Fosroc Nitobond AR constructive solutions

Acrylic emulsion primer and bonding agent for


concrete repairs

Uses Instructions for use


Recommended primer and bonding agent for the Renderoc Surface preparation
Cementitious Repair System.
Clean the surface and remove any dust, unsound or contam-
inated material, plaster, oil, paint, grease, corrosion deposits
Advantages
or algae. Where breaking out is not required, roughen the
 Single component surface and remove any laitance by light scabbling or
 Simply brushed onto concrete as a primer grit-blasting.
 Provides excellent bond to concrete, masonry, stone- Expose fully any corroded steel in the repair area and
work, plaster and blockboard remove all loose scale and corrosion deposits. Steel should
 Suitable for use in Middle East conditions be cleaned to bright condition paying particular attention to
 Can also be used as a curing membrane for localised the back of the exposed steel bars. Grit-blasting is recom-
patch repairs mended for this process.

 Is economical in use Reinforcing steel priming

Description Apply one full coat of Nitoprime Zincrich*† to all exposed


steel reinforcement and allow to dry prior to continuing. If
Nitobond AR is a modified acrylic emulsion, specially any doubt exists about having achieved an unbroken film, a
designed for use as a bonding aid and curing agent for second application should be made and allowed to dry prior
concrete repair systems. It is resistant to hydrolysis and to continuing.
can therefore be used for external application.
Application of bonding aid
Technical support The substrate should be thoroughly soaked with clean water
Fosroc offers a comprehensive range of high performance, with any excess removed prior to commencement of the
high quality construction products. In addition, Fosroc works.
offers a technical support package to specifiers, end-users
Scrub Nitobond AR into the substrate, avoid ponding and
and contractors, as well as on-site technical assistance in
remove any excess. The repair mortar or topping should be
locations all over the world.
applied whilst the primer is still tacky.

Properties Curing

Slant shear adhesion Cure the repair mortar or topping using Nitobond AR to
(BS 6319 Pt 4; 1984) prevent rapid loss of water. In severe drying conditions
Typical result with AR : 9.0 N/mm² additional curing methods may be necessary. Protect
Curing efficiency uncured mortar from frost and rain.
BS 7542: 1992 : > 55%
Nitobond AR
Fosroc Nitobond AR

Cleaning Storage
Nitobond AR should be removed from tools, equipment and Shelf life
mixers with clean water immediately after use. Cured
material can only be removed mechanically. All products have a shelf life of 9 months on or below 20°C
if kept in a dry store in the original, unopened containers.
Limitations Shelf life is extendable based on revalidation request if the
 Nitobond AR mortars, toppings and renders should not be material stored as per manufacturer’s instructions.
used when the temperature is below 5ºC and falling.
Neither should they be exposed to moving water during Precautions
application. Exposure to heavy rainfall prior to the final
Health and safety
set may result in surface scour. If any doubts arise
concerning temperature, application or substrate condi- Cementitious mortars modified with Nitobond AR contain
tions, consult the local Fosroc office. cement powders which, when mixed or become damp
release alkalis which can be harmful to skin. During use
 Nitobond AR should not be used as a curing compound
avoid inhalation of dust and contact with skin and eyes.
when overcoating with epoxy coatings are required.
Wear suitable protective clothing, gloves and eye/face
However, it is suitable for Dekguard range. For epoxy
protection. The use of barrier creams provide additional skin
range use, Nitocote PE135.
protection. Should accidental skin contact occur, remove
 For priming in situations where the substrate will remain immediately with a resin removing cream followed by soap
permanently damp or the patch repair will be immersed in and water. Do not use solvent. In case of contact with eyes,
water after application, Nitobond EP primer should be rinse immediately with plenty of clean water and seek
used. medical advice. If swallowed seek medical attention immedi-
ately - do not induce vomiting.
Estimating Fire
Supply
Nitobond AR is non-flammable.
Nitobond AR : 1 and 5 litre cans

Coverage and yield


Nitobond AR : 6 - 8 m2 / litre as a primer
4 to 5 m2/litre as curing agent

* Denotes the trademark of Fosroc International Limited



See separate data sheet

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the Supply of
Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to obtain the latest version.

Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
Al Gurg Fosroc Co. LLC
Regional offices
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
www.fosroc.com Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com

UAE/0328/23/E