Primary samplers for pressure flow
A PSA pressure pipe sampler with an optional ASA sector samplers are used to divide
automatic VSA valve set for flushing. PSA small pressure flows. A sector sampler can
samplers are typically used at pump outlets. be delivered to take 25, 50 or 75 % of the
process flow.
SPSA straight pressure pipe sampler. Where A SPA suction pipe sampler for sampling a
it is inconvenient to use a PSA sampler in flotation cell discharge box, with an automatic
conventional vertical position. VSA valve set for flushing.
Process location Flow-rate Pipe size Sampler type Note Sample use
After pump or > 600 l/min >100 mm PSA pressure pipe sampler Analysis
long vertical pipe (or SPSA) Composite
After pump or < 600 l/min ≤100 mm ASA sector sampler Can take 25, 50 or 75 % Analysis
long vertical pipe of flow Composite
Horizontal pipe, > 500 l/min >100 mm SPSA straight pressure pipe Can also be used for Analysis
no froth sampler vertical pipes
Horizontal pipe < 500 l/min ≤100 mm HCS sector sampler Can split sample Analysis
between analyzers Composite
Flotation cell All N/A SPA suction pipe sampler Analysis
discharge box
3
Primary samplers for gravity flow
Process location Flow-rate m³/h Pipe size Sampler Note Sample use
Nearly horizontal 25–1000–(1600) ≤600 mm LSA or NLA vertical cutter Flow >1000 m³/h Analysis
gravity pipe sampler requires a partly Composite
blanked cutter Accounting
Gravity flow in <1000–2000 N/A SKA vertical sample cutter Analysis
launder Composite
Accounting
Nearly horizontal >500 N/A TSC two stage vertical Two Stage Cutter Analysis
gravity flow cutter sampler allows broader cutter Composite
opening than LSA/NLA
Nearly horizontal >350 ≥250 mm CPS primary sampler Two stage sampler. Analysis
gravity pipe or Requires control from Composite
launder, no froth analyzer. Restricted
sample flow.
Horizontal pipe < 30 ≤100 mm HCS sector sampler Can split sample Analysis
or LSA 80 between analyzers Composite
Accounting
ASD 50 adjustable sample
Sample line 6–18 50 mm Reduces primary Analysis
divider
sample flow and splits Composite
sample Accounting
4
Sample flow from vertical cutters should not
be restricted.
A SKA vertical cutter sampler for process An ASD adjustable sample divider located
flows under ambient pressure in a launder. on top of a PSI 500™ analyzer multiplexer,
allowing a large primary sample flow to be
used for easily settling slurry.
A TSC two stage vertical cutter sampler for A CPS two stage sampler for high speed
large process flows under ambient pressure. process flows. The sample entering the tube
The sampler can be installed at a launder is re-sampled using a controlled syphon
bottom or in a LSA style sampling box. sampler.
5
Metallurgical accounting sampling
MSA Multi-stage
Metallurgical Accounting
Sampler
Operation of the sampler is based on a
combination of static multiple cutter
stages (depending on the process flow),
followed by a moving crosscut sampler
stage, which produces the sample. The
MSA samplers can handle process flows
from 60–18,000 m³/h. A MSA 1/40 metallurgical sampler.
The MSA sampler can be configured
to deliver a composite sample or a
continuous flow of about 150 l/min, Model Nominal Stages Number Main Sample use
which is suitable for Courier® and PSI™ capacity m³/h of static launder
cutters width mm
analyzers. Analyzer controlled sampling by
MSA 1/40 60–180 1 none 400 Analysis
the MSA samplers is also possible. Composite
Accounting
MSA 2/50 180–600 2 3 500 Analysis
Composite
Accounting
Composite sampling
and filtering
The final composite sample is taken from
the 150 l/min primary sample flow by the
secondary sampler in a Courier® on-stream
analyzer system (see figure on left) or a
PSI™ particle size analyzer. A SSA
composite sampler can be used to collect
composite sample after primary sampler
instead of an on-stream analyzer.
The composite sample can be filtered
using an optional VFU vacuum sample
filter unit. The VFU is self-contained,
equipped with a vacuum blower and
uses standard filter papers.
A composite sampler SSA 50 with sample filter
Composite sampling by a Courier® analyzer and vacuum blower to sample 50–400 l/min
multiplexer. flow.
6
Controlled sampling
Options
On-demand sampling
Flanges: DIN 2576, AS 2129–TABLE D, SABS 1123–TABLE 10,
The primary sample is controlled so that it ANSI B16.5–150 lbs, Victaulic
only flows when required for measurement
Lining: Natural rubber as standard other materials as an option
and/or composite sampling. When the
Cutters: Wear areas rubber lined, hard metals and ceramics as options
sample flow is stopped after measurement
Sample valves: Manual and automatic flush valves are available
or composite sampling, the delivery line is
flushed with water. This radically improves
the availability of samples and reduces
return pump volumes. Sampling, sample presentation and
patent applications are covered by
several patents owned by Outokumpu
Automatically flushed
Technology Oy.
sample lines
The primary sample usually flows Courier® is a registered trademark of
continuously but is interrupted at Outokumpu Technology Oy.
composite sampling.