You are on page 1of 10

MaySun-1200W Microinverter

Dongguan Maywah Electronics Co. Ltd


Add.:3rd Floor, Shenzhou Science And Technology
Park,No.37 Xingwu Rd., Wusha Community,
Changan Town, Dongguan, Guangdong, China
Tel:86-769-89874285
Fax: 86-769-89874285
© All rights reserved
MaySun-1200W User Manual

Important Safety Information,Read this First!

This manual contains important instructions to follow during installation and maintenance of the
Microinverter. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the
Microinverter, the following safety symbols appear throughout this document to indicate dangerous
conditions and important safety instructions.

Warning Sign This indicates a situation where


failure to follow instructions may be a safety hazard or
cause equipment malfunction. Use extreme caution and
follow instructions carefully.

Heat Sign Burn hazard, if not follow instruction may be

burned. Use extreme caution and follow instructions


carefully.

Safety Instructions:

 Be aware that the body of the Microinverters is the heat sink and can reach
a temperature of 80 ℃ under extreme conditions. To reduce risk of burns,
do not touch.

Please install the inverter where children can not reach to reduce risk of

shock and burns. Minors and mental patients prohibition use of this
products.

 Perform all electrical installations in accordance with all local electrical codes.
 Be aware that only qualified personnel should install and/or replace Microinverters.
 Connect the Microinverter to the electrical utility grid only after receiving prior approval from the utility
company,and only qualified electrical engineer can perform the operation.
 Non-professionals do not disassemble or repair the inverter. If the inverter fails, please contact your
dealer or manufacturer.
 Before installing or using the Microinverter, please read all instructions and cautionary markings in the
technical description and on the Microinverter system and the PV-array.
 Please install the inverter in ventilated place and away from flammable materials.
 Do NOT disconnect the PV module from the Microinverter before removing AC power.
 The inverter transform solar photovoltaic (PV) DC power into AC power and fed into the power grid. Do
not use this product for other purposes, for any damage and loss resulting from non-intended use, the
manufacturer / supplier disclaims all responsibility.

2
MaySun-1200W User Manual

1. Product description:
1.1 Appearance and instructions

① ⑦ ②
⑤ ⑥

8
③ ④

① PV input(MC4)1
② PV input(MC4)2
③ PV input(MC4)3
④ PV input(MC4)4
⑤ AC input- connect to the previous
⑥ AC output-connect to the next
⑦ LED display
⑧ Item No.

1.2 Product dimension:

3
MaySun-1200W User Manual

1.3 Product features:


 MPPT(maximum power point tracking),effectively track and lock maximum power output
of solar panels
 When the inverter track the maximum power point of the solar panel, it will automatically
locked and with stable output
 4 independent MPPT(MPPT)
 standard MC4 input port,easy and safe installation
 Integration AC output port
 Pure sine wave output
 anti-islanding protection function:inverter will automatically stop output when the utility
grid off or fault.
 Over-temperature protection, short current protection and over-load protection
 IP65 waterproof function

1.4 System structure drawing

A
B c
D
E F
A:solar panel(PV)
B:MaySun-1200W Microinverter
C:AC cable
D: AC distribution box
E:home utility
F: low voltage utility grid

Description:Connect 4PCS of solar panel to 1pc of MaySun1200W Microinverter. The inverter use
MPPT function to absorb the maximum energy from solar panels, then use high efficiency inverter
conversion to transform the DC to AC, and then use the synchronous high-frequency modulation
and 0 phase offsets technology to achieve delivery the energy input to the utility grid.

4
MaySun-1200W User Manual

1.5 Application design sketch

5
MaySun-1200W User Manual

2. MaySun1200W Parameters
Input Data(DC) MaySun 1200W
Recommend PV modules 300W×4pcs
Maximum DC input voltage 50V
MPPT voltage range 25-40V/14-20V
Operation voltage range 10.5-50V
One way maximum input current 20A

Output Data(AC) @120VAC @230VAC


Peak power output 1200Watt 1200Watt
Rated output power 1150Watt 1150Watt
Rated output current 9.58A 5A
Rated voltage range 90-160VAC 180-260VAC
Rated frequency range 50Hz/60Hz Auto 50Hz/60Hz Auto
Power factor >98% >98%
Maximum units per branch 3pcs(single phase) 5pcs(single phase)
Permission Max-current per branch 30A 30A

Efficiency @120VAC @230VAC


MPPT efficiency 99.5% 99.5%
Maximum output efficiency 92% 92%
Night power consumption <50mW Max <70mW Max

Exterior
Ambient temperature range -40℃ to +60℃
Operation temperature range(inverter inside) -40℃ to +82℃
Dimensions (WxHxD) 370mm×305mm×38mm
Weight 2.85kg
Waterproof rating IP65
Cooling Natural convection - No fans

Feature
Power transmission mode Reverse transfer, load priority
Electromagnetic compatibility EN50081.part1 EN50082.part1
Grid disturbance EN61000-3-2 Safety EN62109
Grid detection DIN VDE 1026 UL1741

Package
Inner box Dimensions 430×375×115mm
Unit G.W. 4KG
Carton Dimensions 440x410x265mm
Carton G.W. 8.6KG

6
MaySun-1200W User Manual

3. Installation
3.1 Notes before installation
3.1.1 Check the product and the parts if complete, the list as below:

Product or parts name Quantity

MaySun-1200W Microinverter 1

User Manual 1

Screws 1

Auxiliary support 1

AC cable 1

3.1.2 Check the installation Ambient if as requested:


 Local ambient temperature is -20℃~60℃;
 No easy corrosive gas or liquid nearby;
 Not be installed in easily flooded or snow-covered areas;
 Not be installed in an enclosed or non-ventilated place;
 Prohibition install it near flammable materials;
 Not be installed in direct sunlight;
 Install the Microinverter in the place where children can not touch.

3.1.3 Solar panel if as requested:


 Recommend to use 60cells or 72cells solar panel,the Voc must be in the range of the
inverter’s operation voltage range. If you use 36cells solar panel, you can connect 2pcs
in series then connect to Micoinverter, and the total power can’t over 350W.
 There have 4 input ports of the MaySun-1200W,we recommend to use 4pcs of solar
panel to connect with the Microinverte.
 MaySun-1200W input port use standard MC4 connector, please check if there have
MC4 connector of solar panel.

7
MaySun-1200W User Manual

3.1.4 Confirm the voltage and frequency of the MaySun-1200W which you ordered is match with
your local utility grid.
 Except bracket, solar panel, inverter and other related parts, you also need the below
tools and parts:
 Screw driver
 Monkey wrench
 Wire stripper
 AC distribution box
 breaker
3.2 Installation step:

Prohibition to connect the Maysun1200W Microinverter to utility grid


3.2.1 if do not install the inverter following the below steps.
3.2.2
3.2.3

Please determine the installation site refer to 3.1.2

3.2.1 Fix the Maysun1200W Micorinverter in the right position according to the bracket and
junction box.(eg. Install it in the middle of the 4 solar panels.)

Make sure the inverter and bracket grounding, otherwise install a


dedicated line for the inverter of grounding.

8
MaySun-1200W User Manual

3.2.2 Use the AC cable to connect the neighboring Maysun1200W Microinverters, and the
end terminal of cable connect to the AC box.

Before connect the AC box, make sure do not connect to utility grid.

If the AC output voltage in the range of 200-250V, the maximum is 5pcs


Maysun1200W Microinverters for each branch; if the AC output voltage
in the range of 100-130V, the maximum is 3pcs Maysun1200w
Microinverters for each branch; the maximum current is 30A for cach
branch.

Select the right earth leakage protection switch and breaker according
to the system maximum current.

3.2.3 Covered the solar panel with opaque object, then connect the Maysun1200W
Microinverter with the 4pcs of solar panel.

Maysun1200W have 4 DC input ports, each input port can connect


maximum 350W(20A), over power or over current will damage the
Maysun1200W.

9
MaySun-1200W User Manual

3.2.4 Check all the terminal in right and stable connected ,then connect to utility grid and
remove the opaque object on the solar panel.
3.2.5 Check the LED on the Maysun1200W, if the LED in green, congratulations, you
complete finish the installation.

1、 LED instructions: DC power supply the LED,if the DC voltage around 10.5V, the LED will light up.
2、 LED in green:
 LED stable green :Microinverter work,MPPT locked.
 LED flicker green:Microinverter work,MPPT is been tracking.
3、 LED in red:
 LED stable red:protection statue, check ○ 1 DC voltage if low(below 10.5V)or high(above

50V)○Utility grid power off or the utility voltage is not match the Microinverter ○
2 3 Short circuit

of AC terminal.
 Red Green Flashing:○ 1 Microinverter start to work;○ 2 input voltage or current not stable, pls

check if there have enough current from the solar panel.

4. Steps for replace fault Microinverter:


1、 Use opaque object to cover the solar panels which connect to the fault Microinverter;
2、 Disconnect the fault Microinverter and utility grid;
3、 Disconnect the fault Microinverter and AC cable;
4、 Disconnect the fault Microinverter and solar panel;
5、 Remove the fault Microinverter from the bracket;
6、 Fix the new Microinverter to the bracket;
7、 Connect the new Microinverter to the AC cable;
8、 Connect the new Microinverter to the solar panel;
9、 Connect the new Microinverter to the utility grid;
10、Remove the opaque object on the solar panel.