Actuator-Sensor-Interface Baumer electric

AS-Interface module
ASIA 56A2219
Art.-Code: 156037
82
• Specification 2.11
41 44,5
• Standard addressing mode as mounting module base
ø 4,4 (2x) 13,3
S-slave; up to 31 modules
• Profile S - 3.0.F

EXT
35 (DIN rail)
• Address programming via jack add. cable nut

56

38
44

BUS
bus cable

max. 75
• Power supply for two 2- or 3-wire

EXT
energy cable
sensors via bus

6
• External power supply with flat
cables for two actuators
ø 2,8 to 6,0 ø 16 25,5
• Fault diagnosis LED‘s
20 20 20
• Output diagnosis feedback
bus data connection diagram
voltage supply range 26,5 - 33,1 VDC
supply current ≤ 200 mA
reverse polarity protection yes +
- 1
IN
E/A configuration 3 HEX +
AS-i + D0 - 2
.
ID-code / ID-2 code 0 HEX / F HEX AS-i
.
.
IN
-
AS-i D3
AS-i voltage indicator / error indicator green LED / red LED 0+
0- 3
EX+
inputs 0+
0- 4
EXT+
supply voltage for sensors 18 - 30 VDC EXT -
EX+

short-circuit protection with feedback yes


total current for sensors -25...+40 °C ≤ 170 mA
total current for sensors +40...+70 °C ≤ 130 mA
polarity of the inputs PNP general
input current high / low ≥ 5 mA / ≤ 1,5 mA
input voltage high / low > 11 VDC / < 5 VDC
input indicator yellow LED port assignment:
outputs D0, D1 input
switching element / polarity FET / plus switching (PNP) D2, D3 output
galvanic separation AS-i <> load circuit 2000 VDC
switching current per output Imax 3,3 A possible conductor cross-sections:
total current for outputs sensor terminals: 0,08...2,5 mm2,
4A
actuator terminals: 0,08...2,5 mm2
short-circuit protection / with feedback yes / peripheral error diagnosis LED max. outer cable diameter: ø 2,8...6 mm
watchdog for bus monitoring yes
output indicator yellow LED
external power supply for outputs via separate AS-i flat cable, black diagnosis
voltage range external feed 12 - 30 VDC
max. load inductivity (mH) @ 3,3 A ≤ 25 mH ASI Error
(green) (red)
Status Description

general POWER OFF


Address = 0
no AS-i power
Address = 0
protection class IP 65 (with EPDM cable) no data exchange Watchdog activated,
Address = 0
temperature range / storage temperature -25...+70 °C / -25...+85 °C ok
external RESET,
ok
- Sensor supply overload
overload - Sensor supply shorted
housing material PBT / PC (UL 94 V-0) peripheral error outputs:
- overload / shorted
specification power supply unit for external feed according to PELV
LED dark LED light LED flashing
mounting DIN rail / screws
EMC refer to the AS-i brochure
certificate no. 60308 - A periperal error at the outputs does not
activate a master config. error
- Break of output cables not monitored

Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Technical specifications subject to change
Drawn: 02.05.05/meo Checked: 04.05.05/phw Released: 04.05.05/phw Last change: 23.12.05/phw
Actuator-Sensor-Interface Baumer electric

AS-Interface module
ASIA 56A2222
Art.-Code: 147628
82
• Specification 2.11
41 44,5
• Extended addressing mode as mounting module base
ø 4,4 (2x) 13,3
A/B-slave; up to 62 modules
• Profile S - B.A.0

EXT
35 (DIN rail)
• Address programming via jack add. cable nut

56

38
44

BUS
bus cable

max. 75
• Power supply for two 2- or 3-wire

EXT
energy cable
sensors via bus

6
• External power supply with flat
cables for two actuators
ø 2,8 to 6,0 ø 16 25,5
• Fault diagnosis LED‘s
20 20 20
• Output diagnosis feedback
bus data connection diagram
voltage supply range 26,5 - 33,1 VDC
supply current ≤ 185 mA
reverse polarity protection yes +
- 1
IN
E/A configuration B HEX + +
AS-i D0 - 2
.
ID-code / ID-2 code A HEX / 0 HEX AS-i
.
.
IN
-
AS-i D3
AS-i voltage indicator / error indicator green LED / red LED 0+
0- 3
EX+
inputs 0+
0-
EXT+ 4
EX+
supply voltage for sensors 18 - 30 VDC EXT -

short-circuit protection with feedback yes


total current for sensors -25...+70 °C ≤ 125 mA
polarity of the inputs PNP
input current high / low ≥ 5 mA / ≤ 1,5 mA general
input voltage high / low > 11 VDC / < 5 VDC
input indicator yellow LED
outputs port assignment:
switching element / polarity FET / plus switching (PNP) D0, D1 output
galvanic separation AS-i <> load circuit 2000 VDC D2, D3 input
switching current per output Imax 3,3 A
total current for outputs 4A possible conductor cross-sections:
sensor terminals: 0,08...2,5 mm2,
short-circuit protection / with feedback yes / peripheral error LPF actuator terminals: 0,08...2,5 mm2
watchdog for bus monitoring yes max. outer cable diameter: ø 2,8...6 mm
output indicator yellow LED
external power supply for outputs via separate AS-i flat cable, black
voltage range external feed 12 - 30 VDC diagnosis
max. load inductivity (mH) @ 3,3 A ≤ 25 mH
general ASI Error
(green) (red)
Status Description

POWER OFF no AS-i power


protection class IP 65 (with EPDM cable) Address = 0 Address = 0
temperature range / storage temperature -25...+70 °C / -25...+85 °C no data exchange Watchdog activated,
Address = 0
ok ok
housing material PBT / PC (UL 94 V-0) external RESET, - Sensor supply overload
overload - Sensor supply shorted
specification power supply unit for external feed according to PELV peripheral error outputs:
- overload / shorted
mounting DIN rail / screws LED dark LED light LED flashing
EMC refer to the AS-i brochure
certificate no. 60301
- A periperal error at the outputs does not
activate a master config. error
- Break of output cables not monitored

Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Technical specifications subject to change
Drawn: 03.12.03/rue Checked: 10.02.04/phw Released: 20.04.04/phw Last change: 03.06.05/phw