• 3 Wire, 4-20mA O/P HOOTER • 3 Wire with HART •3 Wire with HART
• 3 Nos. Relay CUM •3 Wire with HART HOOTER
• With Hooter cum Flasher
FLASHER • With Hooter cum Flasher
CUM
FLASHER
• 3 Nos. Relay
(AL1, AL2, Failsafe) FOR ALARM
• Isolated RS-485 O/P FOR ALARM • Isolated RS-485 O/P • Isolated RS-485 O/P
• Isolated RS-485 O/P •Ex d IIC T6 Gb •Ex d IIC T6 Gb •Ex d IIC T6 Gb
• IP65 Enclosure • IP66/IP68 Enclosure •IP66/IP68 Enclosure • IP66/IP68 Enclosure

Smart Gas Transmitter Oxygen/Toxic/Combustible LNG/LPG/CNG/PNG Gas Leak Detector


GT-2460-FLP GT-2461-FLP-HCF GT-4220-WP GT-4220-FLP
• L.E.D. Display • L.C.D. Display
• 4 Wire, • 4 Wire,
2x 4-20mA O/P 2x 4-20mA O/P 0

•1 x 4 digit L.E.D. Display •1 x 4 digit L.E.D. Display


• 3 Nos. Relay • 3 Nos. Relay •2 Nos. Relay •2 Nos. Relay
Sound (AL1, AL2, Failsafe) Sound (AL1, AL2, Failsafe)
level : level : •Isolated RS-485 I/P or •Isolated RS-485 I/P or
110 dB • Isolated RS-485 O/P 110 dB • Isolated RS-485 O/P •Isolated 4-20mA I/P •Isolated 4-20mA I/P
•IP65 Enclosure •Ex d IIC T6 Gb • IP66/IP68 Enclosure

Stand Alone Smart Gas Detector / Monitor


GA-3500-WP-D GA-3500-FLP-D GA-3511-WP-D GA-3511-FLP-D

• L.E.D. Display • L.E.D. Display • L.C.D. Display


• 3 Nos. Relay •L.C.D. Display
• 3 Nos. Relay 20.90
uoL • 2 Nos. Relay
• 4 -20mA O/P •3 Nos. Relay
• 4 -20mA O/P • 4 -20mA O/P
• Isolated •4 -20mA O/P • Isolated
• Isolated RS-485 O/P •Isolated RS-485 O/P
RS-485 O/P • Ex d IIC T6 Gb RS-485 O/P • 230VAC
• 230VAC • 230VAC •230VAC •Ex d IIC T6 Gb
• IP65 Enclosure • IP66 Enclosure •IP 65 Enclosure •IP66 Enclosure

Smart Gas Transmitter Battery Powered Gas Detector Oxygen/Toxic Battery Powered Gas Detector
(with HART ) Oxygen/Toxic/Combustible
GT-5022-FLP BGD-6033-WP BGD-6033-FLP WGD-100-FLP

• Pluggable Sensor Module •2 Line L.C.D. Display • 2 Line L.C.D. Display


• EC/ NDIR/PID • 1 year Battery Life
•Isolated RS-485 O/P • 1 year Battery Life
• Toxic/O2 Gas Detection •Battery Operated
•3 Nos. Relay • Toxic/O2 Gas Detection •upto 1 year Battery life
•With Hooter cum Flasher • Inbuilt Buzzer • Ex d IIC T6 Gb
•SMS /E-mail Facility to
• Ex d IIC T6 Gb • IP66/IP68 Enclosure • IP65 Enclosure • IP66/IP68 Enclosure control room •IP-66 Enclosure
* FLP - Flameproof Enclosure * WP - Weatherproof Enclosure * HCF - Hooter cum Flasher * GT - Gas Detector *SS - Stainless Steel (SS316) * BGD- Battery Powered Gas Detector 2
RANGE OF ACCESSORIES FOR GAS DETECTORS
Gas Leak Detector for Domestic / Commercial Kitchens for
detecting leak of LPG / CNG / PNG /Natural Gas /Flammable Gas Clean Room Monitor for Oxygen & Toxic Gases
GLA-222-T GLA-222 GLA-222-FLP CRM-111-2 CRM-131-2
GLA-222-B
• 1” Red L.E.D. display
CLEAN ROOM MONITOR

• Integrated Buzzer • Integrated Buzzer


• Smallest gas leak with
integrated Buzzer & 2 0.90 • 2 Nos. SPDT Relay 0000 PPM
• 2 Nos. DPDT Relay
L.E.D. indication • Isolated RS-485 with • Isolated RS-485
• Easy Installation Modbus RTU Protocol Modbus RTU
• Smallest gas leak with integrated Buzzer & • Helps to detect Gas & Excess Temp. indication • Panel Mounting AMBETRONICS CRM-131-2 Protocol
L.E.D. indication • simple Plug-in design for home use • Panel Mounting
•Helps to detect Gas & Excess Temp. indication • 230VAC powered

Flameproof Junction Box Flameproof Junction Box Smart Alert System (RS-485) Addressable Call Point
JB-150-FLP JB-500-FLP SAR-321-FLP ACP-321-FLP
HCF/JB/FLP/2C

FLAMEPROOF
HOOTER CUM FLASHER

• Isolated RS-485 • Self test facility


• One Transmitter •Monitoring device
I/P & O/P Communication port
with MODBUS RTU relay contacts can
connection connected as Digital Output
• M20 •Repeater Detector Monitor
• 24V, GND, O/P, •Remote acknowledged Key •Self test facility • Remote acknowledged Key
• IP66 D+, D- Signals •Hooter & Flasher ON/OFF pattern is •Hooter & Flasher ON/OFF pattern is
• No. of Glands - 10 • Weatherproof enclosure available programmable •IP66 / IP68 Enclosure programmable •IP66 / IP68 Enclosure
Flameproof Flameproof Weatherproof Weatherproof
Hooter-cum-Flasher Hooter-cum-Flasher- BIG Hooter cum Flasher Hooter cum Flasher
HCF-FLP-2C HCF-FLP-B-IIC HCF-WP-S-RH HCF-WP-B-RH

• Red/Green/ • Red/Green/Amber Flasher • Red/Green/Amber Flasher • Red/Green/Amber Flasher


Amber Flasher • Sound level : 105 dB/110 dB • Sound level : 95 / 100 dB • Sound level : 105 dB/110 dB
• Sound level : 95/100 dB
•Stainless Steel 316/304
•Stainless Steel 316 / 304 • M-12/M-20 Connection
• M-20 Connection • M-20 Connection
• M-20 Connection • 24 VDC Supply
• 24VDC I/P • 24 VDC Supply
• 24 VDC Supply
•IP66 •IP66
Weatherproof Weatherproof Junction Box Gas Detector Calibration Gases M.S Gas Collection Cone
Hooter cum Flasher Oxygen/Toxic / Combustible
HCF-WP JB-400-WP AEPL-CG-3/CG-0.5 AEPL-SHA-406
• ABS Plastic Enclosure • 4 No. Transmitter
• Red/Green/Amber I/P & O/P
connection 400 mm Dia x 100 mm
Flasher
•M-12/M-20 Connection • 24V, GND, O/P, x 2mm thickness
D+, D- Signals • Canister
connections(6core) •SHA-407 :
• Sound level : 110 dB • Fix Flow Regulator
• IP 65 200 mm Dia x 100 mm
• 12/24 VDC Supply • ‘Normally open’ Relay contact connectivity
• Calibration Cap x 2mm thickness
• Inbuilt DPDT Relay for Hooter connection. • PVC Pipe Hose

Chemical Resistance Canopy MS Canopy SS-316 Canopy Floor Mounting Stand


AEPL-CR-CANOPY AEPL-CAN-016 AEPL-CAN-JB-250-A AEPL-CAN-023 AEPL-CAN-JB-IIC-A Front side Back side CANOPY STAND
Transparent Canopy Base plate Base plate Base plate Base plate Front side
with front cover Back side
without front cover with front cover without front cover
•For Rain & Dust
protection

•For Rain & Dust protection •For Rain & Dust protection

Double Compression Stopper Plug Relay Module Smart IoT System


Cable Gland
M-20-CG/FLP/2C SP-FLP-2C REL-1200 SIS4G485

• 32 Channels
•Brass with Nickel plated •Brass with Nickel plated • Selectable Slave • GSM/GPRS
•Stainless Steel 316 (optional) •Stainless Steel 316 (optional) address. Connectivity
•Ex d IIC T6 Gb IP66 •Ex d IIC T6 Gb IP66 • Micro controller based programming • 2 Nos. SIM card slots
•M20, M25, ½” NPT, ¾” NPT •M20, M25, ½” NPT, ¾” NPT • Password protector programming • RS-485 MODBUS RTU I/P & O/P
• Isolated RS-485 Communication Port •10 Mobile Nos. Voice call & SMS
• 2 Nos Relays output • 5 E-mail address
* JB- Junction Box * HCF - Hooter cum Flasher * Kindly ask for detail Catalogue and specification of each product 3
RANGE OF GAS DETECTORS & TRANSMITTERS
Loop Powered Gas Detector/ Transmitter Smart Gas Detector / Transmitter for
for Oxygen/Toxic/Combustible/IR
Model No.: GT-1033-WP GT-1033-FLP GT-2500-WP GT-2500-FLP-HCF GT-2500-FLP-HCF-JB-150 GT-2511-WP

SMART GAS DETECTOR


GT-2500-FLP

SET
NEXT SHIFT INCR

Product
Specifications
GENERAL 2 Wire 2 Wire 3 Wire / 4 Wire 3 Wire / 4 Wire 3 Wire / 4 Wire 3 Wire / 4 Wire
• 2 Wire / 3 Wire / 4 Wire
• Pluggable Sensor module
Gases Detected :
O2 / Toxic / Combustible / VOC O2 / Toxic /NDIR / CH4 O2 / Toxic/Combustible/VOC

Detection Method : • Electrochemical


•Electrochemical / Catalytic Bead • IR-(only for CH4 ) •Electrochemical •Catalytic Bead •Pellistor •PID • Hot Swappable Sensor
•Pellistor•VOC•IR•PID•Solid State • Hot Swappable Sensor
Display : 2 Line x 4 Digit,
2 Line x 4 Digit, L.C.D. Display
•L.C.D. Display with Backlit L.C.D. Display
•L.E.D. Display 2 Line x 4 Digit L.E.D. Display
Alarm : •with Buzzer & Flasher Optional Optional Optional Optional
•Inbuilt Buzzer
Output : •4-20mA + HART + HART + HART + HART
•No. of Relay Output 3 3 3 3
•Isolated RS-485 Optional Optional Optional Optional
PERFORMANCE
Accuracy : ±2% of Full Scale.
±2% of Full Scale. ±2% of Full Scale. ±2% of Full Scale.
Response Time :
•Toxic & O2 : 15 Sec. #
•Combustible gases : 15 Sec.
SUPPLY VOLTAGE
• Battery Supply
• 18 to 36 VDC, Typically 24VDC Loop Powered Loop Powered 24V DC
Power Consumption : Less than 3.6 Watts
ENVIRONMENTAL
Operating Temp. : -20°C to +600C -20°C to +600C -20°C to +600C -20°C to +600C -20°C to +600C -20°C to +600C
Storage Temperature : -30°C to +700C -30°C to +700C -30°C to +700C -30°C to +700C -30°C to +700C -30°C to +700C
Humidity : Less than 95% Non-Condensing.
HOUSING
Cabinet Material :
• Polycarbonate , Grey Colour
•Cast Aluminium alloy, LM-6
Protection Class :•IP65•IP66•IP68 IP65 IP66/IP68 IP65 IP66/IP68 IP66/IP68 IP65
Enclosure Approval :
•CIMFR Tested / PESO Approved
•Ex d IIC T6 Gb
•EMI/EMC - BS EN 50270
•Intrinsically Safe
Dimension : with Buzzer & Flasher 180(H) x180(W)x70(D) 225 (H) x 266 (W) x 122(D) 277(H) x 310(W) x 154(D) 180(H) x 180(W) x 70(D)
in mm
Dimension : without Buzzer & Flasher 180(H) x132(W) x70(D) 197 (H) x197(W) x 97(D) 180(H)x132(W)x70(D) 225 (H) x 225(W) x122(D) 277(H) x 271(W) x 154(D) 180(H) x 132(W) x 70(D)
in mm
Sensor Holder : • SS • ABS Plastic ABS Plastic SS-316 ABS Plastic SS-316 SS-316 ABS Plastic
Cable Entry : •Thermoplastic gland
•Double compression cable gland
(Ex-Proof) M20 x 1.5P
Mounting : •Wall•Stand•Pipe •Wall •Stand •Pipe •Wall•Stand•Pipe •Wall•Stand•Pipe •Wall•Stand•Pipe •Wall •Stand •Pipe
Weight : 400 Grams 500 Grams 2.5 Kg- With HCF 5.5 Kg - With HCF 500 Grams
1.25 Kg - Without HCF
Without HCF With HCF With HCF
ACCESSORIES (OPTIONAL) •CE certified 24VDC Power Supply •Gas Sampling & Conditioning System •Gas Calibration Kit

- For better accuracy please contact to factory # - For better Response Time please contact to factory * FLP - Flameproof Enclosure * WP - Weatherproof Enclosure 4
RANGE OF GAS DETECTORS & TRANSMITTERS
Oxygen /Toxic/Combustible / IR / VOC LPG/CNG/PNG Gas Leak Detector Battery Powered Gas Detector
GT-2511-FLP-HCF GT-2511-FLP-HCF-JB-150 GT-4000-FLP GT-4220-WP GT-4220-FLP WGD-100-FLP
SMART GAS DETECTOR
GT-2511-FLP

0000
LEL 0
SET
NEXT SHIFT INCR

3 Wire / 4 Wire 3 Wire / 4 Wire 3 Wire 3 /4 Wire 3 / 4 Wire Battery Powered Upto 1 year Battery Life

O2 / Toxic / IR / Combustible / VOC LPG / PNG Combustible O2 / Toxic / IR

•Electrochemical •Catalytic Bead •Pellistor •Electrochemical


•Catalytic Bead •Pellistor • Semicondecter •IR
•PID • Hot Swappable Sensor
•Hot Swappable Sensor
2 Line x 4 Digit, L.C.D. Display 3.5 inch Graphical Display
1 x4 Digit L.E.D. Display
Optional Optional Optional Optional Optional

+ HART + HART 4-20mA Output 4-20mA Output 4-20mA Output


3 3 2 2 2 2
Optional Optional Optional Optional

±2% of Full Scale. ±2% of Full Scale.

24V DC 24V DC
Less than 3.6 Watts Less than 1.5 Watts
-20°C to +600C -20°C to +600C -20°C to +600C -20°C to +600C -20°C to +600C -20°C to +600C

-30°C to +700C -30°C to +700C -30°C to +700C -30°C to +700C -30°C to +700C -30°C to +700C
Less than 95% Non-Condensing.

IP66/IP68 IP66/IP68 IP66/IP68 IP65 IP66/IP68 IP66/IP68

225 (H) x 266 (W) x 122(D) 277(H) x 310(W) x 154(D) 160 (H) x 234 (W) x 97(D) 143(H)x 180(W) x70(D) 160 (H) x 234 (W) x 97(D)

225 (H) x 225(W) x 122(D) 277(H) x 271(W) x 154(D) 160 (H) x 197(W) x 97(D) 143(H)x132(W) x70(D) 160 (H) x 197(W) x 97(D) 225 (H) x 347 (W) x 120 (D)
SS-316 SS-316 SS-316 ABS Plastic SS-316 SS-316

•Wall•Stand•Pipe •Wall•Stand•Pipe •Wall•Stand•Pipe •Wall•Stand•Pipe •Wall•Stand•Pipe •Wall•Stand•Pipe

2.5 Kg-With HCF 5.5 Kg-With HCF 1.75 Kg.-With HCF 500 Grams 1.75 Kg.-With HCF 3.5 Kg.
With HCF

- For better accuracy please contact to factory # - For better Response Time please contact to factory * HCF - Hooter cum Flasher * GT - Gas Detector 5
RANGE OF GAS MONITORS & PANELS
Dual Channel Gas Monitors Gas Monitoring System
GM-2200-MS GM-2200-FLP GM-416-WP GM-416-FLP

0000 0000
• Dual Channel Ch.01 Ch.01 •Ring topology
• I/P 4-20mA •Ring topology possibility
• Dual Channel
• 2 Nos. Relay possibility • 3 Nos. Relay
• I/P 4-20mA
• RS-485 • 3 Nos. Relay • Multidrop RS-485
• 2 Nos. Relay • All channels
• RS-485 O/P • Ex d IIC T6 Gb • Multidrop RS-485 MODBUS ID
• IP-54 • IP-66 •All channels MODBUS ID monitoring system monitoring system

Gas Monitoring System Conventional Multi Channel Gas Monitors (8 Channel)


GM-416-MS TC-800-MS TC-800-WP TC-800-FLP
• 8 channel
0000 • I/P 4-20mA • I/P 4-20mA
Ch.01 • 8 channel
0 0 • 2 Common • 2 Common • I/P 4-20mA
•Ring topology Relay O/P Relay O/P • 2 Common Relay O/P
possibility •Add-on Relay •Add-on Relay •Add-on Relay
• 3 Nos. Relay • Isolated • Isolated •Isolated RS-485 O/P
• Multidrop RS-485 RS-485 O/P RS-485 O/P •Ex d IIC T6 Gb
•All channels MODBUS ID monitoring system • IP-54 • IP65 • IP66

Conventional Multichannel Gas Monitor (16 Channel)


UIP-1600-PANEL UIP-1600-MS UIP-1600-WP UIP-1600-FLP
•16 Channel • 16 Channel • 16 Channel
• I/P 4-20mA • I/P 4-20mA • I/P 4-20mA
• 4 Common • 4 Common • 4 Common • 16 Channel
Relay O/P Relay O/P Relay O/P • I/P 4-20mA
• Add-on Relay • Add-on Relay
• Add-on Relays • 4 Common Relay O/P
• Isolated • Isolated
RS-485 O/P RS-485 O/P • Isolated • Add-on Relays
• USB data Logging • USB data Logging RS-485 O/P • USB data Logging
• Ethernet WiFi • Ethernet WiFi • USB data Logging • Isolated RS-485 O/P
• Lora & Lorawan • Lora & Lorawan • IP65 •Ex d IIC T6 Gb• IP66

Conventional Multi Channel Gas Monitoring Panel Multichannel Gas Monitor


Panel - 80 Channel
•HMI Size Supported: IM-48 -16/24/32 RK-220- 8 Channel RK - 220 - 16 Channel RK - 220 - 80 Channel
7”, 10.2” & 15”
• 4-20mA Input optional • 3 Digit LED Display • 3 Digit LED Display
• RS-485 Input • 20 Segment Bar graph • 20 Segment Bar graph
• RS-485 Output optional • I/P : 4-20mA • I/P : 4-20mA
• TCP / IP (Optional) • O/P : 4-20mA (Isolated) • O/P : 4-20mA (Isolated) Per Channel
• Alarm indication • 4 Relay O/P (Isolated) • 4 Relay O/P (Isolated) • 3 Digit LED Display
• 24 VDC or Potential • RS-485 O/P (Isolated) • 20 Segment
• RS-485 O/P (Isolated)
free 8/16/24 channel •Panel Size in mm : •Panel Size in mm : Bar graph
Relay outputs for 500 x 500 x 400 600 x 600 x 400 • I/P : 4-20mA
Valves & Alarms (W) x (H) x (D) (W) x (H) x (D)
• O/P : 4-20mA
(Isolated)
Addressable Multichannel Gas Monitors with inbuilt GSM Modem ( Upto 48 Channel) • 4 Relay O/P
SIG 4GTY-MS SIG 4GTY-WP SIG 4GTY-FLP (Isolated)
• 4 DPDT Relay • 4 DPDT Relay • RS-485 O/P
• Isolated RS-485 •4 DPDT Relay (Isolated)
• Isolated RS-485
O/P for SCADA/PLC O/P for SCADA/PLC •Isolated RS-485 • SCADA Software
• MQTT Protocol O/P for SCADA/PLC
• MQT T Protocol • Redundant
• 2 Settable Alarm • MQT T Protocol Power Supply
for each channel • 2 Settable Alarm
for each channel • 2 Settable Alarm • Ethernet
• Ethernet for each channel • SMS Faciality
• Wi-Fi • Ethernet • Wi-Fi Complete Panel Size in mm :
• Lamp Test facility • Lamp Test facility 2300 (H) x 600(W) x 600 (D)
•Ex d IIC T6 Gb •IP66• SMS & Email Alerts

Addressable Multi Channel Gas Monitors (Upto 80 Channel)


MCC-1322-MS MCC-1322-WP MCC-1322-FLP MCC-1322-PANEL
• Modbus RS-485 • Modbus RS-485 • Modbus RS-485
• Modbus RS-485 Input Input
Input Input
• 2 Common Relay • 2 Common Relay • 2 Common Relay
• 2 Common Relay
• 1 fault Relay
• 1 fault Relay • 1 fault Relay • 1 fault Relay
• Add-on Relay
• Add-on Relay • Isolated • Add-on Relay • Add-on Relay
• Isolated RS-485 O/P • Isolated RS-485 O/P • Isolated
RS-485 O/P RS-485 O/P
• IP65 •Ex d IIC T6 Gb • IP66
* Product images are only for representation, Actual image and size may differ * Kindly ask for detail Catalogue and specification of each product * MS - Mild Steel 6
RANGE OF PORTABLE GAS & FLAME DE TECTORS & ANALYZERS
Portable Single Gas Detector Dual Channel Gas Detector
PG-100-G PG-100-D PG-100-S PG-200-D
• Intrinsically safe • Intrinsically safe • Intrinsically safe
• External Sensor with • Pluggable Sensor Module • Pluggable Sensor Module • EC /NDIR sensor
Flexible Gooseneck Probe • EC/Catalytic/NDIR/PID • EC/Catalytic/NDIR/PID
• STEL/TWA Alarms
• EC/Catalytic/NDIR/PID • STEL / TWA Alarms • Integrated pump
• STEL / TWA Alarms • 50,000 log records • STEL/TWA Alarms • 50,000 log records
• 50,000 log records • > 10 hours backup • 50,000 log records • > 10 hours backup
• > 10 hours backup • USB interface • > 10 hours backup
• USB interface
• USB interface Oxygen-0 T0 25.00% V/V • USB interface
• Ex ia IIC T6 Ga PORTABLE GAS DETECTOR

• Ex ia IIC T6 Ga AMBETRONICS PG-100


•Ex ia IIC T6 Ga

Portable Multi Gas Detector (4 CH.) Portable Multi Gas Detector (8 CH.)
PG-400-D PG-400-S PG-800-D PG-800-S
•Diffusion type •Suction type •Diffusion type •Suction type
•Graphical L.C.D. display. •Graphical L.C.D. isplay. •Graphical L.C.D. display. •Graphical L.C.D. isplay.
•EC/Catalytic/NDIR/PID •EC/Catalytic/NDIR/PID •EC/Catalytic/NDIR/PID •EC/Catalytic/NDIR/PID
• STEL/TWA Alarms • STEL/TWA Alarms • STEL/TWA Alarms • STEL/TWA Alarms
•1,00,000 records •1,00,000 records •1,00,000 records •1,00,000 records
•> 8 hours backup •> 8 hours backup •> 8 hours backup •> 8 hours backup
• USB interface • USB interface • USB interface • USB interface

Portable Biogas Analyzer Biogas Analyser - Panel Mount Stand Alone Gas Analyzer Stand Alone Gas Analyzer
BIO-400-S-PEL BIOGAS ANALYSER BIO-400-S-PANEL GA-3500-WP GA-3511-WP
• Panel type housing
BIOGAS ANALYSER
•L.E.D. Display •L.C.D. Display
• Special Suitcase casing • 128 x 64, Graphic
CH4 - 0 -100% LEL
CO2 - 0 -100% V/V
O2 - 0 -25% V/V •Highly resistant •Highly resistant
L.C.D. display &
H2S - 0 -2000 PPM

to poisoning &
BIO-400-S-PANEL

• 128 x 64, Graphic to poisoning &


L.C.D. display & backlight backlight etching. etching.
• Event logging • Event logging •Capable of •Capable of
• CH4,CO2, O2, H2S Detection • USB interface detecting down to detecting down to
• CH4,CO2, O2, H2S Detection • 4-20mA signal O/P PPM & %V/V. • 4-20mA signal O/P PPM & %V/V.
• Optional 1,00,000 logging records • Optional 1,00,000 logging records •Optimized for detection of smallest leak of •Optimized for detection of smallest leak of
• USB interface• Li-po rechargeable Battery • Li-po rechargeable Battery Oxygen & Toxic Gases. Oxygen & Toxic Gases.

Dew Point Monitor Dew Point Sensor Smart Gas Analyzer - Oxygen
DEW POINT MONITOR DP-600-WP FA : 510/515 GA-3500-PM-O2 GA-3511-PM-O2
DEW Point
Sensor • 0-100% V/V • 0-100% V/V
Dew Point
DEW Point • 2 Line L.E.D. Display • 8 x 2 L.C.D. Display
Sensor Transmitter
DP-600-WP
• Built in O2 Sensor • Built in O2 Sensor
•2 Wire or 3 Wire
•4-20mA or • 4 -20mA O/P • 4 -20mA O/P
RS-485 Output • 3 Relay O/P • 3 Relay O/P
• Single Channel •Isolated RS-485 O/P •Range : -60 to 60 Ctd • RS-485 O/P
-110 to 20 Ctd • RS-485 O/P
•I/P- 4-20mA • 2 Nos. Relay
•IP65 •IP65 • Panel Mounted • Panel Mounted

UV & Triple IR Flame Detector UV & Triple IR Flame


(Radiant Energy) Detector UV & Triple IR Flame Detector Ember (Radiant Energy) Detector
FLD-3311-WP FLD-3311-FLP FLD-3311-FLP-SS EMB-7700-FLP
•3 Relay O/P •Insensitive to
• UV & 3IR Detection •4-20mA O/P sunlight
• Fast response < 3 sec. •3 Relay O/P

• 3 Relay O/P
•4-20mA O/P •Exd IIC T6 IP66 • Date-time stamped
• 4-20mA O/P
•Exd IIC T6 IP66 •SS Enclosure event logging
• Bluetooth, RS-485 or • UV & 3IR Detection
•UV & 3IR Detection •Built in self test (BIT)
HART configurable • Fast response <3 sec.
•Fast response <3 sec. •User programmable via Bluetooth, HART or RS-485.
• Built in Hooter cum Flasher • IP65 •Bluetooth, RS-485 or HART configurable •Bluetooth, RS-485 or HART configurable •Test Lamp compatibility for safe Test

Fixed Temperature Heat Detector UV/IR Flame Detector Test Lamp Flame Detector Mounting Stand Flame Detector Sun Shield
HTD-8811-FLP FTU-3311 Mounting stand JB IIC Sunshield Sun Shield
JB 90 Sunshield

•Provides a fast &


reliable response by
sensing heat build-up • Battery Operated • Diameter (Outer) : • JB IIC : 149 mm
•Factory Preset to • Cover Range : 3 to 5 meter • Total Length 275 mm • JB 90 : 112 mm
• Continuous Operation time : 1 hr. 30 min. Max. • Total Length : • JB IIC : 126 mm
required Temp. • Material : Aluminium (LM-6) • JB 90 : 103 mm
• Wide ranges of Temp. 40°C to 210°C • Operating Temp. : 0°C to 50°C • 180° Rotation • Material : Neoprence rubber
* FLP - Flameproof Enclosure * WP - Weatherproof Enclosure * S - Suction Type * D - Diffusion Type * HCF - Hooter cum Flasher 7
RANGE OF GAS MONITORS & PANELS
Multi Channel Gas Monitor Dual Channel Gas Monitor Multi Channel

Model No.: GM-416-FLP GM-416-WP GM-416-MS GM-2200-FLP GM-2200-MS TC-800-WP

0000
Ch.01 0000 0000
Ch.01 Ch.01

Product
Specifications
GENERAL
Channel Capacity :1CH./2CH./ 8CH./16CH./24 CH. 8CH./16CH./24 CH. 8CH./16CH./24 CH. 2 CH. 2 CH. 8 CH.
4CH./6CH./8CH./12CH.upto-80CH
Input Digital Input Digital Input Digital Input 4-20mA from Gas Transmitter Toxic /Combustible /VOC /IR/UV Flame Detector Etc.
Output :
•Isolated 4-20mA
•No. of Relay Output 3 3 3 3 3 2

•Isolated RS-485 (Optional)

Keys for Settings : 3 Keys 3 Keys 3 Keys 4 4 5


• 3 Keys •4 Keys • 5 Keys
2 Line x 4 Digit 2 Line x 4 Digit 1 Line x 5 Digit
Display : Single / Dual Display Dual Display Dual Display Dual Display
L.E.D. Display L.E.D. Display L.E.D. Display

0 to 9999 0 to 9999 0 to 9999 0 to 9999 0 to 9999 0 to 9999


Range :
PPM, % LEL, % V/V PPM, % LEL, % V/V PPM, % LEL, % V/V PPM, % LEL, % V/V PPM, % LEL, % V/V PPM, % LEL, % V/V

Programmable Programmable Programmable Programmable Programmable Programmable


Resolution : 0, 0.1,0.01 0, 0.1,0.01 0, 0.1,0.01 0.001, 0.01, 0.1,1 0.001, 0.01, 0.1,1 0.001, 0.01, 0.1,1

Very LO/LO & HI/ Very LO/LO & HI/ LO/HI, HI/LO, LO/
Control Action : High /Very Hi High /Very Hi High /Very Hi
Programmable by user Programmable by user Programmable by user very Hi logic very Hi logic Very LO, Hi-very Hi logic
Programmable by user Programmable by user Programmable by user

3mm, 7 LED indication 3mm, 7 LED indication 8 No. RED LED for
3mm, 3mm, 3mm,
LED Indication : 32 LED indication 32 LED indication 32 LED indication for AL1, AL2,TD1, TD2, for AL1, AL2,TD1, TD2, Alarm Indications of
PRG, TX, RX PRG, TX, RX both set points AL1, AL2

SUPPLY VOLTAGE
230V AC ±10% • 90 to 270VAC
ENVIRONMENTAL
Operating Temp. & Humidity : -20°C to 60°C & Less than 95% Non-Condensing.
HOUSING
Cabinet : Flameproof Weatherproof MS Panel Flameproof MS Panel Weatherproof
Cabinet Material :
ABS Plastic
•Polycarbonate , Grey Colour
•Diecast Aluminium alloy
•Metal sheet Siemens Grey colour
Protection Class :
•IP54 •IP65 • IP66 IP66 IP65 IP54 IP66 IP54 IP65
Enclosure Approval :
•Ex d IIC T6 Gb
•CIMFR Tested /PESO Approved
Dimension : in mm 260(H) x 252(W) x154(D) 182(H) x 214 (W) x 82 (D) 200(H) x 243(W) x 87(D) 357(H) x316(W) x182(D) 300(H)x320(W) x105(D) 317(H) x 365(W) x 160(D)
Cable Entry : 8 8 6 8 10 10
Cable Gland : Double Compression Polyamide Gland Single Compression Double Compression Single Compression Thermoplastic
Mounting : •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand
Weight : 5.5 kg 1kg 2.25 kg. 12 kg 6 kg 2.5 kg

ACCESSORIES (OPTIONAL) : •CE certified 24VDC Power Supply • Hooter cum Flasher •PC based SCADA Software, Modem
•RS-485 to USB Converter •Mounting Stand •Flameproof Hooter •Iot Modules •Cloud : ambeiiot.com

ê Any other requirement please contact us, we can design and built as per your specifications in Flameproof Housing * MS - Mild Steel * FLP - Flameproof Enclosure 8
RANGE OF GAS MONITORS & PANELS
Gas Monitor (8 Channel) Multi Channel Gas Monitor (16 Channel) Multi Channel Gas Monitor Panel

TC-800-FLP TC-800-MS UIP-1600-WP UIP-1600-FLP UIP-1600-MS HMI PANEL-IM-48 RK-220- 8CH. RK-220- 16CH.

0 0

16 CH. 4, 8,16, 48 CH. Individual Channel Individual Channel


8 CH. 8 CH. 16 CH. 16 CH.
8 16,32,48
4-20mA from Gas Transmitter Toxic / Combustible / VOC / IR / UV Flame Detector Etc.
Per Channel Per Channel

2 2 4 4 4 4, 8,16, 24 CH. 4 Per Channel 4 Per Channel

5 5 5 5 5 Setting on HMI Screen 4 4

1 Line x 5 Digit 1 Line x 5 Digit 1 Line x 6 Digit 1 Line x 6 Digit 1 Line x 6 Digit 4.3”, 7”, 10.2” & 15" 3 Digit L.E.D. Display 3 Digit L.E.D. Display
L.E.D. Display L.E.D. Display L.E.D. Display L.E.D. Display L.E.D. Display L.C.D. Display for per card for per card

0 -9999 Programmable 0 to 999 0 to 999


0 to 9999 PPM, % LEL, % V/V PPM, % LEL, % V/V PPM, % LEL, % V/V PPM, % LEL, % V/V

Programmable Programmable Programmable Programmable


Programmable 0.001, 0.01, 0.1, 1 0.001, 0.01, 0.1, 1 0.01, 0.1, 1 0.001, 0.01, 0.1, 1 0.001, 0.01, 0.1, 1

LO/HI, HI/LO, LO/HI, HI/LO,


LO/Very LO, HI-very
HI logic LO/Very LO, HI-very LO/HI, control action for the Alarm 1 & 2 user Programmable LO/HI, HI/LO, LO/Very LO, HI-very HI logic Programmable by user
Programmable HI logic Programmable
by user by user
8 No. RED LED for 8 No. RED LED for 8 No. AL1, AL2, AL3, 16 No. AL1, AL2, AL3,
8/16 Nos. RED LEDs of3mm each for Alarm 1 & 2 Healthy Per channel
Alarm Indications of Alarm Indications of Health Check/Failsafe Health Check/Failsafe
both set points both set points indications for CH-1 to CH-8/CH-1 to CH-16 for indication on HMI Indication PRG, Indication PRG,
AL1, AL2 AL1, AL2 UIP-1600 respectively. CALOptional TX / RX CALOptional TX / RX

230V AC ±10% • 90 to 270VAC


-20°C to 60°C & Less than 95% Non-Condensing.

Flameproof MS Panel Weatherproof Flameproof MS Panel MS Panel MS Panel MS Panel

IP66 IP54 IP65 IP66 IP54 IP54 IP54 IP54

357(H) x316(W)x182(D) 300(H)x320(W)x105(D) 317(H) x 365(W) x 160(D) 448(H)x431(W)x210(D) 300(H)x320(W)x105(D) 600(H)x600(W)x250(D) 600(H)x600(W)x400(D) 800(H)x 600(W)x 400(D)
10 12 17 22 20 as per channel requirement 16 24
Double Compression Single Compression Thermoplastic Double Compression Single Compression Single Compression Single Compression Single Compression
•Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand •Wall •Stand
12 kg 6 kg 2.5 kg 22 kg 6 kg 30 kg 30 kg 34 kg

•CE certified 24VDC Power Supply •Hooter cum Flasher •PC based SCADA Software, Modem •RS-485 to USB Converter
•Mounting Stand •Flameproof Hooter •Iot Modules •Cloud : ambeiiot.com

ê Any other requirement please contact us, we can design and built as per your specifications in Flameproof Housing * WP - Weatherproof Enclosure * HCF - Hooter cum Flasher 9
APPLICATION EXAMPLES
Conventional Multi Channel Oxygen Monitoring System 8 Channel Gas Monitoring System
TC-800-FLP ambeiiot.com
GT-2500-FLP GT-2500-FLP GT-2500-FLP GT-2500-FLP CLOUD MQT T

Detector-1 Detector-2 Detector-7 Detector-8 MQT T Broker


Hooter cum Flasher SMS Alerts

SMS/ E-mail &


Voice call Alerts

SIS4G485
230 VAC
MAIN SUPPLY

3 Core Cable
3 Core 3 Core Cable ( 24VDC, GND, 4-20mA ) RS-485 24V DC
Armoured Shielded Cable
MODBUS RTU

Addressable Multi Channel Oxygen Monitoring System with SMS/ E-mail /Voice call / cloud facility
GT-2500-FLP GT-2500-FLP GT-2500-FLP GT-2500-FLP Multi Channel Gas Monitoring System
Detector-1 Detector-2 Detector-3 Detector-4
ambeiiot.com
CLOUD MQT T

MQT T Broker

SMS/ E-mail & SMS Alerts


Voice call Aler ts

Hooter
JB-1 JB-2 JB-3 JB-20 cum
Flasher
Junction Junction Junction Junction
Box Box Box Box
SIS4G485

4 Core Cable 4 Core Cable 230 VAC


4 Core Cable MAIN SUPPLY
4 Core Armoured Shielded Cable (24VDC GND, D+, D-)
24V DC

Hydrogen Gas Detection System for Battery Room Wireless Gas Detection System
With SMS/E-mail /Voice call / cloud facility with SMS/ E-mail /cloud facility
WGD4MSP WGD2MSB
Hooter Cum Flasher Ventilation Fan
(with Power Contactor )
ambeiiot.com HEALTHY AL1/AL2 COMM

M20
CLOUD MQT T

MQT T Broker
24VDC
Battery Powered
SMS/ E-mail &
SMS Alerts

Voice call Aler ts


Wireless Wireless Gas Detector-2
Gas Detector-1
WGD4MSP
Solar
Powered
SIS4G485 24VDC
HEALTHY AL1/AL2 COMM

CH:01 (Detector-1 ) M20

ST : AL-1:HIGH Solar Powered


PV : +25% LEL
TM : 04/05/19 15:50
Gas Detector
RS-485
LOC : Gate-1
(MODBUS RTU) UID : SIG760389
RSSI : -83

CH:01 (Detector-1 ) HEALTHY AL1/AL2 COMM

ST : OK Wireless SIG4RCV-WP
230 VAC PV : +0% LEL Gas Detector-3
Mains Supply TM : 04/05/19 15:55
LOC : Gate-1
UID : SIG760389 WGD2MSS-FLP
RSSI : -83
• SCADA, E.R.P.
• PLC
Control Room

SMS/ E-mail &


ST : OK ST : AL-2:HIGH Voice call Alerts
GC : 0 %LEL GC : 49 %LEL
SMS Alerts
ETHERNE T/RS-485/RS-232 BT : 100% AL2: 30%LEL
TM : 18:19 BT : 100%
• MODBUS RTU DT : 14 FEB 19 TM : 18:27
• MODBUS TCP-IP UID : 919191 DT : 14 FEB 19
LOC :MUM-ANDI UID : 919191
• MODBUS Over TCP-IP RSSI: -055 LOC :MUM-ANDI
Gas Collection
Cone RSSI: -053

OK SMS Format Alarm SMS Format 10


APPLICATION EXAMPLES
LPG/PNG Gas Leakage System with SMS/E-mail/Voice call/cloud facility for commercial Kitchen
OPTION-1 - Conventional System
GM-416-MS SMS/ E-mail &
3 core cable
Repeater Panel Voice call Aler ts
(24VDC, GND, NO) GM-416-MS

0000 0000
GLA-222-FLP ZONE 1 Ch.01 Ch.01

SIS4G485
Buzzer Buzzer
Cum Cum
3 core cable 230VAC
Flasher
230VAC
Flasher
(24VDC, GND, NO) Mains Supply Mains Supply
RS-485 O/P 24V DC

GLA-222-FLP ZONE 2
OPTION-2 - Addressable System
Hooter cum
Hooter cum MCC-1322-MS Flasher
Flasher SMS/ E-mail &
Voice call Aler ts

GT-4220-FLP GT-4220-FLP SIS4G485

Ring Topology Solenoid Valve


1d
for Fail Safe 81
application LPG Pipeline 24V DC
230VAC RS-485 MODBUS RTU
Relay Module Mains Supply
(REL-1200) Warning Alarm
4 Core Cable
Danger Alarm
( 24VDC, GND, TX, RX (RS-485))

GT-4220-FLP Fault Alarm


GT-4220-FLP

LPG Detector with FTU, Mimic Panel & Smart IoT Gate Way for Bottling Plant (IOCL, BPCL, HPCL)
3 core 1.5 sq.mm cable

•SMS
Control Room
Smart Log software
•E-mail

CIU
Detector-1 Detector-2 >
GT-2511-FLP GT-2511-FLP
>

RS-485 to USB converter


230V AC
Mains Supply

Detector-3 Detector-4 FTU-1 >


GT-2511-FLP GT-2511-FLP

Security Room
>
>
RS-485

MIMIC PANEL (8 ch.)

Detector-5 Detector-6
GT-2511-FLP GT-2511-FLP

230V AC 11
>
>

Mains Supply

> RS-485
Detector-7 Detector-8 230 VAC MAIN SUPPLY
GT-2511-FLP GT-2511-FLP
11
ILLUSTRATIONS
8 CHANNEL GAS MONITORING SYSTEM - WEATHERPROOF - TC-800-WP 8 CHANNEL GAS MONITORING SYSTEM - FLAMEPROOF - TC-800-FLP
Alarm/Hooter with Flasher
Alarm / Hooter
with Flasher

0.00
PPM 0.00
PPM

SMARTLOG SOFTWARE/
RS-485 to USB 230VAC
SCADA SOFTWARE
Converter Mains Supply
230VAC Mains Supply
RS-485 to USB
MAX 1000 METER MAX 1000 METER MAX 1000 METER Converter

Flameproof Gas Detector


4 Core Cable Hooter cum
Hooter cum RS-485 O/P
Flasher Flasher
Weatherproof Flameproof
Hooter cum Hooter
Flasher

OR
16 x 4-20mA Isolated
Retransmission output
for PLC/DCS/Recorder
0.00
PPM Smart IoT Flameproof
Module Weatherproof Gas Detector Junction Box
Max 1000 meter

8x3 core cable RS-232 to


Alarm Alerts on
max 1000 meter USB Converter
Mobile/E-mail
230VAC
RS-485 to Mains Supply
USB Converter Weatherproof
Junction Box RS-485,
4 Core cable RS-485, for SCADA Software
230VAC (1) 24VDC (2) GND Modbus RTU (Optional)
Mains Supply SMARTLOG Software /
2/3 wire transmitter with 4-20mA O/P SCADA Software (3) TX (4) RX 1000 Meter Length

ADDRESSABLE LPG GAS DETECTION SYSTEM WITH REMOTE ALARM & REPEATER PANEL
GD1 GD2 Zone Panel-1 ( MCC-1322-MS) Zone Panel-1 ( MCC-1322-MS) Main Control Room
Zone-1 Hooter
cum Flasher
Hooter
cum Flasher CLOUD MQT T
ambeiiot.com

Buzzer cum
Flasher MQT T Broker

1d
81

Solenoid
Relay Module Valve SMS/ E-mail &
(REL-1200) 230VAC Voice call Aler ts
Mains Supply
4 core cable RS-485 230VAC
RS-485 MODBUS RTU
GD3 GD8 RS-485 ( 24VDC, GND, TX, RX (RS-485)) Mains Supply
Smart IoT System (SIS)
GD1 Zone Panel-1 ( MCC-1322-MS)
Zone-2 GD2
Hooter
cum Flasher JB-400-WP RS-485
Buzzer cum
Flasher MODBUS RTU

Repeater Panel Option-1 Remote Option-2


1d
81
Zone Panel-1 ( MCC-1322-MS-R)
Control Room Hooter cum
Flasher
Solenoid
Relay Module Valve
(REL-1200) Hooter
230VAC cum Flasher
Mains Supply

GD3 GD8 RS-485


4 core cable
( 24VDC, GND, TX, RX (RS-485)) RS-485 OR
Zone Panel-1 ( MCC-1322-MS)
GD1
Zone-3 GD2
Hooter
cum Flasher
Buzzer cum
Flasher
230VAC
230VAC
Mains Supply Option-3
1d
Mains Supply PLC/DCS Panel
81
Warning Alarm
Relay Module
(REL-1200)
Solenoid
Valve
Danger Alarm
OR
230VAC
Mains Supply
4 core cable Fault Alarm
GD3 GD16 RS-485 ( 24VDC, GND, TX, RX (RS-485)) RS-485

AMBETRONICS ENGINEERS PVT. LTD. Follow us on


17-B, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (E.) Mumbai - 400 069, India.
+91-22-61673056 +91-93207 37646 sales8@ambetronics.com
+91-22-61673021/22 +91-91674 18106 sales11@ambetronics.com Version : GAS MASTER CATALOGUE-R13-01112022

You might also like