You are on page 1of 1

PRODUCT INFORMACTION INDEX DATE

Dep. 8
IT-G-A-60-002e October 2005

KNOCK MONITORING SYSTEM


DETCON-PLC INTERFACE. CONTROL ALGORITHM PARAMETERS

1. INTRODUCTION
DetCon knock monitoring system provides three digital signals and an analogic signal to the plant control system
(PLC or similar).

The value and the state of the different signals is function of the knock level registered by the sensors. In each
case, the plant control must operate in accordance with the product information IT-G-A-60-001e to optimize the
system operating.

2. PARAMETERS
Next table shows the recommended values for the different configurable parameters of the algorithm that must be
implemented in the plant controller (PLC), always taking as base the information in IT-G-A-60-001e.

This values are subject to updates in function of the experience obtained.

Parameters Unit Proposed value


t1 second 1
t2 second 10
t3 second 300
t4 hour 3
t5 hour 3
t6 second 5
DP% % 15
SP%/s %/s 0.15
X - 6
Y - 2