SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CONDUCTORS, BARE
1. 1
BARE CONDUCTORS TYPE ACAR/ACSR/ACSR-AW/AAAC Applicable Standards: 10-TMSS-01
1. 1 Page 1 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. ACAR, ACSR, ACSR/AW AAAC, and Type tests on all PQ Letter
Ltd ACSR/AW Condor type of conductors Based on S&SD letters # 15-01562-1-30504401
Saudi Arabia performed (October dated 18th March 2015 & #
03-09, 2015) at 15-04785-1-30504401 dated 18th November,
Po Box 5989 Jeddah 21432 , Saudi Kinectrics 2015, it is pre-qualified with the following
Arabia Laboratory Toronto conditions:
Canada,
Contact Person - Mr. Loai Taha Al-Bar, Report No. WARRANTY:
Sale Manager K-419714-RC-0001- Ten (10) years extended warranty/guarantee in
Phone - +966-2-591-1115 R01 & . respect of defects due to design, manufacture,
Email ID - Loai.albar@bahra-cable.com K-419714-RC-0002- installation & workmanship from the date of the
R01 Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award
Kinectrics Report # and from the date of first delivery in case of
K-419605-RC-0001- direct material supply order .This was confirmed
R00 & in writing by the manufacturer through their letter
K-419605-RC-0002- # (BCC/SEC/LAB/GSM/MZ) dt: December 9, 2015.
R00
Previously Bahra Cable Co.
Kinectrics Report #
K-419714-RC-0001-
R01 &
K-419714-RC-0002-
R01
(ACSR/AW Condor)
Type test performed
at Bahra Cables
Laboratory (October
16-18, 2018)
Report #
AS-181018-01
1. 1 Page 2 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
JEDDAH CABLE CO. ACAR, ACSR, ACSR/AW Drake, Type test performed PQ Letter
Saudi Arabia ACSR/AW Condor (un-greased) and for ACSR/AW Based on S&SD Letter No. 16-09867-30504401
AAAC, Condor dated 7 Dec 2016 , JEDDAH CABLE Co. Jeddah
Plant -jeddah ACSR/AW Condor (greased) (un-greased) at SPIE -K.S.A is Pre-qualified with following condition.
Laboratory SAG
Po Box 31248 , Jeddah 21497 Jeddah , GmbH WARRANTY:
Saudi Arabia Report# 2020-093 Ten (10) years extended warranty from the date
dated 11- December of PAC of the first turnkey project in case of
jeddah 2020. contract award or date of first delivery in case of
direct material supply order.
Contact Person - Mr. Alaa Dandachi , Type Tests for
Mohammad Said Minkara Conductors type WARRANTY:
Phone - +966-126360770, 0541462998 ACSR, ACSR/AW, Ten (10) years extended warranty in respect of
Email ID - AAAC, ACAR were the defects due to design, manufacturing,
msminkara@cables.energya.com performed in installation and workmanship from the date of the
Contact Person Email ID - KINECTRIC Provisional Acceptance Certificate (PAC) of the
adandachi@cables.energya.com International Inc. first project (in case of contract award) and from
Website - Laboratory– the date of first delivery in case of direct material
http://www.cables.energya.com CANADA , supply order shall be provided as confirmed by
KINECTRICS the manufacturer through their letter
Report# JCC-EP-TT-20-044-05 dated December 23, 2020.
K-419635-RC-0001-
R01,
K-419635-RC-0002-
R01,
K-419635-RC-0003-
R01,
K-419635-RC-0004-
R01,
JCC-EP-PQ-0102-1
4-34.
1. 1 Page 3 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
MIDAL CABLE , ACAR, ACSR, ACSR/AW and AAAC Type test conducted PQ Letter
Saudi Arabia from 25.08.2015 to Based on S&SD letter # 15-09640-030504401
04.09.2015 at dated November 24, 2015, it is pre-qualified with
Plant -Al Khobar different the following conditions:
laboratories in
P.O. Box 2312 Al Khobar 31952 Saudi Germany Viz SAG, WARRANTY:
Arabia ISP Institues, State Ten (10) years extended warranty from the date
Material testing of PAC of the first turnkey project in case of
Contact Person - Mr.Ammar Al Khuzaei institute ,FGH etc. contract award or date of first delivery in case of
General Manager Marketing & Sales , (Test Report # direct material supply order as
Mr. Mahadi Hussain 2015-049A, confirmed through Letter # Nil dated 19.10.2014.
Phone - +966-13-8988989 2015-049C &
+966-509994288 2015-049D)
Email ID - midalksa@midalcable.com
Hussain@midalcable.com Type test performed
Website - http://www.midalcale.com for ACSR/AW
Condor
(Greased &
un-greased)
ACSR Drake
Un-greased, ACAR
548
(Greased &
un-greased),
AAAC 500
(Greased &
un-greased),
ACSR Condor and
Conductor Grease
at SPIE Laboratory
SAG GmbH
Report#
2020-090 A dated
25.11.2020
2020-090 B dated
02.12.2020
2020-090 G dated
02.02.2021
2020-090 I dated
02.02.2021
2020-090 H dated
1. 1 Page 4 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
02.02.2021
2020-090 K dated
08.02.2021
2020-090 J dated
08.02.2021
2020-090 L dated
02.03.2021
2020-090 M dated
16.03.2021
MIDAL CABLE LTD. ACAR, ACSR, ACSR/AW and AAAC Tests performed at:
BAHRAIN Manufacturer’s Lab.
(2014/2013/2010)
Plant -Bahrain Report #:
AAAC/P-1634-C/14/
Midal Cable Ltd. Bahrain Po Box 5939 01
Manama, Bahrain, Bldg. 744 Road 5128 AAAC/P-1196-C/13/
Block 951 Askar Road Bahrain. 08
Manama , Bahrain ACSR/P-890-C/10/0
4
Contact Person - Mr. Ammar Al Khuzaei ACSR/P-1087-C/11/2
Phone - +973-17832832 7
Email ID - ammar@midalcable.com ACSR/AW/P-696C/0
Website - http://www.midalcable.com/ 8/29
ACSR/AW/P-814C-A
/09/03
ACAR/P-1000-C/11/
23
STERLITE ACAR, ACSR, ACSR/AW and AAAC Tests performed at: PQ Letter
INDIA Based on TS&SD Letter #
FGH, Germany 10-F001691/01-03032301 dated 19/06/2010, it is
S. No. 99/P, Madhuban Dam Road, (Dec., 2009) pre-qualified with the following condition:
Rakholi Silvassa 396230 - India
Report # H1005, WARRANTY:
Contact Person - Mr. Vivek Ananad H10006, H10007 Ten (10) years extended warranty/guarantee in
Phone - +91-97-6555-3878 and H10008 respect of defects due to design, manufacture,
Email ID - vivek.anand@sterlite.com installation & workmanship from the date of
Website - Provisional Acceptance Certificate (PAC) of the
http://www.sterlitetechnologies.com turnkey project in case of contract award or date
of delivery in case of direct material supply order.
1. 1 Page 5 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
ALFANAR ELECTRICAL SYSTEMS ACAR, ACSR, ACSR/AW and AAAC Type Tests PQ Letter
Saudi Arabia performed for ACSR Based on S&SD letter# 13-02020-01-30504401
Conductor dated July 30, 2013, it is pre-qualified with the
Plant -3Rd Industrial Area, Al Kharaj at:Kinectrics - following: conditions.
Road, Riyadh Saudi Arabia Canada dated 11th
Feb 2013, Report #
Po Box 301 , Riyadh 11411 , North Righ K419415-RC-0001-R CONDITION:
Road Between Exit 5 & 6 Riyadh , 01 The first batch of AAAC, ACSR/AW & ACAR type
Saudi Arabia conductors shall be type tested at an
independent testing laboratory in the presence of
Riyadh (03) SEC/National Grid SA repreentatives and one
approved third party inspector and all cost
Contact Person - Mr. Ali AlShahrany, pertaining to tests shall be borne by the
Mr. mohamed fathy, Mr. Khaled manufacturer.
Shakour
Phone - 920006111 WARRANTY:
Contact Person Email ID - Ten (10) years extended warranty/guarantee in
Ali.AlShahrany@alfanar.com respect of defects due to design, manufacture,
mohamed.fathy@alfanar.com installation & workmanship from the date of
Khaled.Shakour@alfanar.com Provisional Acceptance Certificate (PAC) of the
Website - www.alfanar.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmd by the manufacturer
through their letter #C-PRQ-2013-02 dated June
17, 2013.
Website - http://www.southwire.com/
Website -
http://www.alcoa.com/usa/en/home.as
p
1. 1 Page 6 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
APAR INDUSTRIES LTD. Imdad Support & ACAR, ACSR, ACSR/AW and AAAC Tests Performed for PQ Letter
INDIA technical AAAC Conductor Based on TS&SD Letter # 10-01566-2-03032300
PO Box 56451 Riyadh (Stress Strain, dated 14/06/2010, it is pre-qualified with the
Plant -Nalagarh Plant, Silvassa Plant 11554 Breaking Strength, following conditions:
Phone - 011-4657556 x UTS and
Nalagarh Plant: 222,311 Longitudinal CONDITION:
Khasra No. 467, Hadbast No. 101, Email – Smoothness) at The first batch of ACSR, ACSR/AW & ACAR type
Muuza Beer Plassi Tec. Nalagarh P.O Imd1adtech@gmail.com VEIKI-VNL, conductors shall be type tested at an
Manjhauli (Jagatkhana) District Solan Budapest – Hungary independent testing laboratory in the presence of
(H.P) 174 101 India in Jan., 2014) (03) SEC/National Grid SA repreentatives and one
Tel: 0091-01795-200384 Report # 7765/VNL approved third party inspector and all cost
E-mail: agv@apar.com pertaining to tests shall be borne by the
manufacturer, as confirmed by the manufacturer
through letter # AIL/BRD/PQ/SEC/19, dt: 22nd
SILVASSA Plant: May, 2010.
Survey No. 148/1 Kudacha, Silvassa,
Rakholi Road, Silvassa (U.T.OFD & NH) WARRANTY:
-396230 INDIA Ten (10) years warranty from the date of PAC of
Tel: 0091-260-2630193-194 the turnkey project in case of contract award or
Fax, 0091-260-2630916 date of delivery in case of direct material supply
E-mail: ashwin@apar.com order. This has been confirmed in writing by the
manufacturer; through letter # AIL/BRD/
SEC/PQ/19 dated 22nd May 2010.
1. 1 Page 7 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
1. 1 Page 8 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
1. 1 Page 9 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Total = 13
CONDUCTORS, BARE
1. 2
GUY WIRE STRAND, GALVANIZED (GROUNDING) Applicable Standards: 10-TMSS-02
SOUTHWIRE
United States
Website - http://www.southwire.com/
TREFILEUROPE
FRANCE
Website -
http://www.mittalsteel.com/Facilities/Eu
rope/Mittal+Steel+Gandrange/Trefileuro
pe/
JOSLYN
United States
Website -
http://www.joslynhivoltage.com/
Total = 4
CONDUCTORS, BARE
1. 3
OVERHEAD GROUND WIRE (OGW) Applicable Standards: 10-TMSS-03
1. 3 Page 10 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Plant -Bahrain
SOUTHWIRE
United States
Website - http://www.southwire.com/
TREFILEUROPE
FRANCE
Website -
http://www.mittalsteel.com/Facilities/Eu
rope/Mittal+Steel+Gandrange/Trefileuro
pe/
ALCOA
United States
Website -
http://www.alcoa.com/usa/en/home.as
p
1. 3 Page 11 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
ECN CG SA
SPAIN
1. 3 Page 12 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
RIYADH CABLES
Saudi Arabia
Plant -Riyadh
1. 3 Page 13 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SAUDI CABLE
Saudi Arabia
Jeddah
Total = 9
CONDUCTORS, BARE
1. 4
OPTICAL FIBER GROUND WIRE (OPGW) Applicable Standards: 10-TMSS-04
Website - http://www.afltele.com/
1. 4 Page 14 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
AFL TELECOMMUNICATIONS GMBH ASLH-D(S) BB Type Tests Previously Draka Comteq Germany GmbH & KG.
GERMANY 96 SMF AL4/A20SA Performed at:
161/21-20,0 Intertek (Sep, 2016) WARRANTY:
Monchengladbach , Germany Report # TB 3246/16 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
ASLH-D(S)bb installation & workmanship from the date of
48 SMF AL4/A20SA Provisional Acceptance Certificate (PAC) of the
163/20-20,0 Type Tests first turnkey project in case of contract award or
(Equivalent to Wolf Performed at: date of first delivery in case of direct material
with 48 Fiber). Intertek (May, 2017) supply order.
Report # TB 3450/17
ASLH-D(S)BB, 96 SMF/NZDSF
AL4/A20SA 65/39-14,6
ASLH-D(S)BB, 96 SMF/NZDSF
AL4/A20SA 78/76-24,0 Type Tests
Performed at:
ASLH-D(S)B, 36 SMF A20SA 37-2,9 Intertek (Oct, 2015)
(ARAMCO Project) Report # TB 3134/15
Type Tests
Performed at:
Intertek (Oct, 2015)
Report # TB 3135/15
Type Tests
Performed at:
Intertek (May, 2011)
Report # TB 2118/11
1. 4 Page 15 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
JIANGSU ZHONGTIAN TECHNOLOGY RADYA International OPGW, 70kN 13.3mm, 48 Fibers Tests performed at: PQ Letter
CO.LTD (ZTT) PO Box: 61891 Riyadh Kinectrics Canada Based on TS&SD Letter # 10-01654-03032301
CHINA 14211 K.S.A (July, 2011) Report # dated June 05, 2010 and S&SD Letter
Tel: +966-11-4966667 K-419311-RC0001-R 12-05204-1-30504401 dated February 04, 2013,
Chinanantong, China Email: 00 it is prequalified with the following condition:
afzal.mohammad@kfbgr
oup.com.sa WARRANTY:
Tests performed at: Ten (10) years extended warranty/guarantee in
OPGW, 120kN, 17.3mm, 48 Fibers Kinectrics Canada respect of defects due to design, manufacture,
(July, 2011) Report # installation & workmanship from the date of
K-419311-RC0002-R Provisional Acceptance Certificate (PAC) of the
00 first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Tests performed at:
Kinectrics Canada
Report #
OPGW, 15.3mm (70kN) & 18.4mm K-419653-RC-0002-
(120kN), 96 Fibers R00 (June 11,2015)
& Report #
K-419653-RC-0003-
OPGW, 18.5mm (77kN) 48 Fibers R00 (June 11,2015).
(OPGW -48B1-185 [77.7 ; 253.9])
Tests performed at:
Kinectrics Canada
Report #
K-419653-RC-0001-
R00 (May 04,2015).
1. 4 Page 16 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.phillipsfitel.com
1. 4 Page 17 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
PRYSMIAN TELECOM Zamil Group Holding co, 6715 120 kN/24 kA 48 core, Tests performed at: PREVIOUSLY "PIRELLI"
SPAIN Commercial Div 6716 70 kN/13 kA 48 core Kinectrics Canada
www.zamilcd.com.sa Report # PQ Letter:
Plant -Vilanova I La Geltru/Spain Phone - K-419533-RC-0002- Based on S&SD Letter # 22-00491-30504401
966-0-504-320-776 8609 120 kN/24 kA 96 core, R01 (May, 2014) dated April 14, 2022 Prysmian is pre-qualified for
Ctra. C-15,Km, 2-P.I. Masia D’En Notari Email - 8610 70 kN/13 kA 96 core Report # OPTICAL FIBER GROUND WIRE (OPGW) as
08800 Vilanova I La Geltru ( Spain) khaleds@zamilcd.com.s K-419530-RC-0001- conforming to National Grid SA specification
a 8146 77.8kN/18 kA 48 core (94P64Dz) R00 (Jan, 2013) 10-TMSS-04, with the following conditions:
Contact Person - Mr. Toni Nieto
Phone - +34608749306 WARRANTY:
Email ID - 9217 73.3 kN/29.1 kA, 19.0 mm, 96 Type Tests Twenty (20) years extended warranty/guarantee
Antonio.nieto@prysmiangroup.com core (90Q74z) Performed at: against corrosion protection of OPGW in respect
Website - Kinectrics Canada of defects due to design, manufacture,
http://www.prysmiangroup.com 1. OPGW 120kN (96 fibers), Type: Report # installation and workmanship from the date of
80N84DzG (11541), 27.5KA, 18mm K-313065-RC-0001- Provisional Acceptance Certificate (PAC) of the
(Greased) R00 (Jan, 2019) first turnkey project in case of contract award or
2. OPGW 70kN (96 fibers), Type: date of first delivery in case of direct material
51H54DzG (11542), 19.4KA, 15.1mm 1. Shanghai supply order, as confirmed by the manufacturer
(Greased) National Center, vide letter # Letter #SS 15022021-01 dated
3. Anti-Corrosion Grease (for China Type Test 15/02/2020.
OPGW) Report No. CT21-
4. OPGW 120kN (96 fibers), Type: 03000 dated
67L85z(10755), 24KA, 16.7mm 15.10.2021 PQ Letter:
5. OPGW 70kN (96 fibers), Type: 2. Shanghai Based on S&SD letter #22-00491-30504401
32C51z(10756), 13KA, 13.2mm National Center, dated April 14, 2022 & letter #
China Type Test 22-01014-30504401 dated August 10, 2022 the
Report No. CT21- manufacturer is prequalified for OPTICAL FIBER
02626 dated GROUND WIRE (OPGW), as conforming to
02.09.2021 National Grid SA specification # 10-TMSS-04,
3. Shanghai with the following conditions:
National Center,
China Type Test WARRANTY:
Report No. CT21- Ten (10) years extended warranty from the date
02627 dated of PAC of the first turnkey project (in case of
03.09.2021 contract award) or date of first delivery (in case
4. Report # of direct material supply order), as confirmed,
PRYSMIAN-OPGW through their Letter #OPGW-KSA-0722 dated
67L85z(10755) July 19, 2022, shall be applicable for the
dated 29.11.2021, equipment to be supplied to SEC/National Grid SA.
TICW Shanghai
Report#
CT21-04430-1 dated
1. 4 Page 18 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
DRAKA NK
FINLAND
Website - http://www.draka.com/
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
PIRELLI
ITALY
BRUGG TELECOM AG
SWITZERLAND
Website - http://www.brugg.com/
1. 4 Page 19 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CORNING CABLES
United Kingdom
Website -
http://www.corningcablesystems.com/
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution OPGW-120kN, 36 Fibers, 17.9mm Tests performed at: PQ Letter
KOREA, Republic of Co., Ltd. Branch Al-Tube type Kinectrics Canada, Based on TS&SD letter# 09-F00730/03-03032301
P. O. Box 300201, KERI & Taihan (2011) dated 24th August 2009, it is prequalified with the
Plant -Dangjin Factory Riyadh 11372, Office No. (New) following condition:
18, Commercial Complex 96C 14.9mm (New)
317, Simin Daero, Dongan-gu Building, King Abdulaziz 96C 18.5mm Taihan Electric Wire WARRANTY:
Rd. Exit 5, Kingdom of Co. Ltd - Korea has Ten (10) years extended warranty/guarantee in
Anyang-si Saudi Arabia successfully respect of defects due to design, manufacture,
+966 11 410 1773 completed the type installation & workmanship from the date of
Contact Person - Jang Hee Lee hslee0822@taihan.com tests of Fiber Optical Provisional Acceptance Certificate (PAC) of the
Phone - +82 2 316 9190 Ground Wire first turnkey project in case of contract award or
Email ID - janghee@taihan.com (OPGW) in date of first delivery in case of direct material
Contact Person Email ID - independent supply order , as confirmed by the manufacturer
janghee@taihan.com laboratory through their letter no.nil, dt: 30/03/2008.
Website - www.taihan.com (KINECTRICS,
Canada) report # (New)
K-419657-RC-0001- PQ letter:
R00 during March Based on S&SD letter # 17-08663-30504401
16, 2015 & dated December 18, 2017, Taihan Electric Wire
RC-0002-R00 during Co. Ltd - Korea is pre-qualified for Fiber Optical
March 17,2015 in Ground Wire (OPGW) as conforming to latest
the presence of National Grid SA specification # 10-TMSS-04
SEC/National Grid
SA Engineers. WARRANTY:
• Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # TENA171206-01, dated December
06, 2017.
Total = 13
1. 4 Page 20 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CONDUCTORS, BARE
1. 5
BARE, COPPER-CLAD STEEL GROUNDING CONDUCTOR AND GROUND ROD Applicable Standards: 10-TMSS-05
2. Plant Address:
NO:8, LANE 24, QIANSHI STREET,
LIUSHI TOWN, YUEGING CITY,
WENZHOU CITY
ZHEJIANG PROVINCE, CHINA.
3. Branch Address:
LANE 658, GAUNGFULIN ROAD,
SONGJIANG DISTRICT, SHANGHAI
,CHINA .
1. 5 Page 21 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website -
http://www.jiwoong.co.kr/main
eng.html
Copperweld Bimettalics LLC Litwin Saudi Arabia Previously LTV Copperweld, name has been
United States Company Ltd. changed based on Copperweld Bimettalics letter
P.O. Box 3739, # Nil dated January 03,2018.
Plant -Fayetteville, Tennessee Al-Khobar 31952,
Kingdom of Saudi Arabia.
254 Cotton Mill Road
Fayetteville, Tennessee 37334 Jamal Mohammad Abu
U.S.A. Ajinah
Manager Industrial
Tennessee Trading
+966 13 893 8557; +966
Contact Person - Mr. Dustin Smith 504 169 720
Phone - +1 931-433-0400 / +1 jamal@litwinksa.com
615-377-4200
Website -
http://www.bimettalics-copperweld.co
m
COMSCOPE BIMETALS
United States
Website - http://www.fmsudafix.com/
1. 5 Page 22 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
A. N. Wallis & Co. Ltd. 16mm dia, 3000mm length, Drawing # Type tests PQ Letter:
United Kingdom ERB130 conducted at Based on S&SD letter # 16-10652-030504401
ELEMKO SA THIVA dated December 25,2016, A. N. Wallis & Co. Ltd.
Plant -United Kingdom GREECE, Report # – UK is pre-qualified for Grounding Rod &
32050 dated accessories as conforming to National Grid SA
Greasley Street, Bulwell, Nottingham, 20/12/2021 specification # 10-TMSS-05, with the following
United Kingdom conditions:
Nottingham WARRANTY:
Ten (10) years Extended Warranty as confirmed
Contact Person - Mark Rimmington, through Letter No. ANW/NG SA/ SEC / EW/ L01 /
Director 2016 dated 27/10/2016 shall be applicable for all
Phone - +44(0)1159271721 supplies to the Company by A. N. Wallis & Co.
Email ID - info@an-wallis.com Ltd. – UK
Website - www.an-wallis.com
Dammam WARRANTY
Ten (10) years extended warranty/guaranty from
Phone - +966 11 484 5639 the date of (PAC) of the Turnkey project (In case
Email ID - mohammed.ziad@sa.abb.com of contract award) and from the date of delivery
Contact Person Email ID - Mr. for the direct material supply order. The
Mohammad Ziad , Project Manager guarantee/warranty shall be applicable from first
Website - www.ABB.com project and shall cover all the cost of materials
and labor as per warranty/guarantee of materials
and workmanship and subsequently reduced
yearly in case of future project award. This was
confirmed in writing by ABB Furse through their
letter # nil dated # 20.07.2018.
1. 5 Page 23 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SADAF Electric Industries Co. (SEICO Previously " Legrand Saudi electric Co.", the
Ltd). name has been changed to " SADAF Electric
Saudi Arabia Industries Co. (SEICO Ltd).
Plant -Jeddah
Note:
Jeddah,KSA Previously " Saudi Electric Industries Company
Ltd. (SEICO) ", the name has been changed to "
Jeddah Legrand Saudi Electric Industries Company Ltd".
based on their letter # Nil dated October 30,
Contact Person - Mr. Kurian Mathew - 2017.
CEO, Robben Zacharia - Sales
Manager
Contact Person Email ID -
kurian.mathew@ayalyami.com -
robben.zacharia@seico-sa.com
Website - www.seico-sa.com
Total = 8
CONDUCTORS, BARE
1. 6
HEAT-RESISTANT ALUMINUM ALLOY BARE CONDUCTORS FOR OVERHEAD LINE Applicable Standards: 10-TMSS-06
1. 6 Page 24 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
1. 6 Page 25 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Sumitomo Electric Industries Middle East Regional GAP Type & INAVR Type Conductors: Test performed at: Based on S&SD letter#20-02008-30504401 dated
JAPAN Office GTACSR, GZTACSR and Toyoura Works 13 December 2020, the name was changed from
Mr. Amjad Abdelaziz ZTACIR/AS, XTACIR/AS (JECTEC) Nov./Dec. J-Power Systems to Sumitomo Electric Industries
Plant -JAPAN-Hitachi ,General Manager 2014, Oct. 2009,
abdelaziz-amjad@sei.co. Jan. 2013, Mar. PQ Letter
3-13-16 Mita- Minato-Ku, Tokyo jp 2004, & Sep 2007 Based on TS&SD letter# 09-00649-1-03032301
108-0073 , Japan dated 28 March 2009 and S&SD letter no.
Report # 15-00017-1-30504401 dated 8th Feb 2015 it is
Contact Person - Shiro Nomura & Mr. JTR12AY091245, pre-qualified for Heat Resistant Conductors
Amjad Abdelaziz JTR12AY-13092, subject to the following conditions:
Contact Person Email ID - JTR12-AY044167,JT
nomura-shirou@sei.co.jp & R12-AY07980, WARRANTY:
abdelaziz-amjad@sei.co.jp JTR12-AY07092, Ten (10) years extended warranty in respect of
Website - JTR12-AY12107,JTR the defects due to design, manufacturing &
http://www.jpowers.co.jp/english/inde 12-AY09913 & workmanship from the date of the Provisional
x.html JTR12-Ay141633 Acceptance Certificate (PAC) of the first turnkey
project (in case of contract award) and from the
Type Tests date of first delivery in case of direct material
performed from 27th supply order shall be provided as confirmed by
Nov to 5th Dec 2014 the manufacturer through their letters #
at: #JLX80-15-0013 dated 5th Feb 2015 and
Japan Electric Cable JLX80-15-0022 dated March 02nd, 2015.
technology
Center(JECTEC) Lab
Shizuoka, Japan.
Report#
IR-2014-5001-40261
-001
Total = 3
CONDUCTOR, INSULATED
2. 1
POWER CABLE, XLPE, CU OR AL, 1-CORE, 69 kV Applicable Standards: 11-TMSS-01
2. 1 Page 26 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SAUDI CABLE
Saudi Arabia
Jeddah
2. 1 Page 27 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.alcatel.fr/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
2. 1 Page 28 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.ffcpg.com.my
Email ID - lang=en
Website -
http://www.mkm-?mediline.de/index.ph
p/edv-und-software-?entwicklung/mkm
-computer-network-?ungarn?lang=en?
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
Website - http://www.draka.com/
Website - http://
http://www.suedkabel.de/index e.htm
2. 1 Page 29 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
JEDDAH CABLE CO. XLPE Cable Type tested in 2010 Based on S&SD letter# 16-06823-30504401
Saudi Arabia 1x1200mm² Report # TDT dated August 14, 2016, the manufacturer is
1002-10 prequalified for XLPE Insulated Power Cable as
Plant -jeddah , 69 kV confirming to SEC specification # 11-TMSS-01,
Rev.0, with the following condition:
Po Box 31248 , Jeddah 21497 Jeddah ,
Saudi Arabia • Ten (10) years extended warranty for XLPE
Power Cable from the date of PAC of the turnkey
jeddah project in case of contract award and date of
delivery in case of direct material supply order,
Contact Person - Mr. Alaa Dandachi , as confirmed by the manufacturer through letter
Mohammad Said Minkara #NIL dated August 14, 2016.
Phone - +966-126360770, 0541462998
Email ID -
msminkara@cables.energya.com
Contact Person Email ID -
adandachi@cables.energya.com
Website -
http://www.cables.energya.com
Total = 13
CONDUCTOR, INSULATED
2. 2
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE, 110 TO 132 kV Applicable Standards: 11-TMSS-02
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed at: TAIHAN ELECTRIC WIRE COMPANY Manufacture
KOREA, Republic of Co., Ltd. Branch KEMA shall perform a system type test for HV optimized
P. O. Box 300201, Netherlands (Mar design as per National Grid SA 11-TMSS-02,
Plant -Dangjin Factory Riyadh 11372, Office No. 1995, Dec Rev.02 Cable
18, Commercial Complex 2009 & June 2013)
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
2. 2 Page 30 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 2 Page 31 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 2 Page 32 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 2 Page 33 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
RIYADH CABLES 110 TO 132kV, Tests performed at: Based on S&SD letter # 16-04560-30504401
Saudi Arabia 1x2500mm2 KEMA dated June 12, 2016, the manufacturer is
Netherlands (Jan. prequalified for XLPE cable 132KV,as
Plant -Riyadh Optimized Design HV Cable 132KV, 2014) conforming to National Grid SA specification #
1X1200mm². Report # TIC 11-TMSS-02, Rev.01.
P.O. Box 26862- Riyadh, 11496 Riyadh 1489-13
, Saudi Arabia PQ Letter
2nd Industrial City, Al Kharj Road, street Type /Special tests Based on S&SD letter# 19-01513-01-30504401
No. 175, 3rd Lane Zone D. Riyadh, were successfully dated June 10, 2019, the manufacturer is
Kingdom of Saudi Arabia conducted along prequalified for Optimized Design HV Cable
with following cable 132KV, 1X1200mm², CU/XLPE as confirming to
Contact Person - Mr. Dr. Abdulmohsen accessories from National Grid SA specification # 11-TMSS-02,
Aliheraish – Vice Executive Director; Brugg Cables at with the following conditions:
Mr. Mohammad Al-Shmoury, KINECTRIC –
Phone - +966 11 2650850 Ext:238 ; Canada. Report No: Riyadh cable shall perform a system type test for
+966 11 2651415 K-423363 HV optimized design of 1x2500mm2, 132kV
Email ID - heraish@riyadh-cables.com; RC-0000-R0 & SGS Cable.
Technical@riyadh-cables.com; Inspection report #
rcgc@riyadh-cables.com 01.14189 Rev.0 & WARRANTY
Website - KEMA Tests on Joint Ten (10) years extended warranty from the date
http://www.riyadh-cables.com/ Outer Protection – of PAC of the first turnkey project (in case of
Extract of Report TIC contract award) or date of first delivery (in case
1012-14: of direct material supply order), as confirmed,
I. Porcelain Insulated through their Letter No. TNN-04/0666 dated
Outdoor Sealing End 22/04/2018 shall be applicable for the equipment
from Brugg Cables - to be supplied to SEC/National Grid SA.
Type # TE 1.170-01
II. SF6 Gas Insulated
Sealing End from
Brugg Cables - Type
#
TF 1.170-12
III. Insulating Joint
from Brugg Cables -
Type # MPAP
1.145-33
For Optimized
Design HV Cable
132KV, 1X1200mm²:
DNV.GL/KEMA
Laboratories
2. 2 Page 34 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
LS PREVIOUSLY LG;
SOUTH KOREA
LS Manufacture shall perform a system type test
Website - http://www.lscable.com/ for HV optimized design as per National Grid SA
11-TMSS-02, Rev.02 Cable
2. 2 Page 35 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
DUBAI CABLE CO. HV Optimized Design Cable 132kV, Type test conducted PQ Letter
United Arab Emirates 1X1200mm² CU/XLPE Power Cable in KEMA DNV-GL – Based on S&SD Letter # 22-01319-30504401
Netherland, Lab dated January 02, 2022,Manufacturer is
P.O.Box 683, Dubai - U.A.E Report No.1600-20 pre-qualified for POWER CABLE, XLPE
dated 05/05/2021 INSULATED, COPPER CONDUCTOR, SINGLE
Contact Person - Mr. Ahmed Abou SGS Report – Type CORE, 110 TO 132 kV as conforming to National
Elenien Test Report no. Grid SA Specification # 11-TMSS-02, Rev.02 with
Phone - (+9714) 815 8600 01.15032 Rev.5 the following conditions:
Email ID - ducabhv@ducab.com dated 03/06/2021
Contact Person Email ID - WARRANTY
ahmed.abouelenien@ducab.com, Short Circuit Test Ten (15) years extended warranty from the date
Alpar.Oztoprak@ducab.com, conducted in KEMA of PAC of the first turnkey project (in case of
Firas.Chadli@ducab.com DNV-GL – contract award) or date of first delivery (in case
Website - www.ducab.com Netherland, Lab of direct material supply order), as confirmed,
Report No.1473-20 through their Letter No. SE211109FC-2 dated
dated 05/05/2021 November 09, 2021 shall be applicable for the
SGS Report – Short equipment to be supplied to SEC/National Grid SA.
Circuit Test Report
no. 01.15032.13
Rev.02
Pre-Qualification
Test conducted in
KEMA DNV-GL –
Netherland, Lab
Report No. 1601-20
dated 06/05/2021
SGS Report –
Pre-Qualification
Test Report no.
01.15047 Rev.02
dated 03/06/2021.
2. 2 Page 36 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 2 Page 37 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
DEMIRER KABLO SSC Jeddah Tests performed at: DEMIRER KABLO Manufacture shall perform a
TURKEY PO Box 4403 , Jeddah XLPE 1x2500 mm2, Kinectrics Canada system type test for HV optimized design as per
Saudi Arabia 132 kV (Sep. 2013 to Sep. National Grid SA 11-TMSS-02, Rev.02 Cable
Demirer Kablo, Tesisleri San. Ve Tic 2014)
A.S. 4 Eylul Mahallesi Ismet Inonu Report # 423151
Caddesi No. 279 Bozuyuk/ Bilecik-
Turkey
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
BRUGG 110 kV to 132 kV. Tests performed at: NAM. GIS termination, Transformer Termination,
SWITZERLAND KEMA Outdoor termination, Cross bonding & Straight
Netherlands Through Joints - XLPE Cables 16 Models of XLPE
5201 Brugg Switzerland,28 Ch5201 Report # TDT cable
Brugg Switzerland, 3148-10 (2011)
70851907-TDT-09-6 BRUGG CABLE Manufacture shall perform a
Contact Person - Mr. Amr Soudi; 9942A system type test for HV optimized design as per
Regional Sales Manager (2009) & TIC National Grid SA 11-TMSS-02, Rev.02 Cable
Contact Person Email ID - 1012-14(2014
amr.soudi@bruggcables.com,
rolf.aregger@bruggcables.com
Website - www.bruggcables.com
2. 2 Page 38 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
ALFANAR ELECTRICAL SYSTEMS HV Optimized Design Cable 132kV, *Type test PQ Letter
Saudi Arabia 1X1200mm² CU/XLPE performed in Based on S&SD letter # 18-4748-01-30504401
DNV-GL (KEMA) – dated December 31, 2018, the manufacturer is
Plant -3Rd Industrial Area, Al Kharaj Netherland testing prequalified for Optimized Design HV Cable
Road, Riyadh Saudi Arabia laboratory Report # 132KV, 1X1200mm² CU/XLPE as conforming to
1567-18, 1676-17. National Grid SA specification # 11-TMSS-02,
Po Box 301 , Riyadh 11411 , North Righ Rev.02, with the following condition:
Road Between Exit 5 & 6 Riyadh , • Al Fanar Cables shall preform a system type
Saudi Arabia test for HV Optimized Design of 1x2500 mm²,
132kV Cable.
Riyadh
WARRANTY
Contact Person - Mr. Ali AlShahrany, Ten (10) years extended warranty in respect of
Mr. mohamed fathy, Mr. Khaled the defects due to design, manufacturing,
Shakour installation and workmanship from the date of the
Phone - 920006111 Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - 132KV HV Cable *Independent testing first project (in case of contract award) and from
Ali.AlShahrany@alfanar.com 1x1200mm2 XLPE laboratory the date of first delivery in case of direct material
mohamed.fathy@alfanar.com KEMA/DNV.GL – supply order shall be provided as confirmed by
Khaled.Shakour@alfanar.com Netherland Lab the manufacturer through their letter
Website - www.alfanar.com during 22nd to 27th MPQ102382-ClassI(a)-2018 dated 20/12/2018.
July 2015 , KEMA
report # 1241-15 &
1242-15 dated
16.09.2015 & SGS PQ Letter
report # 01.13864 •Based on S&SD letter# 17-00831-1-30504401
Rev.1 dated dated February 14, 2017, the manufacturer is
04.08.2015. prequalified for 1x1200MM2 XLPE High Voltage
Cables for 132KV as confirming to SEC
specification # 11-TMSS-02, Rev.1, with the
following condition:
WARRANTY
•Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter
MPQ102382-ClassI(a)-2016 dated 07/02/2017.
2. 2 Page 39 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
JEDDAH CABLE CO. 1x1200mm2 All models type Based on TS&SD Letter #10-02784-01-03032301
Saudi Arabia (110kV & 132kV) tested at: dated October 10,2014 and S&SD Letter
KEMA Netherlands #14-04876-01-30504401 dated july 16 2014. It is
Plant -jeddah 1x2000mm2 (2010, prequalified for 132 kV , 1x2500mm2
(115kV & 132kV) 2012, 2013 & 2014) CU/XLPE/CWS/LAT/HDPE Power Cable as
Po Box 31248 , Jeddah 21497 Jeddah , Report # TIC confirming to N ational Grid Specification #
Saudi Arabia 1x2500mm2 132kV 1065-12, TIC 11-TMSS-02 Rev.1 with the following condition
1002-13, TDT
jeddah 1001-10, TIC Ten ( 10) years extended wararanty for XLPE
1072-12, TIC Power cable from the date of PAC of the turnkey
Contact Person - Mr. Alaa Dandachi , 1013-14 project in case of contract award or date of
Mohammad Said Minkara delivery in case of direct material supply order.
Phone - +966-126360770, 0541462998 This was confirmed in writing by Jeddah cable.
Email ID - Co. through letter #nil dated 26th June 2006.
msminkara@cables.energya.com
Contact Person Email ID -
adandachi@cables.energya.com
Website -
http://www.cables.energya.com
2. 2 Page 40 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. 132KV, 1x1200mm2 Optimized Design Type test & long PQ Letter
Ltd Cu/XLPE Power Cable duration Based on S&SD letter# 19-01209-01-30504401
Saudi Arabia prequalification test dated April 29, 2019, the manufacturer is
1x2500mm2 (132kV) HV Optimized performed in prequalified for 132KV, 1x1200mm2 Optimized
Po Box 5989 Jeddah 21432 , Saudi Design DNV.GL/KEMA Design Cu/XLPE Power Cable as confirming to
Arabia Testing Laboratories National Grid SA specification # 11-TMSS-02,
Arnhem Netherland. with the following conditions:
Contact Person - Mr. Loai Taha Al-Bar, Type Test Date:-
Sale Manager 28.09.2018 to Bahra Advanced Cable Manufacture Co. Ltd –
Phone - +966-2-591-1115 19.03.2019 Jeddah, KSA shall perform a system type test for
Email ID - Loai.albar@bahra-cable.com Long Duration HV optimized design of 1x2500mm2, 132kV Cable
Prequalification Test
Date:- 03.05.2018 – WARRANTY
30.01.2019 Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
DNV.GL/KEMA contract award) or date of first delivery (in case
Laboratories of direct material supply order), as confirmed,
Arnhem Netherland through their Letter No. 1030/BH/2017 dated
Type Test Report, 22/03/2017 shall be applicable for the equipment
Short Circuit Test to be supplied to SEC/National Grid SA.
Report & Long
Duration
Prequalification Test PQ Letter
Report # 1819-18 Based on S&SD letter #22-01130-30504401
dated April 2, 2019, dated August 31, 2022, the manufacturer is
2333-18 dated prequalified for POWER CABLE, XLPE
February 02, 2019 & INSULATED, COPPER CONDUCTOR, SINGLE
1815-18 dated CORE, 110 TO 132 kV type: 76/132 (145) KV
March 22, 2019 1x2500mm² CU/XLPE/LC/HDPE HV Power Cable
respectively. (Optimized Design) as confirming to National Grid
SA specification # 11-TMSS-02, with the
Type test conducted following conditions:
in KEMA
Lab-Netherland from WARRANTY
31st May to 10th Ten (10) years extended warranty from the date
June 2022 of PAC of the first turnkey project (in case of
Type Test Reports # contract award) or date of first delivery (in case
2161-22, 1123-22 & of direct material supply order), as confirmed,
1122-22 through their Letter #Nil dated August 29, 2022,
SGS Report # shall be applicable for the equipment to be
01.15208 Rev.02 supplied to SEC/National Grid SA.
2. 2 Page 41 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Total = 19
CONDUCTOR, INSULATED
2. 3
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE, 230 kV Applicable Standards: 11-TMSS-02
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed at: WARRANTY:
KOREA, Republic of Co., Ltd. Branch KEMA Ten (10) years extended warranty/guarantee in
P. O. Box 300201, Netherlands respect of defects due to design, manufacture,
Plant -Dangjin Factory Riyadh 11372, Office No. installation & workmanship from the date of
18, Commercial Complex Provisional Acceptance Certificate (PAC) of the
317, Simin Daero, Dongan-gu Building, King Abdulaziz first turnkey project in case of contract award or
Rd. Exit 5, Kingdom of date of first delivery in case of direct material
Anyang-si Saudi Arabia supply order.
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
JEDDAH CABLE CO. 1x2500mm2 CU/XLPE, 230kV Type test performed PQ Letter
Saudi Arabia in DNV-GL (KEMA) – Based on S&SD letter # 18-03331-02-30504401
Netherland testing dated September 18, 2018 Jeddah Cable Co ,
Plant -RABIGH laboratory, report # Rabigh, Saudi Arabia is pre-qualified for 230kV,
1377-16 1x2500mm2 CU/XLPE Cables as conforming to
Exit 294, Rabigh Industrial area, Rabibh Prequalification Test National Grid SA specification # 11-TMSS-02
K.S.A performed in
DNV-GL (KEMA) – Warranty
RABIGH Netherland testing Ten (10) years extended warranty/guaranty
laboratory, report # from the date of (PAC) of the Turnkey project (In
Contact Person - Mr. Alaa Dandachi, 1404-18 case of contract award) and from the date of
Mohammad Said delivery for the direct material supply order. The
Phone - 012 636 0770 , 0541462998 guarantee/warranty shall be applicable from first
Contact Person Email ID - project and shall cover all the cost of materials
adandachi@cables.energya.com, and labor as per warranty/guarantee of materials
msminkara@cables.energya.com - and workmanship and subsequently reduced
Website - www.cables.energya.com yearly in case of future project award. This was
confirmed in writing by Jeddah cable. Co. through
their letter # nil dated # nil.
2. 3 Page 42 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
RIYADH CABLES 230KV Cable CU/XLPE, 1X2500sqmm Type test performed PQ Letter
Saudi Arabia in DNV-GL (KEMA) –
Netherland testing Based on S&SD Letter # 22-01397-30504401
Plant -Riyadh laboratory, report # dated 20.10.2022, the manufacturer is
1821-18 & 2123-18, prequalified for 230KV Cable as conforming to
P.O. Box 26862- Riyadh, 11496 Riyadh Prequalification Test National Grid SA specification # 11-TMSS-02,
, Saudi Arabia performed in with the following conditions:
2nd Industrial City, Al Kharj Road, street DNV-GL (KEMA) –
No. 175, 3rd Lane Zone D. Riyadh, Netherland testing Warranty:
Kingdom of Saudi Arabia laboratory, report # Ten (10) years extended warranty from the date
1702-19 for 380 kV, of PAC of the first turnkey project (in case of
Contact Person - Mr. Dr. Abdulmohsen Extended to cover contract award) or date of first delivery (in case
Aliheraish – Vice Executive Director; 230 kV. of direct material supply order). as confirmed,
Mr. Mohammad Al-Shmoury, through their letter No. TMN-10/0665, dated
Phone - +966 11 2650850 Ext:238 ; October 10, 2020, shall be applicable for the
+966 11 2651415 equipment to be supplied to SEC/National Grid SA.
Email ID - heraish@riyadh-cables.com;
Technical@riyadh-cables.com;
rcgc@riyadh-cables.com
Website -
http://www.riyadh-cables.com/
2. 3 Page 43 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
2. 3 Page 44 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
Contact Person - Mr. Amr Soudi; laboratory in presence of representative of 3rd
Regional Sales Manager party inspection agency & three engineers of
Phone - +41 79 9135155 SEC for first contract.
Email ID -
rolf.aregger@bruggcables.com WARRANTY:
Contact Person Email ID - Ten (10) years extended warranty/guarantee in
amr.soudi@bruggcables.com respect of defects due to design, manufacture,
Website - www.bruggcables.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Website - http://
http://www.suedkabel.de/index e.htm
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
Total = 12
2. 3 Page 45 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CONDUCTOR, INSULATED
2. 4
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE 380 kV Applicable Standards: 11-TMSS-02
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 1x2500mm2 Tests performed at: PQ Letter
KOREA, Republic of Co., Ltd. Branch CWS Type, KEMA Based on S&SD letter # 14-08139-01-30504401
P. O. Box 300201, 380 kV with the following drawing Netherlands (Jan. dated: January 07, 2015, the manufacturer is
Plant -Dangjin Factory Riyadh 11372, Office No. numbers: 2014 to prequalified to supply 380kV 1x2500mm2 CWS
18, Commercial Complex May, 2014) Type power cables:
317, Simin Daero, Dongan-gu Building, King Abdulaziz - Power cable: Report # TIC
Rd. Exit 5, Kingdom of TXCCD-3802500-130501. 3094-14 WARRANTY:
Anyang-si Saudi Arabia Ten (10) years extended warranty in respect of
+966 11 410 1773 the defects due to design, manufacturing,
Contact Person - Jang Hee Lee hslee0822@taihan.com installation and workmanship from the date of the
Phone - +82 2 316 9190 Provisional Acceptance Certificate (PAC) of the
Email ID - janghee@taihan.com first turnkey project (in case of contract award)
Contact Person Email ID - or from the date of first delivery in case of direct
janghee@taihan.com material supply order shall be provided as
Website - www.taihan.com confirmed by the manufacturer through their
letter # Nil dated September 02, 2014.
2. 4 Page 46 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 4 Page 47 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
ILJIN ELECTRIC CO. LTD. Dopa Co. for Trading and 380kV XLPE Cable 1x2500mm² Based on S&SD letter# 16-2299-02-30504401
SOUTH KOREA industry CU/XLPE/LEAD/HDPE dated May 02, 2016, it is prequalified for380kV
Al Nuzha District Riyadh, XLPE Cable 1x2500mm² CU/XLPE/LEAD/HDPE as
Plant -South KOREA Saudi Arabia P.O. Box conforming to National Grid SA Material
87017 Code No. 11462 Specification 11-TMSS-02, Rev 01 with the
905-64, Mannyeon-ro, Hwaseong-si, Mr. Abdullah Alabdullah following conditions:
Gyeonggi-do Email /
alabdullah@dopacompan • Ten (10) years extended warranty from the
Contact Person - Mr. Tony Lim, Mr. y.com date of PAC of the turnkey project in case of
Daniel Park TEL / (+966) 11 2694609 contract award and date of delivery in case of
Phone - +82-2-707-9253 , Mobile / (+966) direct material supply order, as confirmed by the
Email ID - yeongchang.lim@iljin.co.kr; 504122831 manufacturer through letter # ILJHC-160412 A
daniel.park@iljin.co.kr dated 12/04/2016.
RIYADH CABLES 1X2500 mm2 CU/XLPE, 380kV Type test performed PQ Letter:
Saudi Arabia in DNV-GL (KEMA) –
Netherland testing Based on S&SD letter# 20-00230-01-30504401
Plant -Riyadh laboratory, report # dated January 30, 2020, the manufacturer is
1821-18 & 2123-18, prequalified for EHV Cable 380kV 1X2500mm2,
P.O. Box 26862- Riyadh, 11496 Riyadh Prequalification Test CU/XLPE, as confirming to National Grid SA
, Saudi Arabia performed in specification # 11-TMSS-02, with the following
2nd Industrial City, Al Kharj Road, street DNV-GL (KEMA) – conditions:
No. 175, 3rd Lane Zone D. Riyadh, Netherland testing
Kingdom of Saudi Arabia laboratory, report # WARRANTY:
1702-19
Contact Person - Mr. Dr. Abdulmohsen Ten (10) years extended warranty from the date
Aliheraish – Vice Executive Director; of PAC of the first turnkey project (in case of
Mr. Mohammad Al-Shmoury, contract award) or date of first delivery (in case
Phone - +966 11 2650850 Ext:238 ; of direct material supply order), as confirmed,
+966 11 2651415 through their Letter No. TNN-02/1001 dated
Email ID - heraish@riyadh-cables.com; January 22, 2020 shall be applicable for the
Technical@riyadh-cables.com; equipment to be supplied to SEC/National Grid SA.
rcgc@riyadh-cables.com
Website -
http://www.riyadh-cables.com/
2. 4 Page 48 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
VISCAS FUJIKURA
JAPAN
Website - http://
http://www.viscas.com/e contact.html
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
2. 4 Page 49 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
5201 Brugg Switzerland,28 Ch5201 laboratory in presence of representative of 3rd
Brugg Switzerland, party inspection agency & three engineers of
SEC for first contract.
Contact Person - Mr. Amr Soudi;
Regional Sales Manager WARRANTY:
Contact Person Email ID - Ten (10) years extended warranty/guarantee in
amr.soudi@bruggcables.com, respect of defects due to design, manufacture,
rolf.aregger@bruggcables.com installation & workmanship from the date of
Website - www.bruggcables.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
2. 4 Page 50 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.suedkabel.de/index e.htm
Total = 13
CONDUCTOR, INSULATED
2. 5
POWER CABLE, LPOF, CU, 1-CORE, CABLE –110 kV TO 132 kV Applicable Standards: 11-TMSS-03
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Rating - 132kV KEMA, Netherlands Including Joints & Terminations
KOREA, Republic of Co., Ltd. Branch July 2000
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
2. 5 Page 51 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.swcc.co.jp/eng/index.htm
Website - http://www.alcatel.fr/
Website - http://
http://www.bruggcables.com/index/ind
ex.cfm?page=home&sprache=de
Website -
http://www.nexans.com/eservice/Navi
gate.nxnavigationRef=
-10&CZ=Corporate
Website - http://
http://www.daetwyler.net/e/index.htm
2. 5 Page 52 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Website - http://www.ffcpg.com.my/
2. 5 Page 53 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Including Joints & Terminations
Plant -Gumi/Korea
Total = 15
CONDUCTOR, INSULATED
2. 6
POWER CABLE, LPOF, CU, 1-CORE, 230 kV Applicable Standards: 11-TMSS-03
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Feb. 2006 Including Joints & Terminations.
KOREA, Republic of Co., Ltd. Branch
P. O. Box 300201, CONDITION:
Plant -Dangjin Factory Riyadh 11372, Office No. All type/design and routine/sample tests shall be
18, Commercial Complex conducted at SEC approved independent
317, Simin Daero, Dongan-gu Building, King Abdulaziz laboratory in presence of representative of 3rd
Rd. Exit 5, Kingdom of party inspection agency & three engineers of
Anyang-si Saudi Arabia SEC for first contract.
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com WARRANTY:
Phone - +82 2 316 9190 Ten (10) years extended warranty/guarantee in
Email ID - janghee@taihan.com respect of defects due to design, manufacture,
Contact Person Email ID - installation & workmanship from the date of
janghee@taihan.com Provisional Acceptance Certificate (PAC) of the
Website - www.taihan.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Website - http://www.alcatel.fr/
2. 6 Page 54 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.transcanadawireandcable. Including Joints & Terminations
com
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
2. 6 Page 55 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.ffcpg.com.my/
Total = 9
CONDUCTOR, INSULATED
2. 7
POWER CABLE, LPOF, CU, 1-CORE,380 kV Applicable Standards: 11-TMSS-03
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Including Joints & Terminations.
KOREA, Republic of Co., Ltd. Branch
P. O. Box 300201, CONDITION:
Plant -Dangjin Factory Riyadh 11372, Office No. All type/design and routine/sample tests shall be
18, Commercial Complex conducted at SEC approved independent
317, Simin Daero, Dongan-gu Building, King Abdulaziz laboratory in presence of representative of 3rd
Rd. Exit 5, Kingdom of party inspection agency & three engineers of
Anyang-si Saudi Arabia SEC for first contract.
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com WARRANTY:
Phone - +82 2 316 9190 Ten (10) years extended warranty/guarantee in
Email ID - janghee@taihan.com respect of defects due to design, manufacture,
Contact Person Email ID - installation & workmanship from the date of
janghee@taihan.com Provisional Acceptance Certificate (PAC) of the
Website - www.taihan.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Website -
http://www.hitachi-?cable.co.jp/en/inde
x.html
Website -
http://www.mitsubishi-cable.co.jp/inde
x e.html
2. 7 Page 56 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.swcc.co.jp/eng/index.htm
Website - http://www.alcatel.fr/
2. 7 Page 57 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Website - http://www.ffcpg.com.my/
2. 7 Page 58 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Including Joints & Terminations.
Plant -Gumi/Korea
WARRANTY:
13 F Ls Tower ,127, Ls-Ro, Ten (10) years extended warranty/guarantee in
Dongan-Gu, Anyang-Si, Gyeonggi-Do, respect of defects due to design, manufacture,
Korea installation & workmanship from the date of PAC
of the First turnkey project in case of contract
Contact Person - Jiyup Baik award or date of the First delivery in case of
Phone - +82-544697602 directmaterial supply order.
Email ID - nayuppie@lscns.com
Website - http://www.lscns.com
Total = 16
CONDUCTOR, INSULATED
2. 8
MEDIUM VOLTAGE POWER CABLE -XLPE –13.8 kV Applicable Standards: 11-TMSS-04
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution KEMA, Netherlands Including Joints & Terminations
KOREA, Republic of Co., Ltd. Branch (Nov. 2007)
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
2. 8 Page 59 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 8 Page 60 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Gaon Cables CO., LTD. Abdulaziz M. AlSuwaiket MV Power Cable up to 1000 mm² Type Tests PQ letter:
SOUTH KOREA (AlSuwaiket) conducted in KEMA Based on S&SD letter # 18-01986-030504401
AlSuwaiket during 01 to 09 dated May 24, 2018 for Gaon Cables. Gunpo,
Plant -Gunpo +966-13-857-1155 March 2018 Korea is pre-qualified for Medium Voltage Power
abdulaziz@alsuwaiket.c Report no 01 14440 Cables as conforming to latest National Grid SA
120, LS-ro 45beon-gil, Gunpo-si, om A (by SGS) specification # 11-TMSS-04, with the following
Gyeonggi-do, 15841, Republic of Korea conditions:
SAUDI CABLE
Saudi Arabia
Jeddah
2. 8 Page 61 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
LS PREVIOUSLY LG
SOUTH KOREA Including Joints & Terminations
Website - http://www.lscable.com/
2. 8 Page 62 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
muscat
Website -
http://www.omancables.com/
2. 8 Page 63 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
2. 8 Page 64 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. Up to 630 mm2 KEMA – Netherlands PQ Letter
Ltd Up to 13.8kV during April 15, 2016
Saudi Arabia to May 31, 2016. Based on S&SD Letter # 16-07712-1-30504401
Report No.: 1261-16 dated October 04, 2016, Bahra Advanced Cable
Po Box 5989 Jeddah 21432 , Saudi & 1257-16 for single Manufacture Co. Ltd – Jeddah KSA is
Arabia core & Multi Core pre-qualified for MV Cables as conforming to
Medium Voltage National Grid SA Specification # 11-TMSS-04 with
Contact Person - Mr. Loai Taha Al-Bar, Cables. the following conditions:
Sale Manager
Phone - +966-2-591-1115 • Ten (10) years extended warranty from the
Email ID - Loai.albar@bahra-cable.com date of PAC of the first turnkey project (in case
of contract award) or date of first delivery (in
case of direct material supply order), as
confirmed through Bahra Advanced Cable
Manufacture Co. Ltd – Jeddah KSA letter # nil
dated September 06, 2016.
Plant -jeddah
jeddah
Total = 12
2. 8 Page 65 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CONDUCTOR, INSULATED
2. 9
MEDIUM VOLTAGE POWER CABLE - XLPE , 33 & 34.5 kV Applicable Standards: 11-TMSS-04
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed at: Including Joints & Terminations
KOREA, Republic of Co., Ltd. Branch KEMA,
P. O. Box 300201, Netherlands
Plant -Dangjin Factory Riyadh 11372, Office No. (Dec. 1986)
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
2. 9 Page 66 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Gaon Cables CO., LTD. Abdulaziz M. AlSuwaiket MV Power Cable up to 1000 mm² Type Tests PQ letter:
SOUTH KOREA (AlSuwaiket) conducted in KEMA Based on S&SD letter # 18-01986-030504401
(AlSuwaiket) during 01 to 09 dated May 24, 2018 for Gaon Cables. Gunpo,
Plant -Gunpo +966-13-857-1155 March 2018 Korea is pre-qualified for Medium Voltage Power
abdulaziz@alsuwaiket.c Report no 01 14440 Cables as conforming to latest National Grid SA
120, LS-ro 45beon-gil, Gunpo-si, om A (by SGS) specification # 11-TMSS-04, with the following
Gyeonggi-do, 15841, Republic of Korea conditions:
2. 9 Page 67 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SAUDI CABLE
Saudi Arabia
Jeddah
2. 9 Page 68 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.lscable.com/
muscat
Website -
http://www.omancables.com/
2. 9 Page 69 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.swcc.co.jp/eng/index.htm
Website - http://www.ffcpg.com.my
Email ID - lang=en
Website -
http://www.mkm-?mediline.de/index.ph
p/edv-und-software-?entwicklung/mkm
-computer-network-?ungarn?lang=en?
2. 9 Page 70 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
Bahra Advance Cable Manufacture Co. Up to 630 mm2 KEMA – Netherlands PQ Letter
Ltd Up to 33kV during April 15, 2016
Saudi Arabia to May 31, 2016. Based on S&SD Letter # 16-07712-1-30504401
Report No.: 1261-16 dated October 04, 2016, Bahra Advanced Cable
Po Box 5989 Jeddah 21432 , Saudi & 1257-16 for Single Manufacture Co. Ltd – Jeddah KSA is
Arabia Core & Multi Core pre-qualified for MV Cables as conforming to
Medium Voltage National Grid SA Specification #11-TMSS-04 with
Contact Person - Mr. Loai Taha Al-Bar, Cables. the following conditions:
Sale Manager
Phone - +966-2-591-1115 • Ten (10) years extended warranty from the
Email ID - Loai.albar@bahra-cable.com date of PAC of the first turnkey project (in case
of contract award) or date of first delivery (in
case of direct material supply order), as
confirmed through Bahra Advanced Cable
Manufacture Co. Ltd – Jeddah KSA letter # nil
dated September 06, 2016
2. 9 Page 71 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Plant -jeddah
jeddah
Total = 18
CONDUCTOR, INSULATED
2. 10
Distributed Temperature Sensing (DTS) System for U/G Power Cable Applicable Standards: 11-TMSS-06
2. 10 Page 72 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
AP SENSING GmbH Adwan Marketing N43, N44 & N45 Series DTS units Type test performed PO Letter
GERMANY Company in Keysight Based on S&SD Letter No. 16-01996-1-30504401
PO Box: 64273, Riyadh technologies dated 21 March 2016, AP Sensing Gmbh
Plant -Boblingen Germany 11536, Kingdom of Saudi Deutschland GmbH Boblingen, Germany is Pre-qualified for
Arabia Germany hardware Distributed Temperature sensing (DTS) with the
Herrenbergerstr 130 71034 B +966 11495 5332 ext 112 test center following condition.
Boblingen Germany sohail@adwanmarketing Herrenberger Strabe
.com 130 70034 Extended Warranty:
Contact Person - Mr. Mujaheed Ahmed Boblingen . Test Ten (10) Years extended warranty as confirmed
Phone - Tel: +49 7031 309 6610 Fax: report No. through AP SENSING Letter No. Nil dated 28 Feb
+49 7031 309 6611 GHTC-2015-005-TI 2014 shall be applicable for all supplies made to
Email ID - dated 05-02-2015 the company by the Manufacturer.
anja.kammier@apsensing.com, accredited by
info@apsensing.com DAKKS Deutsche
Contact Person Email ID - Akkreditierungsstelle
mujaheed.ahmed@apsensing.com D-PL-19882-01.
Website - www.apsensing.com
Yokogawa Electric Corporation Yokogawa Saudi Arabia DTSX200 and DTSX3000 Yokogawa Electric PQ Letter
JAPAN Company, Saudi Corporation, Japan Based on S&SD letter # 17-02871-5-30504401
Arabia-Dhahran has successfully dated April 19,2017 , Yokogawa Electric
Plant -Japan Ibn Rushd Street, completed type tests Corporation, Japan is pre-qualified for Distributed
Dhahran Techno-Valley - on Distributed Temperature Sensing System (Type: DTSX200
Yokogawa Manufacturing Corporation Dhahran, P.O.Box 3368, Temperature and DTSX3000) as conforming to National Grid
Koufu Factory 155, Takamurocho, Al-Khobar 31952, Sensors (DTS) Type SA specification # 11-TMSS-06, with the
Kofu-City, Yamanashin 400-8558- Kingdom of Saudi Arabia DTSX200 and following conditions:
Japan +966 (13) 331 9600 DTSX3000 in
Hazem.Hassan@sa.yok presence of three WARRANTY:
Kofu ogawa.com SEC/National Grid Ten (10) years extended warranty in respect of
SA Engineers and defects due to design, manufacturing and
Contact Person - Mr. Teichi Matsumoto third party inspector workmanship from the date of PAC of the first
& Mr. Hazem A. Hassan at Independent turnkey project (in case of contract award) or
Phone - +81-55-243-0480 testing laboratory UL from the date of first delivery (in case of direct
Email ID - – Japan on 30 May material supply order), as confirmed, through
Hazem.Hassan@sa.yokogawa.com 2016 & Yokogawa their Letter No. SSD-PDZZ21-G15-25-3 dated
Contact Person Email ID - Electric Corporation 20/01/2016.
Hazem.Hassan@sa.yokogawa.com Laboratory- Japan
Website - WWW.yokogawa.co.jp during 26 to 27 May
2016.
Total = 2
2. 10 Page 73 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CONDUCTOR, INSULATED
2. 11
DTS System Integration, Assembly and Factory Acceptance Testing (FAT) Applicable Standards:
WARRANTY
Ten (10) years extended warranty in respect of
defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), as confirmed, through
their Letter No. NIL dated 13/10/2016.
Total = 1
CONDUCTOR, INSULATED
2. 12
POWER AND/OR CONTROL CABLES COPPER OR ALUMINUM CONDUCTOR 600/1000V Applicable Standards: 11-TMSS-10
RATING
2. 12 Page 74 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
United Cable Industries Company Low Voltage Cables (1X630mm2 0.6/1 kV PQ Letter
(UCIC) Cu/XLPE/AWA/PVC & 48x2.5 mm2 Based on S&SD letter #MPQ1359162-Class I(b)
Jordan Cu/PVC/SWA/PVC). -1x630mm2: Type -2017 dated July 29, 2021, the manufacturer is
Tests successfully prequalified for LV power & Control Cables as
Plant -Jordan completed at DEKRA confirming to National Grid SA specification
- Report# - #11-TMSS-10, with the following conditions:
Zarka-Mafraq Highway Thaghret Aljob 2253356.51-CAT
Jaber Highway Mafraq dated 11-May-2021 WARRANTY
Ten (10) years extended warranty from the date
Contact Person - Mr. E.Marwan -48x2.5mm2: Type of PAC of the first turnkey project (in case of
Karawan , QA/QC Section Head Tests successfully contract award) or date of first delivery (in case
Phone - 00962-6-5549292 completed at DEKRA of direct material supply order), as confirmed,
Email ID - m.karwan@uciccables.com - Report# - through their Letter #Nil dated January 23, 2018,
Website - http://www.uciccables.com 2253356.52-CAT shall be applicable for the equipment to be
dated 11-May-2021 supplied to SEC/National Grid SA.
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Tests performed
KOREA, Republic of Co., Ltd. Branch (March 2008)
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
2. 12 Page 75 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Gaon Cables CO., LTD. Abdulaziz M. AlSuwaiket LV Power and/or Control Cable up to Type Tests PQ letter:
SOUTH KOREA (AlSuwaiket) 630 mm² conducted in KEMA Based on S&SD letter # 18-01986-030504401
(AlSuwaiket) during 01 to 09 dated May 24, 2018 for Gaon Cables. Gunpo,
Plant -Gunpo +966-13-857-1155 March 2018 Korea is pre-qualified for Low Voltage Power &
abdulaziz@alsuwaiket.c Report no 01 14440 Control Cables as conforming to latest National
120, LS-ro 45beon-gil, Gunpo-si, om B (by SGS) Grid SA specification # 11-TMSS-10, with the
Gyeonggi-do, 15841, Republic of Korea Report no 01 14440 following conditions:
C (by SGS)
Contact Person - 1.SeongJun Kim WARRANTY:
(GAON CABLE CO., LTD.) Ten (10) years extended warranty/guarantee in
Phone - +82-2-6921-3880 respect of defects due to design, manufacture,
Email ID - kimsj1@gaoncable.com installation and workmanship from the date of
Contact Person Email ID - Provisional Acceptance Certificate (PAC) of the
kimsj1@gaoncable.com first turnkey project in case of contract award or
Website - www.gaoncable.com date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 12, 2016.
2. 12 Page 76 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SAUDI CABLE
Saudi Arabia
Jeddah
2. 12 Page 77 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website -
http://www.mesccables.com/
2. 12 Page 78 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
BELDEN
United States
Website - http://www.belden.com/
MIDDLE EAST SPECIALIZED CABLE CO. Previously JORDAN NEW CABLE COMPANY-
MESC, JORDAN-
JORDAN AMMAN [The name has been changed based on
S&SD/P&SFD letter # 14-01869-30504401 dated
Jordan March 24, 2014].
2. 12 Page 79 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
TEKAB CO. LTD. LV Power & Control Cables upto 630 TEKAB Certificate # PQ letter:
United Arab Emirates mm² Size with Copper Conductor ( TCL/TTC-1810300 Based on S&SD letter# 13-07588-30504401
except clause 4.3.5c for corrugated dated 16.10.2018 dated December 11, 2013 & S&SD letter#
Sharjah , United Arab Emirates armors) for LV Power Cable 18-4055-01-30504401 dated November 04, 2018,
KEMA TEST REPORT it is pre-qualified for Power and/or Control Cable
Website - http://www.tekab.com/ # 1633-17 dated Copper 600/1000 Volts for All LV power & control
22.01.2018 for LV cables upto 630 mm² size
Power Cable
KEMA TEST REPORT WARRANTY:
# 3188-17 dated Ten (10) years extended warranty/guarantee in
25.06.2018 for LV respect of defects due to design, manufacture,
Control Cable installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #0580/SO/13, dt: Nov 17, 2013
Bahra Advance Cable Manufacture Co. Low Voltage Cables (1X630mm2 & KEMA –Netherland PQ Letter
Ltd 4x300 mm2 CU/XLPE/PVC-FR 1KV) & during 18th to 25th Based on S&SD letter # 15-01562-1-30504401
Saudi Arabia April 2014 & dated March 18 2015 nd S&SD letter #
KINECTRICS-Canada 16-00558-1-30504401 dated February 15 2016,
Po Box 5989 Jeddah 21432 , Saudi during 18th to 24th the manufacturer is prequalified for LV power
Arabia Aug 2014 Report cables with the following condition:
No.TIC 1018-14 for
Contact Person - Mr. Loai Taha Al-Bar, multi-core power WARRANTY:
Sale Manager cable, TIC 1019-14 Ten (10) years extended warranty/guarantee in
Phone - +966-2-591-1115 for single-core respect of defects due to design, manufacture,
Email ID - Loai.albar@bahra-cable.com power cable installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
through their letter # (BCC/AQ/GSM/MZ dated
August 20,2011) for LV cables and letter # ( 1005
/ BH / 2016 dated 14/02/2016) for control cable.
2. 12 Page 80 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Plant -jeddah
jeddah
Total = 15
CONDUCTOR, INSULATED
2. 13
SHIELDED INSTRUMENTATION CABLE Applicable Standards: 11-TMSS-11
Website -
http://www.mesccables.com/
2. 13 Page 81 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
BELDEN
United States
Website - http://www.belden.com/
TEKAB CO. LTD. Instrumentation Cables without Metallic KEMA TEST REPORT PQ letter:
United Arab Emirates Sheath # 3187-17 dated Based on S&SD letter# 18-4055-01-30504401
25.06.2018 for LV dated November 04, 2018, it is pre-qualified for
Sharjah , United Arab Emirates Instrumentation instrumentation Cables without Metallic Sheath
Cables
Website - http://www.tekab.com/ WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
2. 13 Page 82 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
ALPHA
United States
Website - http://www.alpha.com/
AT & T
United States
Website - http://www.att.com/
Total = 6
CONDUCTOR, INSULATED
2. 14
EARTHING AND BONDING CABLE Applicable Standards: 11-TMSS-12
2. 14 Page 83 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SAUDI CABLE
Saudi Arabia
Jeddah
RIYADH CABLES
Saudi Arabia
Plant -Riyadh
2. 14 Page 84 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.ffcpg.com.my/
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Plant -Gumi/Korea
2. 14 Page 85 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. i. Coaxial Bonding Cable 600/1000V Type test report #TIC PQ Letter
Ltd & 1800/3000V up to 500mm2 1019-14 conducted Based on S&SD letter # 17-00912-1-30504401
Saudi Arabia ii. Single Core Bonding Cable in KEMA-Netherland. dated February 16, 2017, BAHRA ADVANCE
600/1000V & 1800/3000V up to 500 CABLE MANUFACTURE Co. Ltd –JEDDAH, KSA is
Po Box 5989 Jeddah 21432 , Saudi mm2 pre-qualified for the proposed Coaxial Bonding
Arabia iii. Earthing Cable 600/1000V & and Earthing Cable as conforming to National
1800/3000V up to 500 mm2 Grid SA specification # 11-TMSS-12 rev.0, with
Contact Person - Mr. Loai Taha Al-Bar, the following conditions:
Sale Manager
Phone - +966-2-591-1115 WARRANTY:
Email ID - Loai.albar@bahra-cable.com Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their letter # Nil, dated October 25, 2016
shall be applicable for all proposing Coaxial,
Bonding Earthing Cable to be supplied to
SEC/National Grid SA.
2. 14 Page 86 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
Total = 9
CONDUCTOR FITTINGS
3. 1
LINE HARDWARE Applicable Standards: 12-TMSS-01
HUBBELL POWER SYSTEMS, INC. Previously A B CHANCE [The name has been
United States changed based on S&SD/P&SFD letter#
14-010193-30504401 dated January 06, 2015
Plant -Columbia , United States and based on Hubbell Power System Grid Letter
# Nil dated December 18, 2014]
ALCOA
United States
Website -
http://www.alcoa.com/usa/en/home.as
p
JOSLYN
United States
Website -
http://www.joslynhivoltage.com/
Website - http://www.iselfa.it/
3. 1 Page 87 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
SA RA ENERGY, CONSTRUCTION, Line Hardware up to 380kV & Tests performed at: Based on S&SD letter# 14-09052-01-30504401
TRADE AND INDUSTRY CO. INC. Twin Spacer Dampers up to 132kV Veiki-VNL Lab. dated 11th December 2014 ,TS&SD fax #
TURKEY Budapest, Hungary 09-00087-03032301 dated 11/01/2009
(Corona/RIV, Power pre-Qualified for Line Hardware up to 380kV and
Plant -Polatli (Ankara) & Adana Arc & Tensile Twin Space Damper up to 132kV with the
(Aadna), Turkey Strength with following conditions:
4-bundle ACAR &
2-bundle ACSR/AW
Conductors WARRANTY:
(Dec. 2012 & April, Ten (10) years extended warranty/guarantee in
2013) respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order
3. 1 Page 88 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
A SALVI & C S.r.l Line Hardware up to380 kV - Tests performed Previous location was "Italy", the location has
FRANCE - Spacer Damper type (Twin) with at: SVEPPI, been change to "France" based on letter #
drawing #3931B456D9277 Rev.0 DEMONT, VEIKI 20-00200-030504401 dated 21.1.2020.
Le Chambon plant, France - Spacer Damper type (Quad) with (2013) Report # RP
drawing # 3931QS456D927 Rev.0 LS 13/131, RP LS
Contact Person - Mr. Giovanni Sangalli 13/202E, 7307/VNL,
(Technical Manager) 7117/VNL, RP LS
Phone - +3902.376715.1, Fax +39 13/127C&D, RP LS
02.376715.222 13/202 A&D, 14/035,
Email ID - salvi@salvi.eu 14/059, 14/037 &
Contact Person Email ID - 14/052-1
sangalli.lab@salvi.eu - Type tests were
Website - http://www.salvi.eu conducted on
spacer dampers
(Nut Cracker type)
at ( Salvi, Italy &
EGU HV Lab, Czech
),from 21/11/2016G,
to 25/11/2016G. with
test report No.
16/110,10549/A/16,
and 10549/B/16 .
CAROBENI
ITALY
3. 1 Page 89 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
PROIZVODNJA MK I OSO d.o.o Innovative Systems Line Hardware up to Tests performed at: PQ Letter
CROATIA (isys) 380 kV Koncar Based on TS&SD fax # 10-01179-03032301
PO Box 60606 Riyadh Croatia, EGU Czech dated April 20, 2010, this manufacturer is
Croatia, Europe, Vukomericka 9, 10410 11555,KSA Republic, pre-qualified for Line Hardware except Spacer
Velika Gorica Zagreb , Croatia/Hrvatska Phone - ZKU, KERI & Bazet Dampers with the following conditions:
+966-11-460-8161 HV
Contact Person - Mr. Davor Maljkovic, Email - kamal@isys.sa Laboratories WARRANTY:
B.Sc. M.E. Ten (10) years extended warranty/guarantee in
Phone - +385 1 62 29 900 respect of defects due to design, manufacture,
Email ID - installation & workmanship from the date of
davor.maljkovic@dalekovod.hr Provisional Acceptance Certificate (PAC) of the
Website - first turnkey project in case of contract award or
http://www.dalekovod-proizvodnja.co date of first delivery in case of direct material
m , http://www.dalekovod.hr supply order.
3. 1 Page 90 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
3. 1 Page 91 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
NUOVA ELETTROMECCANICA SUD Dopa Co. for Trading and - Line Hardware upto 380kV Some of tests PQ Letter
S.P.A, industry - Spacer Damper type (Twin) with mutually ageed Based on S&SD letter # 15-06603-030504401
ITALY Al Nuzha District Riyadh, drawing # 8.40.N2.888 Rev.05 between National dated August 13, 2015 it is pre-qualified for
Saudi Arabia P.O Box - Spacer Damper type (Quad) with Grid SA & NES were Hardware Fittings, as conforming to National Grid
Zona Industriale - 89052 Campo 87017 Code No. 11462 drawing # 8.40.N4.864 Rev.05 conducted during SA specification12-TMSS-01 with the following
Calabro (Rc) - Italy Mr. Abdullah Alabdullah plant survey visit conditions:
Deputy General Manager from 8th to 11th
Phone - +39 0965.792.111 (6 line) - Email/ June, 2015. NOTE:
Telefax +39 0965.792.222 alabullah@dopacompany Each new design of Line Hardware & Fittings
Email ID - info@nesspa.it .com which has not been tested before, shall be type
Website - http://www.nesspa.it (+966) 11 2694609 , Type tests were tested per latest revision of 12-TMSS-01.
Mobile:(+966) 50 conducted on
4449933 spacer dampers WARRANTY:
(Nut Cracker type) Ten (10) years Extended Warranty from the date
at NES Factory Italy of PAC of the first turnkey project in case of
and Demont contract award or date of first delivery in case of
Laboratory, Italy direct material supply order shall be applicable for
from 24th July to the Line Hardware to be supplied to SEC/National
28th July, 2016 with Grid SA, as confirmed through letter # Rome,
Test Report No. TR dated 14.11.2014.
SPAT 16/024, dt:
July, 2016
3. 1 Page 92 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
3. 1 Page 93 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
PREFORMED LINE PRODUCTS (PLP) M/s Al Abdulkarim - AGS Suspension Clamp & Spacer Type tests PQ Letter
United Kingdom Holding Co. Riyadh Damper(Twin/Quad) up to 380 kV performed during Based on S&SD letter # 15-09419-1-30504401
Riyadh KSA - Spacer Dampers type (Quad) with plant survey visit dated November 18, 2015, it is pre-qualified for
East Portway, Andover, Hampshire drawing # SDNCU 8044527V Rev. E from 08th to 11th AGS Suspension Clamp & Spacer Damper
Sp10 3Lh England September 2015 at (Twin/Quad) up to 380KV as conforming to
pip@preformed-gb.com Preformed Line National Grid SA specification # 12-TMSS-01.
Product Lab
Contact Person - Mr. Mohamed Atif and Hampshire, England WARRANTY:
Mr. Stephen (Report Ten (10) years extended warranty from the date
Email ID - alahmama@naizak.com, #TR(GB)No:3060) , of PAC of the first turnkey project in case of
ttaljaard@preformed-gb.com # TR- 3061 Rev.2) & contract award or date of first delivery in case of
alshihzm@akh.com.sa 8730/VNL. direct material supply order.
Website - http://www.preformed.com
Type tests were
conducted on
spacer dampers
(Nut Cracker type)
at PLP (GB) Ltd. ,
ANDOVER UK, from
31 Oct 2016,to 1st
Nov 2016.with test
report No. TR(GB)
No. 3314-E dated
1st Nov 2016 ,TR
(GB) No. 3312-E
dated 31 Oct 2016
and TR(GB) No.
3313-E dated 31 Oct
2016.
SICAMEX
FRANCE
Website - http://
http://www.sicame.com/HTML
FR/filiales sicamex.htm
3. 1 Page 94 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
INDUSTRIAS ARRUTI
SPAIN
Website -
http://www.grupoarruti.com/empresa.a
sp
POWER TRANSMISSION AND Nutcracker Type Quad Spacer Damper Type Tests PQ Letter
TELECOMMUNICATION EQUIPMENTS Drawing No.182 954-454 Performed: Based on S&SD 18-02112/02-30504401 dated
FACTORY (P.T.E. CO.) (CEPCO) VEIKI Test Report # October 01, 2019, the manufacturer is
Saudi Arabia Nutcracker Type Twin Spacer Dampers 10876/VNL dated prequalified for Spacer Damper and Stockbridge
Drawing No.182 954-114 & 182 15-07-2019 Vibration Damper as conforming to National Grid
Plant -Jeddah Industrial City : P.O Box 954-115 SGS Inspection SA specification # 12-TMSS-01 Rev.02, with the
8234 Jeddah 21482 Plant: Plot No. Report # 109556 following conditions:
1&2, Al-Mahjar Street, Industrial
Laboratory: EGU HV CONDITION:
Marketing Office: Type test Report : Fresh Type Tests shall be conducted on
M/s Pfisterer Switzerland 11576/21 dated Stockbridge Vibration Damper and each new
Werkstrasse 7, 6102 Malters, Schweiz, 22-01-2021 design of Spacer Dampers per latest standard
Switzerland 12-TMSS-01 at an independent testing laboratory
in the presence of (03) SEC/National Grid SA
Contact Person: representatives and one approved third party
Mr. Thomas Bachmann inspector during first SEC/ National Grid SA
Phone: +41 41 499 7407 project/ order and all cost pertaining to tests shall
Cell: +41 79 686 3691 be borne by the manufacturer. This has been
thomas.bachmann@pfisterer.com confirmed in writing by the manufacturer through
letter # PTE/TT/SDSD-190909 dated 16
Jeddah September 2019.
Total = 18
3. 1 Page 95 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
CONDUCTOR FITTINGS
3. 2
COMPRESSION TYPE CONNECTORS FOR OVERHEAD TRANSMISSION LINES Applicable Standards: 12-TMSS-02
ALCOA
United States
Website -
http://www.alcoa.com/usa/en/home.as
p
Website - http://www.iselfa.it/
3. 2 Page 96 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
3. 2 Page 97 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
Website - http://www.smci-fc.fr/
A SALVI & C S.r.l Type test lab: Salvi Previous location was "Italy", the location has
FRANCE test lab, Le been change to "France" based on letter #
Chambon France. 20-00200-030504401 dated 21.1.2020.
Le Chambon plant, France Date of Tests: 21st
to 22nd October
Contact Person - Mr. Giovanni Sangalli 2019.
(Technical Manager)
Phone - +3902.376715.1, Fax +39
02.376715.222
Email ID - salvi@salvi.eu
Contact Person Email ID -
sangalli.lab@salvi.eu
Website - http://www.salvi.eu
CAROBENI
ITALY
3. 2 Page 98 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
3. 2 Page 99 of 681
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS (DATE,TEST APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) LABORATORY, WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LOCATION AND
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, REPORT NUMBER)
ETC. AND NAME OF AUTHORIZED
NUOVA ELETTROMECCANICA SUD Dopa Co. for Trading and Overhead Line Compression type PQ Letter
S.P.A, industry connectors Based on S&SD letter # 15-06603-030504401
ITALY Al Nuzha District Riyadh, dated August 13, 2015 it is pre-qualified for
Saudi Arabia P.O Box Overhead line compression type Connectors, as
Zona Industriale - 89052 Campo 87017 Code No. 11462 conforming to National Grid SA specifications #
Calabro (Rc) - Italy Mr. Abdullah Alabdullah 12-TMSS-02
Deputy General Manager
Phone - +39 0965.792.111 (6 line) - Email/ Note:
Telefax +39 0965.792.222 alabullah@dopacompany Each new design of Overhead Line Compression
Email ID - info@nesspa.it .com type Connectors which has not been tested,
Website - http://www.nesspa.it (+966) 11 2694609 shall be type tested as
,Mobile:(+966) 50 per latest revision of 12-TMSS-02.
4449933
WARRANTY:
Ten (10) years Extended Warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order shall be applicable for
the Compression type Connectors, to be supplied
to SEC/National Grid SA as confirmed through
letter # Nil dated 14.11.2014.
Werkstrasse 7
6102 Malters
Schweiz
SICAMEX
FRANCE
Website - http://
http://www.sicame.com/HTML
FR/filiales sicamex.htm
BURNDY
United States
Website -
http://portal.fciconnect.com/portal/page/
portal/FcicntPublic/BurndyWeldMenu
ABB Installation products INC Ahmed Hussain Shaik. ; Previously ELASTIMOLD [The name has been
United States Product Marketing changed based on letter # 19-02239-30504401
Manager dated 02.09.2019].
Plant -Hackettstown +966 122242700 Ext.
2708; +966 59 4788038
1 Esna Drive. ZIP Code 07840 Ahmed.hussain@sa.abb
.com
Hackettstown, New Jersey
HOMAC
United States
Website - http://www.homac.com/
INDUSTRIAS ARRUTI
SPAIN
Website -
http://www.grupoarruti.com/empresa.a
sp
Total = 17
CONDUCTOR FITTINGS
3. 3
OBSTRUCTION MARKERS AND WARNING LIGHTS Applicable Standards: 12-TMSS-03
Website - http://www.smci-fc.fr/
Website -
http://www.bpsarabia.com.sa/
OBSTA
FRANCE
Website - http://www.obsta.com
P&R TECHNOLOGIES
United States
Website - http://www.pr-tech.com/
Website - http://www.pfisterer.com/
Website -
http://www.tanawiremarker.com/
DERVAUX
FRANCE
Website -
http://www.dervaux-distribution.fr/
Total = 8
CONDUCTOR FITTINGS
3. 4
Splice & Termination Kits for Power Cable up to 132 KV Applicable Standards: 12-TMSS-10
ABB
SWITZERLAND
2. Transformer Termination :
3. Outdoor Termination:
DRAKA NK
FINLAND
Website - http://www.draka.com/
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
SUDKABEL Mass Power Contracting Termination ( Dry Type Plugin) Type Tests PQ Letter
GERMANY Co. successfully Model: EHFV 170
Unit 2, Building 6429, a. Model Name: EHSVS 123 (A) completed at (IPH Based on S&SD Letter # 21-01247-30504401
Website - http:// Sybawyah Street, Drawing No. : 0.360.88.1a Berlin - Germany) – dated November 23, 2021, Manufacturer is
http://www.suedkabel.de/index e.htm Al-Dana District, Size : Up to 1600 mm² from 10/08/2020 to pre-qualified for Splice & Termination Kits for
Dammam, Saudi Arabia Rating : 123 kV 17/03/2021, Test Power Cable up to 132 KV as conforming to
report No. National Grid SA Specification # 12-TMSS-10 with
Mr. Syed Ali Baqar b. Model Name: EHSVS 123 (B) (11293-20-0478-1). the following conditions:
(Director Business Drawing No. : 0.360.88.1a
Development) Size : 630 to 2500 mm² CONDITION:
+966-13-8462336/ Rating : 123 kV Approved model subject to successfully
+966-50-6818743 performing the salt Fog Test to be witnessed by
s.ali@mass-group.net c. Model Name: EHSVS 123 (A) approved 3rd party inspector
Drawing No. : 0.360.88.7a
Size : Up to 1600 mm² Warranty:
Rating : 123 kV Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
d. Model Name: EHSVS 123 (B) contract award) or date of first delivery (in case
Drawing No. : 0.360.88.7a of direct material supply order). as confirmed,
Size : 630 to 2500 mm² through their letter No. Nil dated June 05, 2021,
Rating : 123 kV shall be applicable for the equipment to be
supplied to SEC/National Grid SA.
e. Model Name: EHSVS 145 (A)
Drawing No. : 0.360.88.1a
Size : Up to 1600 mm² PQ Letter
Rating : 145 kV Based on S&SD letter # OMPQ4580213-Class I(a)
-2018 dated August 15, 2021, the manufacturer
f. Model Name: EHSVS 145 (B) is prequalified for Splice & Termination Kits for
Drawing No. : 0.360.88.1a Power Cable up to 132kV confirming to National
Size : 630 to 2500 mm² Grid SA specification # 12-TMSS-10 with the
Rating : 145 kV following conditions:
Rating : 123 kV
Rating : 145 kV
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
3. Transformer Termination:
Model Name : SOA 1.145
Rating: 145kV
9. Transformer Termination
(Fluid-Filled):
Model Name : STY1.145
Rating: 145kV
Drawing # OTSF31005
Rating: 145kV
NKT (COLOGNE PLANT)NKT CABLES METS Riyadh 1. Outdoor Termination: Type test witnessed PQ Letter
GROUP Mr. Won Koo Kown Model Name : FEV 170-P during 03rd-7th Based on S&SD letter # 15-05202-01-30504401
GERMANY General Manager Size : Up to 2500 mm² November 2014 & 8 dated
,wkkwon@mets.com.sa Drawing # : 3. 7 5056-04 August,2014 and 14 September 15, 2015, it is pre-qualified as per
Düsseldorfer Strasse 400 Chempark nelson@mets.com.sa Rev: 1 July 2015. KEMA 12-TMSS-10.
51061 Cologne Germany Rating: 170kV Nederland
Test Report WARRANTY:
Phone - +49-0-221-6-760 2. GIS Termination: No1211-15 Ten (10) Extended Warranty/Guarantee for the
Email ID - info@nktcables.com , Model Name : SEV 170 proposed 132 kV cables accessories shall be
saud.khalid@nktcable.com Size : Up to 2500 mm² provided in respect of the defectsdue to design,
Website - http://www.nktcable.com Drawing # : 3. 7 0264-01 manufacturing, installation and workmanship from
Rev: 1 the date of Provisional Acceptance Certificate
Rating: 170kV (PAC) of the project (in case of contract award)
and from the date of delivery for the direct
3. Transformer Termination: material supply order as confirmed through the
Model Name : TEV 170 manufacturer letter # nil dated June 04, 2013.
Size : Up to 2500 mm²
Drawing # : 3. 7 0263-01
Rev: 1
Rating: 170kV
Drawing # : 3. 7 8122-01
Rating: 145kV
PFISTERER IXOSIL 1. Outdoor Termination: Type tests were PREVIOUSLY SEFAG IXOSIL
SWITZERLAND Model Name: ESP 145 conducted in KEMA
Size : Up to 2500 mm² laboratory –
Plant -Pfisterer Ixosil Rating: 145kV Netherland from
Altdorf/Switzerland 09.05.2012 to
2. Outdoor Termination: 19.08.2012.
Pfisterer Ixosil Ag Gotthardstrasse 31 Model Name: ESP 170 (SGS Type Test
Ch-6460 Altdorf Switzerland Size : Up to 2500 mm² Report 01.13288.02
Rating: 170kV Rev.2 dated 20th of
Contact Person - Mr. Nicolas September 2012)
Stocker/Ms Monika Haensli, Sales and
Project Management 3. GIS Termination:
Email ID - Nicolas.stocker@ixosil.ch Model Name : ESG 123-V
Website - http://www.ixosil.ch Size : Up to 2500 mm²
Drawing # : PRO2235
Rev: 2
Rating: 123kV
4. GIS Termination:
Model Name : ESG 145-V
Size : Up to 2500 mm²
Drawing # : PRO2225 Rev: 7
Rating: 145kV
5. GIS Termination:
Model Name : ESG145-V
Size : Up to 2000 mm²
Drawing # : PRO2236Rev: 6
Rating: 145kV
6. GIS Termination:
Model Name : ESG 170-V
Size : Up to 2000 mm²
Drawing # : PR02227
Rev: 5
Rating: 170kV
7. Transformer Termination:
Model Name : ESU-123-V
Size : Up to 2500 mm²
Rating: 123 kV
8. Transformer Termination:
Model Name : ESU-145-V
Size : Up to 2500 mm²
Rating: 145 kV
Drawing # : PRO00324
Rev: 5
Rating: 145kV
Rev. 01
Rating: 123 kV
RAYCHEM, GERMANY / TE
CONNECTIVITY
GERMANY
Website - http://www.raychem.com/
2. Transformer Termination :
Drawing # : S1929-4
Size : 240 mm² to 1200 mm²
Rating : 170 kV
3. Outdoor Termination:
6. Transition Joint:
DAITWEILER
United Kingdom
Website - http://www.duttweiler.de/
Website - http://www.ffcpg.com.my/
ABB Installation products INC 1. Cross Bonding Joint: Previously ELASTIMOLD [The name has been
United States Model Name : 138TCJS4 changed based on letter # 19-02239-30504401
dated 02.09.2019].
Plant -Hackettstown 2. Cross Bonding Joint:
Model Name : 138TCJS46
1 Esna Drive. ZIP Code 07840 Size : Up to 1200mm²
Drawing # : SD-SEC-1200mm2
Hackettstown, New Jersey Rating: 145kV
Taihan Electric Wire Co. 1.GIS Termination (Dry Type Plugin): Type tests were PQ Letter:
Saudi Arabia Model Name : GPPS-145-L conducted in KERI Based on S&SD letter # 18-04569-01-30504401
Drawing # : EBG-132-PPS01 laboratory – South dated December 11, 2018, Taihan Electric Wire
Plant -Riyadh Korea. Test Report Co. – Saudi Arabia, Riyadh is pre-qualified for
2.GIS Termination (Fluid Filled) : No. 2019TC00095 132kV Cable Splice & Termination Kits as
Riyadh, Kingdom of Saudi Arabia Model Name : GMFS-145-O dated 04.04.2019. conforming to National Grid SA specification #
P.O. Box 519- Riyadh 11383 Size : 200-1600 mm2 (SGS Type Test 12-TMSS-10, with the following condition:
Drawing # : EBG-132-S02 Rev: A Report 01.14842
Contact Person - Mr. Seung IL, Kim Rev.01 dated Warranty:
(General Manager) 3.GIS Termination (Fluid Filled) : 01.04.2019)” Ten (10) years extended warranty/guaranty
Phone - +966 593 836 444; Model Name : GMFS-145-O from the date of (PAC) of the Turnkey project (In
Email ID - sikim@taihan.com; Size : 1600 ~ 2500 mm² case of contract award) and from the date of
Website - www.sauditaihan.com Drawing # : EBG-132-S03 Rev: A delivery for the direct material supply order. The
guarantee/warranty shall be applicable from first
4.Transformer Termination (Fluid Filled) project and shall cover all the cost of materials
: and labor as per warranty/guarantee of materials
Model Name : OMFS-145-O and workmanship and subsequently reduced
Size : 200 ~ 1600 mm² yearly in case of future project award. This was
Drawing # : EBO-132-S02 Rev. A confirmed in writing by Taihan Electric Wire Co.,
Riyadh, Saudi Arabia through their letter #
5.Transformer Termination (Fluid Filled) STL-091/17/K dated # August 28, 2017.
:
Model Name : OMFS-145-O
Size : 1600 ~ 2500 mm²
Drawing # : EBO-132-S03 Rev. A
6.Outdoor Termination:
Model Name : AMPS-145-66
Size : 200 ~ 2500 mm²
Drawing # : EBA-P132-S01 Rev. A
7.Insulation Joint:
Model Name : SMI-145-CS
Size : 200 ~ 2500 mm²
Drawing # : PMJ-132-IJC-CS Rev. A
PFISTERER Kontaktsysteme GmbH M/s CEPCO Civil & 132KV HV Connex Plug in Dry Type PFISTERER PQ letter:
GERMANY Electrical Projects termination size 6 (including socket) Kontaktsysteme Based on S&SD letter # 17-07474-2-30504401
Contracting Co. with drawing # 866999999A1.3 Rev GmbH-Germany dated November 01, 2017, PFISTERER
Plant -GERMANY P.O Box 8234, Jeddah .01 successfully Kontaktsysteme GmbH-Germany is pre-qualified
21482, KSA conducted type for 132KV Plug-in Dry Type GIS termination
Rosenstrasse 44 73650 Winterbach +966 26634331 tests on 132KV HV conforming to latest National Grid SA
m.yamout@cepco-sa.co Connex 6 GIS Plug in specification # 12-TMSS-10, with the following
Winterbach m Dry Type termination conditions :
(including socket) in
Contact Person - Mr. Andre Goessler, independent test WARRANTY:
Sales Manager & Mr.Stephane wope, laboratory Ten (10) years extended warranty/guarantee in
Technical Advisor (KEMA-Netherland respect of defects due to design, manufacture,
Phone - +49718170050 with report # TIC installation and workmanship from the date of
Email ID - 1072-12) in the Provisional Acceptance Certificate (PAC) of the
Andre.Goessler@pfisterer.de, presence of first turnkey project in case of contract award or
Stephane.Wope@pfisterer.com SEC/National Grid date of first delivery in case of direct material
Website - www.Pfisterer.de SA Engineers & supply order, as confirmed by the manufacturer
Third Party inspector vide letter # Nil, dated October 24, 2016.
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 1. GIS Termination:
KOREA, Republic of Co., Ltd. Branch Model Name : GMF-123-O
P. O. Box 300201, Size : 200-1600 mm2
Plant -Dangjin Factory Riyadh 11372, Office No. Drawing # : EBG-115-S
18, Commercial Complex Rev: A
317, Simin Daero, Dongan-gu Building, King Abdulaziz Rating: 123kV
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia 2. GIS Termination:
+966 11 410 1773 Model Name : GMF-123-O
Contact Person - Jang Hee Lee hslee0822@taihan.com Size : 1600-2500 mm2
Phone - +82 2 316 9190 Drawing # : EBG-115-S01
Email ID - janghee@taihan.com Rev: A
Contact Person Email ID - Rating: 123kV
janghee@taihan.com
Website - www.taihan.com 3. GIS Termination:
Model Name : GMF-145-O
Size : Up to 1200 mm²
Drawing # : EBG-132-S
Rev: A
Rating: 145kV
4. GIS Termination:
Model Name : CVC-GWO-110-BD
Size : Up to 2500 mm²
Rev: A
Rating: 123kV
5. GIS Termination:
Model Name : CVC-GWO-132-BD
Rating: 145kV
6. Outdoor Termination:
Model Name : AMP-145
Rating: 145kV
7. Outdoor Termination:
Model Name : CVC-APS-1322000A-BD
Rating: 145kV
8. Outdoor Termination:
Model Name : CVC-APS-1322410A-BD
Size : Up to 2500 mm²
Rev: A
Rating: 145kV
Rating: 145kV
Total = 20
CONDUCTOR FITTINGS
3. 5
Splice & Termination Kits for Power Cable up to 230 KV Applicable Standards: 12-TMSS-10
ABB AG
GERMANY
BRUGG 1. Porcelain Outdoor Termination Type test performed Models are accepted and uploaded as per the
SWITZERLAND in DNV-GL (KEMA)– range of type approval of IEC 62067.
a. Model Name: TE1.245-11 Netherland testing
Contact Person - Mr. Amr Soudi; Size: Up to 2500 mm² laboratory, report WARRANTY:
Regional Sales Manager Drawing Number : S1947-4 #1821-18 & Ten (10) years extended warranty/guarantee in
Phone - +41 79 9135155 Date: 29.03.20 2123-18, respect of defects due to design, manufacture,
Email ID - Prequalification Test installation & workmanship from the date of
rolf.aregger@bruggcables.com b. Model Name: TE1.245-12 performed in Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - Size: Up to 2500 mm² DNV-GL (KEMA) – first turnkey project in case of contract award or
amr.soudi@bruggcables.com Drawing Number : S1948-4 Netherland testing date of first delivery in case of direct material
Website - www.bruggcables.com Date: 29.03.2019 laboratory, report supply order.
#1702-19.
c. Model Name: TE1.245-13
Size: Up to 2500 mm²
Drawing Number : S1949-4
Date: 29.03.2019
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Berlin , Germany
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 230 kV Tests performed at: WARRANTY:
KOREA, Republic of Co., Ltd. Branch KEMA Ten (10) years extended warranty/guarantee in
P. O. Box 300201, Netherlands respect of defects due to design, manufacture,
Plant -Dangjin Factory Riyadh 11372, Office No. installation & workmanship from the date of
18, Commercial Complex Provisional Acceptance Certificate (PAC) of the
317, Simin Daero, Dongan-gu Building, King Abdulaziz first turnkey project in case of contract award or
Rd. Exit 5, Kingdom of date of first delivery in case of direct material
Anyang-si Saudi Arabia supply order.
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
Total = 10
CONDUCTOR FITTINGS
3. 6
Splice & Termination Kits for Power Cable up to 380 KV Applicable Standards: 12-TMSS-10
VISCAS FUJIKURA
JAPAN
Website - http://
http://www.viscas.com/e contact.html
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
3. Cross-bonding Joint
Model Name: MPSP 1.420-31
Drawing Number: S1458-4
Date: 10.12.2013
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
LS CABLES & SYSTEMS LTD. 380 kV cable Tests performed at PREVIOUSLY LG;
SOUTH KOREA 1. Outdoor Termination KEMA
1x2500 mm2, CU/XLPE/LEAD/PE Netherlands (Aug,
Contact Person - Mr. H.S.JO (General a. Model Name: UEMA40Q004, 2014 to PQ Letter
Manager) Mr. Young Min Seo b. Model Name: UMEMA40Q004 from Dec, 2014) Based on S&SD letter # 15-3193-30504401 dated
Email ID - symsky@iscns.com PPC insulators (Germany). Test Report Nos. May 03, 2015, the manufacturer is prequalified to
Website - http://www.lscable.com/ ? 1066-14 & TIC supply the Power Cables & Accessories with the
2. Transformer Termination 1564-14 specified designations only:
a. Model Name: WC-114022 with
Drawing # WC-114022 rev. 00 Tests performed at WARRANTY:
KEMA , Netherlands Ten (10) years extended warranty/guarantee in
3. GIS Termination (Dry Type) (5th of July to 1st of respect of defects due to design, manufacture,
a. Model Name: UEPG40Q001 with Dec, 2021) Test installation & workmanship from the date of
Drawing # UEPG40Q001 rev. 00 Report No. 1603-21. Provisional Acceptance Certificate (PAC) of the
b. Model Name: UEPG40Q003 with first turnkey project in case of contract award or
Drawing Number: UEPG40Q003 date of first delivery in case of direct material
supply order.
4. Cross Bonding Joint
a. Model Name: UEMK40Q002 with Based on S&SD letter #22-00873-30504401
Drawing # UEMK40Q002 rev. 00 dated July 21, 2022, the manufacturer is
prequalified for Splice & Termination Kits for
Note: For all future SEC/National Grid Power Cable up to 380 KV as confirming to
SA projects/direct purchase orders, National Grid SA specification # 12-TMSS-10,
porcelain bushings for outdoor with the following conditions:
terminations shall be procured from our
approved list. WARRANTY
ILJIN ELECTRIC CO. LTD. Dopa Co. for Trading and 380kV Based on S&SD letter# 16-2299-02-30504401
SOUTH KOREA industry 1. Outdoor Termination: dated May 02, 2016, it is prequalified for380kV
Al Nuzha District Riyadh, a. Model Name : APS(CE-W) 420-S, Accessories [Outdoor Termination-Porcelain Type
Plant -South KOREA Saudi Arabia P.O. Box with Drawing # : APS(CE-W)420-S rev. APS(CE-W) 420-S, Outdoor Termination-Porcelain
87017 Code No. 11462 1 Type APWA(CE-W) 420-S, Dry Type GIS
905-64, Mannyeon-ro, Hwaseong-si, Mr. Abdullah Alabdullah b. Model Name : APWA(CE-W) 420-S, Termination GDEO(CE-W) 420S, Premold
Gyeonggi-do Email / with Drawing # : APWA (CE-W) 420-S Insulation Joint Type MIDFD(CE-W) 420-S,
alabdullah@dopacompan rev. 1 Premold Straight Joint Type MNDFD(CE-W) 420-S]
Contact Person - Mr. Tony Lim, Mr. y.com 2. GIS Termination (Dry Type ) with the following conditions:
Daniel Park TEL / (+966) 11 2694609 a. Model Name : GDEO(CE-W) 420S,
Phone - +82-2-707-9253 , Mobile / (+966) with Drawing # : GDEO(CE-W)420-S • Ten (10) years extended warranty from the
Email ID - yeongchang.lim@iljin.co.kr; 504122831 rev. 1 date of PAC of the turnkey project in case of
daniel.park@iljin.co.kr 3. Cross Bonding Joint: contract award and date of delivery in case of
a. Model Name: MIDFD(CE-W)420-S, direct material supply order, as confirmed by the
with Drawing #: MIDFD(CE-W)420-S manufacturer through letter # ILJHC-160412 A
rev. 0 dated 12/04/2016.
4. Straight Through Joint:
a. Model Name: MNDFD(CE-W) 420-S,
with Drawing #: MNDFD(CE-W)420-S
rev. 0
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution 380 kV Tests performed at: PQ Letter
KOREA, Republic of Co., Ltd. Branch 1x2500mm2 KEMA Based on S&SD letter # 14-08139-01-30504401
P. O. Box 300201, Netherlands (Jan. dt: January 07, 2015, the manufacturer is
Plant -Dangjin Factory Riyadh 11372, Office No. 1. Outdoor Termination 2014 to prequalified to supply power cables &
18, Commercial Complex a. Model Name: May, 2014) accessories with the specified designations only:
317, Simin Daero, Dongan-gu Building, King Abdulaziz CVC-APS-3804605N-BD rev. A Report # TIC
Rd. Exit 5, Kingdom of 3094-14 WARRANTY:
Anyang-si Saudi Arabia 2. GIS termination (Fluid-Filled ) Ten (10) years extended warranty in respect of
+966 11 410 1773 a. Model Name: CVC-GWO-380-BD rev. the defects due to design, manufacturing,
Contact Person - Jang Hee Lee hslee0822@taihan.com A installation and workmanship from the date of the
Phone - +82 2 316 9190 Provisional Acceptance Certificate (PAC) of the
Email ID - janghee@taihan.com 3. GIS termination (Dry Type) first turnkey project (in case of contract award)
Contact Person Email ID - a. Model Name: CVC-GWBS-380-BD or from the date of first delivery in case of direct
janghee@taihan.com rev. A material supply order shall be provided as
Website - www.taihan.com confirmed by the manufacturer through their
4. Transformer Termination letter # Nil dated September 02, 2014.
a. Model Name: CVC-OWO-380-BD
with Drawing # WD-433884 rev. 01
Total = 11
CONDUCTOR FITTINGS
3. 7
LINK BOXES FOR GROUNDING OF U/G POWER CABLE Applicable Standards: 12-TMSS-11
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
AARTCO UP TO 230KV.
Saudi Arabia
Website - http://www.aartco.com.sa/
Plant -Riyadh
EM ELEKTRIK MALZERMELERI Gulf Trade Link Est. Type tests were PQ Letter
YUKLENIM SAN.TIC. A.S. PO Box 20362 Riyadh conducted in KEMA Based on S&SD letter # 15-07259-2-30504401 dt:
TURKEY 11455 Netherland in Sept17, 2015, the manufacturer is prequalified to
Mr. Ahmed Qazi presence of supply Link box, Up to 132kV with Stainless Steel
(Itosb)No:25 34959 Tepeören-Tuzla Commercial Manager SEC/National Grid Material as conforming to National Grid SA
Istanbul / Turkey ahmed@gradelink.com SA Engineers during specification # 12-TMSS-11
1st to 5th June
Phone - +90 216 593 37 15 & 2015.This Test was WARRANTY:
19(Pbx),Fax: +90 216 593 37 21 repeated on this link Ten (10) years extended warranty in respect of
Email ID - info@emelec.com.str box during 30th the defects due to design, manufacturing,
June and 1st July installation and workmanship from the date of the
2015 in DNV-GL . Provisional Acceptance Certificate (PAC) of the
Type Test Report No. project (in case of contract award) and from the
1206-15 VI, 1207-15 date of delivery in case of direct material supply
VI, 1208-15 VI, order shall be provided as confirmed by the
1209-15 VI manufacturer through their extended warranty
letter attached with the letter #EM-011-/031 dated
January 25, 2012.
STEINER
GERMANY
Website -
http://www.steiner-binoculars.com/ind
ex.html
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Plant -Gumi/Korea
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
Website - http://www.ffcpg.com.my/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Total = 13
CONDUCTOR FITTINGS
3. 8
Splice and Termination for Medium Voltage Power Cables Applicable Standards: 12-TMSS-04
Type Tests
successfully
completed at
Prysmian Lab -
Report#
RQ-R&D-ELAB-ET-1
5-156 dated
29-April-2016. for
the following
termination:
-Model:
CDTO-1C-35-Nd-T3
E~I (Drawing No.
42118, Rev. A)
-Model:
CDTO-3C-35-Nd-T3
E~I (Drawing No.
42118, Rev. A)
-Model:
CDTO-1C-35-Ne-T3
E~I (Drawing No.
42119, Rev. A)
-Model:
CDTO-3C-35-Ne-T3
E~I (Drawing No.
42119, Rev. A)
50 Up to 500 mm2 (AL) No. 02/G276 than 400 mm², it shall be type tested with the 1st
5.a Tests performed project.
3. Straight Plug Termination at University of
a. Model Name: SEHDG23 Karlsruhe (May
Drawing No. : 100.310.32 1996) Test Report
Rev.1 Nos. 96035
Voltage Rating: 13.8 kV 5.b Tests performed
Size : 50 Up to 185 mm2 (CU) at University of
70 Up to 240 mm2 (AL) Karlsruhe (Sep.
2010) Test Report
4. Elbow Plug Termination Nos. 2010-27
a. Model Name: SEW24 5.c Tests performed
Drawing No. : 100.310.126 at University of
Rev.6 Karlsruhe (July
Voltage Rating: 13.8 kV 2003) Test Report
Size : 50 mm2 (CU) Nos. 2003-52
70 mm2 (AL) 5.d Tests performed
at University of
b. Model Name: SEHDW21 Karlsruhe (May
Drawing No. : 100.310.25 1996) Test Report
Rev.4 Nos. 96035
Voltage Rating: 13.8 kV 5.e Tests performed
Size : 120 mm2 (CU) at University of
Karlsruhe (Sep.
5. Inner Cone Plug Termination 2010) Test Report
a. Model Name: SEIK23 Nos. 2010-27
Drawing No. : 100.310.71 5.f Tests performed
Rev.15 at University of
Voltage Rating: 13.8 kV Karlsruhe (July
Size : 50 Up to 240 mm2 (CU) 2003) Test Report
70 Up to 240 mm2 (AL) Nos. 2003-52
Total = 5
INSULATORS
4. 1
INSULATORS, STATION POST TYPE, PORCELAIN, INDOOR/OUTDOOR, 69 KV THROUGH 380 Applicable Standards: 15-TMSS-01
KV
LAPP INSULATORS REDWITZ GMBH
GERMANY
Website - http://www.lappusa.com/
Website - http://www.wsi.com/
Rating: 380kV
Model: #7.036021.01.01.00
PPC INSULATORS (ELEKTROKERAMIK Rating: 132kV - Model 12134-518400 132kV: EGU Report Previous location was "Austria", the location has
SONNEBERG) Rating: 230kV - Model 12134-718100 no. 11382/A/20; PPC been changed to "Germany" based on
GERMANY Rating: 380kV - Model 12145-939600 Report MV manufacturer letter # Nil dated July 7, 2020
2883/2020
Plant -Sonneberg 230kV: EGU Report WARRANTY:
no. 11382/B/20; PPC Ten (10) years extended warranty from the date
Werkingstrasse 11, 96515 Report MV of PAC of the first turnkey project (in case of
Sonnenberg/Germany 2882/2020 contract award) or date of first delivery (in case
380kV: EGU Report of direct material supply order). as confirmed,
Contact Person - Mr. J.Gebhart no. 11382/C/20; PPC through their letter No. Nil dated 7 July 2020, shall
Phone - +49 3675 8730 Report MV be applicable for the equipment to be supplied to
Email ID - 2881/2020 SEC/National Grid SA.
Johannes.gebhart@ppcinsulators.com,
info@eks-son.de
Website -
https://www.ppcinsulators-eks.com/en
/
Total = 6
INSULATORS
4. 2
INSULATORS, PORCELAIN SUSPENSION TYPE UP TO 380kV Applicable Standards: 15-TMSS-02
NGK INSULATORS LTD Mitsubishi Corporation Porcelain Fog type Disc Insulator Tests performed:
JAPAN 5h Floor tower A4, Models: May 25-June 01,
Granada Business park 132 kV 111KN 2011, March 01-13,
Plant -Aichi Japan, Exit 9 CA-825MW 2007, and March
Phone - CA-825EZ, 20-22, 2007
Contact Person - Mr. H. Nakane & Mr. Y +966-11-511-7516
Ogawa Email: hashim.a.ibrahim@ 132 kV 160KN Report # 110023T,
Email ID - n111ex@ngk.co.jp & mitsubishicorp.com CA-839MX 110024T,
ogawa@ngk.co.jp CA-839EX,
Website - http://www.ngk.com/ 070011T, 070012T,
380 kV 160 KN 120025T,
CA833MZ
CA833EX, 080027T, 080030T,
080031T
380 kV 210 KN
CA845MY 110021T, 110022T,
CA-845 EZ,
380 kV,160 KN
CA-635MZ
CA-635EZ
CA-635EW
380 kV,210 KN
CA640MY, CA640EY
Total = 1
INSULATORS
4. 3
INSULATORS, GLASS, SUSPENSION TYPE TYPE UP TO 380kV Applicable Standards: 15-TMSS-02
YuAIZ AO – Yuzhnouralsk Insulators Energy Engineer Toughened Glass Insulators U120AD, Power Arc Tests PQ Letter
and Fitting Plant AL (JSC) Establishment Riyadh U120BP, U160AD, U160BP, U210AD, Performed: Based on S&SD letter# 19-00094-30504401
Russian Federation (EEE) U210BP VEIKI Test Report # dated January 20, 2019, the manufacturer is
Abdullah Fahhad K. 9356/VNL dated July prequalified for Toughened Glass Insulators up to
Plant -Chelyabinsk Al-Jofan (General 19-21, 2016. 380KV as confirming to National Grid SA
Manager) (U210AD) specification # 15-TMSS-02, Rev.01, with the
1 , Zavodskaya Street Yuzhnouralsk, 00966-544002245 VEIKI Test Report following conditions:
Chelyabinsk Region 457040, Russia gm@energieee.com #9357/VNL dated
July 22, 2016 CONDITIONS
Contact Person - Mr. Vladimir (U160BP) Power Arc Test shall be performed on each
Kuznetsov VEIKI Test Report production lot at time of actual supply for models
Phone - +735134-98-5-64 #9359/VNL dated U120AD & U120BP based on S&SD letter #
July 22, 2016. 21-00175-2021 dated 04/02/2021.
(U120BP) Remaining Type & Special Tests which were not
VEIKI Test Report conducted during prequalification stage shall be
#9360/VNL dated performed on the first production lot of each type
July 22, 2016 of insulator at the time of actual supply (e.g., Low
(U120AD) Frequency Flashover, Critical Impulse, RIV,
Kema Test Report Thermal Shock, Residual Strength, Impact
DNV-GL # 5314-18 Strength, Cotter Key, Mechanical Failing Load,
dated November 02, Thermal Mechanical Performance & Pollution
2018 (U160AD) Tests etc.)
Kema Test Report All costs related to inspection & witnessing
DNV-GL # 5315-18 above mentioned tests by SEC/National Grid SA
dated November 02, engineers & Independent Inspection Agency (in
2018 (U210BP) case of contract award or direct purchase
orders shall be borne by the manufacturer.
Steep Manufacturer’s improvements /corrective
Front-of-Wave Test measures will be evaluated during sample testing
Performed: for first project supply order.
Kema Test Report
DNV-GL # 1724-18 WARRANTY
dated November 03, Ten (10) years extended warranty from the date
2018 (210BP) of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
OAO "YuAIZ of direct material supply order), as confirmed,
Factory Test Report through their Letter No. Nil dated 09/01/2019 shall
# 5601-122-2018 be applicable for the equipment to be supplied to
dated July 02 to 07, SEC/National Grid SA.
2018 (Mechanical
Failing Load,
Thermal Mechanical
Performance &
Steep Wave Front
Tests for U160AD &
U210BP)
Test Report #
5601-71-2019 dated
July 29, 2019 &
5601-73-2019 dated
August 02, 2019
VERESCENCE La Graja SL Innovative Systems Toughened Glass (Aero form/Fog) Tests performed at: PQ Letter
SPAIN (isys) 120kN, 160KN, and 210kN EGU & ZKU labs Based on S&SD letter# 13-07206-01-30504401
PO Box 60606 riyadh Models: (Czech republic). dated November 09, 2013, it is pre-qualified for
Sgd La Granja Vidrieria, S. L. Paseo Del 11555 KSA E-120DZ-146 (March 4-15, 2013) Glass insulators with the following condition:
Pocillo S/N 40100 B Granja De San Phone - E-160GDZ-146
Ildefonso (Segovia) Spain Segovia , +966-11-460-8161 E-210GDZ-170 Report # 9886/A/13, WARRANTY:
Spain Email - kamal@isys.sa E-120PPZ-146 9886/B/12, Ten (10) years extended warranty/guarantee in
E-160PZ-156 9886/D/13, and respect of defects due to design, manufacture,
Contact Person - Mr. Elias Py Rodriguez E-210PZ-170 13/044 installation & workmanship from the date of
Phone - +(+34) 917707516 E-120DZ-127 Provisional Acceptance Certificate (PAC) of the
Email ID - insulators@sgdgroup. corn first turnkey project in case of contract award or
Website - date of first delivery in case of direct material
http://www.sgdinsulators.com supply order, as confirmed by the manufacturer
thru letter #nil, dt: Nov 08, 2012.
Total = 3
INSULATORS
4. 4
INSULATORS, PORCELAIN HORIZONTAL LINE POST TYPE Applicable Standards: 15-TMSS-03
Total = 3
INSULATORS
4. 5
INSULATORS, PORCELAIN, LONG ROD TYPE UP TO 380 kV Applicable Standards: 15-TMSS-04
Zapel SA Innovative Systems 132kV Long Rod Porcelain Insulators Type test performed PQ Letter:
Poland (ISys) 160KN at KEMA Laboratory Based on S&SD letter # 17-04625-01-030504401
P.O.Box 60606, Riyadh Dwg. # 032Z-15 & 033Z-15 Prague dated June 07,2017, Zapel SA Poland is
Plant -Poland 11555 120KN Report# 5024-17 & pre-qualified for 132kV Long Rod Porcelain
Dwg. # 158Z-15 & 159Z-15 5025-17 dated Insulators as conforming to National Grid SA
Zapel SA Techniczna 1 36-40, local Contact Person: 10-03-17 specification # 15-TMSS-04, with the following
Boguchwala, Poland Mr. Kamal Al Muhanna Drawing # 032Z-15 conditions:
Mobil# +966 -505491067 & 033Z-15
Contact Person - Mr. Wojciech Sztaba +966 (11) 4608160, +966 WARRANTY:
Phone - +48178720100 (11) 4608161 Type test performed • Ten (10) years extended warranty from the
Email ID - zapel@zapel.com.pl kamal@isys.sa at EGU HV date of PAC of the first turnkey project (in case
Contact Person Email ID - laboratory Praha of contract award) or date of first delivery (in
Wojciech.Sztaba@zapel.com.pl dated 10.03.2017 case of direct material supply order), as
Website - confirmed, through their Letter No. NIL dated
http://www.zapel.com.pl/en/products/i Report #10573/A/17 30/05/2016 shall be applicable for the equipment
nsulators/ Report #10573/B/17 to be supplied to SEC/National Grid SA.
Report #10573/C/17
Report #10573/D/17
Report #10576/A/17
Report #10576/B/17
Drawing #
032Z-15
033Z-15
159Z-15
158Z-15
032Z-15
033Z-15
132kV, 120 KN
CA45501A
CA45503A
CA45514A
CA45516A
CA45502A
CA45504A
CA45515A
CA45517A
LAPP INSULATORS GMBH • Rating : 160kN Tests performed at: Based on S&SD letter # 18-01028-30504401
GERMANY Material / Drawing Numbers: dated February 27, 2018, Type/Model Rating for
7.012395.00.07.00 / 101.708.00.05; EGU HV LAPP Insulators Germany is updated.
Plant -Bahnhofstrasse 5, 95632 7.012397.00.07.00 / 101.710.00.05; (2009/2010/2011/20
Wunsiedel Germany 7.012724.00.07.00 / 101.740.00.05; 13)
7.012700.01.07.00 / 101.713.01.05; Report #
Contact Person - Mr. i.A. Thomas 7.012725.00.07.00 / 101.741.00.05 01/09, 02/09, 46/13,
Zembsch 41/13, 75a/09,
Phone - +49 (0) 92 32 / 50 15 5 • Rating : 210kN 9763/11, 40/13,
Email ID - Material / Drawing Numbers: 42/11, 21/10,
tzembsch@lappinsulators.com 7.012396.00.07.00 / 101.709.00.05 10129/A/14 dated
Website - July, 2014,
http://www.lappinsulators.com • Rating : 330kN 10614/A/17
Material / Drawing Numbers: (18-02-17),
7.012719.01.07.00 / 101.735.01.05; 10702/B/17
7.012398.00.07.00 / 101.711.00.05; (13-07-17)
7.012716.01.07.00 / 101.731.01.05;
7.012754.01.07.00 / 101.771.01.05 Type tests
7.012753.01.07.00 / 101.770.01.05 performed in
Lapp Germany lab.
(2009-2013)
Lapp Test Report
Nos.01/09, 02/09,
46/13,41/13,
75a/09, 9763/11,
40/13,42/11, 21/10,
40/13, 15/17
(24-01-17),
KEMA DNV-GL:
5275-18 (26-10-18)
Type tests
performed in
EGU Laboratory,
Czech Republic
26.04.2021
Lab Test Report:
11630/A/21 &
11630/B/21
Total = 5
INSULATORS
4. 6
INSULATORS, COMPOSITE, HORIZONTAL LINE POST, SUSPENSION AND TENSION TYPE (UP Applicable Standards: 15-TMSS-05
TO 230 KV)
PFISTERER Insulators Wunseidel GmbH MODULAR DESIGN Type tests Prequalified for MODULAR TYPE DESIGN
GERMANY 115 kV 120/160 kN conducted at LAPP insulators
Germany lab
Plant -Wunsiedel - Germany Model:
14K3349 & 50 Test Report No. Previously "’Lapp Insulators GmbH"
Bahnhofstrasse 5 28/13 & 29/13
95632 Wunsiedel 230 kV
Germany 120/160 kN
E.B. REBOSIO S.R.L MOLDED DESIGN Prequalified for MOLDED TYPE DESIGN insulators
ITALY up to 132 kV
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
-------------
PQ Letter
Based on S&SD letter# 18-03367-02-30504401
dated October 29, 2018 M/s E.B. Rebosio S.r.l,
Italy (previously prequalified up to 132kV) is
prequalified for Composite Suspension and
Tension Insulators up to 230kV as conforming to
National Grid Saudi Arabia Material Specification
15-TMSS-05, Rev.02 with the following condition:
Type Test:
The first project of 230kV Composite Insulators,
per 15-TMSS-05, to be supplied to SEC/National
Grid SA shall be type, special and routine tested
in presence of three (3) SEC/National Grid SA
and one (1) SEC/National Grid SA approved IIA
Inspector as confirmed through Manufacturer
Letter # Nil dated September 13, 2018. All cost of
which shall be borne by E.B. Rebosio S.r.l, Italy.
Warranty
Ten (10) years extended warranty from the date
of PAC of the turnkey project for 230kV in case
of contract award or date of delivery in case of
direct material supply order, as confirmed by the
manufacturer through letter # Nil dated
September 04, 2018.
FCI (FURUKAWA COMPOSITE LSR DESIGN Prequalified for LSR TYPE DESIGN insulators
INSULATORS LTD)
HUNGARY
Budapest , Hungary
Website - http://www.fcifurukawa.hu
MACLEAN POWER SYSTEM MODULAR DESIGN Prequalified for MODULAR TYPE DESIGN
United States insulators
NGK LOCKE INC. Mitsubishi Corporation MOLDED DESIGN Tests performed: Prequalified for MOLDED TYPE DESIGN insulators
United States 5h Floor tower A4, 111 kN,160 kN (2011 & 2012)
Granada Business park Report # 120014T
Virginia Beach, Va, Usa Exit 9
Phone -
Contact Person - Mr. H. Enomoto +966-11-511-7516
Email ID - enomoto@ngk-polymer.com Email -
Website - http://www.ngk-locke.com/ hashim.a.ibrahim@mitsu
bishicorp.com
XIANGYANG GUOWANG COMPOSITE RADYA International Molded Design Prequalifed for MOLDED TYPE DESIGN insulators
INSULATORS CO. PO Box: 61891 Riyadh up to 132 kV only.
CHINA 14211 K.S.A.
+966-11-4966667 WARRANTY:
Plant -Xiangyang city, China. afzal.mohammad@kfbgr Ten (10) years extended warranty/guarantee in
oup.com.sa respect of defects due to design, manufacture,
No.10, Dengman Road, High & New installation & workmanship from the date of
Tech Park, Industry District, Xiangyang, Provisional Acceptance Certificate (PAC) of the
Hubei 441057, P.R China first turnkey project in case of contract award or
date of first delivery in case of direct material
Contact Person - Mr. Wang Xin supply order shall be given for the proposed 132
Phone - Tel: 0086-710-3262531,Fax: kV composite insulators
0086-710-3250621
The warranty/ guarantee shall be applicable from
first project and shall cover all the cost of
materials and labor as per warranty / guarantee
of materials and subsequently reduced yearly in
case of future project award. This was agreed
through the manufacturer letter # GCR-06-02
dated 2015-07-08.
Note:
Previously “XIANGFAN GUOWANG”, the name
has been changed to “Xiangyang Guowang
Composite Insulators Co. Ltd.” based on the
manufacturer letter # RI/PQ/
XYGW/TT132/2015/008 dt: August 09, 2015 and
the supporting documents approved by the
concerned authorities in China.
Total = 6
INSULATORS
4. 7
INSULATORS, COMPOSITE, HORIZONTAL LINE POST, SUSPENSION AND TENSION TYPE (UP Applicable Standards: 15-TMSS-05
TO 380 KV)
PFISTERER Insulators Wunseidel GmbH MODULAR DESIGN Prequalified for modular type design insulators
GERMANY Rating: Tests Performed: CONDITION:
160 kN-380 kV Type tests Any new type of Insulators (other than the types
Plant -Wunsiedel - Germany conducted at LAPP already tested) offered by Lapp, Germany shall
Model – Germany lab, EGU & be Type Tested in presence of three (3) SEC
Bahnhofstrasse 5 Rodurflex CS160SB30/79 ZKU Engineers and one (1) Approved Independent
95632 Wunsiedel (195/163)4900 Agency Inspector.
Germany 7.095670.80.01.00/ Lapp Germany Test
7.095670.80.22.00 Report No. 29/13, dt: WARRANTY:
Wunsiedel - Germany 09/04/2013 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Contact Person - Alexandra Schlecht EGU Test Report installation & workmanship from the date of
Phone - +49718170050 No.9898/A/13 from Provisional Acceptance Certificate (PAC) of the
Email ID - infoholding@pfisterer.com 03/04/2013 to first turnkey project in case of contract award or
Contact Person Email ID - 08/04/2013. date of first delivery in case of direct material
alexandra.schlecht@pfisterer.com supply order
Website - www.pfisterer.com ZKU Test Report No.
13-059, dated:
05/04/2013 Previously "’Lapp Insulators GmbH"
Type Test:
The first project of 380kV Composite Insulators,
per 15-TMSS-05, to be supplied to SEC/National
Grid SA shall be type, special and routine tested
in presence of three (3) SEC/National Grid SA
and one (1) SEC/National Grid SA approved IIA
Inspector as confirmed through Manufacturer
Letter # Nil dated September 13, 2018. All cost of
which shall be borne by E.B. Rebosio S.r.l, Italy
Warranty
Ten (10) years extended warranty/guarantee
from the date of (PAC) of the Turnkey project (In
case of contract award) and from the date of
delivery for the direct material supply order. The
guarantee/warranty shall be applicable from first
project and shall cover all the cost of materials
and labor as per warranty/guarantee of materials
and workmanship and subsequently reduced
yearly in case of future project award. This was
confirmed in writing by E.B.REBOSIO S.r.L, Italy
through their letter # nil dated # September 04,
2018.
MACLEAN POWER SYSTEM Yousif Al Hobays Office MODULAR DESIGN Type tests Prequalified for MODULAR TYPE DESIGN
United States for Trading Service conducted at EGU, insulators
PO Box 301134 Riyadh Model: ZKU,Klokar &
Plant -7801 Park Place Road 11372 Saudi Arabia Cat./Drawing S678192 VG03 KFUPM WARRANTY:
Email:yhobayb@gmail.co Ten (10) years extended warranty/guarantee in
York, South Carolina m EGU Test Report respect of defects due to design, manufacture,
29745, USA No.9447/08 dt: installation & workmanship from the date of
18/11/2008. Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Ms. Anabel first turnkey project in case of contract award or
Gdriozola EGU Test Report date of first delivery in case of direct material
Contact Person Email ID - No.9449/08 dt: supply order, as confirmed by the manufacturer
addriozola@macleanfogg.com 16-17/12/2008 through their letter no.RI/MCLN/SEC/AS, dt: 5th
Website - http:// April, 2007.
http://www.macleanpower.com/ ZKU Test Report No.
08-109, dt:
21/10/2008)
NGK LOCKE INC. Mitsubishi Corporation MOLDED DESIGN Tests performed: Prequlified for MOLDED TYPE DESIGN insulators
United States 5h Floor tower A4, July 01-05, 2008,
Granada Business park 380 kV,178 kN July 25-27, 2011 and PQ Letter
Virginia Beach, Va, Usa Exit 9 April 20-27, 2005 Based on TS&SD letter #
Phone - 402-SL1370-SK-95 10-F02356/02-03032301 dated 22/11/2010, it is
Contact Person - Mr. H. Enomoto +966-11-511-7516 Report # pre-qualified for 380 kV Composite Insulators:
Email ID - enomoto@ngk-polymer.com Email:hashim.a.ibrahim@ 380 kV,222 kN 080022T (For 380
Website - http://www.ngk-locke.com/ mitsubishicorp.com Models: kV, 178 kN WARRANTY:
Insulators) Ten (10) years extended warranty/guarantee in
50B-SL1370-SK-95 110036T & 050028T respect of defects due to design, manufacture,
50B-SL1370-SK-59 (For 380kV, 222kN installation & workmanship from the date of PAC
502-SL1770-SK-95 Insulators) of the turnkey project in case of contract award
502-SE1570-SK-15 or date of delivery in case of direct material
230 kV,160 kN 120014T, supply order.
36B-SS1140-SK-08 PO3031T,
230 kV,111 kN 030058T,
251-SL970-3J-09 TN-NCI-98143
TN-NCI-2000009 R1
132 kV, 160 kN
36B-SS620-SK-0A
132 kV 111 kN
25A-SL540-SJ-0A
115 kV,160 kN
36B-SL510-SK-0A
115 kV,111 kN
25A-SL440-SJ-0A
Total = 5
INSULATORS
4. 8
RTV SILICON RUBBER INSULATOR COATING Applicable Standards: 15-TMSS-07
M/s BRB International Saudi Conduit Coating & BRB Si-COAT 570hs HVIC Type Tests PQ Letter
NETHERLANDS Contracting Company Performed: Based on S&SD letter # MPQ8860314 dated
P O Box 41044, First • EGU Test January 04, 2022, the manufacturer is
Plant -Ittervoort - Netherlands Industrial City, Dammam Report # 11762/21 prequalified for RTV Silicon Rubber Insulator
31521 dated December 20, Coating Material BRB Si-COAT 570hs HVIC as
Europastraat 5 - 6014 CD +966554551283 2021 (Tracking and conforming to National Grid SA specification #
Ittervoort, The Netherlands Hisham.Koya@s3c.com. Erosion / 1000hrs 15-TMSS-07 Rev.01, with the following
sa Salt fog, Tracking conditions:
Ittervoort and Erosion
Resistance and Dry WARRANTY
Contact Person - Marc Ladreyt Arc Resistance) Ten (10) years extended warranty from the date
Phone - +31 646 757 078 • BRB Lab Test of PAC of the first turnkey project (in case of
Email ID - mladreyt@brbbv.com Report # contract award) or date of first delivery (in case
Contact Person Email ID - HVIC570hs-001- of direct material supply order), as confirmed,
mladreyt@brbbv.com 122021 dated through their Letter No. Nil dated September 11,
Website - www.brb-international.com December 02, 2021 2020 shall be applicable for the equipment to be
(Adhesion) supplied to SEC/National Grid SA.
• BRB Lab Test
Report #
HVIC570hs-002-
122021 dated
December 02, 2021
(High Pressure
Water Withstand).
• Material
Xpertise Report #
20211115-1 dated
December 06, 2021
(Contact Angle)
WACKER Chemie AG WACKER Chemicals POWERSIL® N552 Type Tests Based on S&SD letter # 22-00600-30504401
GERMANY Middle East FZE (Local Performed: dated May 19, 2022, the manufacturer is
sales office) prequalified for RTV Silicon Rubber Insulator
Plant -Burghausen, Germany Contact Person: • EGU Report # Coating Material POWERSIL® N552 as conforming
Mohammed Sanaobar 11702/21 dated to National Grid SA specification # 15-TMSS-07
Johannes-Hess-Str. 24 Regional Technical October 04, 2021 Rev.01, with the following conditions:
84489 Burghausen, Germany Director - Dubai (Tracking and
mohammed.sanaobar@ Erosion / 1000hrs • Ten (10) years extended warranty from the
Munich, Germany ( Head office) wacker.com Salt fog) date of PAC of the first turnkey project (in case
Mobile: • CPRI Report # of contract award) or date of first delivery (in
Contact Person - Dr. Martin +971 50 4514272 CPRIBLRHVDMISC20 case of direct material supply order), as
Bortenschlager T0572 dated confirmed, through their Letter No. Nil dated
Phone - +49 8677 83-0 or +49 89 PO Box 341071, Dubai December 29, 2020 March 19, 2020 shall be applicable for the
6279-0 Silicon Oasis (Tracking and equipment to be supplied to SEC/National Grid SA.
Email ID - Dubai - U.A.E. Erosion Resistance)
martin.bortenschlager@wacker.com Tel.: +971 4 709 9999 • CPRI Report #
Contact Person Email ID - Fax: +971 4 709 9911 CPRIBLRCDDMATMI
martin.bortenschlager@wacker.com +971 4 7099999 SC20T0090 dated
Website - www.wacker.com October 15, 2020
mohammed.sanaobar@ (Dry arc
wacker.com Resistance)
• Intertek Report
# IR 03 Rev.02 dated
November 8, 2020
(High Pressure
Water Withstand)
• Intertek Report
# IR 03 Rev.02 dated
November 8, 2020
(Adhesion)
• University of
Applied Sciences
Germany Report #
VB 28/18 dated
December 14, 2018
(Contact Angle)
MIDSUN GROUP, Inc. Desert World Company Midsun HVIC G W/ATH (Part No. Type Tests PQ Letter
United States 122 St., Road# 23,2nd S2622MMS-G-ATH) Performed: Based on S&SD letter # 19-03636-30504401
Industrial City, Dammam, - ITE Test Report # dated December 30, 2019, MPQ110914-Class I(b)
Plant -USA Kingdom of Saudi Arabia IE-ITE-200316-01/M2 -2016 the manufacturer is prequalified for RTV
+966 50262 2222; +966 / EN dated Silicon Rubber Insulator Coating as conforming to
GACO Western Factory (owned by 549228800 September 09, 2021 National Grid SA specification # 15-TMSS-07
Firestone Building ProductsCompany gsarkis@dwc-me.com (Tracking and Rev.01, with the following conditions:
LLC, manufactures RTV Coating for Erosion / 1000hrs
M/s Midsun), 1245 Chapman Drive, Salt fog) WARRANTY
Waukesha, WI 53186, Wisconsin, USA - ITE Test Report # Ten (10) years extended warranty from the date
IE-ITE-200316-02/M2 of PAC of the first turnkey project (in case of
Contact Person - Mr. Robert F. Vojtila / EN dated contract award) or date of first delivery (in case
Phone - +1 860-378-0100 Ext. 112 September 09, 2021 of direct material supply order), as confirmed,
Contact Person Email ID - (Tracking and through their Letter No. Nil dated December 13,
vojtirf@midsungroup.com Erosion Resistance) 2016 shall be applicable for the equipment to be
- ITE Test Report # supplied to SEC/National Grid SA.
IE-ITE-200316-03/M2
/ EN dated
September 09, 2021
(Dry arc
Resistance)
- ITE Test Report #
IE-ITE-200316-04/M2
/ EN dated
September 09, 2021
(High Pressure
Water Withstand)
- ITE Test Report #
IE-ITE-200316-05/M2
/ EN dated
September 09, 2021
(Adhesion)
- ITE Test Report #
IE-ITE-211045/EN
dated December 03,
2021 (Contact
Angle)
CSL SILICONES INC. Saudi Conduit Coating & Si-Coat 570hs “SEC/National Grid SA has decided to accept RTV
CANADA Contracting Company Coating Material from CSL Canada for 6 months
PO Box 41044 only on exceptional basis till the end of January
Plant -Canada First Industrial City 2021”
Dammam 31521
144 Woodlawn Road West Kingdom of Saudi Arabia
+966 13 847 3288
Guelph hisham.koya@s3c.com.s PQ Letter
a Based on S&SD letter# 15-06643-01-30504401
Contact Person - Abdus Samad Hashmi dated August 26, 2015, it is pre-qualified for RTV
- Project Managment Supervisor ; Silicone Rubber Insulator Coating Material
Bharat Poojara - Indigo FZC “Si-Coat 570hs” as conforming to National Grid
Phone - +1 519 836 9044 SA specification # 15-TMSS-07, with the
Email ID - following conditions:
customerservice@cslsilicones.com
Contact Person Email ID - Abdus Samad WARRANTY:
Hashmi: ahashmi@cslsilicones.com ; Ten (10) years extended Warranty for the
Bharat Poojara: proposed RTV Silicone Rubber Insulator Coating
bharat.poojara@indigo-power.com Material “Si-Coat 570hs” in respect of the defects
Website - www.cslsilicones.com due to design, manufacturing and workmanship
from the date of the Provisional Acceptance
Certificate (PAC) of the project (in case of
contract award) and from the date of delivery for
the direct material supply order shall be provided
as confirmed through the manufacturer letter # Nil
dated 05-08-2015.
Total = 5
AL-SALAM INSDUTRIES AND TRADING Only one trial 110/132kV transmission line project
EST./ADVANCE TECHNOLOGIES. only (short line)
Saudi Arabia
DAMMAM
WARRANTY
Ten (10) years Extended Guarantee / Warranty
from the date of PAC of first Project (in case of
contract award) or from the date of delivery for
the direct material supply order,as confirmed
through their Letter # Nil dated 04/01/2015.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
through their letter no. AS/2009/0704/001, dt: 7th
April, 2009..
Email ID - aic@aicsteel.com.
Website - http://www.aicsteel.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
ENERGYA STEEL SOLUTION (HESHAM latticed steel Based on S&SD letter # 15-10909-02-30504401
HELAL EL SEWEDY & PARTNERS FOR structures up to 380 kV dated February 10, 2016 , TS&SD letter#
STEEL INDUSTRIES CO.) 09-2179/07-03032301 dated November 11, 2009,
Saudi Arabia approval of Executive Directive for TS&SD letter#
09-02179/06-03032301 dated November 11, 2009
Rabigh – Yanbu High Way Exit 927 & based on S&SD letter# 13-01978/01-30504401
Industrial Zone Aramco Road dated June 10, 2013, it is pre-qualified for
Contact Person - Mr. Ahmed Khan , Mr. - Substation Steel Structures up to 380 kV
Rayan A. Taj
Phone - +966-5609678655 Tel: +966 - Transmission Towers for projects up to 380
500150706 ,Fax: +966 500576159 kV(Except design)
Email ID - info@energyasteel.com
Contact Person Email ID - and
ahmed.khan@energyaksa.com, - Communication Towers for Transmission
Rayan.Taj@energyasteel.com Sector
,Rayan.Taj@energyaKSA.com
with the following condition:
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order
This was confirmed, through their Letter # nil
dated October 14, 2014.
GEYARD FOR COMMERCE AND IMPORT Prequalified for Substation Steel Structures only
CO.
Saudi Arabia
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Chennai , India
Website -
http://www.larsentoubro.com/
Warranty:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order) as confirmed,
through their letter No. Nil, dated January 05,
2022, shall be applicable for the equipment to be
supplied to SEC/National Grid SA.
Total = 18
HIDADA
Saudi Arabia
PETIT JEAN
FRANCE
Website - http://www.petitjean.fr/uk/ec
gm.php
SUMMIT MANUFACTURING
United States
Pa , United States
Website - http://www.summitmc.com/
TECHNOPALI
ITALY
Website - http://www.technopali.co.uk
VALMONT
United States
Website - http://www.valmont.com/
AL BABTAIN POWER&TELECOM CO
Saudi Arabia
Plant -Riyadh
Riyadh
Total = 7
TECHNO RUBBER COMPANY LTD Duct Sealing Units Type Tests PQ Letter
Saudi Arabia successfully
completed at Al-Hoty Based on S&SD letter # MPQ1111346-Class 1 (a)
Plant -Saudi Arabia Laboratories – -2016-I(b)dated October 29, 2019, the
Dammam, KSA (4 manufacturer is prequalified for Duct Sealing
Dammam, Saudi Arabia July 2019), Bureau Units as confirming to National Grid SA
2ND INDUSTRIAL CITY Veritas Report No. specification # 23-TMSS-02, with the following
12/4072019-01 & conditions:
P.O.BOX 3508 DAMMAM 34326 12/19022018-01
dated 15.7.2019 WARRANTY
Dammam
Ten (10) years extended warranty from the date
Contact Person - Mr. Rajashekaran / of PAC of the first turnkey project (in case of
Mr.Chand Mubarak contract award) or date of first delivery (in case
Phone - +966 13 812 3333 Ext.-215 of direct material supply order), as confirmed,
Email ID - info@technorubber.com.sa through their Letter #Nil dated May 24, 2017, shall
Contact Person Email ID - be applicable for the equipment to be supplied to
raja@technorubber.com.sa / SEC/National Grid SA.
chand@technorubber.com.sa
Website - www.technorubber.com.sa
Website -
http://www.amiantit.com/en/default.php
Total = 3
POWER TRANSMISSION AND Cable Clamps for Power Cables up to CPRI ( Central PQ Letter:
TELECOMMUNICATION EQUIPMENTS 380 kV Power Research Based on S&SD letter # 18-04057-01-30504401
FACTORY (P.T.E. CO.) (CEPCO) Institute ) Report # dated November 11, 2018, Power Transmission
Saudi Arabia CPRIBLRHPL1819T0 and Telecommunication Equipment Factory Co. -
104 dated 16.7.2018 (P.T.E. ..Co.), Jeddah, Saudi Arabia is
Jeddah Industrial City : P.O Box 8234 and Report # pre-qualified for Cable Clamps up to 380kV as
Jeddah 21482 CPRIBLRMEDMISC18 conforming to National Grid SA specification #
19T0014 dated 23-TMSS-04, with the following condition:
Plant: Plot No. 1&2, Al-Mahjar Street, 13.7.2018 for Flat
Industrial Clamps Warranty:
Ten (10) years extended warranty/guaranty
Contact Person - Eng. Mohammad CPRI ( Central from the date of (PAC) of the Turnkey project (In
Saleem Mir (General Manager); Mr. Power Research case of contract award) and from the date of
Faisal Jandali Institute ) Report # delivery for the direct material supply order. The
Phone - +966 1260 95165; +966 595 CPRIBLRHPL1819T0 guarantee/warranty shall be applicable from first
3323 74; +966126608629; 107 dated 16.7.2018 project and shall cover all the cost of materials
+966504661072 and Report # and labor as per warranty/guarantee of materials
Email ID - inquiry@pte-sa.com CPRIBLRMEDMISC18 and workmanship and subsequently reduced
Website - www.pte-sa.com 19T0014c dated yearly in case of future project award. This was
13.7.2018 for Trefoil confirmed in writing by Power Transmission and
Clamps Telecommunication Equipment Factory Co. -
(P.T.E. ..Co.), Jeddah, Saudi Arabia through their
SGS Inspection letter # PTE/PQ/Clamps/2016/L-097R1 dated #
Report # August 13, 2018.
BRD/GHV/34/2018
Total = 2
ISAM M. KHAIRY KABBANI & Type DB, EB, and EPC-40-PVC Type tests PQ Letter:
INSULATION FACTORY COMPANY Conduits conducted at ACES Based on S&SD letter #MPQ4561946-Class IV(b)
Saudi Arabia (Arab Company for -2018_Class I(b) dated April 05, 2022, ISAM M.
Laboratories & Soil), KHAIRY KABBANI & INSULATION FACTORY
Plant -Dammam 2nd industrial City Jeddah, Saudi COMPANY – is pre-qualified for PVC Conduits
Arabia dated August and Fittings for underground Cables as
Street No 95, 7202- Unit No. 3520, Ad 19, August 21, conforming to National Grid SA specification
Dammam 34332-2770 October 19 and 23-TMSS-01, Rev.01, with the following
November 17, 2021 conditions:
Dammam
WARRANTY:
Contact Person - Omar Al-Sasa Ten (10) year Extended Warranty as confirmed,
Phone - +966 138342544 through letter # Nil, dated 06/03/2022 shall be
Email ID - operation.ikkpf@ikkgroup.com applicable for all supplies made by M/S ISAM M.
Contact Person Email ID - KHAIRY KABBANI & INSULATION FACTORY
omar.alsasa@ikkgoup.com COMPANY, DAMMAM, KSA
Website - www.ikkgroup.com
B.C for Manufacturing Plastic Electrical Type DB, EB, and EPC-40 PVC Pipes Type Test Report # PQ Letter
Conduits JPQ22000022 (
Saudi Arabia Tested on March 29, Based on S&SD letter # MPQ12271964-Class
30, 31, 2022, May IV(b)- 2017 dated September 27, 2022, the
Plant -Bahra 28, 2022 & June 28 , manufacturer is prequalified for PVC Conduits &
2022 at ACES Fittings for UG Cables under as confirming to
Bahra – CPC industry area LABORATORY – National Grid SA specification # 23-TMSS-01,
JEDDAH, SAUDI with the following conditions:
Jeddah ARABIA)
Total = 2
Total = 1
WESCOSA
Saudi Arabia
Email ID - aic@aicsteel.com.
Website - http://www.aicsteel.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by Al-Ashouri
Industries through letter # 2010/4-03/0003 dated
01/08/2010.
3M
United States
Website - http://solutions.3m.com/en
US/
AB WIRE
SWEDEN
Website - http://www.moorlink.com/
ABAHSAIN-COPE
Saudi Arabia
Website -
http://www.abahsain.net/Abcope.htm
AL-AMAL CO. Type / Model: FOR LADDERS & Type Tests FOR LADDERS & ACCESSORIES
Saudi Arabia ACCESSORIES conducted in King
Saud University on WARRANTY:
Riyadh, Saudi Arabia 14th July, 2008 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
vide their letter no. IMD-CR-955, dt: October 29th,
2007.
AL-MISBAH HOUSE FOR STEEL Type / Model: Metallic Cable Tray PQ Letter
WORKS Systems Based on TS&SD letter 09-00509/1-03032301
Saudi Arabia dated 16th. March 2009 for Metallic Cable Tray
Rating: Systems.
Riyadh , Saudi Arabia
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
EFCOR
United States
ELECTROLINK CO. LTD. Electrolink Company Type / Model: Metallic Cable Tray PQ Letter
Saudi Arabia Limited Systems Based on TS&SD letter 09-00524/1-03032301
dated 16th. March 2009 for Metallic Cable Tray
Plant -2nd Industrial Area, Riyadh City Rating: Systems.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 2nd Dec, 2012.
HIDADA
Saudi Arabia
Website - http://www.hidada.com.sa/
Website -
http://mecss.com.sa/contact.html
O-Z GEDNEY
United States
Website - http://www.o-zgedney.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #NIL, DT: 15th Jan, 2013.
TOLARTOIS
FRANCE
Website -
http://www.tole-perforee.com
Ba’amer Electric Factory Galvanized Carbon Steel Cable Trays Type Test PQ letter:
Saudi Arabia and Ladders Report/Inspection Based on S&SD letter # 18-01054/01-030504401
Certificate # dated April 24, 2018, for Ba`Amer Electric
Plant -Jeddah, 2nd Industrial City R/013/SA/RYD/18 Factory Jeddah, KSA is pre-qualified for Cable
dated 10.2.2018 Support Systems (Cable Trays, Cable Ladders,
P.O. Box 30066 Jeddah 21477 conducted at Cable Trunking, Strut Metal Framing Etc.) as
Al-Hoty Calibration conforming to latest National Grid SA
Jeddah Services Khobar specification # 24-TMSS-01, Rev.01 with the
KSA following conditions:
Contact Person - Engr. Mohammad
Al-Shareef WARRANTY:
Phone - 012 6610 260 - 012 608 1999 Ten (10) years extended warranty/guarantee in
Email ID - sales2@baamerelectric.com respect of defects due to design, manufacture,
Contact Person Email ID - installation and workmanship from the date of
mohammad@baamerelectric.com Provisional Acceptance Certificate (PAC) of the
Website - www.baamerelectric.com first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated April 05, 2018.
Total = 20
ABB ( T& D)
United States
Website - http://www.abb.us/
ALPHA NIDAU
SWITZERLAND
CONDITION:
All type/special and routine tests for Disconnect
Switches 420kV, 4000A (S3CD, S3CDT &
S3CD2T) only and Standalone Grounding
Switches (STB) 420kV, 63kA only shall be
conducted at in an Independent testing laboratory
on one switch before supplied to SEC system in
the presence of three (3) SEC/National Grid SA
engineers & one (1) National Grid SA approved
independent inspection agency Inspector, all the
related costs for witnessing the tests will be
borne by the manufacturer. This was confirmed
by Alstom Grid S. p .A, ITALY through their letter
# 323/11/C/RP.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #136/11/CO/RP.
EFACEC
PORTUGAL
Website - http://www.hapam.nl/
MG/EGIC
FRANCE
SIEMENS
GERMANY
Website - http://
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx
Website -
http://www.southernstates.com/
S&C
United States
Website - http://www.sandc.com/
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
Total = 12
SUBSTATION PANELS
9. 1
RELAY & CONTROL PANEL Applicable Standards: 31-TMSS-01
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 16th june, 2010.
ABB S.R.O (RFF) ABB Automation Co. Ltd. Type tested in PQ Lettter
CZECH REPUBLIC PO Box.414 Riyadh Independent Lab Based on S&SD letter# 15-09012-1-30504401
11383 EZU Parague, Czech dated November 05, 2015, it is pre-qualified for
Stetkova 1638/18,140 00 Praha 4Czech republic/EVPU Nova Relay & Control Panels as conforming to National
Republic-Trutnov Dubnica, Slovakia on Grid SA specification # 31-TMSS-01, with the
5th to 15th may following condition:
Contact Person - Mr. Essam 2015
Bashraheel & Mr Aref Al-Arrak Report#08.220.985. WARRANTY
Email ID - Ten (10) year Extended Warranty as confirmed
Essam.bashraheel@sa.abb.com through
&Aref.alarrak@sa.abb.com their Letter No. 14-05231-01-30504401 dated
November 10,
2014 shall be applicable for all supplies by ABB
s.r.o (RFF), Trutnov-Czech Republic.
Website -
http://www.kerrcruickshank.com/
KONCAR ELEKTRICNI UREDAJI D.D Nesma Telecom& Rating - upto 380 kv PQ Lettter
CROATIA Technology Co. Ltd. Based on S&SD letter# 14-1456-03-30504401
Jeddah Asfan Road dated April 15, 2014, it is pre-qualified for Relay &
Plant -Zagreb/Croatia - Hrvatska inside azzam compound Control Panel up to 380 kV as conforming to
Tel:012-2727637,Phone - National Grid SA specification # 31-TMSS-01,
Končar-Električni Uređaji D.D. Prisoje 0500000582 with the following condition:
29A, 21232, Dicmo, Hr Email - WARRANTY
nesmaelectric@nesma.c Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Ljubomir Zubčić, om respect of defects due to design, manufacture,
Phone - +385 21 778 512; +385 91 374 installation & workmanship from the date of
2009 ; +385 021 778 516 Provisional Acceptance Certificate (PAC) of the
Email ID - Email first turnkey project in case of contract award or
:ljubomir.zubcic@koncareu.hr date of first delivery in case of direct material
Website - Web: supply order.
http://www.koncareu.hr
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #META/12/AM, dt: Mar 23, 2011.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.nil, dt: 18th July, 2008.
REYROLLE LTD.
United Kingdom
Website -
http://www.reyrolle-protection.com/
Grenoble France
Hitachi Energy Switzerland AB ABB Automation Co. Ltd. Type tested in Mfr. Name change from ABB SWITZERLAND LTD
SWITZERLAND Hitachi Energy Ltd. Independent Lab to Hitachi Energy Sweden AB
Riyadh, Saudi Arabia EZU Parague, Czech
Bruggerstrasse 72, 5400 Baden Republic /EVPU
Nova Dubnica, PQ Lettter
Contact Person - Mr. Ahmed Abubasha, Slovakia on 5th to Based on S&SD letter# 15-09013-1-30504401
Mr. Abdulmajeed Alothman 15th may 2015 dated November 05, 2015, it is pre-qualified for
Email ID - Relay & Control Panels, as conforming to National
Ahmed.abubasha@hitachienergy.com , Report#08.220.986. Grid SA specification # 31-TMSS-01 with the
abdulmajeed.alothman@hitachienergy.c following condition:
om
Contact Person Email ID - WARRANTY
Ahmed.abubasha@hitachienergy.com , Ten (10) years Extended Warranty as confirmed
abdulmajeed.alothman@hitachienergy.c through
om their Letter #14-05230-01-30504401 NIL dated
Website - www.hitachienergy.com 4th November 2014 shall be applicable for all
supplies made by ABB Switzerland Ltd -
Switzerland.
ACRASTYLE
United Kingdom
Website - http://www.acrastyle.co.uk/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #NIL, DT: 03/10/2013.
TIEPCO
Saudi Arabia
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Ingenious Network FZC Power Flow Contracting NGSA-RCP-16001-B / Up to 132KV Ingenious Network PQ Letter
United Arab Emirates Siteen Street, Al-Malaz, FZC- Sharjah, UAE Based on S&SD letter # 17-00160-1-30504401
Dsitrict P.O Box 325917, successfully dated January 19, 2017, Ingenious Network FZC-
Plant -Saif Free Zone, Sharjah, UAE Riyadh-11371, KSA completed type Sharjah, UAE is pre-qualified for Relay & Control
+966 11 4734876 Panels up to 132kV as conforming to National
Q3-047 Sharjah Airport International Rami.azzam@powerflo Grid SA specification # 31-TMSS-01, with the
Free Zone (SAIF Zone) Al Dhaid Road, w-sa.com following conditions:
P.O Box 120110, Sharjah, United Arab
Emirates WARRANTY:
Ten (10) years extended warranty from the date
Sharjah of PAC of the first project (in case of contract
award) or date of first delivery (in case of direct
Contact Person - Mr. Tabish M. Ismail, material supply order), as confirmed, through
Sales & Marketing their Letter No. PQN-SEC-15001-RCP-6A dated
Phone - +971 6 5579471 June 6,2015 shall be applicable for all Relay &
Email ID - Control Panels to be supplied to SEC/National Grid
ahmed.bader@ingenious-network.com SA.
Contact Person Email ID -
tabish.i@ingenious-network.com
Website -
www.ingenious-network.com
Hitachi Energy Ltd. Type/Model - Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.
Plant -2Nd Industrial Area,Riyadh,, Previous name was ABB Electrical Industries
Company Ltd, and change to ABB Contracting Co.
Po Box 325841 Riyadh,11371 KSA Ltd based on S&SD letter #20-01681-30504401
dated October 01, 2020
Riyadh
AREVA
United Kingdom
Website - http://www.areva.com/
Total = 29
SUBSTATION PANELS
9. 2
AUXILIARY AC/DC PANELS Applicable Standards: 31-TMSS-02
Website - http://www.alojaimi.com/Our
Companies/Introduction - Mohammed
Al-Oja/introduction - mohammed
al-oja.html
KONCAR ELEKTRICNI UREDAJI D.D Nesma Telecom & AC Distribution Board , 400/230 V, AC Distribution PQ Letter
CROATIA Technology Co. Ltd. 4500 A, 85kA for 1Sec. and rated Board type test Based on S&SD letter#18-04543-30504401.
(NESMA ELECTRIC) Insulation voltage 1000 V. performed on dated January 02, 2019, the manufacturer is
Plant -Zagreb/Croatia - Hrvatska Asfan Road, Azzam DC Distribution Board , 125 V, 1000A , September 18 to prequalified for AUXILIARY AC/DC PANELS as
Compound Building # 1 25kA for 1Sec. and rated Insulation October 20-2017 in confirming to NG/SEC specification #
Končar-Električni Uređaji D.D. Prisoje P.O. Box 7195, City : voltage 800 V. CESI-IPH Berlin 31-TMSS-02, with the following condition:
29A, 21232, Dicmo, Hr Jeddah,Saudi Arabia Germany testing
+966 5360 24245 , Engr. laboratory Report # WARRANTY
Contact Person - Mr. Ljubomir Zubčić, Ahmed Elafifi 06992-17-0658-2 Ten (10) years extended warranty in respect of
Phone - +385 21 778 512; +385 91 374 ahmed.elafifi@nesma.co DC Distribution the defects due to design, manufacturing,
2009 ; +385 021 778 516 m Board type test installation and workmanship from the date of the
Email ID - Email performed on Provisional Acceptance Certificate (PAC) of the
:ljubomir.zubcic@koncareu.hr September 18 to first project (in case of contract award) and from
Website - Web: October 20-2017 in the date of first delivery in case of direct material
http://www.koncareu.hr CESI-IPH Berlin supply order shall be provided as confirmed by
Germany testing the manufacturer through their letter #Nil dated
laboratory Report # January 12, 2018.
06993-17-0659-1
Website -
http://www.atco.com.sa/en/manufactu
ring east west factory.asp
Website - http://www.hawaepbf.com
META SWITCHGEAR COMPANY Rating: The tests have been Previously MEMF-ETA Switchgear Manufacturing
Saudi Arabia ACDB 230/400 Vac, upto 3200 A, 75 conducted at CPRI, Company, Riyadh, Saudi Arabia [The name has
kA, 1 sec. India, witnessed by been changed based on S&SD letter #
P. O. Box 61891, Riyadh 11575, Saudi UL & SGS Engineers 14-02218-01-30504401 dated March 23, 2014].
Arabia,Near 2Nd New Industrial, 2Nd DCDB 800 A, 25 kA, 1sec. and certificates and
Phase Riyadh 11575, Saudi Arabia test reports are PQ Letter:
(Branch Of Memf Electrical Industries issued by UL. SGS S&SD letter # 14-02218-01-30504401 dated
Co.) inspection report March 23, 2014 & TS&SD letter
CHN/VCS/014/2014 #11-F03210/01-03032301 dated 29/11/2011
dated 24/01/2014 pre-qualified for AC&DC Panels.
for ACDB & DCDB
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by MEMF-ETA
Switchgear Manufacturing Company through
letter # META/11/13/AM, dated 21st Feb, 2011.
MUSAID SWITCHGEAR,
Saudi Arabia
SIEMENS
Saudi Arabia
Plant -Jeddah
Website - http://www.siemens.com.sa
CONDITION:
All type, special, routine and sample tests as per
SEC specifications/standards shall be carried out
on the first batch of each type of Auxiliary
AC&DC Panels to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory. All the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by
WESCOSA-Dammam through letter # Nil dated
18/05/2010.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by
WESCOSA-Dammam through letter # Nil dated
30/08/2010.
Riyadh
Total = 14
SUBSTATION PANELS
9. 3
TERMINAL BLOCKS Applicable Standards: 31-TMSS-06
PHOENIX
GERMANY
Website -
http://www.phoenixcontact.com/termin
al-blocks/26840.htm
WEIDMULLER
GERMANY
Website - http://www.weidmuller.com/
Cabur PQ Letter:
ITALY • Based on S&SD letter # 17-0071-030504401
dated January 09,2017, Cabur, Altare- Italy is
Plant -Altare- Italy pre-qualified for Terminal Blocks as conforming to
National Grid SA specification # 31-TMSS-06,
Contact Person - JAL International, Mr. with the following conditions:
Muhammad Sajjad Manzoor
Contact Person Email ID - WARRANTY:
sajjad.manzoor@jalinternational.com.sa • Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter No. NIL
dated 18/12/2015.
TE CONNECTIVITY - ENTRELEC
FRANCE - Previously ABB ENTRELEC
Lyon
Phoenix Contact GmbH & Co.KG Terminal Block (USST series, OTTA PQ Letter
INDIA series and RSC 5)
Based on S&SD letter S&SD letter
Plant -Haryana, India #MPQ8885399-Class IV(b)- 2020 _Class I(b).
dated September 12, 2022 is pre-qualified for
PHOENIX CONTACT Pvt. Ltd. Terminal Blocks as conforming to National Grid SA
Prithla – Dhatir Road specification # 31-TMSS-06, with the following
Village Dudhola, Palwal. P.O Baghola conditions:
Tehsil 2 District Palwal
Pin-121102 WARRANTY
Haryana-India
Ten (10) years extended warranty from the date
Haryana of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Contact Person - Mr. Ahmad Alewaidat, of direct material supply order), as confirmed,
Area Sales Manager through their Letter #PxC/ME/AE/21/00200, dated
Phone - +971 4 437 0324 May 4, 2021, shall be applicable for the
Email ID - equipment to be supplied to SEC/National Grid SA.
aalewaidat@phoenixcontact.com,
ddruehe@phoenixcontact.com,
alotsch@phoenixcontact.com
Website -
http://www.phoenixcontact.com
Phoenix Contact GmbH & Co.KG Terminal Block (USST series & OTTA PQ Letter
Poland series) Based on S&SD letter # MPQ8886399-Class IV(b)
-2020_Class I(b) dated December 23, 2021, the
Plant -Tomysl Poland manufacturer is prequalified for TERMINAL
BLOCKS as conforming to National Grid SA
PHOENIX CONTACT Wiel - Nowy specification #31-TMSS-06, with the following
Tomysl Poland conditions:
Tomysl WARRANTY
Ten (10) years extended warranty from the date
Contact Person - Ahmad Alewaidat, of PAC of the first turnkey project (in case of
Area Sales Manager contract award) or date of first delivery (in case
Phone - +971 4 437 0324 of direct material supply order), as confirmed,
Email ID - through their Letter #ST(11-18) dated November
aalewaidat@phoenixcontact.com, 07, 2018 shall be applicable for the equipment to
skhamistaim@phoenixcontact.com, be supplied to SEC/National Grid SA.
jzamudio@phoenixcontact.com
Contact Person Email ID -
aalewaidat@phoenixcontact.com,
skhamistaim@phoenixcontact.com,
jzamudio@phoenixcontact.com
Website -
https://www.phoenixcontact.com
Total = 10
SWITCHGEAR
10. 1
METAL – ENCLOSED AIR INSULATED SWITCHGEAR 11 KV THROUGH 34.5 KV Applicable Standards: 32-TMSS-01
EFACEC ENERGIA MAQUINAS E Bandariyah International 33kV Switchgear: 33kV SWGR: PQ letter:
EQUIPAMENTOS ELECTRICOS, S.A Co. Ltd, SWGR type: QBN7 & CB type DIVAC KEMA- Dielectric Based on S&SD letter # 17-07121/02-030504101
PORTUGAL CONTACT PERSON:Raid Incomer, Bus Section and Bus Riser tests, temperature dated October 24, 2017 EFACEC Portugal is
Shabsough or Rejith Rating; 2500A @ 40°C, 60Hz, rise test, Short time pre-qualified for 13.8kV Switchgear Type
Plant -Porto/Portugal Rami , 3rd Floor Building 25kAp(3s) / 65kAp, natural cooled - and Peak withstand NORMACEL & CB type DIVAC as conforming to
3 Mutlaq complex, P.O. Dimension (W-1300xD-2768xH-2858 current test, CB latest National Grid SA specification #
Parque Empresarial Da Arroteia 4296, Al Khobar-31952, mm). making & breaking 32-TMSS-01.
(Poente), Apartado 1018 4468-952 S. KSA Outgoing feeder (630 & 1250A) & test, Capacitor bank
Mameda De Infesta- Portugal Phone: 966-555010864 Capacitor feeder (1250A) @ 40°C, 60 switching current, PQ letter:
& Phone: Hz, 25kA(3s) / 65kAp- natural cooled. ES SC making Based on S&SD letter # 17-07122/02-030504101
Contact Person - Mr. Abílio Rodrigues: : 966-553712308 Dimension (W-1000xD-2768xH-2858 performance dated October 10, 2017, EFACEC Portugal is
+351 968331386;+351 229562300, Mr. rshabsough@bandariya mm) CESI: Temperature pre-qualified for 33KV Switchgear Type QBN7 &
Filipe Vila Real: +351 939236215; +351 h.com Or rise test, Arcing due CB type DIVAC as conforming to latest National
229562300 rrami@bandariyah.com Circuit Breaker: to internal fault, Grid SA specification # 32-TMSS-01
Email ID - Metal Clad Switchgears: : Incomer & Bus section: 2500A @ 40°C, EFACEC: Mechanical
abiliorodrigues@efacec.com; 60Hz, 25kAp(3s) / 65kAp, EFACEC, endurance test of
en@efacec.com & Power Portugal –Type CB DIVAC 3625G, CB & ES.
Transformers: Interrupter-(VG6), Opr. Mech: Spring
:filipe.vilareal@efacec.com; charged - CDV2M 13.8kV SWGR:
en@efacec.com Outgoing feeder: 630A @ 40°C, 60Hz, KEMA- Dielectric
Website - 25kAp(3s) / 65kAp; EFACEC, Portugal – tests, temperature
http://www.efacec.pt/en/switchgear/ Type CB DIVAC 3625B, Interrupter- rise test, Short time
& (VG6), Opr. Mech: Spring charged - and Peak withstand
http://www.efacec.pt/en/transformers/ CDV2M current test, CB
Outgoing feeder: 1250A @ 40°C, 60Hz, making & breaking
25kAp(3s) / 65kAp; EFACEC, Portugal – test, Capacitor bank
Type CB DIVAC 3625D, Interrupter- switching current,
(VG6), Opr. Mech: Spring charged - ES SC making
CDV2M performance
Capacitor feeder: 1250A@ 40°C, 60Hz, CESI: Temperature
25kAp(3s) / 65kAp; EFACEC, Portugal – rise test, Arcing due
Type CB DIVAC 3625D-K, Interrupter- to internal fault,
(VG6-K), Opr. Mech: Spring charged - EFACEC: Mechanical
CDV2M, Capacitor switching current: endurance test of
500A CB & ES.
Earthing switch: EFACEC, Portugal –
Type Qbn7, 25kA (3s)/65kAp.
CT: ALCE Turkey or ABB Czech
Republic lower side of CB of O/G & I/C,
Upper side CB for B/S & B/R .
VT: ALCE Turkey or ABB Czech
Republic
13.8kV Switchgear:
SWGR type: Normacel & CB type
DIVAC
Incomer, Bus Section and Bus Riser
Rating; 3150A @ 40°C, 60Hz,
25kAp(3s) / 65kAp, natural cooled &
3600A/ 4000A @ 40°C, 60Hz,
25kAp(3s) / 65kAp with forced
cooling- Dimensions; Incomer
(W-1000xD-1566xH-2619 mm), Bus
tie (W-1000xD-1666xH-2619 mm) &
Bus riser
(W-1000xD-1566/1666xH-2619 mm).
Outgoing feeder (630 & 1250A) &
Capacitor feeder (1250A) @ 40°C, 60
Hz, 25kA(3s) / 65kAp- natural cooled.
Dimension (W- 750xD-1566xH-2619
mm)
Circuit Breaker:
Incomer & Bus section: 3150@ 40°C,
60Hz, 25kAp(3s) / 65kAp, EFACEC,
Portugal –Type CB DIVAC 1725H,
Interrupter-(VG7), Opr. Mech: Spring
charged - CDV2M
Outgoing feeder: 630A @ 40°C, 60Hz,
25kAp(3s) / 65kAp; EFACEC, Portugal –
Type CB DIVAC 1725B , Interrupter-
(VG4-S), Opr. Mech: Spring charged –
CDV1M
Outgoing feeder: 1250A @ 40°C, 60Hz,
25kAp(3s) / 65kAp; EFACEC, Portugal –
Type CB DIVAC 1725D, Interrupter-
(VG4-S), Opr. Mech: Spring charged –
CDV1M
Capacitor feeder: 1250A@ 40°C, 60Hz,
25kAp(3s) / 65kAp; EFACEC, Portugal –
Type CB DIVAC 1725D-K, Interrupter-
(VG6), Opr. Mech: Spring charged -
CDV2M, Capacitor switching current:
630 A
SIEMENS Siemens Ltd. 13.8 kV AIS: Type/Model: NXAIR, Type Tests PQ letter:
TURKEY P.O. Box 4621, Jeddah 3600A conducted at IPH Based on S&SD letter # 17-04571-02-30504401
21412, K.SA. CESI-Berlin and dated June 22, 2017, SIEMENS -Turkey is
Plant -Turkey 02 661 8972 For Incomer: KEMA & PEHLA pre-qualified for 13.8KV Switchgear Type NXAIR
Aslam.jameel@siemens. 13.8kV, 3008A, @40 °C, 60Hz, as conforming to latest National Grid SA
Gebze Organize Sanayi Bolgesi, 1000. com 25kA(3s)/65kAp, AFLR with Natural specification # 32-TMSS-01, with the following
Cd. No. 1004, 41480-Gebze, Kocaeli, cooling, Dimensions (2500H X 1000W X conditions:
Turkey 2250D), CT Upper & Lower of CB
13.8kV, 3600A @40 °C, 60Hz, 25kA Warranty :
Gebze, Kocaeli (3s)/65kAp, AFLR with Forced cooling • Ten (10) years extended warranty/guarantee in
(4-fans), Dimensions (2500H X 1000W respect of defects due to design, manufacture,
Contact Person - Mr. Ediz Gizlier X 2250D), CT Upper & Lower of CB installation & workmanship from the date of
Phone - +90 (262) 676 2000 Circuit Breaker: 3AE1666-7, 13.8kV, Provisional Acceptance Certificate (PAC) of the
Email ID - ediz.gizlier@siemens.com 3150A, @40 °C, 60Hz , 25kA first turnkey project in case of contract award or
Contact Person Email ID - (3s)/65kAp, Vacuum Interrupter: date of delivery in case of direct material supply
ediz.gizlier@siemens.com VS17040, Opr. Mechanism: SION order, as confirmed in writing by the
Website - www.siemens.com.tr 3AE1666 manufacturer through their letter #
Earthing Switch: Siemens, Turkey, AEL-E/PQ/NXAIR/02/2013 dated July 25, 2014.
Type: 174-3138.3
CT & VT: ALCE, Turkey/Pfiffner, Turkey
For Bus Section:13.8kV, 3008A, @40 °
C, 60Hz, 25kA(3s)/65kAp, AFLR with
Natural cooling, Dimensions (2500H X
1000W X 2250D), CT Upper & Lower
of CB
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Forced cooling
(4-fans), Dimensions (2500H X 1000W
X 2250D), CT Upper & Lower of CB
Circuit Breaker: 3AE1666-7, 13.8kV,
3150A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VS17040, Opr. Mechanism: SION
3AE1666
CT & VT: ALCE, Turkey/Pfiffner, Turkey
For Bus Riser:
13.8kV, 3008A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300H X 1000W X
1750D)
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Natural
ABB ( T& D)
United States
Website - http://www.abb.us/
1, dt: 18-11-2021 TR
FORCED COOLED IAC 1250A
Rating: 2. CESI 200218,
13.8kV, 4000A @ 40°C, 60Hz, dt: 15-01-2022 TR
25kA(3s)/65kAp, IP4X, with FORCED IAC 3150A
COOLING, with CT upper & lower side 3. CESI
of CB. C1019437, dt: 12-11
-2021, TTR
Incomer (1000×2793x1880mm), DIELECTRIC LINEUP
VCB-LVB-17M-40D/301E2H, 4. CESI C1020284
Interrupter-10403 dt: 23-11-2021- TTR
DIELECTRIC BUS
Bus section (1000×2793x1880mm), EARTHING
VCB-LVB-17M-40D/301E2H, 5. CESI
Interrupter-10403 C1019677, dt: 12-11
-2021- TTR PARTIAL
• Bus riser (1000×2793x1880mm) DISCHARGE
6. CESI
C1019717, dt: 16-11
2. Type/Model - Alfa-12 -2021- TEMP RISE
3150/1250A
Rating: I/C, B/S, B/R-13.8kV, 3150A 7. CESI
(Natural cooled), 3600A (forced C1020459, dt: 18-11
cooled- fan in Incomer/BS/BR panels) -2021- TEMP RISE
@40°C, 60Hz, 25kV (3s), IP4X, AFLR, 3600A
25kA (1s) 8. CESI
C1020068, dated 19
Outgoing/ Consumer/capacitor feeders -11-2021- Short time
- 1250A @40°C, 60Hz, 25kV (3s), IP4X, peak withstand
AFLR, 25kA (1s) current
9. CESI C1020811
Incomer/Bus section/Bus Riser/Bus TTR STC Main Earth
metering Panels: 2500mm (H) X 31.5kA - Short time
1850mm (D) X 1000mm (W), CT on peak withstand
both side of CB for I/C & B/S current
Outgoing/ Consumer/capacitor feeders: 10. CESI
2500mm (H) X 1850mm (D) X 650mm C1019877, dt: 18-11
(W), CT on both side of CB. -2021 TTR 1250A
CB T10, T30, T60,
Circuit Breaker type: T100s(a,b), T100a,
Incomer/BS: VH-17H32D32 OP2
(Interrupter- LV8A)-LSIS/Korea – 11. KERI #
Incomer (CT upper & lower side of CB): Circuit breaker up to 24kV, 4000A, 40kA from
(1000x2200/2595x1400/1780mm), ABB-SACE-Italy (ITABB).
Bus Section
(1000x2200/2595x1400mm) &,
Bus riser (800x2200/2595x1400mm):
3003 @ 40°C, 60Hz, 25kA (3s)/65kAp.
1600A SWGR:
1600A Incomer
(800x2200/2595x1400mm) ; Bus
Section (800x2200/2595x1400mm, Bus
Riser (650x2200/2595x1400mm: 1607A
@ 40°C, 60Hz, 25kA(3s)/65kAp
CIRCUIT BREAKERS:
Incomer, Bus Section: VD4 17.31-25
(vacuum interrupter VG6), ABB Italy
(embedded pole)
FORCED COOLED
Rating:
TYPE/MODEL:
UniGear ZS1 13.8kV SWGR with CT
upper & lower side of CB.
Incomer (1000×2595x1780mm),
VCB-VD4 1731-25,Vacuum
Interrupter-VG6
OLD VERSION:
Rating: 13.8kV
OLD VERSION:
Type / Model: F400G
CIRCUIT BREAKER
SF1 & SF2
13.8kV SWGR:
Rating:
13.8kV, 2500A @ 55°C, 60Hz,
CIRCUIT BREAKERS:
2500 (3150A) Incomer, Bus Section:
LF3 -3150@ 40°C, 60Hz) Interrupter
SF6
FORCED COOLED
Rating:
13.8kV, 3600A @ 40°C, 60Hz,
25kA(3s)/65kAp, IP4X, FORCED
COOLED, CT lower side of CB.
SIEMENS
United States
Website -
http://www.usa.siemens.com/entry/en/
VA TECH
FRANCE
Plant -France
Website - http://www.vatech-hydro.at
WESCOSA
Saudi Arabia
Plant -Germany
Website -
http://www.alibaba.com/member/smilja
nmusic/contactinfo.html
Website - http://www.areva.com/
CIRCUIT BREAKERS:
Incomer, Bus Section: VD4 17.31-25
(vacuum interrupter VG6), ABB Italy
(embedded pole)
EARTHING SWITCH:
UMR, ELEKTROBUDOWA SA, Poland
LSIS METS Middle East Solution Power V17 & CB type LVB17 Type test were PQ Letter:
KOREA, Republic of Technical Services 13.8 kV successfully S&SD letter# 15-03781-2-30504401 dated June
Contact Person:Mr. conducted in KERI 04, 2015,for for MV Switchgear Type “ Solution
Plant -Republic Of Cheongju, Korea Abdul Majeed Atiyyah Incomer, Bus Section and Bus Riser Korea during 16th Power V17” & CB type “ LVB17” rated for 13.8
Vice President & Mr. ratings June to 17th July kV.
Ls Tower, 127 Ls-Ro Dongan-Gu Won Koo Kwon General (W-950xD-2000xH-2620 mm); 3000A 2014 in Presence of
Anyang-Si Syeonnggi-Do 431-848 Manager , P.O. Box: @ 40°C, 60Hz, 25kAp Approved IIA WARRANTY:
Korea 4323 Riyadh - 11491 (3s) / 65kAp, natural cooled. Inspector. Ten (10) years extended warranty/guarantee will
Kingdom of Saudi Arabia. Type Test Report be applicable for all 13.8 kV Medium Voltage
Contact Person - Mr Je Woo Lee Power Tel: +966 1 2424923,Fax: Outgoing feeder & Capacitor feeder #2014TC00634 Switchgear type Solution Power V17 to be
Grid Business Group & +966 1 2424924 (630 A / 1250A) - supplied to SEC/National Grid SA as confirmed
Mr.Kui-Joong,Yun General Manager PQ wkkwon@mets.com.sa , (W-750xD-2000xH-2620 mm); 1250A through LSIS Letter #013/LSIS-PQ/2015 dated
Dept Powr Grid Business Group aatiyyah@mets.com.sa @ 40°C, 60 Hz, 25kA 26th May 2015.
Phone - +82-2-2034-4541 , (3s) / 65kAp, natural cooled.
82-2-2034-4918 • Circuit Breaker:
Email ID - jwleea@lsis.com Incomer & Bus section: LSIS, Korea –
,kjoongy@lsis.com Type
(LVB-17M-40D/30-1E2H, Interrupter:
LV10403, Opr. Mech:
Motor-spring, LVB Pro-MEC)
Outgoing feeder: LSIS, Korea-Type
(LVB-17M-25D/12-1E2H,
Interrupter: LV10252, Opr. Mech:
Motor-spring, LVB Pro-MEC)
Capacitor feeder: LSIS, Korea-Type
(LVB-17M-25D/12-1E2H-DB,
Interrupter: LV12503, Opr. Mech:
Motor-spring, LVB Pro-MEC), Capacitor
Bank back to back
switching current-630A.
• Earthing switch Type SEH/MH31SM &
SEH/MH31M.
• CT: ABB, Czech (CT located in upper
& lower side of CB for
I/C, O/G, B/S).
• VT: ABB, Czech
KONCAR ELECTRICAL EQUIPMENT 33kV SWGR LIMITED TO DTA ONLY; FOR CTA
(KONCAR), SPLIT Type / Model: BVK-s-38 PREQUALIFICATION UNDER PROGRESS
CROATIA
Rating: 33kV,
Plant -Split/Croatia – Hrvatska
CIRCUIT BREAKER:
Koncar Elektricni Uredaji D.D Prisoje
29A, 21232 Dicmo Hr CT & VT:
Rating:
CIRCUIT BREAKER
S&C
United States
Website - http://www.sandc.com/
Website -
http://www.toshiba.co.jp/index j3.htm
HITACHI LTD 33kV SWGR: Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/Model: letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating:
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, 13.8kV
Tokyo, 101-8608, Japan
Type/Model:
Contact Person - Mr. Masaharu Tsumori
Phone - +81-3-4564-4741
Email ID -
masaharu.tsumori.gx@hitachi.com
Website - http://www.hitachi.com
Total = 21
SWITCHGEAR
10. 2
SF6 GAS INSULATED SWITCHGEAR 110kV to 132kV Applicable Standards: 32-TMSS-02
Hyundai Electric & Energy Systems Co. 145kV GIS 145kV GIS 145kV GIS
Ltd LATEST VERSION LATEST VERSION LATEST VERSION
SOUTH KOREA Type/Model: 145SP-3 Type/Model: Type/Model: 145SP-3
145SP-3
Plant -Ulsan Rating: 145kV, 2000A/3150A@40 ºC, PQ letter:
60HZ, 40kA (3s)/104kAp. Type Test performed Based on S&SD letter MPQ #11424110 dated
1000, Bangeojinsunhwan-doro, in KERI, Korea # October 01, 2018, Hyundai Electric & Energy
Dong-gu, Ulsan, South Korea, CB type: 145SP-K3, 145kV, 2018TC00434 Systems Co. Ltd., Korea is pre-qualified for 145
2000A/3150A@40 ºC, 60HZ, 40kA (2018), kV GIS type 145SP-3 as conforming to latest
Ulsan (3s)/104kAp, Operating mechanism: 2018TC00439 National Grid SA specification # 32-TMSS-02,
145M-MSCB(Spring charged) . (2018), with the following conditions:
Contact Person - Mr. Young Jun Bae CB Capability: Inductive load switching: 2018TC00441
(Regional General Manager) , Mr. Lee YES, Capacitor bank back to back (2018), WARRANTY:
Chung Hee (Vice President (Power Switching: YES. 2018TC00442 Ten (10) years extended warranty/guarantee
Infrastructure Sales & Marketing – II)) (2018), from the date of (PAC) of the Turnkey project (In
Phone - +966-11-293-2026, DS type: BDS type: 145SP-BD3 & LDS 2018TC00448 case of contract award) and from the date of
+82-31-8006-6837 type: 145SP-LD3 - 2000A/3150A@40 (2018), delivery for the direct material supply order. The
Contact Person Email ID - ºC, 60HZ, 40kA (3s) /104kAp, 2018TC00449 guarantee/warranty shall be applicable from first
peterbae@hyundai-electric.com , Operating mechanism: 145M-M3P. (2018), project and shall cover all the cost of materials
kolch@hyundai-electric.com 2018TC00450 and labor as per warranty/guarantee of materials
Website - MES type: 145SP-ME3, 40kA (3s) (2018), and workmanship and subsequently reduced
http://www.hyundai-elec.com /104kAp, Operating mechanism: 2018TC00455 yearly in case of future project award. This was
145M-M3P. (2018), confirmed in writing by Hyundai Electric & Energy
2018TC00456 Systems Co. Ltd., Korea through their letter #
HES type: 145SP-HE3, 40kA(3s) (2018), S370-1703-LSH1 dated # March 29, 2017.
/104kAp, Operating mechanism: 2018TC00458
145M-MSES (spring charged). (2018),
2018TC00459
(2018), NEW VERSION
145kV GIS 2018TC00510 Type/Model: 145SP-1
NEW VERSION (2018),
Type/ Model: 145SP-1 2018TC00511 PQ Letter:
(2018), TS&SD # 04-0692-030320, dated 15-03-2004,
Rating: 145KV, 2500A @40°C, 2017TC00070 pre-qualified GIS type 145SP-1
60Hz,40kA (3s)/ 104kAp (2017),
2016TC00558
CB type: 145SP-K1, Motor spring (2016), KEMA # Previously Hyundai Heavy Industries Co. Ltd [The
mechanism 2515-15 (2015). name has been changed based on P&SFD letter
#17-04234/01-030504401 dated May 24, 2017].
CB Capability:
Inductive load switching: YES
Capacitor bank back to back Switching:
NO
BDS type: 145SP-3PS1
LDS type: 145SP-3PS2
MES type: 145-3PS2
HES type: 145SP-LES2
OLD VERSION:
Type/ Model: 145SP
Rating: 145kV
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
DS type: 145SP-DS
MES: Type 145SP-ES
HES type: 145SP-LES
ILJIN ELECTRIC CO. LTD. META Switchgear GIS Type test completed Based on S&SD letter# 16-2020-01-030504401
SOUTH KOREA Company dated 31.03.2016 it is pre-qualified for 145kV GIS
(Branch of MEMF 145kV GIS type IJS1440-60, type IJS1440-60, 40kA(3s), 3150A as conforming
905-17, Mannyeon-ro, Hwaseong-si, Electrical Industries co) 40kA(3s), 3150A to National Grid SA specification # 32-TMSS-02,
Gyeonggi, KOREA 2nd New Industrial Area with the following conditions:
P.O. Box: 355988, CB type IJC1440-60, Opr. Mech: • Ten (10) years Extended Guarantee / Warranty
Contact Person - Mr. Jeong Kyung Woo Riyadh 11383 IJCM1440-60 (Motor Spring) from the date of PAC of first Project (in case of
, Mr. Jaeho Kim Kingdom of Saudi Arabia contract award) or from the date of delivery for
Phone - +82-2-707-9161 • CB Capability for: the direct material supply order. This was
Contact Person Email ID - Mr.Ahmed Elafifi Induced current switching: YES confirmed by the manufacturer through their
jkwoo@iljin.co.kr , jaeho.kim@iljin.co.kr +966536024245 Capacitor Bank back to back switching: Letter # ILJHK20160217W dated 17.02.2016
Website - http://www.iljinelectric.co.kr ahmed.elafifi@memf.com YES
.sa
Busbar DS type:IJBDE1440-60
(Opr. Mech: IJBDEM1440-60)
Hitachi Energy Ltd. Equipment designations & Ratings: Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia a) GIS: ELK-04C, 145kV, 3150A @40 and changed to Hitachi Energy Ltd.
ºC, 60HZ, 40kA (3s)/108kAp.
Plant -Dammam b) Circuit Breaker: SD04 Previous name was ABB , and changed to ABB
(2GHV010550M0001), 145kV, 3150A Contracting Co. Ltd based on S&SD letter
Dammam @40 ºC, 60HZ, 40kA (3s)/108kAp with #20-01681-30504401 dated October 01, 2020
spring charge operating mechanism
Contact Person - Abdulmajeed type: “MSD1 ((2GHV003600)”
Alothman CB Capability: Inductive: YES, Based on S&SD letter # 17-06695-01-30504401
Contact Person Email ID - Capacitor Bank: NO dated August 30, 2017, ABB - Al-Dammam, KSA
Abdulmajeed.alothman@hitachienergy. c) Busbar DS: TX04 is pre-qualified for 145 kV GIS Type ELK-04C as
com (2GHV010550M0001), 145kV, 3150A conforming to National Grid SA specification #
@40 ºC, 60HZ, 40kA (3s)/108kAp with 32-TMSS-02 rev.02, with the following
operating mechanism type “DHS conditions:
(1HC0070676)”.
d) Line DS: TX04
(2GHV010550M0001), 145kV, 3150A WARRANTY:
@40 ºC, 60HZ, 40kA (3s)/108kAp with Ten (10) years extended warranty from the date
operating mechanism type “DHS of PAC of the project (in case of contract award)
(1HC0070676)”. or date of delivery (in case of direct material
e) Maintenance ES: EM04 supply order), as confirmed to SEC/National Grid
(2GHV002340), 145kV, 60HZ, 40kA SA, through their Letter No # Nil, dated July 12,
(3s)/108kAp with operating mechanism 2017.
type “DHS (1HC0070676)”.
f) High Speed Earthing Switch: EB04
(2GHV006000), 145kV, 60HZ, 40kA
(3s)/108kAp with operating mechanism
type “EB04/2GHV006000)” Spring
charged.
g) CT: CN04 (2GHV010550M0001)
h) VT: PI04 (2GHV010550M0001)
i) Cable compartment : HK04F
(2GHV010550M0001), 2500A @40 ºC,
60HZ, 40kA (3s)/108kAp.
Hitachi Power Systems Indonesia Walid Jufalli Corporation GIS: CFTA-145, 145kV, 3150A @40 ºC, 145kV GIS Type PQ letter:
(HPSI) (WJCO) 60HZ, 40kA (1s)/104kAp. CFTA with CB, Based on S&SD letter # 17-03689-03-30504401
Indonesia P.O Box#1380, Jeddah DS/ES & cable dated May 18, 2017, it is pre-qualified for 145kV
21493, Kingdom of Saudi Circuit Breaker: compartment has GIS Type CFTA with CB CFPTB-40LB, FAR3 as
Plant -Indonesia Arabia. CFPTB-120-40LB-FAR3, 145kV, 3150A successfully conforming to National Grid SA with specification
Mr. Yuichi Wakabayashi, @40 ºC, 60HZ, 40kA (1s)/104kAp with completed the type # 32-TMSS-02 with the following conditions:
EJIP Industrial Park Plot 8E, Cikarang +966 (12) 2637600 & spring charge operating mechanism tests in laboratories;
Selatan, Bekasi, 17750 Indonesia +966 500338276 type: “FA”. KERI – Korea during WARRANTY:
yuichi.wakabayashi@hit 25 July to 10 August •Ten (10) years extended Guarantee/warranty
Contact Person - Mr. Hendrawan, achi-td.com Busbar DS: CFL-EEA, 145kV, 3150A 2016 & Hitachi from the date of PAC of the project (in case of
Phone - Phone: +62-21-8970350, @40 ºC, 60HZ, 40kA (1s)/104kAp with Laboratory- Japan contract award) or date of delivery (in case of
Mobile: +62 815 11536388 operating mechanism type “CA”. during 14 November direct material supply order), as confirmed to
Email ID - to 17 December SEC/National Grid SA, through their Letter No #
hendrawan@hitachipowersystems.co.i Line DS: CFL-EEA, 145kV, 3150A @40 2016 HPSI-BD/02/VIII/2014 R3 dated March 22, 2017.
d& ºC, 60HZ, 40kA (1s)/104kAp with
yoshikazu.hirotani@hitachipowersyste operating mechanism type “CA”.
ms.co.id
Contact Person Email ID - Mr. MS: CFL-EEA, 145kV, 60HZ, 40kA
Hendrawan, (1s)/104kAp with operating mechanism
Website - type “CA”.
http://www.hitachi.com/products/powe
r/TandD/location/index.html HSES: CFGM-FA, 145kV, 60HZ, 40kA
(1s)/104kAp with operating mechanism
type “MSG” Spring charged.
GE GRID GMBH GIS Type test completed Based on S&SD letter# 13-4433-01-30504401,
SWITZERLAND 145kV GIS type F35 with dated 16 January 2013, it is pre-qualified for
rated current, 3150A @40°C, 60Hz, 145kV GIS type F35 with rated current, 3150A
Plant -. @40°C, 60Hz, against specification #
CB type- F35-CB4 / Opr. 32-TMSS-02, Rev.1 with the following condition:
Oberentfelden Switzerland Mech: FK3-2 (spring charged),
CB Capability for: 1. Eight (8) years extended warranty from the
Inductive load switching: YES date of PAC of the first turnkey project (in case
of contract award) or from the date of first
Capacitor bank back to back Switching: delivery of direct material supply order. This was
YES confirmed through manufacturer lletter ref:
Q1F35_210409 dated 21 April 2009.
Line & Busbar DS-F35-DES-4/
Opr. Mech: ME1-3, Old Version:
145kV GIS type B65 with CB type B65-
MES-F35-DES-4/ Opr. Mech: ME1-3, Previously " Areva T &D AG,
SWITZERLAND-Oberentfelden ", the name has
HES-F35-EFZ/Opr. Mech:MF-3 (spring been changed to ALSTOM Grid AG,
charged), Oberentfelden, Switzerland, based on ALSTOM
Grid Letter # Nil dated July 11, 2012.
CT-F35-CT4, Previously " ALSTOM Grid AG Switzerland,
Oberentfelden ", the name has been changed to "
OLD GE Grid Switzerland GmbH,Oberentfelden ".
based on GE Grid letter # Nil dated June 01, 2016.
145kV GIS type B65
DS type B65-DS
ES type B65-ES
ABB AG NEW VERSION (TYPE ELK-04C ) NEW VERSION NEW VERSION (TYPE ELK-04C )
GERMANY Equipment designations & Ratings: (TYPE ELK-04C ) PQ letter:
a) GIS: ELK-04C, 145kV, 3150A @40 ABB, AG Germany Based on S&SD letter # 18-01225-2-30504401
Mannheim, Germany , Brown Boveri ºC, 60HZ, 40kA (3s)/108kAp. has successfully dated April 01, 2018, for ABB, AG Germany is
Street 30, 63457 Hannau, Germany completed type tests pre-qualified for 145 kV GIS Type ELK-04C as
b) Circuit Breaker: SD04 on 145kV GIS Type conforming to latest National Grid SA
Contact Person - Mr. Josef Hanson (2GHV010550M0001), 145kV, 3150A ELK-04C at specification # 32-TMSS-02, with the following
Email ID - josef.hanson@de.abb.com @40 ºC, 60HZ, 40kA (3s)/108kAp with Independent testing condition:
Website - http:// spring charge operating mechanism laboratories KEMA –
http://www.abb.de/cawp/deabb200/ea type: “MSD1 ((2GHV003600)” Netherland & PEHLA WARRANTY:
b4f33d72c264bec1256fb90037eeaa.as CB Capability: Inductive: YES, – Switzerland Ten (10) years extended warranty from the date
px Capacitor Bank: NO of PAC of the project (in case of contract award)
or date of delivery (in case of direct material
c) Busbar DS: TX04 supply order), as confirmed to SEC/National Grid
(2GHV010550M0001), 145kV, 3150A SA, through their Letter No #
@40 ºC, 60HZ, 40kA (3s)/108kAp with PGHV-180115/GIS-1, dated March 02, 2018.
operating mechanism type “DHS
(1HC0070676)”.
OLD VERSION (TYPE ELK-04 )
d) Line DS: TX04 PQ Letter: TS&SD letter # 11-00455-5-03032301
(2GHV010550M0001), 145kV, 3150A dated April 04, 2011, for new version 145kV GIS
@40 ºC, 60HZ, 40kA (3s)/108kAp with type ELK-04.
operating mechanism type “DHS
(1HC0070676)”. WARRANTY
Ten (10) years extended warranty/guarantee in
e) Maintenance ES: EM04 respect of defects due to design, manufacture,
(2GHV002340), 145kV, 60HZ, 40kA installation & workmanship from the date of
(3s)/108kAp with operating mechanism Provisional Acceptance Certificate (PAC) of the
type “DHS (1HC0070676)”. first turnkey project in case of contract award or
date of first delivery in case of direct material
f) High Speed Earthing Switch: EB04 supply order , as confirmed by the manufacturer
(2GHV006000), 145kV, 60HZ, 40kA through letter no. PTPH/GVS-Nb, 10, dt: 14th May
(3s)/108kAp with operating mechanism 2010.
type “EB04/2GHV006000)” Spring
charged. OLD VERSION
PQ Letter: DM # 011/63000/KB/168, dated
g) CT: CN04 (2GHV010550M0001) 18-08-1422 (H) prequalified GIS type ELK-04
CB Capability:
Inductive load switching: YES
Capacitor bank back to back Switching:
YES
DS type: ELK-DE0-3POS,
OLD VERSION:
Type/ Model: ELK-04
HYOSUNG HEAVY INDUSTRIES 145 kV GIS Type test was LATEST VERSION:
CORPORATION (HICO) LATEST VERSION conducted at Based on S&SD letter # 15-07077-01-30504401
SOUTH KOREA Type HSG-144D independent testing dated September 07, 2015, it is pre-qualified for
40kA, 2500A/ 3150 A labs like CESI- 145kV GIS Type
Plant -Republic of Changwon, Korea Italy,KERI – Korea, HSG-144D, 40 kA, 2500A/3150A
CB type HCSP-144D/ MELCO-Japan,
Eric Rhie, 450, Gongdeok-Dong, Opr. Mechanism HMSP-500 (spring HYOSUNG For latest WARRANTY
Mapo-Gu, Seoul , Korea charged); version Ten (10) years Extended Guarantee / Warranty
Tel:82-707-6180 from the date of PAC of the Project (in case of
CB Capability for: contract award) or from the date of delivery for
Contact Person - Mr. Jason Kang; Sale Inductive current switching: YES the direct material supply order. This is applicable
Manager & Mr. Young Kim; Sales Capacitor bank back to back switching: from first project and subsequently reduced
Manager YES yearly in case of future project. This was
Contact Person Email ID - confirmed, through their Letter No.SB/TDS/AK/
Jason.kang@hyosung.com , Busbar DS type 120 930/2100A dated 01/04/2013.
yw.kim@hyosung.com HDMO-144D/ Opr. Mech: HM3P-710;
Website - Line DS type
http://www.hyosung.co.kr/eng/index.js HDMO-144C / Opr. Mech. HM3P-710;
p?, www.hyosung.com MES type HEMO-144C
/ Opr. Mech. HM3P-710; HES type
HEMS-144C / Opr. Mech.
HMMS-500 (Spring charged), Cable
compartment
type-HSG-144D
• Old version:
145kV GIS type HEXABOLIC-TH7
CB type
DTH7 Hydraulic mechanism
ES type ST TH7.
DS type 8DN8
ES type 8DN8.
KONCAR HIGH VOLTAGE 145kV GIS GIS & ADAPTORS ONLY TO DTA.
SWITCHGEAR INC, Type/ Model: K8D.6
CROATIA PQ Letter: As per existing
Rating: 132kV
Plant -Zagreb/Croatia-Hrvatska
CB Capability:
Borongajska Cesta 81C 10000 Zagreb Inductive load switching: NO
Capacitor bank back to back Switching:
Contact Person - Mr. Toni Delić NO
Phone - +385 (0)99 2475 663, +385
(0)1 235 4606
Email ID - toni.delic@koncar-eva.hr
Website - http://www.koncareu.hr
CT: JK
NEW VERSION
Type/Model: 8DN8-II
Rating: 145kV
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
Rating: 145kV
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
DS type: 8DN8
ES type: 8DN8
FUJI ELECTRIC CO. 145kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
OLD VERSION letter # XAE-VR-121213, dated 13-12-2012 and
Type/ Model: SDA5 (SDA514), 145kV FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
TOSHIBA CORPORATION, T&D 145kV GIS Type Tested at ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN Toshiba lab during DURING APRIL 2005.
NEW VERSION 25th March to 12th 2005.
Website - April 204 & 18th to
http://www.toshiba.co.jp/index j3.htm GIS Type 20th Aug 2014 and NEW VERSION
G3A-b with CB type GSPK-145FPW / repeated internal arc
Opr. Mechanism tests in KEMA PQ Lettter
GSPK-145FW (spring charged); Netherland during Based on S&SD letter # 15-09018-2-30504401
CB Capability for: 8th to 10th April dated November 10, 2015, it is pre-qualified for
Inductive current switching: YES 2015 & 10th to 12th 145kV GIS Type
Capacitor bank back to back switching: June 2015. G3A-b, as conforming to National Grid SA
YES Report Nos. specification # 32-TMSS-02,
2238-15,30-07,29-0
Busbar DS type DAM-145W2 / 7,27-07, WARRANTY
Opr. Mech: DAM; Line DS type Ten (10) years Extended Guarantee / Warranty
DBM-145W2 / Opr. Mech. DBM; from the date of PAC of first Project (in case of
MES type EBM-145W2 / Opr. Mech. contract award) or from the date of first delivery
EBM; for the direct material supply order. This was
HES type confirmed, through their Letter No. TSB/TDS/AK/
EAP-145W2 / Opr. Mech. EAP (Spring 120930/2100A dated 01/04/2013.
charged)
OLD VERSION
Type/ Model:
Rating: 145kV
CB type: GSPK-145AP
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
HITACHI LTD 145kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN NEW VERSION: subsequent change affected as per HITACHI
Type/ Model: CFTA letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating: 145kV,
Akihabara Daibiru Building, 18-13, NEW VERSION:
Soto-Kanda 1-Chome, Chiyoda-Ku, CB type: CFPT-120-40L, FAR3 Motor PQ Letter:
Tokyo, 101-8608, Japan spring mechanism MD # 011/63000/KB/169, dated 18-08-1422 (H),
pre-qualified GIS type CFTA.
Contact Person - Mr. Masaharu Tsumori CB Capability:
Phone - +81-3-4564-4741 Inductive load switching: NO
Email ID - Capacitor bank back to back Switching:
masaharu.tsumori.gx@hitachi.com NO
Website - http://www.hitachi.com
DS type: CFL-120
ES type: CFL-120
OLD VERSION
Type/ Model: CFT
Rating: 145kV
DS type: SFL-EA
MITSUBISHI ELECTRIC CORPORATION Yuji KOBAYASHI / 145kV GIS Type Test performed PQ letter:
JAPAN General Manager LATEST VERSION in Based on S&SD letter #18-03818-030504401
Power Transmission & Type/Model: 100-GMKD-1 KERI, Korea # dated October 30, 2018, Mitsubishi Electric,
Plant -T&D Systems Center, Amagasaki Distribution Division, Rating 145kV, 3150A@40 ºC, 2017TC00557, dated Japan is pre-qualified for 145 kV GIS type
City, Japan MITSUBISHI ELECTRIC 60Hz,40kA (3s)/ 104kAp 15-17/03/2017, 100-GMKD-1 as conforming to latest National Grid
SAUDI, LTD. P.O. box: CB type: 120-SFMT-40CJ, 145kV, KERI, Korea # SA specification # 32-TMSS-02, with the
Mitsubishi Electric Corporation, Tdsc, 2391, Riyadh 11451 3150A@40 ºC, 60HZ, 40kA 2017TC00559, dated following conditions:
Marketing Department, 8-1-1 +966 11 477 7947 (3s)/104kAp. Operating mechanism: 08-09/03/2017,
Tsukaguchi-Honmachi, Amagasaki City, (Ext.260) / +966 55 547 BM-J4 (spring motor charged) KERI, Korea # WARRANTY:
Hyogo, 661-8661, Japan 5316 CB Capability: 2017TC00085, dated Ten (10) years extended warranty/guarantee
Kobayashi.Yuji@fc.mels Inductive load switching: YES 20/03-16 to from the date of (PAC) of the Turnkey project (In
Contact Person - Mr. Yohei Okada a.com.sa Capacitor bank back to back Switching: 26-07-17, case of contract award) and from the date of
Phone - +81-6-6497-8288 YES KERI, Korea # delivery for the direct material supply order. The
Email ID - BDS /LDS type: 120-GRD, 3150A@40 2017TC00468, dated guarantee/warranty shall be applicable from first
Okada.Yohei@dw.MitsubishiElectric.co. ºC, 60HZ, 40kA (3s) /104kAp, 21-03-2017, project and shall cover all the cost of materials
jp Operating mechanism: MDE and labor as per warranty/guarantee of materials
Website - MES type: 120GRED, 40kA (3s) KEMA, Netherland # and workmanship and subsequently reduced
http://global.mitsubishielectric.com/ /104kAp , Operating mechanism: MDE 2049-18, dated 1-23 yearly in case of future project award. This was
HES type: 120-GRE-A, 40kA(3s) Feb to 09-14 March confirmed in writing by Mitsubishi Electric, Japan
/104kAp Operating mechanism: MBE 2018, through their letter # Nil dated July 08, 2018.
(spring motor charged) KEMA, Netherland #
Cable compartment: H60F392, 2050-18, dated 28
3150A@40 ºC, 60HZ, 40kA (3s) Feb to 02 March
/104kAp 2018, -ORIGINALLY TMT&D CORP. & DISSOLVED
KEMA, Netherland # DURING APRIL 2005.
2051-18, dated 1-23
145kV GIS Feb to 09-05 March
NEW VERSION 2018,
Type/Model: 100GMKD
Mitsubishi, Japan #
Rating 145kV, 60Hz,40kA (xs)/ 104kAp HKT-29504, dated
CB type: 120-SFMT-40CJ 23-24/01/2017,
CB Capability: Mitsubishi, Japan #
Inductive load switching: YES HKT-29474, dated
Capacitor bank back to back Switching: 10/11/2017,
NO Mitsubishi, Japan #
DS type: 120GRD/GLD HKT-29530, dated
MES type: 120GRED/GRE 04-08/08/2017,
HES type: 120 GRED/GRE-A Mitsubishi, Japan #
HKT-29472, dated
OLD VERSION: 26-30/09/2016,
Type/Model: 120GMKM Mitsubishi, Japan #
HKT-29475, dated
Rating: 145kV 15-30/09/2016,
CB type: 120-SFMT-40, Pneumatic Mitsubishi, Japan #
mechanism HKT-29470, dated
DS type 120-GR-20, 120-GL-20 24/08-13/09/2016,
MES type: 120-GRE, 120-GREC Mitsubishi, Japan #
HES type: 120-GREA HKT-29478, dated
07-08/11/2016,
OLD VERSION: Mitsubishi, Japan #
Type/ Model: 100GMKD HKT-28699, dated
Nil,
Rating:145kV, Mitsubishi, Japan #
CB type: 120-SFMT-40CE, Motor spring HKT29397, dated
mechanism 13-01-2015,
DS type: 120GLD Mitsubishi, Japan #
HES type: 120-GREA HKT29398, dated
13-01-2015,
Mitsubishi, Japan #
HKT29397, dated
13-01-2015,
Mitsubishi, Japan #
HKT-28699-A, dated
13-01-2015,
Mitsubishi, Japan #
HKT-29346, dated
08-06-2013,
Mitsubishi, Japan #
HKT-29365, dated
5-08- 2013,
Mitsubishi, japan #
HKT-29510-A, dated
20-24 June, 2013
Total = 15
SWITCHGEAR
10. 3
SF6 GAS INSULATED SWITCHGEAR 230 KV Applicable Standards: 32-TMSS-02
GE Grid Solution SAS (GE & Alstom 245kV GIS Previously ALSTOM GRID SAS, FRANCE, the
Joint Venture) name has been changed to GE Grid Solutions /
FRANCE Type/Model: B105 GE & ALSTOM joint Venture - Francebased GE
Grid Solutions / GE & ALSTOM joint Venture letter
Plant -Aix-Les Bains, France Rating: 245kV # Nil, dated October 13, 2016.
Hitachi Energy Switzerland Ltd. 245kV GIS Mfr. Name change from ABB Switzerland Ltd to
SWITZERLAND NEW VERSION Hitachi Energy Switzerland AB
Type / Model: ELK-14/300
Toto Building, Brown Boveri Strasse 5 1HC0071250M0040) PQ Letter:
8050, Zurich, Switzerland S&SD letter # 14-00064-30504101 dated January
Rating: 245kV, 4000A, 40°C, @ 60Hz, 26, 2014 and ABB Letter # PPHV-300GIS CH-05
Contact Person - MR. Dieter 63kA(1s)/163.8kAp dated February 02, 2014 the designation has
Fuechsle(Global Qualification and been corrected.
Certification Manager for GIS.), Mr. CB Type: ELK-SP14/300
Abdulmajeed Alothman (1HC0071250M0040) / Opr. Mech: CONDITION:
Email ID - HMB4 (1HC0071250M0040) Capacitor Bank Back to Back switching type test
dieter.fuechsle@hitachienergy.com, will be performed when required in the project,
abdulmajeed.alothman@hitachienergy.c confirmed by ABB letter # PPHV-140120/GIS-1,
om dated 21-01-2014.
Contact Person Email ID - CB Capability:
dieter.fuechsle@hitachienergy.com, Inductive load switching: xx
abdulmajeed.alothman@hitachienergy.c Capacitor bank back to back Switching:
om No
Website - www.hitachienergy.com
LDS & BDS Type: ELK-TK14/300
(1HC0071250M0040) / Opr. Mech: BAC
(1HC0071250M0040)
CT Type: ELK-CN14/300
(1HC0071250M0040)
OLD VERSION
Type/ Model: ELK-1
Rating: 245kV
CB Type: ELK SP2-1.
FUJI ELECTRIC CO. 245kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/Model: letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
CB:
CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
xx
Website -
http://www.toshiba.co.jp/index j3.htm
HITACHI LTD 245kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type / Model: MFPT MFPTB-300-63L letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating: 245kV
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB type: MFPTB-300-63LA,
Tokyo, 101-8608, Japan HAR/MFTB-300-563L
MITSUBISHI ELECTRIC CORPORATION 245kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Type / Model: 200GPS
Plant -T&D Systems Center, Amagasaki
City, Japan Rating: 245kV
Total = 8
SWITCHGEAR
10. 4
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR, 380 KV Applicable Standards: 32-TMSS-02
2007TC00603/09-04
DS: BDS type 550DRM2/2016, LDS -2007, KEMA #
type-550 DRM1/2016, 4000A@55 ºC, 56-07/ 23 Feb-4 May Old version:
60HZ, 63kA (3s) /163.8kAp, Operating 2007. PQ Letter:
mechanism: MMF-4 (for both DS). TS&SD Letter # 08-01807-03032301, Dated 16
July, 2008 for 380kV GIS.
MES: 550ERM/2016, 63kA (3s)
/163.8kAp , Operating mechanism: CONDITION:
MMF-5. Back to back capacitor switching test for C.B.
shall be done in independent laboratory in the
HSES: 550 LES/2016, 63kA(3s) presence of SEC Engineers whenever there is a
/163.8kAp Operating mechanism: requirement for this test in the PTS of forthcoming
MSF-4 (spring charged). SEC projects.
CB Capability:
Inductive load switching: xx YES
Capacitor bank back to back
Switching:xx NO
ES-550 ERM
HES-550 LES
GE Grid Solution SAS (GE & Alstom GIS Type test completed Previously "AREVA T&D– FRANCE-(AIX-LES
Joint Venture) 420kV GIS type T155 FOR NEW TYPE: GE BAINS) ", the name has been changed to
FRANCE CB type T155, FB2T (Hydraulic Mech.) Grid Solution SAS ALSTOM Grid SAS-France based on ALSTOM
(GE & Alstom Joint Grid-France letter # Nil, dated December 07,
Plant -Aix-Les Bains, France FOR NEW TYPE: Venture) – France 2012, and again the name has been changed to
GIS: T155-420kV (Mono), 3150A @ 40° has successfully GE Grid Solution SAS (GE & Alstom Joint
GE Grid Solution SAS (GE & Alstom C , 60Hz , 63kA(1Sec) completed type tests Venture) -France based on their letter # Nil, dated
Joint Venture), 1, Rue Paul Doumer Circuit breaker: T155-CB3, 3150A@40° on 420kV GIS Type October 13, 2016.
73100 Aix-Les-Bains (France) C, 60HZ, 63kA (1s), T155- 420KV
Operating mechanism:FK3-6 (Mono) at FOR NEW TYPE:
Aix-Les Bains BDS/LDS: T155-DS3, 3150A@40°C, Independent testing PQ letter:
60HZ, 63kA (1s), laboratories; CREDA Based on S&SD letter # 18-01638-01-30504401
Contact Person - Mr. Zinedine RABAH Operating mechanism: ME2-2 or ME4 - France, KEMA – dated April 17, 2018, for GE Grid Solution SAS
Phone - +33(0) 4 79 88 79 80 + 971 4 MES: T155-ES3, Netherland & CESI – (GE & Alstom Joint Venture) – France is
4299 651 Operating mechanism: ME2-2 or ME4 Italy. pre-qualified for GIS Type T155- 420kV (Mono)
HES: T155-EF3, Operating mechanism: as conforming to latest National Grid SA
ME2-2 (spring charged) or ME4 ME4 DS/ES Opr. specification # 32-TMSS-02.
Cable compartment: T155, , Mechanism Type
3150A@40°C, 60HZ tests: CERDA # WARRANTY:
Current transformer: T155-CT3 8143-2, dated Ten (10) years extended warranty/guarantee
Bus duct: T155-420kV: 3150A@55°C, 09/06/2015, CERDA from the date of Provisional Acceptance
60HZ, 63kA (1s) # 8143-3, dated Certificate (PAC) of the first turnkey project in
09/06/2015, GE # case of contract award or date of first delivery in
2019-069, dated case of direct material supply order, as
18/10/2019, RUAG # confirmed to SEC/National Grid SA, through their
Hybrid GIS: 7169, dated letter # BHT14032017, dated March 14, 2017.
420kV GIS type T155 Mono with its 24/01/2014.
components up to current rating
3150A, @55 ͦC, 60Hz PQ letter (ME4):
Hybrid GIS: Based on S&SD letter # 19-01461-01-30504401
Type test completed dated November 26, 2019, ME4 Operating
for Hybrid GIS as Mechanism for 420kV DS/MES/HES is accepted
indicated in GIS Type for GE Grid Solution SAS (GE & Alstom Joint
T155 Mono. Venture) – France for the pre-qualified GIS Type
T155- 420kV (Mono).
For SF6-Air
Bushing; CERDA #
10113_1/17-22/06/2 WARRANTY (ME4 Opr. Mech.):
020 & Ten (10) years extended warranty/guarantee
10114/02-11-2020, from the date of (PAC) of the Turnkey project (In
GE # case of contract award) and from the date of
TS0792/22-12-2020, delivery for the direct material supply order. The
WARRANTY
Hitachi Energy Ltd. Type of GIS: ELK-3/420 Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia (1HC0071250M0070) and changed to Hitachi Energy Ltd.
CT: CN3(1HC0071250M0070)
VT: PI3(1HC0071250M0070)
Cable box: HK3(1HC0071250M0070)
SF6 to Air Bushing:
HD3(1HC0071250M0070)
SF6-oil termination:
HT3(1HC0071250M0070)
Surge Arrester:
AZ3(1HC0071250M0070)
Hitachi Energy Switzerland Ltd. 420kV GIS Mfr. Name change from ABB Switzerland Ltd to
SWITZERLAND Type/ Model: ELK-3/420 Hitachi Energy Switzerland AB
(1HC0071250M0070)
Toto Building, Brown Boveri Strasse 5 PQ letter:
8050, Zurich, Switzerland Rating: 420kV, 4000A @40°C, 60Hz, S&SD letter # 13-00748-30504101 dated
63kA(1s)/164kAp November 06, 2013, 420kV GIS type ELK-3/420
Contact Person - MR. Dieter (1HC0071250M0070) @ 4000A, 60Hz.
Fuechsle(Global Qualification and CB: ELK-SP3/420 (double break),
Certification Manager for GIS.), Mr. PQ letter:
Abdulmajeed Alothman Operating Mechanism-HMB8 (Hydraulic Based on S&SD letter #17-5541-1-30504401
Email ID - spring charged) dated July 27, 2017, ABB Switzerland is
dieter.fuechsle@hitachienergy.com, permitted to use Single Break Circuit Breaker
abdulmajeed.alothman@hitachienergy.c CB Capability: Type SP3-1 (1HC0071250M0080) in the already
om Inductive load switching: Yes Prequalified 380kV GIS Type ELK-3/420 in
Contact Person Email ID - Capacitor bank back to back Switching: addition to the Double Break Circuit Breaker Type
dieter.fuechsle@hitachienergy.com, Yes SP3 (1HC0071250M0070) as conforming National
abdulmajeed.alothman@hitachienergy.c Grid SA with specification # 32-TMSS-02 Rev.02
om CB: ELK- SP3-1 (1HC0071250M0080) with the following conditions:
Website - www.hitachienergy.com (Single break), Warranty :
•Ten (10) years extended warranty/guarantee in
Rating: 420kV, 5000A @40°C, 60Hz, respect of defects due to design, manufacture,
63kA(3s)/164kAp, installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Operating Mechanism-HMB-4.3 first turnkey project in case of contract award or
(Hydraulic spring) date of delivery in case of direct material supply
order, as confirmed in writing by the
CB Capability: manufacturer through their letter #
Inductive load switching: YES PGHV-160826/GIS-1 dated August 26, 2017.
Capacitor bank back to back switching:
YES HYBRID GIS:
PQ Letter:
Line & Busbar DS: ELK-TK3/420, S&SD letter # 14-03182-01-30504401, dated
Operating Mechanism-ELK-BAC 29-01-2015, Pre-qualified ABB, Switzerland GIS
type ELK-3/420 (1HC0071250M0070) with its
MES: ELK-TK3/420, components are acceptable for Hybrid GIS upto
Operating Mechanism-ELK-BAC current rating @ 3150A, 55°C, 60Hz.
CT : ELK-CN3
Rating: 420kV
CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
xx
DS: 8QD1
TOSHIBA CORPORATION, T&D 420kV GIS: On HOLD based on VP, Engineering letter #
JAPAN 19-00222-30504401 dated January 24, 2019.
NEW VERSION:
Website - TOSHIBA CORPORATION, T&D JAPAN-
http://www.toshiba.co.jp/index j3.htm Type/ Model: GID ORIGINALLY TMT&D CORP. & DISSOLVED
DURING APRIL 2005.
Rating: 420kV, 3150A @40°C, 60Hz,
63kA(3s)/164kAp PQ Letter:
S&SD letter # 14-05807-2-30504401, dated
CB: GSRK-420CHK (Single break) with September 08, 2014, it is pre-qualified for 420 kV
internal grading capacitor 860pF, GIS type GID.
Operating Mechanism: Hydraulic
GSRK-420CHK
WARRANTY:
CB Capability: Ten (10) years extended warranty/guarantee in
Inductive load switching: YES respect of defects due to design, manufacture,
Capacitor bank back to back Switching: installation & workmanship from the date of
YES Provisional Acceptance Certificate (PAC) of the
Busbar & Line DS: DTM, Operating first turnkey project in case of contract award or
Mechanism DTM (motor) date of delivery in case of direct material supply
order and subsequently reduced yearly in case
MES: EBM, Operating Mechanism EBM of future project award., as confirmed by the
(motor) manufacturer through their letter # TSB/TDS
/AK/130206/2145-R1 dated August 12, 2014
HES: EYP, Operating Mechanism EAP
(motor spring charged)
OLD VERSION:
Type/ Model: GID CB type GSR
400R2B/GSRK, DOUBLE BREAK,
Hydraulic mechanism
Rating: 420kV
HITACHI LTD 420kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/ Model: IFT letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
Rating: 420kV, 3150A @40°C, 60Hz
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB: Double break
Tokyo, 101-8608, Japan
CB Capability:
Contact Person - Mr. Masaharu Tsumori Inductive load switching:xx
Phone - +81-3-4564-4741 Capacitor bank back to back
Email ID - Switching:xx
masaharu.tsumori.gx@hitachi.com
Website - http://www.hitachi.com
MITSUBISHI ELECTRIC CORPORATION 420kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Type/ Model: 400-GPS
Plant -T&D Systems Center, Amagasaki
City, Japan Rating: 420kV, 4000A @40°C, 60Hz,
63kA(1s)/164kAp
Mitsubishi Electric Corporation, Tdsc,
Marketing Department, 8-1-1 CB:
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan CB Capability:
Inductive load switching: xx
Contact Person - Mr. Yohei Okada Capacitor bank back to back Switching:
Phone - +81-6-6497-8288 xx
Email ID -
Okada.Yohei@dw.MitsubishiElectric.co.
jp
Website -
http://global.mitsubishielectric.com/
Total = 12
SWITCHGEAR
10. 5
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR, 550 KV Applicable Standards: 32-TMSS-02
GIS
GE Grid Solution SAS (GE & Alstom GIS: T155-550kV, 550kV, 63kA Type Tests were PQ letter:
Joint Venture) (1s)/163.8kAp, 3150A, 40ºC, 60Hz performed in Based on S&SD letter # 18-00209/01-30504101
FRANCE CERDA, France, dated July 11, 2018, GE Grid solutions SAS -
Circuit Breaker: T155-CB2, 550kV, KEMA, Netherland France is pre-qualified for 550kV GIS as
Plant -Aix-Les Bains, France 63kA (1s)/ 163.8kAp, 3150A, 40ºC, and CESI, Italy conforming to latest National Grid SA
60Hz with operating mechanism: specification # 32-TMSS-02, with the following
GE Grid Solution SAS (GE & Alstom T155-CI2 (Hydraulic), Capacitor bank conditions:
Joint Venture), 1, Rue Paul Doumer back to back switching: 1000A (C2),
73100 Aix-Les-Bains (France) Inductive current switching: 315A WARRANTY:
Ten (10) years Guarantee/Warranty in respect of
Aix-Les Bains Busbar Disconnector: T155-DS, 550kV, defects due to design, manufacture, installation &
63kA (1s)/ 163.8kAp, 3150A, 40ºC, workmanship from the date of Provisional
Contact Person - Mr. Zinedine RABAH 60Hz, Operating Mechanism: T155-ME Acceptance Certificate (PAC) of the project in
Phone - +33(0) 4 79 88 79 80 + 971 4 case of contract award and from the date of
4299 651 Line side Disconnector: T155-DS, delivery in case of direct material supply order,
550kV, 63kA (1s)/ 163.8kAp, 3150A, as confirmed by the manufacturer vide letter #
40ºC, 60Hz, Operating Mechanism: Nil, dated August 18, 2015
T155-ME
Hitachi Energy Switzerland Ltd. 550kV GIS Type test completed Mfr. Name change from ABB Switzerland Ltd to
SWITZERLAND Hitachi Energy Switzerland AB
Type/ Model: ELK-3/550
Toto Building, Brown Boveri Strasse 5 (1HC0071250M0100) 550kV GIS
8050, Zurich, Switzerland
Rating: 550kV, @ 4000A, 40 º C, 60Hz PQ Letter
Contact Person - MR. Dieter S&SD letters 14-00741-30504101dated
Fuechsle(Global Qualification and CB: ELK-SP3/550 (1HC0071250M0100) December 08, 2014 & 14-00043-30504101, dated
Certification Manager for GIS.), Mr. (double break), Operating January 20, 2015, pre-qualified for 550 kV GIS
Abdulmajeed Alothman Mechanism-HMB8 type ELK3/550(1HC0071250M0100).
Email ID - (1HC0071250M0100)
dieter.fuechsle@hitachienergy.com, WARRANTY:
abdulmajeed.alothman@hitachienergy.c CB Capability: Ten (10) years extended warranty/guarantee in
om Inductive load switching: Yes respect of defects due to design, manufacture,
Contact Person Email ID - Capacitor bank back to back Switching: installation & workmanship from the date of
dieter.fuechsle@hitachienergy.com, Yes (1000A) Provisional Acceptance Certificate (PAC) of the
abdulmajeed.alothman@hitachienergy.c first turnkey project in case of contract award or
om Busbar DS: ELK- date of delivery in case of direct material supply
Website - www.hitachienergy.com TE3/550(1HC0071250M0100), order and subsequently reduced yearly in case
Operating of future project and shall be applicable for all
Mechanism-DH(1HC0071250M0100) Substations to be supplied to SEC/National Grid
SA as confirmed through ABB, Switzerland Letter
Line DS: # PPHV-550kV dated 02-05-2014.
ELK-TV3/550(1HC0071250M0100),
Operating
Mechanism-DH(1HC0071250M0100)
MES:
ELK-EM3/550(1HC0071250M0100),
Operating
Mechanism-DH(1HC0071250M0100)
HES:
ELK-EB3/550(1HC0071250M0100),
Operating
Mechanism-DB(1HC0071250M0100)
Cable compartment:
ELK-HK3/550(1HC0071250M0100)
HYBRID GIS:
Based on S&SD letter #16-02585-02-30504401
dated April 10, 2016, pre-qualified Hyosung,
Korea 550kV GIS type 550 HSG has pre-qualified
for Hybrid GIS with following conditions:
• Ten (10) years extended warranty from the
date of PAC of the turnkey project in case of
contract award and date of delivery in case of
direct material supply order. This is applicable
from first project and subsequently reduced
yearly in case of future project. This was
confirmed by the manufacturer through letter #
HG-NG-HGIS-160221-550 dated February
21,2016
CONDITION:
As per 550kV GIS type 8DQ1
WARRANTY:
As per 550kV GIS type 8DQ1
Total = 4
SWITCHGEAR
10. 6
METAL CLAD GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR (11KV,13.8KV.33KV OR Applicable Standards: 32-TMSS-03
34.5KV)
SIEMENS 33kV GIS PQ Letter:
GERMANY S&SD letter # 15-0186-01-30504401, dated
Type/ Model: 8DA10 January 22, 2015 and TS&SD Letter #
Berlin, Germany 10-02461-02-03032301, dated August 31, 2010,
IC SG EA MF Rating: 36kV, 2500A @40°C, 60Hz, the manufacturer is prequalified for 36kV GAS
Wernerwerkdamm 5, 25kA(3s)/65kAp Insulated Medium Voltage SWGR Type 8DA10.
13629, Berlin, Germany
CB: 3AH49 with vacuum interrupter CONDITION:
Phone - +49 (911) 433 8321 type VSG 40040, rated current up to
Website - 2500A, 40°C, 60Hz WARRANTY:
www.siemens.com/ingenuityforlife Seven (7) years extended warranty/guarantee in
CB: 3AH49 with vacuum interrupter respect of defects due to design, manufacture,
type VS 30040 (40kA), rated current installation & workmanship from the date of
up to 2375A 40°C, 60Hz Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
CB: 3AH49 with vacuum interrupter date of delivery in case of direct material supply
type VS 30040 (40kA), rated current order, as confirmed by Siemens trough letter #
up to 2375A 40°C, 60Hz 8DA10_PQR_R1 dated 24/08/2010
CB Capability:
Capacitor bank back to back Switching:
400A with CB type 3AH49, interrupter
VSG40040
Total = 1
SWITCHGEAR
10. 7
SF6 Non-Extensible Ring Main Unit, 11 KV through 34.5 KV Applicable Standards: 32-TMSS-07
Saudi Arabia
Website -
http://www.driescher.de/home/index.ht
m
Website -
http://www.schneider-electric.fr/
Website -
http://w1.siemens.com/entry/cc/en/
Website -
http://www.lucyswitchgear.com/T
Plant -France
Website - http://www.areva.com/
Total = 9
SWITCHGEAR
10. 8
LOAD BREAK SWITCHES UPTO 34.5kV Applicable Standards:
Saudi Arabia
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
AREVA
FRANCE
FRITZ DRIESCHER
GERMANY
HITACHI
JAPAN
Total = 7
SWITCHGEAR
10. 9
Gas Insulated transmission Lines (GIL) for rated voltage 110kV and above Applicable Standards: 32-TMSS-05
Hyundai Electric & Energy Systems Co. Model: 550SR/2016 Type tests PQ Letter
Ltd successfully
SOUTH KOREA Ratings: 420kV / 60Hz /4000A@55˚C completed at KERI– Based on S&SD letter # MPQ466720410 dated
/63kA (3s)/163.8kAp South Korea; August 20, 2020, the manufacturer is prequalified
Plant -Ulsan Reports KERI # for Gas Insulated Transmission Lines (GIL) for
20TC100133, dated rated voltage 420KV, as confirming to National
1000, Bangeojinsunhwan-doro, 01 April-2020, KERI Grid SA specification # 32-TMSS-05, with the
Dong-gu, Ulsan, South Korea, # 20TB100037, following conditions:
dated 30 March
Ulsan 2020 & KERI # WARRANTY
20TB100037, dated
Contact Person - Mr. Young Jun Bae 30 March 2020. Ten (10) years extended warranty from the date
(Regional General Manager) , Mr. Lee of PAC of the first turnkey project (in case of
Chung Hee (Vice President (Power contract award) or date of first delivery (in case
Infrastructure Sales & Marketing – II)) of direct material supply order), as confirmed,
Phone - +966-11-293-2026, through their Letter No. S370-20191111-WL1
+82-31-8006-6837 dated November 11, 2019 shall be applicable for
Contact Person Email ID - the equipment to be supplied to SEC/National Grid
peterbae@hyundai-electric.com , SA.
kolch@hyundai-electric.com
Website -
http://www.hyundai-elec.com
GE Grid Solution SAS (GE & Alstom Type: T155 Type Tests were PQ Letter
Joint Venture) Ratings: 420kV / 60Hz /3150A@55˚ successfully Based on S&SD letter # 21-00341-30504401
FRANCE C/63kA (3s)/163.8kAp completed at dated March 25, 2021, GE GRID SOLUTION
CREDA/France SAS/France is prequalified for Gas Insulated
Plant -Aix-Les Bains, France Report # 8158, dt: transmission Lines (GIL/GIB), 420kV, Type: T155,
28-05-2015, 7859-2, as confirming to National Grid SA specification #
GE Grid Solution SAS (GE & Alstom dt: 06-09-2013, 32-TMSS-05, with the following conditions:
Joint Venture), 1, Rue Paul Doumer 6791, dated
73100 Aix-Les-Bains (France) 30-03-2010 & 8858, WARRANTY
dated 30-08-2016, Ten (10) years extended warranty from the date
Aix-Les Bains CESI, Milan Report # of PAC of the first turnkey project (in case of
B5024295-2, dated contract award) or date of first delivery (in case
Contact Person - Mr. Zinedine RABAH 19/20-11-2015 & of direct material supply order), as confirmed,
Phone - +33(0) 4 79 88 79 80 + 971 4 8734-2, dated through their Letter No. SEC_GIB_warranty dated
4299 651 15-01/2016, January 06, 2021 shall be applicable for the
ALSTOM Report # equipment to be supplied to SEC/National Grid SA.
TS0296, dt.
10-03-2014 &
TS0198, dated
01/2012 and
VOLTA/France
Report #
201404522_001,
dated 05-06-02014
respectively.
Hitachi Energy Ltd. ELK-3/420 (1HC0071250M0070), Type Tests were Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia 420kV, 63kA(1s)/170kAp, 4000A @ 40 performed on July and changed to Hitachi Energy Ltd.
°C and 3150A @ 55°C, 60Hz along with 2017 at PEHLA
Plant -Dammam the following components: Testing Laboratory Previous name was ABB , and changed to ABB
i. VP3 – Parallel Compensator Baden, Switzerland Contracting Co. Ltd based on S&SD letter
Dammam ii. VQ3 – Lateral Dismantling Unit and following are #20-01681-30504401 dated October 01, 2020
iii. VQL3 – Lateral Dismantling Unit the type test
Contact Person - Abdulmajeed with Axial Compensation reports:
Alothman iv. VG3 & VI3 – Connecting Bus PQ Letter:
Contact Person Email ID - v. VL3, VT3 & VX3 – Connecting 17072Ba_HASH651 Based on S&SD letter # 17-07181-2-30504401
Abdulmajeed.alothman@hitachienergy. Piece 061 dated November 13, 2017, ABB, Dammam - KSA
com vi. VW3 – Angle Piece 17073Ba_HASH670 is pre-qualified as production factory for GIL &
vii. HD3 (1HC0071250M0070)– SF6 555 ABB s.r.o-PPHV, Czech Republic as feeder
Insulated Bushing with Porcelain 17074Ba_HASH641 factory as conforming to National Grid SA
Insulator 659 specification # 32-TMSS-05, with the following
viii. HK3 (1HC0071250M0070)– Cable 17070Ba_HASH660 conditions:
end Termination 877
ix. HT3 (1HC0071250M0070)– WARRANTY:
Transformer Direct Connection Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # Nil, dated September 18, 2016.
HYOSUNG HEAVY INDUSTRIES Type: HSG 426A 1 Type Tests were PQ Letter:
CORPORATION (HICO) successfully Based on S&SD letter # 20-00923-30504401
SOUTH KOREA Ratings: 420kV / 60Hz /4000A@55˚C completed at KERI, dated March 30, 2020, the manufacturer is
/63kA (3s)/163.8kAp South Korea - prequalified for 420 KV Gas Insulated
Plant -Republic of Changwon, Korea Report Transmission Lines (GIL) as confirming to
#19TB101032-R2 & National Grid SA specification # 32-TMSS-05,
Eric Rhie, 450, Gongdeok-Dong, Report with the following conditions:
Mapo-Gu, Seoul , Korea #20TC100023-R1,
Tel:82-707-6180 dated 04.12.2019 WARRANTY:
and 29.01.2020 Ten (10) years extended warranty from the date
Contact Person - Mr. Jason Kang; Sale Respectively. of PAC of the first turnkey project (in case of
Manager & Mr. Young Kim; Sales contract award) or date of first delivery (in case
Manager of direct material supply order), as confirmed,
Contact Person Email ID - through their Letter #HS-SEC-420GIL-200306-01
Jason.kang@hyosung.com , dated March 06, 2020, shall be applicable for the
yw.kim@hyosung.com equipment to be supplied to SEC/National Grid SA.
Website -
http://www.hyosung.co.kr/eng/index.js
p?, www.hyosung.com
Total = 5
Website - http://www.jaeps.com/eng/
SIEMENS ,GERMANY
GERMANY
Germany
Website -
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx
Website -
http://www.toshiba.co.jp/index j3.htm
TRIDELTA MEIDENSHA GMBH Previously " TRIDELTA ", the name has been
GERMANY changed to TRIDELTA Meidensha GmbH -
Germany, based on TRIDELTA Meidensha GmbH
Website - http://www.tridelta.de/ Letter #Nil dated August 10, 2016.
Hitachi Energy Switzerland Ltd Hitachi Energy Type/Model: Change name from ABB HV TECHNOLOGIES
SWITZERLAND Hitachi Energy Ltd. SWITZERLAND to Hitachi Energy Switzerland
Riyadh, Saudi Arabia Rating: 420kV
Plant -Jurastrasse 45,Ch-5430 Phone: +966 11 2181703
Wettingen, Switzerlandaddress: Doser, Mobile: +966 500414555 Type/Model:
Jurastrasse 45, Ch-5430 Wettingen, abdulmajeed.alothman@
Switzerland hitachienergy.com Type/Model:
TE ENERGY / TYCO ELECTRONIC MDAE4-120 Class 4 up to 132 kV Type tested in CESI PQ Lettter
United Kingdom Lab Italy in the Based on S&SD letter # 15-09503-01-030504401,
presence of TE Witham Uk is prequalified for Surge Arrester
Plant -Witham Uk (Plant) SEC/National Grid type MDAE4-120 Class 4 up to 132 kV.
SA engineers & SGS
Bowthorpe Emp Stevenson Road Inspector on 7th to WARRANTY:
Brighton East Sussex Bn2 0Df 19th April 20414 Ten (10) years Guarantee / warranty for the in
.Seal Leak Test on respect of defects due to design, manufacture,
Contact Person - Mr. Oday M. Hindi conducted in TYCO installation & workmanship from the date of
Transmission Support Manager,Mr. Electronics test Provisional Acceptance Certificate (PAC) of the
Graeme Currie, Product Manager Laboratory (Whitam, first turnkey project in case of contract award or
Phone - +44-0-1273-692591 UK) in the presence date of delivery in case of direct material supply
Email ID - Oday.hindi@te.com, of SGS Inspector order, as confirmed by the manufacturer thru
Graeme.currie@te.com and CESI letter #nil, dt: Sep 14, 2011.
representative on
15th to 16th Sep
2015.
Report, General
report No.
TE-MDAE4-120
HUBBELL POWER SYSTEMS, INC. Previously OHIO BRASS [The name has been
United States changed based on S&SD/P&SFD letter#
14-07802-30504401 dated October 22, 2014 and
Plant -Columbia , United States based on Hubbell Power System Grid Letter # Nil
dated October 06, 2014]
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
Total = 14
CIRCUIT BREAKERS
12. 1
CIRCUIT BREAKER, SF6, DEAD TANK, 69 KV Applicable Standards: 37-TMSS-01
Hitachi Energy USA Inc. Hitachi Energy Mfr. Name change from ABB T&D to Hitachi
United States Hitachi Energy Ltd. Energy USA Inc
Riyadh, Saudi Arabia
Plant -United Stated Phone: +966 11 2181703
Mobile: +966 500414555
100 Distribution Circle, Moint Pleasant abdulmajeed.alothman@
PA 15666 USA hitachienergy.com
Website -
http://www.toshiba.co.jp/index j3.htm
Georgia
Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m
Total = 8
CIRCUIT BREAKERS
12. 2
CIRCUIT BREAKER, SF6, DEAD TANK, ,110 - 132 KV Applicable Standards: 37-TMSS-01
Hitachi Energy USA Inc. Hitachi Energy Mfr. Name change from ABB T&D to Hitachi
United States Hitachi Energy Ltd. Energy USA Inc
Riyadh, Saudi Arabia
Plant -United Stated Phone: +966 11 2181703
Mobile: +966 500414555
100 Distribution Circle, Moint Pleasant abdulmajeed.alothman@
PA 15666 USA hitachienergy.com
ABB
SWITZERLAND
Website -
http://www.toshiba.co.jp/index j3.htm
MITSUBISHI ELECTRIC CORPORATION Type / Model: 120-SFMT-40E ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 145kV, 40kA 2000A
Plant -T&D Systems Center, Amagasaki
City, Japan
ALSTOM Grid LLC Type / Model: DT1-145FK SUSPENDED for all SEC/National Grid SA ongoing
United States and forthcoming projects based on VP,
Rating: 132kV, 2000A, 40kA Engineering letter # 13-01705-30504401 dated
Charleroi, United States March 23, 2013.
PQ Letter:
TS&SD letter # 10-02708-02-03032301 dated
25/10/2010, it is pre-qualified for 145kV Dead
Tank Circuit Breaker type DT1-145FK, 40KA,
2000A.
CONDITION:
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter as confirmed by the manufacturer thru
letter #nil, dt: 6th Mar, 2009.
Georgia
Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m
Total = 10
CIRCUIT BREAKERS
12. 3
CIRCUIT BREAKER, SF6, DEAD TANK, 230 KV Applicable Standards: 37-TMSS-01
Hitachi Energy USA Inc. Hitachi Energy Mfr. Name change from ABB T&D to Hitachi
United States Hitachi Energy Ltd. Energy USA Inc
Riyadh, Saudi Arabia
Plant -United Stated Phone: +966 11 2181703
Mobile: +966 500414555
100 Distribution Circle, Moint Pleasant abdulmajeed.alothman@
PA 15666 USA hitachienergy.com
ALSTOM Grid LLC Type / Model: DT1-245 F3 SUSPENDED for all SEC/National Grid SA ongoing
United States and forthcoming projects based on VP,
Rating: 230kV, 2500A, 60Hz Engineering letter # 13-01705-30504401 dated
Plant -Charleroi , United States March 23, 2013.
PQ Letter:
Type DT1-245 F3
CONDITION:
Di-electric test, riv test, continuous current
temperature rise test @ 2500 A, 60Hz is to be
carried out in the first batch in the presence of 3
SEC engineers and 1 IIA inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Website -
http://www.toshiba.co.jp/index j3.htm
MITSUBISHI ELECTRIC CORPORATION Type / Model: 200-SFMT-40E ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 245 kV, 40kA, 3150 A
Plant -T&D Systems Center, Amagasaki
City, Japan
Georgia
Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m
Total = 7
CIRCUIT BREAKERS
12. 4
CIRCUIT BREAKER, SF6, LIVE TANK, 69 KV Applicable Standards: 37-TMSS-02
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden
ABB
SWITZERLAND
SIEMENS, GERMANY
GERMANY
AREVA
SWITZERLAND
Website - http://www.areva.com/
AREVA
FRANCE
Website - http://www.areva.com/
Total = 5
CIRCUIT BREAKERS
12. 5
CIRCUIT BREAKER, SF6, LIVE TANK, 110 - 132 KV Applicable Standards: 37-TMSS-02
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
SIEMENS, GERMANY
GERMANY
AREVA
FRANCE
Website - http://www.areva.com/
AREVA
GERMANY
Website - http://www.areva.com/
Total = 4
CIRCUIT BREAKERS
12. 6
CIRCUIT BREAKER, SF6, LIVE TANK, 230 KV Applicable Standards: 37-TMSS-02
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
SIEMENS, GERMANY
GERMANY
AREVA
FRANCE
Website - http://www.areva.com/
Total = 3
Website -
http://www.electricityforum.com/produ
cts/htg.htm
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Total = 2
ABB HV TECHNOLOGIES
Swaziland
Total = 1
Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.
Plant -2Nd Industrial Area,Riyadh, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Contact Person - Mr. Essam
Bashraheel & Mr. Ahmed Abubasha
Phone - Tel:+966-011-476-2644 PQ Letter
Fax:+966-011-476-9622 Based on S&SD Letter No. 16-06734-30504401
Contact Person Email ID - dated 31 Aug 2016. It is Prequalified for
Essam.bashraheel@hitachienergy.com Integration (Assembly) & Testing of
& SCADA/RTU560 Equipment from Original
Ahmed.Abubasha@hitachienergy.com Equipment Manufacturer (OEM) type tested and
approved by SEC/National Grid SA Specification
38-TMSS-03 Rev.01 with the following Conditions
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/SCA/08022016/ 2016, dt: 06/11/2016.
EFACEC SISTEMAS DE ELCTRONICA, Bandariyah International Type/Model - CLP500 Institue Electro PQ Lettter
S.A Co. Ltd Tecnico Portugues Based on TS&SD letter# 09-01819-03032301
PORTUGAL 3rd Fllor, Building 3 Portugal, Labecm dated 23rd June 2009, it is prequalified for for
Mutlaq Office comple Al Laboratoriao De. RTU type CLP500 as confirming to SEC
Plant -Maia/Portugal Khobar KSA compatibbilidate specification # 38-TMSS-03, rev.0 with the
Phone - 0553712308 electromagnet ica. following condition:
Rua Eng Frederico Ulrich, Ap 3078 Email - Test Date - jan 2010,
,4471-907 Maia Portugal Maia , Portugal rrami@bandariyah.com July 2010 WARRANTY
Test Report No. - Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Ricardo Cunha, E-2009-1004.02 , respect of defects due to design, manufacture,
Mr. André Cruz 09-12-119-022a installation & workmanship from the date of
Phone - +351 932025959; +351 Provisional Acceptance Certificate (PAC) of the
229402000; +351 939333313 first turnkey project in case of contract award or
Email ID - ricardo.cunha@efacec.com; date of delivery in case of direct material supply
en@efacec.com; acruz@efacec.com. order.
Website -
http://www.efacec.pt/en/automation/
FOXBORO
AUSTRALIA
Website - http://www.foxboro.com/
GE HARRIS ON HOLD
CANADA
Website - http://www.harris.com/
SAT
AUSTRIA
Website -
http://w1.siemens.com/entry/cc/en/
VA TECH
AUSTRIA
LSIS , PQ Lettter
SOUTH KOREA Based on TS&SD letter# 08-00492/1--03032301
dated 24th March, 2008, it is prequalified for for
Ls Tower, 127, Ls-Ro, Dongan-Gu, RTU, SOE and associated transducers with the
Anyang-Si, Gyeonggi-Do, following condition
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
Total = 14
Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.
Plant -2Nd Industrial Area,Riyadh, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Contact Person - Mr. Essam
Bashraheel & Mr. Ahmed Abubasha
Phone - Tel:+966-011-476-2644 PQ Letter
Fax:+966-011-476-9622 Based on S&SD Letter No.
Contact Person Email ID - 16-06734-30504401dated 31 Aug 2016. It is
Essam.bashraheel@hitachienergy.com Prequalified for Integration (Assembly) & Testing
& of SCADA/RTU560 Equipment from Original
Ahmed.Abubasha@hitachienergy.com Equipment Manufacturer (OEM) type tested and
approved by SEC/National Grid SA Specification
38-TMSS-03 Rev.01 with the following
Conditions
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/SCA/08022016/ 2016, dt: 06/11/2016.
GE HARRIS ON HOLD
CANADA
LSIS , WARRANTY
SOUTH KOREA Seven (7) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Ls Tower, 127, Ls-Ro, Dongan-Gu, installation & workmanship from the date of
Anyang-Si, Gyeonggi-Do, Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Mr. Je-woo, Lee date of delivery in case of direct material supply
Assistant Manager order.
Phone - +82-2-2034-4541
Email ID - jwleea@lsis.com
Website - http://www.lsis.com
Website - http://www.ronan.com/
Total = 7
United States
Website -
http://www.ametekpower.com/
NEXANS
SWITZERLAND
PAN ALARM
United States
RONAN ENGINEERING
United Kingdom
Website - http://www.ronan.com/
STEINER
JAPAN
Website -
http://www.steiner-binoculars.com/ind
ex.html
Website - http://www.abb.fi/
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
Website - http://www.ffcpg.com.my/
SIEMENS
GERMANY
LS PREVIOUSLY LG
SOUTH KOREA
Website - http://www.lscable.com/
Total = 12
AMETEK (ROCHESTER) SAUDI ARABIAN Multifunction Recorders TR-2200, Type Tests PQ Letter
United States INDUSTRIAL & TRADING 57-120V RMS, 1A or 5A RMS performed at RETLIF Based on S&SD letter#18-04456-030504401.
CO. LTD. (SAIT) Test Lab, New York, dated January 06, 2019, the manufacturer is
Plant -ROCHESTER, NY 00-966-13-8344122 USA , February prequalified for Dynamic System Monitoring
yasin@saite.com.sa , 28-March 2, 2018 Equipments as confirming to SEC specification #
255 North Union Street Pcd-dam@saite.com.sa with Retest on 38-TMSS-06, Rev.0, with the following
Rochester, N.Y. 14605 Failed Bump Test on conditions:
United States March 5-8, 2018
ROCHESTER, NY WARRANTY
Ten (10) years extended warranty in respect of
Contact Person - Sal Cardella- Product the defects due to design, manufacturing,
Marketing Manager, Steve Bleier - installation and workmanship from the date of the
Director of Marketing and Business Provisional Acceptance Certificate (PAC) of the
Development first project (in case of contract award) and from
Phone - 001-585-263-7700 the date of first delivery in case of direct material
Email ID - power.sales@ametek.com supply order shall be provided as confirmed by
Contact Person Email ID - the manufacturer through their letter #Nil dated
sal.cardella@ametek.com , January 06, 2016.
steve.bleier@ametek.com
Website - www.ametekpower.com
KoCos Messtechnik Germany Mohammed Al-Ojaimi SHERLOG CRX •Fault Record PQ letter:
GERMANY Contracting Est. System Report # Based on S&SD letter # 17-06723-030504401
KoCoS Messtechnik AG (E170309E1) by dated October 31, 2017, KoCos Messtechnik
Plant -Korbach, Germany Suedring 42 Phoenix TestLab – Germany is pre-qualified for Dynamic System
D-34497 Korbach, Germany Monitor (DSM) as conforming to latest National
KoCoS Messtechnik AG Germany •DFR & DSM Report Grid SA specification # 38-TMSS-06
Suedring 42 Tel. +49 5631 9596-0 # (U170309E1) by
D-34497 Korbach, Germany info@kocos.com Phoenix TestLab – WARRANTY:
Germany Ten (10) years extended warranty/guarantee in
Korbach •Functional Test respect of defects due to design, manufacture,
Report # Nill by installation and workmanship from the date of
Contact Person - KoCos Germany KoCos Messtechnik Provisional Acceptance Certificate (PAC) of the
(Lea-Sophie Kotthoff, Sales), Local - Germany first turnkey project in case of contract award or
Agent- Mohammed Al-Ojaimi date of first delivery in case of direct material
Contracting Est. (Abbad S. Ahmed, supply order, as confirmed by the manufacturer
Manager Energy Services.) vide letter # Nil, dated October 08, 2015.
Phone - Tel. +49 5631 9596-0
Email ID - info@kocos.com
Contact Person Email ID -
lkotthoff@kocos.com
abbad.ahmed@alojaimi.com
Website - www.kocos.com
DIGSILENT GMBH
GERMANY
Website - http://www.digsilent.de/
Website -
http://www.powertechnology.com/
Total = 6
POWER DIAGNOSTIX SYSTEMS GMBH PDM PEHLA # 16005Ba, Based on S&SD letter # 16-05170/01-30504401
GERMANY dated 17-02-2016, dated June 23, 2016, it is prequalified for Partial
Type PDMAR 120S, PDMAR56S, PD system dated Discharge Monitoring System without UHF
Plant -. PDMCR 12-02-2016, PD Sensors as conforming to National Grid SA
system dated Material Specification 38-TMSS-07 with the
Vaalser Strasse 250, D-52064 16-02-2016, following condition:
Aachen Germany TUV Rheinland #
21248037-002, •Ten (10) years extended warranty from the date
Contact Person - Mr. Markus Soller dated of PAC of the turnkey project in case of contract
Contact Person Email ID - 19-23-02-2016, award and date of delivery in case of direct
support@pdix.com soller@pdix.com TUV Rheinland # material supply order, as confirmed by the
Website - WWW.pdix.com 21248033_003, manufacturer through letter # Nil dated
dated 31-03-2014.
23-24-02-2016,
EMC Test NRW #
P12-Z-00353-002,
dated 25-02-2016,
KERI #
2014TS02444, dated
18-09-2014
ABB Power Equipment (Xiamen) ABB Electrical Industries UHF Partial Discharge Sensor Type ABB, China has PQ letter:
Company Limited, Zhangzhou Branch. Co. Ltd. WB14 rated for 145kV successfully Based on S&SD letter # 18-00461-2-30504401
CHINA P.O. Box 8796 Riyadh completed type tests dated February 25, 2018, ABB Power Equipment
11492 – Kingdom of on 1 Partial (Xiamen) Company Limited, Zhangzhou Branch -
Plant -China Saudi Arabia discharge Sensors China is pre-qualified for UHF Partial Discharge
+966 11 2653030 Type WB14 rated for Sensor Type WB14 rated for 145kV as
Wenpu Industrial Park, Taiwanese essam.bashraheel@sa.a 145kV at conforming to latest National Grid SA
Investment Zone, bb.com Independent testing specification # 38-TMSS-07
Zhangzhou, Fujian, P.R.China Postal laboratory PEHLA –
code: 363107 Germany during 09 WARRANTY:
to 12 May 2016. • Ten (10) years extended warranty/guarantee in
Zhangzhou respect of defects due to design, manufacture,
installation and workmanship from the date of
Contact Person - Ms. Jocelyn-Lihua Provisional Acceptance Certificate (PAC) of the
Ying first turnkey project in case of contract award or
Phone - +86 (0)596 5022001 , +86 date of first delivery in case of direct material
(0)18150892388 supply order, as confirmed by the manufacturer
Email ID - Jocelyn-Lihua Ying vide letter # Nil, dated January 23, 2018.
@cn.abb.com
Contact Person Email ID - Jocelyn-Lihua
Ying @cn.abb.com
TYPE TEST:
Type/special & routine tests shall be conducted
on OPDMS Type APM 5000 in presence of three
SEC/National Grid SA Engineers and third party
inspector in independent accredited laboratory
for the first projects or first purchase order at the
sole expenses of the manufacturer as confirmed
through their letter# 141018-APM-KSA dated
14/10/2018.
TECHIMP Mejdaf Group External UHF sensor: “045HRH30” Type Test PQ letter:
ITALY Riyadh Data acquisition unit: “PD Hub 12 CH” Conducted during Based on S&SD letter # 18-01963-30504401
Hossam Elkady, Senior Control unit: “Rack 42U” November 2016 and dated May 09, 2018, TECHIMP– Italy is
Plant -Bologna Technical Sales Engineer January/February pre-qualified for On-line Partial Discharge
+966 (0) 583549862 & 2017 in independent Monitoring System as conforming to latest
VIA Toscana, 11c, 40069 Zola Predosa, 4109912 Ext: 119 laboratories namely National Grid SA specification # 38-TMSS-07,
Bologna, h.elkady@mejdaf.com CREI Ven S.c.a.r.l, with the following conditions:
Italy & SIQ Ljubljan,
Contact Person - Stephan Heberer Slovenia WARRANTY:
Phone - +3905119986050 Ten (10) years extended warranty/guarantee in
Email ID - sales@techimp.com CERI Ven S.c.ar.l , respect of defects due to design, manufacture,
Contact Person Email ID - Italy # 170516LP, installation & workmanship from the date of
Stephan.heberer@ altanova-group.com dated 27-02-2017, Provisional Acceptance Certificate (PAC) of the
Website - www.techimp.com CERI Ven S.c.ar.l , first turnkey project in case of contract award or
Italy # 163402LP, date of delivery in case of direct material supply
dated 02-12-2016 order, as confirmed by TECHIMP – Italy through
SIQ Ljubljan, their letter # Nil dated February 24, 2013.
Slovenia #
T211-0003/17, dated
06-01-2017,
SIQ Ljubljan,
Slovenia #
T223-0027/17, dated
16-01-2017,
SIQ Ljubljan,
Slovenia #
T251-0004/17, dated
05-01-2017
Hyundai Electric & Energy Systems Co. PDMS KERI, Korea # Based on S&SD letter # 16-05296-2-30504401
Ltd Type HiPDS-G (HiDAS) 2016TS00609, dated dated July 28,2016, it is prequalified for On-Line
SOUTH KOREA 09-03-2016, Partial Discharge Monitoring System (PDMS) and
Internal Sensor KERI, Korea # Internal Sensor as conforming to National Grid SA
Plant -Ulsan Type HiUC-P140 2016TS00627, dated Material Specification 38-TMSS-07 with the
18 Jan: - 23 Feb: following condition:
1000, Bangeojinsunhwan-doro, 2016,
Dong-gu, Ulsan, South Korea, KERI # •Ten (10) years extended warranty from the date
2016TS00755, dated of PAC of the turnkey project in case of contract
Ulsan 03 -04 March, 2016. award and date of delivery in case of direct
material supply order, as confirmed by the
Contact Person - Mr. Young Jun Bae manufacturer through letter # S370-1504-LSH3
(Regional General Manager) , Mr. Lee dated 31-07-2015.
Chung Hee (Vice President (Power
Infrastructure Sales & Marketing – II))
Phone - +966-11-293-2026, Previously Hyundai Heavy Industries Co. Ltd [The
+82-31-8006-6837 name has been changed based on P&SFD letter
Contact Person Email ID - #17-04234/01-030504401 dated May 24, 2017].
peterbae@hyundai-electric.com ,
kolch@hyundai-electric.com
Website -
http://www.hyundai-elec.com
APM TECHNOLOGIES INC APM Technologies KSA Type / Model: (PDMS) APM5000 & KERI # PQ Letter:
SOUTH KOREA APM Technologies KSA - APM2000 (Portable) 2014TS02416, dated S&SD letter # 14-08866-2-30504401 dated
Riyadh Second Industrial with UHF sensor 05 Aug, 2014, KERI December 11, 2014, it is pre-qualified for Partial
Plant -Seoul, Korea Republic Of City, # 2014TS02423, Discharge Monitoring System (PDMS).
Riyadh Saudi Arabia dated 05 Aug, 2014,
Mercedes-Benz Building 5F, 225-5, +966 53 66 77 212 KERI # WARRANTY:
Nonhyeon-Dong, Gangnam-Gu, Seoul jaypark@apmtech.co.kr 2014TS02444, dated Ten (10) years extended warranty/guarantee in
135-829, Korea 18-09-2014, KERI # respect of defects due to design, manufacture,
2014TS02568, dated installation & workmanship from the date of
Contact Person - Mr. JAY PARK 18 Aug. – 17 Sept. Provisional Acceptance Certificate (PAC) of the
Phone - + 82 2 545 6286,Mobile: +82 10 2014, KERI # first turnkey project in case of contract award or
5157 1255 2014TS02569, dated date of delivery in case of direct material supply
Email ID - jaypark@apmtech.co.kr 11 Aug- 15 Sept, order, as confirmed by the manufacturer thru
jaypark@psdholdings.com 2014, letter #nil, dt: May 12, 2014.
Website - http://www.apmtech,co,kr KOLAS #
STC-B14-375-01,
dated 18-22 –
09-2014, KOLAS,
Korea #
STC-B14-375-02,
dated 15-09-2014,
STC-B14-375-03,
dated
18-19-09-2014.
HYOSUNG HEAVY INDUSTRIES PD Monitoring System ,Type: GM-3000 Type tested in the PQ letter
CORPORATION (HICO) UHF Internal sensor presence of Based on S&SD letter # 15-09060-02-30504401
SOUTH KOREA type HiCMS-GM-IS, external Sensors SEC/National Grid dated December 09, 2015, it is pre-qualified for
type HiCMS-GEP-S-2, SA Engineers and PDM & Sensors with the following conditions:
Plant -Republic of Changwon, Korea UHF Noise sensor third party inspector
Type HiCMS-GNP-S-2 at KERI WARRANTY:
Eric Rhie, 450, Gongdeok-Dong, KERI, Korea # Ten (10) years Extended Guarantee / Warranty
Mapo-Gu, Seoul , Korea 2015TS02273, dated from the date of PAC of first Project (in case of
Tel:82-707-6180 10-11, August, contract award) or from the date of delivery for
2015, KERI, Korea # the direct material supply order. This is applicable
Contact Person - Mr. Jason Kang; Sale 2015TS02274, dated from first project and subsequently reduced
Manager & Mr. Young Kim; Sales 10-11, August, yearly in case of future project. This was
Manager 2015, KERI, Korea # confirmed, through their Letter No.
Contact Person Email ID - 2015TS02275, dated HS-PQ-150511-PDM-001 dated 17/07/2015.
Jason.kang@hyosung.com , 10, August, 2015,
yw.kim@hyosung.com Keri # 2015TS02508
Website - DATED 05-27
http://www.hyosung.co.kr/eng/index.js august, 2015, Korea
p?, www.hyosung.com testing & Research
Institute,
Korea #
CUS2015-3092,
dated 17-19 August,
2015, Korea testing
& Research Institute,
Korea #
KOMERI-0306-15T24
16-1, dated 20-21,
August, 2015
ABB S.R.O (RFF) ABB Automation CO. Ltd. UHF Sensor Type WB3 (1HC0034454) PHELA # 15020Ba PQ Letter:
CZECH REPUBLIC Saudi Arabia rated for 300/420 kV dated 14-16 April, Based on S&SD letter # 17-03926-2-30504401
PO Box # 414: 2015, PHELA # dated August 03, 2017, ABB S.R.O LBU Brno
Stetkova 1638/18,140 00 Praha 4Czech Riyadh-11383 15015Ba-1, dated Factory – Czech Republic is pre-qualified for
Republic-Trutnov +966 (11) 2653030, 08-17 April, 2015, Partial Discharge Sensor (UHF Sensor) type WB3
+966504401696 ABB, Switzerland # (1HC0034454) rated for 300/420 kV as
Contact Person - Mr. Essam essam.bashraheel@sa.a HASH650969E, conforming to National Grid SA specification #
Bashraheel & Mr Aref Al-Arrak bb.com dated 04-06, March, 38-TMSS-07 Rev.0 with the following conditions:
Email ID - 2014
Essam.bashraheel@sa.abb.com WARRANTY:
&Aref.alarrak@sa.abb.com •Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #
PGHV-17-04-26/GIS-1 dated June 16, 2017.
Total = 9
CONDITION:
All type, routine & special tests including the load
test shall be carried out on the first batch to be
supplied to SEC in securing an order in an
independent testing laboratory in the presence of
three (3) SEC engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
ELECTROTECNICA ARTECHE HNOS. Type / Model: Capacitive Voltage 1- For type 1- Type DDB-170
S.L./ E.A.H.S.L Transformer DDB-170, Test PQ Letter:
SPAIN Report # 2010 10 3D S&SD Letter 12-03192-02-30504001 dated
1 - DDB-72 0571 February 19, 2012, pre-qualified for CVT
Plant -Mungia, Spain Rating Capacitor Voltage Transformer up to 132 kV.
69 kV 2- For type
Electrotecnica Arteche Hnos. S.L./ DFK-420, " The first WARRANTY:
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea 2 - DDB-170 batch of 380kV Ten (10) years extended warranty/guarantee in
Nº28 48100/ Rating: Capacitor Voltage respect of defects due to design, manufacture,
132kV, CCVT Transformer (CVTs) installation & workmanship from the date of
Contact Person - Mr. Roberto Antuñano type DFK-420 per Provisional Acceptance Certificate (PAC) of the
Phone - +946011200 3 - DFK-245 50-TMSS-01, Rev.01 first turnkey project in case of contract award or
Email ID - ra@arteche.es Rating: to be supplied to date of delivery in case of direct material supply
Website - http://www.arteche.es 230kV, CVT SEC/National Grid order, as confirmed by the manufacturer thru
SA shall be type letter #nil, dt: jan 11, 2010.
4 - DFK-420 tested in an
Rating: accredited test 2- Type DFK-420
up to 380kV, CVT laboratory in PQ Letter
presence of three Based on S&SD letter MPQ # 10816213 dated
(3) SEC/National January 7, 2018, Electrotecnica ARTECHE
Grid SA and one (1) Hermanos, S.L. - Mungia, Spain is pre-qualified
SEC/National Grid for 380kV Capacitor Voltage Transformers
SA approved IIA (CVTs), type DFK-420 as conforming to National
Inspector as Grid SA specification # 50-TMSS-0,Rev.0, with
conformed through the following conditions:
Manufacturer Letter
# Nil dated Warranty
December 03,2017." Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
3. For type DFK-245, contract award) or date of first delivery (in case
Test Report # 2020 of direct material supply order), as confirmed,
01 3D 0021 through their letter # Nil, dated July 21, 2016 shall
be applicable for all 380kV Capacitor Voltage
4. For type DDB-72, Transformers (CVTs), type DFK-420 to be
The first batch of supplied to SEC/National Grid SA.
type DDB-72 to be
supplied to 3- Type DFK-245
SEC/National Grid PQ Letter:
SA shall be type Based on S&SD letter # 18-02331-030504401
tested in an dated July 8, 2018 Electrotecnica ARTECHE
accredited test Hermanos, S.L. - Mungia, Spain is pre-qualified
laboratory in for 230kV Capacitor Voltage Transformers
4.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
GE
United States
Website - http://www.ge.com/
Website -
http://www.passoni-villa.com
Website - http://www.ritzusa.com/
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
Website -
http://www.electricityforum.com/produ
cts/htg.htm
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
ABB HV TECHNOLOGIES
Swaziland
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Hitachi Energy Sweden AB Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
Total = 12
METERS
14. 1
METERING DEVICES (KILOWATT HOUR METER ENERGY METER) Applicable Standards: 40-TMSS-02
SIEMENS
GERMANY
ADVANCE ELECTRONICS CO., LTD. Type: USM-1 Type tests were PQ Letter
Saudi Arabia conducted in NMI Based on S&SD letter#19-00093-1-30504401
laboratory – dated January 27, 2019, the manufacturer is
Riyadh , Saudi Arabia Netherland prequalified for Metering Devices (Kilowatt Hour
30/04-11/05,2018 Meter, Energy Meter) as confirming to SEC
and 19-22/11,2018. specification #40-TMSS-02 Rev.0, with the
following conditions:
WARRANTY
Ten (10) years extended warranty in respect of
Type (ADDAD-4) the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #Nil dated
January 09, 2019.
ELSTER , ITS A3RAQ meters with configuration kEMA, Elster PREVIOUSLY ABB (T &D)
United States Riyadh KSA ZD3D44F00LD-16, ZD3E44F00LD-16, Engineering report
Phone - ZD3D46000LD-16. Test Date - Aug Based on S&SD Letter 12-00932-1-30504401
Plant -Raleigh, Nc,USA +966-56-666-2660 2011, Feb 2005 dated March 25, 2012, it is pre-qualified for
Email - A1860RALC meters with configuration Test Report No. - A3RAQ, A1860RALC and A1860RAL meters as
Elster Gmbh Otto-Hahn-Strasse 25 zia.shaban@its.sa ZE3KM4CF5LK-EL. 71240276-TIC confirming to SEC Specification # 40-TMSS-02,
D-68623 Lampertheim, Germany 6996-11, Rev.0 with the following condition:
Raleigh, Nc , United States A1860RAL meters with configuration PAKR-8ZNRH
ZE3KM4CF0LH-EL. Free Supply of Meter Type A3RAQ: Five (5)
Contact Person - Mr. Ali Mouslmani Revenue Meters Type A3RAQ shall be supplied
Email ID - ali.mouslmani@elster.com free of cost to SEC as confirmed through ELSTER
Website - http://www.elster.com/ letter # L1-ST12-001 dated January 21, 2012.
WARRANTY
Five (5) extended warranty/guarantee in respect
of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 12-01-2012.
GEC MEASUREMENT
United Kingdom
Website -
http://www.gecinstruments.com/
LANDIS + GYR AG-ZUG Saudi Masar High Tech Type/Model - [(E650 (ZXD) & E850 ZXQ Test Report No. - Based on S&SD Letter 14-04075-30504401 dated
SWITZERLAND Marketing Co. Rating - Cl 0.2s Active Cl 0.5 Reactive Yes April 2014 July 01, 2014, it is pre-qualified for Revenue
Industrial City, Phase 3, Meters Type E650 (ZXD) & E850 (ZXQ)
Landis+Gyr Ag Zug/Switzerland Jeddah CR No conforming to National Grid SA specifications #
Theilerstr. 1 63O1 Zug,Switzerland. 4030118442, 40-TMSS-03, Rev.1 and 40-TMSS-02 Rev.0 with
Zug , Switzerland Phone - 0096612608 the following conditions:
0581
Contact Person - Mr. Akhlak WARRANTY
Husain,Area Manager. Ten (10) years extended warranty/guarantee in
Phone - +971 558854159 respect of defects due to design, manufacture,
Email ID - AkhIak.husain@landisgyr.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 30, 2014.
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by TYCO Electronic UK
through their letter # INT-SEC-06 dated January
03, 2008 and its Amendment dated Nov 21, 2011.
Elster Rometrics SRL ITS – Ideal Technical Meters type A1800 with models A1884 Type tests PQ Letter:
Romania Solutions RALNC, A1822 RALNC, A1860 RALC. successfully Based on S&SD letter # MPQ #13226714 dated
3135 Prince Sultan Bin completed on 22-29 March 17, 2022., the manufacturer is prequalified
Plant -Romania Abdulaziz Rd, As April 2019 in for METERING DEVICES (KILOWATT HOUR
Sulimaniyah, Riyadh DNV-GL (KEMA) METER ENERGY METER), as conforming to
Timisoara Airport Park 12232 7908 report #1019-20 & National Grid SA specification #40-TMSS-02, with
307210 Giarmata +966 56 666 2660 72129424. the following conditions:
Timis county Zia.shaban@its.sa
Romania WARRANTY:
Ten (10) years extended warranty from the date
Contact Person - Maritass Comia of PAC of the first turnkey project (in case of
Phone - +40 256 49 98 99 contract award) or date of first delivery (in case
Email ID - elster.rometrics@elster.com of direct material supply order), as confirmed,
Contact Person Email ID - through their Letter # Nil dated April 10, 2017 shall
maritass.comia@honeywell.com be applicable for the equipment to be supplied to
Website - www.elstersolutions.com SEC/National Grid SA.
Total = 9
METERS
14. 2
METERING DEVICES (AMMETER, VOLTMETER, MW, MVAR) Applicable Standards: 40-TMSS-02
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
CELSA, ITALY
ITALY
Italy
Website - http://www.celsa.com/
Website - http://www.cewe.com/
WARRANTY
ENTES (Turkey) has agreed to give SEC a
Guarantee/ Warranty on the proposed digital
meters for a period of two (02) years and eight
(08) years (for maintenance) for total of ten (10)
years from the date of PAC of the turnkey project
in case of contract award or date of delivery in
case of direct material supply order.
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by TYCO Electronic UK
through their letter #INT-SEC-06 dated January
03, 2008 and its Amendment dated Nov 21, 2011.
Total = 7
METERS
14. 3
AUTOMATIC METER READING (AMR) SYSTEM INTEGRATOR, AUTOMATIC METER READING Applicable Standards: 40-TMSS-03 (Rev.0)
(AMR) SYSTEM
ADVANCE ELECTRONICS CO., LTD. Based on approval of Executive Directive for
Saudi Arabia TS&SD Letter # 08-1105-03032301 dated
20/10/2008, it is pre-qualified for Energy Meters
Riyadh , Saudi Arabia Type (ADDAD-4) & Quality Meters
Type(SEL-734).
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery in case
of direct material supply order as confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter # W1-NG01-J13-001 dated January
08, 2013 and L1-ST12-020 dated December 03,
2012.
Total = 2
METERS
14. 4
ADVANCED METERING INFRASTRUCTURE (AMI) SYSTEM INTEGRATOR Applicable Standards: 40-TMSS-03 (Rev.01)
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
or date of first delivery (in case of direct material
supply order), as confirmed, through their Letter
#AEC 65/2/16/298 dated August 08, 2020 shall be
applicable for the equipment to be supplied to
SEC/National Grid SA.
Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.
Plant -2Nd Industrial Area,Riyadh,, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Riyadh
Based on S&SD Letter 16-09613-1-30504401
Contact Person - Mr. Ahmed Abubasha dated Dec 12, 2016, it is pre-qualified for AMI
Contact Person Email ID - system with as conforming to National Grid SA
Ahmed.Abubasha@hitachienergy.com Specification # 40-TMSS-03, Rev.01 with the
following conditions:
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter #PSN/SAS/0429/2014 dated 29 April, 2014.
Riyadh WARRANTY
• Ten (10) years extended warranty in respect of
Contact Person - Mr. Bruno Stocchi the defects due to design, manufacturing,
Contact Person Email ID - installation and workmanship from the date of the
majed@sep.com.sa, Provisional Acceptance Certificate (PAC) of the
bruno@sep.com.sa first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter No. SEP/AMI/2015/06 dated September
15,2015.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery in case
of direct material supply order as confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter #W1-NG01-J14-001 dated January
01,2014 and Letter#L1-NG01-J14-001 dated
December 03, 2013.
CONDITION
System Demo: Live Demo of the AMI System will
be conducted in presence of SEC/National Grid
SA Engineers on the first system to be
manufactured in SEP factory already confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter #L1-NG01-J14-002, dated January
06,2014.
Total = 8
METERS
14. 5
REVENUE METER Applicable Standards: 40-TMSS-03
ADVANCE ELECTRONICS CO., LTD. Type: USM-1 Type tests were PQ Letter
Saudi Arabia conducted in NMI Based on S&SD letter#19-00093-1-30504401
laboratory – dated January 27, 2019, the manufacturer is
Riyadh , Saudi Arabia Netherland prequalified for Revenue Meter as confirming to
30/04-11/05,2018 SEC specification #40-TMSS-03 Rev.01, with the
and 19-22/11,2018. following conditions:
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
Energy Meters Type (ADDAD-4) supply order shall be provided as confirmed by
the manufacturer through their letter #Nil dated
January 09, 2019.
LANDIS + GYR AG-ZUG Revenue Meters Type E650 (ZXD) & PQ Letter
SWITZERLAND E850 (ZXQ) Based on S&SD Letter 14-04075-30504401 dated
July 01, 2014, it is pre-qualified for Revenue
Landis+Gyr Ag Zug/Switzerland Meters Type E650 (ZXD) & E850 (ZXQ)
Theilerstr. 1 63O1 Zug,Switzerland. conforming to National Grid SA specifications #
Zug , Switzerland 40-TMSS-03, and 40-TMSS-02 with the following
conditions:
Contact Person - Mr. Akhlak
Husain,Area Manager. WARRANTY
Phone - +971 558854159 Ten (10) years extended warranty from the date
Email ID - AkhIak.husain@landisgyr.com of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
by the manufacturer through their letter # Nil,
dated January 30, 2014.
Elster Rometrics SRL ITS - Ideal Technical Meters type A1800 with models A1884 Type tests PQ Letter
Romania Solutions RALNC, A1822 RALNC, A1860 RALC. successfully Based on S&SD letter #MPQ 13226714 dated
3135 Prince Sultan Bin completed in March 17, 2020, the manufacturer is prequalified
Plant -Romania Abdulaziz Rd, As DNV-GL (KEMA) for Revenue Meter as conforming to National Grid
Sulimaniyah, Riyadh report #1019-20 & SA specification # 40-TMSS-03, with the
Timisoara Airport Park 12232 7908 72129424. following conditions:
307210 Giarmata +966 566662660
Timis county Zia.Shaban@its.sa CONDITIONS
Romania The manufacturer is not allowed to quote for any
SEC/National Grid SA , project/purchase order
Contact Person - Maritass Comia whenever there is change in plant location &
Phone - +40 256 49 98 99 change in design, till evaluated and approved by
Email ID - elster.rometrics@elster.com SEC/National Grid SA.
Contact Person Email ID - Whenever there is a change of authorized
maritass.comia@honeywell.com contact person, SEC/National Grid SA shall be
Website - www.elstersolutions.com informed with new contact details to update our
database.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter # Nil dated April 10, 2017 shall
be applicable for the equipment to be supplied to
SEC/National Grid SA.
WARRANTY
Five (5) years extended warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order as confirmed through
ELSTER letter # NIL dated 12-01-2012.
Total = 6
METERS
14. 6
POWER QUALITY METER Applicable Standards: 40-TMSS-03
ELECTRO INDUSTRIES / GAUGETECH Power Quality Meters type NEXUS Yes PQ Letter
United States 1500 Based on S&SD Letter 13-00862/03-030504401
dated April 20, 2013, Electro Industries/
New York United States GaugeTech, New York, USA is pre-qualified for
Power Quality Meters type NEXUS 1500 as
conforming to National Grid SA specification #
40-TMSS-03, Rev.0, with the following
conditions:
CONDITION:
Product Support: Continuous supply and product
support of Power Quality Meters type NEXUS
1500 to all SEC/ National Grid SA approved AMR
Manufacturers for a minimum period of ten (10)
years shall be ensured as confirmed through
their letter # Nil dated January 01, 2012.
WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or from the date of first delivery
of direct material supply order as confirmed by
Electro Industries /Gauge Tech -New York, USA
through their letter # L1-NG01-J13-004 dated
January 29, 2013.
Total = 2
PROTECTIVE RELAYS
15. 1
380 KV and Below Applicable Standards: 41-TMSS-01
Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
L90-
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
L90-
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Relay Type:
L90
L90-
CH2 to be attenuated to fit SDH
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
L90
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports
L90
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports
Hitachi Energy Sweden AB Hitachi Energy Relay Type: Mfr. Name change from ABB Sweden AB to
SWEDEN Hitachi Energy Ltd. Hitachi Energy Sweden AB
Riyadh, Saudi Arabia RED670*1.2
Plant -Natverksgatan 3 Bnr 391: 721 36 Phone: +966 11 2181703
Vaesteras Mobile: +966 500414555 Function:
paulus.ralhana@hitachie 87L(Dual Combined Slope)
Contact Person - Mr. Paulus Ralhana nergy.com 21P&G(5 Zones,Quad+Mho+Bi)
(manager) 67DEF with comm. Schem
Email ID - 79(2CBs OR 1CB controlled)+25
paulus.ralhana@hitachienergy.com 50/51PH&GR/SEF/46
Contact Person Email ID - 67P/67N
paulus.ralhana@hitachienergy.com 49 Thermal overload
Website - www.hitachienergy.com 27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’s+12BO’s
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
RED670*1.2
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’s+12BO’s
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Relay Type:
RED670*1.2
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Relay Type:
RED670*1.2
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Function:
87T (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
2-WINDING:
14xCT(Ph)+4xCT(Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2-ports
RET670*1.2-
Function:
87T (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
Hardware:
3-WINDING:
14xCT(Ph)+4xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
REB500 CU
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
CT Supervision
Intertrip facility
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
24 PU connected to CU
IEC 61850, 2-PORTS
REB500
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
CT Supervision
Intertrip facility
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
48 PU connected to CU
IEC 61850, 2-PORTS
:
REB500 PU
FP1-PD0-DR0-L0-T0+1MRB150073R00
52
Function:
50BF: stage1
50BF: stage2
End fault protection with Interntrip or
Dead Zone
HMI
DFR/SOE
Hardware:
PU: 4CT+16BI’S+12BO’S
REC670
Functions:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE
Hardware:
6CT+6VT+16BI’s+24BO’s
IEC 61850,2-PORTS
RED670*1.2
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT+6VT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 850nm, CH-2 850nm (up to 3km)
IEC 61850 -2 Ports
Relay Type:
RED670
RED670*1.2
-XE
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT+6VT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1310nm, CH-2 1310nm (up to
80km)
IEC 61850 -2 Ports
REC670
Function:
87 3-Phase High Z Differential
(based on Voltage)
50/51N
Internal CT Bus Wire Supervision
(based on voltage )
74TC Trip circuit Supervision
External Stabilizing
Resistor
External Metrosil
External CT Shorting
Hardware:
6I+6U
24BO
16BI
IEC 61850,2-Optical Ports (PRP)
REB650
Function:
87 3-Phase High Z Differential
(based on Voltage)
50/51N
Internal CT Bus Wire Supervision
(based on voltage )
74TC Trip circuit Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
6I+4U
27BO
18BI
IEC 61850,2-Optical Ports (PRP)
REL670*1.2
Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67P/67N
49 Thermal Overload
Phase unbalance 46
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16 BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Other Type:
REQ 650
50/51/50N/51N/50BF/50BF/87 High
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
0411L
Function:
87L
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
27/59/59N
50BF
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Type/Model - 487V
Rating - 380/132/115/110/69/33/13.8kV
Functions:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE
Hardware:
6CT+6VT+15BI’s+23BO’s
IEC 61850,2-PORTS
SEL411L
Function:
Line diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports
0411L
Function:
Line diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports
Hardware:
4CT+4VT+12BI’s+12BO’s
8CT+4VT+16BI’s+16BO’s
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
P546
Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’s+12BO’s
8CT+4VT+16BI’s+16BO’s
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Micom P643
Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instantaneous Diff
50/51PH&GR all windings
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC Supply Supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
2-WINDING:
9xCT (Ph) + 4xCT (Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2-ports
P645
Functions:
27/59/25
81 U/O
50 BF
49T
24
74 DC Supply Supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
15xCT(Ph)+3xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
MICOM P740 PU
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage2
CT Supervision
Intertrip facility
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’S+8BO’S
24 PU connected to CU
IEC 61850, 2-PORTS
MICOM P740
Function:
50BF: stage1
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
HMI
DFR/SOE
Hardware:
PU: 4CT+16BI’s+12BO’S
IEC 61850, 2-PORTS
MiCOM P543
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (5CT+4VT)
Binary Inputs – 16 Inputs
Binary Outputs 14
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports
P5433
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (5CT+4VT)
Binary Inputs – 16 Inputs
Binary Outputs 14
CH-1 1300nm, CH-2 1300nm (up to
50km)
IEC 61850 -2 Ports
MCAG34
Function:
87 3-Phase High Z Differential (Current
Base)
External CT Bus Wire Supervision
External stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
3 CT Inputs
2 Output Contacts
Ordering code:
MCAG14SSD**** *A
Built in Function:
87 3-Phase High Z Differential
(Current Base)
External CT Bus Wire Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
1 CT Phase Inputs
2 Output Contacts
MFAC
Built in Function:
Hardware:
1 elements / phases voltage based
4 Output Contacts
Other Type:
MICOM P142
87 3-Phase High Z
50BF
Differential, 50/51N, CT Bus-wire
Supervision (95), TCS : Trip Circuit
Supervision, 74 DC supply supervision
27/59/59N,
Breaker Failure (50BF) 74DC DC
SUPPLY SUPERVISION, 67P/67N,
Under / Over
Frequency 81, Under current 37, 60VT
Supervision, DFR
/SOE/F Locator
MICOM P143
25
MICOM P443
Distance/85
MICOM P841
25/79
- REF620
REF620
Function:
Multi-stage overcurrent and earth fault
50/51, 50N/51N
Undercurrent 37
Over and under voltage 59/27
synchrocheck 25
over and under frequency 81
Auto-reclose 79
CT and VT supervision 60
Trip circuit supervision 74TC
Circuit breaker failure 50CBF
High impedance bus bar protection,
External Stabilizing Resistor
External Metrosil
External CT Shorting
IEC 61850 Ed.2 with PRP
SCHNEIDER ELECTRIC Schneider Electric EPS Type/Model - 8 Models of MICOM Test Date - April Old Comments:
United Kingdom Ltd P546 2014 PQ Letter
PO Box 89249 Riyadh Based on S&SD letter # 14-040883-2-30504401
Plant -United Kingdom-Stone 11682 Saudi Arabia Functions: 87L, Under current dated June 12, 2014, M/s Schneider Electric from
Phone - 37,Inrush Blocking, Under / over United Kingdom – stone is prequalified for MiCOM
Schneider Electric Energy Ltd Unit 9 +966-11-291-28-77 x Frequency 81,open conductor P546 as per the following conditions:
Opal Way Stone Business Park Stone 360 protection, Second harmonic detection,
St15 0Ss United Kingdom Stone , United Email - 21P&G, 67DEF, 79 (1 CB or 2 CB) CONDITION:
Kingdom padma.raja@schneider- controlled + 25, SEF, 50/51PH&GR / Type tests shall be carried out on the MiCOM
electric.com SEF/46, 67P/ 67N ,49 Thermal P546 relays as per new IEC 61850-10 (2012-12)
Contact Person - Mr. Paul Kerr Overload, 27/59/59N, 50BF, 74 DC edition 2 in the approved Independent Testing
Phone - +44 7917 534038 supply supervision, 74 Trip circuit laboratory witnessing by three (3) National Grid
Email ID - supervision, CT Supervision, 60 VT SA engineers and one (1) approved Independent
paul.kerr@schneider-electric.com Supervision, DFR/SOE / Fault Locator Agency Inspector (IIA). All costs of witnessing
Website - Hardware: 8xCT(Ph) + 5xVT, 32 Digital the tests shall be borne by the manufacturer as
http://www.schneider-electric.com Inputs, 24Digital Outputs, Protection per their confirmation through letter # Nil dated
data interface-1 850, October 23, 2013.
Protection data interface-2 850,
IEC61850, 2 x WARRANTY:
Ten (10) years extended warranty/guarantee in
port(PRP) respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Functions: 87L, Under current first turnkey project in case of contract award or
37,Inrush Blocking, Under / over date of delivery in case of direct material supply
Frequency 81,open conductor order.
protection, Second harmonic detection,
21P&G, 67DEF, 79 (1 CB or 2 CB) PQ Letter
controlled + 25, SEF, 50/51PH&GR / Based on S&SD letter # 14-040883-2-30504401
SEF/46, 67P/ 67N ,49 Thermal dated June 12, 2014, M/s Schneider Electric from
Overload, 27/59/59N, 50BF, 74 DC United Kingdom – stone is prequalified for MiCOM
supply supervision, 74 Trip circuit P543 as per the following conditions:
supervision, CT Supervision, 60 VT
Supervision, DFR/SOE / Fault Locator CONDITION:
Hardware: 8xCT(Ph) + 5xVT, 32 Digital Type tests shall be carried out on the MiCOM
Inputs, 24Digital Outputs, Protection P543 relays as per new IEC 61850-10 (2012-12)
data interface-1 1300, Protection data edition 2 in the approved Independent Testing
interface-2 850, IEC61850, 2 x laboratory witnessing by three (3) National Grid
port(PRP) SA engineers and one (1) approved Independent
Agency Inspector (IIA). All costs of witnessing
the tests shall be borne by the manufacturer as
Functions: 87L, Under current per their confirmation through letter # Nil dated
supervision, CT Supervision, 60 VT
Supervision, DFR/SOE / Fault Locator
Hardware: 5xCT(Ph) + 4xVT, 16 Digital
Inputs, 14 Digital Outputs, Protection
data interface-1 1300, Protection data
interface-2 1300, IEC61850, 2 x optical
port(fiber) (PRP)
Other Type:
MICOM P139
27/59/UVLS/UFLS
SIEMENS SIEMENS Ltd Saudi (SIPROTEC 4); (SIPROTEC 5): (SIPROTEC 5):
GERMANY Arabia Relay Type: Type test Report # Based on S&SD letter # 17-00825-30504401
Khaleel.al-adani@siemen 7SD522 G0M-1412-4383-S0 dated March 14, 2017, Siemens Berlin, Germany
Berlin, Germany s.com C000-V01 is pre-qualified for Protective Relays as
IC SG EA MF Local: Mr. Khaleel Dated: December conforming to National Grid SA specification #
Wernerwerkdamm 5, Al-Adani Function: 2014 41-TMSS-0,Rev.0, with the following conditions:
13629, Berlin, Germany Mob: +966 505892043 87L(Dual Combined Slope) Laboratory: •Ten (10) years extended warranty from the date
+966126618831 21P&G(5 Zones,Quad+Mho+Bi) Eurofins Product of PAC of the first turnkey project (in case of
Phone - +49 (911) 433 8321 Khaleel.al-adani@siemen 67DEF with comm. Schem Service GmbH contract award) or date of first delivery (in case
Website - s.com 79(2CBs OR 1CB controlled)+25 of direct material supply order), as confirmed,
www.siemens.com/ingenuityforlife 50/51PH&GR/SEF/46 & RTDS Test Report through their letter # EA PRO/Pz, dated April 22,
67P/67N # EM DG PTI PSC / 2014 shall be applicable for all protective relays
49 Thermal overload pc200768 / VH to be supplied to SEC/National Grid SA.
27/59/59N Dated December
50BF 2016
74DC supply supervision Laboratory: (SIPROTEC 5):
74 trip relay Coil Supervision Siemens Germany PQ Letter:
CT Supervision AG Based on S&SD letter # 17-00825-30504401
60 VT Supervision dated March 14, 2017, Siemens Berlin, Germany
DFR/SOE /F locator (FOR TYPE 7SA8X) is pre-qualified for (SIPROTEC 5) as conforming
Type Tests to National Grid SA specification # 41-TMSS-0
Hardware: successfully
4CT+4VT+12BI’S+12BO’S completed at WARRANTY:
CH-1 1300nm, CH-2 850nm EUROFINS, Ten (10) years extended warranty from the date
IEC 61850,2-PORTS AUCOTEAM and of PAC of the first turnkey project (in case of
PRO-EMV Germany contract award) or date of first delivery (in case
from 17th to 26th of direct material supply order), as confirmed,
7SD522 February 2016 Test through their letter # EA PRO/Pz, dated April 22,
report No. 2014 shall be applicable for all (SIPROTEC 5
Function: 11635316. Relays) to be supplied to SEC/National Grid SA.
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi) PQ Letter:
67DEF with comm. Schem Type Tests Based on S&SD letter # 17-00825-30504401
79(2CBs OR 1CB controlled)+25 successfully dated March 14, 2017, Siemens Berlin, Germany
50/51PH&GR/SEF/46 completed at ( is pre-qualified for (SIPROTEC 5) as conforming
67P/67N KEMA, Aucoteam to National Grid SA specification # 41-TMSS-0
49 Thermal overload and SIEMENS )
27/59/59N WARRANTY:
50BF Ten (10) years extended warranty from the date
74DC supply supervision of PAC of the first turnkey project (in case of
74 trip relay Coil Supervision contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1550nm (100km)
Protection Interface 2:820nm (1.5km)
IEC61850 -PRP x 2 FO ports
Type 7SL86
functions :
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1300nm (60km)
Protection Interface 2:820nm (1.5km)
IEC61850 -PRP x 2 FO ports
Type 7SL86
Ordering code:
7SL86-P1C40594
Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1550nm (100km)
(SIPROTEC 4):
7UT6
Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
CT Super (All windings)
60
DFR/SOE
Hardware:
2-WINDING:
9xCT(Ph)+4xCT(Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
7UT6
Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
12xCT(Ph)+4xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
(SIPROTEC 5):
Type 7UT85
functions:
87T Dual combined slop
87REF low Impedance
87REF High Impedance
87/50 Instantaneous Diff
50/51PH&GR All Windings
67/67N All Windings
27/59/25
81U/O
50BF
49T
24
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE
Hardware:
9 PH CT + 3 GND CT
4 VT
21 BI
28 BO
IEC61850 -PRP x 2 FO ports
7SS52x CU
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
24 PU connected to CU
IEC 61850, 2-PORTS
Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
7SS5231-
Built in Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
PU: 4CT+16BI’s+12BO’S
(SIPROTEC 4):
7SA6x
Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67N
49 Thermal Overload
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16 BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
(SIPROTEC 5):
Type 7SL86
functions:
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)
(SIPROTEC 4):
7SJ64
Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
15BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
7SD52
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
Ordering code:
7SD5221
Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports
7SJ64
Function:
87 3-Phase High Z Differential
(based on current)50/51N
Internal CT Bus Wire Supervision
(based on current )
74TC Trip circuit Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
4 CT Inputs
13BO
15BI
IEC 61850, 2-Optical Ports (PRP)
Type 7VK87
Functions:
Breaker Failure 50BF
Synch Check 25
79
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE
Hardware:
4 CT
4 VT
11 BI
09 BO
IEC61850 -PRP x 2 FO ports
Type 7SL86
Functions:
87L
21P&G
50/51 PH&GR
49
PHASE UNBALANCE
79
50BF
Inrush Blocking
81
Sensitive Earth element
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22 BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)
IEC61850 -PRP x 2 FO ports
Type 7SJ82
Ordering code:
7SJ82-P1J66121
Functions:
SEND / RECEIVE remote/local
COMMANDS
Supervision & Monitoring Functions:
CT supervision
74TC
74DC Supervision
74 Lockout Supervision
DFR/SOE
Hardware:
4 CT
11 BI
09 BO
Protection Interface 1:1550nm (100km)
Protection Interface 2:1550nm (100km)
IEC61850 -PRP x 2 FO ports
Other Type:
6MD61
I/O
7UT6
50/51
7RW80
27/59/UVLS/UFLS
7SA522
85
7VK61
25/79/50BF/27/59
TYPE 7SA8X
Function
21
21N
68
78
85
50/50N /51/51N
50BF
67/67N/79/25
81
27
59
7SJ80
SIPROTEC 4 Compact
(50/51/50BF/50N/51N/67/67N/87N/79/2
5/81/27/59)
TYPE 7SJ8x
Function:
50N/51 P&GD
High Impedance Protection
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Total = 8
PROTECTIVE RELAYS
15. 2
132 KV and Below Applicable Standards: 41-TMSS-01
GE MULTILIN T 60 ON HOLD
CANADA
Hardware:
2-WINDING:
15xCT(Ph)+5xCT(Gnd)
8xcontact inputs
4xcontact outputs
3-WINDING:
IEC 61850 2-ports
Ordering code:
T60-K22-HKH-F8F-H6L-M8N-P6T-U8N-
WXX
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
15xCT(Ph)+5xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
C70
Functions:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE
Hardware:
6CT+6VT+16BI’s+20BO’s
IEC 61850,2-PORTS
Hardware:
2-WINDING:
8xcontact inputs
4xcontact outputs
3-WINDING:
15xCT(Ph)+3xCT(Gnd)
SEL421
Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
15BI+23 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
8IDV
Function:
87L (dual combined slope)
87 REF (low impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67N/67N(All windings)
50 BF
49T
74 DC supply supervision.
74 Lockout Coil Supervision.
CT Super (All windings)
DFR/SOE
Hardware:
3-WINDING:
12xCT(Ph)+2xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
Other Type:
6RTV
AVC
Total = 3
PROTECTIVE RELAYS
15. 3
33 KV and Below Applicable Standards: 41-TMSS-01
SEL SEL-451
United States
Website - Function:
http://www.selindustrial.com/ Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
14BI+6 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Total = 3
PROTECTIVE RELAYS
15. 4
13.8 KV and Below Applicable Standards: 41-TMSS-01
ZIV 7IRV
SPAIN 50/51/50N/51N/67/67N/50BF
GE MULTILIN F650
SPAIN
Functions:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Hardware:
16 BI+ 07 BO
3CT(Ph) + 1CT(GD)+3VT
IEC 61850, 2-Optical Ports PRP
Total = 3
PROTECTIVE RELAYS
15. 5
Auxiliary Relays Applicable Standards: 41-TMSS-01
Hitachi Energy Sweden AB Hitachi Energy Type/Model – combiflex RXMVB2 Mfr. Name change from ABB Sweden AB to
SWEDEN Hitachi Energy Ltd. Hitachi Energy Sweden AB
Riyadh, Saudi Arabia Built in Function:
Plant -Natverksgatan 3 Bnr 391: 721 36 Phone: +966 11 2181703 CT Shorting
Vaesteras Mobile: +966 500414555 Hardware:
paulus.ralhana@hitachie
Contact Person - Mr. Paulus Ralhana nergy.com
(manager) Other Type:
Email ID - RXKL1
paulus.ralhana@hitachienergy.com Timer
Contact Person Email ID -
paulus.ralhana@hitachienergy.com RXMB1
Website - www.hitachienergy.com
RXMVB4
In/Out relay
RXSF1
DC supervision
SPER 1C1
Trip circuit supervision
Hardware:
Other Type:
MVAA
multiplication relay
MVAJ104
In/Out relay
MVAJ34
in/out relay
MVAX12
DC supervision
MVAX31
Trip circuit supervision
MVTT14
Timer
SIEMENS AR 901
GERMANY
Function:
Plant -Berlin. Germany CT Shorting
Total = 5
PROTECTIVE RELAYS
15. 6
Tripping and Lockout Relay Applicable Standards: 41-TMSS-01
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
MVAJ105
Standard Specification :
Hand & Electrical Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case.
ELECTRO-SWITCH LOR/HR
United States
LOR/HR-
Website -
http://www.electroswitch.com/ Standard Specification :
Hand & Electrical Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
LOR/SR-
Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
RELAY MONITORING SYSTEM (RMS) Relays group of High Speed Tripping Relay , Type test witnessed PQ Letter
AUSTRALIA Companies Type: 6RJ21 by three Based on S&SD letter # 15-02815-2-030504401
P.O. Box 101709 , SEC/National Grid dated 30 June 2015, the manufacturer is
6 Anzed Court Mulgrave 3170 Riyadh 11665 Kingdom High Burden Tripping Relay , SA Engineers during prequalified for: High Speed Tripping Relay, Type:
Melbourne Victoria Australia Po Box of Saudi Arabia Type: 6RJ25 25th May-3rd June 6RJ21
1166 Huntingdale Tel: 00 9661 Ordering Code: 6RJ25-10-D-8M2B 2015.
4727902/4724320/47324 Test were As conforming to National Grid SA specification #
Contact Person - Mr. Alphonse 61 - Fax: 00 966 Conducted in RMS 41-TMSS-01,
Fernandez Export Manager E-Mail: Lab and Report No. Rev.0 with the following condition:
Phone - +61-3-8544-1200 thuraibi@erelaysgroup.c 19301901001 (TUV)
Email ID - rms@rmspl.com.au , om, rbakshi@erelays SEC Report#Nil WARRANTY:
Alphonse.fernandez@rmspl.com.au Dated 14-10-2014 Ten (10) years extended warranty from the date
Website - http://www.rmspl.com.au of PAC of the first turnkey project in case of
contract award and subsequently reduced
yearly (in case of future project award). and
from the date of first delivery in case of direct
material supply order. This was confirmed in
writing by the manufacturer, as confirmed by the
manufacturer thru letter #nil dt: Nov 07, 2013.
SIEMENS TR241
GERMANY
Standard Specification :
Berlin, Germany Hand & Electrical Reset
IC SG EA MF High Burden
Wernerwerkdamm 5, Flag indication, hand reset
13629, Berlin, Germany Up to 10 contracts (in any
configuration)(8 NO & 2 NC)
Phone - +49 (911) 433 8321 Standard Hand Reset Flag Available
Website - Operating Time in ms. (10ms)
www.siemens.com/ingenuityforlife Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case
TR212
Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Up to 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with
Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case
Total = 5
Fault Recorder/Locator
16. 1
DIGITAL/TRANSIENT FAULT RECORDERS Applicable Standards: 41-TMSS-02
DIgSILENT Al Haider For Trading & PFM 300 Type tests were Letter
GERMANY Contracting conducted in Based on S&SD letter # 16-10016-030504401
P.O. Box 18. Ras Tanura, DigSILENT test lab dated December 25, 2016, DIgSILENT,
Plant -Gomaringen Germany 31941,m KSA and S-Team Gomaringen Germany is pre-qualified for Digital
+966 3 667 0552 / 667 Electronic test lab Fault Recorder type PFM 300 as conforming to
Heinrich-Hertz-Strabe 9 3700 / 667 1660 during 21st to 23rd National Grid SA specification # 41-TMSS-02
72810 Gomaringen alhaiderpersonnel@yaho September 2016 Rev.0, with the following condition:
o.com /
Contact Person - Dr. Martin Schmieg, salahf4@yahoo.com warranty
Managing Director •Ten (10) years extended warranty from the date
Contact Person Email ID - of PAC of the first turnkey project (in case of
m.schmieg@digsilent.de contract award) and date of first delivery (in
Website - http://www.digsilent.de case of direct material supply order), as
confirmed, through their Letter No. Nill dated 12
August 2014 shall be applicable for all supplies to
the Company by DIgSILENT, Gomaringen
Germany
KoCos Messtechnik Germany Mohammed Al-Ojaimi SHERLOG CRX •Fault Record PQ letter:
GERMANY Contracting Est. System Report # Based on S&SD letter # 17-06723-030504401
KoCoS Messtechnik AG (E170309E1) by dated October 31, 2017, KoCos Messtechnik
Plant -Korbach, Germany Suedring 42 Phoenix TestLab – Germany is pre-qualified for Digital Fault
D-34497 Korbach, Germany Recorder (DFR) as conforming to latest National
KoCoS Messtechnik AG Germany •DFR & DSM Report Grid SA specification # 41-TMSS-02
Suedring 42 Tel. +49 5631 9596-0 # (U170309E1) by
D-34497 Korbach, Germany info@kocos.com Phoenix TestLab – WARRANTY:
Germany Ten (10) years extended warranty/guarantee in
Korbach •Functional Test respect of defects due to design, manufacture,
Report # Nill by installation and workmanship from the date of
Contact Person - KoCos Germany KoCos Messtechnik Provisional Acceptance Certificate (PAC) of the
(Lea-Sophie Kotthoff, Sales), Local – Germany first turnkey project in case of contract award or
Agent- Mohammed Al-Ojaimi date of first delivery in case of direct material
Contracting Est. (Abbad S. Ahmed, supply order, as confirmed by the manufacturer
Manager Energy Services.) vide letter # Nil, dated May 27, 2015.
Phone - Tel. +49 5631 9596-0
Email ID - info@kocos.com
Contact Person Email ID -
lkotthoff@kocos.com
abbad.ahmed@alojaimi.com
Website - www.kocos.com
AMETEK (ROCHESTER)
United States
Plant -ROCHESTER, NY
ROCHESTER, NY
ERL PHASE POWER TECHNOLOGIES Diyar Al Mobtekroon Int. TESLA 4000 ON HOLD
LTD Co.\PO Box 89109
CANADA Riyadh 11682 KSA
Eng. Ali Al Ameel Based on S&SD letter # 15-01879/02-030504401
74 Scurfield Blvd, Winnipeg, Mb a.alameel@diyarksa.com dated April 28, 2015, the manufacturer is
Canada R3Y 1G4 info@diyarksa.com prequalified to supply Fault Recorder with the
following conditions:
Contact Person - Mr. Ramaswami
Bharath - Ten (10) years extended for the Fault recorder
Phone - +204-477-0591 , from the date of PAC of the turnkey project in
Email ID - Info@erlphase.com case of contract award or date of delivery in
Website - http://www.erlphase.com case of direct material supply order. as
confirmed through the manufacturer letter # Nil
dated 18.10.2013.
Total = 5
CAPACITOR
17. 1
SHUNT CAPACITOR BANK, 13.8KV THROUGH 380KV Applicable Standards: 43-TMSS-01
GRID SOLUTIONS OY LTD. Previously " Nokian Capacitors Ltd. –Finland", the
FINLAND name has been changed to Areva T&D Ltd. –
Finland based on TS&SD/ESD Letter #
Tampere , Finland 10-00145-03032301 dated January 16, 2010 and
P.O.Box 4, Kaapelikatu 3 fl-33331 Areva T&D Ltd.-Finland Letter # Nil dated January
Vehmaistenkatu 5 fl-33730 04, 2010, then the name has been changed again
to ALSTOM Grid Ltd. –Finland based on Dept Mgr,
Phone - +358 3 388311 S&SD E-mail dated February 26, 2012 and
Email ID - firstname.surname@ge.com ALSTOM Grid Ltd. letter # RN-2012-02-18 dated
Website - www.gegridsolutions.com February 18, 2012.
SAMWHA CAPACITOR CO. LTD Type / Model: Shunt Capacitor Banks PQ Letter:
KOREA, Republic of TS&SD Letter # 11-02016/01-03032301 dated
Rating: 13.8kV to 36kV Only 06/07/2011, it is pre-qualified for Substation Type
13.8kV to 36kV Only Shunt Capacitor Banks.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.nil, dt: 12/03/2010..
Hitachi Energy Ltd. CHDX, CHDB/ Shunt Capacitor Bank (18 January to 11 Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia (Q-Bank) March 2021), FGH and changed to Hitachi Energy Ltd.
Rating: 13.8kV through 380kV CESI lab Germany
Plant -Dammam PQ Letter
Based on S&SD letter # OMPQ35358417 dated
Dammam June 01, 2021, the manufacturer is prequalified
for Shunt Capacitor Bank , 13.8KV Through
Contact Person - Abdulmajeed 380KV confirming to National Grid SA
Alothman specification # 43-TMSS-01 with the following
Contact Person Email ID - conditions:
Abdulmajeed.alothman@hitachienergy.
com WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. CBGWC2020.02 dated
February 04, 2020 shall be applicable for the
equipment to be supplied to SEC/National Grid SA.
NEW WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of project award)
and from the date of delivery for the direct
material supply order, as confirmed by the
manufacturer vide letter # Nil, dated May 01,
2017.
Total = 7
Website - http://www.bae-berlin.de/
FIAMM
ITALY
Website -
http://www.fiamm.com/index.aspx
GOULD (GNB)
United States
Website - http://www.goulds.com/
HOPPECKE Cell
GERMANY Up to 24 OPzS
Website - http://www.hoppecke.com/.
Website - http://www.tab.si/
Website - http://tungstonepower.com/
YUASA
JAPAN
Website -
http://www.yuasabatteries.com/
C&D
United States
Website - http://www.cdtechno.com/
EXIDE
United States
Website - http://www.exide.com/
Website - http://www.varta.com/
Total = 12
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #APEC
01/01/02 dated January 01, 2019.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order). as confirmed,
through their letter No. APEC2021010301 dated
03 January 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.
LEVER S.R.L. 125Vdc-400A Battery Charger type Based on S&SD letter# 16-03205-02-30504401
ITALY SME 125/400/SEC dated May 08, 2016, it is prequalified for
125Vdc-400A Battery Charger type
Plant -. SME 125/400/SEC as conforming to National Grid
SA Material Specification 46-TMSS-02 with the
Viale del Lavoro , 17-37024 Arbizzano following conditions:
(VR), Italy
•Ten (10) years extended warranty from the date
Contact Person - Mr. Llamettin of PAC of first Project in case of contract award
Canimoglu ,Sales Manager or from the date of delivery for the direct material
Email ID - pedcoltd@pedco.com.sa supply order and shall be subsequently reduced
Contact Person Email ID - yearly in case of future project, as confirmed by
i.canimoglu@pedco.com.sa the manufacturer through letter#
GG/nm/28042016 dated 28-04-2016.
AEG POWER SOLUTIONS SAS Originally was SAFT Power System SAS-France
FRANCE
BORRI S.P.A M/s Abunayyan Trading Type/Model - RTB.e The type test have PQ Letter:
ITALY P.O. box 321, Riyadh been conducted on S&SD Letter # 14-03226-01-030504401 dated
11411 Input 400 Vac 125 Vdc, 300 A June 4, 2014, pre-qualified for Battery Charger
Plant -Bibbiena(Arezzo) Italy Fax : +966 11 4764684 Output 125 Vdc battery charger at (125VDC, Type RTB.e).
Website : CETACE
Bossir S.P,A Via 8 Marzo. 2-52010 - www.abunayyangroup. Laboratories, 50018 WARRANTY:
Soci-Bibbiena, Italy com Scandicci (FI) – Italy Ten (10) years extended warranty/guarantee in
+966 11 4779111 from 18/03/2014 to respect of defects due to design, manufacture,
Contact Person - Mr.Paolo como 19/03/2014. Test installation & workmanship from the date of
Phone - +39-0575-5351 Report No. Provisional Acceptance Certificate (PAC) of the
Email ID - info@borri.it TRP _064_14, Date: first turnkey project in case of contract award or
19/03/2014. date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through letter # Nil, dated May 23,
2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by Braga Moro- Italy through
their letter # SEC Prequalification dated April 13,
2011.
C&D
United States
Website - http://www.cdtechno.com/
ERSKINE
United Kingdom
Website -
http://www.erskine-systems.co.uk/
EXIDE
United States
Website - http://www.exide.com/
Website - http://www.gutor.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated June
17, 2011.
Chloride S.A.S Project Execution Previously "AEES ", the name has been changed
FRANCE Development Co. Ltd to Emerson Network Power Industrial Systems -
(PEDCO) France based on Emerson Network Power
Plant -Previously AEES & Emerson 011 4648970, 2312462, Industrial Systems letter # nil dated 12/04/2013.
Network Power Industrial System 4169319 Then, the name has been changed again to
S.A.S Mr. Ilamettin Canimoglu, VERTIV Industrial Systems S.A.S based on
pedco@pedco.com.sa VERTIV Industrial Systems S.A.S letter # nil dated
Lyon , France 29/06/2017.
Lyon
Website -
http://www.emisa.es/web/index.asp?l
ang=ing
Total = 16
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #APEC
01/01/02 dated January 01, 2019.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order). as confirmed,
through their letter No. APEC2021010301 dated
03 January 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by Braga Moro- Italy through
their letter # SEC
Preq. dated April 13, 2011.
Website - http://www.gutor.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated June
17, 2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer
Statron AG through their letter # bm dated August
13, 2012.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
HUAWEI TECHNOLOGIES CO.LTD. Huawei Technologies UPS 2000 & UPS 5000 (A&E) Type tests were PQ Letter
CHINA Investment Saudi Arabia conducted from 12 – Based on S&SD letter # 18-02334-03-30504401
Ltd. Co. 16 February 2017 at dated November 15, 2018, HUAWEI Technologies
Bantian, Longgang District, Shenzhen, Prince Mohammed Bin China Co. Ltd. - China is pre-qualified for Uninterrupted
P. R. China Postal Code : 518129 Abdulaziz Street (Tahliah Telecommunication Power Supply (UPS 2000 & UPS 5000) Used in
St.) Olaya – Riyadh Technology Telecom / Data Centers as conforming to National
Contact Person - Mr. Ryan Liu C-Center. P.O. Box Laboratory (CTTL) in Grid SA specification # 46-TMSS-03, with the
Phone - +966 507981437 295320, Riyadh 11351 Baoding, Beijing, following conditions:
Email ID - Liuyong31@huawei.com +966 507981437 China and following
Mr. Ryan Liu; test reports have Warranty
Liuyong31@huawei.com been issued vide: Ten (10) years extended warranty/guaranty
1) KEMA from the date of (PAC) of the Turnkey project (In
Inspection Report case of contract award) and from the date of
No. 1127-7 for delivery for the direct material supply order. The
Huawei UPS 5000 guarantee/warranty shall be applicable from first
(A&E), project and shall cover all the cost of material and
2) SGS Inspection labor as per warranty/guarantee of material and
Report No. IN-SUZ- workmanship and will be subsequently reduced
5802-17009 for the yearly in case of future project award. This was
type testing of confirmed in writing by HUAWEI Technologies Co.
Huawei UPS 5000 Ltd. - China through their letter #
(A&E). 18102402-Mrk-SEC/F dated October 25th, 2018.
Total = 8
FIAMM
ITALY
Website -
http://www.fiamm.com/index.aspx
HOPPECKE Cell
GERMANY 260SP.HC2730
Website - http://www.hoppecke.com/.
AEG POWER SOLUTIONS SAS Originally was SAFT Power System SAS-France
FRANCE
C&D
United States
Website - http://www.cdtechno.com/
Website -
http://www.chloridepower.com
GNB
United States
HAWKER LTD
United Kingdom
Website - http://www.hawker.co.uk
SAB
GERMANY
Website - http://www.sab.com/
SEC
United States
Website - http://www.sec.gov/
VARTA
GERMANY
Website - http://www.varta.com/
YUASA EXIDE
United States
Website -
http://www.yuasabatteries.com/
Total = 11
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter #APEC
01/01/02 dated January 01, 2019.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order). as confirmed,
through their letter No. APEC2021010301 dated
03 January 2021, shall be applicable for the
equipment to be supplied to SEC/National Grid SA.
AEG POWER SOLUTIONS SAS originally was SAFT Power System SAS-France
FRANCE
BRAGA MORO Itea International Ltd Type / Model: BATTERY CHARGER, Prequalified for BATTERY CHARGER, 48 VDC
ITALY 21st Floor - Tamkeen (For Telecom Applications) (For Telecom Applications).
Tower, Al Yasmin -
Plant -Milan , Italy Riyadh 13325 - KSA Rating: 48V DC
Phone: 011 4207555
Via Canzo 4 20068 Peschiera Fax: 011 4655305
Borromeo, Milano, Milan ,Italy
Mr. Nabeel Huda; Mr.
Email ID - Edoardo Lando
montaser.suliman@bragamoro.com; +966550051979;
andrea.passanisi@bragamoro.com. +966506273359
Website - http://www.bragamoro.com/ nabeel@iteaint.com;
elando@iteaint.com
CONDITION:
All type, design, special & routine tests as per
SEC specifications/standards shall be carried out
on the first batch to be supplied to SEC in
securing an order in the manufacturer's
laboratory in the presence of three (3) SEC
engineers & one (1) approved independent
inspection agency Inspector as confirmed by the
manufacturer through their letter no. nil, dt:
05/02/2009.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no. nil, dt: 05/02/2009..
Website - http://www.exide.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer
Statron AG through their letter # bm dated August
13, 2012.
COM 10 INTERNATIONAL PTY. LTD. Type / Model: SWITCH MODE SWITCH MODE RECTIFIERS / BATTERY
AUSTRALIA RECTIFIERS / BATTERY CHARGERS CHARGERS ONLY FOR TELECOM APPLICATION.
ONLY FOR TELECOM APPLICATION.
Alpha , Australia
Website - http://www.force10.com.au/
Lyon
Website -
http://www.emisa.es/web/index.asp?l
ang=ing
Website -
http://www.harmerandsimmons.com/
T.D.I Type / Model: SWITCH MODE SWITCH MODE RECTIFIERS ONLY FOR TELECOM
United States RECTIFIERS ONLY FOR TELECOM APPLICATIONS
APPLICATIONS
Website - http://www.tdipower.com/
Total = 12
EXIDE
United States
Website - http://www.exide.com/
GNB
United States
Website - http://www.varta.com/
Chloride S.A.S Project Execution Previously "CHOLORIDE ", the name has been
FRANCE Development Co. Ltd changed to Emerson Network Power Industrial
(PEDCO) Systems - France based on Emerson Network
Plant -Previously AEES & Emerson 011 4648970, 2312462, Power Industrial Systems letter # nill dated
Network Power Industrial System 4169319 12/04/2013.
S.A.S Mr. Ilamettin Canimoglu, Then, the name has been changed again to
pedco@pedco.com.sa VERTIV Industrial Systems S.A.S based on
Lyon , France VERTIV Industrial Systems S.A.S letter # nill
dated 29/06/2017.
Lyon
ALCAD
SWEDEN
EMISA
SPAIN
Website -
http://www.emisa.es/web/index.asp
lang=ing
Website - http://www.friwo.de/
WARRANTY:
Seven (07) years extended warranty/guarantee
in respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.nil, dt: 9th June, 2008..
SAFT AB •Type: SBLE up to 1660AH (updated) Cell Type SBLE have SUSPENDED for all SEC/National Grid SA ongoing
SWEDEN •Type: SBM up to 1390AH been tested for and forthcoming projects based on VP,
•Type: SBH up to 920AH 1660 AH max. at Engineering letter # 20-01984-030504401 dated
Plant -Oskarshamn/ Sweden SAFT AB on Feb. December 02, 2020.
20, 2015. Report No.
Saft Ab, Jungnergatan,P.O. Box 709, REP 0927 Based on S&SD letter # 15-05875-30504401
Se-572 28 Oskarshamn Sweden dated September 17, 2015, the prequalification of
the manufacturer is updated for NICKEL
Contact Person - Mr. Stefhan Nomrén CADMIUM (NiCd) BATTERY .
Email ID -
stefhan.nomren@saftbatteries.com Previously " SAFT-NIFE, Sweden", the name has
Website - been changed to SAFT AB, Sweden, based on
http://www.saftbatteries.com/ SAFT AB Letter #Nil dated January 25, 2016.
Total = 9
BRAGA MORO Itea International Ltd Type / Model: The type test PQ Letter:
ITALY 21st Floor - Tamkeen MDCCT conducted for Prequalified for DC-DC Converters, 48 Volts
Tower, Al Yasmin - MDCCT BM 48V, 30 based on S&SD Letter 15-11268-01-30504401
Plant -Milan , Italy Riyadh 13325 - KSA A, 1+1 at Tecnolab dated January 13, 2016.
Phone: 011 4207555 in Verbania, Italy
Via Canzo 4 20068 Peschiera Fax: 011 4655305 Rating: 48 Vdc Output from March 24 – 28, WARRANTY:
Borromeo, Milano, Milan ,Italy 2014. Ten (10) years Extended Guarantee / Warranty
Mr. Nabeel Huda; Mr. from the
Email ID - Edoardo Lando date of PAC of first Project (in case of contract
montaser.suliman@bragamoro.com; +966550051979; award) or from
andrea.passanisi@bragamoro.com. +966506273359 the date of delivery for the direct material supply
Website - http://www.bragamoro.com/ nabeel@iteaint.com; order. This was confirmed, through their Letter #
elando@iteaint.com SEC Preq. dated April 13, 2011.
Total = 1
SIEMENS CANADA LIMITED RSG 2100, RSG2488 RX1500 for SAS Type test were “SEC/National Grid SA has decided to accept
CANADA witnessed during RUGGEDCOM Ethernet Switches and Routers
19th to 26th from SIEMENS CANADA LIMITED for 6 months
I Ia Sc Ci Rc 300 Applewood Crescent Novmebr 2014.Test only on exceptional basis till the end of July 2021"
Concord On, L4K 5C7 Laboratories Ultra
Tech Oakville
Contact Person - Mr. Mudassar Ahmed Canada and CRiQ PQ Lettter:
Regional Sales Manager Montreal Canada Based on S&SD letter# 15-07416-030504401
Phone - +905-856-5288 Letter Report No. dated October 28, 2015, it is pre-qualified for
Email ID - 3629159WT-03& 04 RUGGEDCOM Ethernet Switches and Routers
Mudasar.ahmed@siemens.com type RSG 2100, RSG 2488, RX 1500 for SAS as
Website - http://www.siemens.ca conforming to National Grid SA specification #
47-TMSS-01, with the following conditions:
WARRANTY:
Ten (10) years Extended Warranty shall be
applicable for the RUGGEDCOM Ethernet
Switches and Routers type RSG 2100, RSG
2488, RX 1500 for SAS, to be supplied
toSEC/National Grid SA as confirmed through
Letter # Nil dated 26.08.2014.
SCHWEITZER ENGINEERING Ahmad Alanezi - Ethernet Switches type SEL 2730M Test conducted at PQ Letter:
LABORATORIES, INC (SEL) Business Development KEMA Laboratories,
United States Manager & Saad Bin Netherlands. Test Based on S&SD letter # 17-04021/02-30504401
Nawaz - Sales Account Report # dated May 28, 2017, SCHWEITZER ENGINEERING
SCHWEITZER ENGINEERING Manager 1172860831, LABORATORIES, INC (SEL), USA is pre-qualified
LABORATORIES, INC 2350 NE Hopkins +996556866625 1172860827, for Ethernet Switches type SEL 2730M as
Court, Pullman, WA 99163 - USA ahmad_alanezi@selinc.c 117286O828 conforming to National Grid SA specification #
om 47-TMSS-01 with the following conditions:
Pullman Saad_Bin_nawaz@selin
c.com
Phone - +1.509.332.1890 WARRANTY:
Email ID - info@selinc.com
Website - www.selinc.com Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter # NIL dated July 16, 2015.
BELDEN / HIRSCHMANN AUTOMATION MAR 1030 (MAR 1030, MAR 1032, All the type tests PQ Letter
AND CONTROL GMBH MAR 1130, MAR 1132) / AFS 675 were conducted in Based on S&SD Letter # 16-07249/02-30504401
GERMANY Series Phoenix test lab and dated 28th Nov 2016, it is pre-qualified
MAR 1040 (MAR 1040, MAR 1042, Hirschmann test lab
Plant -Plant Stuttgart, 72654, MAR 1140, MAR 1142) / AFS677 / during 14th April WARRANTY:
Neckartenzlingen, Germany AFR677 Series 2016 to 06th July Ten (10) years warranty shall be applicable for
RSP 35 / AFS 665 / RSP 30 Series 2016. the models of Ethernet Switches and Routers to
Contact Person - Joy Banerji , Vertical RSR 30 / AFS655 Series be supplied to SEC/National Grid SA as confirmed
Account Manager - O&G and Power , through Letter #Nil dated 20.03.2015.. This has
Belden been confirmed in writing by the manufacturer;
Contact Person Email ID - through letter # AIL/BRD/ SEC/PQ/19 dated 22nd
joy.banerji@Belden.com May 2010
Website -
http://www.beldensolutions.com/
Total = 3
SIEMENS CANADA LIMITED RSG2100 RX1500 for metering System. Type test were “SEC/National Grid SA has decided to accept
CANADA witnessed during RUGGEDCOM Ethernet Switches and Routers
19th to 26th from SIEMENS CANADA LIMITED for 6 months
I Ia Sc Ci Rc 300 Applewood Crescent Novmebr 2014.Test only on exceptional basis till the end of July 2021"
Concord On, L4K 5C7 Laboratories Ultra
Tech Oakville
Contact Person - Mr. Mudassar Ahmed Canada and CRiQ PQ Lettter:
Regional Sales Manager Montreal Canada Based on S&SD letter# 15-07416-030504401
Phone - +905-856-5288 Letter Report No. dated October 28, 2015, it is pre-qualified for
Email ID - 3629159WT-03& 04 RUGGEDCOM Ethernet Switches and Routers
Mudasar.ahmed@siemens.com type RSG 2100, RX 1500 for Metering System as
Website - http://www.siemens.ca conforming to National Grid SA specification #
47-TMSS-02, with the following conditions:
WARRANTY:
Ten (10) years Extended Warranty shall be
applicable for the RUGGEDCOM Ethernet
Switches and Routers type RSG 2100, RX 1500
for Metering System, to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 26.08.2014.
BELDEN / HIRSCHMANN AUTOMATION (MAR 1030, MAR 1032, MAR 1130, PQ Letter
AND CONTROL GMBH MAR 1132) / AFS 675 Series) Based on S&SD letter #21-01179-030504401
GERMANY dated November 02, 2021, the manufacturer is
prequalified for INDUSTRIAL ETHERNET SWITCH
Plant -Plant Stuttgart, 72654, FOR ADVANCED METERING INFRASTRUCTURE
Neckartenzlingen, Germany (AMI) as conforming to National Grid SA
specification #47-TMSS-02, with the following
Contact Person - Joy Banerji , Vertical conditions:
Account Manager - O&G and Power ,
Belden WARRANTY
Contact Person Email ID - Ten (10) years extended warranty from the date
joy.banerji@Belden.com of PAC of the first turnkey project (in case of
Website - contract award) or date of first delivery (in case
http://www.beldensolutions.com/ of direct material supply order), as confirmed,
through their Letter # Nil dated September 12,
2021 shall be applicable for the equipment to be
supplied to SEC/National Grid SA.
Total = 3
Website -
http://www.masskablo.com/about us
company.asp?md=7
STEINER
GERMANY
Website -
http://www.steiner-binoculars.com/ind
ex.html
RIYADH CABLES
Saudi Arabia
Plant -Riyadh
SAUDI CABLE
Saudi Arabia
Jeddah
Website -
http://www.mesccables.com/
Plant -jeddah
jeddah
LS CABLES Previously LG
SOUTH KOREA
Plant -Gumi/Korea
Taihan Cable & Solution Co. Ltd. Taihan Cable & Solution Rating - 500 V Test Date - Aug KTC Korea testing Certification
KOREA, Republic of Co., Ltd. Branch 2011
P. O. Box 300201,
Plant -Dangjin Factory Riyadh 11372, Office No.
18, Commercial Complex
317, Simin Daero, Dongan-gu Building, King Abdulaziz
Rd. Exit 5, Kingdom of
Anyang-si Saudi Arabia.
+966 11 410 1773
Contact Person - Jang Hee Lee hslee0822@taihan.com
Phone - +82 2 316 9190
Email ID - janghee@taihan.com
Contact Person Email ID -
janghee@taihan.com
Website - www.taihan.com
Total = 11
ALCATEL
SWEDEN
Website - http://www.alcatel.se/
B.V.TWENTSCHE KABELFABRIEK
NETHERLANDS
Website - http://www.tkf.nl/
BICC
United Kingdom
Website -
http://www.generalcable.com/General
Cable/
BRUGG TELECOM AG
SWITZERLAND
Website - http://www.brugg.com/
CORNING CABLES
United Kingdom
Website -
http://www.corningcablesystems.com/
FUJIKURA LTD.
JAPAN
FURUKAWA
JAPAN
Website -
http://www.furukawa.co.jp/english/ind
ex.htm
MIDDLE EAST OPTIC FIBER & CABLE 96 F G.652D Duct Type NMFOC Type Tests
MANUFACTURING CO. (MEFC) conducted at UL
Saudi Arabia Abu Dhabi, UAE
(Test Report No.
Riyadh , Saudi Arabia 4789725319-1 dated
31.12.2020)
Website - http://www.mefcf.com/
Type Test Report No.
QC.96 dated
07.01.2021
Website - http://www.nkf.nl/
CONDITION:
The first batch of each type of Non Metallic Fiber
Optic Cable to be supplied to SEC shall be type
tested per relevant International and SEC
Specifications in presence of three (3) SEC
Engineers and one (1) SEC approved IIA
Inspector and all cost pertaining to the test shall
be borne by the Manufacturer as confirmed
through Letter# Nil dated September 12, 2009.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.EU.SEC.PQ.01, dt: 17th June, 2009..
SUMITOMO
JAPAN
Yokohama
Website - http://www.sei.co.jp/
HITACHI
JAPAN
SIEMENS
GERMANY
LS PREVIOUSLY LG
SOUTH KOREA
Website - http://www.lscable.com/
SM 96F G.652D-
Duct Type, Report #
4789721350-3, R2,
Testing Dates:
14-12-2020 to
10-02-2021 and
date of issue:
01-3-2021.
Third Party
Independent
Inspector Intertek
Report # IR03Rev03
dated: 16-02-2021.
Website -
http://www.mesccables.com/
PIRELLI
ITALY
Website - http://www.afltele.com/
PRYSMIAN TELECOM Zamil Group Holding co, Model: Test Performed at PREVIOUSLY "PIRELLI"
SPAIN Commerical Div Kinectrics Canada in
6728, 48 Cores , May, 2014
Plant -Vilanova I La Geltru/Spain Report#
K-419533-RC-0003-
Ctra. C-15,Km, 2-P.I. Masia D’En Notari R01
08800 Vilanova I La Geltru ( Spain)
DRAKA NK
FINLAND
Website - http://www.draka.com/
Total = 23
Plant -Sweden
Ludvika, Sweden
PHILIPS
NETHERLANDS
Website -
http://www.philips.nl/index.page
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt:mar 15, 2013.
TELETTRA
FRANCE
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Nil dated June 18, 2014.
FUJITSU
JAPAN
Ontario, Canada
PQ Lettter
Based on TADD letter# 09-0297-030225 dated
28th March 2009; (Note: GE Industrial System,
Canada has bought only the Lentronics business
from Nortel, Canada that manufactures TN1U
SHD Fiber Optic Terminal Equipment and MUX)
NORTEL ON HOLD
CANADA
Website - http://www.nortel.com/
ALCATEL
FRANCE
Website - http://www.alcatel.fr/
Hitachi Energy Switzerland Ltd. Hitachi Energy FOX515 Access Multiplexer KEMA Inspection Mfr. Name change from ABB Switzerland Ltd. to
SWITZERLAND Hitachi Energy Ltd. Report reference Hitachi Energy Switzerland Ltd.
Riyadh, Saudi Arabia No. 1119-17
Plant -switzerland Based on TADD letter# 09-0576-030225 dated
FOX615 Access Multiplexer (With June 10, 2009, SCADA letter# SOCW/ DIV/97 and
Bruggerstrasse 72, 5400 Baden OPIC1 Card) Telecommunication Dep. letter#
09-136-03040001. ABB, Switzerland is
Contact Person - Mr. Ahmed Abubasha, pre-qualified for FOX515 Access Multiplexer.
Mr. Abdulmajeed Alothman
Phone - +41 58 588 33 50
Email ID - Based on S&SD letter # 17-04894-01-30504401
Ahmed.abubasha@hitachienergy.com, dated July 18, 2017, ABB, Switzerland is
abdulmajeed.alothman@hitachienergy.c pre-qualified for FOX615 Access Multiplexer
om (With OPIC1 Card) as conforming to National Grid
Contact Person Email ID - SA specification # 48-TMSS-06, with the
Ahmed.abubasha@hitachienergy.com, following conditions:
abdulmajeed.alothman@hitachienergy.c
om WARRANTY:
Website - www.hitachienergy.com •Ten (10) years extended warranty/Guarantee
from the date of PAC as confirmed; through their
Letter No. 16-05762-01-030504401 dated
27/07/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.
Total = 11
Huawei Technologies Co., Ltd. Huawei Tech. Investment OSN 550 Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. OSN 580 (Global Compliance Based on S&SD letter# MPQ # 35489820 dated
Huawei Technologies Testing Center) May 28, 2019, the manufacturer is prequalified
Plant -Sonshan, Dongguan Investment Saudi Arabia Model E6600 series ( E6608, E6608T, Address NO.2 New for MEDIUM DENSITY FIBER OPTICS SYSTEM
Ltd. Co. E6616) City Avenue Song (FIBER OPTIC LOW DENSITY Equipment) as
Huawei - Song Shan Hu Technology Prince Mohammed Bin Shan Lake Sci. confirming to National Grid SA specification #
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah &Tech. Industry 48-TMSS-06, with the following conditions:
St.) Olaya – Riyadh Park, Dongguan,
Contact Person - Liu Yong C-Center. P.O. Box Guangdong, P.R.C. WARRANTY
Phone - 0507981437 295320, Riyadh 11351 Test Date Ten (10) years extended warranty from the date
Email ID - Liuyong31@huawei.com +966 507981437 03.04.2019 – of PAC of the first turnkey project (in case of
Website - huawei.com Liuyong31@huawei.com 11.04.2019 contract award) or from date of first delivery (in
case of direct material supply order), as
confirmed, vide Huawei Letter No. Nil dated
01/08/2018 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.
WARRANTY
Ten (10) years extended warranty/guarantee for
the offered DVM Model OSN 580 in respect of
defects due to design, manufacture, installation &
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project in case of contract award or date of
delivery in case of direct material supply order,
as confirmed vide Huawei Technologies Co., Ltd.
letter No. NIL Dated 01 August 2018
PQ Letter:
Based on S&SD letter #22-00370-30504401
dated March 23, 2022 the manufacturer is
prequalified for MEDIUM DENSITY FIBER OPTICS
SYSTEM (FIBER OPTIC LOW DENSITY EQPT.), as
conforming to National Grid SA specification
#48-TMSS-06, with the following conditions:
WARRANTY:
Ten (10) years Extended Warranty as confirmed
through Letter #Nil dated 19/05/2021 shall be
applicable for all supplies to the Company by
Huawei Technologies Co., Ltd. - China
Turgi , France
Website - http://www.abb.fr/
LICOM
United States
Website - http://www.licom.net/
PRISM ON HOLD
CANADA
SIEMENS
GERMANY
Total = 5
Total = 2
ZTE Corporation Landis + Gyr AG- ZXONE 9700 ZTE Corporation - PQ letter:
CHINA Greece China has Based on S&SD letter # MPQ 11819920-classI(a)
3rd floor, Tawaren successfully -2016-class I(b) dated November 08, 2017, ZTE
Plant -LiuXian Rd Xili Shenzhen China Center Building King completed the type Corporation - China is pre-qualified for DWDM as
PRC Fahad Road tests of DWDM conforming to latest National Grid SA
P.O.BOX#58970 Riyadh, Equipment at China specification # 48-TMSS-08
LiuXian Rd Xili Shenzhen China PRC Saudi Arabia Telecommunication
+966 539467479 Technology Labs WARRANTY:
Shenzhen yang.shuai130@zte.com (CTTL). Bearing • Ten (10) years extended warranty/guarantee in
.cn report # B17X60154 respect of defects due to design, manufacture,
Contact Person - Eng. Fox Yang & B17X20741 during installation and workmanship from the date of
Phone - +966 539467479 August 14-26, 2017 Provisional Acceptance Certificate (PAC) of the
Email ID - yang.shuai130@zte.com.cn; in the presence of first turnkey project in case of contract award or
zhou.rong35@zte.com.cn; SEC/National Grid date of first delivery in case of direct material
ou.rong@zte.com.cn SA Engineers and supply order, as confirmed by the manufacturer
Contact Person Email ID - SGS inspector vide letter # ZTE-20170402-SECDWDM-01, dated
yang.shuai130@zte.com.cn bearing report March 03, 2017.
Website - www.landisgyr.com #IN-SZ-5802-17082-
1&
IN-SZ-5802-17082-2
.
ALCATEL-LUCENT AlCatel Lucent Type 1830 PSS-32 Type tested during PQ Lettter
ITALY Riyadh 20th -31st October Based on S&SD letter # 15-0010-02-30504401
2014 and 4, 27-28 dated 12th February 2015, the manufacturer is
Trieste, Italy Nov, 2014. prequalified for OTN-DWDM equipment Type 1830
PSS-32 as conforming to National Grid SA
Contact Person - Mr. Eric Saniard, Test Report Nos: specification # 48-TMSS-08, Rev.0 with the
Account Sale Manager 80SO00094, following condition:
Email ID - 80SO00096, CSi
eric.es.saniard@alcatel-lucent.com Test Report WARRANTY
No.0118/ME/CMP/14 Ten (10) years extended warranty/guarantee in
Rev.2, respect of defects due to design, manufacture,
Centrotecnica SRL installation & workmanship from the date of
report No. Provisional Acceptance Certificate (PAC) of the
VR1400223IMRK.do first turnkey project in case of contract award or
c. date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 6th june, 2014.
HUAWEI TECHNOLOGIES CO.LTD. Huawei Technologies Optix OSN 8800 Type tests were PQ Letter:
CHINA Investment Saudi Arabia OptiX OSN 9800 series (OSN 9800 conducted from 20 Based on S&SD letter # 18-07410-03-30504401
Ltd. Co. M12, OSN 9800 M24, OSN 9800 M05 to 29 January 2016 dated November 15, 2018, & S&SD letter
Bantian, Longgang District, Shenzhen, Prince Mohammed Bin and OSN 9800 Universal Platform at Huawei #21-00071/01-030504401 dated February 16,
P. R. China Postal Code : 518129 Abdulaziz Street (Tahliah Sub-rack) Technologies Co. Ltd 2021, HUAWEI Technologies Co. Ltd. - China is
St.) Olaya – Riyadh at Shenzhen, China pre-qualified for OTN-DWDM Equipment as
Contact Person - Mr. Ryan Liu C-Center. P.O. Box and from 21 – 22 conforming to National Grid SA specification #
Phone - +966 507981437 295320, Riyadh 11351 November 2016 at 48-TMSS-08, with the following conditions:
Email ID - Liuyong31@huawei.com +966 507981437 Mr. China
Ryan Liu Telecommunication Warranty:
Liuyong31@huawei.com Technology Ten (10) years extended warranty/guaranty
Laboratory (CTTL) in from the date of (PAC) of the Turnkey project (In
Baoding, China. The case of contract award) and from the date of
following test delivery for the direct material supply order. The
reports have been guaranty/warranty shall be applicable from first
issued vide: project and shall cover all the cost of material and
KEMA Inspection labor as per warranty/guaranty of material and
Report No. DNV- GL workmanship and will be subsequently reduced
1067-16 for Huawei yearly in case of future project award. This has
OTN-DWDM been confirmed in writing by HUAWEI
Equipment and Technologies Co. Ltd. - China through their letter
SGS Inspection Ref. 18102408-Mrk-SEC/F dated October 25,
Report No. 2018 & Letter # AJC/PQ-GW dated 31 December
IN-SUZ-5802-16066 2020.
for the type testing
of Huawei
OTN-DWDM
Equipment.
Total = 4
Japan-Tokyo
ALCATEL-LUCENT PQ Lettter
CHINA Based on S&SD letter # 14-07395-30504401,
dated 23/10/2014, the test facility of Alcatel
Shanghai China Lucent in (Bydgoszcz, Poland) is allowed to
conduct Factory Routine test and Integration
testing of communication equipment
manufactured in Alcatel-Lucent Factory in
Shanghai China confirming to National Grid SA
requirements.
CONDITION
Based on TS&SD letter #10-03519/03-03032301
dated 17/04/2011, it is pre-qualified for Fiber
Optic Communication Terminal type
Optenix1660SM with the following conditions:
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # ALU/172/SI/2010 dated 12/12/2010.
CONDITION
Type, Special, sample & routine tests shall be
conducted on the first batch of 1511MAX Series
to be supplied to SEC, in the presence of three
(3) SEC Engineers & one (1) SEC approved
independent inspection agency Inspector in an
independent testing laboratory. All the related
costs for witnessing the tests will be borne by
the manufacturer. This was confirmed by Alcatel
Lucent (ASB) Shanghai China through response
letter # ALU/25/SI/2011 dated 30/01/2011 and
letter # Nil dated 27/04/2011.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 30/01/2011.
manufacturer.
Total = 4
Website - http://www.nokia.com/
WARRANTY:
Seven (7) years extended warranty from the
date of PAC of the turnkey project in case of
contract award or date of delivery in case of
direct material supply order. This was confirmed
by Amwaj Telecom MFG. Co. letter dated
09/06/2010.
Website -
http://www.corningcablesystems.com/
Website - http://www.ericson.com/
OPTOKON Tarasol Technology for 1. OFMR for Telecom 450 mm x 900 mm PQ Lettter
CZECH REPUBLIC Telecom & IT x 2200 mm OFMR for SAS 800 mm x Based on TS&SD letter# 06-F208-03032300
Bashar Mohammad 800 mm x 2200mm OFMR 16U dated Feb 21, 2006, it is prequalified only for the
Jihlava , Czech Republic Nawar Said specified accessories
+966 11 4765284; +966 2. Rack Mount Fiber Optic Patch
Website - http://www.optokon.cz/ 503522458 Panel/FSTP type MCNP & MFDC (TMVJ
bashar@tarasoltech.co & OFDU) consisting of 12/24/36/48/96
m; ports.
nawar@tarasoltech.com
3. Fiber Optic Wall Mount Box type of
MPIC consisting of 12/24/36/48/96
ports
WARRANTY:
Five (5) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Nil, dt: June 10, 2013.
TELECT PQ Lettter
Poland Based on TS&SD letter# 09-01095-03032301
dated 18th. April 2009 for the following
Wroclaw , Poland accessories:
- Management Rack E-9000 series
- Distribution & Termination Unit LCX.
- Wall mounted unit LanLinxs.
INDUSTRIAS ARRUTI
SPAIN
Website -
http://www.grupoarruti.com/empresa.a
sp
JIANGSU ZHONGTIAN TECHNOLOGY OPGW Joint Box, Type ST up to 192 Tests performed at: PQ Letter
CO.LTD (ZTT) splices China Based on S&SD Letter # 17-02628-01-30504401
CHINA Telecommunication dated May 09, 2017it is prequalified with the
Technology Labs following condition:
Chinanantong, China (January 09-13,
2017) WARRANTY:
Report # B17X70084 Ten (10) years extended warranty from the date
of PAC of the first turnkey in case of contract
award or date of first delivery in case of direct
material supply order as confirmed through ZTT
letter # ZTT-G-2016-06-10-01 dated 10/6/2016.
AFL TELECOMMUNICATIONS GMBH OPGW Joint Box Previously Draka Comteq Germany GmbH & KG.
GERMANY
WARRANTY:
Monchengladbach , Germany Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Total = 12
ALCATEL NV
FRANCE
Website - http://www.mitel.com/
Website -
http://www.northerntelecom.com/
PHILIPS
NETHERLANDS
Website -
http://www.philips.nl/index.page
RAYCHEM
United States
United States-Ca
NORTEL ON HOLD
CANADA
Website - http://www.nortel.com/
ERICSON
SWEDEN
Website - http://www.ericson.com/
SIEMENS
GERMANY
AT & T
United States
Website - http://www.att.com/
ALCATEL
FRANCE
Website - http://www.alcatel.fr/
Total = 10
Ljubljana WARRANTY
•Ten (10) years extended warranty in respect of
the defects due to manufacturing and
workmanship, from the date of PAC of the first
turnkey project (in case of contract award) or
date of first delivery (in case of direct material
supply order), as confirmed through their Letter
No. DTE349/14-KIP dated September 05,2014
shall be applicable.
BARCELONA PQ Lettter
Based on TS&SD Letters# 09-01439-2-03032301
Contact Person - Marco Sensei dated 7th July 2009 & 10-00845-1-03032301
Phone - +34 944 522 003 dated April 04, 2010. It is pre- qualified for
Email ID - Tele-protection Equipment type TPU-1 with the
marco.senesi@zivautomation.com following conditions:
Contact Person Email ID -
marco.senesi@zivautomation.com WARRANTY
Website - www.zivautomation.com Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
GE/ALSTOM POWER CONVERSION Branch of COGELEX DIP5000 Previously Areva, the name has been changed to
FRANCE Alkhobar, GE/ Alstom power conversation
Firas.salman@ge.com
Plant -Ludres 0096638579071
Firas.salman@ge.com
418 Rue Denis Papin
54712 Ludres Cedex
Hitachi Energy Switzerland Ltd. Hitachi Energy Ltd NSD570 Name has changed from ABB Switzerland to
SWITZERLAND Riyadh, Saudi Arabia Hitachi Energy Switzerland Ltd
+966 11 2181703 Mobile:
Plant -switzerland +966 500414555
Total = 5
Huawei Technologies Co., Ltd. Huawei Tech. Investment S5720-52X-PWR-SI-AC; Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. (Global Compliance Based on S&SD letter # 19-00756-30504401
Huawei Technologies S5731, S5732 and S5735 Testing Center) dated June 20, 2019, the manufacturer is
Plant -Sonshan, Dongguan Investment Saudi Arabia Address NO.2 New prequalified for Ethernet Switch as confirming to
Ltd. Co. City Avenue Song National Grid SA specification # 48-TMSS-10,
Huawei - Song Shan Hu Technology Prince Mohammed Bin Shan Lake Sci. with the following conditions:
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah &Tech. Industry
St.) Olaya – Riyadh Park, Dongguan, WARRANTY
Contact Person - Liu Yong C-Center. P.O. Box Guangdong, P.R.C. Ten (10) years extended warranty from the date
Phone - 0507981437 295320, Riyadh 11351 Test Date 2017.4.19 of PAC of the first turnkey project (in case of
Email ID - Liuyong31@huawei.com +966 507981437 - 2017.4.24 contract award) or from date of first delivery (in
Website - huawei.com Liuyong31@huawei.com case of direct material supply order), as
confirmed, vide Huawei Letter No. Nill dated
14/10/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.
WARRANTY
Ten (10) years extended warranty/guarantee for
the offered Ethernet Switch with series S5731,
S5732 and S5735 in respect of defects due to
design, manufacture, installation & workmanship
from the date of Provisional Acceptance
Certificate (PAC) of the first turnkey project in
case of contract award or date of delivery in
case of direct material supply order, as
confirmed vide Huawei Technologies Co., Ltd.
letter No. NIL Dated 27 October 2020
MICROSENS GmbH & Co. KG 1. MS400890MX-BS, PLR, 25 Ports, Type Tests PQ Letter
GERMANY 54 VDC successfully Based on S&SD letter # #MPQ 11749219 dated
2. MS652119PM-BS, PLM, 13 Ports, completed at January 19, 2020, the manufacturer is
Plant -Germany 54 VDC PHOENIX – prequalified for Ethernet Switch as confirming to
3. MS650919PM-BS, PL+, 7 Ports, Germany, Test National Grid SA specification # 48-TMSS-10,
D-59067 Hamm 54 VDC report No. with the following conditions:
U190996E1 &
Contact Person - Mr. Dirk Herppich, E190996E1, and WARRANTY
Technical Consultant SGS report No. Ten (10) years extended warranty from the date
Phone - +492381/9452-0 P1Z80001. of PAC of the first turnkey project (in case of
Email ID - info@microsens.com contract award) or date of first delivery (in case
Contact Person Email ID - of direct material supply order), as confirmed,
DHerppich@microsens.de; through their Letter #Nil dated March 28, 2018,
YRezki@microsens.de shall be applicable for the equipment to be
Website - www.microsens.com supplied to SEC/National Grid SA.
Total = 2
Huawei Technologies Co., Ltd. Huawei Tech. Investment NE08E-S6 Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. (Global Compliance Based on S&SD letter# 19-00755-30504401
Huawei Technologies NE series ( 8000, 9000 and 40E series) Testing Center) dated June 20, 2019, the manufacturer is
Plant -Sonshan, Dongguan Investment Saudi Arabia Address NO.2 New prequalified for Communication Services Router
Ltd. Co. City Avenue Song as confirming to National Grid SA specification #
Huawei - Song Shan Hu Technology Prince Mohammed Bin Shan Lake Sci. 48-TMSS-11, with the following conditions:
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah &Tech. Industry
St.) Olaya – Riyadh Park, Dongguan, WARRANTY
Contact Person - Liu Yong C-Center. P.O. Box Guangdong, P.R.C. Ten (10) years extended warranty from the date
Phone - 0507981437 295320, Riyadh 11351 Test Date 2017.4.19 of PAC of the first turnkey project (in case of
Email ID - Liuyong31@huawei.com +966 507981437 - 2017.4.24 contract award) or from the date of first delivery
Website - huawei.com Liuyong31@huawei.com (in case of direct material supply order), as
confirmed, vide Huawei Letter No. Nill dated
14/10/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.
WARRANTY
Ten (10) years extended warranty/guarantee for
the offered Routers in respect of defects due to
design, manufacture, installation & workmanship
from the date of Provisional Acceptance
Certificate (PAC) of the first turnkey project in
case of contract award or date of delivery in
case of direct material supply order, as
confirmed vide Huawei Technologies Co., Ltd.
letter No. NIL Dated 27 October 2020 & letter No.
NIL Dated 18 January 2021
Total = 1
Huawei Technologies Co., Ltd. Mr. Ryan Liu Optix OSN 8800 Intelligent Optical July 02,2019, PQ Letter
CHINA +966 507981437 Transmission System; Model: OSN Huawei Global
Liuyong31@huawei.com 8800 Compliance & Based on S&SD letter# MPQ459820020-Class I(a)
Plant -Sonshan, Dongguan OptiX OSN 9800 series (OSN 9800 Testing Center, SGS -2018 dated August 04, 2019, & S&SD letter
M12, OSN 9800 M24, OSN 9800 M05 Test Report No. #21-00071/01-030504401 dated February 16,
Huawei - Song Shan Hu Technology and OSN 9800 Universal Platform IN-SUZ-5301-19012, 2021 the manufacturer is prequalified for
IndustrialPark NA dongguan China PRC Sub-rack) Shanghai, China. OPTICAL FIBER AMPLIFIER (OFA) DEVICES,
SUBSYSTEMS OR COMPONENTS as confirming
Contact Person - Liu Yong to National Grid SA specification # 48-TMSS-20
Phone - 0507981437 rev.00, with the following conditions:
Email ID - Liuyong31@huawei.com
Website - huawei.com WARRANTY
IPG PHOTONICS Al Salam Industrial & OSTP-DWDM Type Tests were PQ Lettter
United States Trdg Est Erbium Amplifier rack Mount(EAR) and conducted in VDE Based on S&SD letter # 15-05564-2-30504401
Head Office,PO Raman Amplifier Rack Mount(RAR) Germany in dated July 05, 2015, it is pre-qualified for supply,
50 Old Webster Road Oxford Ma01540 Box:17176 presence of three installation and configuration of Optical Service
T 508 373 1100 F 508.373.1101 Jeddah-21484 Saudi SEC/National Grid Transport Platform (OSTP-DWDM), Erbium
Arabia SA Engineers during Amplifier rack Mount (EAR) and Raman Amplifier
Contact Person - Mr. Mark Cannata Tel: +966 12 608 1028 8th to 19th Rack Mount (RAR) manufactured by IPG
Director & Marketing &Mr. Yasser Fax: +966 12 608 1035 December Photonics, Oxford, Massachusetts, USA plant as
Adnan Skik yasserad@electroi.com 2014.Three Failed conforming to National Grid SA specification #
Website - test (EMC Emission 48-TMSS-08 with following condition:
http://www.ipgphotonics.com of
Enclosure,Dielectric/I WARRANTY
nsulation Resistance Ten (10) years Extended Warranty as confirmed
and Mechanical through
Operation tests) IPG Letter # NIL dated 2nd April 2014 shall be
were repeated applicable for all supplies made to the Company
during 13th to 17th by IPG Photonics Oxford, Massachusetts, USA.
April 2015.Test Lab
RMS and Type Test
Report # MI-1220-4
dated 09-05-2011
IPG PHOTONICS Al Salam Industrial & OSTP-DWDM Type Tests were PQ Lettter
ITALY Trdg Est Erbium Amplifier rack Mount(EAR) and conducted in VDE Based on S&SD letter # 15-05564-3-30504401
Head Office,PO Raman Amplifier Rack Mount(RAR) Germany in dated July 05, 2015, it is pre-qualified for supply,
50 Old Webster Road Oxford Ma01540 Box:17176 presence of three installation and configuration of Optical Service
T 508 373 1100 F 508.373.1101 Jeddah-21484 Saudi SEC/National Grid Transport Platform (OSTP-DWDM), Erbium
Arabia SA Engineers during Amplifier rack Mount (EAR) and Raman Amplifier
Contact Person - Mr. Mark Cannata Tel: +966 12 608 1028 8th to 19th Rack Mount (RAR) manufactured by IPG
Director & Marketing &Mr. Yasser Fax: +966 12 608 1035 December Photonics, Milan Italy conforming to National Grid
Adnan Skik yasserad@electroi.com 2014.Three Failed SA specification # 48-TMSS-08 with following
Website - test (EMC Emission condition:
http://www.ipgphotonics.com of
Enclosure,Dielectric/I WARRANTY
nsulation Resistance Ten (10) years Extended Warranty as confirmed
and Mechanical through
Operation tests) IPG Letter # NIL dated 2nd April 2014 shall be
were repeated applicable for allSupplies made to the Company
during 13th to 17th by IPG Photonics Milan Italy.
April 2015. Type
Test
Report#MI-1220-4
dated 09-05-2011
Total = 3
Huawei Technologies Co., Ltd. Huawei Tech. Investment PTN990 Huawei GCTC PQ Letter
CHINA Saudi Arabia Co,. LTD. PTN 910 (Global Compliance Based on S&SD letter# MPQ 354920620 dated
Huawei Technologies PTN 7900-12 & Testing Center) May 28, 2019, the manufacturer is prequalified
Plant -Sonshan, Dongguan Investment Saudi Arabia PTN 990E Test Date for PACKET TRANSPORT SYSTEM BASED ON
Ltd. Co. 03.04.2019 – MPLS-TP as confirming to National Grid SA
Huawei - Song Shan Hu Technology Prince Mohammed Bin 11.04.2019 specification # 48-TMSS-21, with the following
IndustrialPark NA dongguan China PRC Abdulaziz Street (Tahliah conditions:
St.) Olaya – Riyadh
Contact Person - Liu Yong C-Center. P.O. Box WARRANTY
Phone - 0507981437 295320, Riyadh 11351 Ten (10) years extended warranty from the date
Email ID - Liuyong31@huawei.com +966 507981437 of PAC of the first turnkey project (in case of
Website - huawei.com Liuyong31@huawei.com contract award) or from the date of first delivery
(in case of direct material supply order), as
confirmed, vide Huawei Letter No. Nil dated
01/08/2018 which shall be applicable for the
equipment to be supplied to SEC/National Grid SA
WARRANTY
Ten (10) years extended warranty/guarantee for
the offered MPLS-TP model PTN 990E in respect
of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed vide Huawei Technologies
Co., Ltd. letter No. NIL Dated 27 October 2020
CORIANT GMBH Mr. Mohammad Ibrahim MPLS-TP models 7090-240 M-1 and Type Tests were PQ Letter
GERMANY MAlibrahim@infinera.co 7090-100 CEM successfully
m completed at Based on S&SD letter # MPQ456320620 dated
St. Martin Str. 76 81541 Munich PHOENIX, Germany - May 05, 2020, the manufacturer Infinera (Coriant)
Germany SGS Report is prequalified for PACKET TRANSPORT SYSTEM
#5142914#10, dated BASED ON MPLS-TP as confirming to National
Contact Person - Mr. Olaf Horsthemke 22 November 2019. Grid SA specification # 48-TMSS-21, with the
Managing Director following conditions:
Phone - +49-89-540215006
Email ID - • Manufacturer confirm that
Olaf.horsthemke@coriant.com manufactured/assembled and dispatched
equipments will be supplied from Coriant
GMBH/ML&S located in 17489 Greifswald,
Germany, as confirmed, through Letter #nill dated
#25.02.2020
WARRANTY
OTN Systems NV NESIC S.A. Co. LTD XT2210-A and XT2215-A Type Tests PQ Letter
BELGIUM NESIC SA successfully Based on S&SD letter # MPQ 460220620 dated
Mezzanine Flr. completed at January 21, 2020, the manufacturer OTN
Plant -Belgium Saudi Consolidated & Denayer – Belgium , Systems NV, Belgium is prequalified for PACKET
Contracting Bldg. Test report No. TRANSPORT SYSTEM BASED ON MPLS-TP as
Industrielaan 17b 2250 Olen 16B Cross Hafith Ibrahim PCC-CLI-5021, and confirming to National Grid SA specification #
Industrielaan Olen St. Type Test Report 48-TMSS-21, with the following conditions:
Al Khobar 34447 issued on October
Contact Person - Francis Baestaens; 17, 2019. WARRANTY
Khaled Abu Sharar Ten (10) years extended warranty from the date
Phone - +32 473653992; 0553581743 of PAC of the first turnkey project (in case of
Email ID - contract award) or date of first delivery (in case
francis.baestaens@otnsystems.com; of direct material supply order), as confirmed,
Khaled.AbuSharar@otnsystems.com through their Letter #MPQ460220620-Class I(b)
Website - http://www.otnsystems.com -2018 dated #March 11, 2020, shall be applicable
for the equipment to be supplied to SEC/National
Grid SA.
Total = 3
SIEMENS
United States
Website -
http://www.usa.siemens.com/entry/en/
ABB EJF
CZECH REPUBLIC
Website -
http://www.abb.com/substation-autom
ation
ELEQ B.V. Hamid Nazar Malik Up to 380 kV Type Test were PQ Lettter
GERMANY Contracting Co. Ltd ( Split core and continuous Ring type witnessed Based on S&SD letter# 15-10406-01-30504401,
HNCC) CTs successfully by dated
Zweigniederlassung Deutschland , Contact Person:Mr. umer SEC/ National Grid December 10, 2015. the manufacturer is
Karl-Ferdinand-Braun-Strabe 150170 Shaikh, P.O.Box 132631 SA engineers during prequalified for Split Core and Continuous Ring
Kerpen Germany Jeddah 21382,Kingdom 20th to 24th October type CTs up to 380kV as conforming to National
of Saudi 2015 in IPH Germany Grid SA 50-TMSS-01 Rev.0 with the following
Contact Person - Dr. Andreas Roos, Arabia,http://hnccsa.com Type Test Report, condition
General Manager / SGS Germany
Phone - +49-0-2273-988-70 Tel : 00966 2 ref#3534308-10 WARRANTY:
Email ID - Andreas.roos@eleq.com 6752400,Tel : 00966 2 Ten (10) years Extended Warranty shall be
Website - http://www.eleq.com 6758838, Mobil applicable for Split Core and Continuous Ring
Email : type CTs up to 380kV to be supplied to
info@hnccsa.com,sales SEC/National Grid SA as confirmed through Letter
@hnccsa.com # Nil dated 05.08.2015.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
Website - http://www.pfiffner.com/
Website - http://www.kuhlman.com/
GE
United States
Website - http://www.ge.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.MEMF/YS/LET/08/180, dt: 21st Sep,
2008...
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 12
SIEMENS
United States
Website -
http://www.usa.siemens.com/entry/en/
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
E. PFIFFNER
SWITZERLAND
Website -
http://www.pmw.ch/default.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://www.pfiffner.com/
Website - http://www.sadtem.com/
WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core and Continuous Ring
type CTs up to 380kV to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 05.08.2015.
Website - http://
http://www.alstom.com/home/
GE
United States
Website - http://www.ge.com/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
TYPE TEST SHALL BE DONE AT AN INTL.
TESTING LAB IN PRESENCE OF 3RD PARTY
INSPECTOR
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 19
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
TRENCH ITALIA Type / Model: OIL TYPE PREVIOUSLY AS VA TECH (NOUVA MAGRINI
ITALY GALILEO);
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
ELECTROTECNICA ARTECHE HNOS. Type / Model: Current transformer Tests done in LCOE PQ Letter:
S.L./ E.A.H.S.L Laboratoty (Spain) Based on S&SD letter # 16-010639-030504401
SPAIN •Type CA-170 in presence of dated February 16,2017, Electrotecnica Arteche,
Rating: 110 kV SEC/National Grid Spain-Mungia is pre-qualified for 110 kV CTS as
Plant -Mungia, Spain SA Engineers from conforming to National Grid SA specification #
11th to 19th July, 50-TMSS-01, with the following condition:
Electrotecnica Arteche Hnos. S.L./ 2016).
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea •Ten (10) years extended warranty from the date
Nº28 48100/ of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Contact Person - Mr. Roberto Antuñano of direct material supply order), as confirmed
Phone - +946011200 through Electrotecnica Arteche letter # NIL dated
Email ID - ra@arteche.es January 11, 2010 G.
Website - http://www.arteche.es
KONCAR INSTRUMENT Nesma Telecom & Type / Model: Report No. PQ Letter:
TRANSFORMERS INC. Technology Co. Ltd. 215841P9006&2158 Based on S&SD letter # 20-00850-30504401
CROATIA (NESMA ELECTRIC) Rating: 110 - 132KV 41K19007 dated dated July 5, 2020, the manufacturer is
Nesma Telecom & 16-01-2019 prequalified for 132kV current Transformer type
Plant -Zagreb, Hrvatska, Croatia Technology Co. Ltd. AGU-145 Report No. 018035 AGU-145 with following condition:
(NESMA ELECTRIC), dated 15-11-2018
Josipa Mokrovica 10; HR-10090 Jeddah, Asfan Road WARRANTY:
Zagreb, Croatia inside azzam compound Ten (10) years extended warranty/guarantee in
+966 12 422 9750 Ext. respect of defects due to design, manufacture,
Contact Person - Mr. Marcel Folnović , 3522 +966506513637 installation & workmanship from the date of
Area Manager- Sales & Marketing Rayan@nesma.com Provisional Acceptance Certificate (PAC) of the
Department nesmaelectric@nesma.c first turnkey project in case of contract award or
Phone - +385 1 379 5240, +385 1 379 om date of delivery in case of direct material supply
4112 Mob: +385 99 249 3039 order.
Email ID -
marcel.folnovic@koncar-mjt.hr
Website - http://www.koncar-mjt.hr
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://www.pfiffner.com/
Website - http://www.sadtem.com/
WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core and Continuous Ring
type CTs up to 380kV to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 05.08.2015.
Website - http://www.kuhlman.com/
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All Type, Special, Routine tests per SEC
Standards shal be performed on the first batch,
at anaccredited testing laboratory in the
presence of 03 SEC/National Grid SA engineers
and one approved third party inspector and the
cost of which shall be borne by the
manufacturer.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 16
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
TRENCH ITALIA Type / Model: OIL TYPE PREVIOUSLY AS VA TECH (NOUVA MAGRINI
ITALY GALILEO);
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://www.pfiffner.com/
Website - http://www.sadtem.com/
WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core / Ring type CTs up to
380kV to be supplied to SEC/National Grid SA as
confirmed through Letter# Nil dated 05.08.2015.
Website - http://www.kuhlman.com/
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 15
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
Electrotecnica ARTECHE Hermanos, Innovative Systems Co. CA-420 type test was PQ letter:
S.L. Ltd. performed in LCOE Based on S&SD letter # MPQ # 102210921 dated
SPAIN P.O. Box 60606, Riyadh, lab - Spain 10th to November 08, 2017, Electrotecnica ARTECHE -
KSA 16th July 2017 Spain is pre-qualified for CURRENT
Plant -Mungia, Spain kamal@isys.sa TRANSFORMER,( 380KV CTS)as conforming to
latest National Grid SA specification #
Electrotecnica ARTECHE Hermanos, 50-TMSS-01
S.L.
DERIO BIDEA, 28 (Bº Zabalondo) WARRANTY:
48.100 - MUNGIA Spain Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Mungia installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - LANDER ZUGAZAGA first turnkey project in case of contract award or
& Kamal Al Muhanna date of first delivery in case of direct material
Phone - +34 94 601 1200 supply order, as confirmed by the manufacturer
Email ID - info@arteche.es vide letter # Nil, dated June 30, 2016.
Contact Person Email ID -
lrz@arteche.es & Kamal@isys.sa
Website - www.arteche.es
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
KONCAR INSTRUMENT Nesma Telecom & AGU - 420 Type tests PQ Letter
TRANSFORMERS INC. Technology Co. Ltd. successfully Based on S&SD letter #MPQ456010921 dated
CROATIA (NESMA ELECTRIC), completed in March 16, 2020, the manufacturer is prequalified
Jeddah, Asfan Road Independent lab for 380KV Current Transformer as conforming to
Plant -Zagreb, Hrvatska, Croatia inside azzam compound KONCAR Electrical National Grid SA specification # 50-TMSS-01,
+966 12 422 9750 Ext. Engineering Institute with the following conditions:
Josipa Mokrovica 10; HR-10090 3522; +966506513637 - Croatia during 25 -
Zagreb, Croatia Rayan@nesma.com; 31 October 2019,
nesmaelectric@nesma.c SGS report # WARRANTY
Contact Person - Mr. Marcel Folnović , om 500919, and Ten (10) years extended warranty from the date
Area Manager- Sales & Marketing laboratory report # of PAC of the first turnkey project (in case of
Department 056119. contract award) or date of first delivery (in case
Phone - +385 1 379 5240, +385 1 379 of direct material supply order), as confirmed,
4112 Mob: +385 99 249 3039 3150A Temperature through their Letter # Nil dated May 04, 2018 shall
Email ID - Rise Type test be applicable for the equipment to be supplied to
marcel.folnovic@koncar-mjt.hr successfully SEC/National Grid SA.
Website - http://www.koncar-mjt.hr completed in
Independent lab
KONCAR Electrical
Engineering Institute
- Croatia during 08 -
10 June 2021, SGS
report # 501038-01,
and laboratory
report # 018921.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector, as
confirmed by the manufacturer through their
letter no.CH-5042 Hirchthal, dt: 17th May, 2009..
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.CH-5042 Hirchthal, dt: 17th May,
2009...
Website - http://www.sadtem.com/
WARRANTY:
Ten (10) years Extended Warranty shall be
applicable for Split Core / Ring type CTs up to
380kV to be supplied to SEC/National Grid SA as
confirmed through Letter # Nil dated 05.08.2015.
- Previously KWK Messwandler
Website - http://www.kuhlman.com/
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 16
SIEMENS
GERMANY
Website - http://
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
ABB EJF
CZECH REPUBLIC
Website -
http://www.abb.com/substation-autom
ation
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://
http://www.alstom.com/home/
PFIFFNER, HIRSCHTHAL
SWITZERLAND
Website - http://www.pfiffner.com/
GE
United States
Website - http://www.ge.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: oct 24, 2011.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 14
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://
http://www.alstom.com/home/
PFIFFNER, HIRSCHTHAL
SWITZERLAND
Website - http://www.pfiffner.com/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 11
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
KONCAR INSTRUMENT Nesma Telecom & Type / Model: Type Test Reports: PQ letter:Based on S&SD letter
TRANSFORMERS INC. Technology Co. Ltd. 019010 dated #19-03729-30504401 dated January 5, 2020,
CROATIA Nesma Telecom & Rating: 110 - 132KV 07/02/2019 KONCAR-Instrument Transformer Inc. Croatia for
Technology Co. Ltd. 21584IK19007 dated 132kV Potential Transformer Type: VPU-145 as
Plant -Zagreb, Hrvatska, Croatia (NESMA ELECTRIC), VPU-145 14/01/2019 conforming to latest National Grid SA
Jeddah, Asfan Road 21584IP19006 dated specification # 50-TMSS-03, with the following
Josipa Mokrovica 10; HR-10090 inside azzam compound 14/1/2019 condition:
Zagreb, Croatia
Mr. Rayan Alamoudi , WARRANTY:
Contact Person - Mr. Marcel Folnović , Business Development Ten (10) years extended warranty/guarantee in
Area Manager- Sales & Marketing Manager respect of defects due to design, manufacture,
Department +966506513637 installation & workmanship from the date of
Phone - +385 1 379 5240, +385 1 379 Rayan@nesma.com Provisional Acceptance Certificate (PAC) of the
4112 Mob: +385 99 249 3039 first turnkey project in case of contract award or
Email ID - date of delivery in case of direct material supply
marcel.folnovic@koncar-mjt.hr order.
Website - http://www.koncar-mjt.hr
ELECTROTECNICA ARTECHE HNOS. Type / Model: Potential Transformer Type Test Report # PQ Letter:
S.L./ E.A.H.S.L Rating: 110-132 kV 2017 03 3D 0108 S&SD Letter 12-03192-02-30504001 dated
SPAIN February 19, 2012, it is pre-qualified for 110 –
132 kV Potential Transformers (PT).
Plant -Mungia, Spain
WARRANTY:
Electrotecnica Arteche Hnos. S.L./ Ten (10) years extended warranty/guarantee in
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea respect of defects due to design, manufacture,
Nº28 48100/ installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Roberto Antuñano first turnkey project in case of contract award or
Phone - +946011200 date of delivery in case of direct material supply
Email ID - ra@arteche.es order, as confirmed by the manufacturer thru
Website - http://www.arteche.es letter #nil, dt: jan 11, 2010.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order..
AREVA
United Kingdom
Website - http://www.areva.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #P/900-25112010, dt: 22 mar, 2011.
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 11
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Warranty
Ten (10) years extended warranty/guaranty from
the date of PAC of the first turnkey project (in
case of contract award) and from the date of
delivery (in case of direct material supply order),
as confirmed, through their letter # Nil, dated July
2, 2018 shall be applicable for all 230kV Potential
Transformers (VTs), type UTF-245 to be supplied
to SEC/National Grid SA.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
CONDITION:
All type, special, routine and sample tests as per
SEC specifications/ standards shall be carried
out on the first unit of Inductive Voltage
Transformers to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC Engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory or at the manufacturer’s testing
laboratory. All the related costs for witnessing
the tests will be borne by the manufacturer. This
was confirmed by PFIFFNER Instrument
Transformers Ltd through letter #
P/900-17052011 dated 17 May 2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #P/900-25112010, dt: 22 mar, 2011.
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 11
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-ludvika to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +966 11 2181703
Mobile: +966 500414555
Ludvika, Sweden abdulmajeed.alothman@
hitachienergy.com
Contact Person - Mr. Anders L
katlsson, Mr. Abdulmajeed Alothman
Phone - +46 240 783228
Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Contact Person Email ID -
abdulmajeed.alothman@hitachienergy.c
om
Website - www.hitachienergy.com
Electrotecnica ARTECHE Hermanos, Innovative Systems Co. Type UTF-420 Type Test Report # PQ letter:
S.L. Ltd. 2019 04 3D 0208 Based on S&SD letter # MPQ 108011421 dated
SPAIN P.O. Box 60606, Riyadh, November 27, 2017, Electrotecnica ARTECHE
KSA Spain is pre-qualified for 380kV Potential
Plant -Mungia, Spain kamal@isys.sa Transformers (VTs) as conforming to latest
National Grid SA specification # 50-TMSS-03
Electrotecnica ARTECHE Hermanos, Rev.0 with the following conditions:
S.L.
DERIO BIDEA, 28 (Bº Zabalondo) WARRANTY:
48.100 - MUNGIA Spain Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Mungia installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - LANDER ZUGAZAGA first turnkey project in case of contract award or
& Kamal Al Muhanna date of first delivery in case of direct material
Phone - +34 94 601 1200 supply order, as confirmed by the manufacturer
Email ID - info@arteche.es vide letter # Nil, dated July 08, 2016.
Contact Person Email ID -
lrz@arteche.es & Kamal@isys.sa
Website - www.arteche.es
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 9
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed through Saudi Federal
Transformers L.L.C., Riyadh letter #
SFTL/TES/545/2012 dated May 05, 2012.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by The Saudi
Transformer Co.Ltd., KSA through their letter #
15510277dated May 21, 2018.
Total = 9
TRANSFORMER, SPECIALTY
23. 1
GROUNDING TRANSFORMER, 13.8KV, 33KV OR 34.5KV Applicable Standards: 52-TMSS-01
Website - http://www.cglonline.com/
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea,
Ulsan
Website - http://www.pauwels.com/
Total = 4
TRANSFORMER, SPECIALTY
23. 2
AIR CORE NEUTRAL GROUNDING REACTOR FOR 11 KV THROUGH 132 KV SYSTEM Applicable Standards: 52-TMSS-02
Total = 1
POWER TRANSFORMERS
24. 1
Power Transformer rated up to 100 MVA Applicable Standards: 53-TMSS-01
ILJIN ELECTRIC CO. LTD. META Switchgear Type / Model: for Power Transformers PQ Letter:
SOUTH KOREA Company Based on S&SD Letter # 12-03077-30504401
(Branch of MEMF Rating: 230kV, 166.7MVA dated
905-17, Mannyeon-ro, Hwaseong-si, Electrical Industries co) September 15, 2012 and S&SD letter
Gyeonggi, KOREA 2nd New Industrial Area #15-02407-02-30504401 dated June 23, 2015.
P.O. Box: 355988, ILJIN ELECTRIC Co. Ltd – Hongseong city, Korea
Contact Person - Mr. Jeong Kyung Woo Riyadh 11383 is prequalified for Power Transformers up to 230
, Mr. Jaeho Kim Kingdom of Saudi Arabia kV, 166.7 MVA as conforming to
Phone - +82-2-707-9161 SEC/National Grid SA Specification # 53-TMSS-01
Contact Person Email ID - Mr.Ahmed Elafifi with the following conditions:
jkwoo@iljin.co.kr , jaeho.kim@iljin.co.kr +966536024245
Website - http://www.iljinelectric.co.kr ahmed.elafifi@memf.com CONDITION:
.sa All Type, Routine and Special tests as per
SEC/National Grid
SA Specifications shall be conducted on the
proposed Power Transformers in the
Manufacturer's Testing Laboratory in the
presence of three (3) SEC/National Grid SA
Engineers & one (1) SEC/National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
IL2014-11-05-01 dated November 5, 2014.
WARRANTY:
Ten (10) years extended Warranty for the
proposed Power Transformers in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) and from the date of
delivery for the direct material supply order as
confirmed through the manufacturer letter # Nil
dated November 5, 2014
ELPROM Heavy Industries Type / Model: for Power Transformers Based on TS&SD letter # 11-00438-03-03032301
Bulgaria dated 15/05/2011, it is prequalified for Power
Rating: 132kV, 100MVA Transformers up to 132kV, 100MVA as
Plant -Sofia, Bulgaria confirming to SEC specification # 53-TMSS-01,
Rev.0 with the following conditions:
• All type, special, routine and sample tests as
per SEC specifications/standards for Power
Transformers up to 132kV, 100MVA shall be
carried out in case of contract award or SEC
direct purchase order at SEC approved
independent laboratory or at manufacturer’s
testing laboratory in presence of three (3) SEC
Engineers and one (1) SEC approved
independent inspection agency. All the related
costs for witnessing of the tests will be borne by
the manufacturer. This was confirmed by HHI–
Bulgaria through letter # D-0353 dated
20/08/2010.
• Ten (10) years extended warranty from the
date of PAC of the turnkey project in case of
contract award or date of delivery in case of
direct material supply order. This was confirmed
by HHI–Bulgaria through letter # D-0355 dated
20/08/2010.
PJSC ZAPOROZHTRANSFORMATOR Type / Model: Power Transformers Based on S&SD letter# 13-07568-30504401
(ZTR) dated December 31, 2013, it is pre-qualified for
Ukraine Rating: 132kV, 100MVA Power Transformers rated up to 100MVA, 132
kV as conforming to National Grid SA
Plant -Zaporizhia , Ukraine specification # 53-TMSS-01, Rev.01, with the
following conditions:
• All Type, Special & Routine tests as per latest
National Grid SA Specifications/Standards & IEC
requirements together (with Thermal & Dynamic
short-circuit calculations per IEC 60076-5) shall
be carried out on the next unit to be supplied to
SEC/ National Grid SA in an Accredited Testing
Laboratory in the presence of three (3) National
Grid SA Engineers & one (1) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter
1/115-2261 dated August 15, 2011.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
in writing by the manufacturer through their letter
# 1/115-2266 dated August 15, 2011.
SIEMENS ENERGY (DRESDEN) Type / Model: Power Transformer Previously Name SIEMENS AG (Dresden)
GERMANY
Rating: up to 230kV, 200MVA Prequalified Power Transformer up to 230kV
Website - http://www.simense.com PRIMARY, 200MVA
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea,
Ulsan
Ganz Transformers, Motors, and Type / Model: Power Transformers Previously CG [The name has been changed
Generators LTD. based on letter # 21-00289-30504401 dated 28
HUNGARY Rating: 132kV, 100MVA February 2021].
EFACEC ENERGIA MAQUINAS E 132kV, 100MVA Pre-qualified for Power Transformers rated up to
EQUIPAMENTOS ELECTRICOS, S.A 132kV, 100MVA
PORTUGAL
Plant -Porto/Portugal
SAUDI POWER TRANSFORMERS Type / Model: Power Transformers Type Test Certificate PQ Lettter:
COMPANY (SPTC) #B6003867 dated 24 Based on S&SD Letter # 15-04608-03-30504401
Saudi Arabia 100 MVA, 132 kV February 2017 dated August 18, 2015, It is prequalified for
Power Transformers up to 132 kV, 100 MVA,
Plant -Dammam-Saudi Arabia
CONDITION:
Po Box 6140 Dammam 32232, Building
No. 4292 Unit No. 19 , Saudi Arabia WARRANTY:
Mr. Hosam Al Shaikh, CEO Ten (10) years extended Warranty for the
Phone: +966 13 814 4622 ext 111 proposed Power Transformers rated up to 132
Fax. +966 13 814 4627 kV, 100 MVA in respect of the defects due to
Mobile: +966 50 680 3900 design, manufacturing, installation and
workmanship from the date of the Provisional
Mr. Bahaa Abduieh, Sales & Marketing Acceptance Certificate (PAC) of the project (in
Manager case of contract award) and from the date of
Phone: + +966 13 814 4622 ext 133 delivery for the direct material supply order as
Fax. +966 13 814 4627 confirmed through the manufacturer letter# CEO
Mobile: +966 50 0082841 /2015 /008 dt:Aug 8, 2015.
Email ID - ceo@sptc.com.sa,
sales@sptc.com.sa
SCHNEIDER ENERJI ENDUSTRISI SAN Type / Model: Power Transformers Pre-qualified for Power Transformers rated up to
VE TIC A.S 132kV, 67MVA
TURKEY Rating: 132kV, 67 MVA Based on S&SD letter# 14-02364-1-30504401
dated April 01, 2014, it is pre-qualified for Power
Plant -Cayirova-Kocaeli-Turkey Transformers up to 67 MVA and, 132 kV
conforming to National Grid SA specification
Tosb Organize Sanayi Bölgesi 1.Cadde 53-TMSS-01, Rev. 01, with the following
No:6 Çayırova Kocaeli conditions:
• All Type, Special & Routine tests as per National
Contact Person - Mr. Orhan Unal Sales Grid SA Specifications/Standards shall be carried
Manager out on the first unit to be supplied to National Grid
Email ID - SA in the manufacturer Testing
orhan.unal@schneider-electric.com Laboratory in the presence of three (03) National
Grid SA Engineers & one (01) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
MKT_132KV Trafo_005, dated June 18, 2013.
• Schneider Electric Transformer Factory -
Cayirova, Istanbul, Turkey has confirmed that
“improvement needs implementation will be
complied during the FAT for the first transformer
order” confirmed through letter # MKT_132KV
Trafo_010 dated February 12, 2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) or from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # MKT_132KV Trafo_007-1 dated March
19, 2014.
- Previously "AREVA-Turkey", the name has been
changed to Schneider Electric-Turkey based on
Schneider Electric letter # MKT-18.01.11 dated
18/01/2010 and AREVA T&D letter #
BF/BL25.11.2010.
ABB ELEKTRIK SANAYI A.S. ABB Saudi Arabia, Type / Model: ZTR CONDITION:
[PREVIOUSLY ABB ESAS] Al-Khobar Pre-Qualification & Participation for current &
TURKEY CONTACT PERSON: Rating: 132kV, 100MVA future SEC's Projects subjected to the mutual
Rasim Duran agreement between SEC & ABB dated 09 March
Plant Phone: 0554446258 2009
-Turkey-Istanbul/Kartaladdress:Esentep rasim.duran@sa.abb.co
e Mahallesi, Milangaz Cad m
Website - http://www.pauwels.com/
GETRA POWER S.P.A Type / Model: Power Transformer Based on S&SD Letter # 14-04523-01-03504401
ITALY dated 7th July 2014, it is pre-qualified for Power
Rating: 132kV , 100MVA Transformer up to 100MVA, 132kV as confirming
Plant -Plant Location : Marcianise (Ce) , to National Grid SA specification # 53-TMSS-01,
Italy Rev.01 with the following conditions:
• All Type, Special & Routine tests as per National
Grid SA Specifications/Standards shall be carried
out on the first unit to be supplied to National Grid
SA in an Approved Independent
Testing Laboratory and/or in the manufacturer’s
Testing Laboratory in the presence of three (03)
National Grid SA Engineers & one (01) Approved
Independent Inspection Agency (IIA) Inspector.
All the costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the
manufacturer through their letter #
GPJLT/SECNG/SSD/009, dated 8th June 2014.
• WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter # GPJLT/SECNG/SSD/0010 dated 8th
June 2014.
KONCAR D&ST INC. Type / Model: Power Transformer Pre-qualified for Power Transformers rated up to
CROATIA 132kV, 67MVA
Rating: 132kV, 67MVA
Plant -Zagreb/ Based on S&SD Letter # 14-03217-1-30504401
Croatia-Hrvatskaaddress: dated May 18, 2014, it is pre-qualified for Power
Transformer up to 67MVA, 132kV as confirming
Koncar Distribution & Special to National Grid SA specification # 53-TMSS-01,
Transformers D&St, J. Mokrovica 8; Rev.01 with the following conditions:
P.P. 100; Hr-10090 Zagreb, Croatia • All Type, Special & Routine tests as per National
Grid SA Specifications shall be carried out on the
Contact Person - Mr. Kopjar Boris first unit to be supplied to National Grid SA in the
Phone - +385 1 3783 728 Mob: + 385 Approved Independent Testing Laboratory or in
99 2110 846 the manufacturer’s Testing Laboratory in
Email ID - Boris.kopjar@koncar-dst.hr presence of three (03) National Grid SA
Website - http://www.koncar-dst.hr/ Engineers & one (01) Approved Independent
Inspection Agency (IIA) Inspector. All the costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil, dated May 04, 2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # Nil dated May 04, 2014.
AREVA
GERMANY
Website - http://www.areva.com/
SC ELECTROPUTERE SA Type / Model: Power Transformer ON HOLD for the procurement of Power
Romania Transformer for all ongoing and forthcoming
Rating: 132kV, 100MVA projects of company including the Eight (8) spare
Plant -Craiova, Romania transformers against purchase order #
4500217223 as per S&SD fax#
16-05458-30504401 dated 23/06/2016.
KONCAR POWER TRANSFORMERS Type / Model: Power Transformer Based on S&SD Letter # 14-08041-01-03504401
LTD dated 13/02/2014 & 14-08041-02-03504401
CROATIA Rating: up to 132kV, 100MVA dated 25/03/2014, it is pre-qualified for Power
Transformer up to 100MVA, 132kV as confirming
Plant -Josipa Mokrovica 6 to National Grid SA specification # 53-TMSS-01,
Rev.01 with the following conditions:
10 090 Zagreb, Coratia • All Type, Special & Routine tests as per National
Grid SA Specifications/Standards shall be carried
Contact Person - Mr. Ivan Milcic, GM out on the first unit to be supplied to National Grid
Phone - +385 1 3795 555 SA in the Approved Independent Testing
Laboratory or in the manufacturer’s Testing
Laboratory in presence of three (03) National
Grid SA Engineers & one (01) Approved
Independent Inspection Agency (IIA) Inspector.
All the costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # Nil, dated
01-04-2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) or from the date of first
delivery in case of direct material supply order,
as confirmed by the manufacturer through their
letter # 2014/02, dated 01-04-2014 dated April 06,
2014
Weiz , Austria
Website - http://www.vatechetg.at/
GRID SOLUTIONS ENERJI ENDUSTRISI SUSPENDED for all SEC/National Grid SA ongoing
ANONIM SIRKETI and forthcoming projects based on VP,
TURKEY Engineering letter # 19-00366-30504401 dated
February 17, 2019.
New Remark
Previously ALSTOM GRID, GEBZE.
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].
Website -
http://www.toshiba.co.jp/index j3.htm
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com
Plant -NURNBERG
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Total = 27
POWER TRANSFORMERS
24. 2
Power Transformer rated above 100 MVA Applicable Standards: 53-TMSS-01
Website - http://www.pauwels.com/
ILJIN ELECTRIC CO. LTD. META Switchgear Type / Model: Power Transformers PQ Letter:
SOUTH KOREA Company S&SD Letter # 12-03077-30504401 dated
(Branch of MEMF Rating: 230 kV, up to 166.7MVA September 15, 2012 and S&SD letter #
905-17, Mannyeon-ro, Hwaseong-si, Electrical Industries co) 15-02407-02-30504401 dated June 23, 2015.
Gyeonggi, KOREA 2nd New Industrial Area ILJIN ELECTRIC Co. Ltd – Hongseong city, Korea
P.O. Box: 355988, is prequalified for Power Transformers up to 230
Contact Person - Mr. Jeong Kyung Woo Riyadh 11383 kV, 166.7 MVA as conforming to SEC/National
, Mr. Jaeho Kim Kingdom of Saudi Arabia Grid SA Specification # 53-TMSS-01 with the
Phone - +82-2-707-9161 following conditions:
Contact Person Email ID - Mr.Ahmed Elafifi
jkwoo@iljin.co.kr , jaeho.kim@iljin.co.kr +966536024245 CONDITION:
Website - http://www.iljinelectric.co.kr ahmed.elafifi@memf.com All Type, Routine and Special tests as per
.sa SEC/National Grid SA Specifications shall be
conducted on the proposed Power Transformers
in the Manufacturer's Testing Laboratory in the
presence of three (3) SEC/National Grid SA
Engineers & one (1) SEC/National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
IL2014-11-05-01 dated November 5, 2014.
WARRANTY:
Ten (10) years extended Warranty for the
proposed Power Transformers in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) and from the date of
delivery for the direct material supply order as
confirmed through manufacturer letter # Nil dated
November 5, 2014.
SIEMENS ENERGY (DRESDEN) Type / Model: Power Transformer Previously Name SIEMENS AG (Dresden)
GERMANY
Rating: up to 230kV, 200MVA Prequalified for Power Transformer up to 230kV,
Website - http://www.simense.com 200MVA
ABB CORDOBA ABB Saudi Arabia, Type / Model: Power Transformer Prequalified for power transformer up to 500
SPAIN Al-Khobar MVA
CONTACT Rating: up to 380kV, 500MVA
Plant -Cordoba, Spain PERSON:Rasim Duran Based on TS&SD letter#
Phone - 0554446258 09-F011657/03-03032301 dated August 16, 2009.
Escritor Conde Zamorea, S/N ,14004 Email - It is pre-qualified for Power Transformer up to
Cordoba (Spain) rasim.duran@sa.abb.co 380kV, 500MVA as confirming to SEC
m specification # 53-TMSS-02, rev.0 with the
Contact Person - Mr. Evan Smith following conditions:
Phone - +34608749306 • All type, design, special (exclude Short-Circuit
Email ID - evan.smith@es.abb.com Test) & routine tests as per SEC
Website - Specifications/Standards together with Thermal &
http://new.abb.com/products/transform Dynamic short-circuit calculations per IEC
ers 60076-5 shall be carried out on the first unit to be
supplied to SEC in an accredited Independent
Testing Laboratory or in the manufacturer 's
testing laboratory in the presence of three (3)
SEC Engineers & one (1) SEC approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter #
PPTR-002.2 dated February 14, 2009 and the
submitted "Confirmation Letter" # Nil dated
November 18, 2008. [this condition has been
modified based on S&SD letter#
12-0395-01-30504001 dated February 12, 2012]
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea,
Ulsan
ABB ELEKTRIK SANAYI A.S. ABB Saudi Arabia, Type / Model: Power Transformer Prequalified for power transformer up to 250 MV
[PREVIOUSLY ABB ESAS] Al-Khobar only
TURKEY CONTACT Rating: 380kV, 250MVA
PERSON:Rasim Duran Based on S&SD letter# 14-02898/03-030504401
Plant Phone - 0554446258 dated June 17, 2014, it is pre-qualified for Power
-Turkey-Istanbul/Kartaladdress:Esentep Email - Transformer up to 380kV, 250MVA as confirming
e Mahallesi, Milangaz Cad rasim.duran@sa.abb.co to National Grid SA specification # 53-TMSS-02,
m Rev.01 with the following conditions:
Esentepe Mahallesi, Milangaz Cad No.
52 Kartal 34870, Istanbul -Turkey • All Type, Routine and Special testes as per NG
Specifications/Standards and IEC requirement
Contact Person - Mr. Sezgin Perdahci together with Thermal & Dynamic short-circuit
Phone - +90-533-666-8067 calculations per IEC 60076-5 shall be carried out
Email ID - E-mail : on the First unit to be supplied to SEC/NG of
sezgin.perdahci@tr.abb.com Power Transformers in the Manufacturer's
Website - http://www.abb.com Testing
Laboratory in the presence of three (3) SEC/NG
Engineers & one (1) SEC/ NG approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # Nill dated
February 04, 2013 .
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter #Nill dated May 24, 2013.
AREVA
GERMANY
Website - http://www.areva.com/
WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) and date of first delivery (in
case of direct material supply order), as
confirmed, through their Letter No.
BEST-100316-SEC-01 dated 10 March 2016.
KONCAR-POWER TRANSFORMERS, Siemens Ltd.- Saudi up to 380kV & 500MVA Previously Name KONCAR POWER
Croatia (A joint Venture of Siemens Arabia TRANSFORMERS LTD. (A joint venture of
Energy and Koncar) Siemens Ltd., 02nd floor, Siemens and KONCAR)
CROATIA Juffali Tower , P.O
Box#719, Al-Khobar Based on S&SD letter # 17-03229-05-30504401
Josipa Mokrovica 12, 10090 Zagreb 31952, Kingdom of Saudi dated May 17, 2017, Koncar Power
Arabia Transformers Ltd, Croatia (A joint Venture of
Contact Person - Mr. Nidzar +966 (13) 865 9680 Siemens and Koncar) is pre-qualified for Power
Turcinhodzic Kaisar.langoo@siemens. Transformer rated up to 380kV & 500MVA as
Phone - +38513794075 com conforming to National Grid SA specification #
Email ID - Kpt.hr@siemens.com 53-TMSS-01, with the following conditions:
Contact Person Email ID -
Nidzar.turcinhodzic@siemens.com •Ten (10) years extended warranty from the date
Website - http://www.koncar-dst.hr/ of PAC of the project (in case of contract award)
or date of delivery (in case of direct material
supply order), as confirmed, through their Letter
No. NIL dated June 6, 2016 shall be applicable for
all Power Transformers rated up to 380kV &
500MVA to be supplied to SEC/National Grid SA.
Weiz , Austria
Website - http://www.vatechetg.at/
GRID SOLUTIONS ENERJI ENDUSTRISI SUSPENDED for all SEC/National Grid SA ongoing
ANONIM SIRKETI and forthcoming projects based on VP,
TURKEY Engineering letter # 19-00366-30504401 dated
February 17, 2019.
New Remark
Previously ALSTOM GRID, GEBZE
CONDITION:
First Unit to be Type Tested in the presence of 03
SEC Engineers & 1 SEC approved Independent
Inspector
WARRANTY:
Six (6) years extended Warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].
HYOSUNG HEAVY INDUSTRIES Type / Model: Power Transformer Prequalified for power transformer up to 500
CORPORATION (HICO) MVA
SOUTH KOREA Rating: 380kV, 500MVA
Based on TS&SD fax#09-F01255/02-03032301
Plant -Republic of Changwon, Korea dated 25th. July 2009, it is pre-qualified for
Power Transformer up to 380kV, 500MVA as
Eric Rhie, 450, Gongdeok-Dong, confirming to SEC specification # 53-TMSS-02,
Mapo-Gu, Seoul , Korea rev.0
Tel:82-707-6180 with the following conditions:
Contact Person - Mr. Jason Kang; Sale • All type, design, special & routine tests as per
Manager & Mr. Young Kim; Sales SEC specifications/standards shall be carried out
Manager on the first batch to be supplied to SEC in
Contact Person Email ID - securing an order in the presence of three
Jason.kang@hyosung.com , (3) SEC engineers & one (1) approved
yw.kim@hyosung.com independent inspection agency Inspector.
Website - • Seven (7) years warranty from the date of PAC
http://www.hyosung.co.kr/eng/index.js of the turnkey project in case of contract award
p?, www.hyosung.com or date of delivery in case of direct material
supply order.
MITSUBISHI ELECTRIC CORPORATION Type/Model - Shell type ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Website -
http://www.toshiba.co.jp/index j3.htm
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com
Plant -NURNBERG
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Total = 18
WARRANTY:
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.SSG/SEC/11, DT: 20TH April, 2007
Total = 2
RESISTOR
26. 1
NEUTRAL GROUNDING RESISTOR, 11 KV THROUGH 34.5 KV Applicable Standards: 57-TMSS-01
CRESSAL RESISTOR
United Kingdom
Website - http://www.cressall.com/
M.S.RESISTANCES WARRANTY:
FRANCE Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Website - installation & workmanship from the date of
http://www.msresistances.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
METAL DEPLOYE
FRANCE
Website -
http://www.metaldeploye.com
NATIONAL
INDIA
FURSE
United Kingdom
Website -
http://www.furse.com/home.htm
Total = 6
REACTOR
27. 1
OIL IMMERSED REACTORS, (33 KV TO 69 KV ) Applicable Standards: 58-TMSS-01
MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Website -
http://www.toshiba.co.jp/index j3.htm
WARRANTY:
•Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # BEST-100339-SEC-02, dated August
08, 2016.
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].
CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Specifications & IEC
requirements [excluding Short circuit test ] shall
be carried out on the first unit to be supplied to
SEC/National Grid SA in the manufacturer
Laboratory in the presence of three (3) National
Grid SA Engineers & one (1) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #Nil dated
November 10, 2012.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter #Nil dated 25 November 2014.
Website - http://www.areva.com/
Hyundai Electric & Energy Systems Co. Type / Model: Shunt Reactor PQ Letter:
Ltd TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA August 31,2010 and 13-05782-1-30504401,
December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor as conforming to National Grid SA
specification # 58-TMSS-01, Rev.0 with the
1000, Bangeojinsunhwan-doro, following condition.
Dong-gu, Ulsan, South Korea,
CONDITION:
Ulsan
WARRANTY:
Contact Person - Mr. Young Jun Bae Ten (10) years extended warranty/guarantee in
(Regional General Manager) , Mr. Lee respect of defects due to design, manufacture,
Chung Hee (Vice President (Power installation & workmanship from the date of
Infrastructure Sales & Marketing – II)) Provisional Acceptance Certificate (PAC) of the
Phone - +966-11-293-2026, first turnkey project in case of contract award or
+82-31-8006-6837 date of delivery in case of direct material supply
Contact Person Email ID - order and subsequently reduced yearly in case
peterbae@hyundai-electric.com , of future project award. This was confirmed by
kolch@hyundai-electric.com HHI –Korea through letter #S370 -1008-0182
Website - dated 18/08/2010.
http://www.hyundai-elec.com
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #1/115-3552
dated December 14, 2011.
Hitachi Energy Sweden AB Hitachi Energy Type / Model: Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia Rating: up to 69kV
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com
Total = 15
REACTOR
27. 2
OIL IMMERSED REACTORS, (110 KV TO 132 KV ) Applicable Standards: 58-TMSS-01
HITACHI LTD Rating - upto 380 kv Class Test Report No. - will Originally JAPAN AE POWER SYSTEM CORP and
JAPAN be submitted after subsequent change affected as per HITACHI
CN letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 132kV
Plant -T&D Systems Center, Amagasaki
City, Japan
Website -
http://www.toshiba.co.jp/index j3.htm
WARRANTY:
•Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation and workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
vide letter # BEST-100339-SEC-02, dated August
08, 2016.
ABB ( T& D)
United States
Website - http://www.abb.us/
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].
CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Standards & IEC requirements
[excluding Short circuit test ] shall be carried out
on the first unit to be supplied to SEC/National
Grid SA in the manufacturer Laboratory in the
presence of three (3) National Grid SA Engineers
& one (1) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil, dated November 10,
2012.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated 25
November 2014.
Website - http://www.areva.com/
Hyundai Electric & Energy Systems Co. Type / Model: Shunt Reactor PQ Letter:
Ltd TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA Rating: 132kV August 31,2010 and 13-05782-1-30504401,
December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor.
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter # 1/115-3552
dated December 14, 2011.
Hitachi Energy Sweden AB Hitachi Energy Type / Model: Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia Rating: up to 132kV
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com
Total = 15
REACTOR
27. 3
OIL IMMERSED REACTORS, (230 KV) Applicable Standards: 58-TMSS-01
HITACHI LTD Rating - upto 380 kv Class Test Report No. - will Originally JAPAN AE POWER SYSTEM CORP and
JAPAN be submitted after subsequent change affected as per HITACHI
CN letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 230kV
Plant -T&D Systems Center, Amagasaki
City, Japan
Website -
http://www.toshiba.co.jp/index j3.htm
ABB ( T& D)
United States
Website - http://www.abb.us/
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].
Website - http://www.areva.com/
Hyundai Electric & Energy Systems Co. Type / Model: Shunt Reactor PQ Letter:
Ltd TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA Rating: 230kV August 31,2010 and 13-05782-1-30504401,
December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor.
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Hitachi Energy Sweden AB Hitachi Energy Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456
amit.x.nikhare@hitachien
Ludvika, Sweden ergy.com
Total = 12
REACTOR
27. 4
OIL IMMERSED REACTORS, (380 KV ) Applicable Standards: 58-TMSS-01
HITACHI LTD Type / Model: Oil Immersed Shunt Originally JAPAN AE POWER SYSTEM CORP and
JAPAN Reactors subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan Rating: FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
MITSUBISHI ELECTRIC CORPORATION Type / Model: Oil Immersed Shunt ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN Reactors DURING APRIL 2005.
Website -
http://www.toshiba.co.jp/index j3.htm
FUJI ELECTRIC CO. Type / Model: Oil Immersed Shunt Originally JAPAN AE POWER SYSTEM CORP and
JAPAN Reactors subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Rating: FUJI letter # AT-LTR-121115-1, dated 18-12-2012.
HYOSUNG HEAVY INDUSTRIES Type / Model: Oil Immersed Shunt Type, Routine PQ Letter:
CORPORATION (HICO) Reactors &Special tests shall S&SD letter # 14-10289-02-30504401 dated 18
SOUTH KOREA be conducted January 2015, the manufacturer is prequalified
Rating: 380kV for Oil Immersed Reactor up to 380 KV.
Plant -Republic of Changwon, Korea
CONDITION:
Eric Rhie, 450, Gongdeok-Dong, All type, special, routine tests for Oil Immersed
Mapo-Gu, Seoul , Korea Shunt Reactors per National Grid SA
Tel:82-707-6180 specifications and IEC standards & technical
requirements shall be conducted at
Contact Person - Mr. Jason Kang; Sale Manufacturer's Testing Laboratory in presence of
Manager & Mr. Young Kim; Sales three (3) SEC/National Grid SA engineers & one
Manager (1) company approved independent inspection
Contact Person Email ID - agency Inspector, at the sole expenses of
Jason.kang@hyosung.com , manufacturer on the first unit to be supplied to
yw.kim@hyosung.com SEC/National Grid SA. This was confirmed
Website - through their letter # HS-SR-141027-01 dated
http://www.hyosung.co.kr/eng/index.js October 27, 2014.
p?, www.hyosung.com
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by manufacturer and
subsequently reduced yearly in case of future
project award through their letter#
HS-SRPQ-150107-01 dated January 7, 2015.
Website - http://www.abb.us/
GRID SOLUTIONS ENERJI ENDUSTRISI Type / Model: Oil Immersed Shunt SUSPENDED based on VP, Engineering letter #
ANONIM SIRKETI Reactors 20-0045-01-30504101 dated April 14, 2020
TURKEY
Rating: 380 kV Previously ALSTOM GRID, GEBZE
PQ Letter:
S&SD letter# 13-04034-2-30504401 dated
September 12, 2013, pre-qualified for 380 kV Oil
Immersed Shunt Reactors.
CONDITION:
All type/special, routine tests for 380 kV Oil
Immersed Shunt Reactors on one unit of each
rating supplied to SEC shall be conducted at
Manufacturer's Testing Laboratory in presence of
three (3) SEC/National Grid SA engineers & one
(1) SEC approved independent inspection agency
Inspector, all the related costs for witnessing the
tests will be borne by the manufacturer. This
was confirmed by Alstom Grid, Turkey through
their letter # Nil, dated July 22, 2013.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by Alstom Grid, Turkey
through their letter # Nil, dated July 22, 2013.
Hyundai Electric & Energy Systems Co. Type / Model: Oil Immersed Shunt PQ Letter:
Ltd Reactors TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA August 31,2010 and 13-05782-1-30504401,
Rating: 380kV December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor.
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Hitachi Energy Sweden AB Hitachi Energy Type / Model: Oil Immersed Shunt Mfr. Name change from ABB-AB to Hitachi
SWEDEN Hitachi Energy Ltd. Reactors Energy Sweden AB
Riyadh, Saudi Arabia
Plant -Sweden Phone: +46107384456 Rating:
amit.x.nikhare@hitachien 380kV
Ludvika, Sweden ergy.com
Total = 13
REACTOR
27. 5
AIR CORE SERIES REACTOR, 13.8KV THROUGH 380KV (230 KV AIR CORE Applicable Standards: 52-TMSS-02, 58-TMSS-02
NOKIAN – GRID SOLUTIONS OY LTD. Type / Model: Air core series reactor PQ Letter:
FINLAND S&SD letter # 14-03642-01-30504401 dated June
Rating; 145kV 11, 2014, NOKIAN – ALSTOM Grid oy Ltd.
Tampere , Finland Tampere-Finland is pre-qualified for Air Core
P.O.Box 4, Kaapelikatu 3 fl-33331 Series Reactors up to145 kV.
Vehmaistenkatu 5 fl-33730
WARRANTY:
Phone - +358 3 388311 Ten (10) years extended warranty/guarantee in
Email ID - firstname.surname@ge.com respect of defects due to design, manufacture,
Website - www.gegridsolutions.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter # Nil, dated 20th June 2012.
POWER ECONOMY MIDDLE EAST CO. Type / Model: Air core Reactor. PQ Letter:
United Arab Emirates Based on TS&SD letter #07-F691-03032300
Rating: Limited to 34.5kV only dated May 21, 2007, it is pre-qualified for Air Core
Plant -Abu Dhabi , United Arab Emirates Reactors Limited to 34.5kV only
Website - WARRANTY:
http://www.powereconomy.net/ Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed through the manufacturer
letter # O-694-KSA-SEC, dated 20th Nov,2006.
WARRANTY:
Seven (7) years Extended Warranty shall be
applicable for the Air Core Series Reactors to be
supplied to SEC by TRENCH CANADA as
confirmed through their letter # NIL dated April 28,
2010.
Total = 4
CELLMEC
BAHRAIN
Website - http://www.cellmec.com/
Total = 1
ABB
SWITZERLAND
Total = 2
Website -
http://www.atlanticwood.com/
COLFAX CREOSOTING CO
United States
KOPPERS INDUSTRIES
United States
Pa , United States
Website - http://www.koppers.com/
STALLWORTH TIMBER
United States
Website -
http://www.stella-jones.com/welcome
eng.htm
Website -
http://www.taylorlumberinc.com/
Total = 7
Website -
http://www.atlanticwood.com/
COLFAX CREOSOTING CO
United States
KOPPERS INDUSTRIES
United States
Pa , United States
Website - http://www.koppers.com/
STALLWORTH TIMBER
United States
Website -
http://www.stella-jones.com/welcome
eng.htm
Website -
http://www.taylorlumberinc.com/
Total = 7
UNIBUS
United States
ABB ( T& D)
United States
Website - http://www.abb.us/
WESCOSA
Saudi Arabia
Total = 3
SWITCHES
32. 1
LV AUTO-TRANSFER SWITCH Applicable Standards:
ALSTOM
FRANCE
Website -
http://www.alstom.com/home/
ASCO
United Arab Emirates
Website - http://www.asco.co.ae
WESTINGHOUSE
United States
Website -
http://www.westinghouse.com
Total = 3
SWITCHES
32. 2
PAD MOUNTED SF6/OIL SWITCH, 34.5 KV Applicable Standards:
FRITZ DRIESHER KG
GERMANY
Website -
http://www.driescher.de/home/index.ht
m
Total = 1
SWITCHES
32. 3
CIRCUIT SWITCHER, 69 –230 KV Applicable Standards:
S&C
United States
Website - http://www.sandc.com/
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
S&C ON HOLD
CANADA
Total = 3
TRANSDUCERS
33. 1
FREQUENCY TRANSDUCERS Applicable Standards:
ALSTOM
United States
Website -
http://www.alstom.com/home
ISKRA MIS Adnan Sabban Type/Model - Saprk Energy DZ9 ACCEPTANCE SUBJECTED TO SUCCESSFUL
SLOVENIA Est Office #6 1st Floor Al PRODUCT EVALUATION / ACCEPTANCE BY SEC
Hamad II Center Al Zahra CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia District PURCHASE ORDER / PROJECT DURING
050-55-989-84 ,Phone - TENDER/BIDDING STAGE.
050-55-989-84
zakaria@ase-ksa.com
Total = 2
TRANSDUCERS
33. 2
TAP POSITION TRANSDUCERS Applicable Standards:
AREVA
United Kingdom
Website - http://www.areva.com/
Total = 1
TRANSDUCERS
33. 3
TRANSDUCERS Applicable Standards:
Website -
http://www.ceweinstrument.se/
ENERDIS
FRANCE
Website -
http://www.chauvin-arnoux.com/
TILLQUIST
SWEDEN
Website - http://www.tillquist.com/
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order. This was confirmed by TYCO Electronic,
UK through their letter # INT-SEC-06 dated
Jamuary 03, 2008 and its amendment dated
November 21, 2011
LSIS , WARRANTY
SOUTH KOREA Seven (07) years extended warranty/guarantee
in respect of defects due to design, manufacture,
Ls Tower, 127, Ls-Ro, Dongan-Gu, installation & workmanship from the date of
Anyang-Si, Gyeonggi-Do, Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Mr. Je-woo, Lee date of delivery in case of direct material supply
Assistant Manager order.
Phone - +82-2-2034-4541
Email ID - jwleea@lsis.com
Website - http://www.lsis.com
Total = 5
TRANSDUCERS
33. 4
WATTHOURS/VARHOURS TRANSDUCERS Applicable Standards:
ISKRA MIS Adnan Sabban Type/Model - Sparklight , ADM 16 ACCEPTANCE SUBJECTED TO SUCCESSFUL
SLOVENIA Est Office #6 1st Floor Al PRODUCT EVALUATION / ACCEPTANCE BY SEC
Hamad II Center Al Zahra CONCERNED END USER DEPARTMENT FOR EACH
Kranj , Slovenia District PURCHASE ORDER / PROJECT DURING
Phone - 050-55-989-84 TENDER/BIDDING STAGE.
Email -
zakaria@ase-ksa.com
MITSUBISHI ELECTRIC
JAPAN
Website -
http://global.mitsubishielectric.com/
SCIENTIFIC COLUMBUS
United States
Website -
http://www.scientificcolumbus.com/
Total = 3
TRANSDUCERS
33. 5
VOLTAGE TRANSDUCERS Applicable Standards:
Montreal , Canada
Website - http://www.abb.ca/
TRANSDATA
United States
Website -
http://www.transdatainc.com/index.ht
m
AREVA
United Kingdom
Website - http://www.areva.com/
Total = 4
TRANSDUCERS
33. 6
WATTS/VARS TRANSDUCERS Applicable Standards:
Montreal , Canada
Website - http://www.abb.ca/
TRANSDATA
United States
Website -
http://www.transdatainc.com/index.ht
m
AREVA
United Kingdom
Website - http://www.areva.com/
Total = 4
CONDITION
Type test shall be conducted in independent
testing laboratory for the SAS System as per
National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer by
ALSTOM Grid AG –France, U.K through their
letter SAS/TSSD/2014/WR1201-1 dated January
12, 2014.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.
Plant -2Nd Industrial Area,Riyadh,, Previous name was ABB Electrical Industries
Company Ltd, and change to ABB Contracting Co.
Po Box 325841 Riyadh,11371 KSA Ltd based on S&SD letter #20-01681-30504401
dated October 01, 2020
Riyadh
Warranty
•Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their letter # PGGA/SAS/0101, dated
February 4, 2018 shall be applicable for all 380
kV SUBSTATION AUTOMATION SYSTEM (SAS),
to be supplied to SEC/National Grid SA.
Type Test
•Type Tests shall be conducted on the SAS
System as per the new IEC 61850-10 (2012-12)
Edition 2 in an accredited laboratory in presence
of three (3) SEC/National Grid SA Engineers and
one (1) Company approved IIA Inspector at the
sole expense of ABB as confirmed through their
letter # PSN/SAS/0709/08/2013, dated July 9,
2013
Old remarks:
PQ Lettter
Based on S&SD letter# 14-00953-1-30504401
dated February 27, 2014, ABB Automation Co.
Ltd., Riyadh is pre-qualified for integration and
testing of SAS systems for substations rated up
to 230kV against specification # TES-P-107.01,
Rev.00 with the following conditions:
CONDITION
Type test shall be conducted in independent
testing laboratory for the SAS System as per
National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer by
ABB-Riyadh through their letter #
PSN/SAS/0709/08/2013 dated July 09, 2013.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
30 DO + 8 AI}
( 8 Analog Current Inputs selectable 4-20 mA, 0-1
mA, 0-5 mA, 0-10 mA, 0-20 mA )
SAS Equipment:
SEL PQ Lettter
United States Based on the S & SD letter# 14-01257-30504401
dated 23 March 2014, Schweitzer Engineering
Laboratory (SEL) -U.S.A is prequalified for
Substation Automation System (SAS) with
Integration and Testing of SAS to be performed
only by (SEL), at SEL Al-Khobar, KSA for SAS
Panels as Integration and testing of SAS panels
with following condition:
CONDITION
Type Tests: The manufacturer has confirmed to
perform the required type tests in Independent
Testing laboratories- KEMA as per SEC/National
Grid SA requirements, IEC 61850 Edition 2
standards in the presence of three (3)
SEC/National Grid SA Engineers and one (1)
Independent Inspector through reference letter #
SEL/SAS/08/2013.
WARRANTY
The manufacturer has agreed to give guarantee/
warranty to SEC/National Grid SA for the
proposed Substation Automation System (SAS)
from SEL U.S.A with Integration & Testing facility
at SEL Al-Khobar, KSA for SAS Panels as
Integration and testing of SAS panels in respect
of the defects due to design, manufacturing,
installation and workmanship for a period of ten
(10) years , This was confirmed in writing by the
manufacturer through their letter ref:
LSELSA/17-34,
dated June 14, 2017.
SIEMENS Siemens Ltd IC SG EA Type/Model - Substation Automation Bay Controller Unit Old comments:
GERMANY Pro System (FOR NEW TYPE):
Jeddah 21412 Baladiyah Rating - 380 kV 13.8 kV Type test Report PQ Lettter
Plant -NURNBERG Germany Street PO Box 4621 Mr. #G0M-1412-4383-S Based on the S&SD letter#
Ahmad Ainousah 0C000-V01 Dated: 14-03345-02-30504401 dated May 20, 2014,
Ic Sg Ea Mf Wernerwerkdamm 5 13629 Phone - Bay Controller Unit December,2014 SIEMENS -Germany is prequalified for Substation
Berlin Germany. +966-12-6618869 (Old Type) Automation System (SAS) with Integration and
Email - Type 6MD85 Laboratory:Eurofins Testing at SIEMENS–Jeddah K.S.A up to 380kV
Phone - +49(30)386-26688 ahmad.ainousah@sieme Ordering code: ProductService projects subject to the following conditions
Email ID - ns.com 6MD85-P1G33877 GmbH
hartmut.von.zander@siemens.com Built-in functions: & RTDS Test Report CONDITION
CONTROL & MIMIC # EM DG PTI PSC Type test shall be conducted in independent
SYNCH Check /pc200768 / VH testing laboratory for the SAS components as
Metering Dated per National Grid SA requirements latest revision
Interlocking December,016 of IEC 61850 (edition 2) on the approved
Supervision & Monitoring Functions: Laboratory: Independent Testing laboratory witnessing by
CT supervision Siemens Germany three (3) National Grid SA engineers and one (1)
74TC AG approved Independent Agency Inspector (IIA). All
74DC Supervision costs of witnessing the tests shall be borne by
74 Lockout Supervision the Siemens – Jeddah K.S.A as per their
60VT confirmation through letter # Nil dated April 21,
DFR/SOE 2014.
Hardware:
4 CT Measurements WARRANTY:
12 VT = 3 X 4 VT SETS ( Upper BB, Ten (10) years extended warranty/guarantee in
Lower BB, respect of defects due to design, manufacture,
line ) VT`s installation & workmanship from the date of PAC
115 BI of the first turnkey project (in case of contract
09 BO award) or from the date of first delivery in case
IEC61850 -PRP x 2 FO ports of direct material supply order as confirmed from
(New Type) SIEMENS -Germany & for Integration & Testing
Type 6MD85 facility at SIEMENS –Jeddah K.S.A the
Ordering code: Siemens-Germany & Siemens –Jeddah K.S.A
6MD85-P1G33886 through their letter # Nil dated November 12,
Built-in functions: 2012.
CONTROL & MIMIC
SYNCH Check Bay Controller Unit (BCU) : type 6MD6 from
Metering SIEMENS –Germany is with ordering code
Interlocking (6MD6631-4EB90-0AA4+L0S) shall be used.
Supervision & Monitoring Functions:
CT supervision Protection IEDS: From Manufacturers listed in
74TC section 15 of the data base of Approved
WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
ofdirect material supply order), as confirmed,
through their letter # EA PRO/Pz, dated April 22,
014 shall be applicable for all (SIPROTEC 5
Relays) to be supplied to SEC/National Grid SA.
SPRECHER AUTOMATION GMBH ALFANAR ELECTRICAL up to 380KV 1. For Bay Controller Based on the S & SD fax #
AUSTRIA SYSTEMS Saudi Arabia Unit (BCU) type 16-08451-02-30504401 dated 16/11/2016
Plant -3Rd Industrial 1. For Bay Controller Unit (BCU) type Sprecon –E-C-96 Sprecher Automation GmbH –Austria with
Plant -Franckstrabe 51,4018 Linz, Zell Area, Al Sprecon –E-C-96 from SPRECHER – from SPRECHER – Integration and FAT at Al-Fanar Electrical System
am See & Vienna in Austria Kharaj Road, Riyadh AUSTRIA: AUSTRIA: –Riyadh K.S.A for Substation Automation
Saudi Arabia Sprecon E-C-96 BCU with ABTS/ACSE ALFANAR System- SAS up to 380KV is prequalified against
Contact Person - Mr. Peter Wach –Area Po Box 301 , Riyadh & ACCS Control Functions ELECTRICAL TES-P-107.01, Rev.00, with the following
Sales Manager 11411 , North SYSTEMS conditions:
Contact Person Email ID - Righ Road Between Exit successfully
peter.wach@sprecher-automation.com 5&6 completed type tests Type Tests: The manufacturer has confirmed to
Riyadh , Saudi Arabia on sprecon E-C-96 perform the required type tests in SEC/National
Contact Person - Mr. BCU based Grid SA approved Independent Testing laboratory
Samer Y. Mokdad , ABTS/ACSE & as per SEC/National Grid SA requirements , IEC
Executive Manager. ACCS Control 61850 Edition 2 standards in the presence of
Email: Functions Ref. three (3) SEC/National Grid SA Engineers and one
samer.mokdad@alfanar. #20-2141, Rev. (1) Independent Inspector through reference
com dated 07.02.2020, in letter dated 24/10/2016 , ref#
ashraf.mohamed@alfan KEMA – Netherland AES-SAS-PQA-2016/008.
ar.com Laboratory
Phone - Guarantee/Warranty: The manufacturer (Both
+966-540339574 Sprecher & Al-Fanar) has agreed to give
guarantee/ warranty to SEC/National Grid SA for
the proposed Substation Automation System
(SAS) from SPRECHER Automation GmbH
-Austria with Integration and FAT at AL-FANAR
ELECTRICAL SYSTEM –Riyadh K.S.A in respect
of the defects due to design, manufacturing,
installation and workmanship for a period of ten
(10) years , This was confirmed in writing by the
manufacturer through their letter for SAS.
PQ Letter
WARRANTY
System House Factory for Electrical SAS Software: Latest version of PQ Letter
Panels (SEP)-Riyadh Zenon SAS Software from
Saudi Arabia COPA-DATA Based on S&SD letter # 19-03431-30504401
dated November 26, 2019, SYSTEM HOUSE
Plant -Saudi Aribia - Riyadh SAS Hardware: Shall be from latest FACTORY, Riyadh – Saudi Arabia is prequalified
version of List of Technically for Substation Automation System Integrator for
Plant -New Industrial Area No:1, Riyadh Acceptable Manufacturers (LOTAM) Substation up to 132kV as confirming to National
Grid SA specification # TES-P-107.01, with the
Riyadh SAS Design: Approved SAS following conditions:
Standardization Design from National
Contact Person - Mr. Bruno Stocchi Grid SA Committee WARRANTY
Contact Person Email ID -
majed@sep.com.sa, Ten (10) years extended warranty from the date
bruno@sep.com.sa of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their Letter No. SAS/W-19-001-R1 dated
August 28, 2019 shall be applicable for the
equipment to be supplied to SEC/National Grid SA.
Hitachi Energy Switzerland Ltd. Hitachi Energy Mfr. Name change from ABB SWITZERLAND LTD.
SWITZERLAND Hitachi Energy Ltd. ( GLOBAL SAS CENTER) to Hitachi Energy
Riyadh, Saudi Arabia Switzerland Ltd.
Plant -switzerland Phone: +966 11 2181703
Mobile: +966 500414555 Old remarks:
Bruggerstrasse 72, 5400 Baden
PQ Lettter
Contact Person - Mr. Ahmed Abubasha, Based on S&SD letter# 14-00953-1-30504401
Mr. Abdulmajeed Alothman dated February 27, 2014, ABB Switzerland Ltd.(
Phone - +41 58 588 33 50 Global SAS Center), Baden, Switzerland is
Email ID - pre-qualified for Engineering, integration and
Ahmed.abubasha@hitachienergy.com, testing of SAS systems for substations up to 380
abdulmajeed.alothman@hitachienergy.c kV against specification # TES-P-107.01, Rev.00
om with the following conditions:
Contact Person Email ID -
Ahmed.abubasha@hitachienergy.com, CONDITION
abdulmajeed.alothman@hitachienergy.c Type test shall be conducted in independent
om testing laboratory for the SAS System as per
Website - www.hitachienergy.com National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Total = 10
NEST OY/NAPS
FINLAND
Total = 1
ATOFINA CHEMICALS
United States
Website - http://www.atofina.com
Website -
http://www.dielectrictechnologies.com/
index.html
INDOPOL
FRANCE
Lavera , France
Website - http://www.indopol.com/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
SIEMENS
GERMANY
Total = 5
DC POWER SYSTEMS
37. 1
DC POWER SYSTEMS Applicable Standards:
EXIDE CORP.
United States
Pa , United States
Website - http://www.exide.com/
Website -
http://www.harmerandsimmons.com/
Website -
http://www.powersupplysystems.com/
index2.htm
Total = 4
NERA
NORWAY
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Turgi , France
Website - http://www.abb.fr/
Website - http://www.ge.com/
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
AREVA
FRANCE
Total = 6
Montreal,Canada
Total = 1
VF INTERFACE EQPT.
40. 1
VF INTERFACE EQPT. Applicable Standards:
Turgi , Switzerland
Website - http://www.abb.ch/
TELLABS INC.
United States
Website - http://www.tellabs.com/
Total = 2
ELECTRONIA
Saudi Arabia
Website - http://www.electronia.com/
GE/ERICSON
United States
GLENAYRE ON HOLD
CANADA
Bc , Canada
Website - http://www.glenayre.com
KENWOOD
United States
Website -
http://www.kenwoodusa.com/
MOTOROLA
United States
Website -
http://www.motorola.com/us/products.j
sp
NEC
United States
Website - http://www.nec.com/
NOKIA
FINLAND
Website - http://www.nokia.com/
PHILIPS
United Kingdom
Website -
http://www.philips.co.uk/index.page
Total = 8
TEST EQUIPMENT
42. 1
TEST EQUIPMENT Applicable Standards:
ACTERNA
United States
Website - http://www.acterna.com/
Tokyo , Japan
Website - http://www.ando.nl/
Website - http://www.hp.com/
IFR
United States
Website -
http://www2.rohde-schwarz.com/
TREND
SPAIN
Website -
http://es.trendmicro.com/es/home/
PHILIPS
United Kingdom
Website -
http://www.philips.co.uk/index.page
Total = 8
TEST EQUIPMENT
42. 2
TEST EQUIPMENT (FIBER OPTIC RELATED) Applicable Standards: 48-TMSS-14
ANRITSU CORPORATION
JAPAN
Tokyo , Japan
Website - http://www.anritsu.com/
Total = 1
TEST EQUIPMENT
42. 3
TEST EQUIPMENT (RADIO RELATED) Applicable Standards:
BIRD
United States
Website -
http://www.bird-electronic.com/
MARCONI
United Kingdom
Website -
http://mecss.com.sa/contact.html
Total = 2
TEST EQUIPMENT
42. 4
TEST EQUIPMENT (RADIO/PAGING RELATED) Applicable Standards:
NEC
United States
Website - http://www.nec.com/
Total = 1
TEST EQUIPMENT
42. 5
RADIO/PAGING EQUIPMENT (ACCESSORIES) Applicable Standards:
ALLEN
United States
ANDREW
United States
Il , United States
Website - http://www.andrew.com/
CELWAVE
United States
Website - http://www.celwave.com/
DECIBEL
United States
FLEXWELL
United States
JAYBEAM
United Kingdom
Website -
http://www.jaybeamwireless.com/inde
x.php
Website - http://uk.rs-online.com/web/
Total = 8
UHF RADIO
43. 1
UHF RADIO Applicable Standards:
ASCOM
United Kingdom
Website -
http://www.ascom.co.uk/uk-en
SIMOCO
United Kingdom
Website -
http://www.simoco.com/index.php
ALCATEL
FRANCE
Website - http://www.alcatel.fr/
Total = 3
NOKIA
FINLAND
Website - http://www.nokia.com/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
NORTEL ON HOLD
CANADA
Website - http://www.nortel.com/
Total = 3
JANUS FIRE SYSTEMS Mr. John Parker CO2 UL Listed The manufacturer is added based on
United States + 9733888644 Low pressure & High Pressure confirmation by Industrial Security Sector
john.parker@amerex-fire Systems /Industrial Security Performance Department
1102 Rupccih Drive .com Manager as per email message of
Millennium Park January,16,2017”.
Crown point ,IN 46307
“ Janus Fire Systems, USA, has agreed to give
Telephone :219.663.1600 Guarantee/ Warranty to SEC/ National Grid SA
Fax : 219.663.4562 vide letter # Nil, dated April 07, 2017, for the
proposed Fire Fighting System-High Pressure
Contact Person - Barry Cornel Carbon Dioxide (CO2) in respect of the defects
Email ID - due to design and manufacturing for a period of
bcornell@janusfiresystems.com ten (10) years from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) or from date of delivery
for the direct material supply order. The
guarantee/ warrant shall be applicable for the
first project and shall subsequently be reduced
yearly in case of future project award
NAFFCO NAFFCO UL listed Co2 extinguisheres ,model UL listed The manufacturer is added based on
United Arab Emirates PO BOX 67716 RIYADH 451,456,466, C -50-SE ,and C-100-SE. LPCB approved UL confirmation by Industrial Security Sector
11517 UL listed Dry Chemical Extinguishers listed Fire /Industrial Security Performance Department
NAFFCO, P.O Box :17014, Dubai, TEL : 0112824444 Wheeled type. Extinguishers ,and Manager as per email message of
United Arab Emirates. 'Sathiskumar@naffco.co LPCB Mobile Fire Extingishres. LPCB/BSI approved January,16,2017”, and April 24, 2017
m'; Fire Extinguishers
Tel :- # 97148066666 'ksa.est1@naffco.com'
Fax: # 971 48816229
Dubai
Website - http://www.kiddeus.com/
Website -
http://www.atd-cardox.com/atd-cardo
x-vertretungen.htm
Website -
http://www.chemetron.com/utcfs/Temp
lates/Pages/Template-46/1,8060,pageId
=1192&siteId=374,00.html
FIKE
United States
Website - http://www.fike.com/
HYGOOD
United States
Website -
http://www.hygood.co.uk/default.asp
Total = 7
GRINNEL
United States
Website - http://www.grinnell.com/
Website -
http://www.reliablesprinkler.com/
SPRAYSAFE
United States
Website -
http://www.centralspraysafe.com/cgi-
bin/webscripts/nph-home.pl
Website -
http://www.vikingrange.com/consumer
/index.jsp
WATTS
United States
Website - http://www.watts.com/
Total = 5
Viking GmbH & Co. KG Advanced Elements for FM200 System: UL/FM/VdS The manufacturer is added based on
GERMANY Fire Protection Systems Model VSN200 @ 25, 42& 50 bars UL/FM/VdS confirmation by Industrial Security Sector
Tel: 0114722799 /Industrial Security Performance Department
INDUSTRIESTRASSE 10/12 Manager as per email message of
23480 BAD OLDESLOE, GERMANY January,16,2017
FIRETRACE Guarantee Business FM200 System: UL & ULC listed The manufacturer is added based on
United States Contracting Est Models,01-001372,01-001407, confirmation by Industrial Security Sector
KSA – P.O Box 26018 01-001487,01001587,01-001712,01-00 /Industrial Security Performance Department
USA L L C EX15893 Riyadh 1897,01-002537 all @360 psig (25 bar) Manager as per email message of
SUITE 2 0114919669 January,16,2017”.
8435 N 90TH ST
SCOTTSDALE, AZ 85258 USA
Middle East, North Africa & Caspian
SIEX Engineering Field Est. 1) SIEX –HC 227 (25 & 24 bar). UL Listed FM The manufacturer is added based on
SPAIN Phone : 02-6579028 2) SIEX –HC227 S- Flow (32.34.50.& approved. confirmation by Industrial Security Sector
Fax : 026579028 55 bar) /Industrial Security Performance Department
2001 SL Agil Alattas Manager as per email message of
POL INDUSTRIAL VILLAONQUEJAR info@ef.com.sa January,16,2017
C/MERINDAD DE MONTIJA NO 6
09001 BURGOS,SPAIN
Fike Corporation NAFFCO Fike UL /FM approved FM 200 UL Listed FM The manufacturer is added based on
United Arab Emirates PO BOX 67716 RIYADH Using Fike impulse Valve with burst approved confirmation by Industrial Security
11517 disc Sec-or/Industrial Security Performance
Plant -Dubai Gulf Star Security & Department Manager per email mess-age of
Safety Jan-uary,16,2017”, and April 24, 2017.
Sheikh Zayed Road P.O Box 125917 Head office ,2nd floor ,Al
kaaf Al Akhdr Bldb,
Steen street , Jeddah
Al-Sarh Al-Methali
Trading
6th street ,off 95th
street. 2nd industrial City
Dammam
TEL : 0112824444
SIEMENS BUILDING TECHNOLOGIES – Siemens Ltd. Sinorix 227 (360 PSI) Fire Extinguishing UL Listed The manufacturer is added based on
FIRE SAFETY Business Gate, P.O. Box System. confirmation by Industrial Security Sector
United States 9510, 11423 Riyadh, •The gas is identified as:UL scope of fil /Industrial Security Performance Department
Saudi Arabia EX6288, SHANGHAI Waysmos Fine Manager as per email message of
SIEMENS INDUSTRY INC EX4724 Chemical Co Ltd (DBA Waysmos USA, January,16,2017”.
8 Fernwood Rd Tel +966 (11) 277 8208, Product tradename MH227),388 Liangle
Fax +966 (11) 277 8497, Rd, Laogang Town Pudong New
Florham Park, NJ 07932-1906 USA Mobile +966 (54) 335 District 201322 Shanghai, CHINA
0691, +966 (54) 346
3238
ashfaq.abdul-jabbar@si
emens.com
DUPONT
United States
GREAT LAKES
United States
Total = 8
MINIMAX PQ Lettter
GERMANY Based on S&SD Letter 12-02704-02-30504001
dated February 19, 2012. It is pre-qualified for
Bad Oldesloe , Germany Fire Protective Signaling Panel as conforming to
SEC Specification # 90-TMSS-01 Rev.0
CONDITION
All Type, Routine and Special testes shall be
carried out on the first batch of Fire Protective
Signaling Panel in an Independent Testing
Laboratory in the presence of three (3) SEC
Engineers & one (1) SEC approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil dated January 11, 2011.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2011.
FENWAL
United States
FIGGIE
United States
FIREATER
United States
KIDDE
United States
Website - http://www.kiddeus.com/
Website -
http://www.chemetron.com/utcfs/Temp
lates/Pages/Template-46/1,8060,pageId
=1192&siteId=374,00.html
FIKE
United States
Website - http://www.fike.com/
HYGOOD
United States
Website -
http://www.hygood.co.uk/default.asp
Website - https://
http://www.ansul.com/en/home.asp
Total = 10
JANUS FIRE SYSTEMS Mr. John Parker Novec1230 System: UL Listed “The manufacturer is added based on
United States Ph: + 9733888644 Sv, Mv and Lv Series confirmation by Industrial Security Sector
E Mail: /Industrial Security Performance Department
1102 Rupccih Drive john.parker@amerex-fire Manager as per email message of
Millennium Park .com January,16,2017”.
Crown point ,IN 46307 Janus Fire Systems, USA, has agreed to give
Guarantee/Warranty to SEC/National Grid SA vide
Telephone :219.663.1600 letter # Nil, dated April 07, 2017, for the proposed
Fax : 219.663.4562 Fire Fighting Systems-Novec 1230 Fluid
(F-K-1-12 Dodecafluoru-2-methylpentan-3-one
Contact Person - Barry Cornel CF2CF2C(O)CF(CF3)2) in respect of the defects
Email ID - due to design and manufacturing for a period of
bcornell@janusfiresystems.com ten (10) years from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) or from date of delivery
for the direct material supply order. The
guarantee/warrant shall be applicable for the first
project and shall subsequently be reduced yearly
in case of future project award.
Viking GmbH & Co. KG Advanced Elements for Novec1230 System: UL/FM/VdS The manufacturer is added based on
GERMANY Fire Protection Systems Model VSN1230 @25, 42 &50 bars. UL/FM/VdS confirmation by Industrial Security Sector
Tel: 0114722799 /Industrial Security Performance Department
INDUSTRIESTRASSE 10/12 Manager as per email message of
23480 BAD OLDESLOE, GERMANY January,16,2017”.
FIRETRACE Guarantee Business Novec1230 System: UL & ULC listed The manufacturer is added based on
United States Contracting Est Models : 01-001352, confirmation by Industrial Security Sector
KSA – 01-001366,01-001399, /Industrial Security Performance Department
USA L L C EX15893 P.O Box 26018 01-001440,01-001490, Manager as per email message of
SUITE 2 Riyadh 01-001564,01-001705,01- January,16,2017”.
0114919669 0011827 all @34 bar
8435 N 90TH ST
SCOTTSDALE, AZ 85258 USA
Middle East, North Africa & Caspian
SFFECO 3M Novec 1230 Fire protection UL Listed FM The manufacturer is added based on
Saudi Arabia Extinguishing system units having approved. confirmation by Industrial Security Sector
nominal ging capacitiec of Multiple Listing with /Industrial Security Performance Department
2ND INDUSTRIAL AREA 38,65,,130,2277,and 895 lb @ 25 bar. SEVO Manager as per email message of
AL-KHARJ RD Design & installation per Sevo VDS January,16,2017”.
PO BOX 58469 software Novec –Calculationprogram.
RIYADH, 11515 SAUDI ARABIA
Total = 4
AUTOCALL (GRINNEL)
United States
EDWARDS ON HOLD
CANADA
MIRETONE
United States
Website -
http://www.simplexgrinnell.com/
THORN
United Kingdom
Website -
http://www.thornlighting.co.uk/gb/en/in
dex.htm
SHIELD FIRE SAFETY & SECURITY LTD NAFFCO Extinguishing Control panel mpdel A-Xt. UL Listed FM The manufacturer is added based on
United Kingdom PO BOX 67716 RIYADH Poto –Electric smoke detector model S approved. confirmation by Industrial Security Sector
11517 C2011 /Ind-ustrial Sec-urity Perform-ance Depart-ment
SHIELD FIRE SAFETY & SECURITY LTD TEL : 0112824444 Heat Detector S-C2013 Standard Mana-ger as per email mess-age of
S25191 Eng Selva. mounting base S-c2001Abort switich Jan-uary,16,2017”
REDBURN HOUSE S111R AB
2A TONBRIDGE ROAD Fire Alarm Bell FB-1000C6
ROMFORD, ESSEX RM3 8QE UNITED
KINGDOM
Hochiki America Corporation Engineering Field Est. Addresable (Fire net seies ) & UL Listed FM The manufacturer is added based on
United States Agil Alattas Conventional (HCA seies)Fire Alarm & approved. confirmation by Industrial Security Sector
Phone : 02-6579028 Detection Systems :- /Industrial Security Performance Department
7051 Village Drive, Suite 100 Buena Fax : 026579028 • Fire Control Panels. Manager as per email message of
Park, CA 90621-2268 info@ef.com.sa • Gas Extinguishing Control Panels. January,16,2017”.
• Fire Detection & Alarm Devices.
Phone - Phone : 714/522-2246
Email ID -
technicalsupport@hochiki.com
Website - WWW.Hochiki.com
Total = 9
Website - http://www.aurora.com/
FAIRBANK MORSE
United States LOCAL AGENT –SAUDI PUMP >=500GPM
Website -
http://www.fairbanksmorse.com/
FLOWAY
United States
Website -
http://www.weiroilandgas.com/weirw
eb/oilandgas/home.nsf
Website -
http://www.peerlesspump.com/
PETTERSON
United States
Website -
http://www.ie.pattersonpumps.com/
REDDY BUFFALOU
United States
Website - http://www.rbpump.com/
Website -
http://www.worthington-biochem.com/
Illinois
Saudi Mechanical Industries Co. Saudi Mechanical - Vertical Turbine Fire Water Pump PQ Letter
Saudi Arabia Industries Co. – rating up to 2500 GPM. Based on S&SD letter# 20-01597-30504401
Street No. 234, Second - Split Case Fire Pumps – rating up dated September 06, 2020, the manufacturer is
Plant -Riyadh – Saudi Arabia Industrial City. to 7500 GPM prequalified for FIRE WATER PUMPS as
P.O. BOX 59799 RIYADH - End Suction Fire Pumps – rating confirming to National Grid SA specification #
Street No. 234, Second Industrial City. 11535 up to 750 GPM 90-TMSS-02, with the following conditions:
P.O. BOX 59799 RIYADH 11535 00966 11 265 1979 WARRANTY
alaa@smi.com.sa • (10) years Extended Warranty shall be
Riyadh applicable for the offered FIRE WATER PUMPS to
be supplied to SEC/National Grid SA as confirmed
Contact Person - Alaa Alkhatatbeh through Letter # Nill dated Nill.
Phone - 00966 11 265 1979 Type Test
Email ID - alaa@smi.com.sa • All type tests for SVC (TCR/TSC) supplied to
Contact Person Email ID - SEC shall be conducted in presence of three (3)
alaa@smi.com.sa SEC/National Grid SA engineers & one (1) SEC
Website - www.smi.com.sa approved independent inspection agency
Inspector, all the related costs for witnessing the
tests will be borne by the manufacturer. This
was confirmed by NR Electric Co., Ltd.- China
through their letter # GJYX20200507_XG01,
dated May 07,2020.
• All type tests for Valves Cooling system
supplied to SEC shall be conducted in presence
of three (3) SEC/National Grid SA engineers &
one (1) SEC approved independent inspection
agency Inspector, all the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by NR Electric
Co., Ltd.- China through their letter #
GJYX20200507_XG02, dated May 07,2020.
Total = 9
SFFECO
Saudi Arabia
Total = 2
Website - https://
http://www.ansul.com/en/home.asp
Website -
http://www.sentry-equip.com/display/r
outer.aspx
Website - http://www.kiddeus.com/
Total = 3
Website - https://
http://www.ansul.com/en/home.asp
Website -
http://www.sentry-equip.com/display/r
outer.aspx
Total = 2
Website -
http://www.sentry-equip.com/display/r
outer.aspx
Total = 1
ANGUS
United Kingdom
Website -
http://www.angusfire.co.uk/utcfs/Temp
lates/Pages/Template-46/0,8060,pageId
%3D1260%26siteId%3D404,00.html
Website - http://www.chemguard.com/
Website -
http://www.kidde-fire.com/utcfs/Templ
ates/Pages/Template-50/0,8061,pageId
%3D3513%26siteId%3D465,00.html
HILTI INTERNATIONAL, Hilti construction Hilti Saudi Arabia P.O FIRESTOP PRODUCTS; UL Listed FM The manufacturer is added based on
chemicals ,Div.of Hilti Inc. box 286701 Firestop Sealants, firestop Foams, approved. confirmation by Industrial Security Sector
United States Riyadh11323 Firestop collars & Wraps ,Firestop /Industrial Security Performance Department
T: 0114608974 Mortars & Boards, Firestop cast in Manager as per email message of
5400 122nd East Ave Fax: 0114606255 Devices ,Firestop Blocks ,Plugs January,16,2017”.
Tusla ,OK 74146 Mobile : 0504657548 ,Cushions. Fire Protection Coatings &
abusheikha@ hilti.com Fire stop Transit Systems.
WWW.hilti.sa
Total = 4
HVAC Units
47. 1
HVAC Units Applicable Standards: 73-TMSS-01
TRANE
Saudi Arabia
PETRA
JORDAN
Total = 7
Total = 5
Total = 2
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
WESCOSA
Saudi Arabia
Saudi Arabia
Total = 3
Geneva, Switzerland
Website - http://www.pauwels.com/
Total = 2
ABB ( T& D)
United States
Website - http://www.abb.us/
Total = 1
SIEMENS PQ Letter:
Saudi Arabia Based on S&SD letter # 14-08957-02-30504401
dated 17 December 2014, the manufacturer is
Plant -Jeddah prequalified for Integration (Assembly) and
Testing of Communication Equipment from
Website - http://www.siemens.com.sa Original Equipment Manufacturer (OEM) type
tested and approved by National Grid SA as
conforming to National Grid SA specification #
48-TMSS-06, Rev.0 with the following condition:
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Fe/08/14 dated October 10, 2012.
SYSTEM HOUSE FACTORY FOR Local Mfr. Only OEM prequalified Telecom OEM type tested PQ Letter
ELECTRIC PANELS (SEP,) located at Unit No. 45, equipment for which care services Telecom equipment
Saudi Arabia Street 201 Second (Managed Services) agreement has and approved by Based on S&SD Letter # MPQ884220352-Class
Industrial City Building been signed by SEP with OEMs for SEC/National Grid I(a)-2020 dated September 28, 2022, the
Plant -New Industrial Area No:1, Riyadh No. 6687, Riyadh 14431 future firmware and soft/hardware SA . manufacturer is prequalified as
+966 11 4980822 Ext upgradation or any technical support Telecommunication Integration facilities only for
P O Box 355950, New Industrial Area 601 required in future for particular telecom integration (assembly) & testing of Telecom
No:2, Riyadh -11383 muhannad.ali@sep.com. equipment to be integrated (assembled) equipment from original equipment manufacturer
sa bruno@sep.com.sa and Tested, and staff is certified (OEM) type tested and approved by SEC/National
Contact Person - Mr. Bruno Stocchi trained for the particular Telecom Grid SA as conforming to National Grid SA
Phone - +966- 0535754302 , +966- equipment by OEM. relevant Telecom equipment specification with the
0505278491 following conditions:
Email ID - E-mail majed@sep.com.sa,
bruno@sep.com.saMajed Aburajab, Warranty:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order) as confirmed,
through their letter No.
SEP-Telecom-0003-PQ-20-08, dated August 12,
2020, shall be applicable for the equipment to be
supplied to SEC/National Grid SA.
Hitachi Energy Ltd. Previous name was ABB Contracting Co. Ltd. ,
Saudi Arabia and changed to Hitachi Energy Ltd.
Plant -2Nd Industrial Area,Riyadh, Previous name was ABB Electrical Industries
Company Ltd, and changed to ABB Contracting
Po Box 325841 Riyadh,11371 KSA Co. Ltd based on S&SD letter
#20-01681-30504401 dated October 01, 2020
Contact Person - Mr. Essam
Bashraheel & Mr. Ahmed Abubasha
Phone - Tel:+966-011-476-2644
Fax:+966-011-476-9622 PQ Letter
Contact Person Email ID - Based on S&SD letter # 15-01367-01-30504401
Essam.bashraheel@hitachienergy.com dated 8th March-2015, the manufacturer is
& prequalified for ‘Integration (Assembly) & Testing
Ahmed.Abubasha@hitachienergy.com of Communication & SCADA Equipment from
Original Equipment Manufacturer (OEM) type
tested & approved by SEC/National Grid as
conforming to National Grid SA specification #
48-TMSS-06, Rev.0 with the following condition:
WARRANTY:
• Ten (10) years extended warranty in respect of
the defects due to design, manufacturing and
workmanship, as confirmed by the manufacturer
through their letter # PSN/TLE/0517/09/2014,dt:
15/09/2014.
Total = 4
NR Electric Co., Ltd. Control Systems PCS-9580 & PCS-9510 To be conducted PQ Letter
CHINA Company during first project Based on S&SD letter# 20-01464/01-030504401
3364 Umar Ibn Abdul dated August 19, 2020, the NR Electric Co., Ltd. -
Plant -Nanjing, China Aziz Rd Az Zahra, China is prequalified for Static Var Compensator
Unit No 6, Ar Riyadh (SVC) System PCS-9580 & Valves Cooling
69 Suyuan Avenue, Nanjing 211102, 12815 6238, System PCS-9510 as confirming to National Grid
China Kingdom of Saudi Arabia SA specification # 59-TMSS-01 & 59-TMSS-02,
+ 966 11 408 8010 with the following conditions:
Nanjing mazin.alabad@CSCH.CO
M.SA WARRANTY
Contact Person - Li Xueguang • Ten (10) years Extended Warranty shall be
Phone - +86 25 8717 8888 applicable for the offered SVC (TCR/TSC Valves)
Email ID - Sales@nrec.com System to be supplied to SEC/National Grid SA as
Contact Person Email ID - confirmed through Letter #
lixg@nrec.com GJYX20200507_LXG03 dated May 07,2020.
Website - www.nrec.com • Ten (10) years Extended Warranty shall be
applicable for the offered Valves Cooling System
to be supplied to SEC/National Grid SA as
confirmed through Letter #
GJYX20200507_LXG04 dated May 07,2020.
Type Test
• All type tests for SVC (TCR/TSC) supplied to
SEC shall be conducted in presence of three (3)
SEC/National Grid SA engineers & one (1) SEC
approved independent inspection agency
Inspector, all the related costs for witnessing the
tests will be borne by the manufacturer. This
was confirmed by NR Electric Co.,- Ltd.- China
through their letter # GJYX20200507_LXG01,
dated May 07,2020.
• All type tests for Valves Cooling system
supplied to SEC shall be conducted in presence
of three (3) SEC/National Grid SA engineers &
one (1) SEC approved independent inspection
agency Inspector, all the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by NR Electric
Co., Ltd.- China through their letter #
GJYX20200507_LXG02, dated May 07,2020.
Others
Total = 1
TYPE TESTS
Manufacturer through Letter No.
GJYX20200622_LXG01 dated June 22,2020 and
Letter No. GJYX20200507_LXG02 dated May
07,2020 confirmed in writing to conduct the type
tests during first project in presence of three (3)
SEC/National Gris SA Engineers and one (1)
SEC/National Grid SA approved inspector. All the
cost pertaining to the type tests shall be borne by
the manufacturer.
Total = 2