Professional Documents
Culture Documents
European Standards
European Standards
In early 2000, the European Union created and adopted a new classification system for adhesives and grouts.
According to European Standards, classes EN 12004 and 12002 were created for adhesives and EN 13888 for joint
fillers, facilitating the easy identification and classification of products depending on their scope of application and
their technical specifications.
The classification of products is now based on performance and application characteristics and is referred to as
“symbols of compliance” on the packaging and the brochures of the classified products.
All of the above apply to more categories of products such as:
• rendering and plastering mortars (ΕΝ 998-1) • products and systems for the protection
• masonry mortars (ΕΝ 998-2) and repair of concrete structures (ΕΝ 1504)
• screed materials and floor screeds (ΕΝ 1381-3) • poducts for drywall joints (ΕΝ 13963)
• admixtures for concrete, mortar, grout (ΕΝ 934-2)
The CE marking is a certified guarantee for all types of products, with regards to the minimum characteristics re-
quired by the applicable standards. These characteristics remain unaltered for all relevant quantities.
The verification and compliance procedures for each product are defined in detail in the European technical specifi-
cations. All products are tested and comply with the appropriate European standards and regulations.
Those products that do not bear the CE marking, are not required to comply with the European standards.
Ιτ must be mentioned that for all DUROSTICK products not bearing the CE marking, the company certifications (ISO
9001 since 2000), the well organized and exceptionally equipped Chemical Laboratory as well as the Properties
Testing Laboratory, both located in the premises of DUROSTICK, as well as the highly skilled scientific staff and the
high tech, modern facilities together with and brand new mechanical equipment, are the strongest guarantee for
the quality and reliability of its products.
Ask for the DECLARATION OF PERFORMANCE for all products bearing CE mark.
Durostick has studied, designed and certified per the European standard ETAG 004, the Integrated System for Exter-
nal Insulation of buildings (External Thermal Insulation Composite System (ETICS)) with the name ‘THERMOSEAL’;
certification number EOTA: ETA-13/0006 and EOTA: ETA-13/0007. The system is registered ‘Class 1’ in measure-
ments made in the laboratories of the Notified body BVFS in Austria and was certified by the Notified Organization
OIB.
• Open time
• Slip
• Tensile adhesion • Compressive strength
EN 12004 • Compressive strength EN 998-1 after ageing of 28 days EN 998-2
strength after:
after 28 days of curing • Capllary water absorption
- 28 days in normal environment
• Capillary water absorption • Adhesion strength
conditions
• Adhesion strength • Fire reaction
- Heat ageing at +70°C
• Thermal conductivity • Thermal conductivity
- Immersion in water
• Fire reaction • Chloride ion content
- 25 freeze-thaw cycles
• Transverse deformation after 3
point bending load
8
Admixtures for concrete, mortar
Screed materials and floor screeds Products and systems for the
and grout are tested under the
are tested under the European protection of concrete surfaces are
European Standard 934-2 in the
Standard EN 13813 in the following: tested under the European Standard
following:
QUALITY QUALITY EN 1504-2 in the following:
CONTROLED CONTROLED
• Compressive strength • Uniformity QUALITY
CONTROLED
after ageing of 28 days • Color • Permeability SD to CO2
• Flexural strength • Bulk density • Capllary water
after ageing of 28 days • Dry residue absorption and
• Fire reaction EN 13813 • pH EN 934-2
vapour permeability
• Adhesion to concrete • Total chloride • Adhesion strength EN 1504-2
• Abrasion resistance • Water soluble chloride • Fire reaction
• Alkaline content after the application
• Water reduction
• Air content in cement
• Compression strength
• Hardening time
9
European standards
REQUIREMENTS OF EN 12004 STANDARD FOR TILE ADHESIVES
C1: C2:
Normal Improved
Adhesive type
cementitious cementitious
adhesive adhesive
Technical specifications Test method Minimum requirement
Tensile • 28 days in normal conditions* ≥ 0.50 Ν/mm² ≥ 1.00 Ν/mm²
adhesion • thermal ageing at +70° C for 14 days ≥ 0.50 Ν/mm² ≥ 1.00 Ν/mm²
ΕΝ 1348
strength • water immersion for 21 days ≥ 0.50 Ν/mm² ≥ 1.00 Ν/mm²
after: • 25 freeze-thaw cycles ≥ 0.50 Ν/mm² ≥ 1.00 Ν/mm²
Open time for tile installation ΕΝ 1346 ≥ 20 min ≥ 20 min
* Measurement conditions: Environment temperature 23±2°C, Relative humidity : 50±5%, Air speed : ≤ 0.2 m/s
Classifications A1/Α1fl: Non flammable
10
REQUIREMENTS OF EN 13813 STANDARD FOR CEMENT SCREEDS
Mortar type Technical specifications Test method Minimum requirement
C20 ≥ 20 Ν/mm²
Compressive strength after 28 days of curing
C30 EN 13892-2 ≥ 30 Ν/mm²
F4 ≥ 4 Ν/mm²
Flexural strength after 28 days of curing
F5 EN 13892-2 ≥ 5 Ν/mm²
Classification Α1fl: Non flammable
ΠΡΟΔΙΑΓΡΑΦΕΣ
CSII 1.5 - 5.0 Ν/mm²
CSIII Compressive strength after 28 days of curing* EN 1015-11 3.5 - 7.5 Ν/mm²
CSIV ≥ 6.0 Ν/mm²
SPECIFICATIONS
W0 Not specified
W1 Capillary water absorption (c) ΕΝ 1015-18 c ≤ 0.40 kg/m² . min0.5
W2 c ≤ 0.20 kg/m² . min0.5
T1 λ ≤ 0.10 W/mK
Coefficient of thermal conductivity (λ) ΕΝ 1745
T2 λ ≤ 0.20 W/mK
ΝΕΕΣ ΕΥΡΩΠΑΪΚΕΣ
11
European standards
REQUIREMENTS OF EN 204 STANDARD FOR
THERMOPLASTIC WOOD ADHESIVES FOR NON STRUCTURAL APPLICATIONS
Minimum
Adhesive type Technical specifications Test method Application areas
requirement
Suitableforinteriorconstructs,in
D1 7 days in normal conditions* ≥ 10 Ν/mm² whichthemoisturecontentofthe
wood does not exceed 15%. .
Suitableforinteriorconstructswith
7 days in normal conditions* ≥ 10 Ν/mm² occasionalshort-termexposureto
runningorcondensedwaterand/
D2
or to occasional high humidity
7 days in normal conditions* providedthatthemoisturecontent
≥ 8 Ν/mm² of wood does not exceed 18%.
3 hours in water at (20±5)°C
7 days in normal conditions* ≥ 10 Ν/mm² Suitableforinteriorconstructs
with frequent short-term
7 days in normal conditions* exposure to running or
EN 205 ≥ 2 Ν/mm²
4 days in water at (20±5)°C condensedwaterand/orheavy
D3
exposure to high humidity.
7 days in normal conditions* Suitableforexteriorconstructs
4 days in water at (20±5)°C ≥ 8 Ν/mm² notdirectlyexposedtoweather
7 days in normal conditions* conditions.