You are on page 1of 87

What is the AnyRidge way?

For clinicians… For patients…


less invasive, fast,
Realising the strong new
simple, predictable,
ONE-DAY Implant esthetic &
TM

& esthetically functional teeth via


superior implant painless & rapid
treatment treatment

AnyRidge does it right!


AnyRidge goes FAR BEYOND standard expectations of dental implants…

The key benefits of AnyRidge implants become evident


when considering immediate loading…

With the new loading protocol developed based on


clinical results with AnyRidge, your patients have
new smiles faster than ever….

• Guaranteed excellent stability, even with compromised bone density


• Less reduction & more preservation of cortical bone
• Wider implant possibilities than crestal width
• Clinically proven safety
• Faster & stronger osseointegration
• Esthetic design & varied abutment selection
• Super implant-prosthetic connection
• Innovative R2GATE software for completing implant
& prosthesis in ONE DAY

AnyRidge – a new design standard on the global stage


Have you made the
Launched in 2009 as a biologically-inspired implant concept,
PARADIGM SHIFT yet?
AnyRidge consistently surpasses clinical benchmarks Do it the AnyRidge way!
Key
Advantages

 xcellent initial stability even


E
at the compromised bone
density
No screw loosening
guaranteed!

Unique and valuable


ISQ pattern; essential for
predictable immediate or
early loading.

054 Characteristics & Advantages


054 Ⅰ. Design Concept
056 Ⅱ. Surgery
057 Ⅲ. Prosthetics
060 Ⅳ. Maintenance

061 Fixture Product & Packaging


061 Ⅰ. Dimension
062 Ⅱ. Fixture Size
066 Ⅲ. Packaging

067 Cover Screw & Healing Abutment

068 Abutment & Prosthetic options


068 Ⅰ. Fixture level Prosthesis
076 1. Extra EZ Post
084 Ⅱ. Abutment level Prosthesis
084 1. Solid Abutment & Components
088 2. Octa Abutment & Components
093 3-1. Multi-unit Abutment & Components
109 3-2. Multi-unit Abutment & Components
113 4. Flat Abutment & Components
116 Ⅲ. Overdenture Prosthesis
116 1. MegaGen Overdenture System
117 2. Meg-Loc Abutment & Component
120 3. Meg-Ball Abutment & Component
123 4. Meg-Magnet Abutment & Component
126 5. Meg-Rhein Abutment & Components

132 Clinical Cases Product coordinator: Hyun wook An, rnd_dir@imegagen.com


Characteristics & Advantages » Ⅰ. Design Concept

Characteristics & Advantages


I. Design Concept

Small but Strong Abutment Screw


Diameter 1.8mm

Thicker abutment wall


More favorable for path adjustment
Various post height
4.0, 5.5, 7.0, 9.0mm
Optimum post taper
✔ Different taper according to post diameter
(8°, 10°, 12°, 14°)
Flexibility of 1mm ✔ Wider diameter has more taper!
1mm trimmable margin gives restorative
flexibility without changing B-L dimension Various cuff height
2.0, 3.0, 4.0, 5.0mm

Biologic S-line
Single connection
Biologic S-line provides Abutment can be used on any size of fixture
seamless natural-looking
emergence profile
Wider fixture in a narrow crest
Maximizes long-term survival of a fixture
Maximum preservation
of cortical bone
Important for esthetics and long-term prognosis

No cutting edge, but strong


Knife-Threads self-threading
Offer progressive bone condensing, ridge ✔ Sharp cutting flutes slice and widen
expansion, maximized compressive force bone gradually.
resistance, and minimized shear ✔ No wobbling on cortical slope in anterior
immediate placement case.
force production.

Taper design
Easy to place always guarantees Narrow diameter
excellent initial stability Wider fixture into a small osteotomy socket
(less invasive surgery) is important to pre-
serve marginal hard and soft tissues.

054­
Characteristics & Advantages » Ⅰ. Design Concept

AnyRidge Fixture Line up


Same core diameter, but different thread depth

Fixture Diameter
Core
Diameter
3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0

2.8

Thread depth 0.3

3.3

Thread depth 0.35 0.6 0.85 1.1 NEW

3.8

Thread depth 0.35 0.6 0.85

4.0

Thread depth 0.45 0.7 0.95 NEW

4.3

Thread depth 0.35 0.6 0.85

4.8

Thread depth 0.35 0.6 0.85 1.1 1.35 1.6

AnyRidge – 055
®
Characteristics & Advantages » Ⅱ. Surgery

II. Surgery
Excellent initial stability, even at compromised bone density.
AnyRidge Fixture cuts bone smoothly and condenses it simultaneously.
®

1. Fixture placement • Soft bone


The super self-tapping threads have a single core diameter that facilitates minimal site
preparation by utilizing a smaller osteotomy to place a wider fixture with special threads.

• Hard bone
AnyRidge Fixture with its super self-tapping thread design is easier than other traditional implants at
®

hard bone.
*Caution! : The osteotomy socket (drilling) size should almost reach the size of fixture to avoid
getting stuck in the bone during placement.

<1mm 1mm >1mm 1mm

1 2

Easy way to avoid stuck in the bone during AnyRidge implant placement
1. Due to extremely strong initial stability of AnyRidge fixture, it can be stuck in the middle during
placement especially in mandibular hard bone. Please consider ‘One millimeter Rule’ to avoid this in the
best and easiest way. Clinician can customize the drilling sequence once he fully understand the concept
and characteristics of AnyRidge system to get preferred initial stability. ‘One millimeter Rule’ is simple; if
an implant engine (40Ncm) stops leaving one millimeter above the crest, use ratchet wrench to screw it
down to preferred position. We recommended to place implant platform 0.5~1.0mm under the crest.

2. If a fixture stucks in the middle leaving more than 1mm above the crest in hard mandibular bone, it is
recommended to remove it using a wrench rather than trying to screw it down with excessive torque.
Please use a cortical bone drill that is included in a surgical kit, the depth of cortical bone drilling can be
adjusted according to the bone condition. Then, place the same fixture into the osteotomy socket.

2. Customized drilling • AnyRidge® system has no fixed drilling protocol, just make your own protocol based on
patient’s bone quality to attain preferred initial stability or simply drill an osteotomy
Sequence socket to given conditions and then decide the diameter of a fixture.

Example 1) Ø5.0mm fixture


can be placed 2.9mm
osteotomy socket in D4 ➲ ➲
bone. Excellent initial stabil-
ity can be attained
Lance Stopper AnyRidge®

Drill Drill 2.8 Fixture 5.0

Example 2) In hard one, it


is highly recommended to
make a socket almost same
➲ ➲ ➲ ➲
diameter size as a fixture

Lance Stopper Stopper Marking AnyRidge®

Drill Drill 2.8 Drill 3.3 Drill 3.8 Fixture 4.0

• Improved drill design has simplified drilling sequence, you can even harvest autogenous
bone using these specially designed drills.
(Recommended speed : 50 RPM, 50 Ncm with saline solution irrigation)

• The best way to get ideal initial stability with AnyRidge system is placing a fixture using
a surgical engine, leaving one or two treads above the crest; then use ratchet wrench to
place the platform at the desired position.

056­
Characteristics & Advantages » Ⅲ. Prosthetics

Ⅲ. Prosthetics
Better esthetic outcomes from wide variety of prosthetic options!
Stop worrying about screw loosening!

1. No screw loosening, • Magic Five (5° Internal connection)


less biologic width! Now you can be free from screw loosening with our unique connection (5 degree morse
taper) which gives perfect hermetic sealing. Biologic width is minimized due to
no micro gap, and crestal bone health is well maintained.

AnyRidge
Separation force
between fixture
and abutment after
49.49 cold welding.

A Company A
1.5° Connection

25.36 B AnyRidge
5° Connection

11.46 Company B
8° Connection

(n=5)

Performed Retention Test to evaluate the fixture-abutment retention force using Universal Testing Machine
-R&D center in MegaGen Implant Co.,Ltd.(2009)-

2. Biologic S-line Helps to achieve beautiful, natural-looking esthetics.

3. Optimum hex height Feel AnyRidge connection. It starts with impression taking and lasts until final restoration.

4. All indications, various Every case, every shape, every size. Everything was considered to satisfy every need.

abutment options
Various
Post Heights

Complete
Cuff Height Hermetic Seal

S-line

[SEM Image] Magic Five


Connection : 5° Morse Taper

AnyRidge – 057
®
Characteristics & Advantages » Ⅲ. Prosthetics

▸▸ Two different connections between a fixture & a component

1. All transitional and


temporary components
have ‘Ledges’ on the
bottom

• Cover Screws, Healing Abutments, Impression Coping (transfer and pick-up type), Temporary
Cylinders have ledges on the bottom which prevent from cold welding with a fixture.
• Hand Drivers(1.2 Hex) or Impression Drivers can be used easily to screw these components
in and out.

2. All permanent abutments


will make strong
connections with fixtures,
even with finger force!

• 25~35Ncm is recommended to connect a permanent abutment into a fixture.


• A fixed abutment cannot be removed with finger force even after complete removal of Abutment
Screw because of perfect cold welding. To remove a permanent abutment, Abutment Removal
Driver should be used.

058­
Characteristics & Advantages » Ⅲ. Prosthetics

▸▸ How to remove Permanent Abutment from Fixture?


Due to extremely strong connection force, you don’t have to worry about screw
loosening. Please use our special ‘removal driver’ when you want to remove
an abutment from a fixture.

Hand Driver (1.2 Hex)


(Refer to Page.349)

1 2 3

Abutment
Removal Driver
(Refer to Page.350)

4 5 6

1. Use a Hand Driver(1.2 Hex) to unscrew Abutment Screw.


2. Continue to turn counter-clockwisely until you feel a click of disengagement.
3. Push down Hand Driver once again to catch and fix Abutment Screw.
4. Lift up Hand Driver lightly and continue to turn counter-clockwisely until Abutment Screw
engages with the inner screw of Abutment.
5. Remove Abutment Screw completely from the abutment
6. Insert an ‘Abutment Removal Driver’ and continue to turn clockwise until the abutment
c
 omes out of fixture. You can feel some resistance during screw-down of the Abutment
Removal Driver, but don’t worry, simple exert is needed disconnect the abutment from the
fixture.

AnyRidge – 059
®
Characteristics & Advantages » Ⅳ. Maintenance

Ⅳ. Maintenance
Unique and sturdy design provides long-term stability!

AnyRidge 4.5 x 10mm Company OS

1. Higher cortical bone


AnyRidge 5.5 x 10mm Company NB
AnyRidge
45 does not depend on cortical bone
for initial stability; decreased stress(Fixture-Bone)
Stress Distribution on corti-
preservation is
Cortical Bone Thickness - 0.8mm
35
cal bone helps to prevent bone resorption
Cancellous bone level - D4

guaranteed after implantation.

Stress(MPa)
25

15

-5

AnyRidge 4.5 x 10mm Company OS • More0 cortical2 bone


Length (mm)
4 6

AnyRidge 5.5 x 10mm Company NB = More soft tissue volume


= Beautiful gingival line
45
Stress Distribution (Fixture-Bone)
Cortical Bone Thickness - 0.8mm
35 Cancellous bone level - D4
Advanced coronal design allows maximum
cortical bone preservation around implants.
Stress(MPa)

25 AnyRidge 4.5 x 10mm Beyond


Company OSosseointegration, AnyRidge can
AnyRidge 5.5 x 10mm assure beautiful gingival line by preserving
Company NB
45 4.5 x 10mm
15 AnyRidge Company OS and maintaining more cortical bone.
AnyRidge 5.5 x 10mm Stress Distribution (Fixture-Bone)
Company NB
Cortical Bone Thickness - 0.8mm- Round faced and narrow thread design
45 35 Cancellous bone level - D4
5
Stress Distribution (Fixture-Bone)
Stress(MPa)

Cortical Bone Thickness - 0.8mm


35 25
Cancellous bone level - D4
-5 AnyRidge EZ Plus Rescue
Performed
0 2
Finite element analysis 4
to evaluate the fixture-bone stress using 6
Stress(MPa)

ABAQUS
300.0 6.8 -R&D center15 in MegaGen Implant Co.,Ltd.(2009)-
25 Length (mm)
250.0

15 200.0
5
kgf

150.0 - Less insertion torque


5 -5
- Excellent initial stabilization
100.0 2 4 6
0 - Resistance to compressive force
-5 50.0 Length (mm) - Minimal Shear force creation

2 4 6 - Higher BIC
0 0.0
3.5
Length 4.0
(mm) 6.0 (n=8)
Diameter

- Round faced and narrow thread design

EZ Plus Rescue

- Round faced and narrow thread design

- Round faced and narrow thread design

AnyRidge EZ Plus Rescue


- Less insertion torque
0.0
Plus Rescue - Excellent initial stabilization
- Resistance to compressive force
0.0
- Minimal Shear force creation
0.0 - Higher BIC

0.0 4.0
Diameter
6.0 (n=8)
• A Human Biopsy
- Less insertion
(2.5 yrstorque
after placement)
- Excellent initial stabilization
0.0 The sharp and high alveolar crest (yellow arrow) could be maintained due
- Less insertion torque - Resistance to compressive force
to biology driven implant design. With this maintenance of alveolar bone,
0.0 - Excellent initial stabilization
- Minimal Shear force creation
the peri-implant marginal gingiva showed almost no recession during 2.5
- Resistance to compressive- forceHigher BIC
0.0 years of follow-up, even in the case of limited ridge width.
3.5 4.0 6.0 (n=8) - Minimal Shear force creation
Diameter - Higher BIC
.0 6.0 (n=8)
meter

060­
Fixture Product & Packaging » Ⅰ. Dimension

Fixture Product & Packaging


I. Dimension

Core Platform Bevel


(mm) (mm) (mm)

3.8
Ø3.3 3.5
4.0
Internal Hex : 2.3mm Platform Bevel Ø3.8 4.0 4.5
(Same in all fixtures) Diameter Diameter Ø4.0 4.25 4.75

Ø4.3 4.5 5.0

Ø4.8 5.0 5.5

Widest Thread
Diameter
Widest thread diameter is
Bevel Diameter 0.5mm wider than fixture size at 3.5mm
0.4mm wider than fixture size at 4.0~8.0mm
*For example
Platform Ø3.5 = Fixture diameter + 0.5mm
Diameter Ø4.0~Ø8.0 = Fixture diameter + 0.4mm

Core diameter
measured at 3.5mm Length
under the platform *Actual length of fixture
Core Ø3.3~4.3 fixture : 0.8mm shorter than the written length
Core Ø4.8 fixture : 0.6mm shorter than the written length

Core Important concept!


It has been proven that 0.5~1.0mm subcrestal placement
shows better crestal bone response.
With AnyRigde system, a fixture goes down to the ideal
position without further drilling avoiding damage to important
anatomic structures.

Female screw
1.8mm diameter X
Narrow apical 0.35mm pitch
Diameter
Ø3.5 : 1.6mm
Ø4.0~5.5 : 1.8mm
Ø6.0~8.0 : 3.0mm

Fixture Diameter [SEM image]

AnyRidge – 061
®
Fixture Product & Packaging » Ⅱ. Fixture Size

II. Fixture Size


Length
(mm)
4.0

Small Ø3.5 Fixture


Diameter (mm)
Core
(mm)
Length
(mm) Ref.C

- Cover Screw included.


7 FANIHX3507C
• Availability of 7mm product is subject to local 2.8
approval. 8.5 FANIHX3508C L

10 FANIHX3510C
3.5 2.8
11.5 FANIHX3511C
13 FANIHX3513C
3.5
15 FANIHX3515C

4.4

Regular Ø4.0 Fixture


Diameter (mm)
Core
(mm)
Length
(mm) Ref.C

- Cover Screw included.


7 FANIHX4007C
• Availability of 7mm product is subject to local 3.3
approval. 8.5 FANIHX4008C
L
10 FANIHX4010C
4.0 3.3
11.5 FANIHX4011C
13 FANIHX4013C
4.0
15 FANIHX4015C

4.9

Regular Ø4.5
Fixture Core
Diameter (mm) (mm)
Length
(mm) Ref.C
- Cover Screw included.
• Availability of 7mm product is subject to local
7 FANIHX4507C
3.3
approval. 8.5 FANIHX4508C
L
10 FANIHX4510C
3.3
11.5 FANIHX4511C
13 FANIHX4513C
4.5
15 FANIHX4515C
4.5
7 AR384507C
8.5 AR384508C
10 AR384510C
3.8
11.5 AR384511C
13 AR384513C
15 AR384515C

062­
Fixture Product & Packaging » Ⅱ. Fixture Size

➲ Fixture Size (Continued)

Wide Ø5.0 Fixture


Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
Fixture
Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
- Cover Screw included.
7 FANIHX5007C 7 FANIHX5007SC
5.4 8.5 FANIHX5008C 8.5 FANIHX5008SC
10 FANIHX5010C 10 FANIHX5010SC
3.3 4.0
3.3 11.5 FANIHX5011C 11.5 FANIHX5011SC

L 13 FANIHX5013C 13 FANIHX5013SC
15 FANIHX5015C 15 FANIHX5015SC
5.0 5.0
7 AR385007C 7 AR435007C

5.0 8.5 AR385008C 8.5 AR435008C

10 AR385010C 10 AR435010C
3.8 4.3
11.5 AR385011C 11.5 AR435011C

13 AR385013C 13 AR435013C

15 AR385015C 15 AR435015C

Wide Ø5.5 Fixture


Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
Fixture
Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
- Cover Screw included.
7 FANIHX5507C 7 AR435507C

5.9
8.5 FANIHX5508C 8.5 AR435508C

10 FANIHX5510C 10 AR435510C
3.3 4.3
3.3
11.5 FANIHX5511C 11.5 AR435511C

13 FANIHX5513C 13 AR435513C
L
15 FANIHX5515C 15 AR435515C
5.5
7 AR385507C 7 AR485507C

5.5
8.5 AR385508C 8.5 AR485508C

10 AR385510C 10 AR485510C
5.5 3.8 4.8
11.5 AR385511C 11.5 AR485511C

13 AR385513C 13 AR485513C

15 AR385515C 15 AR485515C

7 FANIHX5507SC

8.5 FANIHX5508SC

10 FANIHX5510SC
4.0
11.5 FANIHX5511SC

13 FANIHX5513SC

15 FANIHX5515SC

AnyRidge – 063
®
Fixture Product & Packaging » Ⅱ. Fixture Size

Super Wide Ø6.0


6.4
Fixture Core Length
Diameter (mm) (mm) (mm) Ref.C
- Cover Screw included.
7 AR406007C
8.5 AR406008C 4.8

4.0 10 AR406010C L

11.5 AR406011C
13 AR406013C
7 AR436007C 6.0

8.5 AR436008C
6.0 4.3 10 AR436010C
11.5 AR436011C
13 AR436013C
7 FALIHX6007C
8.5 FALIHX6008C
4.8 10 FALIHX6010C
11.5 FALIHX6011C
13 FALIHX6013C

Super Wide Ø6.5 Fixture Core


Diameter (mm) (mm)
Length
(mm) Ref.C
6.9

- Cover Screw included.


7 FALIHX6507C
8.5 FALIHX6508C 4.8
L
6.5 4.8 10 FALIHX6510C
11.5 FALIHX6511C
13 FALIHX6513C
6.5

Super Wide Ø7.0


7.4
Fixture Core Length
Diameter (mm) (mm) (mm) Ref.C
- Cover Screw included.
7 FALIHX7007C
4.8
8.5 FALIHX7008C
L
7.0 4.8 10 FALIHX7010C
11.5 FALIHX7011C
13 FALIHX7013C

7.0

064­
Fixture Product & Packaging » Ⅱ. Fixture Size

➲ Fixture Size

Super Wide Ø7.5 Fixture


Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
7.9

- Cover Screw included.


7 FALIHX7507C
8.5 FALIHX7508C 4.8

7.5 4.8 10 FALIHX7510C L

11.5 FALIHX7511C
13 FALIHX7513C
7.5

Super Wide Ø8.0 Fixture


Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
8.4

- Cover Screw included.


7 FALIHX8007C
8.5 FALIHX8008C 4.8

8.0 4.8 10 FALIHX8010C L

11.5 FALIHX8011C
13 FALIHX8013C
8.0

NEW
PRODUCT NEW PRODUCT
4.0 4.4 4.9 4.9
Special Length Fixture
Diameter (mm)
Core
(mm)
Length
(mm) Ref.C
- Cover Screw(cs) included
Ø3.5 3.3 AR333505C
3.3 3.3 3.3 3.8 7
Ø4.0 3.3 AR334005C
3.3 AR334505C 3.5 4.0 4.5 4.5
Ø4.5
3.8 AR384505C 5.4 5.4 5.4
3.3 AR335005C
Ø5.0 3.8 7 AR385005C 3.3 3.8 4.3 7
4.3 AR435005C
3.3 AR335505C 5.0 5.0 5.0
3.8 AR385505C 5.9 5.9 5.9 5.9
Ø5.5
4.3 AR435505C
4.8 AR485505C 3.3 3.8 4.3 4.8 7

5.5 5.5 5.5 5.5

For Irregular Ridge


"Special 7mm" Bevel
2mm This ‘Special 7mm’ fixture can
essential for special case
be used for non-uniform bone
loss case with limited available
5mm vertical dimension.
Ø3.5, Ø4.0, Ø4.5, Ø5.0, Ø5.5

Nerve 7mm Implant


5

AnyRidge – 065
®
Fixture Product & Packaging » Ⅲ. Packaging

Ⅲ. Packaging

- Ampule


Peel off cover & remove ampule ① ②


Separate top & bottom , as shown, to
Fixture reveal inner ampule with fixture


Cover Screw →

Flip open top to reveal fixture

Connect handpiece to fixture Make sure fixture is fully connected, then Place fixture according to drilling sequence
remove from ampule

Separate fixture ampule from bottom, as Use hand driver to pick up cover screw Tighten cover screw to fixture

shown, to reveal cover screw holder

MegaGen ampule! Re-usable as building block *after cleaning and sterilization! less plastic waste!

066­
Cover Screw & Healing Abutment

Cover Screw & Healing Abutment

Cover Screw Profile



Diameter
Height
(mm) Ref.C
P.D

Height
* Included in the fixture package. 0.8 AANCSF3508

• Use with a Hand Driver(1.2 Hex). Ø3.5 1.6 AANCSF3516


• Used for submerged type surgery.
2.6 AANCSF3526
• Protects the inner structure of a fixture.
• Different heights can be chosen according Ø5.0 0.5 AANCSF5005
to the position of fixture below the crest.
• 1.6mm and 2.6mm height of Cover Screw Ø6.0 0.5 AANCSF6005
can be purchased separately.
• Recommend torque : by hand (5 - 8Ncm)

P.D

Healing Abutment
• Use with a Hand Driver(1.2 Hex). H
• Used for non-submerged type surgery or for
two stage surgery. Platform
• Choose appropriate diameter and height of level
Healing Abutment according to situation.
• Helps to form suitable emergence profile
during period of gingival healing.
• Recommend torque : by hand (5 - 8Ncm)
Profile Height Profile Height
Diameter (mm) Ref.C Diameter (mm) Ref.C

3 0FAHN 403 3 0FAHN 703

4 0FAHN 404 4 0FAHN 704

5 0FAHN 405 5 0FAHN 705

4Ø 0. 6 0FAHN 406 7Ø 0. 6 0FAHN 706

7 0FAHN 407 7 0FAHN 707

8 0FAHN 408 8 0FAHN 708

9 0FAHN 409 9 0FAHN 709

3 0FAHN 503 3 0FAHN 803

4 0FAHN 504 4 0FAHN 804

5 0FAHN 505 5 0FAHN 805

5Ø 0. 6 0FAHN 506 8Ø 0. 6 0FAHN 806

7 0FAHN 507 7 0FAHN 807

8 0FAHN 508 8 0FAHN 808

9 0FAHN 509 9 0FAHN 809

3 0FAHN 603 3 1FAHN 003

4 0FAHN 604 4 1FAHN 004

5 0FAHN 605 5 1FAHN 005

6Ø 0. 6 0FAHN 606 1Ø 0.0 6 1FAHN 006

7 0FAHN 607 7 1FAHN 007

8 0FAHN 608 8 1FAHN 008

9 0FAHN 609 9 1FAHN 009

AnyRidge – 067
®
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

Abutment & Prosthetic Options


Ⅰ. Fixture Level Prosthesis

Zirconia Gold Abutment CCM Abutment EZ Post Abutment Milling Abutment Angled Abutment
Abutment

Temporary Abutment [Metal] Fuse Abutment

Lab Analog

Transfer Impression Impression Coping Impression Coping


Coping Driver [Transfer] [Pick-Up]
(Refer to Page.352 )

Cover Screw Healing Abutment

Abutment
Removal Driver
(Refer to Page.350)

068­
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Impression Copings

Impression Coping Profile Height


Diameter (mm) Type Ref.C

(2-piece, Transfer Type) Ø4.0


12 AANITH4012T

(For Closed-tray Technique) 16 AANITH4016T


2-Piece 16
• Streamlined shape ; easy to transfer. 12 AANITH5012T 12
• Anti-rotation grooves match with hex structure of fixtures. Ø5.0
16 AANITH5016T
• Should be tightened with Impression Driver 3
(Page.352) 12 AANITH4012HT Platform
• Special impression coping screw which can be Ø4.0 2-Piece level
used with a 1.2mm hex driver is available on 16 AANITH4016HT
Hand
request. 12 driver AANITH5012HT P.D
(1.2 Hex)
Ø5.0
16 AANITH5016HT

Impression Coping Profile Height


Diameter (mm) Type Ref.C

(1-piece, Transfer Type) Ø4.0


12 AANITN4012

(For Closed-tray Technique) 16 AANITN4016 16


1-Piece 12
• Should be tightened with Impression Driver 12 AANITN5012
(Page.352) Ø5.0
• Special impression coping screw which can be
16 AANITN5016
used with a 1.2mm hex driver is available on 12 AANITN4012H Platform
request. Ø4.0 level
1-Piece
16 AANITN4016H
Hand
12 driver AANITN5012H P.D
(1.2 Hex)
Ø5.0
16 AANITN5016H

Impression Coping Profile Height


Diameter (mm) Type Ref.C

(2-piece, Pick-up Type) 12 AANIPH4012T

(For Open-tray Technique) 16 AANIPH4016T


Ø4.0
- Guide Pins : AANGPP0010 (7mm : Short) / 12 AANIPN4012T
AANGPP0015 (12mm : Long) / AANGPP0020 16
(20mm : Extra-long) 16 AANIPN4016T
2-Piece 12
• Square structure ; strong anti - rotation function. 7 AANIPH5007T 7
• Designed for easy and accurate pick-up impression.
• Extra-long guide pin can be purchased separately. 12 AANIPH5012T
Ø5.0 Platform
7 AANIPN5007T level

12 AANIPN5012T P.D

AnyRidge – 069
®
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Lab Analog & Temporary Abutments

Lab Analog Profile Diameter Color Ref.C

Ø3.5 Magenta AANLAF35

Ø4.0 ~ Ø5.5 Blue AANLAF4055

Ø6.0 ~ Ø8.0 Yellow AALLAF6080

Hex Non-Hex

Temporary Abutment Profile Cuff Height


Diameter (mm) Type Ref.C

(Titanium) Hex AANTMH4012T 10


Ø4.0 2
- Multi Post Screw(AANMSF) included. Non-Hex AANTMN4012T
• For making provisional restoration.
• Grooved on the post allows strong resin 2
adherence. Platform
level
• Recommend torque : 25Ncm
Ø4.0

Milling

Fuse Abutment
Diameter
Labio-
lingual
Mesio-
distal
C.H
(mm)
P.H
(mm) Type Ref.C Ø5.0

- Straight, 15°, 25° ; Multi Post Screw(AANMSF) 15° 25°


included + Fuse Cap included. Ø5.5 5.5 Straight AFAP5545P
- Milling ; Multi Post Screw(AANMSF) included. Ø5.5 4 15° AFAA5415P P.H 11
Ø4.5 7
• Recommend torque : 25Ncm 25° AFAA5425P C.H
1
Ø5.0 1 11 Milling AANTAH5012T Platform
level

NEW : 4mm cuff height available Hex Hex

→ Adequate for deeply placed implants


or thick gingival cases

Mesio- Mesio-
distal distal

Labio-lingual Labio-lingual

070­
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

▸▸ Fuse Abutment ™
Why is the ‘Fuse Abutment’ essential partner for a temporary crown?

Various Angle :
Similar to a Straight 15° 25°
Design concept of customized abutment
Fuse Abutment™ for excellent esthetics!

Perfect margin fit


with a prosthetic cap
Scalloped outline

S-line

Mesio-distal

Labio-lingual

Elliptical Occlusal view


like a natural tooth

Rationale of In 1992, Brunski JB. reported that the of 100μm on a fixture which was placed se-
Fuse Abutment™ implant may has a higher possibility of curely into adequate density of bone without
fibrointergration than osseointegration defect. First, AnyRidge implants were placed
Micro-movement test of implant between bone and implant surface when into the internationally recognized standard
movements of more than100um occur on bone block with more 40Ncm torque force
0.5
the fixture during osseointegration period. and an abutment was connected on each im-
0.4 Fuse D1 (John B. Brunski, Biomechanical factors plant. Instron equipment was used to meas-
Displacement(mm)

Abutment
0.3
area D2
affecting the bone-dental implant interface. ure the force to move a fixture 100μm. The
D3
Clinical Materials, Vol. 10, 153-201) There- average force was 220N (22.4 kgf). Therefore,
0.2 D4
fore, the implant was needed to protected if the new temporary abutment can be fractur
0.1
not to move when immediate loading is under this force, it might protect the fixture
carried out. However, it is not easy to man- from movement or failure.
age loading on the fixture, even when we
0 50 100 150 200 250 300 350 400 450 500
Force(N)
Performed compressive strength test to evaluate the micro movement for used a resin temporarily with a titanium cyl-
bone density using universal testing machine inder. It was thought that it was partly be-
-R&D center in Megagen Implant Co.,Ltd.(2012)-
cause of the metal component of tempo-
Compressive strength test of Fuse Abutment rary cylinder, which can deliver excessive
forces to the fixture. This was one of the
250 reasons which made clinicians hesitate the
Compressive strength(N)

200 immediate loading procedure. So it was


150
necessary to develop a special temporary
Average < 180N cylinder. It should have been broken under
100
the force which could lead fibrointegration
Specimen 1
Specimen 2 From this experiment, we could developed a
50 Specimen 3
Specimen 4 or failure of osseointegration to protect special temporary abutment which has lower
0 1 2
Specimen 5
the fixture. and it would be preferred if it fracture threshold of less than 200 N (20.4
Displacement(mm) was easy to make a temporary crown on kgf). It was named as Fuse Abutment. Also it
Performed compressive strength test to evaluate the yield strength for
Fuse Abutment using universal testing machine
this particular temporary cylinder. We tried has an anatomic profiles to make temporary
-R&D center in Megagen Implant Co.,Ltd.(2012)- to measure the force causing movement prosthetics more esthetic.

AnyRidge – 071
®
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Abutment Options (Continued)

Hex Non-Hex

EZ Post Abutment
- Multi Post Screw(AANMSF/AANMST) included.
P.H
• Use with a Hand Driver (1.2 Hex).
• Esthetic gold coloring.
• Two different post heights. (5.5, 7.0mm)
• Four different profile diameters. C.H
(Ø4.0, 5.0, 6.0, 7.0)
Platform
• Four different cuff heights. level
(2.0, 3.0, 4.0, 5.0mm)
• Recommend torque : 35Ncm
P.D

Profile Cuff Post Type Ref.C Profile Cuff Post Type Ref.C
Diameter Height(mm) Height(mm) Diameter Height(mm) Height(mm)

2 4HPENA 025L 2 6HPENA 025L

3 4HPENA 035L 3 6HPENA 035L


5.5 5.5
4 4HPENA 045L 4 6HPENA 045L

5 4HPENA 055L 5 6HPENA 055L


4Ø 0. xeH 6Ø 0. xeH
2 4HPENA 027L 2 6HPENA 027L

3 4HPENA 037L 3 6HPENA 037L


7 7
4 4HPENA 047L 4 6HPENA 047L

5 4HPENA 057L 5 6HPENA 057L

2 4NPEA 025L 2 6NPEA 025L

3 4NPEA 035L 3 6NPEA 035L


5.5 5.5
4 4NPEA 045L 4 6NPEA 045L

5 4NPEA 055L 5 6NPEA 055L


4Ø 0. xeH-noN 6Ø 0. xeH-noN
2 4NPEA 027L 2 6NPEA 027L

3 4NPEA 037L 3 6NPEA 037L


7 7
4 4NPEA 047L 4 6NPEA 047L

5 4NPEA 057L 5 6NPEA 057L

2 5HPENA 025L 2 7HPENA 025L

3 5HPENA 035L 3 7HPENA 035L


5.5 5.5
4 5HPENA 045L 4 7HPENA 045L

5 5HPENA 055L 5 7HPENA 055L


5Ø 0. xeH 7Ø 0. xeH
2 5HPENA 027L 2 7HPENA 027L

3 5HPENA 037L 3 7HPENA 037L


7 7
4 5HPENA 047L 4 7HPENA 047L

5 5HPENA 057L 5 7HPENA 057L

2 5NPEA 025L 2 7NPEA 025L

3 5NPEA 035L 3 7NPEA 035L


5.5 5.5
4 5NPEA 045L 4 7NPEA 045L

5 5NPEA 055L 5 7NPEA 055L


5Ø 0. xeH-noN 7Ø 0. xeH-noN
2 5NPEA 027L 2 7NPEA 027L

3 5NPEA 037L 3 7NPEA 037L


7 7
4 5NPEA 047L 4 7NPEA 047L

5 5NPEA 057L 5 7NPEA 057L

072­
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Abutment Options (Continued)

Hex Non-Hex

Gold Abutment Profile Cuff


Post
Diameter Height(mm) Height(mm)
Type Ref.C

- Multi Post Screw(AANMSF/AANMST) included. Hex AANGAH4012L


Ø4.0 1 11 P.H
• Useful to make a customized abutment in Non-Hex AANGAN4012L
difficult situations.
• Precious and non-precious alloys.
• Melting point of gold alloy : 1400 - 1450℃ C.H
• Threaded sleeves for convenient Resin / Wax-up. Platform
• Recommend torque : 30Ncm level
P.D

Hex
Zirconia Abutment Profile Cuff
Post
Diameter Height(mm) Height(mm)
Type Ref.C

- Multi Post Screw(AANMSF/AANMST) included. Ø4.0 AANZAH4012L


1 11 Hex P.H
• For esthetic use. Ø5.0 AANZAH5012L
• Natural white color with pre-sintered zirconia
sleeve. C.H
• Presinpered Zircornia Abutment. Platform
level
• Preparable at the chair side with a diamond bur. P.D
• Recommend torque : 35Ncm

Milling Abutment Profile Cuff Post


Diameter Height(mm) Height(mm) Ref.C

- Multi Post Screw(AANMSF/AANMST) included. 2 4HAMN 029L


• Long post enables easier customization from
3 4HAMN 039L
milling. 4Ø 0. 9
• Recommend torque : 35Ncm 4 4HAMN 049L

5 4HAMN 059L

2 5HAMN 029L
P.H
3 5HAMN 039L
5Ø 0. 9
4 5HAMN 049L C.H
5 5HAMN 059L Platform
level
2 6HAMN 029L P.D

3 6HAMN 039L
6Ø 0. 9
4 6HAMN 049L

5 6HAMN 059L

2 7HAMN 029L

3 7HAMN 039L
7Ø 0. 9
4 7HAMN 049L

5 7HAMN 059L

AnyRidge – 073
®
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

Ø4.0

Milling Abutment Type II Profile


Diameter
Cuff Post
Height(mm) Height(mm) Type Ref.C
(BOPT Abutment)
Hex ARBOT4019HL 19
Ø4.0 1 19
- AnyRidge Internal : Multi Post Screw (AANMSF/ Non-Hex ARBOT4019NL
AANMST) included.
1
• Long post enables easier customization from
milling.
• Recommend torque : 35Ncm

B.O.P.T (Biologically OrientedPreparation Technique)


MegaGen family thanks to MD. Oscar Alonso Gonzalez
& Dr. Fabio Galli for the suggestion of B.O.P.T abutment

- To obtain thick, healthy and stable Fig 1. With its divergent


soft tissue anround tooth profile, it tends to sta-
bilize the circular fibers
of the connective tissue
towards apical.

Fig 2. In the same way


as with the teeth, this
Characteristics of B.O.P.T abutment facilitates
1. Morphology without a finish line. the stabilization of the
circular fibers of the
2. Conical Shape.
Fig 1 Fig 2
connective tissue at
3. Prosthetic Platform Switching a more coronal level
compared to a standard
rehabilitation.

B.O.P.T Clinical Case - Courtesy of Dr. Fabio Galli

Case 1.

Case 2.

Case 3.

Implant Placement Post-op panoramic view Final Restoration 4 years F/U

074­
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Abutment Options (Continued)

Hex-E Hex

Angled Abutment 15° 25° 15° 25°

- Multi Post Screw(AANMSF/AANMST) included.

• Two different angulations. (15°, 25°)


P.H
• Four different profile diameters.
(Ø4.0, 5.0, 6.0, 7.0)
• Four different cuff heights. (2, 3, 4, 5mm)
• Can cover 12 different directions. C.H
[six to the surface(Hex), six to the edge of Platform
hex(Hex-E)] level
• Esthetic gold coloring.
• Minimized screw head length needs minimum
P.D
height to prevent milling problems.
• Recommend torque : 35Ncm

Profile Cuff Post Profile Cuff Post


Diameter Height(mm) Height(mm) Type Angle Ref.C Diameter Height(mm) Height(mm) Type Angle Ref.C

2 4HAN 215L 2 6HAN 215L


3 4HAN 315L 3 6HAN 315L
xeH xeH
4 4HAN 415L 4 6HAN 415L
5 4HAN 515L 5 6HAN 515L
15° 15°
2 4EAN 215L 2 6EAN 215L
3 4EAN 315L 3 6EAN 315L
E-xeH E-xeH
4 4EAN 415L 4 6EAN 415L
5 4EAN 515L 5 6EAN 515L
4Ø 0. 7 6Ø 0. 7
2 4HAN 225L 2 6HAN 225L
3 4HAN 325L 3 6HAN 325L
xeH xeH
4 4HAN 425L 4 6HAN 425L
5 4HAN 525L 5 6HAN 525L
25° 25°
2 4EAN 225L 2 6EAN 225L
3 4EAN 325L 3 6EAN 325L
E-xeH E-xeH
4 4EAN 425L 4 6EAN 425L
5 4EAN 525L 5 6EAN 525L
2 5HAN 215L 2 7HAN 215L
3 5HAN 315L 3 7HAN 315L
xeH xeH
4 5HAN 415L 4 7HAN 415L
5 5HAN 515L 5 7HAN 515L
15° 15°
2 5EAN 215L 2 7EAN 215L
3 5EAN 315L 3 7EAN 315L
E-xeH E-xeH
4 5EAN 415L 4 7EAN 415L
5 5EAN 515L 5 7EAN 515L
5Ø 0. 7 7Ø 0. 7
2 5HAN 225L 2 7HAN 225L
3 5HAN 325L 3 7HAN 325L
xeH xeH
4 5HAN 425L 4 7HAN 425L
5 5HAN 525L 5 7HAN 525L
25° 25°
2 5EAN 225L 2 7EAN 225L
3 5EAN 325L 3 7EAN 325L
E-xeH E-xeH
4 5EAN 425L 4 7EAN 425L
5 5EAN 525L 5 7EAN 525L

Hex Non-Hex

CCM Abutment Profile Cuff Post


Diameter Height(mm) Height(mm) Type Ref.C

- Multi Post Screw(AANMSF/AANMST) included. Hex AANCAH4012L


Ø4.0 1 11
• Useful to make a customized abutment in difficult Non-Hex AANCAN4012L P.H
situations.
• Can be casted with non-precious alloys
(Ni-Cr, Cr-Co alloys).
C.H
• Non-precious melting temperature : Depend on Platform
Manufacturer level
• Threaded sleeves for convenient Resin / Wax-up. P.D
• Melting temperature of CCM : 1380 - 1420℃
• Recommend torque : 35Ncm
AnyRidge – 075
®
Ⅰ. Fixture Level Prosthesis
1. Fixture Level Prosthesis_Extra EZ Post
Milling Type EZ Post Type

Burn-out Cylinder Extra EZ Post Extra EZ Post ZrGEN Abutment TiGEN Abutment
Abutment Abutment Extra type Extra type

Lab Analog Temporary Abutment


[Extra type]

Comfort Cap Snap Impression Coping Lab Analog

Extra EZ Post Impression Coping Scan Abutment


Abutment

Cover Screw Healing Abutment Scan Healing Abutment Scan Post


[Extra type] [Extra type] [Extra type]

076­
Le
t’s
S2 Option for successful 'second molar implant' re
m
in
AnyRidge challenges to the HIGH SURVIVAL RATE even at the second molar d!

You may already know that


'second molar Implant' has much less success rate than others
1) Simple Literature Reviews:
<General Implant success rate> <Second molar Implant Success rate>
99.7% - 10-year survival rate at implant  “89.0%” – CSR of 392 implants in the posterior mandible for 6 yrs
- van Velzen FJ et al. (2014) - Parein et al. (1997)

95.6%, 94.4%, 96.1%, 100%, 90.6%, 95.7% - CSR “91.1%” - 2 Molar survival Rate for 2 yrs - YK kim et al. (2010)
nd

of 759 implants in single-tooth prostheses, cantilever fixed,


“82.9%”, “91.5%” - Prospective study on 282 implants
partial prostheses, fixed partial prostheses, fixed complete
placed in the Mx and Mn molar position (6 years cumulative
prostheses, implant/tooth-connected prostheses, and over-
study) Becker et al. (1999)
dentures – Romeo E et al. (2004)
8.16% failure in the Mx, 4.93% in the Mn - Moy et al (2005)

m n
le io
ob lut
Pr So
2) Why less success rate at 3) How to overcome
the Second Molar? less success rate?
Handicaps of the Second Molar Implant ; Possible solution

1. Less quality & quantity of alveolar bone - We need an implant system which can provide ex-
- Maxillary 2 Molar site usually show less quality
nd
cellent initial stability① even at the loose bone
(Type Ⅳ or worse) and/or limited height due to Sinus and limited height of bone.
pneumatization. - We need an implant system which can provide
- Mandible 2 Molar site usually show less blood sup-
nd
enough surface area② for osseointegration,
ply which is important for adeguate alveolar bone me- even at the limited height of bone.
tabolism.And limited height of bone due to the inferior - We need to provide enough space for angio-
mandibular nerve. genesis and blood supply③ for more active
bone remodeling.
2. Strong Occlusal force
Due to special joint system at TMJ, the Second Molar We need stronger
implant fixture and abut-
usually endure strong occlusal force during mastication. ment connection④ to withstand occlusal forces
and lateral movement.
3. Hygiene Problem
Due to remote position, it’s very difficult to maintain hygiene We need to choose adequate material⑤ for abut-
at the second Molar, especially a t the distal area, So easy ment and crown, which retains much less plaque, even with
to get peri-implantitis than others. less accessibility and hygiene skills.

4) MegaGen's suggestion for the second molar implant


“S2 Option” strongly recommended by KOLs of MegaGen.
① Excellent initial stability at loose bone Already well-know advantages of AnyRidge Implant System.
② Enough surface area for osseointegration

81

80
ISQ Value

79

78

77

76
T0 T1 T2 T3 T4 T5 T6 T7 T8
AR
Follow-up Interval EZ

[Surface area comparison between AnyRidge and EZ plus] [ISQ value comparison between AnyRidge and EZ plus]

AnyRidge – 077
®
Le
t’s
re
m
in
d!

You may already know that


'second molar Implant' has much less success rate than others
2 molar immediate placement case
nd

Fig.1 After extraction Fig.2 Immediate placement Fig.3 Final restoration Fig.4 7yr F/U
- 4
 .8 core diameter and deep thread AnyRidge implant will create very strong and satisfactory initial stability at the large extraction
socket of second molar.
- Courtesy of Dr. Kwang Bum Park

③ Enough space for angiogenesis and blood supply through the inter-thread space
- Knife thread design of AnyRidge implant creates the maximum space for blood supply
0.530㎟

0.127㎟
4.17times

Enough space for


Angiogenesis and blood supply

[AnyRidge] [EZ Plus]


④ Stronger fixture and abutment connection
Fixture Selection
- For the strength of successful second molar implant, our KOLs strongly recommend to use ‘Core Diameter’ widen than
3.8mm.
- If there is enough width of bone, 4.3mm or 4.8mm core AnyRidge fixture would be better.
- At the large extraction socket of second molar, we recommend 4.8mm core and deep thread AnyRidge implant.

Core Fixture Diameter


Diameter Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø5.5 Ø6.0 Ø6.5 Ø7.0 Ø7.5 Ø8.0

2.8
Thread depth 0.3

3.3
Thread depth 0.35 0.6 0.85 1.1

3.8
Thread depth 0.35 0.6 0.85 S2 Option

4.0
Thread depth 0.45 0.7 0.95

4.3
Thread depth 0.35 0.6 0.85

4.8
Thread depth 0.35 0.6 0.85 1.1 1.35 1.6
Refer to page. 055

078­
Le
t’s
re
m
in
d!

Abutment Selection
- 5º AnyRidge connection is really strong and shows almost no biological width.
- Double offset (Implant switching and Abutment switching) is very helpful to improve soft tissue esthetics and health.
- However, at the second molar implant, the strength against lateral occlusal force is more critical than esthetics.
- So our KOLs strongly recommend to use ‘Extra EZ Connection’ for abutment.


[ Normal connection ] [ S2 Option : Double connection ]

Flat-to-Flat connection
at the platform
Compressive
Double offset strength
is improved
by 5º internal connection

67%
maintained

This ‘Double connection’ has double advantages.


1. Strong resistance to lateral occlusal forces
2. No sinking of prosthetics
- Most of internal connection shows 30~50㎛ of sinking following delivery of crown
- S2 Option will not show sinking phenomenon, while maintaining the 5º internal connection

⑤ Adequate material for hygiene


Our KOLs recommend zirconia customized abutment and/or zirconia monolithic crown for the second molar implant.

Bacterial Adhesion on Commercially Pure Titanium and Zirconium Oxide Disks: An In Vivo Human Study
Bioinert Bioaffinity Antonio Scarano, Maurizio Piattelli, Sergio Caputi, Gian Antonio Favero, and Adriano Piattelli JP 2004
The mucosal barrier at implant abutments of different materials
Maria Welander, Ingemar Abrahamsson, Tord Berglundh COIR19, 2008; 635–641

ZrGEN(Extra EZ)
ZrGEN is the brand name of Mega-
Gen Titanium Base. The strength of
ZrGEN frees you from the chipping
to conventional PFM prosthesis.
Monolithic zirconia crowns have no
metal substructure,
enhancing better survival rate !
Titanium. A homogeneous layer of cocci or fila- Zirconium oxide. A small number of bac- (from left: Ti, ZrO2, Ti, Au/Pt-alloy) in place 1 month
mentous bacteria covers the titanium surface teria cover the zirconium oxide surface. after implant placement

- However, the Zirconia customized abutment has limitations on strength which leads fracture of zirconia and/or cement-break
between ti-insert and Zirconia abutment.
- So MegaGen developed new ‘Ti-insert’ for the stronger customized abutment!
Ø5.5
Ø4.25
Ø4
Ø3.15
Groove
Post height
(4.5, 6/ 8 mm)
Post height
(4.5 & 6 mm)

Cuff height
Cuff height
(0.6 & 1.5mm)
(0.6, 1.5/ 3 & 4 mm)

new ‘Ti-insert’

AnyRidge – 079
®
Le
t’s
re
m
S2 Option with AnyRidge Clinical Case in
d!

➲ Clinical Case 1
- Courtesy of Dr. Seung Yeup Lee

S2 Option Line-up with AnyRidge implant can be the best solution in posterior zone

Fig 1. Initial Photo

Fig 2. Harvest Autogenous Bone

Fig 3. Implant placement

Fig 4. Provisionalization
Fig 1 Fig 2 Fig 3

Fig 5, 6. Before / After Surgery

Fig 7. Final Delivery

Fig 8. 6 yrs F/U

Fig 4 Fig 5 Fig 6

Fig 7 Fig 8

➲ Clinical Case 2
- Courtesy of Dr. Seung Yeup Lee

S2 Option Line-up with AnyRidge implant can be the best solution in posterior zone

Fig 1. Intra Oral before surgery

Fig 2. Panorama view

Fig 3. After Implant Placement

Fig 4. Connect Extra EZ-Post


Fig 1 Fig 2

Fig 5. Zirconia Customized Abutment


using ZrGen

Fig 6, 7. Connect PMMA

Fig 3 Fig 4

Fig 5 Fig 6 Fig 7

080­
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Extra EZ Post Abutment

Extra EZ Post Abutment 5.5 5.5

- Multi Post Screw(AANMSF/AANMST) included.


• Useful when fixture is exposed over the gum line. C C
• Recommend torque : 35Ncm
Platform Platform
level level
D D
Bevel Platform

EZ Post Type
Core Profile Cuff Type Ref.C Core Profile Cuff Type Ref.C
Diameter Diameter Diameter Diameter

2 5HENRA 025L 2 6HERA 025L

3 5HENRA 035L 3 6HERA 035L


xeH xeH
4 5HENRA 045L 4 6HERA 045L

5 5HENRA 055L 5 6HERA 055L


5Ø 0. 6Ø 0.
2 5NERA 025L 2 6NERA 025L
3 5NERA 035L 3 6NERA 035L
xeH-noN xeH-noN
4 5NERA 045L 4 6NERA 045L

5 lev B 5NERA 055L 5 mroftalP 6NERA 055L


3Ø 3. 4Ø 0.
2 6HENRA 025L 2 7HERA 025L

3 6HENRA 035L 3 7HERA 035L


xeH xeH
4 6HENRA 045L 4 7HERA 045L

5 6HENRA 055L 5 7HERA 055L


6Ø 0. 7Ø 0.
2 6NERA 025L 2 7NERA 025L

3 6NERA 035L 3 7NERA 035L


xeH-noN xeH-noN
4 6NERA 045L 4 7NERA 045L

5 6NERA 055L 5 7NERA 055L

Milling Type 5.5 5.5 6.5

Core Profile Cuff Post Type Ref.C


Diameter Diameter Height Height P.H
3Ø 3. 5Ø 5. lev B 3HENA 335L

4Ø 0. 5Ø 5. 3 5.5 4HENA 035L C.H


mroftalP Platform
4Ø 8. 6Ø 5. 4HENA 835L level
Bevel Platform Platform
• AANEEH3335 used for fixture (Ø4.0~5.5)
• AANEEH4035 used for fixture (Ø5.0, Ø5.5_Core ø4)
-A
 ANEEH4035 is for the Core Diameter ø4.0mm (Fixture Diameter
Ø5.0~5.5mm). It also can be used for Fixture Diameter Ø6.0~8.0mm
for platform switching.
• AANEEH4835 used for fixture (Ø6.0~8.0)
• Recommend torque : 35Ncm

AnyRidge – 081
®
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Components for Extra EZ Post Abutment

Core Profile D
Cover Screw Diameter Diameter Type Ref.C
1
3Ø 3. 4Ø 0. lev B 4FSCNA 008
(Extra Type)
4Ø 0. 4Ø 2. 5 mroftalP 4FSCNA 208
- Included in the fixture package.

• Use with a Hand Driver(1.2 Hex).


• Used for submerged type surgery.
• Protects the inner structure of a fixture.
• Different heights can be chosen according
to the position of fixture below the crest.
• 1.6mm and 2.6mm height of Cover Screw
can be purchased separately.
• Recommend torque : by hand (5 - 8Ncm)

Extra Healing Abutment Core Profile Height


Diameter Diameter (mm)
Type Ref.C

• Use with a Hand Driver(1.2 Hex). 3 5AHENR 03


• Used for non-submerged type surgery or for two 4 5AHENR 04
stage surgery.
5Ø 0. 5 5AHENR 05 D D
• Choose appropriate diameter and height of
Heal- ing Abutment according to situation. 6 5AHENR 06
• Helps to form suitable emergence profile during 7 5AHENR 07 H H
period of gingival healing. 3Ø 3. lev B
3 6AHENR 03
• Recommend torque : by hand (5 - 8Ncm) Platform
4 6AHENR 04 level
6Ø 0. 5 6AHENR 05
6 6AHENR 06 Bevel Platform
7 6AHENR 07
3 4AHER 03
4 4AHER 04
4Ø 2. 5 4AHER 05
6 4AHER 06
7 4AHER 07
3 6AHER 03
4 6AHER 04
4Ø 0. 6Ø 0. 5 6AHER 05
mroftalP
6 6AHER 06
7 6AHER 07
3 7AHER 03
4 7AHER 04
7Ø 0. 5 7AHER 05
6 7AHER 06
7 7AHER 07
4Ø 8. 6Ø 5. 4 4FAHN 84

Lab Analog Profile Diameter Color Ref.C

Ø4.0 ~ Ø5.5 Blue AANLAF4055

Ø6.0 ~ Ø8.0 Yellow AALLAF6080

082­
Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

Impression Coping
Profile Height
Diameter (mm) Type Ref.C

(2-piece, Transfer Type) Ø4.0


12 AANITH4012T
16
(For Closed-tray Technique) 16 AANITH4016T 12
2-Piece
• Streamlined shape ; easy to transfer. 12 AANITH5012T
Ø5.0 3
• Anti-rotation grooves match with hex structure of fixtures.
16 AANITH5016T Platform
• Should be tightened with Impression Driver
level
(Page.352) 12 AANITH4012HT
• Special impression coping screw which can be Ø4.0 2-Piece
used with a 1.2mm hex driver is available on 16 AANITH4016HT P.D
Hand
request. 12 driver AANITH5012HT
(1.2 Hex)
Ø5.0
16 AANITH5016HT

Impression Coping
Profile Height
Diameter (mm) Type Ref.C

(1-piece, Transfer Type) Ø4.0


12 AANITN4012

(For Closed-tray Technique) 16 AANITN4016 16


1-Piece 12
• Should be tightened with Impression Driver 12 AANITN5012
(Page.352) Ø5.0
• Special impression coping screw which can
16 AANITN5016
be used with a 1.2mm hex driver is available 12 AANITN4012H Platform
on request. Ø4.0 level
1-Piece
16 AANITN4016H
Hand
12 driver AANITN5012H P.D
(1.2 Hex)
Ø5.0
16 AANITN5016H

Impression Coping
Profile Height
Diameter (mm) Type Ref.C

(2-piece, Pick-up Type) 12 AANIPH4012T

(For Open-tray Technique) 16 AANIPH4016T


Ø4.0
- Guide Pins : AANGPP0010 (7mm : Short) / 12 AANIPN4012T
AANGPP0015 (12mm : Long) / AANGPP0020 16
(20mm : Extra-long) 16 AANIPN4016T
2-Piece 12
• Square structure ; strong antirotation function. 7 AANIPH5007T 7
• Designed for easy and accurate pick-up impression.
• Extra-long guide pin can be purchased separately. 12 AANIPH5012T
Ø5.0 Platform
7 AANIPN5007T level

12 AANIPN5012T P.D

Temporary Abutment
Hex Non-Hex
Core Profile Type
Diameter Diameter Mount Connection Ref.C

(Titanium Extra Type) Hex ARNTAH4510T


Ø3.3 Ø4.5 Bevel 10
- fixture package included. Non-Hex ARNTAN4510T
• Use with a Hand Driver(1.2 Hex).
Hex ARRTAH4710T
• Used for submerged type surgery. Ø4.0 Ø4.75 Platform 2
• Protects the inner structure of a fixture. Non-Hex ARRTAN4710T Platform
• Different heights can be chosen according level
to the position of fixture below the crest.
Ø4.5
• 1.6mm and 2.6mm height of Cover Screw
can be purchased separately.
• Recommend torque : by hand (5 - 8Ncm)
AnyRidge – 083
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Ⅱ. Abutment Level Prosthesis


1. Solid Abutment & Components

Burn-out Cylinder

Lab Analog

Comfort Cap Snap Impression Coping

Solid Driver Solid Abutment


(Refer to Page.352)

Cover Screw Healing Abutment

Hand Driver 1.2 Hex


(Refer to Page.349)

084­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Solid Abutment Option

Solid Abutment
• Used in cement retained restoration only.
• Solid Abutment should be placed into patient’s
P.H
mouth before taking impression.
• Onebody (screw + abutment)
• Should be tightened with a Solid Driver and a
Torque Wrench : 35Ncm C.H
• Four different profile diameters. (Ø4.0/5.0/6.0/7.0) Platform
level
- Should be tightened with special Solid Driver.
- Wider profile has bigger post angulation.
(4mm - 8°, 5mm - 10°, 6mm - 12°, 7mm - 14°)
• Four different cuff heights. (2/3/4/5mm)
P.D
• Three different post heights. (4/5.5/7mm)
• Recommend torque : 35Ncm

Profile Cuff Post Profile Cuff Post


Diameter Height(mm) Height(mm) Ref.C Diameter Height(mm) Height(mm) Ref.C

2 4LASN 024 2 6LASN 024

3 4LASN 034 3 6LASN 034


4 4
4 4LASN 044 4 6LASN 044

5 4LASN 054 5 6LASN 054

2 4LASN 025 2 6LASN 025

4Ø 0. 3 4LASN 035 6Ø 0. 3 6LASN 035


5.5 5.5
4 4LASN 045 4 6LASN 045

5 4LASN 055 5 6LASN 055

2 4LASN 027 2 6LASN 027

3 4LASN 037 3 6LASN 037


7 7
4 4LASN 047 4 6LASN 047

5 4LASN 057 5 6LASN 057

2 5LASN 024 2 7LASN 024

3 5LASN 034 3 7LASN 034


4 4
4 5LASN 044 4 7LASN 044

5 5LASN 054 5 7LASN 054

2 5LASN 025 2 7LASN 025

3 5LASN 035 3 7LASN 035


5Ø 0. 5.5 7Ø 0. 5.5
4 5LASN 045 4 7LASN 045

5 5LASN 055 5 7LASN 055

2 5LASN 027 2 7LASN 027

3 5LASN 037 3 7LASN 037


7 7
4 5LASN 047 4 7LASN 047

5 5LASN 057 5 7LASN 057

AnyRidge – 085
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Solid Abutment (Continued)

Snap Impression Coping Profile Diameter Ref.C


• For impression on Solid Abutments.
• 3 colors for different post heights. AANSIF440
• 4 different diameters for profile diameters.
Ø4.0 AANSIF455
(Ø4, 5, 6, 7)
• Do not use when abutment is trimmed.
AANSIF470

AANSIF540

Ø5.0 AANSIF555

AANSIF570

AANSIF640

Ø6.0 AANSIF655

AANSIF670

AANSIF740

Ø7.0 AANSIF755

AANSIF770
7

P.D

Comfort Cap Profile Diameter Post Height(mm) Ref.C

• Protects the Solid Abutment and minimizes 4 AANCCF440


irritation to tongue and oral mucosa.
• Can be applied under temporary prosthetics. Ø4.0 5.5 AANCCF455
• Color coded according to post heights.
7 AANCCF470

4 AANCCF540

Ø5.0 5.5 AANCCF555

7 AANCCF570

4 AANCCF640

Ø6.0 5.5 AANCCF655

7 AANCCF670

4 AANCCF740
P.H
Ø7.0 5.5 AANCCF755

7 AANCCF770 P.D

086­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Solid Abutment

Lab Analog Profile Diameter Height(mm) Ref.C

• Directly connected to the Snap Impression Coping 4 AANSLF440


in the impression to make a stone model.
Ø4.0 5.5 AANSLF455

7 AANSLF470

4 AANSLF540
H
Ø5.0 5.5 AANSLF555

7 AANSLF570

4 AANSLF640

Ø6.0 5.5 AANSLF655

7 AANSLF670
P.D
4 AANSLF740

Ø7.0 5.5 AANSLF755

7 AANSLF770

Burn-out Cylinder Profile Diameter Type Ref.C

• Fits with a Lab Analog(solid level). Ø4.0 AANBCB470


• Easy to wax-up and accurate casting.
• White Cylinder for multiple unit. Ø5.0 AANBCB570
• Red Cylinder for single crown. Multiple
Ø6.0 AANBCB670

Ø7.0 AANBCB770

Ø4.0 AANBCS470

Ø5.0 AANBCS570
Single
Ø6.0 AANBCS670 P.D

Ø7.0 AANBCS770

AnyRidge – 087
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Ⅱ. Abutment Level Prosthesis


2. Octa Abutment & Components

Gold Cylinder Plastic Cylinder CCM Cylinder EZ Post Cylinder

Temporary Cylinder

Lab Analog

Impression Coping Impression Coping


[Transfer] [Pick-Up]

Octa Abutment Healing Cap


(Refer to Page.89)

Cover Screw Healing Abutment

088­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Octa Abutment (Continued)

P.D

Octa Abutment Profile Diameter Cuff Height


(mm)
Ref.C
C.H
• Used in manufacturing multiple screw-retained 1 AANOAF4010
Platform
prosthetics. level
2 AANOAF4020
• Recommend torque : 35Ncm
• Maximum path angle : 70˚ Ø4.0 3 AANOAF4030

4 AANOAF4040
Ø4.0 Ø5.0 Ø6.0
5 AANOAF4050

1 AANOAF0010
C.H
2 AANOAF0020 Platform
level
Ø5.0 3 AANOAF0030

4 AANOAF0040

5 AANOAF0050

1 AANOAF6010

2 AANOAF6020

Ø6.0 3 AANOAF6030

4 AANOAF6040

5 AANOAF6050

Healing Cap Profile Diameter Ref.C

- Cylinder Screw(IRCS200) included.


Ø4.0 AANOHC4000T

• Protects Octa Abutment and minimizes irritation Ø5.0 IHC400T


to tongue and oral mucosa. Ø6.0 AANOHC6000T
P.D

AnyRidge – 089
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Octa Abutment

Octa Non-Octa

Impression Coping Profile Height


Diameter (mm) Type Ref.C
Octa Non-Octa

(Transfer) 7.5
Octa AAOITO4010T

- Guide Pin(AAOTGP10 / AAOTGP12) included.


Non-Octa AAOITN4010T
Ø4.0
Octa AAOITO4012T Ø4.0
• Should be tightened with Impression Driver 9.5
Non-Octa AAOITN4012T Octa Non-Octa 2.5
(Page.256) Octa Non-Octa
• Special impression coping screw which can be Octa AAOITO5010T
used with a 1.2mm hex driver is available on
7.5
Non-Octa AAOITN5010T 7.5 9.5
request. Ø5.0
Octa AAOITO5012T
9.5
Non-Octa AAOITN5012T Ø5.0 Ø5.0
Octa AAOITO6010T Octa Non-Octa
7.5 Octa Non-Octa
Non-Octa AAOITN6010T
Ø6.0
Octa AAOITO6012T
9.5
Non-Octa AAOITN6012T

Ø6.0

Octa Non-Octa
Octa Non-Octa

Impression Coping Profile Height


Diameter (mm) Type Ref.C
12
10
(Pick-Up) 10.0
Octa AAOIPO4010T

- Guide Pin(AAOPGP10 / AAOPGP12) included. Non-Octa AAOIPN4010T


Ø4.0
Octa AAOIPO4012T Ø4.0
12.0 Octa Non-Octa
Non-Octa AAOIPN4012T Octa Non-Octa

Octa AAOIPO5010T
10.0
Non-Octa AAOIPN5010T
Ø5.0
Octa AAOIPO5012T
12.0
Ø5.0
Non-Octa AAOIPN5012T

Octa AAOIPO6010T Octa Non-Octa


Octa Non-Octa
10.0
Non-Octa AAOIPN6010T
Ø6.0
Octa AAOIPO6012T
12.0
Non-Octa AAOIPN6012T

Ø6.0

090­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

3.8 4.8 5.8


Lab Analog Profile Diameter Ref.C

Ø3.8 AANOLA4000

Ø4.8 IOA300

Ø5.8 AANOLA6000

Temporary Cylinder Profile Type


Diameter
Ref.C

- Cylinder Screw(IRCS200) included. Octa AANOTCO4010T


Ø4.0 Octa Non-Octa Octa Non-Octa Octa Non-Octa
Non-Octa AANOTCN4010T
• Recommend torque : 25Ncm
Octa AANOTCO5010T
Ø5.0
Non-Octa AANOTCN5010T
Octa AANOTCO6010T
Ø6.0 Ø4.0 Ø5.0 Ø6.0
Non-Octa AANOTCN6010T

EZ Post Cylinder Profile Post


Type Ref.C Octa Non-Octa
Diameter Height(mm)

- Cylinder Screw(IRCS200) included. 5.5 AAOECO4005T


Octa 7.0
5.5
7.0 AAOECO4007T
• Recommend torque : 35Ncm Ø4.0
5.5 AAOECN4005T Ø4.0
Non-Octa
7.0 AAOECN4007T
Octa Non-Octa
5.5 AAOECO5005T
Octa
7.0 AAOECO5007T
Ø5.0
5.5 AAOECN5005T
Non-Octa Ø5.0
7.0 AAOECN5007T
Octa Non-Octa
5.5 AAOECO6005T
Octa
7.0 AAOECO6007T
Ø6.0
5.5 AAOECN6005T
Non-Octa
7.0 AAOECN6007T Ø6.0

AnyRidge – 091
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Octa Abutment

Gold Cylinder
Profile
Diameter Type Ref.C Octa Non-Octa

- Cylinder Screw(IRCS200) included. Octa AANGCO4000T


Ø4.0
• For customizing abutment for screw retained Non-Octa AANGCN4000T 12
multi-unit restoration.
• Available in both octa(red) and non-octa(white). Octa IOGO100T
• Melting point of gold alloy : 1400 - 1450℃ Ø5.0
• Threaded sleeves allow better retention of resin or wax. Non-Octa IOGN100T
• Available in three diameters (Ø4.0, 5.0, 6.0). Ø4.0
Octa AANGCO6000T
• Recommend torque : 30Ncm
Ø6.0 Octa Non-Octa Octa Non-Octa
Non-Octa AANGCN6000T

Ø5.0 Ø6.0

CCM Cylinder
Octa Non-Octa
Profile
Diameter Type Ref.C
- Cylinder Screw(IRCS200) included.
Octa AANCCO4000T
• Threaded sleeves allow a better retention of Ø4.0 12
Non-Octa AANCCN4000T
resin or wax.
• Available in both octa (pink) and non-octa Octa AANCCO5000T
(yellow) and three diameters (Ø4.0, 5.0, 6.0). Ø5.0
• Recommend torque : 35Ncm Non-Octa AANCCN5000T
Ø4.0
• Can be casted with non-precious alloys
(Ni-Cr, Cr-Co alloys). Octa AANCCO6000T
Ø6.0 Octa Non-Octa Octa Non-Octa
Non-Octa AANCCN6000T

Ø5.0 Ø6.0

Plastic Cylinder
Profile
Diameter Type Ref.C
Octa Non-Octa

- Cylinder Screw(IRCS200) included. Octa AAOTCO4010T


Ø4.0
• Economical option. Non-Octa AAOTCN4010T 10
• Used for customizing abutment a screw retained
multi-unit restorations. Octa IOPH100T
Ø5.0
• Available in both octa (red) and non-octa (white)
Non-Octa IOPN100T Ø4.0
• Threaded sleeves allow a better retention of resin
Octa AAOTCO6010T Octa Non-Octa Octa Non-Octa
or wax.
• Recommend torque : 25Ncm Ø6.0
Non-Octa AAOTCN6010T

Ø5.0 Ø6.0

092­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Ⅱ. Abutment Level Prosthesis


3-1. Multi-unit Abutment & Components
(All-on-4) (N_Type)
For the design concept and rationale of the Multi-unit Abutment, Please refer to page.094

CCM Cylinder ZrGen Abutment

Temporary Cylinder

Scan Abutment Impression Coping Lab Analog

Multi-unit Abutment Multi-unit Angled Multi-unit Angled [Regular] [Wide]


[Straight] Abutment [17°] Abutment [30°] Healing Cap
(Refer to Page.098)

AnyRidge – 093
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ Multi-unit Abutment TM

Multi-unit Abutment
Design Concept
MegaGen Implant develops the special abutment named as Multi-unit Abutment, which can be the solution for the edentulous patients.
With 4 fixtures placed into patient’s ridge and a hybrid denture on those four fixtures, a patient can recover his or her dental condition
almost completely. In most cases, Multi-unit Abutments work in a set of 2 x straight type abutment for anterior position and 2 x angled type
abutment on posterior position.

Features

You could see how Multi-unit Abutment functions and what benefits you could get from Multi-unit Abutment are as the followings:

• 2 fixtures which are slantly implanted on posterior position are osseointegrated with cancellous bone. These fixtures function as dispersing
vertical load on alveolar bone.
• Multi-unit Abutment is only 4 fixtures + 4 abutments. It means that dental surgeon has enough places for surgery. Therefore, it will be easy
to find and place 4 fixtures into ridge where abundant cancellous bone exists.
• A doctor can use graft bone material if a patient dosen’t have enough alveolar bone. However, the slantly placed fixtures can overcome the
patient’s insufficient bone by getting good holding strength with this angulation.

• In addition, these angulated fixtures can avoid touching important anatomies, such as mandibular nerve and maxillary sinus.

• All on 4 technique is also possible to do guided surgery using R2GATE Guide with a diagnosis from R2GATE.

094­
▸▸ Multi-unit Abutment N Type

The solution for the edentulous patients

Various Angles
Straight, 17°, 30°

Various Cuffs
Internal
Straight :1.5, 2.5, 3.5, 4.5mm
17°: 2.5, 3.5mm
30°: 3.5, 4.5mm Prosthetics compatibility
Nobel Abutment
External
Straight :1, 2, 3, 4, 5mm
17°: 2, 3, 4mm
Post Diameter Ø4
30°: 4, 5mm
Post Angle
44˚

Post Height
2.2mm

Connection
AnyRidge Internal
AnyOne Internal, External

Post Platform
Diameter Ø4.8

Compatibility with others’


Multi-unit level prosthetic
Benefit Available implant System components

1. Easy and economical treatment solution - AnyRidge Internal ✓ Post Height


for compromised edentulous cases. - AnyOne Internal
2. Expensive and time consuming bone - AnyOne External ✓ Post Diameter
graft may not be necessary. ✓ Post Angle
3. Multiple angles (0˚, 17˚, 30˚) support
✓ Abutment Angle
different implant insertion paths.
4. Universally compatible with other Multi- ✓ Cuff Height
unit systems.

AnyRidge – 095
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Multi-unit Abutment

Multi-unit Abutment Cuff Height (mm) Type Ref.C

[AR] - Straight 1.5 MUAARN0015C C.H


- MUA Straight Carrier (MUASC) included
2.5 1-piece MUAARN0025C
• Recommend torque : 35Ncm
3.5 (M1.8) MUAARN0035C

4.5 MUAARN0045C
Ø4.8

Multi-unit Angled Abutment Cuff Height (mm) Type Ref.C


17°
[AR] - 17° 2.5 MUAARH1725LC
- MUA Screw (MUAARS) included 3.5 Hex MUAARH1735LC C.H
- MUA Angled Carrier (MUAAC) included
4.5 MUAARH1745LC
• Recommend torque : 25Ncm
2.5 MUAARN1725LC

3.5 Non-Hex MUAARN1735LC

4.5 MUAARN1745LC

Multi-unit Angled Abutment Cuff Height (mm) Type Ref.C 30°

[AR] - 30° 3.5 MUAARH3035LC


Hex
- MUA Screw (MUAARS) included 4.5 MUAARH3045LC C.H
- MUA Angled Carrier (MUAAC) included
3.5 MUAARN3035LC
• Recommend torque : 25Ncm Non-Hex
4.5 MUAARN3045LC

096­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Multi-unit Abutment (Continued)

Impression coping Connection Ref.C

(Pick-up) Non-Hex MUAICT 10.7


15

- Guide pin (MUAGP) included


2
• Use to take an impression at the abutment level.
• Open tray method. Ø4.8

2.2 44°

Lab Analog Head form Ref.C 11.2

• Use to duplicate the Multi-unit abutment in the working Multi-unit Abutment(Nobel) MUALA
model.
• Available to use as a RP Analog for 3D printed working Ø4.8
model.

Ø3.3

Temporary Cylinder Connection Ref.C


12
- Cylinder Screw (MUAS) included Non-Hex MUATCL
3.4
• Use for fabricating acrylic provisional restoration.
• Grooves on the post cylinder allow storing resin adhension.
• Back-up screw is included. Ø4.8
M1.4
• Recommend torque : 15Ncm

Ø3.3

CCM Cylinder Connection Ref.C 15

- Cylinder Screw (MUAS) 2EA included Non-Hex MUACCML


• Use for fabricating screw retained prostheses with 3.4
metal reinforced or bar structured overdentures.
• Available to cast with non-precious dental alloys
Ø4.8
(Ni-Cr, Cr-Co alloys) M1.4
• Melting temperature of CCM base: 1380 - 1420℃
• Back-up screw is included.
• Recommend torque : 15Ncm

AnyRidge – 097
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Multi-unit Abutment

Healing Cap Type Ref.C


Regular Wide

- Cylinder Screw (MUAS) 2ea included Regular MUAHCL 1.5 3.4


• The size of healing cap can be selected 4.2 1.7
Wide MUAHCWL
depending on soft tissue volume or type
of restorations. Ø4.9 Ø4.9 M1.4
Ø6.8

Healing Cap Set reference code


Order code : Add “P” after the existing reference code
Ex) MUAHCL → MUAHCP

Try-in Abutment Angle Cuff Marking Ref.C


• Cuff height is indicated with laser markings
• Straight17˚, 30˚ Straight 1.5 / 2.5 / 3.5 / 4.5 MUTIAAR00C
• Non-hex type
17˚ 2.5 / 3.5 / 4.5 MUTIAAR17C 4.5 3.5 2.5
1.5
30˚ 3.5 / 4.5 MUTIAAR30C

Straight 17˚ 30˚

Try-in Abutment Set reference code


Order code : MUTIAAR00P

※ Available Systems : AnyRidge, AnyOne Internal,


AnyOne External
※ Kit contains Straight, 17˚ and 30˚ type of Try-in
Abutments (1 each)

098­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Multi-unit Driver Hex Length Ref.C


• Use to torque straight type Multi-unit Abutments. 20
• Use with a torque wrench (ref code: MTW300A) 2.0 10 MUD10
10

Ø4.4

Right Angle Driver Hex Length Ref.C 24


• Use to torque straight type Multi-unit Abutments. 2.0 10 MURAD10
• Use with latch-type handpiece. 10
• Use with Meg-TORQ (ref code: MEG_TORQ)

Ø4.4

Hand Driver Hex Length Ref.C 29


• Use for abutment screw with 1.2 hex hole. 20
• Use up to 15˚ divergent. 1.2 20 MUHD1220
• It should use under 30Ncm torque.

Hex1.2

Removal Driver Hex Length Ref.C 29


• Use for abutment screw with 1.2 hex hole. 20
• Use up to 15˚ divergent. 1.2 20 MUARD20 M2.0
• Exclusively for AnyRidge system.
• It should use under 30Ncm torque.

Hex1.2

AnyRidge – 099
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ S
 crew & Abutment Tightening Torque Guide
• Abutment Screw (M1.8 & M2.0) : 25Ncm
• Cylinder Screw (M1.4) : 15Ncm
• Straight Abutment (M1.8 &M2.0) : 35Ncm

Instruction for removing abutment screw from Multi-unit abutment


[Exclusively for AnyRidge system]

1. Completely unscrew abut- 2. Pull the Hand Driver up straight 3. Slightly rotate the screw to the 4. Remove abutment with the
ment screw by rotating it until it is visible through abut- main access hole. Otherwise Removal Driver (ref code:
counterclock wise (approxi- ment crew hole. Shaking left the screw could fall back into the MUARD20) by rotating it
mately 4 rotations are required). and right may be required if screw hole due to distur clockwise.
It should sue with a Hand the screw becomes stuck bance of abutment structure.
Driver (ref code: MUHD1220) inside of the abutment hole.

Driver Tightening Torque Guide

1. Multi-unit Abutment 2. Multi-unit Hand Driver


Remover Driver

Fracture
Location Fracture
Location
< 30Ncm < 30Ncm

• Excessive torque more than 30Ncm may cause fracturing of the driver.
• Straight type Multi-unit abutment needs to use the Multi-unit Driver that is provided in the starting package. (ref code: MUD10)
• Strongly recommended to pick up the abutment screw by pressing the Hand Driver to remove the abutment screw from the
Multi-unit abutment.

100­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Multi-unit Abutment

70
Surgical Guide Angle Marking Length Ref.C
7 30˚
(mm)
• The distance between the lines is 7mm
10
• Put center pin after initial drilling at the centric 30º 7 MUSG70
of arch. (Refer to the surgical protocol on
page.104) 14

Ø2.0

▸▸ How to use Surgical Guide


※ As Canine and second premolar are most commonly used, the surgical guide has thicker lines for easier identification.
※ The surgical guide is able to use for first molar depending on surgical plan.

Bend to use

Instruction for use

5
6

2 3 4

Label
Product

[Packing]

AnyRidge – 101
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ Multi-unit Abutment Set Contents


Multi-unit Abutment Healing cap type Set reference code
Order code : Add “HP” after the existing reference code
Ex) MUAARH1725LC → MUAARH1725 HP

Multi-unit Abutment CCM type Set reference code


Order code : Add “P” after the existing reference code
Ex) MUAARH1725LC → MUAARH1725 P

Straight Angle 17˚ Angle 30˚

AnyRidge

Cuff Cuff Cuff


1.5mm 2.5mm 3.5mm
2.5mm 3.5mm 4.5mm
3.5mm 4.5mm
4.5mm

Impression
Coping

Lab Analog

Temporary
Cylinder

Healing CCM
Cap OR Cylinder
(Regular)

102­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ Starting Package Contents


Type Ref.C

Hex SKARHN3000H
Healing Cap
Non Hex SKARNN3000H

CCM Hex SKARHN3000


Abutment Non Hex SKARNN3000

Straight 8set Angle 17 6set Angle 30 4set Surgical Instrument


(2set x 4kind of cuff) (2set x 3kind of cuff) (2set x 2kind of cuff)

Multi-unit Right Angle Hand Removal


Driver Driver Driver Driver

Healing Cap 2set Try-in Abutment 1set


(Straight, 17∘, 30∘each 1ea)

Regular

Multi-unit Abutment
OR
with *carrier
* MUA carrier is used to pick- Wide
up an abutment to the
patient’s mouth, and check
its insertion angle.

Surgical Guide 2ea


Healing Cap (Regular)
or CCM Cylinder
Temporary Cylinder
Lap Analog
Impression Coping

AnyRidge – 103
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ S
 urgical Protocol
Conventional Surgery

1. Initial drilling 2. Guide Bending & Position


For placement of center Bend according to the
pin after initial drilling in the patient’s arch.
centric of the arch. The drill-
ing hole should be in lingual
area of the arch to ensure
the best result.

7. Tightening the Abutment


Abutment Screw tighten- Straight Abutment tight-
ing Torque : 25Ncm ening Torque : 35Ncm
After connecting Abutment After removing Carrier,
Screw, remove Carrier from connect Abutment to the
Abutment. For 17˚ abut- Fixture using Right Angle
ment, you need to tighten Driver or MUA Driver.
it by tilting Driver about 5˚.
Connect Abutment and
check the path using Carrier.

8. Impression 9. Healing Cap


Take an impression with an Cylinder Screw tighten-
individual tray. (Open tray ing Torque : 15Ncm
method is strongly recom- Place Healing Cap on top
mended to avoid any error of Multi-unit abutment, and
in the future.) connect Cylinder Screw
with the Hand Driver.

104­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

3. Drilling 4. The fixture is implanted


Drill according to the Place implant fixtures ac-
surgical plan. cording to the surgical
plan and do not exceed
torque value (60Ncm)

6. Abutment Selection 5. Try-in Abutment


Select the appropriate set Using the laser marking on
after checking the angu- the Try-in abutment, select
lation and cuff height that the appropriate cuff height
were measured with the and angulation of Multi-unit
Try-in abutment. Con- abutments.
nect the abutment onto
the fixture and check the
angulation and the cuff
height.

10. Suture

AnyRidge – 105
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ S
 urgical Protocol
Guided Surgery

1. Guide 2. Narrow Crest Drill


Place a R2GATE Guide. For the cases with narrow
ridge or placing a fixture
slanted on the lingual side,
you can flatten the surface
and drill stably without
slipping

8. Setting Temporary and Denture 7. Connect Temporary Cylinder in the front


Reline the temporary denture Connect the Temporary Cylinders
with resin to fill the space in the front. Make sure that
around the Temporary holes in the denture are free
Cylinder. from any contact with the
Temporary Cylinder. Adjust
the holes until there is no
contact between the denture
and the Temporary Cylinder.
*If the Temporary Cylinder is
fixed using Guide Pin, resin flow
into access hole will be prevented.

9. Connect Temporary 10. Setting Temporary and Denture


Cylinder in the back All temporary cylinders are
picked up in the denture with
Connect rest of the
resin.
Temporary Cylinders in
the back, make sure that
the holes in the denture
are free from any contact
with the Temporary Cylinder.
Adjust the holes until there
is no contact between the
denture and the Tempo-
rary Cylinder.

106­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

3. Drilling 4. Fixture Placement


Drill according to the drilling sequence.

6. Abutment Selection 5. Try-in Abutment


Select the appropriate set Using the laser marking
after checking the angulation on the Try-in abutment,
and cuff height that were select the appropriate
measured with the Try-in cuff height and angulation
abutment. Connect the of Multi-unit abutments.
abutment onto the fixture
and check the angulation
and the cuff height.

11. Temporary Fixation 12. Tighten the Denture 13. Finish


Remove Denture and fill up the bottom and Cylinder Screw tightening Torque : 15Ncm Close Hole using EZ Seal and finalize
other non-resin filled parts with resin and Set Denture onto Multi-unit Abutment and the surgery.
completely fix Temporary Cylinder. tighten cylinder

AnyRidge – 107
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

▸▸ Multi-unit Abutment S Type


The solution for the edentulous patients
For the design concept and variable of the Multi-unit Abutment, Please refer to page.094

Various Angles
Straight, 17°, 29°

Various Cuffs Prosthetics compatibillity


3i Multi-unit AbutmentRegular Abutment
Straight Type : 2, 3, 4, 5mm
(MegaGen)
Angled Type : 1, 2, 3, 4mm

Various Cuffs
- Straight Type : 2, 3, 4, 5mm
- Angled Type : 1, 2, 3, 4mm

Connection Post Diameter


- AnyRidge Internal Ø4.0
- AnyOne Internal
Post Angle
30˚

Post Height
3.9mm

Benefit Available implant System Post Platform


Diameter Ø5.0

1. R
 etrievability means that doctor can change - AnyRidge Internal
or retrieve the final prosthetics easily. - AnyOne Internal

2. Two types of angulation : 17˚, 29˚. It means


that doctor has various options to angle.

3.Various cuff heights (1~5mm) : Doctor


can have flexiblily on the depth of fixture
placement.

4. M
 egaGen’s Multi-unit Abutment is perfectly
compatible with the prosthetic compo-
nents of Multi-unit Abutment of 3i im-
plant, and Regular Abutment of Mega-
Gen’s Exfeel External system.

108­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Ⅱ. Abutment Level Prosthesis


3-2. Multi-unit Abutment & Components
(All-on-4) (S-Type)
For the design concept and rationale of the Multi-unit Abutment, Please refer to page.094

EZ Post Cylinder Gold Cylinder CCM Cylinder Multi-unit

Temporary Cylinder

Lab Analog

Impression Coping Impression Coping


[Transfer] [Pick-Up]

Multi-unit Abutment Multi-unit Angled Abutment Multi-unit Angled Abutment Healing Cap
[Straight] [17°] [29°] (Refer to Page.111)

AnyRidge – 109
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Multi-unit Abutment

Multi-unit Abutment Cuff Height (mm) Type Ref.C

(Straight) 2.0 AANMUH5020T


C.H
3.0 AANMUH5030T
- Multi-unit Abutment Screw(AANMUS20) Hex
included. 4.0 AANMUH5040T Hex
Ø5.0
• Use with Multi-unit Driver.
- TCMMUDS20 (short) 5.0 AANMUH5050T
- TCMMUDL20 (long) 2.0 AANMUN5020T
• Recommend torque : 35Ncm
3.0 AANMUN5030T Non-Hex
Non-Hex
4.0 AANMUN5040T

5.0 AANMUN5050T

Multi-unit Cuff Height (mm) Type Ref.C

Angled Abutment (17°) 1.0 AANMUH50117L

2.0 AANMUH50217L C.H


- Multi Post Screw(MUMSF/MUMST)
Hex
included. 3.0 AANMUH50317L Hex
• Recommend torque : 35Ncm Ø5.0
4.0 AANMUH50417L

1.0 AANMUN50117L

2.0 AANMUN50217L Non-Hex


Non-Hex
3.0 AANMUN50317L

4.0 AANMUN50417L

Multi-unit Cuff Height (mm) Type Ref.C

Angled Abutment (29°) 1.0 AANMUH50129L

- Multi Post Screw(MUMSF/MUMST) 2.0 AANMUH50229L


Hex C.H
included. 3.0 AANMUH50329L Hex
• Recommend torque : 35Ncm
4.0 AANMUH50429L Ø5.0

1.0 AANMUN50129L

2.0 AANMUN50229L
Non-Hex
Non-Hex
3.0 AANMUN50329L

4.0 AANMUN50429L

110­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Multi-unit Abutment (Continued)

Lab Analog Profile Diameter Ref.C

Ø4.8 RELA300

4.8

Hex Non-Hex

Temporary Cylinder
Profile
Diameter Type Ref.C

- Cylinder Screw (TASH140) included Hex ETH100T


Ø4.8
• Recommend torque : 15Ncm Non-Hex ETN100T

4.8

EZ Post Cylinder
Hex Non-Hex
Profile
Diameter Type Ref.C

- Cylinder Screw (TASH140) included Hex RCA900T


• Recommend torque : 15Ncm Ø5.0
Non-Hex RCA800T
5.0

Healing Cap Profile Diameter Ref.C

Ø5.0 REC600
5.0

Non-Hex

Impression Coping Profile Diameter Ref.C

(Transfer) Ø4.8 RITE480

4.8

Impression Coping Height (mm) Type Ref.C


Hex Non-Hex

(Pick-Up) Hex RIEH480T


9.4
9.4
- Guide Pin (RICG150) included Non-Hex RIEN480T

AnyRidge – 111
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Multi-unit Abutment

Gold Cylinder
Profile
Diameter Sleeve Color Ref.C
Hex Non-Hex

- Cylinder Screw (TASH140) included Red REGC200T


Ø5.0
• Useful to make a customized abutment in difficult
White REGC100T
situations.
• Precious and non-precious alloys.
• Melting point of gold alloy : 1400 - 1450℃
• Threaded sleeves for convenient Resin / Wax-up. 5.0
• Recommend torque : 15Ncm

CCM Cylinder
Profile
Diameter Sleeve Color Ref.C Hex Non-Hex

- Cylinder Screw (TASH140) included Pink RCA5013HT


Ø4.8
• Useful to make a customized abutment in difficult
Yellow RCA5013NT
situations.
• Can be casted with non-precious alloys
(Ni-Cr, Cr-Co alloys).
• Non-precious melting temperature : Depends on 4.8
Manufacturer
• Threaded sleeves for convenient Resin / Wax-up.
• Melting temperature of CCM : 1380 - 1420℃
• Recommend torque : 15Ncm

Hex Non-Hex

Plastic Cylinder
Profile
Diameter Sleeve Color Ref.C

- Cylinder Screw (TASH140) included Red RPEH100T


• Recommend torque : 15Ncm Ø5.2
White RPEN100T

5.2

112­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Ⅱ. Abutment Level Prosthesis


4. Flat Abutment & Components
: The main advantage of this Flat Abutment is the freedom on angulation.
Flat Abutment can cover any angulation problems.
: Only for multiple (Cannot be used for single implant)
: Only with screw-retained prosthetics.

Flat EZ Post Cylinder Flat Gold Cylinder Flat CCM Cylinder Flat Plastic Cylinder

Flat Temporary Cylinder

Flat Lab Analog

Flat Impression Coping Flat Impression Coping


(Transfer) (Pick-Up)

Flat Healing Abutment Flat Cover Screw Flat Abutment

AnyRidge – 113
®
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

➲ Components for Flat Abutment (Continued)

Flat Abutment Profile Diameter Cuff Height


(mm) Ref.C

- Use Hand Driver (1.6 Hex) 1 AANFAL3510


• Recommend torque : 25Ncm
2 AANFAL3520 C.H

Ø3.5 3 AANFAL3530

4 AANFAL3540 3.5

5 AANFAL3550

Flat Cover Screw Profile Diameter Ref.C 3.5

• Recommend torque : by hand (5 - 8Ncm) 1.5


Ø3.5 FCS3510

Flat Healing Abutment Height(mm) Ref.C

• Recommend torque : by hand (5 - 8Ncm) 2 FHA402


H
3 FHA403

4 FHA404

Flat Impression Coping Profile


Diameter Height (mm) Ref.C
9.5
(Transfer) Ø3.5 9.5 FIT4012T
- Guide Pin (FGPT) included.
3.5
• Should be tightened with Impression Driver
(Page. 256)
• Special impression coping screw which can be
used with a 1.2mm hex driver is available on
request.

Flat Impression Coping Profile


Diameter Height (mm) Ref.C
(Pick-Up)
- Guide pin (FGPP15) included. Ø3.5 12 FIP4012T 12

3.5

Flat Lab Analog Profile


Diameter Height (mm) Ref.C

Ø3.5 12 FLA3512 12

3.5

114­
Abutment & Prosthetic Options » Ⅱ. Abutment Level Prosthesis

Flat Temporary Cylinder Profile Diameter Ref.C

- Flat Cylinder Screw (FAS) included. Ø4.0 FTC4012T


• Recommend torque : 15Ncm

4.0

Flat EZ Post Cylinder Height (mm) Ref.C


- Flat Cylinder Screw (FAS) included.
5.5 FEC4005T H
• Recommend torque : 25Ncm
7.0 FEC4007T

Flat Gold Cylinder Profile Diameter Ref.C

- Flat Cylinder Screw (FAS) included. Ø3.8 FGC4012T


• Useful to make a customized abutment in difficult
situations.
• Precious and non-precious alloys.
• Melting point of gold alloy : 1400 - 1450℃
3.8
• Threaded sleeves for convenient Resin / Wax-up.
• Recommend torque : 25Ncm

Flat CCM Cylinder Profile Diameter Ref.C

- Flat Cylinder Screw (FAS) included.


Ø3.8 FCC4012T
• Useful to make a customized abutment in difficult
situations.
• Can be casted with non-precious alloys (Ni-Cr,
Cr-Co alloys).
• Non-precious melting temperature : Depend on
Manufacturer 3.8
• Threaded sleeves for convenient Resin / Wax-up.
• Melting temperature of CCM : 1380 - 1420℃
• Recommend torque : 25Ncm

Flat Plastic Cylinder Profile Diameter Ref.C


- Flat Cylinder Screw (FAS) included.
Ø4.0 FPC4012T
• Recommend torque : 25Ncm

4.0

AnyRidge – 115
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

NEW
PRODUCT NEW PRODUCT

Ⅲ. Overdenture Prosthesis
1. MegaGen Overdenture System

Meg-Loc
Compatible with products L and K, excellent functionality, & incomparable price!

Combination of Titanium housing and Pekkton (reinforced plastic) creates low


water solubility and higher wear resistance and durability than other existing
products.
Retention insert offers wide range of retention forces (600gf, 1200gf, 1800gf) to
suit each patient, resulting in high level of satisfaction for both patient and dentist.
Strong physical properties of Pekkton and insert gap increase elasticity, so that
insert does not tear or break unlike conventional nylon products, thereby ensuring
strong retention and longer life.

Meg-Ball
Smallest housing, retentive ring with longer life!
Even when the implant angle is not parallel, a stable denture can still be produced!

Compatible with other products with Ø2.25 head size, minimized patient incon-
venience due to small-size housing, simpler to arrange artificial teeth as space
occupied by denture is reduced, and easier to maintain than other systems.
Retentive ring has a high elasticity, abrasion resistance, and durability, thereby
doubling the length of life when compared to a silicone O-ring and guaranteeing a
longer life than NBR products.
Positioner (0/5/10/15 degrees) maintains parallel housing direction, even with dis-
torted implant placement angle, ensuring denture stability.

Meg-Magnet
Designed to maintain stable and sufficient magnetic force!
Completely blocks bursts and corrosion resistant!

Structure is connected with abutment using magnetic force, which is feasible


even with insufficient bone volume or poor bone quality
Easy to attach and detach, and minimal inflammation.
Magnet of Ø4.5 & Ø5.0 is compatible with other products, and laser marking on
upper part makes it easy to distinguish between up and down.
Sufficient magnetic force (450gf, 650gf) ensures stable retention
Laser sealing blocks any bursting phenomenon.
TiN coating provides corrosion resistance.
Positioner (small & regular) prevents magnet from slipping in the mouth and stops
any flow of impression materials under the abutment.

Meg-Rhein
Can compensate for tilted implant placement angle up to 50 °.

Combined head and housing structure is smallest on the market.

Retentive cap is based on Italian technology and has uniform physical properties.
Various retention forces (600gf, 1200gf, 1800gf, 2700gf) classified by color can
be selected according to each patient.

Dynamic housing with double structure enables tilting to 25 ° angle, allowing


stable denture even when with distorted implant placement angle.

116­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

Ⅲ. Overdenture Prosthesis
2. Meg-Loc Abutment & Component

Meg-Loc Metal Housing set

Block-out Spacer

Meg-Loc Abutment

AnyRidge – 117
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

▸▸ Meg-Loc Overdenture System

Advantages

Easy compatibility Compatible with Product L and Product K (same specifications)

Better abrasion resistance Combination of Titanium housing and reinforced plastic (Pekkton) provides low water solubil-
and durability ity and high resistance, making it superior in abrasion resistance and durability compared to
existing products.
Water Sorption Test
Meg-Loc
Property Product L Unit
(Pekkton)

Water
8.7 93.5 µg/mm3
Sorption

Stronger retention Strong physical properties of Pekkton and gap in insert increase the elasticity, preventing the
and longer life insert from being torn or broken unlike existing nylon products, even when angle does not
match when attaching & removing denture.
100

100% 97%
Reduction rate(%)

50

Pekkton
Nylon
Low 10 10,000

Easy to use High resistance to plaque and easy cleaning


Easy replacement of retention insert

Tilting Angle
40º

Various Retentive
Caps of the Meg-Loc

Gray Extra-low Low Medium


(250-300g) (Yellow, 600g) (Red, 1200g) (Mint, 1800g)

118­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

➲ Meg-Loc Overdenture System

Meg-Loc Abutment Cuff Height (mm) Ref.C 1.5


C.H
-Angle compensation to one side 20 ° 0 MLAR00
Platform
(both sides 40 °) level
- Gently rounded shape
1.0 MLAR01
- Compatible with 1.2 Hex Driver 2.0 MLAR02
• Recommend torque : 35Ncm
3.0 MLAR03

4.0 MLAR04

5.0 MLAR05

6.0 MLAR06

Meg-Loc Package Cuff Height (mm) Ref.C

- 1 Meg-Loc Abutment 0 MLAR00P

* Following package items are delivered with 1.0 MLAR01P


San DreMetto Korea packaging.
2.0 MLAR02P
- 1 Titanium Housing
3.0 MLAR03P
- 1 Block Out Spacer
- 4 Pekkton Retention Inserts 4.0 MLAR04P
(Gray-250~300gf(for lab), Yellow-600gf,
Red-1200gf, Mint-1800gf)
5.0 MLAR05P

6.0 MLAR06P

Multi Tool Ref.C

- Retention Insert Insertion & Removal Tool MLMT


120

AnyRidge – 119
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

Ⅲ. Overdenture Prosthesis
3. Meg-Ball Abutment & Component

Meg-Ball Metal Housing set

Housing Positioner
(0˚/5˚/10˚/15˚)

Meg-Ball Abutment

120­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

▸▸ Meg-Ball Overdenture System

Advantages

Ø2.25
Easy compatibility Ø2.25 head size for easy compatibility with other products

Ø5
Smallest Housing Small housing minimizes patient inconvenience, facilitates arrangement
of artificial teeth by reducing space occupied by denture, and is easier to
maintain than other systems.
Metal Housing

Double length of life High elasticity, abrasion resistance, and durability doubles the length
of life when compared with silicone O-ring and guarantees longer life
Retentive Ring than NBR products.

Stable denture even Positioner (0/5/10/15 degrees) maintains parallel housing direction even when angle of
when implant placement implant placement is distorted, ensuring denture stability
angle is distorted

0° 5° 10° 15°

Tilting Angle
30º

AnyRidge – 121
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

➲ Meg-Ball Overdenture System

Meg-Ball Abutment Cuff Height (mm) Ref.C

- Angle compensation to one side 15 ° 0 MBAR00 C.H


(both sides 30 °)
1.0 MBAR10 Platform
- Ø2.25 Ball shape level
• Recommend torque : 35Ncm 2.0 MBAR20

3.0 MBAR30

4.0 MBAR40

5.0 MBAR50

6.0 MBAR60

Meg-Ball Package Cuff Height (mm) Ref.C

- Composed of Meg-Ball Abutment/ 0 MBAR00P


Metal Housing Set/
Housing Positioner (0°,5°,10°,15°) 1.0 MBAR10P

2.0 MBAR20P

3.0 MBAR30P

4.0 MBAR40P

5.0 MBAR50P

6.0 MBAR60P

Metal Housing Retentive Ring

Meg-Ball Metal Housing Ref.C

Set MBHR
Ø5.0
- 1 Metal Housing
- 1 Retentive Ring

Retentive Ring Set Quantity Ref.C Retentive Ring

5 MBR5

10 MBR10

122­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

Ⅲ. Overdenture Prosthesis
4. Meg-Magnet Abutment & Component

Magnet
(Small / Regular)

Magnetic Positioner
(Small / Regular)

Magnetic Abutment

AnyRidge – 123
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

▸▸ Meg-Magnet Overdenture System

Advantages

Easy to apply for elderly Applicable with insufficient bone volume and poor bone quality
patients or disabled Easy to attach and detach
Unlikely to cause inflammation
patients

Designed for maximum Sufficient magnetic force (450gf, 650gf) to ensure stable retention
magnetic efficiency and Laser sealing blocks any bursting phenomenon
durability

Outstanding retention TiN coating provides corrosion resistance


- Blocks bursting Over 0.1mm thickness at contact with attachment to ensure wear resistance
- Corrosion resistant
- Abrasion resistant
0.3

Easy to distinguish Magnet of Ø4.5 & Ø5.0 is compatible with other products
between up and down via Laser marking on upper part makes it easy to distinguish between up and down
laser marking on upper
section

No slippage of magnet Positioner (small & regular) prevents magnet from slipping in mouth and stops any flow of
impression materials under the abutment
Small Regular

Ø4.5 Ø5.0
(450gf) (6 50gf)

Component of the
Meg-Magnet Ø4.5(Small) Ø5.0(Regular)

450gf 650gf

124­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

➲ Meg-Magnet Overdenture System

P.D
Meg-Magnet Abutment Profile
Diameter
Cuff Height
(mm) Ref.C
0.3
- Use to 1.2 Hex Driver 0 MMAR400 C.H
• Recommend torque : 35Ncm 1.0 MMAR410 Platform
level
2.0 MMAR420
Ø4.5
3.0 MMAR430

4.0 MMAR440

5.0 MMAR450

0 MMAR500

1.0 MMAR510

2.0 MMAR520
Ø5.0
3.0 MMAR530

4.0 MMAR540

5.0 MMAR550

Meg-Magnet Package Profile


Diameter
Cuff Height
(mm) Ref.C

- 1 Meg-Magnet Abutment 0 MMAR400P


- 1 Magnet (Ø4.5-450gf, Ø5.0-650gf)
1.0 MMAR410P
- 1 Magnetic Positioner
2.0 MMAR420P
Ø4.5
3.0 MMAR430P

4.0 MMAR440P

5.0 MMAR450P

0 MMAR500P

1.0 MMAR510P

2.0 MMAR520P
Ø5.0
3.0 MMAR530P

4.0 MMAR540P

5.0 MMAR550P

Small

Meg-Magnet Attachment Size Ref.C

Set Small MA402 Ø4.5


Regular MA502
Regular

Ø5.0

AnyRidge – 125
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

Ⅲ. Overdenture Prosthesis
5. Meg-Rhein Abutment & Components

Retentive Cap set Retentive Cap set


(Dynamic)

Lab Analog

Impression Coping

Meg-Rhein Abutment

126­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

➲ Meg-Rhein Overdenture System

8.8

Meg-Rhein Cuff Height (mm) Ref.C

Overdenture System 0 ADR00PA


C.H
(Dynamic) 1.0 ADR01PA

- 1 Meg-Rhein Abutment 2.0 ADR02PA


- 1 Plastic Impression Coping 3.0 ADR03PA
- 1 Stainless Steel Housing (Dynamic) &
Black-Lab 4.0 ADR04PA
- 1 Protective Disk 5.0 ADR05PA
- 4 Retentive Caps
6.0 ADR06PA
(Yellow-0.6kgf, Pink-1.2kgf, White-1.8kgf,
White Cap & Violet Cap
Violet-2.7kgf)
Yellow Cap & Pink Cap
• Perfect compatibility with the Rhein83 from Italy.
• Recommend torque : 15Ncm. Protective Disk
Stainless Steel Housing (Dynamic)
& Black Cap
Meg-Rhein Abutment
with Plastic Impression Coping

8.8

Meg-Rhein Cuff Height (mm) Ref.C

Overdenture System 0 ADR00P


C.H
- 1 Meg-Rhein Abutment 1.0 ADR01P
- 1 Plastic Impression Coping
2.0 ADR02P
- 1 Stainless Steel Housing
- 1 Protective Disk 3.0 ADR03P
- 5 Retentive Caps 4.0 ADR04P
(Black-Lab, Yellow-0.6kgf, Pink-1.2kgf,
White-1.8kgf, Violet-2.7kgf) 5.0 ADR05P

• Perfect compatibility with the Rhein83 from Italy. 6.0 ADR06P


• Recommend torque : 15Ncm. White Cap & Violet Cap
Yellow Cap & Pink Cap
Protective Disk
Stainless Steel Housing & Black Cap
Meg-Rhein Abutment
with Plastic Impression Coping

AnyRidge – 127
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

▸▸ Overdenture System

Advantages

Normal Dynamic

4.8mm
4.4mm
Small & Easy-to-Use
2.2mm
Housing System 2.1mm

Tilting Angle 50º


30º

Various Retentive Caps


of the Meg-Rhein

Yellow Pink White Violet


(0.6kgf) (1.2kgf) (1.8kgf) (2.7kgf)

Before After (1,000cycles)


Low Reduction Rate & 100 3
Retentive force (kgf)

Uniform Variance of 80
27%
38% 37%
2
Retentive Force 73
49%
R2=0.85
60 63
62
1
51
40
0
1,000 Cycles
20
R (Coefficient of determination) becomes more reliable
2

0 when it is close to “1”.


Meg-Rhein Product K Product L Product P

128­
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

➲ Components for Meg-Rhein Abutment

Stainless Steel Housing Ref.C

• 5ea/pack MHP

Stainless Steel Housing Ref.C

(Dynamic) THP

• 5ea/pack

Retentive Caps (White) Ref.C

• White cap(1.8kg) - For refill (5ea/pack). RCWP


• Can be used for more retentive force following pink
cap(1.2kgf).

Retentive Caps (Violet) Ref.C

• Violet cap(2.7kg) - For refill (5ea/pack). RCVP


• Can be used for more retentive force following
white cap(1.8kgf).

Retentive Caps (Pink) Ref.C

• Pink cap(1.2kgf) - For refill (5ea/pack). RCPP

Retentive Caps (Yellow) Ref.C

• Yellow cap(0.6kgf) - For refill (5ea/pack). RCYP

Retentive Caps (Black) Ref.C

• For laboratory RCBP

AnyRidge – 129
®
Abutment & Prosthetic Options » Ⅲ. Overdenture Level Prosthesis

Stainless Impression Ref.C


5.5

Coping (Pick-Up) 044CAIN

• 2ea/pack.
• Italy - Rhein 83 products.
• For accurate (pick-up type) impression.
• Metal with groove design to prevent from swaying.

Lab Analog Ref.C

PLA

Retentive Cap Ref.C

Removal Tool 091EC


90
• Retentive Cap removal tool.

Retentive Cap Ref.C

Insertion Tool 085IAC


83
• Retentive Cap insertion tool.

40

130­
Why will AnyRidge
work in any ridge?
Wider fixture in
Narrow upper a narrow crest
diameter To maximize long term survival
of implants.
To maximize preservation
by minimizing stress
on the cortical bone.

· For faster, stronger


osseointegration.

Knife-Threads
· New surface technology
+
incorporating Ca2
ions on the SLA treated
surface. · For smooth insertion and
· 100% elimination of stronger primary stability.
any remaining acid from · No cuting edge for
the conventional SLA minimum invasion.
process. · Ideal for soft bone cases.

Tapered body
Excellent for simple installation
Narrow apical
and Immediate loading.
diameter
For easier fixture insertion into
a narrow ridge split incision
Case1 Case2

final restoration

AnyRidge – 131
®
Clinical Cases

AnyRidge Clinical Case


➲ Clinical Case 1
- Courtesy of Dr. Kwang-Bum Park

AnyRidge implant has excellent surface treatment which can be osseointegrated


at this extreme case of bone defect.

Fig 1. This patient was 56 years old male


patient and had a chief complaint of chew-
ing difficulty on the left first mandibular mo-
lar due to periodontitis. On the panoramic
radiograph, the tooth was floated with
complete bone loss to the apex, and there
was not enough bone to get initial stability
for implant placement at the apex above
mandibular nerve. So I decided to extract
the tooth and wait for 4 months for regen-
eration of the socket.

Fig 2. The patient came back to my office


after 4 months. Healing appeared good
enough clinically, but the panoramic view
still showed large socket defect. In many
cases like this, we can expect some amount
of bone filled in the socket which can allow Fig 1

minimal initial stability for implant placement.

Fig 3. When the flap was opened, I was very


embarrassed that bone regeneration did
not occur in the socket. None of remaining
bone could be used for implant fixation.

Fig 4. A widest AnyRidge implant 8.0mm


was placed on the mesial wall of extrac-
tion socket, but there was no initial stabil-
ity. This trial was quite heroic treatment, Fig 2
but there was no other option except this
because he spent many hours for this
surgery.

Fig 5. The mixture of Allograft (Mega-Oss)


and Synthetic bone (Bone Plus) was
placed into the remaining socket defect
and a collagen membrane was covered. Fig 3
Then primary closure was made with inci-
sion releasement on the periosteum.

Fig 4

Fig 5

132­
Clinical Cases

Fig 6. On the panoramic view after surgery,


we could find that none of the fixture was
engaged with remaining bone, so it had
more than 1.6mm gap from the tip to the
depth of knife threads. I worried about the
bone filling and success of the osseointe-
gration on this fixture.

Fig 7. However, I was surprised with the


hard cortical bone regeneration over the
cover screw when I did the second stage
surgery with the Biolaser.

Fig 8. On the intraoral radiograph taken


several weeks after second surgery, we
could see the fully regenerated bone into
the bottom of thread depth. Fig 6

Fig 9. The patient came back to our office


to get one more implant on the maxillary
upper molar after 2 years from the first im-
plant surgery. The regenerated bone was
matured and showed very stable crestal
bone on the intraoral radiograph.

Fig 7

Fig 8

Fig 9

AnyRidge – 133
®
Clinical Cases

➲ Clinical Case 2
- Courtesy of Dr. Kwang-Bum Park

Advantage of fuse abutment with AnyRidge implant for immediate loading


in upper fully edentulous case

Fig 1. An 80-year-old female patient pre-


sented with discomfort related to her
upper teeth. About 10 years previously
she underwent implant surgery in the
mandible and received temporary teeth
immediately as the bone density was suf-
ficient for immediate loading. The patient
requested a treatment plan for the upper
arch that would give her immediate teeth.

Fig 2. Clinical photos before surgery.


The patient had no discomfort or
complaints related to her mandibular
implants. Plus her hygiene control
was very good for maintaining healthy Fig 1

peri-implant tissue.

Fig 3. All the remaining teeth were


extracted. As shown, some teeth
had severe periodontitis and some
had decay at the cervix of the tooth.
Drilling up to 2.9 mm was conducted Fig 2

at each implant site and eight 3.5×15mm


implant fixtures were placed using a mini-
mal flap design. All the fixtures showed
excellent initial fixation, and the imme-
diately-placed implants only had small
socket defects.
Fig 4

Fig 4. Eight fuse abutments were con-


nected and the flaps were sutured to
create a tight sealing against the fuse
abutments

Fig 5. The fuse abutments were prepared


Fig 3
using a high speed handpiece for a Fig 5

temporary bridge that was already made


before the implant surgery

Fig 6. Panoramic scan taken immediately


after surgery. The first premolar implant
showed some mis-fit between the crown
and the ratio.

Fig 7. Intraoral scans taken 2 months


after surgery. Shadows of the extraction
socket can still be seen, but regenerated
bone has started to fill the socket
defects. The fuse abutments are func-
tioning well without any problem.
An impression was taken for customized Fig 6
zirconia abutments

Fig 7

134­
Clinical Cases

Fig 8. Panoramic & intraoral scans taken


3 months after surgery. Zirconia
customized abutments were connected
to each fixture. The socket defects
are completely filled with regenerated
bone even in the case of immediate
loading on the immediately placed
Fig 8
implants.

Fig 9. Clinical photos of zirconia custom-


ized abutments and PMMA temporary
bridge made using CAD/CAM technique.
A zirconia abutment is excellent for both
esthetics and hygiene maintenance. It
has less than 1/10 bacterial accumulation
on the surface compared with metals
Fig 9
including titanium. PMMA provisional
bridge is stronger than tooth resin, espe-
cially at the margin, so much beneficial
for functional and occlusal tests.

Fig 10. A full zirconia one-piece bridge


was made and delivered. The patient was
Fig 10 very satisfied with the results, and thank-
ful that she was provided with ‘teeth’
from the beginning to the end.

Fig 11. Panoramic scan of final restora-


tions on day of delivery

Fig 12. Panoramic scans at 7 years


follow-up

Fig 11

Fig 12

AnyRidge – 135
®
Clinical Cases

➲ Clinical Case 3
- Courtesy of Dr. Soheil Bechara

Simultanious sinus lift and implant placement

Fig 1. The patient presented with huge


bony defects around residual roots in the
upper jaw. The treatment plan was to
perform immediate implant placement
and extract all decayed roots during one
surgical session, as the patient had only
one week to stay in the country. Fig 1

Fig 2. Lateral window sinus lifting was


performed on the right side with simul-
taneous implant placement in tooth
area 17. In area 14 we can observe a
huge bony defect which was thoroughly
debrided until the margins of healthy
bone. The Osteotomy was prepared with
Fig 2
a 2mm final drill to place a 3.5x15mm
Anyridge implant.

Fig 3. 3.5x15mm Anyridge implant was


placed having only 2mm contact with
the bone in the coronal part achieving 25
Ncm of initial torque.

Fig 4. The bony defect was filled with a Fig 2 Fig 3


Xenograft and covered with a collagen
membrane. Although the defect is huge
but it is still considered as an intra-bony
defect with a good potential of bone
regeneration.

Fig 5. On the left side two Anyridge


implants were placed, immediate implant
placement in area 24. Sinus lift with
simultaneous implant placement in area Fig 4 Fig 5
27.

Fig 6. No marginal bone loss, successful


aesthetic and functional outcome.

post op X-ray

7 years post op Fig 6

136­
Clinical Cases

➲ Clinical Case 4
- Courtesy of Prof. Giuseppe Luongo

Immediate post-extraction insertion of implant and immediate loading.

Before Surgery Fig 1. Clinical photos.

Fig 2. Intraoral scan.

Fracture of #21 tooth. Good stability Fig 3, 4. Clinical photos of 1st surgery.
of the hard and soft tissues suggests
immediate post-extraction insertion of Fig 5, 6. Clinical photos of implant posi-
implant and immediate loading. tioning.
Fig 1 Fig 2
Fig 7, 8. Clinical photo & scan of surgery.
Surgery
Fig 9, 10. Clinical photos of immediate
temporary crown in place.

Fig 11, 12. Clinical photos of healing and


final abutment in place.

Fig 13. Clinical photo of zirconia frame-


Fig 3 Fig 4 Fig 5 Fig 6
work in place.
To protect the esthetic outcome of the procedure, A 4.5×11mm Anyridge was placed in
the implant site was prepared via slightly palatal the prepared site. Fig 14, 15. Clinical photo & intraoral scan
alveolar access. of final crown at time of placement.

Fig 16, 17. Clinical photo & intraoral scan


of final crown at 1-yr follow-up.

Fig 18, 19. Clinical photo & intraoral scan


Biomaterial was added to the vestibular of final crown at 5-yr follow-up.
aspect to improve the stability of the
Fig 7 Fig 8 esthetic outcome.

Temporary Prosthesis 12 Weeks after surgery Final Prosthesis

Fig 9 Fig 11 Fig 13

The implant position was in


harmony with the surrounding
tissue and a prosthodontist
completed the case using
Fig 10 Fig 12 a zirconia framework.
A temporary crown was im- Tissue was ready to proceed
mediately placed. with final abutment and crown.

Fig 14 Fig 15 Fig 16 Fig 17

Fig 18 Fig 19

AnyRidge – 137
®

You might also like