POWERTRUSS BRACE - LATERAL BRACING

FRAME INSTALLATION

Powertruss Brace
62mm - Depth
M20 Anchor Positions

Min sl ab edge di stance to

60
Corner of Slab 31 centre of anchor
31

Min. Powertruss Studs/ Door/Window Openi ng


70mm Brace SHS Post
Available Widt hs:
200mm, 250mm, 300mm, 350mm, 400mm, 450mm,
500mm, 550mm, 600mm & 900mm

Minimum allowable distance = 70mm from corner of slab to start of Powertruss Frame
PRE ENGINEERED FIXED ANCHOR POSI TIONS - AS PER BASE

STANDARD M16 THREADED ROD CUT TO LENGTH, (OR SUITABLE LENGTH


BOLT) WITH NUT & WASHER BY CONTRACTOR.

TOP FIXING FOR STEEL FRA ME CONSTRUCTION


USE MIN. 10 X 12G SC REWS TO TOP PLATE IN A STAGGERED
LINTEL/BEAM ARRANGEMENT, AND EVENLY SPACED ALONG THE FULL WIDTH OF
THE POWERTRUSS FRAME.

MAXIMUM Ø8 HOLE IN EACH BAY FOR


STUD FIXING.
SLAB TO UNDERSID E OF TOP PLATE (MM)
TYPICAL POWERTRUSS BRACE HEIG HT

MAXIMUM Ø25 HOLE IN VERTICAL LEGS ONLY FOR


ELECTRICAL CONDUIT, LOCATED JUST ABOVE
HORIZONTAL MEMBER IN TOP HALF OF FRAME
ONLY.

TIMBER OR STEEL FRAME CONSTRUCTION

POWERTRUSS BRACE

PRE ENGINEERED FIXED ANCHOR POSI TIONS - 12mm THICK (MINIMUM)


STEEL BLOCK WASHERS WELDED TO INSIDE OF VERTICAL MEMBERS
(BENEATH BOTT OM HORIZONTAL MEMBER)

CUT OUT BOTTOM PLATE AND FIX DIRECT TO SLAB USING M20
GRADE 8.8 (HIGH TENSILE ANCHORS WITH RAMSET REO 502 PLUS -
REFER CHEMICAL ANCHOR FIXING INSTRUCTIONS.

PLEASE ADVISE FINISHED HEIGHT AND WIDTH FOR EACH BRACE REQUIRED

POWERTRUSS WALL BRACING SYSTEM


Queensland (Head Office) New South Wales Victoria
Unit 4-175 Railway Pde 18-20 Charles Street 16 Gaine Road
THORNESIDE, QLD. 4158 ST. MARYS , NSW 2760 DANDENONG SOUTH, VIC. 3175
Phone: (07) 3245 4930 Phone: (02) 8646 3366 Phone: (03) 9799 9122
Facsimile: (07) 3245 4838 Email: nsw@powertr uss.com.au Facsimile: (03) 9799 9800