You are on page 1of 1

One-Line Diagram - OLV1=>...

=>CENTRAL CULEBRA 1 (Load Flow Analysis)


CENTRAL DE GENERACIÓN CULEBRA 1 CENTRAL DE GENERACIÓN RENTADA

MG-01 MG-05
MCO-0825 MG-03
MCO-0835 920 kW MG-02 920 kW
1705 kW 1705 kW 920 kW 920 kW
842.1 kVA 526.3 kVA 894.7 kVA
1311 kVA 1318 kVA 894.7 kVA 1042 A
1521 A 1528 A 981.4 A 615.4 A
1042 A 95% PF
95% PF 95% PF 95% PF 95% PF
95% PF
CB1-CUL-GG1 CB1-CUL-GG6 CB1-CUL-GG7
CB1-CUL-GG0366 CB1-CUL-GG3 CB1-CUL-GG5 4000 A
4000 A 4000 A 4000 A 4000 A
4000 A

C-DPT-CUL-GG1 C-DPT-CUL-GG7
C-DPT-CUL-GG3 C-DPT-CUL-GG5 C-DPT-CUL-GG6
C-DPT-CUL-GG001 6-3/C 500 0.141 % Vd
6-3/C 500 0.207 % Vd 6-3/C 500 0.133 % Vd 6-3/C 500 0.084 % Vd
6-3/C 500 0.206 % Vd 6-3/C 500 0.141 % Vd 20 m
20 m 20 m 20 m
20 m 20 m

SUT-MG-01 SUT-MG-03 SUT-MG-05


SUT-0701 DPT-CUL-GG002 SUT-MG-02
2500 kVA 2500 kVA 2500 kVA
2500 kVA 2500 kVA 2500 kVA
0.48/13.8 kV 0.48/13.8 kV
0.48/13.8 kV 0.48/13.8 kV 0.48/13.8 kV
0.48/13.8 kV

C-CB2-CUL-GG1 C-CB2-CUL-GG5 C-CB2-CUL-GG6


C-CB2-CUL-GG001 C-CB2-CUL-GG002 C-CB2-CUL-GG4 1-3/C 2
1-3/C 2 1-3/C 2 1-3/C 2 20 m 0.006 % Vd
0.009 % Vd 1-3/C 2 0.009 % Vd 20 m 0.006 % Vd 1-3/C 2 20 m 0.004 % Vd
20 m 20 m 20 m 0.006 % Vd

RY-CUL-GG4 RY-CUL-GG5
TC2-CUL-GG0366 RY-CUL-GG-0366 RY-CUL-GG-0367 RY-CUL-GG004 RY-CUL-GG3 TC-CUL-GG5 o
o
TC1-CUL-GG0367 o
TC-CUL-GG004 o TC-CUL-GG4 o
R
100/5 TC-CUL-GG3 o
R
R R R R 400/5 400/5
TC1-CUL-GG0366 o
400/5 400/5 400/5
400/5
+K5(SWG-0082)4 +K5(SWG-0082)5
+K2(SWG-0082) +K3(SWG-0082) +K5(SWG-0082) +K5(SWG-0082)3 1250 A
1250 A 1250 A 1250 A
1293 kVA 1300 kVA 1250 A 834.5 kVA 1250 A 886.2 kVA 523.3 kVA 886.2 kVA
52.9 A 53.2 A 34.1 A 36.3 A 21.4 A 36.3 A
SWG-0082 13.8 kV 59 kA 95.75% PF 95.78% PF 95.51% PF 95.54% PF 95.32% PF 95.54% PF
3793 kVA 1922 kVA 14.1 kVA
+K4(SWG-0082)
155.2 A +K6(SWG-0082) 78.6 A +K7(SWG-0082) 0.577 A
1250 A +K7(SWG-0082)1 Open
96.57% PF 1250 A 93.45% PF 1250 A 89.95% PF
1250 A
o
RY-K04-SWG-0082 RY-K06-SWG-0082 TC-K07-SWG-0082 RY-K07-SWG-0082 o RY-K07-SWG-1
TC-K4Q0 TC-K06-SWG-0082
o

R TC-K08-SWG-0082
o

OCR OCR R
1200/5 400/5 400/5
400/5

XFM-CUL-001
YCA1-1-2/YCA1-1-1 SWG-0082/SWG-0136 300 kVA
LÍNEA ENTERRADA 13.8kV 13.8/0.48 kV
14.1 kVA
HACIA CULEBRA 21 (4.8 km) 16.6 A
90% PF

T. SER. AUXILIARES

page 1 12:58:30 jul. 01, 2021 Project File: BLOQUE61_SEIP_2020-19