G1213-Z-DS-001 0
Document number G1213-Z-DS-001
Revision 0
Page 2 of 3
REVISION HISTORY
CHANGE DESCRIPTION
DESIGN DATA
1. Model EBT-100-5
2. Service Back-up Tong
3. Area classification ZONE II
4. Design standards FEM “Rules for design of Hoisting Applications”
5. Rules and regulations DNV
6. Environmental conditions: According to project specification
7. Environment Highly saline and corrosive atmosphere
8. Design temperature -20 to +45 C
9. Operating temperature -10 to +45 C
10. Safety Devices Locking claw, emergency stop
11. SWL Not designed for lifting
12. Weight, operating EBT 3900 kg incl control stand
13. Equipment shipment size ( L x W x H) 5,7x2,7x1,65 m
14. PERFORMANCE DATA
15. Vertical travel 1550 mm
16. Pipe range gripper head 3 ½” – 6 5/8”
17. Torque capacity 135 500 Nm
18. CONSTRUCTION
19. Code DNV
20. Certifying authority DNV
21. Equipment Category II
22. UTILITY CONSUMPTIONS
23. Max. Hydr. flow rate 220 l/min
24. Min. operating pressure 200 bar
25. Max. operating pressure 210 bar
26. Power consumption 0.2 kW
27. Voltage 24 V DC
28. HYDRAULIC OIL PIPING
29. Pipes / Fittings / Hoses Acc. to G1200-L-SA-001
30. SURFACE PROTECTION
31. Paint Specification and System No. Acc. to NOV doc. HLA-4A
32. Top Coat Colour Yellow (RAL 1006)
33. LUBRICATION/HYDRAULIC FLUID
34. Grease type Acc. to NOV doc. HLA-04A (eg. Multifak EP2)
35. Hydr. Oil type Acc. to NOV doc. HLA-04A (eg. Texaco Rando HD-Z
45)
36. Cleanliness requirement ISO 4406:99, Class 19/17/14 ~ Nas 8
37. ELECTRO
38. Cables IEC 331, IEC 92-353, IEC 332-3/A (flame retardant) and
IEC 754-1 (halogen free) and mud resistance. Cables
installed in service loops are delivered according to
IEEE 45, IEC92-3 and IEC332-3/A
39. Cable tray on equipment Stainless steel
40. Junction boxes on equipment Stainless steel, min. IP 56
41. Control cabinet in control rooms / LER / Safe Steel, min IP 22
area
42. DRAWING
43. General Arrangement G1213-D1156-G0001