DataSheet MicroInversor
This manual contains important instructions to follow during installation and maintenance of the
Microinverter. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the
Microinverter, the following safety symbols appear throughout this document to indicate dangerous
conditions and important safety instructions.
Safety Instructions:
Be aware that the body of the Microinverters is the heat sink and can reach
a temperature of 80 ℃ under extreme conditions. To reduce risk of burns,
do not touch.
Please install the inverter where children can not reach to reduce risk of
shock and burns. Minors and mental patients prohibition use of this
products.
Perform all electrical installations in accordance with all local electrical codes.
Be aware that only qualified personnel should install and/or replace Microinverters.
Connect the Microinverter to the electrical utility grid only after receiving prior approval from the utility
company,and only qualified electrical engineer can perform the operation.
Non-professionals do not disassemble or repair the inverter. If the inverter fails, please contact your
dealer or manufacturer.
Before installing or using the Microinverter, please read all instructions and cautionary markings in the
technical description and on the Microinverter system and the PV-array.
Please install the inverter in ventilated place and away from flammable materials.
Do NOT disconnect the PV module from the Microinverter before removing AC power.
The inverter transform solar photovoltaic (PV) DC power into AC power and fed into the power grid. Do
not use this product for other purposes, for any damage and loss resulting from non-intended use, the
manufacturer / supplier disclaims all responsibility.
2
MaySun-1200W User Manual
1. Product description:
1.1 Appearance and instructions
① ⑦ ②
⑤ ⑥
○
8
③ ④
① PV input(MC4)1
② PV input(MC4)2
③ PV input(MC4)3
④ PV input(MC4)4
⑤ AC input- connect to the previous
⑥ AC output-connect to the next
⑦ LED display
⑧ Item No.
3
MaySun-1200W User Manual
A
B c
D
E F
A:solar panel(PV)
B:MaySun-1200W Microinverter
C:AC cable
D: AC distribution box
E:home utility
F: low voltage utility grid
Description:Connect 4PCS of solar panel to 1pc of MaySun1200W Microinverter. The inverter use
MPPT function to absorb the maximum energy from solar panels, then use high efficiency inverter
conversion to transform the DC to AC, and then use the synchronous high-frequency modulation
and 0 phase offsets technology to achieve delivery the energy input to the utility grid.
4
MaySun-1200W User Manual
5
MaySun-1200W User Manual
2. MaySun1200W Parameters
Input Data(DC) MaySun 1200W
Recommend PV modules 300W×4pcs
Maximum DC input voltage 50V
MPPT voltage range 25-40V/14-20V
Operation voltage range 10.5-50V
One way maximum input current 20A
Exterior
Ambient temperature range -40℃ to +60℃
Operation temperature range(inverter inside) -40℃ to +82℃
Dimensions (WxHxD) 370mm×305mm×38mm
Weight 2.85kg
Waterproof rating IP65
Cooling Natural convection - No fans
Feature
Power transmission mode Reverse transfer, load priority
Electromagnetic compatibility EN50081.part1 EN50082.part1
Grid disturbance EN61000-3-2 Safety EN62109
Grid detection DIN VDE 1026 UL1741
Package
Inner box Dimensions 430×375×115mm
Unit G.W. 4KG
Carton Dimensions 440x410x265mm
Carton G.W. 8.6KG
6
MaySun-1200W User Manual
3. Installation
3.1 Notes before installation
3.1.1 Check the product and the parts if complete, the list as below:
MaySun-1200W Microinverter 1
User Manual 1
Screws 1
Auxiliary support 1
AC cable 1
7
MaySun-1200W User Manual
3.1.4 Confirm the voltage and frequency of the MaySun-1200W which you ordered is match with
your local utility grid.
Except bracket, solar panel, inverter and other related parts, you also need the below
tools and parts:
Screw driver
Monkey wrench
Wire stripper
AC distribution box
breaker
3.2 Installation step:
3.2.1 Fix the Maysun1200W Micorinverter in the right position according to the bracket and
junction box.(eg. Install it in the middle of the 4 solar panels.)
8
MaySun-1200W User Manual
3.2.2 Use the AC cable to connect the neighboring Maysun1200W Microinverters, and the
end terminal of cable connect to the AC box.
Before connect the AC box, make sure do not connect to utility grid.
Select the right earth leakage protection switch and breaker according
to the system maximum current.
3.2.3 Covered the solar panel with opaque object, then connect the Maysun1200W
Microinverter with the 4pcs of solar panel.
9
MaySun-1200W User Manual
3.2.4 Check all the terminal in right and stable connected ,then connect to utility grid and
remove the opaque object on the solar panel.
3.2.5 Check the LED on the Maysun1200W, if the LED in green, congratulations, you
complete finish the installation.
1、 LED instructions: DC power supply the LED,if the DC voltage around 10.5V, the LED will light up.
2、 LED in green:
LED stable green :Microinverter work,MPPT locked.
LED flicker green:Microinverter work,MPPT is been tracking.
3、 LED in red:
LED stable red:protection statue, check ○ 1 DC voltage if low(below 10.5V)or high(above
50V)○Utility grid power off or the utility voltage is not match the Microinverter ○
2 3 Short circuit
of AC terminal.
Red Green Flashing:○ 1 Microinverter start to work;○ 2 input voltage or current not stable, pls
10