You are on page 1of 2

Electro-hydraulic

01_1 st Headline_36 pt/14.4 mm Intelligent pump control systems


HS5 HS5E Bosch Rexroth AG
Zum Eisengießer 1
97816 Lohr, Germany

second
control systems
line provide power on demand
Phone: +49(0)9352/18-0
Fax: +49(0)9352/18-40
info@boschrexroth.de
www.boschrexroth.com

Optimum power density, impact and overload robustness, force


Product overview
maintenance without consuming energy ... hydraulics have many physical
For your local contact, please refer to:
www.boschrexroth.com/contact advantages. With a broad range of control systems, Rexroth taps into state-
of-the-art automation for hydraulic drives. With our experience and our
1X 1X
expertise, we provide quick, flexible and reliable solutions.
A4VSO; VBO; VHO; VSG; CSG A4VSO; VBO; VHO; VSG; CSG
630 630
HFD HFA, HFB, HFC HFD HFA, HFB, HFC
40 71 125 180 250 355 500 750 1000 40 125 500 40 71 125 180 250 355 500 750 1000 40 125 500
60 107 186 270 375 533 750 1125 1500 60 186 750 60 107 186 270 375 533 750 1125 1500 60 186 750
– – – – – – – – – – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – – – – –
4WRPH6…855 On request

yes yes
yes yes
yes yes
yes yes
yes yes
yes yes
The data and properties specified in this brochure only
On request On request
serve to provide a general overview of the "Electro-
yes yes
hydraulic control systems" product range of
yes yes
Bosch Rexroth AG.
yes yes
yes yes
The overview does not include all technical data and
yes yes
variants and does not replace a technical data sheet.
yes yes
Detailed information on the individual valves can be found
yes yes
in the corresponding data sheets.
Digital module VT-HPC (IP20) Digital on-board control electronics (IP65)
recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272) No statements concerning a certain condition or suitability
3 x freely configurable 1 x freely configurable for a certain application can be derived from our
up to 4 x freely configurable up to 3 x freely configurable information.
5 x – freely configurable and switchable (U/I) 5 x – freely configurable and switchable (U/I)
2 x freely configurable 2 x freely configurable The information given does not release the user from the
obligation of own judgment and verification.
analog, digital IO analog, digital IO Document no.: RE 08064
sercos, PROFINET, EtherCAT, POWERLINK, EtherNet/IP, Profibus sercos, PROFINET, EtherCAT, POWERLINK, EtherNet/IP Material no.: R999001304
Version no.: 2016-09
IndraWorks DS IndraWorks DS © Bosch Rexroth AG 2016
Subject to change without notice!
-20 … +60 -20 … +60
30237 92076
www.boschrexroth.com/HPC www.boschrexroth.com/HPC
SYDFE1 SYDFEE SYDFEC/n SYDFED SYHDFEE SYHDFEC/n SYHDFED

Component series 2X 3X 2X 3X 2X 3X 2X 3X 1X 1X 1X
Basic pump A10VSO; component series 31 A10VSO; component series 32 A10VSO; component series 31 A10VSO; component series 32 A10VSO; component series 31 A10VSO; component series 32 A10VSO; component series 31 A10VSO; component series 32 A4VSO A4VSO A4VSO
Operating pressure in bar 280 280 280 280 350 350 350
Hydraulic fluid HL, HLP HL, HLP HL, HLP HL, HLP HL, HLP HFC HL, HLP HFC HL, HLP HFC
Hydraulics

Size 18 28 45 71 100 140 45 71 100 140 180 18 28 45 71 100 140 45 71 100 140 180 18 28 45 71 100 140 45 71 100 140 180 18 28 45 71 100 140 45 71 100 140 180 40 71 125 180 250 355 40 125 180 250 355 40 71 125 180 250 355 40 125 180 250 355 40 71 125 180 250 355 40 125 180 250 355
Maximum flow n = 1500 min-1 27 42 68 107 150 210 68 107 150 210 270 27 42 68 107 150 210 68 107 150 210 270 27 42 68 107 150 210 68 107 150 210 270 27 42 68 107 150 210 68 107 150 210 270 60 107 186 270 375 533 60 186 270 375 533 60 107 186 270 375 533 60 186 270 375 533 60 107 186 270 375 533 60 186 270 375 533
in l/min with nmax /vg max 59 84 117 156 200 252 135 181 230 308 324 59 84 117 156 200 252 135 181 230 308 324 59 84 117 156 200 252 135 181 230 308 324 59 84 117 156 200 252 135 181 230 308 324 104 156 225 324 475 603 104 225 324 375 533 104 156 225 324 475 603 104 225 324 375 533 104 156 225 324 475 603 104 225 324 375 533
Maximum speed nmax 3300 3000 2600 2200 2000 1800 3000 2550 2300 2200 1800 3300 3000 2600 2200 2000 1800 3000 2550 2300 2200 1800 3300 3000 2600 2200 2000 1800 3000 2550 2300 2200 1800 3300 3000 2600 2200 2000 1800 3000 2550 2300 2200 1800 2600 2200 1800 1800 1900 1700 2600 1800 1800 1500 1500 2600 2200 1800 1800 1900 1700 2600 1800 1800 1500 1500 2600 2200 1800 1800 1900 1700 2600 1800 1800 1500 1500
High-response valve VT-DFP-2X VT-DFPE-2X VT-DFPn-2X VT-DFPD-1X VT-DFPE-2X VT-DFPn-2X VT-DFPD-2X
Swivel angle sensor LVDT (IW9) Analog (VT-SWA-1-1X/DFEE) Analog (VT-SWA-1-1X/DFEE) Analog (VT-SWA-1-1X/DFEE-G15) Analog VT-SWA-LIN-1X/G10-x-K44 Analog VT-SWA-LIN-1X/G10-x-K44 Analog VT-SWA-LIN-1X/G15-x-K44

Swivel angle control yes yes yes yes yes yes yes
Flow control yes yes yes yes yes yes yes
Pressure control yes yes yes yes yes yes yes
pQ controller yes yes yes yes yes yes yes
Power limitation yes yes yes yes yes yes yes
Operating modes

Master/slave yes yes yes yes yes yes yes


Hydro Gear (n calculation) no no yes On request No yes On request
2-quadrant operation yes yes yes yes yes yes yes
4-quadrant operation no no no no no no no
Switchable pressure controller (V adjustment) yes yes yes yes yes no yes
Leakage compensation yes yes yes yes yes yes yes
Automatic calibration no no yes yes no yes yes
Parameter set switch-over no no yes yes no yes yes
Condition monitoring no no no yes no no yes

Control electronics Analog circuit board VT5041 (IP20) (data sheet 30242) Analog on-board control electronics (IP65) Digital on-board control electronics (IP65) Digital on-board control electronics (IP65) Analog on-board control electronics (IP65) Digital on-board control electronics (IP65) Digital on-board control electronics (IP65)
Pressure sensor recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272) recommended HM20-2X (data sheet 30272)
Electronics

Digital outputs 3 x – fault message, power limit active, swivel angle controller active 2 x – fault message, performance limit active Fault message 1 x freely configurable 2 x – fault message and performance limit active Fault message 1 x freely configurable
Digital inputs 3 x – enable, switch TD and Master/Slave Volume adjustment or pressure controller off 3 x – variants or parameterization option up to 3 x freely configurable 1 x – volume adjustment or pressure controller off 3 x – variants or parameterization option up to 3 x freely configurable
Analog inputs 4 x – fixed functionality 4 x – fixed functionality 4 x – variants or parameterization option 5 x – freely configurable and switchable (U/I) 4 x – fixed functionality 4 x – variants or parameterization option 5 x – freely configurable and switchable (U/I)
Analog outputs Actual swivel angle value and actual pressure value Actual swivel angle value and actual pressure value 2 x – variants or parameterization option 2 x freely configurable Actual swivel angle value and actual pressure value 2 x – variants or parameterization option 2 x freely configurable

Analog analog, digital IO analog, digital IO analog, digital IO analog, digital IO analog, digital IO analog, digital IO analog, digital IO
Interface

Bus systems – – CANopen sercos, PROFINET, EtherCAT, VARAN, POWERLINK, EtherNet/IP – CANopen CANopen
Software parameterization/diagnosis – – – WIN PED 5.10 IndraWorks DS – WIN PED 5.10 sercos, PROFINET, EtherCAT, VARAN, POWERLINK, EtherNet/IP

Ambient temperature in °C 0 … +50 (VT5041); -20 … +60 (pump) 0 … +60 0 … +50 0 … +50 0 … +60 0 … +50 0 … +50
Info

Data sheet 30030 30630 30030 30630 30030 30630 30030 30630 30035 30035 30035
Internet www.boschrexroth.com/SYDFE www.boschrexroth.com/SYDFE www.boschrexroth.com/SYDFE www.boschrexroth.com/SYDFE www.boschrexroth.com/SYDFE www.boschrexroth.com/SYDFE www.boschrexroth.com/SYDFE

You might also like