You are on page 1of 1

523774.

03 - Communication Circuit Fault - tm13024x19 :: Service ADVISOR™ Page 1 of 1

tm13024x19 - 670G, 670GP, 672G and 672GP Motor Grader - 523774.03 -


Communication Circuit Fault

Controller area network (CAN) low circuit voltage is above 5 volts.


Alarm Level:
• Check Diagnostic Code Indicator
Machine Response:
• None
Circuit Information:
• See Advanced Display Unit (ADU) and Sealed Switch Module (SSM) Circuits Theory of
Operation . (Group 9015-15.)
• See Controller Area Network (CAN) Theory of Operation . (Group 9015-15.)
Component Location:
• See Cab Interior Harness (W15) Component Location-6WD . (Group 9015-10.)
• See Cab Interior Harness (W16) Component Location-Non 6WD . (Group 9015-10.)
JDG10273 Diagnostic Test Box Information:
• Not Applicable
Additional References:
• See Intermittent Diagnostic Trouble Code (DTC) Diagnostics . (Group 9015-20.)
• See Service ADVISOR™ Remote (SAR) Connection Procedure . (Group 9015-20.)
Possible Causes:
1. Check CAN circuit. See CAN Circuit Testing . (Group 9015-20.)
2. Software malfunction. Program controller.

AW70195,0000EA7-19-20130911

Copyright © Deere & Company, all rights reserved.