You are on page 1of 16

ALANKAR

First LHS Cables


Manufacturer In Asia
ABOUT US
PROTECTING ESSENTIAL LIVES AND ASSETS FROM FIRE
Alankar Cable Industries has been established since 1971. As a small scale unit for the manufacturing of
LT Cables. Which was initiated by the Chief Executive Mr. H.L Kohli who is a management specialist.

We have successfully marched ahead in technical innovation in the field of manufacturing activities with
Diverse prints during this long journey of experience expertise and in house research and development
Activities we have developed specialized cables with focus on higher temperature readings sub-zero
Ambient temperature performance and LSZH, Fire Survival, LHS & Accessories in keeping view of
Emerging technologies and innovative demands of enlightened customers and overseas trends a new
Era has begun with our launching of Zero Halogen Low Smoke and nominal fumes (ZHLS/ LSF) cables
Replacing the conventional LT PVC Cable. We have acquired UL certification for most of our products and
we are the only enterprise in Asia to achieve this.

OUR COMPANY VISION


We strive to be the best in business by increasing customer satisfaction & providing innovative product
and services that are less harmful to environment and serves society helps in life saving.
We want to become true partner to every business for our clients.
We aspire become a competitive company in the field of sales and services.
We forbid the use of plastic to reduce carbon emissions by using non PVC, recyclable polymers,
halogen free plastic and other eco friendly materials.

OUR MISSION
Be the best contractor and consultant for our customers in each business industry.
Deliver operational excellence to our customers in each business industry.
Educate market with passion to help them grow in each business industry.
Research & Development Innovations

1996 : Started R & D work for indigenous development & commercialization of


halogen free wires & cables.
2005 : Successfully Indigenized Halogen free wires & cables for Indian market.
2008: Successfully developed Indigenized and started commercial production of
fire survival cables with halogen free construction.
2008: Exported 50 Kms of Fire survival cables for prestigious oil jetty project in
Mauritius.
2009 : Started R & D work on Nuclear Radiation Resistant wires & cables (Under
Development).
2010 : Successfully developed and supplied Indigenized Marine and Offshore
Halogen free cables as per IEC specifications.
2011 : Successfully developed and supplied indigenized LFH Marine and Offshore
Halogen free cables as per Def-Stan-61-12 specifications.
2012 : Successfully developed and supplied indigenized under sea cables for
Desalination Plant.
2013 : R & D Work going on for development of fire survival cable that can with-
stand all three fire testing as per category C, W & Z on same cable.
2014 : Successfully Introduced Digital LINEAR HEAT SENSING (LHS) CABLES.
2015 : Got European approvals for (LHS) Cables 2016 Successfully Certified UL
listed LHS Cables.
2017 : Successfully developed robotic cables.
2018 : Successfully Developed LHS cables for -30 Degree Centigrade.
2019 : Successfully introduced Alarm point distance locater for Digital LMS cable.
2020 : Three new LHS cable developed and got UL Listing.
2021 : Successfully developed Analogue LHS cable with control unit &
Accessories.

Under development optical fibre base LHS cable with panel.


Certificates
Certificates
Digital Linear Heat Sensing (LHS) Cable
Type of Digital Linear Heat Sensing Cable
Certified

ACI LHS 57 - 135 35 57 UL


ACI LHS 68 - 155 45 68 UL
ACI LHS 78 - 172 50 78 UL
ACI LHS 88 - 190 70 88 UL
ACI LHS 110 - 230 70 110 UL
ACI LHS 138 - 280 100 138 UL
ACI LHS 187 - 369 150 187 A/F

Type of Digital Linear Heat Sensing Cable (SS Braiding)


Certified

ACI LHS 68 - 155 45 68 –


ACI LHS 78 - 172 50 78 UL
ACI LHS 90 - 194 70 90 UL

Applications
Car Parking Moving Walkways Cable Tray Conveyor Belt
Escalators Cooling Towers Metro System Train Station
Solar Panels Platforms Industrial Power Plant
Transformers Vehicle System Bridge Floating Roof Storage Tanks
Electrical Apparatus Warehousing Mining Transformers
Manufacturing Rack storage Cold Stores Platforms
Baggage Handling Pipelines Valves and Motors Machinery
Escalators Engine Fuel Storage Communications
HGV Engine Bays Elevator shafts Compartments General Industries
Trains Carriage Couplings Aircraft hangars Off Shore Etc.
Digital LHS Cable Accessories
Distance Locater (ACDL)
A 24VDC external regulated power supply must be used to power
the ACDL. The ACDL can identify the Exact location of overheating
condition along the LHS Cable Installed. Distances are shown in
meters from the distance locating module. The ACDL Distance
Locating Module is for indoor use, and may be used with both
addressable and conventional "ALANKAR" Cable linear heat
detection systems.

Junction Box
The Junction Box is a basic method of jointing either provided with
military grade conductors Digital or Analogue LHS and is Supplied
with two glands. Made from heavy duty still sheet made on CNC JUNCTION BOX

machine. It can also be used as a connection junction box between PART NO. JB-02-ACI

long service life. An interposing cable and the LHDC.

End of Line (EOL)


The EOL is a basic method of terminating either digital or analogue
LHS cable. It is suitable for the majority of application and can be
easily fixed in place.

Cable Support Accessories


“Fireguard Analogue”
LHS Cable with Control Unit

Description
Fireguard Analogue sensor cable senses temperature Variations by
continuously monitoring the resistance of specially doped NTC polymeric
insulation. A change in temperature produces a relative change in resistance
Between the two loops within the sensor cable – as temperature increases,
resistance is lowered .Provided the sensor cable has not been directly subjected
to temperatures greater than 1200c for excessive periods, it will recover to an
alert condition after activating an alarm. Upon destruction, Fireguard analogue
cable fails permanently into the alarm state.

Benefits
• Recoverable after operation.
• Sensitive to small temperature variations.
• CE Approved and Rohs compliant.
• Open and short circuit detection reduces the risk of false alarms.
• Optional pre-alarm setting allows the user to manage risk more effectively.
• Cable based sensing allows detection at the point of risk.
• Low installation and maintenance costs reduce total cost of ownership.
Analogue Cable Accessories
Control unit specification
Dimensions (w x h x d) 155 x 210 x 92 mm
Enclosure material Polycarbonate with removable cover
Enclosure rating -
Enclosure finish Light grey
Supply voltage 20-28 VDC
Current consumption normal & Fault <70mA
Current Consumption, Prealarm OR Alarm <80mA
Current Consumption, Alarm &Prealarm <100mA
Current Consumption, Fault <70mA
Operating temperature 0ºC –50ºC (32°F –122°F)

Visual indicators Function Colour

Pre-Alarm & Alarm Red 1,Red2

Fault Amber
Power Green
Relay outputs ALARM, PREALARM (all Form C)
2A@30VDC load rating –resistive
0.25A@250VAC load rating –resistive
Fault output Opto-isolated Phototransistor Output
Max 50V @ 20mA
Alarm/Pre-Alarm Temperature Range 70ºC –/ + 5%
INTERFACE MODULE

Conventional Analogue
LHS Cable Interface Unit
This Conventional analouge LHS (Linear Heat Sensing) cable interface unit
is designed to beused for Fire detection with analouge type LHS cable.
This unit is compatible to use with all standard conventional panel.

End of Line (EOL)


The EOL is a basic method of terminating either digital or analogue
LHS cable. It is suitable for the majority of application and can be
easily fixed in place.

Cable Support Accessories


Fire Survival Cables
We offer ideal fire survival cables to be used as fire alarm cables, power
cables, control cables, telecom cables & data cables. These fire survival
cables are in zero halogen / halogen free compositions.
The blend of low pollution, toxicity, and corrosion levels and outstanding
product quality makes Alankar Fire Survival cables an option that should
be considered by anyone purchasing wires and cables products.

Standards & Application


Performance Data

BS 6387 CWZ: Category C- 9500C for 3 hours Category W: Fire at 6500C- 15 min Water Sprinkling – 15 min

Category Z: Fire at 9500 C Mechanical shocks For 15 Minutes


Halogen Free / LSZH Cables
Toll Free No : 18008912176