Professional Documents
Culture Documents
B.I.T Sindri
Requisition for Environmental Engineering Lab
S.No Name of the Specifications Engineerin Estimated
. Intruments g Utility cost(Rs)
1 Water and DISPLAY 3.5 Digit Water and 8000/-
Soil Testing LED Soil
Kits Testing
PH RANGE pH 0 TO
Kits, which
14.00
is a
RESOLUTI pH 0.01 microproce
ON ssor based
ACCURAC measuring
pH 0.01 ±
Y system.
1 Digit
These
TEMP. 0 to 100 systems are
COMP. Deg. C. used for
measureme
ORP RANGE 0 to ± nt of TDS,
1999mV salinity,
RESOLUTI 1mV. Turbidity,
ON diffused
ACCURAC
oxygen,pH,
1mV ± D.O. And
Y Digit. Temperatur
e of water
CONDUCTIVIT 0 to 200M
RANGE Mhos / Cm
and soil
Y:
in 4 ranges.
RESOLUTI 0.1 μ
ON Mhos / Cm
0.5% of
ACCURAC
Range ±
Y
1Dight
0 to 200M
TDS: RANGE Mhos / Cm
in 4 ranges.
RESOLUTI
0.1 ppm
ON
0.5% of
ACCURAC
Range ±
Y
1Dight
TEMP. 5 deg C to
COMP. 55 deg C.
Gold /
SENSOR Sliver
Amperometr
ic Probe.
TEMPERATUR 0 to
RANGE
E: 100Deg.C
RESOLUTI
0.1 Deg.C.
ON
ACCURAC ± 0.2% of
Y range ± 1
digit.
2 Air Quality Oil Mist Water Vapor: CO, CO2, NO + Measures 40000/-
NO2, H2S, SO2 CO, CO2,
Measureme NO +
Mandatory as per Ip: 2.1.1
nt System NO2, H2S,
Ep: 2.1.6
SO2
Bp: 2007
Pressure Regulator: 0 to 10 kg/cm2
Flow meter: 50 to 1500 ml/min
3 SOUND 1. Accuracy : +/- 1.5 dB (under reference The 5000/-
LEVEL conditions) instrument
METER 2. Frequency range : 31.5 Hz to 8.5 KHz s are used
3. Linearity range : 50 dB for
4. Measuring level : 30-130dBA, 35-130dBC
measuring
5. Frequency weighting : A, C
6. Digital display : 5 digits
the noise
Resolution : 0.1dB level in an
Display : 0.5 secretary environme
7. Bar graph : 50dB scale at 1dB step for nt
monitoring current sound pressure level display
period: 50mS
8. Level range : 30-80 dB, 50-100 dB, 60-110
dB, 80-130 dB
9. Over indicate over range : Under indicate less
then lower limit of the range
10. AC output : 0.707 Vrms at FS output
impedance approx 600T
11. DC output : 10mV/dB output impedance
approx 100T
12. Time waiting : Fast/Slow
13. Microphone : ½ inch Electret Condenser
microphone
14. Max : Maximum hold
15. Power supply : 4*AA 1.5V alkaline cells or
DC 6V 100(Maximum) hold
16. Self calibration time : 10 sec (every turn on)
17. Operating temperature : 0°C to 40°C
Operating humidity : 10% to 80%RH
18. Storage temperature : -10°C to 60°C
Storage humidity : 10% to 70%RH
19. Dimension : 265(L)*72(W)*35(H)mm
20. Weight : 300g (including batteries)
21. USB & Data Storage : May record directly
43690 noise data (special user may expand to
131070). May connect with PC through USB,
have functions of data record downloading, real
time data sampling analysis & printing graph &
data etc
4 FLAME DETECT OR PHOTO CELL
To 50000/-
PHOTOME determine
TER FLAME SYSTEM LPG & DRY OIL FREE the
concentrati
on of alkali
POWER SUPPLY 230 VAC +-10%,
and alkaline
FREQUENCY 50 HZ earth metals
in various
samples
5 CO METER Batteries 2 AA batteries To 3000/-
required determine
Material ABS the
Power Source corded-electric level of
Voltage 1 volt carbon
Wattage 1 KW monoxide
Type of Bulb Compact fluorescent
Handle/Lever 1
Placement
Number of Handles 1
Display Style LCD
6 ATOMIC To 12.5 Lakh
ABSORPTI determine
ON of chemical
SPECTROS elements
COPY using the
absorption
of optical
radiation by
free atoms
in the
gaseous
state