You are on page 1of 1

Go back to Index Page

128 PID105
Description and measuring

SE2507 Charge-air (Boost) temperature sensor


Function Measures charged-air (boost) temperature (combined sensor).
Wiring diagram
VCADS Pro See test 28407-7 Sensor values, monitoring

EA11, frame ground


EA47, charge-air temperature signal
Control unit/ Frame ground cable
cable harness: 4 ≈0Ω
- Frame ground

1) 2) 3) 4)
Signal line 3
- Frame ground ≈ 5.7 KΩ

1) 2) 3)
Specific part of 3 - 4 See table below
system:

1) 2) 3) 4)

Sensor specification

Air temperature, ºC (ºF) Resistance Air temperature, ºC (ºF) Resistance


–40 (–40) 168 ± 13 kΩ +60 (140) 1240 ± 42 Ω
–30 (–22) 88 ± 6 kΩ +70 (158) 873 ± 33 Ω
–20 (–4) 48 ± 3 kΩ +80 (176) 627 ± 26 Ω
–10 (–14) 27 ± 2 kΩ +90 (194) 458 ± 20 Ω
0 (32) 16 ± 1 kΩ +100 (212) 339 ± 15 Ω
+10 (50) 9.9 ± 0.5 kΩ +110 (230) 255 ± 12 Ω
+20 (68) 6.2 ± 0.3 kΩ +120 (248) 195 ± 10 Ω
+30 (86) 4.0 ± 0.2 Ω +130 (266) 150 ± 8 Ω
+40 (104) 2648 ± 97 Ω +140 (284) 117 ± 7 Ω
+50 (122 1793 ± 58 Ω +150 (302) 93 ± 6 Ω