Professional Documents
Culture Documents
Application Abbreviation
For handling toxic, volatile, explosive or other fluids harmful to the
environment which require the application of hermetically sealed CMA 32 - 200/01 110/40 - W20
pumps without shaft seals. The liquids must not chemically attack
the materials of the pump/magnetic clutch. Series
Size
Type of construction / Installation Nominal discharge nozzle diameter
Horizontal volute-casing centrifugal pump, single-stage of the Nominal impeller diameter
direct coupled design with magnetic coupling. The casing
dimensions and hydraulic data correspond to DIN EN 22858 / Hydraulic-No.
ISO 2858.
Separated by the stationary can, the transmission of the torque is Shroud diameter
contactless from the outer to the inner rotor by means of
analogously arranged CoSm magnets. The outer magnetic rotor Maget length
is mounted on to the motor shaft. The inner magnetic rotor is
directly connected with a symmetric, double-flow impeller thus Material code
causing the resulting axial thrust to be reduced to almost zero.
Due to the between bearing mounting of the impeller, the resul- The designation is indicated on the name plate.
ting radial forces in the slidng bearings are reduced by 50%.
Materials
Recommended minimum flow rate: Qmin. = 0.3 x Qη opt. Pressure as a function of the media temperature
Flanges
Connection flange: dimensions according to EN 1092-1, PN 16. 13
Drive 12
By serial three-phase squirrel-cage induction motor. Up to 2.2 kW 0 50 t °C 100 150
220/380V, from 3 kW 400/660V, IP55.
1
M AG®
ALLM
Explosion protection
The pump fulfils the requirements according to EC
Explosion Protection Directive 94/9EG (ATEX 100a) for
equipment and equipment group II, category 2 G. Categorisation
into temperature classes according to EN 13463-1 depends on
the temperature of the pumped medium. The max. permissible
temperature of the pumped medium for the respective temperature
classes are shown in the below table:
Hazard Temperature class Max. permissible
category acc. to EN 13463-1 medium temperature
T4 103 °C
II 2G / c/b T3 150 °C ➀
II 3G / c T2 150 °C ➀
T1 150 °C ➀
2
M AG®
ALLM
Series CMA
Innovation Bearing Installation
Patented new pump concept Due to between bearing of Easy installation due to the
intelligent design solutions the impeller, reduction of the block-type construction no
radial forces (bearing load) coupling alignment required
Starting safety
Reduced GD2 at the inner
rotor due to non-shaft design
Performance graphs
80
20
60
H (m) H (ft.)
40
25-200/01 50-200/01
10
32-200/01
40-200/01 30
8
6 25-160/01 20
/01
/01
40-160/01
32-160
160
50-
4
3 10
2
1450 1/min
2 3 4 6 10 Q (m 3/h) 20 40 60 100
400
100
300
80
60 200
25-200/01 H (ft.)
1
1
00/0
1
40
00/0
00/0
50-2
32-2
40-2
100
H (m)
80
1
25-160/01
60/0
1
60/0
20
40-1
1
60/0
60
32-1
50-1
40
10
30
8
6
2900 1/min
20
2 3 4 6 10 20 Q (m 3/h) 60 100 200 300 400
FD
DNd b1 b2
bf
bf
h2
h3
d
a1
DNs
h1
c
4
m2
FD s for screw
m1 x b
w n2
a f l1 n1
l
Casing desing on suction side in size
25-160/01, 25-200/01, 32-160/01 and 32-200/01
Arrangement
58 k
4 holes
14
160
110
DNd
DNs
g Arrangement
8 holes
n = 1450 1/min
Base plate and/or foundation
Pump dimensions
Approximate dimensions
different depending upon
Flanges contained in
manufacturer
abbreviation
kW DNs DNd a f b1 b2 h1 h2 b c m1 m2 n1 n2 w y s a1 d h3 l1 l x
90 S # ➀ 1,1 181 130 282 641 24/200
25-160/01 40 25 80 279 135 135 132 160 50 15 100 70 240 190 280 28 M 12 250 195
90 L # ➀ 1,5 181 130 282 641 24/200
90 S # ➀ 1,1 181 130 282 630 24/200
25-200/01 40 25 80 268 135 140 160 180 50 15 100 70 240 190 270 - M 12 250 195
90 L # ➀ 1,5 181 130 282 630 24/200
90 S # ➀ 1,1 181 130 282 646 24/200
32-160/01 50 32 80 284 135 135 132 160 50 15 100 70 240 190 285 28 M 12 250 195
90 L # ➀ 1,5 181 130 282 646 24/200
90 S # ➀ 1,1 181 130 282 630 24/200
32-200/01 50 32 80 268 135 145 160 180 50 15 100 70 240 190 270 - M 12 250 195
90 L # ➀ 1,5 181 130 282 630 24/200
90 S # ➀ 1,1 181 130 282 644 24/200
40-160/01 65 40 80 282 135 135 132 160 50 15 100 70 240 190 285 28 M 12 250 195
90 L # ➀ 1,5 181 130 282 644 24/200
90 S # ➀ 1,1 181 130 282 653 24/200
40-200/01 65 40 100 271 135 150 160 180 50 15 100 70 265 212 270 - M 12 250 195
90 L # ➀ 1,5 181 130 282 653 24/200
90 S # ➀ 1,1 181 130 282 665 24/200
50-160/01 90 L # ➀ 1,5 80 50 100 283 135 135 160 180 50 15 100 70 265 212 285 - M 12 250 181 130 282 665 195 24/200
100 L # ➀ 2,2 3 203 158 312 695 28/250
90 S # ➀ 1,1 181 130 282 655 24/200
50-200/01 90 L # ➀ 1,5 80 50 100 273 140 160 160 200 50 15 100 70 265 212 275 - M 12 250 181 130 282 655 195 24/200
100 L # ➀ 2,2 3 203 158 312 685 28/250
➀ without support foot
h1 >
a1
or
d Base plate and/or foundation desing a1 d
h1 < or
2 2 without support foot 2 2
a1
a1
d
h1
h1
y
marking in table marking in table X
n = 2900 1/min
Base plate and/or foundation
Extensions dim.
Support foot
Motor size
Pump dimensions
Approximate dimensions
different depending upon
Flanges contained in
manufacturer
abbreviation
kW DNs DNd a f b1 b2 h1 h2 b c m1 m2 n1 n2 w y s a1 d h3 l1 l x
100 L # ➀ 3 203 158 312 671 28/250
279 250 195
25-160/01 112 M # ➀ 4 40 25 80 135 135 132 160 50 15 100 70 240 190 280 28 M 12 228 171 335 694 28/250
132 S X ➂ 5,5 7,5 322 300 266 196 413 815 237 38/300
100 L # ➀ 3 203 158 312 660 28/250
268 250 195
112M # ➀ 4 - 228 171 335 683 28/250
25-200/01 40 25 80 135 140 160 180 50 15 100 70 240 190 270 M 12
132 S # ➁ 5,5 7,5 311 300 266 196 413 804 237 38/300
160 M X ➁ 11 15 322 20 350 320 234 525 927 247 42/350
100 L # ➀ 3 203 158 312 676 28/250
284 250 195
112 M # ➀ 4 28 228 171 335 699 28/250
32-160/01 50 32 80 135 135 132 160 50 15 100 70 240 190 285 M 12
132 S X ➂ 5,5 7,5 327 300 266 196 413 820 237 38/300
160 M X ➁ 11 15 339 48 350 320 234 525 944 247 42/350
100 L # ➀ 3 203 158 312 660 28/250
268 250 195
112 M # ➀ 4 - 228 171 335 683 28/250
32-200/01 50 32 80 135 145 160 180 50 15 100 70 240 190 270 M 12
132 S # ➁ 5,5 7,5 311 300 266 196 413 804 237 38/300
160 M X ➁ 11 15 322 20 350 320 234 525 927 247 42/350
100 L # ➀ 3 203 158 312 674 28/250
282 250 195
112 M # ➀ 4 28 228 171 335 697 28/250
40-160/01 65 40 80 135 135 132 160 50 15 100 70 240 190 285 M 12
132 S X ➂ 5,5 7,5 325 300 266 196 413 818 237 38/300
160 M X ➁ 11 15 336 48 350 320 234 525 941 247 42/350
100 L # ➀ 3 203 158 312 683 28/250
271 250 195
112 M # ➀ 4 - 228 171 335 706 28/250
132 S # ➁ 5,5 7,5 314 300 266 196 413 827 237 38/300
40-200/01 65 40 100 135 150 160 180 50 15 100 70 265 212 270 M 12
160 M X ➁ 11 15 320 234 525 950 42/350
160 L X ➁ 18,5 325 20 350 320 234 525 950 247 42/350
180 M X ➁ 22 375 275 610 1035 48/350
100 L # ➀ 3 203 158 312 695 28/250
283 250 195
112 M # ➀ 4 - 228 171 335 718 28/250
132 S # ➂ 5,5 7,5 326 300 266 196 413 839 237 38/300
50-160/01 80 50 100 135 135 160 180 50 15 100 70 265 212 285 M 12
160 M X ➁ 11 15 320 234 525 963 42/350
160 L X ➁ 18,5 338 20 350 320 234 525 963 247 42/350
180 M X ➁ 22 375 275 610 1048 48/350
100 L # ➀ 3 203 158 312 685 28/250
273 250 195
112 M # ➀ 4 - 228 171 335 708 28/250
132 S # ➂ 5,5 7,5 316 300 266 196 413 829 237 38/300
50-200/01 160 M X ➁ 11 15 80 50 100 140 160 160 200 50 15 100 70 265 212 275 M 12 320 234 525 953 42/350
160 L X ➁ 18,5 328 20 350 320 234 525 953 42/350
247
180 M X ➁ 22 375 275 610 1038 48/350
200 L X ➁ 30 330 40 400 415 310 665 1095 55/400
➀ without support foot ➁ with support foot ➂ available with or without support foot