You are on page 1of 3

Test Equipment Solutions Datasheet

Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.

We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan
unit, if available) and supplying a free business tool with every order.

As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.

We are based near Heathrow Airport in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house
Lab.

All products supplied by Test Equipment Solutions include:

- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.

Test equipment Solutions Ltd


Unit 8 Elder Way
Waterside Drive
Langley
Berkshire
SL3 6EP

T: +44 (0)1753 596000


F: +44 (0)1753 596001

Email: info@TestEquipmentHQ.com
Web: www.TestEquipmentHQ.com
LOW RESISTANCE MEASUREMENTS

580 Micro-ohmmeter
• 10µΩ sensitivity

• 20mV voltage clamp

• Selectable test current wave-


forms

• 3 sets of test leads included

• Optional IEEE-488 interface

• Optional battery

O R D E R I N G I N F O R M AT I O N The 580 Micro-ohmmeter combines high accuracy, resolution, and sensitivity with three special
580 Micro-ohmmeter with 5804, capabilities that make micro-ohm measurements easier and more versatile than ever:
5805, 5806 Test Leads and 5801
Test Lead Pouch 1. When measuring contact and connector resistances, it is important not to puncture oxides and
580-1 Micro-ohmmeter without Test films that may have formed. The 580 ensures this dry circuit condition by clamping the open circuit
Leads and Pouch test voltage to 20mV on the 200mΩ, 2Ω, and 20Ω ranges when the 20mV MAX button is pressed.
580/5802 Micro-ohmmeter with Isolated
Analog Output/IEEE-488 2. The 580 can test more devices by enabling both test current polarity and waveform (DC or pulsed)
Interface to be selected. When using pulsed test current, the 580 automatically compensates for thermoelec-
580/1978 Micro-ohmmeter with tric EMFs. Tests on inductive devices are best performed using DC test current, as this avoids the
Rechargeable Battery Pack
effects of time constants on pulsed current resistance measurements. For temperature-sensitive
580/02/78 Micro-ohmmeter with Isolated
components, a single trigger mode of operation minimizes power delivered to the device. Single
Analog Output/IEEE-488
Interface and Rechargeable trigger operation is possible via the front panel.
Battery Pack
3. The optional IEEE-488 bus interface
This product is available with an Extended
Warranty. See section C for complete order-
permits operation as a stand-alone
ing information. unit as well as in a PC-based system.
A microprocessor-based design gives
the 580 a number of advanced capabil-
A C C E S S O R I E S AVA I L A B L E ities. Resistance measurements can be
TEST LEADS made from 10µΩ to 200kΩ on seven
5804 Test Lead Set ranges, with 41⁄2-digit resolution and
5805 Kelvin Probes, 0.9m (3 ft) accuracy to within 0.04% of reading.
5805-12 Kelvin Probes, 3.6m (12 ft) Ranging can be performed either man-
5806 Kelvin Clip Leads ually or automatically. Settling time is
5807-7 Helical Spring Point less than one second to within 10
Test Leads counts on a given range.
RACK MOUNT KITS
1010 Single Rack Mounting Kit
The 580 is supplied with three sets of
1017 Dual Rack Mounting Kit
test leads—standard leads, Kelvin
OTHER
probes, and Kelvin clip leads—in a rug-
1978 Rechargeable Battery
ged strap-on pouch. For applications
Pack requiring portability or line power iso-
5801 Test Lead Pouch lation, an optional battery pack is also
5802 Isolated Analog Output/IEEE-488 available. Digital calibration is possible
Interface through front panel controls or over
the optional IEEE-488 bus interface.
See page A-231 for descriptions of all acces-
sories.

QUESTIONS?
1-800-552-1115 (U.S. only)
The 580 is supplied with three sets of test
Call toll free for technical assistance,
product support or ordering information.
leads—standard leads, Kelvin probes, and
Kelvin clip leads—in a rugged strap-on pouch.
LOW RESISTANCE MEASUREMENTS

580 Micro-ohmmeter
NON DRY CIRCUIT TEST DRY CIRCUIT TEST GENERAL
ACCURACY MAXIMUM ACCURACY
DISPLAY: ±20,000-count LCD, range and
MAXIMUM 1 Year, 18°–28°C POWER 1 Year, 18°–28°C
TEST ±(%rdg + counts) DISSIPATION ±(%rdg + counts) status information displayed.
RANGE RESOLUTION CURRENT PULSED DC IN SAMPLE PULSED OVERRANGE INDICATION: “OL” displayed.
200 mΩ 10 µΩ 100 mA 0.04 + 2 0.04 + 3 500 µW 0.05 + 2 CONNECTORS: Measurement and rear panel
2 Ω 100 µΩ 10 mA 0.04 + 2 0.04 + 3 50 µW 0.05 + 2 EXTERNAL TRIGGER inputs: Banana jacks.
20 Ω 1 mΩ 1 mA 0.04 + 2 0.04 + 3 5 µW 0.05 + 2 RELATIVE: Allows zeroing of on-range read-
200 Ω 10 mΩ 1 mA 0.04 + 2 0.04 + 2 ings. Allows readings to be made with re-
2 kΩ 100 mΩ 1 mA 0.04 + 2 0.04 + 2 spect to baseline value. Display
20 kΩ 1 Ω 10 µA 0.05 + 2 0.05 + 2 annunciator indicates REL.
200 kΩ 10 Ω 10 µA 0.075 + 2 0.075 + 2 DRIVE: Selects either pulsed or DC SOURCE
current. Pulsed drive provides automatic
CONFIGURATION: 4-wire (two sense, two source). CONVERSION RATE: 3 readings/second typical. cancellation of thermal offsets, using 50%
MAXIMUM SOURCE VOLTAGE: 20mV in Dry Circuit Test, 1V RANGING: Auto or manual. duty cycle pulse. Display annunciator in-
otherwise. AUTORANGING TIME: 200 ms per range change, average. dicates drive selected.
MAXIMUM TEST LEAD RESISTANCE SETTLING TIME: <1 second to within 10 counts on range. POLARITY: Selects either positive or nega-
200mΩ and 2Ω Ranges: Up to 5Ω in each SOURCE lead and MAXIMUM INPUT OVERLOAD: 10V limited to 10A. tive SOURCE current in either drive. Dis-
10Ω in each SENSE lead with Non Dry Circuit Test; up to play annunciator indicates polarity
MAXIMUM COMMON MODE VOLTAGE: 30V rms at DC, 50 selected.
the selected full range resistance in each SOURCE lead
or 60Hz.
and 10Ω in each SENSE lead with Dry Circuit Test. TRIGGER: Allows single pulsed measurements.
TEMPERATURE COEFFICIENT (0°–18°C & 28°–50°C): ±(0.1
20Ω through 200kΩ Ranges: Up to half of the selected range OPERATING ENVIRONMENT: 0°–50°C, <80%
× applicable accuracy specification)/°C.
in each test lead. relative humidity up to 35°C; linearly derate
3% R.H./°C from 35° to 50°C.
STORAGE ENVIRONMENT: –25° to 60°C.
ISOLATED ANALOG OUTPUT/IEEE-488
POWER: 105–125V or 210–250V (switch select-
INTERFACE (Model 5802 Option) ed), 90–110V available. 50–60Hz, 12VA.
ANALOG OUTPUT Optional 6-hour battery pack, Model 1978.
LEVEL:1V = 10,000 counts on ×1 gain. DIMENSIONS, WEIGHT: 89mm high ×
1V = 100 counts on ×100 gain. 241mm wide × 300mm deep (31⁄2 in × 91⁄2
Maximum output voltage = ±4V. in × 113⁄4 in). Net weight 3.2kg (7 lb). Test
lead pouch adds 76mm (3 in) in height.
ACCURACY: ±(0.25% of displayed reading + 2mV). In ×100 , 2mV output
= 0.2 displayed counts. ACCESSORIES SUPPLIED: Models 5801,
5804, 5805, and 5806 test leads; Operator’s
RESPONSE TIME: Follows display conversion rate. and Service Manuals.
OUTPUT RESISTANCE: 1000Ω.
ISOLATION: ANALOG OUTPUT LO is connected to IEEE COMMON.
Maximum common mode voltage from IEEE COMMON to earth
ground is 30V rms at DC, 50 or 60Hz.

IEEE-488 BUS
IMPLEMENTATION
MULTILINE COMMANDS: DCL, SDC, GET,
GTL UNT, UNL, SPE, SPD, LLO.
UNILINE COMMANDS: IFC, REN, EOI, SRQ,
ATN.
INTERFACE FUNCTIONS: SH1, AH1, T5,
TE0, L4, LE0, SR1, RL0, PP0, DC1, DT1, C0,
E1.
PROGRAMMABLE PARAMETERS: Range,
DRY CIRCUIT TEST, Operate, RELative,
POLARITY, DRIVE, TRIGger, Calibration,
EOI, SRQ, Status, Data Format,
Terminator.

QUESTIONS?
1-800-552-1115 (U.S. only)
Call toll free for technical assistance,
product support or ordering information.

You might also like