CTRC/TES/DRS/ ENV
Testing Services
Model Name:
Ratings of Model :
Date of Performance :
Standard/Clause:
Tested by Checked by
Issue No. 01 Dt.01.06.21 Rev. No. 00 Dt. …. Page 1 of 4
Classic Testing & Research Centre Format No. CTRC/TES/DRS/ ENV
Testing Services
DATA SHEET:
Engineer Nane/Signature
Date of Test
Standard
Sample ID
SUMMARY OF TEST
Reference Standard Test Method Standard Tests performed (name of test)
Tested by Checked by
Issue No. 01 Dt.01.06.21 Rev. No. 00 Dt. …. Page 2 of 4
Classic Testing & Research Centre Format No. CTRC/TES/DRS/ ENV
Testing Services
Sr. Test Name TEST METHOD TEST PARAMETERS OBSERVED RESULTS Verdict
no.
1. Protected 13.3 of IEC60529 Protected against solid foreign objects
against solid of 2,5 mm ∅ and greater :
foreign (First characteristic Numeral 3)
objects of The following specifications are
2,5 mm ∅ required;
and greater • A Rigid steel rod 2,5 mm diameter
: (IP 3X) with edges free from burrs
(Clause C. • Test force of 3 N (±10%) The
13.3 of protection is satisfactory if the full
IEC60529 ) diameter of the probe does not pass
through any opening
2. Protected 14.2.3 of IEC 60529 Protected against spraying water :
against (Second characteristic numeral 3) The
spraying EUT is to be sprayed ±60° from vertical
water: (IP on all sides of the enclosure with water
X3) (Clause from a spray nozzle with a delivery rate
14.2.3 of IEC of 10 l/min.
60529 ) The test duration per square meter
of enclosure surface area sprayed
shall be 1 minute.
The minimum duration of the test
shall be 5 minutes.
The distance from the nozzle to the
enclosure surface shall be 300
millimeters.
Statement of Result:
Tested by Checked by