HERTZ INSPECTION & SERVICES PVT. LTD.
eer,
Doe F/1R/003 Ver¥or De 04/11/2019
INSPECTION REPORT
Client: - Mis. Think Gas Distrbution Pvt Ltd | Vendor: -M/s. Inel Gas Controls Pvt. Ltd.
LOI No: « TGDL/CKP/2018-20/G./MSAI024 | Location: -E-11, EPIP Zone, GIDC Estate, Manjusar,
Date: -27/02/2020. Vadodara-391775.
Project: Supply of District Regulsting Skid
Report No -TGPLINEL/PALLAV/11-20/001 | Date of Visit: - 04/11/2020
MATERIAL INSPECTED THIS VISIT
Sr. No. Offered Quantity Description
As 03 Skid (ORS TYPE--1000 | Inter Connecting Piping Spool for DRS TYPE-I-1000 SCMH) &
‘SCMH) & 10Nos Filters Filters (JIG:1421/SIG-6782 to 6784 & CF-1265 to 1274)
“Any Non
Results of Order :
tapocton Accopted: Compliance | SINCE | Complete: | Incomplete:
Ok ‘Ok No = Yes No
‘SUMMARY:
Inspection done at above location, where documents reviewed as per approved QAP and Hydro
test carried out for inter connecting piping spool for DRS TYPE-III-1000 SCMH) & Filters
(J1G:1421/S1G-6782 to 6784 & CF-1265 to 1274) as per approved GAP. In section found to be
‘accepted as per approved QAP.
Offered Qty.: Skid 03 & CF-10 Inspected Qty.: Skid 03&CF-10 | Rejected Qty.:00
Tnspecting Engineer Wir Limbachiya Patay.B
Page of 3HERTZ INSPECTION & SERVICES PVT. LTD.
eer
Doc # F/IR/001 Veron Be 04/11/2019,
INSPECTION REPORT
2.0 Persons Present:-
|. Mr, Jodhu Gohil, Assistant Manager QA/QC (M/s. Inel Gas Controls Pvt. Ltd.).
|. Mr, Pallay Limbachiya, Inspection Engineer (M/s. Hertz Inspection & Services Pvt. Ltd),
3.0 Documentation Used/Approval Status
Reference Document: -
NL. QAP. NO, IGCPLIJIG/1421/TGDLIQAPISKID/101, APPROVED.
IV. LOI.NO. TGDL/CAP/2019-20/6,/MSA/034 DT:27.02.2020, APPROVED.
V. GAD. NO. IGCPLJIGITGPL!1421/GAD/103 Rt APPROVED.
Vi P&ID. NO. IGCPLIJIG/1421/TGPLIP&ID/103 R3, APPROVED.
Vil. ASME SEC-Ix.
VIL ASME SEC-V.
1X ASME SEC-Vill Div,
Reviewed Document as mentioned below: =
X. Reviewed Pipe MTC and Lab Report as per QAP and found in order.
XI, Reviewed Pipe Fittings & Flanges material Test certificates reviewed as per QAP and
found in order.
XI. Reviewed WPS, POR & WPQ for welding & Welder Qualification as per QAP and found
in order.
Xill, Reviewed welding Inspection report reviewed as per QAP and found inorder.
XIV. Reviewed DPT of all Nor-Radiography weld joints (Fillet joints) Report and found ok.
XV. Radiographic testing for all Bult weld joints, Report reviewed as per QAP and,
found acceptable.
XVI Visually & Dimensional Checked Fit Up Orientations, Workmanship & Completeness of
Piping Joints/Spools & CF (Welding) and found as per DRG
XVII. Welded and Parent metal surtace area were visually checked and found no damaged,
cuts, spatters, Arc strikes & other surface defects and found Satisfactory.
XVIIl.__ All Fabricated spools & CF welding joint no. verified as per welding inspection report and
found inorder.
40 Inspection Carried Out (Includes Corrected Non-conformance):
|. Hydrostatic test Witness of inter Connecting Piping Spools (total = 03 nos Skids.) and
Cartridge Fitters (CF) = 10nos.for DRS-1000 SCMH @ Bar (g) for 150# and @ 74 Bar
(g) for 900% Held 240 minutes and Found No Leakage at all Joints (welded and
Assembled Flange to Flange and thread joints) & No Pressure drop during the Holding
time hence found Acceptable.
Page 2 of 3(Gy HERTZ INSPECTION & SERVICES PVT. LTD.
[veror Be oan oIS
INSPECTION REPORT
Testing Equipment’s Used/ Calibration status:
v.
vil
Equipments, Calibration Certificate No. Calibration
Se] Raernenes:|_ Moke Sr.No. (with NABL Traceability) due date
1. | Pressure [Baumer] 140004 ccs/442i20-24 14.06.2021
2 Gauges [General 17127036 ecsi4ati20-24 14.06.2021 |
Ml, Result / Conclusions (if any Non-conformance found}: NO.
IV. _ Inspection carried out as per above mentioned approved documents hence Hydro Test
for Inter Connecting Piping Spools for DRS TYPE-lI-1000 SCMH & Filters
(JIG1421/S1G-6782 to 6784 & CF-1265 to 1274) are found to be acceptable as per
reviewed documents and approved QAP.
Marking Details:
7.1 Mark of Inspection: - Hydrostatic tested/witnessed Piping Spools & CF were marked on one end flange
with single hard stamp as.»
Enclosures:
Material Test Certificate for Seamless Pipe, Flanges & Fitting.
NOT Reports.
Calibration Test Cerificate for Pressure Gauge.
Internal Inspection Report
Next Visit / Exit Call: To be advised
Images: Not Allowed by Vendor
Page 3 of 3