System
SVC MANUAL(Exploded View)
MODEL : AH Series
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
Indoor
AHNW096A0 AHNW126A0 AHNW146A0 AHNW166A0
Indoor Units
(H09SNE) (H12SNE) (H14SNE) (H16SNE)
Combination Outdoor Units AHUW096A0 AHUW126A0 AHUW146A0 AHUW166A0
Nominal Power Input W 135 205 205 205
Nominal Running Current without Electric Heater A 0.59 0.89 0.89 0.89
Operation Range Cooling(Fan coil unit) °C 6 ~ 30 6 ~ 30 6 ~ 30 6 ~ 30
(Min.~Max.) Cooling(Under floor) °C 16 ~ 30 16 ~ 30 16 ~ 30 16 ~ 30
Leaving Water Heating(Fan coil unit or Radiator) °C 15~55℃ ( * * 20~55℃)
Temperature Heating(Under floor) °C 15~55℃ ( * * 20~55℃)
Pump Type - Canned type for hot water circulation
Steps of Speed EA 2 (In Max. / Med. / Min., Min. step is not used)
Power Input W 135 205 205 205
Water Flowrate Limit LPM At least 12 At least 12 At least 12 At least 12
Heat Exchanger Type - Brazed Plate HEX Brazed Plate HEX Brazed Plate HEX Brazed Plate HEX
Number of Plate EA 46 60 60 60
Quantity EA 1 1 1 1
Expansion Vessel Volume liter 8 8 8 8
Water Pressure(Max.) bar 3 3 3 3
Water Pressure(Pre) bar 1 1 1 1
Strainer Mesh Size mm 1x1 1x1 1x1 1x1
Material - Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Electric Heater Type - Sheath Sheath Sheath Sheath
Number of Heating Coil EA 2 2 2 2
Capacity Combination kW 2+2 3+3 3+3 3+3
Operation - Automatic Automatic Automatic Automatic
Heating Steps Step 2 2 2 2
Power Supply Ø / V / Hz 1 / 240 / 50 1 / 240 / 50 1 / 240 / 50 1 / 240 / 50
Rated Current A 16.7 25 25 25
Maximum Current(MCA) A 21 32 32 32
Water Circuit Safety Valve bar 3 3 3 3
Entering Side Diameter inch Male PT 1 Male PT 1 Male PT 1 Male PT 1
Leaving Side Diameter inch Male PT 1 Male PT 1 Male PT 1 Male PT 1
Manometer - O O O O
Drain Valve / Fill Valve - O O O O
Shut Off Valve - O O O O
Air Vent - O O O O
Refrigerant Circuit Gas Side Diameter mm(inch) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Liquid Side Diameter mm(inch) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
Dimensions Unit(W x H x D) mm 850 x 490 x 315 850 x 490 x 315 850 x 490 x 315 850 x 490 x 315
Packed Unit(W x H x D) mm 1082 x 563 x 375 1082 x 563 x 375 1082 x 563 x 375 1082 x 563 x 375
Weight Unit kg 52 54.5 54.5 54.5
(Without water) Packed Unit kg 57 61.5 61.5 61.5
*Sanitary Water Tank Type - Indirect heating(+ Electric heater)
(Field Supply) Heater Capacity kW Max. 3
Power Supply Ø / V / Hz 1 / 230 / 50
Power Supply Type - Separated power source
Thermal Protector Range °C Max. 90
Relay Contactor - Needed
ELB A 40
Sensor Adaptor Diameter mm(inch) 12.7 (1/2)
Accessory Kit - LG Supply
Note : 1. The specification may be subject to change without prior notice for purpose of improvement.
2. * : This information is given as a guideline about the connection of sanitary water tank
3. ** : This specification is data when electric heater is not used.
Note :
1. Capacities and power inputs are based on the following conditions:
* : Cooling conditions - Indoor Water Temperature 23°C/18°C; Outdoor Air Temperature 35°CDB/24°CWB
Heating conditions - Indoor Water Temperature 30°C/35°C; Outdoor Air Temperature 7°CDB/6°CWB
Standard piping length 7.5m
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Note :
1. Capacities and power inputs are based on the following conditions:
* : Cooling conditions - Indoor Water Temperature 23°C/18°C; Outdoor Air Temperature 35°CDB/24°CWB
Heating conditions - Indoor Water Temperature 30°C/35°C; Outdoor Air Temperature 7°CDB/6°CWB
Standard piping length 7.5m
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Notes
O : Applied, X : Not applied, – : No relation
* TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)'
* Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
Notes
O : Applied, X : Not applied, – : No relation
* TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)'
* Accessory: Installed at field, ordered and purchased separately by the corresponding model mane, supplied with separate
package.
Notes
O : Applied, X : Not applied, – : No relation
* TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)'
* Accessory: Installed at field, ordered and purchased separately by the corresponding model mane, supplied with separate
package.
Notes
O : Applied, X : Not applied, – : No relation
* TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)'
* Accessory: Installed at field, ordered and purchased separately by the corresponding model mane, supplied with separate
package.
Notes
O : Applied, X : Not applied, – : No relation
* Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
Med.
1.5
Max.
1.0
12
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100 110
Water Flowrate(l/min)
Model : AHNW126A0 (H12SNE), AHNW146A0 (H14SNE), AHNW166A0 (H16SNE)
8.0
7.5
7.0
6.5
6.0
5.5
Hydraulic Head Loss(mH2O)
5.0
4.5
Max.
4.0
3.5
Med.
3.0
2.5
2.0
1.5
1.0 12
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100 110
Water Flowrate(l/min)
Warning : Selecting a water flowrate outside the curves can cause damage to or malfunction of the unit.
: Operation cutoff range
5.0
4.5
Max.
4.0
3.5
Med.
3.0
2.5
2.0
1.5
15
1.0
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100 110
Water Flowrate(l/min)
Warning : Selecting a water flowrate outside the curves can cause damage to or malfunction of the unit.
: Operation cutoff range
Componets
Underfloor
Heating
Radiator
Sanitary water tan Solar thermal syst
k is installed em is connected
(Sanitary water tan (Solar thermal kit i
Basic installation k kit is necessary) s necessary)
(
(IDU + ODU))
WATER TANK
n IMPORTANT REMARKS
Store or Generate Hot
3P 2P FACTORY WIRING
3P 2P
R/C FIELD WIRING
2P
ACCESSORY (supplied by LG Electronics)
3rd PARTY ACCESSORY
3P (supplied by 3rd party company)
WATER E/HT ELB E/HT
MAIN POWER DISTRIBUTION
PUMP
T/B T/B T/B (A) T/S T/B ELB ELECTRIC LEAKAGE BREAKER
- 27 -
T/B TERMINAL BLOCK
M/C M/C
THERMAL SWITCH
CN_3WAY(B) CN_3WAY(A) CN_W/PUMP(B) CN_W/PUMP(A) CN_E/HEAT(B) CN_E/HEAT(A) CN_B/HEAT(A) CN_TH4
E/HT ELECTRIC HEATER
CENTRAL T/S
CONTROLLER WARNIG (READ DIRECTION
CAREFULLY TO PREVENT POTENTIAL
2P ACCIDENTS)
(including 3P
PI485 Gateway)
INDOOR UNIT
THERMOSTAT AND THERMO SWITCH INFORMATION n ACCESSORY INSTALLATION
Model : AHNW096A0, AHNW126A0, AHNW146A0, AHNW166A0, AHNW09606A0
3P or 4P 3P or 4P 3P • NEVER USE THERMOSTAT1 AND THERMOSTAT2 AT THE SAME TIME. IF USED, • To install accessory correctly, please refer to
FIRE ACCIDENT CAN BE OCCURRED BY ELECTRIC SHORT INSIDE PCB. installation manual presented by LG
Electronics
• HEATING ONLY THERMOSTAT : USE 3 PIN CONNECTION
THERMO- THERMO- THERMAL HEATING AND COOLING THERMOSTAT : USE 4 PIN CONNECTION
STAT1 STAT2 SWITCH CONNECTION INFORMATION : SEE PRODUCT INSTALLATION MANUAL(BY LG
ELECTRONICS) AND THERMOSTAT INSTALLATION MANUAL(BY MANUFACTURER).
230V AC 24V AC 230V AC • THERMAL SWITCH SHOULD BE NORMAL OPEN. IT SHOULD BE CLOSED AT
USER’S DESIGNED OPERATION TEMPERATURE. IF NOT, HEATING BY SOLAR
THERMAL SYSTEM CAN BE DEGRADED.
MCCB
M/C
380V
220V
50Hz
50Hz
3~
3~
or
MCCB
M/C
3
M/C
230V
50Hz
M/C
1~
M/C
50Hz
230V
1~
MCCB
M/C
380V
220V
50Hz
50Hz
3~
3~
or
MCCB
M/C
3
M/C
230V
50Hz
M/C
1~
MCCB
M/C
220V
50Hz
3~
MCCB
M/C
3
220V
50Hz
1~
M/C
380V
50Hz
3~
M/C
MCCB
M/C
M/C
220V
50Hz
1~
MCCB
3
M/C
M/C
380V
50Hz
3~
Model : AHNW096A0
AHNW126A0
AHNW146A0
AHNW166A0
733010
AHNW09606A0
552000
135511
268711E 268711B
148391
135500
269300
340090
263230G
752140 349001
263230B
552207
263230C 165020
566001
266007
152141
W6640C
235042
W6640B
261704
W52240
267110 158580
130411
265020
148382
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Model : AHNW09A06A0
AHNW09806A0
733010
552000
249951
268711E 268711B
148391
135500
340090
263230G
752140 349001
263230B
552207
263230C 269300A 165020
269300B
261704
152141
W6640C
566001A 235042
266007
566001B W52240
W6640B
267110 158580
130411
265020
148382
Model : AHNW16A06A1,AHNW16806A1,AHNW09A06A1,AHNW09806A1
249951
733010
137211
268711E 268711B
552000
263230G
263230B 752140
135500 340090
263230C 148391
349001
261704
566001A 165020
269300A
269300B
W6640C
552207
235042
152141
W6640B
130411 158580
267110
265020
148382
135510
733010
137211
268711E 268711B
552000
263230G
263230B 752140
340090
263230C 148391
135500
269300
165020
349001
552207
235042
566001
266007
W52240
W6640C
W6640B
130411 158580 152141
261704
267110
148382
137213A
554031
435511
549610 268711F
W4810
- 37 -
DISCHARGE
437211
349480 566000A
W6200
435301 561410
559010 35211A
566000B 552116
447910
661400
554160
552202
550140
437210
552203A
W6631
552203B
Comp. wire
430411
661400
552116
552203A
552203B
W49810
435511
137213A
649950
552115
552113
W6631
552202
553000A
PIPE-OUT/AIR
567480D
435300
W6200
35211A
566000
548490
268711F
554160
DISCHARGE
567480E
SUCTION /
430411
352150
549610
553000B
137213B
554031
546810
W4810
447910
559010
435512
437210
349480
435301
437211
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
237205
135500
437212
W6631
548490
435300
561410
550140
554160
552117
137213A
552560
552202
552116
566000
661400
552113
152503
552203A
55211E
552112
430410
263230A
263230C
263230B
554031
148000
552203B
435513
(M-PIPE)
CN-TH4
(PIPE2/DIS1)
(AIR/PIPE1)
W6200
CN-TH1
CN-TH2
W6640
447910
649950
268711
549610
137213B
346810
237202
437211
559010
349480
435512
435301
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Comp. wire
W52102
W6631
566000B
548490
435300
554160
566000A
552117
661400
561410
237204
552116
55211G
552111
649950
552115
430411
552202
W49810
268711
W6640B
554031
552203B
552203A
PIPE-OUT AIR
567480D
435513
W6640A
SUCTION-DISCHARGE
554031
567480E
W6200
268711F
447910
546810
546810
237202
137213
549610
559010
437211
349480
559010
435512
349480
435301
435301
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
237205
135500
437212
548490
W52102
566000B
435300
552116
554160
W6631
552117
552200
661400
566000A
237204
561410
W52240
55211G
552111
649950
552115
430410
552202
152503
268711C
W6640B
554031A
552203B
PIPE-OUT AIR
552203A
263230B
435513
148000
W6640A
SUCTION-DISCHARGE
554031B
263230C
W6200
268711B
263230A
MIDDLE
447910
546810
546810
237202
137213
549610
559010
437211
349480
559010
435512
349480
435301
435301
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)