You are on page 1of 91

DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

PROJECT ONE – ECR EPCM SERVICES CONTRACT

7650-8550-DS-500-6105

LEVEL INSTRUMENTS DATASHEETS


RADAR LEVEL TRANSMITTER DATASHEETS - AREA OF PAU-002 (P2)

EE1 27-Dec-2022 FE FOR ENQUIRY AS PHC SCA

Rev.No. Date Issue Code Description Prepared by Reviewed by Approved by

© All rights reserved. This document is protected by copyright. The contents and information in this document, in particular text, drawings and images it contains, are
strictly confidential and may not be altered or amended, copied, used or disclosed without the express permission of the rights holder.
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

CLIENT
LOGO Project One – ECR EPCm

PROJECT No.: 10420


PAGE 2 of 95

INDEX

ITEM TAG NUMBER REVISION STATUS PAGE

1 ECR-LT -20501A EE1 RFI 4


2 ECR-LT -20501B EE1 RFI 6
3 ECR-LT -20501C EE1 RFI 8
4 ECR-LT -20102A EE1 RFI 10
5 ECR-LT -20102B EE1 RFI 12
6 ECR-LT -20102C EE1 RFI 14
7 ECR-LT -20503A EE1 RFI 16
8 ECR-LT -20503B EE1 RFI 18
9 ECR-LT -20601A EE1 RFI 20
10 ECR-LT -20601B EE1 RFI 22
11 ECR-LT -20604A EE1 RFI 24
12 ECR-LT -20604B EE1 RFI 26
13 ECR-LT -20703A EE1 RFI 28
14 ECR-LT -20703B EE1 RFI 30
15 ECR-LT -20706A EE1 RFI 32
16 ECR-LT -20706B EE1 RFI 34
17 ECR-LT -20901A EE1 RFI 36
18 ECR-LT -20901B EE1 RFI 38
19 ECR-LT -20904 EE1 RFI 40
20 ECR-LT -20911 EE1 RFI 42
21 ECR-LT -22102A EE1 RFI 44
22 ECR-LT -22102B EE1 RFI 46
23 ECR-LT -22302A EE1 RFI 48
24 ECR-LT -22302B EE1 RFI 50
25 ECR-LT -22303A EE1 RFI 52
26 ECR-LT -22303B EE1 RFI 54
27 ECR-LT -22403A EE1 RFI 56
28 ECR-LT -22403B EE1 RFI 58
29 ECR-LT -22802A EE1 RFI 60
30 ECR-LT -22802B EE1 RFI 62
31 ECR-LT -22902A EE1 RFI 64
32 ECR-LT -22902B EE1 RFI 66
33 ECR-LT -22903A EE1 RFI 68
34 ECR-LT -22903B EE1 RFI 70
35 ECR-LT -88301A EE1 RFI 72
36 ECR-LT -88301B EE1 RFI 74
37 ECR-LT -88407A EE1 RFI 76
38 ECR-LT -88407B EE1 RFI 78
39 ECR-LT -89201A EE1 RFI 80
40 ECR-LT -92166 EE1 RFI 82
41 ECR-LZT -10351A EE1 RFI 84
42 ECR-LZT -10351B EE1 RFI 86
43 ECR-LZT -10351C EE1 RFI 88
44 ECR-LT -10354 EE1 RFI 90

© All rights reserved. This document is protected by copyright. The contents and information in this document, in particular text, drawings and images it contains,
are strictly confidential and may not be altered or amended, copied, used or disclosed without the express permission of the rights holder.
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
GENERAL NOTES:

1- VTA: Vendor to Advise.


2- Spare Cable entries shall be plugged with brass screw plug. Cable gland entry shall be supplied with plastic plug
3- Positive Material Identification (PMI) shall be done for pressure containing housing as per INEOS specification
4- Transmitter shall have HART Protocol version 7 with sensor fault indication to NAMUR NE 43. Hart tag number shall be configured in
Manufacturing
5- Burn out direction shall be specified in EPC stage based on process requirements.
6- Transmitter self?monitoring and diagnostics shall be in accordance to NAMUR NE 107.
7- Instrument casings, enclosures and housings shall be anodised aluminium and suitably painted for the environmental conditions.
8- Vendor to provide all applicable testing certificates such as Calibration certificate, Hydrotest, Radiography, Dye penetration test , Intergranular
Corrosion test, etc.
9- Values for Dielectric Constant are on HOLD.
10- Centering Ring / Counterweight shall be provided by Vendor.
11- SIL certificates with failure rates as per IEC 61508 ed. 2010 shall be provided.
12- Material Certificate: EN 10204 3.1 for pressure retaining part.
13- Vendor to provide all applicable testing certificate such as Calibration certificate, Hydrotest, Radiography, PMI test, DP test, Intergranular
corrosion test, etc
14- The meter electronics shall be protected against transients induced by lightning and power supply surges. Transient protection electronics shall
preferably be provided in the terminal block. The transient protection shall meet the requirements specified in IEC-60587.

Domain: INEOS_ECR Plant: ECR_P


Area: ECR Unit: 20

Binder Package
General Notes
Template: P2
7650-8550-DS-500-6105, RADAR
EE1 AS 27/12/2022 FOR ENQUIRY LEVEL TRANSMITTER Page N-1 of 1
No. By Date Description Doc. No.: DATASHEETS - ARE Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20501A 61 Plant ECR_P
3 Service DS2050 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2011 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 4410 - 5140 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 730 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Tar/Pyrolysis Oil 93 NACE Requirements N/A
35 Upper Fluid Name TARS/PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 85 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1086 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -0,5 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-1.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20501A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20501A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter
5. INTERFACE LEVEL TRANSMITTERS LDT-20501A/B/C TO BE CONFIGURED AS ABSOLUTE LEVEL TRANSMITTERS FOR DS-2050
FILLING DURING START-UP

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-1.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20501A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20501B 61 Plant ECR_P
3 Service DS2050 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2011 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 4410 - 5140 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 730 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Tar/Pyrolysis Oil 93 NACE Requirements N/A
35 Upper Fluid Name TARS/PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 85 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1086 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -0,5 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-2.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20501B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20501B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter
5. INTERFACE LEVEL TRANSMITTERS LDT-20501A/B/C TO BE CONFIGURED AS ABSOLUTE LEVEL TRANSMITTERS FOR DS-2050
FILLING DURING START-UP

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-2.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20501B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20501C 61 Plant ECR_P
3 Service DS2050 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2011 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 4410 - 5140 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 730 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Tar/Pyrolysis Oil 93 NACE Requirements N/A
35 Upper Fluid Name TARS/PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 85 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1086 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -0,5 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-3.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20501C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20501C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter
5. INTERFACE LEVEL TRANSMITTERS LDT-20501A/B/C TO BE CONFIGURED AS ABSOLUTE LEVEL TRANSMITTERS FOR DS-2050
FILLING DURING START-UP

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-3.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20501C Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20102A 61 Plant ECR_P
3 Service T2010 Quench Water Lvl 62 Unit 20
4 Equipment ECR-T-2010 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 170 - 1470 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1300 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 970,1 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 3,5 104
46 Design Temperature Min/Max °C -18,3 250 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-4.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20102A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20102A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@3.5 barg and 125 deg C@-0.5 barg
3. GWR Level trnasmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-4.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20102A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20102B 61 Plant ECR_P
3 Service T2010 Quench Water Lvl 62 Unit 20
4 Equipment ECR-T-2010 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 170 - 1470 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1300 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 970,1 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 3,5 104
46 Design Temperature Min/Max °C -18,3 250 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-5.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20102B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20102B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@3.5 barg and 125 deg C@-0.5 barg
3. GWR Level trnasmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-5.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20102B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20102C 61 Plant ECR_P
3 Service T2010 Quench Water Lvl 62 Unit 20
4 Equipment ECR-T-2010 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 170 - 1470 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1300 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 970,1 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 3,5 104
46 Design Temperature Min/Max °C -18,3 250 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-6.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20102C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20102C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@3.5 barg and 125 deg C@-0.5 barg
3. GWR Level trnasmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-6.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20102C Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20503A 61 Plant ECR_P
3 Service DS2050 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2011 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 210 - 780 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 570 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Quench Water 93 NACE Requirements N/A
35 Upper Fluid Name Quench Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 82 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 968,2 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg -0,5 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-7.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20503A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20503A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-7.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20503A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20503B 61 Plant ECR_P
3 Service DS2050 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2011 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 210 - 780 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 570 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Quench Water 93 NACE Requirements N/A
35 Upper Fluid Name QUENCH WATER 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 82 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 968,2 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg -0,5 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-8.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20503B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20503B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-8.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20503B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20601A 61 Plant ECR_P
3 Service DS2060 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2060 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2017 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 200 - 1900 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1700 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Light Hydrocarbons 93 NACE Requirements N/A
35 Upper Fluid Name Light Hydrocarbons 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 9 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 889,4 99 Fire Safe Design N/A
41 Upper Density kg/m³ 929,6 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-9.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20601A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20601A

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-9.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20601A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20601B 61 Plant ECR_P
3 Service DS2060 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2060 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2017 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 200 - 1900 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1700 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Light Hydrocarbons 93 NACE Requirements N/A
35 Upper Fluid Name Light Hydrocarbons 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 9 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 889,4 99 Fire Safe Design N/A
41 Upper Density kg/m³ 929,6 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-10.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20601B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20601B

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-10.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20601B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20604A 61 Plant ECR_P
3 Service DS2060 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2060 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2017 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 210 - 790 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 580 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Process Water 93 NACE Requirements N/A
35 Upper Fluid Name Process Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 9 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 969,3 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-11.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20604A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20604A

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-11.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20604A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20604B 61 Plant ECR_P
3 Service DS2060 Oil/Water Lvl 62 Unit 20
4 Equipment ECR-DS-2060 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2017 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 210 - 790 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 580 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Process Water 93 NACE Requirements N/A
35 Upper Fluid Name Process Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 9 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 969,3 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-12.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20604B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20604B

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-12.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20604B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20703A 61 Plant ECR_P
3 Service DS2070A Sour Water Lvl 62 Unit 20
4 Equipment ECR-DS-2070A 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2021 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 50 - 850 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 800 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Sour Water 93 NACE Requirements N/A
35 Upper Fluid Name Sour Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 8,8 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 961,5 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-13.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20703A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20703A

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-13.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20703A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20703B 61 Plant ECR_P
3 Service DS2070A Sour Water Lvl 62 Unit 20
4 Equipment ECR-DS-2070A 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2021 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 50 - 850 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 800 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Sour Water 93 NACE Requirements N/A
35 Upper Fluid Name Sour Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 8,8 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 961,5 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-14.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20703B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20703B

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-14.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20703B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20706A 61 Plant ECR_P
3 Service DS2070B Sour Water Lvl 62 Unit 20
4 Equipment ECR-DS-2070B 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2021 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 50 - 850 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 800 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Sour Water 93 NACE Requirements N/A
35 Upper Fluid Name Sour Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 8,8 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 961,5 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-15.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20706A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20706A

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-15.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20706A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20706B 61 Plant ECR_P
3 Service DS2070B Sour Water Lvl 62 Unit 20
4 Equipment ECR-DS-2070B 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2021 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 50 - 850 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 800 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Sour Water 93 NACE Requirements N/A
35 Upper Fluid Name Sour Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 8,8 97 Test Requirements See Notes
39 Temperature °C 84 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 961,5 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,32 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-16.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20706B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20706B

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vaccuum conditions
4. Electrical Tracing Temperature: 5°C

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-16.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20706B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20901A 61 Plant ECR_P
3 Service DS2090 Tar/Oil Lvl 62 Unit 20
4 Equipment ECR-DS-2090 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2015 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 5700 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Quench Water 90 NACE Requirements N/A
32 Upper Fluid Name Quench Water 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Liquid 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 3,5 94 Test Requirements See Notes
36 Temperature °C 83 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 962,7 96 Fire Safe Design N/A
38 Upper Density kg/m³ 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 Upper Specific Gravity 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 7 101
43 Design Temperature Min/Max °C -18,3 150 102
44 Dielectric Constant Upper/Lower 1,84 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-17.1 of 88
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-20901A Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20901A

Process Notes:

1. PED classification fluid state/group-G/1


2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vacuum conditions
4. Radar Level Transmitter

Instrument Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-17.2 of 88


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-20901A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20901B 61 Plant ECR_P
3 Service DS2090 Tar/Oil Lvl 62 Unit 20
4 Equipment ECR-DS-2090 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2015 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 5700 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Quench Water 90 NACE Requirements N/A
32 Upper Fluid Name Quench Water 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Liquid 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 3,5 94 Test Requirements See Notes
36 Temperature °C 83 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 962,7 96 Fire Safe Design N/A
38 Upper Density kg/m³ 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 Upper Specific Gravity 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 7 101
43 Design Temperature Min/Max °C -18,3 150 102
44 Dielectric Constant Upper/Lower 1,84 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-18.1 of 88
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-20901B Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20901B

Process Notes:

1. PED classification fluid state/group-G/1


2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vacuum conditions
4. Radar Level Transmitter

Instrument Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-18.2 of 88


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-20901B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20904 61 Plant ECR_P
3 Service DS2090 Tar/Oil Lvl 62 Unit 20
4 Equipment ECR-DS-2090 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2015 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting Top Side Down Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm - 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Quench Water+Tars/Coke/Oil 93 NACE Requirements N/A
35 Upper Fluid Name Quench water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3,5 97 Test Requirements See Notes
39 Temperature °C 83 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1120 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 7 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-19.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20904 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20904

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-19.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20904 Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -20911 61 Plant ECR_P
3 Service DS2090 Tar/Oil Lvl 62 Unit 20
4 Equipment ECR-DS-2090 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-520-2015 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Flexible Single Rod 69 Mounting Top Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 5700 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Quench Water 93 NACE Requirements N/A
35 Upper Fluid Name Quench water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3,5 97 Test Requirements See Notes
39 Temperature °C 83 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 962,7 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 7 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-20.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-20911 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -20911

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg
3. Instrument shall be designed for full vacuum condition.
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-20.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-20911 Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22102A 61 Plant ECR_P
3 Service DS2210 Tar/Oil Disposal Sep Lvl 62 Unit 22
4 Equipment ECR-DS-2210 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 5700 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name H2O / TARS / COKE / PYROLYSIS OIL
90 NACE Requirements N/A
32 Upper Fluid Name H2O / TARS / COKE / PYROLYSIS OIL
91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Liquid 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0,6 94 Test Requirements See Notes
36 Temperature °C 80,4 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 890,1 96 Fire Safe Design N/A
38 Upper Density kg/m³ 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 Upper Specific Gravity 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 7 101
43 Design Temperature Min/Max °C -18,3 150 102
44 Dielectric Constant Upper/Lower 1,84 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-21.1 of 88
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-22102A Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22102A

Process Notes:

1. PED classification fluid state/group-G/1


2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition
4. Radar Level Transmitter
5. Coke solid: 10-200 microns

Instrument Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-21.2 of 88


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-22102A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22102B 61 Plant ECR_P
3 Service DS2210 Tar/Oil Disposal Sep Lvl 62 Unit 22
4 Equipment ECR-DS-2210 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 5700 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name H2O / TARS / COKE / PYROLYSIS OIL
90 NACE Requirements N/A
32 Upper Fluid Name H2O / TARS / COKE / PYROLYSIS OIL
91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Liquid 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0,6 94 Test Requirements See Notes
36 Temperature °C 80,4 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 971 96 Fire Safe Design N/A
38 Upper Density kg/m³ 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 Upper Specific Gravity 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 7 101
43 Design Temperature Min/Max °C -18,3 150 102
44 Dielectric Constant Upper/Lower 1,84 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-22.1 of 88
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-22102B Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22102B

Process Notes:

1. PED classification fluid state/group-G/1


2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Instrument shall be designed for full vacuum condition
4. Radar Level Transmitter
5. Coke solid: 10-200 microns

Instrument Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-22.2 of 88


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-22102B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22302A 61 Plant ECR_P
3 Service DS2230 Oil/Water Sep Lvl 62 Unit 22
4 Equipment ECR-DS-2230 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2004 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 600 - 2620 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2020 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name TARS / PYROLYSIS OIL+H2O 93 NACE Requirements N/A
35 Upper Fluid Name TARS / PYROLYSIS OIL+H2O 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,4 97 Test Requirements See Notes
39 Temperature °C 72,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 929 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-23.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22302A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22302A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-23.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22302A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22302B 61 Plant ECR_P
3 Service DS2230 Oil/Water Sep Lvl 62 Unit 22
4 Equipment ECR-DS-2230 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2004 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 600 - 2620 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2020 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name TARS / PYROLYSIS OIL+H2O 93 NACE Requirements N/A
35 Upper Fluid Name TARS / PYROLYSIS OIL+H2O 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,4 97 Test Requirements See Notes
39 Temperature °C 72,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 929 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-24.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22302B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22302B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-24.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22302B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22303A 61 Plant ECR_P
3 Service DS2230 Oil/Water Sep Lvl 62 Unit 22
4 Equipment ECR-DS-2230 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2004 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 250 - 2620 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2370 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name TARS / PYROLYSIS OIL+H2O 93 NACE Requirements N/A
35 Upper Fluid Name TARS / PYROLYSIS OIL+H2O 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,4 97 Test Requirements See Notes
39 Temperature °C 72,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 970 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-25.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22303A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22303A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-25.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22303A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22303B 61 Plant ECR_P
3 Service DS2230 Oil/Water Sep Lvl 62 Unit 22
4 Equipment ECR-DS-2230 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2004 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 250 - 2620 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2370 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name TARS / PYROLYSIS OIL+H2O 93 NACE Requirements N/A
35 Upper Fluid Name TARS / PYROLYSIS OIL+H2O 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,4 97 Test Requirements See Notes
39 Temperature °C 72,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 970 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 15,8 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-26.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22303B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22303B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-26.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22303B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22403A 61 Plant ECR_P
3 Service D2240 Flushing Pygas Drum Lvl 62 Unit 22
4 Equipment ECR-D-2240 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2007 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 200 - 1800 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1600 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name RAW PYROLYSIS GASOLINE / Wash
93 Oil
NACE Requirements N/A
35 Upper Fluid Name RAW PYROLYSIS GASOLINE / Wash
94 Oil
Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 35,3 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 833,6 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,26 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-27.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22403A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22403A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-27.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22403A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22403B 61 Plant ECR_P
3 Service D2240 Flushing Pygas Drum Lvl 62 Unit 22
4 Equipment ECR-D-2240 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2007 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 200 - 1800 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1600 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name RAW PYROLYSIS GASOLINE / Wash
93 Oil
NACE Requirements N/A
35 Upper Fluid Name RAW PYROLYSIS GASOLINE / Wash
94 Oil
Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 35,3 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 833,6 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 3,6 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,26 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-28.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22403B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22403B

Process notes:

1. PED classification fluid state/group-G/1


2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-28.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22403B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22802A 61 Plant ECR_P
3 Service DS2280 Pygas Coalescer Lvl 62 Unit 22
4 Equipment ECR-DS-2280 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2015 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 150 - 1000 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 850 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name SOUR WATER 93 NACE Requirements N/A
35 Upper Fluid Name SOUR WATER 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 4 97 Test Requirements See Notes
39 Temperature °C 35,6 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 844,9 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 13 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,292 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-29.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22802A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22802A

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions 125 deg C@FV & 210 deg C@7 barg
3. Electrical Tracing Temperature: 5°C
4. Instrument shall be designed for full vacuum conditions
5. GWR Level Transmitter.

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTMA193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-29.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22802A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22802B 61 Plant ECR_P
3 Service DS2280 Pygas Coalescer Lvl 62 Unit 22
4 Equipment ECR-DS-2280 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2015 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 150 - 1000 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 850 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name SOUR WATER 93 NACE Requirements N/A
35 Upper Fluid Name SOUR WATER 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 4 97 Test Requirements See Notes
39 Temperature °C 35,6 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 844,9 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 13 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,292 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-30.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22802B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22802B

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions 125 deg C@FV & 210 deg C@7 barg
3. Electrical Tracing Temperature: 5°C
4. Instrument shall be designed for full vacuum conditions
5. GWR Level Transmitter.

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTMA193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-30.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22802B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22902A 61 Plant ECR_P
3 Service DS2260 Pyoil Vac Pkg Cnd Drm Lvl 62 Unit 22
4 Equipment ECR-DS-2260 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2012 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 200 - 1730 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1530 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name STEAM CONDENSATE 93 NACE Requirements N/A
35 Upper Fluid Name PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 35,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 999,8 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,292 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower Yes Yes 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-31.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22902A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22902A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions- 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5ºC
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-31.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22902A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22902B 61 Plant ECR_P
3 Service DS2260 Pyoil Vac Pkg Cnd Drm Lvl 62 Unit 22
4 Equipment ECR-DS-2260 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2012 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 200 - 1730 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1530 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name STEAM CONDENSATE 93 NACE Requirements N/A
35 Upper Fluid Name PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 35,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 999,8 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,292 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower Yes Yes 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-32.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22902B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22902B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions- 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5ºC
4. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-32.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22902B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22903A 61 Plant ECR_P
3 Service DS2260 Pyoil Vac Pkg Cnd Drm Lvl 62 Unit 22
4 Equipment ECR-DS-2260 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2012 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 200 - 1730 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1530 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name STEAM CONDENSATE 93 NACE Requirements N/A
35 Upper Fluid Name PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 35,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 999,8 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,26 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-33.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22903A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22903A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions- 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-33.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22903A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -22903B 61 Plant ECR_P
3 Service DS2260 Pyoil Vac Pkg Cnd Drm Lvl 62 Unit 22
4 Equipment ECR-DS-2260 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AV 64 Location EQUIP
6 P&ID No. 7650-8110-25-522-2012 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 200 - 1730 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1530 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name STEAM CONDENSATE 93 NACE Requirements N/A
35 Upper Fluid Name PYROLYSIS OIL 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 35,1 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 999,8 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 150 105
47 Dielectric Constant Upper/Lower 2,6 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-34.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-22903B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -22903B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions- 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-34.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-22903B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -88301A 61 Plant ECR_P
3 Service Transformer Oil Pit UGP8830 Lvl 62 Unit 88
4 Equipment ECR-UGP-8830 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AW 64 Location EQUIP
6 P&ID No. 7650-8110-25-588-2013 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type 69 Mounting Top Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm 3" Sch STD N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Waste Water 93 NACE Requirements N/A
35 Upper Fluid Name Air 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 0 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No Yes 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-35.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-88301A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -88301A

PROCESS NOTES:

1. PED classification: Fluid State: L / Group: 1


2. Transformer Oil Pit (ECR-UGP-8830), with 3.5 m of deep. Dimensions to be confirmed.
3. Level alarms will be confirmed after finalizing pit design.

INSTRUMENT NOTES:
I-1. Gasket Materials: Synthetic Fibre With Oil Resistant Binder.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-35.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-88301A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -88301B 61 Plant ECR_P
3 Service Transformer Oil Pit UGP8830 Lvl 62 Unit 88
4 Equipment ECR-UGP-8830 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AW 64 Location EQUIP
6 P&ID No. 7650-8110-25-588-2013 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type 69 Mounting Top Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm 3" Sch STD N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Waste Water 93 NACE Requirements N/A
35 Upper Fluid Name Air 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 0 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No Yes 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-36.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-88301B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -88301B

PROCESS NOTES:

1. PED classification: Fluid State: L / Group: 1


2. Transformer Oil Pit (ECR-UGP-8830), with 3.5 m of deep. Dimensions to be confirmed.
3. Level alarms will be confirmed after finalizing pit design.

INSTRUMENT NOTES:
I-1. Gasket Materials: Synthetic Fibre With Oil Resistant Binder.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-36.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-88301B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -88407A 61 Plant ECR_P
3 Service UGP8840 Lvl 62 Unit 88
4 Equipment ECR-UGP-8840 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AW 64 Location EQUIP
6 P&ID No. 7650-8110-25-588-2015 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type 69 Mounting Top Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm 3" Sch STD N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Waste Water 93 NACE Requirements N/A
35 Upper Fluid Name Air 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 0 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No Yes 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-37.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-88407A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -88407A

PROCESS NOTES:
1. PED classification: Fluid State: L / Group: 1
2. DCC Collection Pit (ECR-UGP-8840), with 3.5 m of deep. Dimensions to be confirmed.
3. High level switch will activate UC-88001 (Pump shall start).
4. Low level switch will activate UC-89002 (Pump shall stop).
5. Low Level height must be updated once the VENDOR confirms minimum submergence level of the pump and the dimensions of the pit has been
established..
6. Level alarms will be confirmed after finalizing pit design.

INSTRUMENT NOTES:
I-1. Gasket Materials: Synthetic Fibre With Oil Resistant Binder.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-37.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-88407A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -88407B 61 Plant ECR_P
3 Service UGP8840 Lvl 62 Unit 88
4 Equipment ECR-UGP-8840 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AW 64 Location EQUIP
6 P&ID No. 7650-8110-25-588-2015 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting Top Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm 3" Sch STD N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Waste Water 93 NACE Requirements N/A
35 Upper Fluid Name Air 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 0 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No Yes 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-38.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-88407B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -88407B

PROCESS NOTES:

1. PED classification: Fluid State: L / Group: 1


2. DCC Collection Pit (ECR-UGP-8840), with 3.5 m of deep. Dimensions to be confirmed.
3. High level switch will activate UC-88001 (Pump shall start).
4. Low level switch will activate UC-89002 (Pump shall stop).
5. Low Level height must be updated once the VENDOR confirms minimum submergence level of the pump and the dimensions of the pit has been
established..
6. Level alarms will be confirmed after finalizing pit design.

INSTRUMENT NOTES:
I-1. Gasket Materials: Synthetic Fibre With Oil Resistant Binder.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-38.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-88407B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -89201A 61 Plant ECR_P
3 Service D8920 Light Oil Lvl 62 Unit 89
4 Equipment ECR-D-8920 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-589-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 150 - 1350 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1200 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hidrocarbon - Water 93 NACE Requirements N/A
35 Upper Fluid Name Flare Gases Wet 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,3 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1100 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1,01 3,5 104
46 Design Temperature Min/Max °C -18,3 210 105
47 Dielectric Constant Upper/Lower 2,274 34,5 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-39.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-89201A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -89201A

PROCESS NOTES:
1. PED classification: Fluid State: G / Group: 1.
2. Steam Out: 3.5 barg @210ºC and FV @125ºC.
3. LT with electrical tracing.
4. Low level switch will activate UC-89007 (Stop Pump).
5. High level switch will activate UC-89002 (Start Pump).
6. Lower Fluid: This instrument can work with a mixture of hydrocarbon / water (Density, 700 /1100 kg/m3), so consider a dielectric constant range
between 1.553 - 34.5 (Hydrocarbon - Water).

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-39.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-89201A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -92166 61 Plant ECR_P
3 Service Sump Level 62 Unit 92
4 Equipment ECR-592-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A0LY 64 Location EQUIP
6 P&ID No. 7650-8110-25-592-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Neut. /Corros./ Disp. /water 90 NACE Requirements N/A
32 Upper Fluid Name Air 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Gas/Vapor 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 25 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 1030 96 Fire Safe Design N/A
38 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-40.1 of 88
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-92166 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -92166

Procces Notes:

1. PED Classification fluid stage/group to be confirmed by chemical vendor.


2.Lower Fluid: This instrument can work with a mixture of Neutralizing /Corrosion/ Dispersant/ water (Density, 1030 /1000 kg/m3).

Instruments Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: STUD: ASTM A320 GR. L7 / NUT: ASTM A194 GR. 7, S3.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-40.2 of 88


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-92166 Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -10351A 61 Plant ECR_P
3 Service E1035 Propane Lvl 62 Unit 10
4 Equipment ECR-E-1035 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1GP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-510-2005 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range -196 - 1500 82
24 CHAMBER : 83
25 Chamber Material ASTM A333 GR. 6 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1696 85
27 Vessel Connection Side/Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Propane Feed 93 NACE Requirements N/A
35 Upper Fluid Name Propane Feed 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 7,3 97 Test Requirements See Notes
39 Temperature °C 20 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 501,5 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 10 104
46 Design Temperature Min/Max °C -49 150 105
47 Dielectric Constant Upper/Lower 1,668 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-41.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-10351A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LZT -10351A

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2 Stud & Nut Materials: ASTM A320 Gr. L7 / ASTM A194 Gr. 7, S3.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-41.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-10351A Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -10351B 61 Plant ECR_P
3 Service E1035 Propane Lvl 62 Unit 10
4 Equipment ECR-E-1035 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1GP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-510-2005 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range -196 - 1500 82
24 CHAMBER : 83
25 Chamber Material ASTM A333 GR. 6 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1696 85
27 Vessel Connection Side/Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Propane Feed 93 NACE Requirements N/A
35 Upper Fluid Name Propane Feed 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 7,3 97 Test Requirements See Notes
39 Temperature °C 20 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 502 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 10 104
46 Design Temperature Min/Max °C -49 150 105
47 Dielectric Constant Upper/Lower 1,668 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-42.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-10351B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LZT -10351B

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2 Stud & Nut Materials: ASTM A320 Gr. L7 / ASTM A194 Gr. 7, S3.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-42.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-10351B Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -10351C 61 Plant ECR_P
3 Service E1035 Propane Lvl 62 Unit 10
4 Equipment ECR-E-1035 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1GP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-510-2005 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range -196 - 1500 82
24 CHAMBER : 83
25 Chamber Material ASTM A333 GR. 6 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1696 85
27 Vessel Connection Side/Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Propane Feed 93 NACE Requirements N/A
35 Upper Fluid Name Propane Feed 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 7,3 97 Test Requirements See Notes
39 Temperature °C 20 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 502 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 10 104
46 Design Temperature Min/Max °C -49 150 105
47 Dielectric Constant Upper/Lower 1,668 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-43.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-10351C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LZT -10351C

PROCESS NOTES:
1. PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2 Stud & Nut Materials: ASTM A320 Gr. L7 / ASTM A194 Gr. 7, S3.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-43.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-10351C Rev.: EE1
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -10354 61 Plant ECR_P
3 Service E 1035 Propane Lvl 62 Unit 10
4 Equipment ECR-E-1035 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1GP3 64 Location FIELD
6 P&ID No. 7650-8110-25-510-2005 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting
11 Probe Material SS316/316L 70 Power Supply / From Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Side-Side 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction NA
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range - 82
24 CHAMBER : 83
25 Chamber Material LTCS Group 1.3 84
26 Chamber Size / Centre to Centre mm 3" 1500 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 3" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Propane Feed 93 NACE Requirements N/A
35 Upper Fluid Name Propane Feed 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 7,3 97 Test Requirements See Notes
39 Temperature °C 20 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 502 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 10 104
46 Design Temperature Min/Max °C -49 150 105
47 Dielectric Constant Upper/Lower 1,668 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-44.1 of 88
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-10354 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F729CD7E-C7D4-4545-8D96-ACE85184E9A1

Tag Number : ECR-LT -10354

Process notes:
1. . PED classification fluid state/group-G/1
2. Steam out conditions-125 deg C@FV & 210 deg C@7 barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-44.2 of 88


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-10354 Rev.: EE1