Professional Documents
Culture Documents
Color Monitor: Service Manual
Color Monitor: Service Manual
Website:http://biz.LGservice.com
E-mail:http://www.LGEservice.com/techsup.html
COLOR MONITOR
SERVICE MANUAL
CHASSIS NO. : LM12E
MODEL: IPS234V (IPS234V-**A)
( ) **Same model for Service
CAUTION
BEFORE SERVICING THE UNIT,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
CONTENTS
SPECIFICATIONS ................................................... 2 ADJUSTMENT ...................................................... 14
PRECAUTIONS ....................................................... 4 TROUBLESHOOTING GUIDE .............................. 16
TIMING CHART ....................................................... 8 WIRING DIAGRAM ............................................... 19
DISASSEMBLY ....................................................... 9 EXPLODED VIEW...................................................20
BLOCK DIAGRAM ................................................. 11 REPLACEMENT PARTS LIST ...............................22
DESCRIPTION OF BLOCK DIAGRAM...................12 SCHEMATIC DIAGRAM ......................................... 26
SPECIFICATIONS
1. LCD CHARACTERISTICS 4. MAX. RESOLUTION
Type : TFT Color LCD Module : 1920 x 1080 @60Hz
Active Display Area : 23 inch diagonal
Pixel Pitch : 0.265 (H) x 0.265 (V)
Size : 533.2(H) x 312(V) x 10.2 (D) 5. POWER SUPPLY
Color Depth : 16.7M colors(6-bit with A-FRC) 5-1. Power Adaptor(Built-in Power)
Electrical Interface : 2ch-LVDS Input : 19 V 1.6 A
Surface Treatment : Anti-Glare, Hard Coating(3H)
Operating Mode : Normally Black 5-2. Power Consumption
Backlight Unit : White LED
MODE H/V SYNC VIDEO POWER CONSUMPTION LED COLOR
less than 33 W(max)
2. OPTICAL CHARACTERISTICS POWER ON (NORMAL) ON/ON ACTIVE RED
2-1. Viewing Angle by Contrast Ratio >10 less than 27 W(typ)
Horizontal: Left:+89°, -89°(Typ) Right: +89°, -89°(Typ) STAND BY OFF/ON OFF less than 0.3 W RED
BLINKING
Vertical: Top:+89°, -89°(Typ) Bottom: +89°, -89°(Typ)
SUSPEND ON/OFF OFF less than 0.3 W RED
2-2. Luminance BLINKING
: 200(min),250(Typ)(Full white pattern,0.70V), DPMS OFF OFF/OFF OFF less than 0.3 W RED
BLINKING
WARM
POWER S/W OFF - - less than 0.3 W OFF
:150(min)(Full whitepattern,0.70V),
MEDIUM Super Energy Saving On/Off On Efficiency: RED
: 150(min)(Full white pattern,0.70V), up to30%
COOL 6. ENVIRONMENT
2-3. Contrast Ratio : 700(min), 1000(TYP) 6-1. Operating Temperature : 10°C~35°C (50°F~95°F)
DFC -> 5000 000 : 1(TYP) 6-2. Relative Humidity : 10%~80% (Non-condensing)
3. SIGNAL (Refer to the Timing Chart)
6-3. MTBF : 30,000 HRS with 90%
3-1. Sync Signal
Confidence level
• Type : Separate Sync, Digital Lamp Life : 30,000 Hours (Min)
3-2. Video Input Signal
7. DIMENSIONS (with TILT)
1) Type : R, G, B Analog
2) Voltage Level : 0~0.7 V
Width : 54.4 cm
3) Input Impedance : 75 Ω
Depth : 40.6 cm
Height : 18.1 cm
3-3. Operating Frequency
Analog/Digital:
Horizontal : 30 ~ 83kHz 8. WEIGHT (with TILT/SWIVEL)
Vertical : 56 ~ 75Hz
Net. Weight : 3.1 kg
HDMI: Gross Weight : 4.4 kg
Horizontal : 30 ~ 83kHz
Vertical : 56 ~ 61Hz
Copyright 2010 LG Electronics. Inc. All right reserved. -2- LGE Internal Use Only
Only for training and service purposes
PRECAUTION
WARNING FOR THE SAFETY-RELATED COMPONENT. WARNING
• There are some special components used in LCD BE CAREFUL ELECTRIC SHOCK !
monitor that are important for safety. These parts are
• If you want to replace with the new backlight (CCFL) or
marked on the schematic diagram and the
inverter circuit, must disconnect the AC adapter
replacement parts list. It is essential that these critical
because high voltage appears at inverter circuit about
parts should be replaced with the manufacturer’s
650Vrms.
specified parts to prevent electric shock, fire or other
hazard.
• Handle with care wires or connectors of the inverter
• Do not modify original design without obtaining written circuit. If the wires are pressed cause short and may
permission from manufacturer or you will void the burn or take fire.
original parts and labor guarantee.
Leakage Current Hot Check Circuit
AC Volt-meter
TAKE CARE DURING HANDLING THE LCD MODULE
WITH BACKLIGHT UNIT.
• Must mount the module using mounting holes arranged
in four corners. Good Earth Ground
such as WATER PIPE,
• Do not press on the panel, edge of the frame strongly CONDUIT etc.
To Instrument's
or electric shock as this will result in damage to the exposed
screen. METALLIC PARTS
CAUTION
Please use only a plastic screwdriver to protect yourself
from shock hazard during service operation.
Copyright 2010 LG Electronics. Inc. All right reserved. -3- LGE Internal Use Only
Only for training and service purposes
SERVICING PRECAUTIONS
CAUTION: Before servicing receivers covered by this 9. Use with this receiver only the test fixtures specified in
service manual and its supplements and addenda, read this service manual.
and follow the SAFETY PRECAUTIONS on page 3 of this CAUTION: Do not connect the test fixture ground strap
publication. to any heat sink in this receiver.
NOTE: If unforeseen circumstances create conflict
between the following servicing precautions and any of the Electrostatically Sensitive (ES) Devices
safety precautions on page 3 of this publication, always Some semiconductor (solid-state) devices can be
follow the safety precautions. Remember: Safety First. damaged easily by static electricity. Such components
commonly are called Electrostatically Sensitive (ES)
General Servicing Precautions Devices. Examples of typical ES devices are integrated
1. Always unplug the receiver AC power cord from the AC circuits and some field-effect transistors and
power source before; semiconductor "chip" components. The following
a. Removing or reinstalling any component, circuit techniques should be used to help reduce the incidence of
board module or any other receiver assembly. component damage caused by static by static electricity.
b. Disconnecting or reconnecting any receiver electrical 1. Immediately before handling any semiconductor
plug or other electrical connection. component or semiconductor-equipped assembly, drain
c. Connecting a test substitute in parallel with an off any electrostatic charge on your body by touching a
electrolytic capacitor in the receiver. known earth ground. Alternatively, obtain and wear a
CAUTION: A wrong part substitution or incorrect commercially available discharging wrist strap device,
polarity installation of electrolytic capacitors may which should be removed to prevent potential shock
result in an explosion hazard. reasons prior to applying power to the unit under test.
d. Discharging the picture tube anode. 2. After removing an electrical assembly equipped with
2. Test high voltage only by measuring it with an ES devices, place the assembly on a conductive
appropriate high voltage meter or other voltage surface such as aluminum foil, to prevent electrostatic
measuring device (DVM, FETVOM, etc) equipped with charge buildup or exposure of the assembly.
a suitable high voltage probe. 3. Use only a grounded-tip soldering iron to solder or
Do not test high voltage by "drawing an arc". unsolder ES devices.
3. Discharge the picture tube anode only by (a) first 4. Use only an anti-static type solder removal device.
connecting one end of an insulated clip lead to the Some solder removal devices not classified as "anti-
degaussing or kine aquadag grounding system shield static" can generate electrical charges sufficient to
at the point where the picture tube socket ground lead damage ES devices.
is connected, and then (b) touch the other end of the 5. Do not use freon-propelled chemicals. These can
insulated clip lead to the picture tube anode button, generate electrical charges sufficient to damage ES
using an insulating handle to avoid personal contact devices.
with high voltage. 6. Do not remove a replacement ES device from its
4. Do not spray chemicals on or near this receiver or any protective package until immediately before you are
of its assemblies. ready to install it. (Most replacement ES devices are
5. Unless specified otherwise in this service manual, packaged with leads electrically shorted together by
clean electrical contacts only by applying the following conductive foam, aluminum foil or comparable
mixture to the contacts with a pipe cleaner, cotton- conductive material).
tipped stick or comparable non-abrasive applicator; 7. Immediately before removing the protective material
10% (by volume) Acetone and 90% (by volume) from the leads of a replacement ES device, touch the
isopropyl alcohol (90%-99% strength) protective material to the chassis or circuit assembly
CAUTION: This is a flammable mixture. into which the device will be installed.
Unless specified otherwise in this service manual, CAUTION: Be sure no power is applied to the chassis
lubrication of contacts in not required. or circuit, and observe all other safety precautions.
6. Do not defeat any plug/socket B+ voltage interlocks 8. Minimize bodily motions when handling unpackaged
with which receivers covered by this service manual replacement ES devices. (Otherwise harmless motion
might be equipped. such as the brushing together of your clothes fabric or
7. Do not apply AC power to this instrument and/or any of the lifting of your foot from a carpeted floor can
its electrical assemblies unless all solid-state device generate static electricity sufficient to damage an ES
heat sinks are correctly installed. device.)
8. Always connect the test receiver ground lead to the
receiver chassis ground before connecting the test
receiver positive lead.
Always remove the test receiver ground lead last.
Video
B
C
Sync
D E F
A
#2
Remove the stand body and atand base from the product.
#3
#4
LED Panel
23’’Inch
2. Power Part.
This part consists of one regulator convert power from 19V to 5V.19V is provided by adapter.
5V is provided for LCD panel .
Also, 5V is converted 3.3V by regulator.Converted Power is provided for IC in the main board.
Boost converter of LED block converters 19V to 53.6V and operates back-light LED strings of module in
IPS234V case.
3. MICOM Part.
This part is include video controller part. And this part consists of Flash IC which stores control data and the Micom.
The Micom distinguishes polarity and frequency of the H/V sync are supplied from signal cable.
The controlled data of each modes is stored in.
30~60V
20V
50 ~ 60Hz LED
drive
HVDC KHz 5V block
EMI INPUT RECTIFIER ENERGY OUTPUT RECTIFIER
COMPONENTS AND FILTER TRANSFER AND FILTER
LINE GND
100 ~ 240V
PHOTO- SIGNAL
PWM
COUPLER Collection
CONTROL
CIRCUIT ISOLATION ,21
PRIMARY SECONDARY
Operation description_Power
1. EMI components.
This part contains of EMI components to comply with global marketing EMI standards like FCC,VCCI CISPR, the
circuit included a line-filter, across line capacitor and of course the primary protection fuse.
3. Energy Transfer.
This part function is for transfer the primary energy to secondary through a power transformer.
5. Photo-Coupler isolation.
This part function is to feed back the DC output changing status through a photo transistor to primary controller to
achieve the stabilized DC output voltage.
6. Signal collection.
This part function is to collect the any change from the DC output and feed back to the primary through photo
transistor.
1. Port Setup
a) Copy “UserPort.sys” file to
“c:\WINNT\system32\drivers” folder
b) Run Userport.exe
2) Wait for about 5 seconds and press MENU, POWER switch for 1 second interval.
3) The SVC OSD menu contains additional menus that the User OSD menu as described below.
IBM 9 6
Video Signal 5 1
Compatible PC 15 11
Generator 10 6
5 1
C
PARALLEL PORT
d
13
se
1
tu
2C
25
No
14
23
RS
OFF ON
5V
EL
Control Line
F
LL
C
RA
PA
VG ON
WE
S 5V
(110V/220V)
PO
E 74LS06
A
T
MO Power LED
CS
NI OFF 4.7K
YN
TO
V-S
R
74LS06
E ST Switch
B
B
F V-Sync On/Off Switch
(Switch must be ON.)
NO POWER
(POWER INDICATOR OFF)
IS ADAPTER NO
1 VOLTAGE 19V? CHECK Adapter
YES
2 NO
IS IC102 PIN 3(5V)? CHECK IC102(5V)
3
1
YES
YES
YES
CHECK IC101
Waveforms
1 JK100#1 2 IC102#3 3 IC102#1 4 IC104#42,43
1.2V
NO RASTER
(OSD IS NOT DISPLAYED)
YES
YES
TROUBLE IN CABLE
OR LCD MODULE
Copyright 2010 LG Electronics. Inc. All right reserved. - 15 - LGE Internal Use Only
Only for training and service purposes
3. TROUBLE IN DPM
TROUBLE IN DPM
YES
YES
TROUBLE IN IC101
Waveforms
1 H-SYNC 2 V-SYNC
Copyright 2010 LG Electronics. Inc. All right reserved. - 16 - LGE Internal Use Only
Only for training and service purposes
WIRING DIAGRAM
EAD61905271
6631900011S
500
520 510
200
410
530
or
540 900
MARCH.2012
P/NO : MFL66100842 Printed in China