SERVICE MANUAL
Models
HSU-18C03/V(ZXF)
HSU-18H03/V(ZXF)
HSU-22C03/V(ZXF)
HSU-22H03/V(ZXF)
! Features
! Comfortable:wide-angle airflow
! health air purifying
! quiet operation
! energy efficient
Content
2
Domestic Air Conditioner
DESCRIPTION OF
3
Domestic Air Conditioner
Introductory Remarks
Description of coding rules of unit model
Coding rules and descriptions are as follows:
1 2 3 4 5 6 7 8 9 10
Function Point
Developing sequence :A,B,C,D...
Applicable voltage:3(220~230V),4(240V)
Applicable frequency:0(50HZ),1(60HZ)
L/C-cooling only
Function code R/H-heat pump
E-electric aided heating
Nominal cooling capacity (BTU/h)with the first two
numbers based on thousand unit
The structure code of indoor & outdoor unit: S(wall-mounted),W(window type),P (cabinet type)
H-Abbreviation of Haier
Examples:
HSU-18H03/VA(ZXF),It represents wall-mounted split type heat pump air conditioner .
The cooling capacity is 18000BTU/h,and the power supply is 220-230V/50Hz,
4
Domestic Air Conditioner
Description of product model coding and series introduction
Standard Situation/Conditions
indoor air status outdoor air status
No. Operating condition DB C
O
WBOC DB C O
WBOC
3 Norminal electrical
heating --- --- --- ---
1.comfortable:wide-angle airflow
The vertical dual-flap and horizontal wide-angle louvers ensure the cool(warm) air reaches every
corner of the room.
3.Quiet operation
Fan With Random-pitched Blades.
Random-pitched blades help reduce operating noise while maintaining a high airflow rate.
4.Engergy efficient
The design of inner-grooved copper tube greatly increases the refrigerant contact area and the
efficiency of cooling/heating functions.
5.Convenience
Auto restart and washable panel:
The grille can be removed easily and washed when necessary.Any series have the function then
even if the power falls when the unit is operating unit will automatically return to the operating
settings in use before the power failure when power is restored.
7.Night-set models
When the air conditioner is operationg on the timer-off circuit.The preset room temperature
gradually rises(going down in heating)before the unit stops as shown delow.Users can sleep
comfortably without sudden change in temperature.
8.Program”dry”
This function automatically reduces the level of humidity while maintaining the preset indoor
temperature.
Domestic Air Conditioner
Specifications
Domestic Air Conditioner
7
Domestic Air Conditioner
8
Domestic Air Conditioner
9
Domestic Air Conditioner
10
Domestic Air Conditioner
11
Domestic Air Conditioner
TH338VEE
CONDENSING
50Hz 220V
TEMPERATURE
FLOW RATE O
C
160
150
40
140 45
50
55
130 60
120
110
(KG/HR)
11.3
10.3
40
AMPS 45
9.3 50
55
8.3 60
(A)
2140
40
WATTS 2040
45
INPUT
1940 50
1840 55
60
1740
(W)
8390
40
7390 45
50
55
CAPACITY 6390
60
4390
(W)
4 5 6 7 8 9 10
O
C
0 1 2 3
evaporating temperature 0.7 MPa(A)
0.5 0.55 0.6 0.65
suction pressure R-22
12
Domestic Air Conditioner
2700
60
2500
55
INPUT(W)
2300
50
2100
45
1900
-5 0 5 10
13.0
12.0 60
CURRENT(A)
55
11.0
50
10.0
45
9.0
-5 0 5 10
(W)
9000
45
8400 50
CAPACITY
7800 55
60
7200
6600
6000
5400
4800
10
-5 0 5
EVAPERATING TEMP. ( C)
O
13
Domestic Air Conditioner
14
Domestic Air Conditioner
Indoor unit
Inlet grille
Anion generator
Vertical flap (inside)
(adjust up and down air flow.
Don't adjust it manually) Power plug
Horizontal louver
(adjust left and right air flow)
Outdoor unit
HSU-18C03/V(ZXF) HSU-22C03/V(ZXF)
HSU-18H03/V(ZXF) HSU-22H03/V(ZXF)
15
Domestic Air Conditioner
NE T DIME NSIONS FOR INDOOR UNIT
780 197
250
540
68
HSU-18C03/V(ZXF)
HSU-18H03/V(ZXF)
HSU-22C03/V(ZXF)
HSU-22H03/V(ZXF)
16
D
17
Domestic Air Conditioner
18
17
16
19
15
20 21 22
14
13 23
24
12
25
11 27
36 26
10 29 28
9
30
8
6
7
5
31
4
2
3 34
32
1
35
33
18
Domestic Air Conditioner
T
N S
S M T F
1 F 001020 55 SU 18 0 F 1
2 F EFT 001020 558 SU 18 0 F 1
F RI T 001020 559 SU 18 0 F 1
F U 001020 555 SU 18 0 F 1
5 F DO N 001020 55 SU 18 0 F 1
R EFT 001020291 SU 18 0 F 1
7 R MID 0010202207 SU 18 0 F 1
8 I U 001020 55 SU 18 0 F 1
9 S 001020 5 5 SU 18 0 F 2
10 D 0010101 9 SU 18 0 F 1
11 F 001020 552 SU 18 0 F 1
12 E 001070 8 0 SU 18 0 F 1
1 001080525 SU 18 0 F 1
1 F F 001020 SU 18 0 F 1
15 D 001080550 SU 18 0 F 1
1 D 0010805509 SU 18 0 F 1
17 F 0010805 95 SU 18 0 F 1
18 M 0010101 8 SU 18 0 F 1
19 S M SIDE 0010 02 SU 18 0 F 1
20 S M EFT 0010 01870 SU 18 0 F 1
21 S M RI T 0010 01871 SU 18 0 F 1
22 N I 0010 00 7 SU 18 0 F 1
2 M 001 000088 SU 18 0 F 1
2 M 001020 5 9 SU 18 0 F 1
25 E 0010 0 58 SU 18 0 F 1
2 T 0010 01858 SU 18 0 F 1
27 S 001020 550 SU 18 0 F 1
28 0010 0 2 SU 18 0 F 1
29 S 001020 551 SU 18 0 F 1
0 0010201995 SU 18 0 F 1
1 R 001 1 5 SU 18 0 F 1
2 R 0010 0 2 SU 18 0 F 1
00108029 SU 18 0 F 1
D 001 1 0 9 SU 18 0 F 1
5 SU 18 0 F 1
0010 00115 SU 18 0 F 1
1T ;T
2 ;T "*"
T
""
T T
T " "
T FO
19
Domestic Air Conditioner
T
N S
S M T F
1 F 001020 55 SU 18 0 F 1
2 F EFT 001020 558 SU 18 0 F 1
F RI T 001020 559 SU 18 0 F 1
F U 001020 555 SU 18 0 F 1
5 F DO N 001020 55 SU 18 0 F 1
R EFT 001020291 SU 18 0 F 1
7 R MID 0010202207 SU 18 0 F 1
8 I U 001020 55 SU 18 0 F 1
9 S 001020 5 5 SU 18 0 F 2
10 D 0010101 9 SU 18 0 F 1
11 F 001020 552 SU 18 0 F 1
12 E 001070 8 0 SU 18 0 F 1
1 001080525 SU 18 0 F 1
1 F F 001020 SU 18 0 F 1
15 D 001080550 SU 18 0 F 1
1 D 0010805509 SU 18 0 F 1
17 F 0010805 95 SU 18 0 F 1
18 M 0010101 8 SU 18 0 F 1
19 S M SIDE 0010 02 SU 18 0 F 1
20 S M EFT 0010 01870 SU 18 0 F 1
21 S M RI T 0010 01871 SU 18 0 F 1
22 N I 0010 00 7 SU 18 0 F 1
2 M 001 000088 SU 18 0 F 1
2 M 001020 5 9 SU 18 0 F 1
25 E 0010 0 221 SU 18 0 F 1
2 T 0010 01858 SU 18 0 F 1
27 S 001020 550 SU 18 0 F 1
28 0010 0 1 SU 18 0 F 1
29 S 001020 551 SU 18 0 F 1
0 0010201995 SU 18 0 F 1
1 R 001 1 5 SU 18 0 F 1
2 R 0010 015 0 SU 18 0 F 1
00108029 SU 18 0 F 1
D 001 1 0 9 SU 18 0 F 1
5 SU 18 0 F 1
0010 00115 SU 18 0 F 1
1T ;T
2 ;T "*"
T
""
T T
T " "
T FO
20
Domestic Air Conditioner
The proportion
No. in exploded Spare parts
Spare parts number Model QTY. Failure rate of the spare remark
view description in english
part stock
1 Front Panel 0010203553 HSU-22H03/VA(ZXF) 1 Y
2 Air Filter (LEFT) 0010203558 HSU-22H03/VA(ZXF) 1
3 Air Filter (RIGHT) 0010203559 HSU-22H03/VA(ZXF) 1
4 Flap (UP) 0010203555 HSU-22H03/VA(ZXF) 1
5 Flap (DOWN) 0010203556 HSU-22H03/VA(ZXF) 1
6 Rotor (LEFT) 0010202914 HSU-22H03/VA(ZXF) 1
7 Rotor (MID) 0010202207 HSU-22H03/VA(ZXF) 1
8 Inlet Grille (UP) 0010203554 HSU-22H03/VA(ZXF) 1
9 Screw Cover 0010203565 HSU-22H03/VA(ZXF) 2
10 Decorate Bar 0010101439 HSU-22H03/VA(ZXF) 1
11 Front Cover 0010203552 HSU-22H03/VA(ZXF) 1
12 Evaporator Assy. 0010706841 HSU-22H03/VA(ZXF) 1 Y
13 Bearing 0010805256 HSU-22H03/VA(ZXF) 1
14 Cross Flow Fan 0010203643 HSU-22H03/VA(ZXF) 1
15 Display Panel Assy. 0010805506 HSU-22H03/VA(ZXF) 1
16 Drain Pan Assy. 0010805509 HSU-22H03/VA(ZXF) 1
17 Frame Assy. 0010805495 HSU-22H03/VA(ZXF) 1
18 Mounting Plate 0010101438 HSU-22H03/VA(ZXF) 1
19 Swing Motor (SIDE) 0010402433 HSU-22H03/VA(ZXF) 1 Y
20 Swing Motor (LEFT) 0010401870 HSU-22H03/VA(ZXF) 1 Y
21 Swing Motor (RIGHT) 0010401871 HSU-22H03/VA(ZXF) 1 Y
22 Negative Ion Generator 0010400337 HSU-22H03/VA(ZXF) 1 Y
23 Motor 001A3000088 HSU-22H03/VA(ZXF) 1 Y
24 Motor Cover 0010203549 HSU-22H03/VA(ZXF) 1
25 Electricity Power Cord 0010403221 HSU-22H03/VA(ZXF) 1 Y
26 Terminal Block 0010401858 HSU-22H03/VA(ZXF) 1 Y
27 Service Box 0010203550 HSU-22H03/VA(ZXF) 1
28 PCB 0010403461 HSU-22H03/VA(ZXF) 1 Y
29 Service Cover 0010203551 HSU-22H03/VA(ZXF) 1
30 Wires Cover 0010201995 HSU-22H03/VA(ZXF) 1
31 Guard Ring 001A1433544 HSU-22H03/VA(ZXF) 1
2,easy-damaged;The spare-part which is often damaged and the customer must stock in the spare-parts warehouse,and should be marked with"*"
3,possible damaged:The spare-part which is not often damaged like the easy damaged one and the customer may stock in the spare-part warehouse
accord with the actual case,should be marked with " ".
4,not need provided :The spare-part which is seldom damaged or the maintenance man could not maitmains.The spare parts may be air freighted by the
factory if they were damaged.The customer nees not stock in the spare-part warehouse,should be marked with " x ".
5,Above should be improved accord with the reply of the market half a year per time.
21
Domestic Air Conditioner
11
13
12
31
30
10
9
19
18
15
16
17
14
22
23
24
20
21
7
6
28
8
29 26
25
27
5
4
3
2
22
Domestic Air Conditioner
The proportion
No. in exploded Spare parts
Spare parts number Model QTY. Failure rate of the spare remark
view description in english
part stock
1 001A1436043 Front grille HSU-18C03/V(ZXF) 1
2 001A1101009 Front panel HSU-18C03/V(ZXF) 1
3 001A5102021 Nut HSU-18C03/V(ZXF) 1
4 001A2331030A Axial fan HSU-18C03/V(ZXF) 1
5 0010100418 Bracket for fan motor HSU-18C03/V(ZXF) 1
6 0010705439 Condenser HSU-18C03/V(ZXF) 1
7 0010805646 Left-support HSU-18C03/V(ZXF) 1
8 001A1101010 Panel(top ) HSU-18C03/V(ZXF) 1
9 0010704101 Discharge tube HSU-18C03/V(ZXF) 4
10 0010706596 Capillary assy. HSU-18C03/V(ZXF) 1
11 001A5002001 Screw HSU-18C03/V(ZXF) 1
12 0010705949 Service valve HSU-18C03/V(ZXF) 1
13 0010705947 Service valve HSU-18C03/V(ZXF) 1
14 / Nut HSU-18C03/V(ZXF) 1
15 / Service cover HSU-18C03/V(ZXF) 3
16 / Protector for compres HSU-18C03/V(ZXF) 1
17 001A5102050 Nut HSU-18C03/V(ZXF) 1
18 0010701856 Compressor HSU-18C03/V(ZXF) 1 *
19 / Rubber cushion HSU-18C03/V(ZXF) 1
20 0010704102 Suction tube HSU-18C03/V(ZXF) 1
21 001A4000184 Terminal block HSU-18C03/V(ZXF) 1 *
22 001A3600030 Capacitor for compresHSU-18C03/V(ZXF) 1 *
23 001A1301023 Electric box HSU-18C03/V(ZXF) 1
24 001A4400389 Wire group HSU-18C03/V(ZXF) 1
25 001A1434045 Cushion HSU-18C03/V(ZXF) 1
26 001A1301022 Separating plate HSU-18C03/V(ZXF) 1
27 001A1436042 Service cover HSU-18C03/V(ZXF) 1
28 0010805512 Bottom plate assy. HSU-18C03/V(ZXF) 1
29 0010402624 Fan motor HSU-18C03/V(ZXF) 1 *
30 0010805645 Back beam HSU-18C03/V(ZXF) 1
31 0010805644 Back broad HSU-18C03/V(ZXF) 1
1,The failer rate and the proportion of the spare-part stock are regarded as the reference of the stock for spare-parts;The first time should be
stocked accroded with the proportion of the spare-parts,and it should be adjusted with the actual quantity 3 months later.
2,easy-damaged;The spare-part which is often damaged and the customer must stock in the spare-parts warehouse,and should be marked with"*"
3,possible damaged:The spare-part which is not often damaged like the easy damaged one and the customer may stock in the spare-part
warehouse accord with the actual case,should be marked with " ".
4,not need provided :The spare-part which is seldom damaged or the maintenance man could not maitmains.The spare parts may be air freighted
by the factory if they were damaged.The customer nees not stock in the spare-part warehouse,should be marked with " x ".
5,Above should be improved accord with the reply of the market half a year per time.
23
Domestic Air Conditioner
15
25
16
10
17
20
9
18
19
12 13
21
11
14
7
6
8
23
22
5
24
4
3
2
24
Domestic Air Conditioner
The proportion
No. in exploded Spare parts
Spare parts number Model QTY. Failure rate of the spare remark
view description in english
part stock
1 001A1436043 Front gril HSU-18H03/V(ZXF) 1
2 001A1101009 Front panel HSU-18H03/V(ZXF) 1
3 001A2331030A Fan HSU-18H03/V(ZXF) 1 *
4 0010402624 Motor HSU-18H03/V(ZXF) 1 *
5 0010100418 Motor support HSU-18H03/V(ZXF) 1
6 0010703786 Heat exchanger HSU-18H03/V(ZXF) 1 x
7 0010101388 Back grille HSU-18H03/V(ZXF) 1
8 001A1101010 Tope panel HSU-18H03/V(ZXF) 1
9 0010701898 4-way valve winding HSU-18H03/V(ZXF) 1 *
10 0010703643 Tube assay. HSU-18H03/V(ZXF) 1 x
11 001A3600030 Capacity for compres HSU-18H03/V(ZXF) 1 *
12 001A3600018 Capacity for motor HSU-18H03/V(ZXF) 1 *
13 001A4000092 Terminal block HSU-18H03/V(ZXF) 1 *
14 001A1301023 Electric box HSU-18H03/V(ZXF) 1
15 0010703642 Stop valve HSU-18H03/V(ZXF) 1
16 0010702407 Stop valve HSU-18H03/V(ZXF) 1
17 \ Terminal cover HSU-18H03/V(ZXF) 1
18 \ Protect HSU-18H03/V(ZXF) 1
19 0010701856 Compressor HSU-18H03/V(ZXF) 1 *
20 \ Rubber cushion HSU-18H03/V(ZXF) 3
21 001A4400389 Wire HSU-18H03/V(ZXF) 1
22 001A0100030 Separating plate HSU-18H03/V(ZXF) 1 x
23 0010805512 Bottom plate assy HSU-18H03/V(ZXF) 1 x
24 001A1436042 Service cover HSU-18H03/V(ZXF) 1
25 0010802091 Fresh air device HSU-18H03/V(ZXF) 1
1,The failer rate and the proportion of the spare-part stock are regarded as the reference of the stock for spare-parts;The first time should be
stocked accroded with the proportion of the spare-parts,and it should be adjusted with the actual quantity 3 months later.
2,easy-damaged;The spare-part which is often damaged and the customer must stock in the spare-parts warehouse,and should be marked with"*"
3,possible damaged:The spare-part which is not often damaged like the easy damaged one and the customer may stock in the spare-part
warehouse accord with the actual case,should be marked with " ".
4,not need provided :The spare-part which is seldom damaged or the maintenance man could not maitmains.The spare parts may be air freighted
by the factory if they were damaged.The customer nees not stock in the spare-part warehouse,should be marked with " x ".
5,Above should be improved accord with the reply of the market half a year per time.
25
Domestic Air Conditioner
33
20
21
22
19
11
10
23
24
25
26
27
13
31 28
18
12
14
17
32
15
16
9
7
8
30
5
29
4
3
21
26
Domestic Air Conditioner
The proportion
No. in exploded Spare parts
Spare parts number Model QTY. Failure rate of the spare remark
view description in english
part stock
1 001A1303126A Front grille HSU-22H03/V(ZXF) 1
2 001A1101038 Front panel HSU-22H03/V(ZXF) 1
3 001A2331024 Fan HSU-22H03/V(ZXF) 1
4 0010401909 Motor HSU-22H03/V(ZXF) 1
5 001A1301133 Motor support HSU-22H03/V(ZXF) 1
6 0010706480 Heat exchanger HSU-22H03/V(ZXF) 1 X
7 001A0100356 Side panel assy.(L) HSU-22H03/V(ZXF) 1
8 001A1436182 Handle HSU-22H03/V(ZXF) 1
9 001A0100124 Top panel assy. HSU-22H03/V(ZXF) 1
10 001A0100125 Service cover assy. HSU-22H03/V(ZXF) 1
11 001A0100126 Side panel(R) HSU-22H03/V(ZXF) 1
12 ———— Back grille HSU-22H03/V(ZXF) 1
13 0010701900 4-way valve HSU-22H03/V(ZXF) 1
14 001A2500004 4-way valve coil HSU-22H03/V(ZXF) 1
15 001A3600030 Capacitor for comp. HSU-22H03/V(ZXF) 1
16 001A3600098 Capacitor for motor HSU-22H03/V(ZXF) 1
17 0010805968 Electric box assy. HSU-22H03/V(ZXF) 1
18 001A4000092 Terminal block HSU-22H03/V(ZXF) 1
19 0010706481 Pipe assy. HSU-22H03/V(ZXF) 1
20 0010702454 Two-way stop valve HSU-22H03/V(ZXF) 1
21 001A5002074 Screw HSU-22H03/V(ZXF) 4
22 0010702420 Three-way Stop valve HSU-22H03/V(ZXF) 1
23 001A5102021 Nut for fan HSU-22H03/V(ZXF) 1
24 ———— Terminal cover HSU-22H03/V(ZXF) 1
25 001A5102050 Nut for compressor HSU-22H03/V(ZXF) 3
26 0010701848 Compressor HSU-22H03/V(ZXF) 1
27 ———— Rubber cushion HSU-22H03/V(ZXF) 3
28 001A4400044 Wires HSU-22H03/V(ZXF) ——
29 001A0100237 Bottom plate assy. HSU-22H03/V(ZXF) 1 X
30 001A0100127 Separating plate assyHSU-22H03/V(ZXF) 1 X
31 001A1762341 Sound insulation cush HSU-22H03/V(ZXF) 1
32 001A1762340 Sound insulation cush HSU-22H03/V(ZXF) 1
33 0010802091 Fresh air device HSU-22H03/V(ZXF) 1
1,The failer rate and the proportion of the spare-part stock are regarded as the reference of the stock for spare-parts;The first time should be
stocked accroded with the proportion of the spare-parts,and it should be adjusted with the actual quantity 3 months later.
2,easy-damaged;The spare-part which is often damaged and the customer must stock in the spare-parts warehouse,and should be marked
with"*"
3,possible damaged:The spare-part which is not often damaged like the easy damaged one and the customer may stock in the spare-part
warehouse accord with the actual case,should be marked with " ".
4,not need provided :The spare-part which is seldom damaged or the maintenance man could not maitmains.The spare parts may be air
freighted by the factory if they were damaged.The customer nees not stock in the spare-part warehouse,should be marked with " x ".
5,Above should be improved accord with the reply of the market half a year per time.
27
Domestic Air Conditioner
control functions
28
Domestic Air Conditioner
HSU-18C03/V(ZXF) HSU-18H03/V(ZXF)
HSU-18H03/V(ZXF) HSU-22H03/V(ZXF)
.ETC
Countersign
29
Domestic Air Conditioner
2.2 Cooling run mode: (Tr: inlet air temperature,Ts the set temperature)
The background lighting of the LCD is blue
Temperature control range : 16 30
Temperature control precision: ±1
Compressor can’t be controlled by temperature sensor within 2 minutes after it starts.
Control character: when Tr> Ts, outdoor fan motor and compressor on, and indoor fan
motor run at fixed wind speed. When Tr < Ts, outdoor fan motor and compressor off, and when Tr
> Ts, outdoor fan motor and compressor are working again.
If Tr=Ts, the indoor fan motor,outdoor fan motor and the compressor’s state will not change.
wind speed control: (the temperature difference is 1 )
auto: when Tr>=Ts+3 , the wind speed is high;
when Ts+1 ≤Tr <Ts+3 , the wind speed is medium.
When Tr<Ts+1 , the wind speed is low.
When temperature sensor is off, the fan motor runs at low speed.
when the wind speed changes from low to higher, there is no delay, and when
it changes from high to lower, there is a 3-minutes delay before conversion.
Manual operation: When unit is on the wind speed can be set to high, medium, low or
30
Domestic Air Conditioner
31
Domestic Air Conditioner
Manual operation: When the temperation sensor is off or the Indoor fan motor runs
intermittently, the indoor fan motor can not be operated by hand (compelling automatic
operation), along with the indoor fan motor can be operated in cooling mode. While
controlling fan motor by hand in cooling mode, the cooling ranges include wind speed
setting and refriferation range, others are the same as fan motor in automation mode.
compressor control The compressor can’t be controlled by temperature sensor in 2 minutes
after startup and also can’t be started again at least 3 minutes later after shutdown. There are
3-minutes protection with power on for the first time (over 3 minutes with power off). The
compressor must be started again 3 minutes later after shutdown.
There is no 2-minutes limit when changing the temperature setting or shutting off the
machine through the remote controller, and the machine can be shut down immediately.
Avoiding electrical shock: outdoor fan motor is available 2 seconds later after compressor
startup.
Controlling the position of air door: set the position of air door as required.
Protection of expiration of current peak value is available: Current cross detection is
available in order to avoid burning out the compressor when the current is too big. The action
character as follows: The compressor can’t be detected in 60 seconds after startup. when current
is above “CT 1.6 V” and lasts 3 seconds, the system enter protection mode and shut off
compressor with outdoor air blower and indoor fan motor controlled as the temperature sensor is
off. After 3 minutes the machine can be started again.
Protection of frost is available (disable in test run or heating mode): In order to prevent the
indoor heat exchanger from freezing (in refrigation or dehumidifying mode), the compressor
will be shut off when the temperature of the indoor coil pipe is or below 0 and the
compressor runs for over 5 minutes. When the temperature of the indoor coil pipe ascends
to over 7 , the compressor is restarted (must meet a 3-minutes delay)
Timer on, Timer off and sleep control are available.
2.4 Heating mode: (Tr: inlet air temperature,Ts the set temperature)
The background lighting of the LCD is red
Temperature control range : 16 30
Temperature control precision: ±1
Control Character:
When Tr ≤ Ts, compressor, four-ways valve and outdoor fan motor is on, indoor fan
motor runs as in cold blast avoidance mode, and 4 of compensation is added after
compressor is started.
When Tr Ts+5 , compressor is off, and the indoor fan motor runs as in cold blast
avoidance mode.
When Tr<Ts+5 , compressor, four-ways valve and outdoor fan motor is on, and the
indoor fan motor runs as in the mode of avoiding cold blast.
Control of indoor fan motor:
Manual operation: The wind speed can be set to high, medium, low or automatic as required.
Automatic operation: When Tr < Ts, the wind speed is high;
When Ts=<Tr<Ts+2 , the wind speed is medium.
When Tr>= Ts+2 , the wind speed is low.
Control of air door: setting the position of air door as required.
32
Domestic Air Conditioner
33
Domestic Air Conditioner
Overcooling protection:
One and a half minute later after compressor starts, if the temperature of coil pipe is
below -4 , compressor and air outlet stop, and air inlet runs according to the temp.
setting. Compressor can be restarted 3 minutes later.
Defrosting:
1.Entry conditions of defrosting:
A. Indoor unit enter overload protection and air outlet stops when air outlet has been
restarted and runs over 10 minutes, and compressor runs over 45 minutes in total
and over 20 minutes continuously, and the temp. of indoor coil pipe is below 42 .
B. Compressor runs 20 minutes continuously, and the temp. of indoor coil pipe
decreases 1 per 6 minutes and this operation repeats 3 times, and the temp. of
coil pipe is below 42 , then 5 minutes later . the system enters defrosting mode.
C. When compressor runs over 3 hours in total and over 20 minutes continuously and
after the temp. of indoor coil pipe is below 42 , the system enters defrosting mode.
D. The difference between the temp. of indoor coil pipe and the indoot temp. is below
18 and lasts 5 minutes, compressor runs over 45 minutes in total and over 20
minutes continuously, the temp. of indoor coil pipe is below 42 , the system enters
defrosting mode.
2.Exit conditions of defrosting:
Defrosting time is higher than 12 minutes (compressor is on), or CT current is above
(CT0.6).
! During the defrosting, if current peak value is cut off, the unit quit the defrosting mode.
But the protection of expiration of current peak value is unavailable with 60 senconds
after compressor is started.
! During the defrosting and 2 minutes after the defrosting, abnormality of temp. sensor
isn’
t detected.
! After quiting the defrosting mode, the fan motor enter cooling prevention mode.
3.Defrosting oscillogram:
34
Domestic Air Conditioner
35
Domestic Air Conditioner
! Detect the temperature of inlet air is below -20 , then think the temperation circuit of
inlet air is open.
! Detect the temperature of inlet air is above 90 , then think the temperation circuit
of inlet air is short.
4.4 Emergency switch imput:
! Press the switch of emergency operation, then buzzer rings once and unit enters the
automatic operation mode. (emergency operation)
! If the switch is kept pressed for 5 seconds, buzzer ring two times and unit enter enter
test run mode.
! Press the switch again, and then closes.
! The unit can receive remote control.
! Enter emergency operation from timer mode, then timer is cancelled.
! Test run:
1) The temperature sensor of inlet air doesn’t work, and compressor starts (but
subject to the limit of -minute delay excluding the first time), and high wind, cooling,
and air door is open.The indoor fan motor runs, running indicator lights up,
compressor relay and the one of outdoor fan motor is closed
2) During test run:
! The prevention of freezing of evaporator doesn’t work.
! Over current control doesn’t work.
! The control of current peak expiration doesn’t work.
! Temperature control doesn’t work.
! Temperature expiration control doesn’t work.
! The test run is over after 30 minutes,then the unit turn off
4.5 Executive function after 2 seconds by remoter control:
After receiving remote control signal, the mainboard doesn’t enter the corresponding
instruction task until 2 seconds elapse.
!# The memory function of power down is available, and the auto recovery function of power
on is optional. (In auto, heating, cooling, or defrosting status, press the “sleeping” button 10
times within 5 seconds, and the auto recovery function of power on can be set on/off. If the
buzzer rings 4 times, the the auto recovery function of power on is available; If the buzzer
rings 2 times, the the auto recovery function of power on is unavailable.)
4.6 Alarm from indoor fan motor: 120 seconds later after the indoor fan motor is charged, and
the impulse from fan motor is not detected, then stop outputting voltage to indoor fan motor, send
alarm signals.
4. 7 Manual defrosting: when the wire controller is on, choose high wind, 30 , and press the
sleeping button for 6 times within 5 seconds, and after the buzzer rings 3 times, the
air conditioner enter manual defrosting mode, which is the same as heating
defrosting.
36
Domestic Air Conditioner
37
Domestic Air Conditioner
Wiring diagram
38
Domestic Air Conditioner
HSU-18C03/V(ZXF) HSU-22C03/V(ZXF)
HSU-18H03/V(ZXF) HSU-22H03/V(ZXF)
2
W B R BR
3 4
39
Domestic Air Conditioner
HSU-18C03/V(ZXF)
HSU-18H03/V(ZXF)
40
Domestic Air Conditioner
HSU-22C03/V(ZXF)
HSU-22H03/V(ZXF)
41
Domestic Air Conditioner
CIRCUIT DIAGRAM
42
+12v BEEP-PKM13EPY-4002
+5 +5 R54 POWER 472/1KV
T1
E10 12V L1 20UH E11 IC7
+5
R52 3.6/3W C31 TRAN1-3 D8 UF302 470U/25V
2
4
R61
1K Q817C E14
+5 Q5 IC8 4.7K 100U/16V
Q4 R18 C17
5
2SC2412 15
4.7k
R27 10K 2SC2412 103/50v R75
2 220V-N D IC13
CN9 Q1
Vcc
HV
DRV
NC
1 R66 27
R30
2SC2412 ZE1 C
STD2NBP60
C12 C40 S14K350 IC6 NCP1200P60 S D7 R55
102
GND
104/275V
ADJ
10K CON21 10K 10V/0.5V 560
FB
CS
+12V R59 FUSE1 R76
R31 4.7K E9
1
47U/35V
10K T3.15A R60
4
220V-L 220VL
R62 1.0/2W
+5 39K
R41 1K 22
02 IRQ VDD
C33 222/300VAC
R28 1K R9 4.7K 07
C5 102 PTF3/TBCH3 C18 E5
Q2
11 104/50V 100u/16v
2SC2412 PTF5
12
PTF6 +5 CN8
48
PTH1/KBD3 R45 1K 1 ROOM TEMP.
36
SW1 +5V +5 PTB2/ATD2 2
R2 10K R42 10K 49 37
PTH1/KBD4 PTB3/ATD3 3 PIPE TEMP.
R29 10K
switch R3 1K D2 RLS4148
08
PTF4/TBCH0 C10
R44 1K
E7 4.7UF/50V
4 C3861
102 C9 R34 20K 1%
102 4.7UF/50V
(° ×) 102/50V
C1 03 C41 R35 3.3K 1%
E6
64 C22
102 RST
PTF0/TACH2 04 102 REMOT 102/50V
E1 C13 21
VSS GND PTC1 61
R53 1K 1
63 C23
R85 330 2
1UF/16V 104 45
AVSS/VRE GND
PTC5 64
R69 100 3 103/50V
56
PTC3 63
R68 100 4 62 C24
VSSA GND PTC2/MCLK 62
PTD7 53
R67 100 5 103/50V
PTD6/TACLK 52
R70 330 6
53 C25
60 R71 330 7
PTC0 PTD5 51 R72 330 8 102/50V
R10 10K
10
PTF7
OSC1 59
9 52 C26
C2 104
57 C47 10 102/50V
CGMXFC E13
CON5-1 51 C27
+5V 09 103/50V 100u/16v
R37 10K NC +5V 102/50V
+5V
R50 51K +5V
1
R7 10K
+5 R36 1K
4 OSC2 58
CN7
1
2
R14 1K 3
13
14
PTE0/TXD
VREFH
55 +5 R1 XT1
R8 10K IC2
CN6 2 PTE1/RXD 54 1M 8M 5 4
3 VDDA SDA
C43 C16 1 C4 C3 C14 6 3
104 SCL
103 102 104 103 7 2
PG Feedback NETWORK(R) 15
PTE2/TACH0 PG Feedback PTG0/KBD0 23 8 24C01A 1
2
25 PTG1/KBD1
PTG2/KBD2 4-way volva 24
220V-L
R23 4.7K 16 06
PTE3/TACH1 PG out PTF2/TBCH2
17 05
PTE4/SS COMP PTF1/TACH3
18
PTE5/MISO FRESH AIR VDDAREF 44
19 +5 O2
4-WAY VOLVE PTE6/MOSI AION
20 PTD3 47 A +12 CON16(B)
PTE7/SPSCK OUTDOOR FAN C6 C7
PTD2 46 B
103/50V
104/50V
Q3 heater Q9 1
2SC2412 01 PTC4 PTD1 43 C D15
220V-N
PTD0 42 D
2SC2412 R40 4.7K
RLS4148
PTB7/ATD7 41 A
220V-L RL2
CON12 C39 +5
R19 4.7K R21 4.7K
PTD6/ATD6 40 B
+12V PTB5/ATD5 39 C JAQ-1 12V CON20
2UF 450V
1 IC10 R20 22K A 26 +5 COMP.
2 RC1 R22 22K
PA0
SHORT TIME PTB1/ATD1 35
R46 R24
B 27 1
3 PA1
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
34 1K 10K
R25 22K C 28 CT PTB0/ATD0 C15
PA2 C8 CON21
0.01U*120/300V TLP3526
IC3 C11
D 29
PA3 102
102
IC5 C20
220VL
R57 2003 R73
R48 22K A 30
PA4 2003
104 RL1
1
104 R26 4.7K B 31 +12
680 +12 4.7K C 32
PA5
ZJ1
G4A-1A-P
2
1
5v PA6 SHORT TIME CON14(R)
D 33
PA7
D 38 1
16
15
14
13
12
11
10
9
16
15
14
13
12
11
10
9
+12V E12 SW2 PTB4
D5 +5 FLZ1
1
2
3
4
5
6
7
8
R64 100u/25v 50 PTD4
RL3
220V-N
FRESH AIR
10K COMP.
IC4 R43 1K
IN4148
G5N-1A
CON15(W)
R56 2003 C19
FRESH AIR CN4
104 MC68HC908AB32 CN3 1
5
4
3
2
1
5
4
3
2
1
1K +12
R39 R38 FLZ2
CON18¡ ¢ CON19 SWEEP MOTOR SWEEP MOTOR D10 RL4 220N
Q8 2SB1182 +5v 1K 390 1
16
15
14
13
12
11
10
9
R33 10K VR1
G5N-1A
RLS4148 STF
2
+12 CN10 4-WAY
R32 1K CT1 WFJ
3
OUTDOOR FAN 1 E3 W04
C21 2 BD2
102 RL5 CON13
AION SWITCH B3P5-VH-3/(B£ ©
470U/16V OUTDOOR FAN JAQ-1 12V
MOL-35979-0314
1
2
3
4
5
6
7
8
9
10
CN2
SWEEP MOTOR
Domestic Air Conditioner
TROUBLE SHOOTING
44
Domestic Air Conditioner
45
Domestic Air Conditioner
46
Domestic Air Conditioner
47
Domestic Air Conditioner
48
Domestic Air Conditioner
Noise level test chart and air velocity distribution
dB(A)
60 60
50 50
40 40
30 30
20 20
10 10
0 0
63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz
indoor
outdoor
49
Domestic Air Conditioner
Noise level test chart and air velocity distribution
m2 unit m/s
Fig 1 1
top view
flow control panel horizal 0 2.0 1.0 0.5 0.25
lourer:center 1
2
1
m
2 3 4 5 6 7 8 9 10
m3
unit m/s
Fig 3 3
top view 1.8
flow control panel horizal 2.0 1.0 0.5 0.25
lourer:center 1
m
0 1 2 3 4 5 6 7 8 9 10
uni t m /s
m
3.0
Fig 4 Condition
top view 2.0 Fan speed:high
flow control panel vertical
1.8
Operation mode:fan
lourer:center Voltage:230V,50Hz
1.0
0.5
0 1 2 3 4 5 6
m
0.25
50
Domestic Air Conditioner
Installation manual
51
Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Accessory parts
Number
No. Accessory parts of
articles
1 Remote controller 1
mo
re th
3 1 Optional parts for piping an
10c
m
8 1
Drain-elbow
9 Cover 1
Arrangement of piping directions C
10 Cushion 4 Rear left mo
re
tha m
Left Rear n1 10c
0c an
right m re th
11 Connecting cable 1 mo
Right
Change for Below
12 fresh air box
1
Change for
13 fresh air tube(suit) 1 12
14 Outlet joint 2 13
D
15 Outlet joint 1
E
60cm
than
more more
Note:1.Cooling only units don't have Drain-elbow than
15c
m
2. 14 is only for the models of 18,22.
52
HSU-09C03/VA(ZXF) HSU-12C03/VA(ZXF) HSU-18C03/V(ZXF) HSU-22C03/V(ZXF)
HSU-09H03/VA(ZXF) HSU-12H03/VA(ZXF) HSU-18H03/V(ZXF) HSU-22H03/V(ZXF)
319.5
280
256
140 415 140 140 500 140
113.5 583 113.5
Fixing of outdoor unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Place, robust not causing vibration, where the body can be supported Place, which is less affected by rain or direct sunlight and is
sufficiently. sufficiently ventilated.
Place, not affected by heat or steam generated in the vicinity, where Place, possible to bear the unit, where vibration and noise are
inlet and outlet of the unit are not disturbed. not increased.
Place, possible to drain easily, where piping can be connected with the Place, where discharged wind and noise do not cause a
outdoor unit. nuisance to the neighbors.
Place, where cold air can be spread in a room entirely. Place, where a distance marked is available as illustrated
Place, nearby a power receptacle, with enough space around. (Refer in the above figure.
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
Power Source
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated HSU-12C03/VA(ZXF)
HSU-09C03/VA(ZXF) HSU-12H03/VA(ZXF) HSU-22C03/V(ZXF)
as they become Iow temperature in operation. HSU-09H03/VA(ZXF) HSU-18C03/V(ZXF) HSU-22H03/V(ZXF)
HSU-18H03/V(ZXF)
Use optional parts for piping set or pipes covered with
equivalent insulation material. Liquid pipe( ) 6.35mm(1/4") 6.35mm(1/4") 9.52mm(3/8")
53
Indoor unit
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
70mm
35
A=170mm
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 70 mm in diameter, Indoor side Outdoor side
slightly descending to outside the wall.
Wall hole Thickness
Install piping hole cover and seal it
of wall
off with putty after installation 70mm
54
Indoor unit
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then
connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Heat insulation
material
Piping
signal wire
55
Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
WHT WHT
BLK BR
BLK
RED
YEL/GRN YEL/GRN RED
1(L) 2(N)
BLK YEL/GRN RED
BLK WHT BR
Indoor unit YEL/GRN BLK WHT
Indoor unit YEL/GRN
HSU-18C03/V(ZXF) HSU-18H03/V(ZXF)
Outdoor unit To outdoor fresh air motor
HSU-22C03/V(ZXF) HSU-22H03/V(ZXF) Outdoor unit
The connecting method of
fresh air box signal wire
Outlet joint
(in guard ring)
Joint of water
collecting pan Fresh air tube
Guard ring
Fresh air tube
Outlet joint
Figure 3
Outdoor unit
2.Connection of pipes
To bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius
should be 30 to 40 mm or longer.
Connecting the pipe of gas side first makes working easier.
The max vertical distance between the indoor unit and the outdoor unit is 5 m.
3.Connection
Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into
terminal block, then tighten the screws.
Insert the cable according to terminal number in the same manner as the indoor unit.
If wiring is not correct, proper operation can not be carried out and controller may be damaged.
Fix the cable with a clamp.
4.Attaching Drain-Elbow
If the drain-elbow is used, please attach it as
figure. (Note: Only for heat pump unit.)
57
Outdoor unit
5.Installation instruction on the outdoor part of the fresh air device
1.Remove the four screws of fresh air box from the back cover.
2.Use six screws to fix fresh air box onto the designated position on the outdoor unit.
3.Remove two screws of the pipe junction of the fresh air box, then insert the flared departure of
the change for fresh air tube into the pipe junction and then fix with the screws.
4.Use four screws to fix the fresh air box onto the back cover, as illustrated:
Screw Back
hole cover Fresh air tube
Flared departure
Change-for-fresh-air box Fresh air box
Fresh air tube Dust Fresh air
Screw
filtration box Screw
Connecting terminal mesh Joint of tube
Fresh air signal wire Fresh air tube
(with guard ring)
Note:After wiring, the connecting terminals of outdoor unit and change-fresh-air as well as the wiring sheath should be
placed in the change-for-fresh-air box against the rain.
6.Purging Method:
Push the air out of the indoor unit
and piping as followes: 2-way valve
6.35mm(1/4")
(1) Remove the valve cap on 2-way
valve in outdoor unit. 3-way valve
(2) Loosen by 1/2 turn the flare nut of 9.52mm(3/8")
gas pipe, which is conneted to
3-way valve.
o HSU-09C03/VA(ZXF)
(3) Loosen 2-way valve by 90 using HSU-09H03/VA(ZXF)
hexagon wrench, and after approx. HSU-12C03/VA(ZXF)
10 sec tighten it up. Gas comes out HSU-12H03/VA(ZXF)
through flare nut on wide pipe. If no
gas is discharged, tighten flare nut
2-way valve 3-way valve
with specified torque.
6.35mm(1/4") 12.7mm(1/2")
(4) Open 2-way and 3-way valves
using specified torque. 2-way valve 3-way valve
9.52mm(3/8") 15.88mm(5/8")
(5) Tighten the caps on the valves
with specified torque.
Note: When extending piping, air inside piping shall be removed by using external
refrigerant gas, charge according to the following list.
Brand new outdoor unit is charged 50g more refrigerant than regulated weight.
Only for first installation, this extra 50g can be used to purge air in pipes.
During this procedure, 50g refrigerant will be discharged in piping.
o
(This must be strictly controlled within 90 and 10 sec.)
58
1.Power Source Installation
The power source must be exclusively used for air conditioner. (Over I0A)
In the case of installing an air conditioner in a moist place, please install an
earth leakage breaker.
For installation in other places, use a circuit breaker as far as possible.
4.Flare pipe
Lean Damage of flare Crack Partial Too outside
3.On Drainage
Please install the drain hose so as to be downward slope without fail.
Please don't do the drainage as shown below.
It becomes high The end is immersed It waves. The gap with the ground There is the bad smell
midway. in water. is too small from a ditch
Please pour water in the drain pan of the indoor unit, and confirm that drainage is
carried out surely to outdoor.
In case that the attached drain hose is in a room, please apply heat insulation
to it without fail.
Check for Installation and Test Run
Please kindly explain to our customers how to operate through the instruction manual.
Check Items for Test Run Put check mark in boxes
Gas leak from pipe connecting? Is drainage securely carried out? Is the lamp normally lighting?
Heat insulation of pipe connecting? Is the earth line securely Are cooling and heating (when
Are the connecting wirings of connected? in heat pump) performed normally?
indoor and outdoor firmly inserted Is the indoor unit securely fixed? Is the operation of room temperature
to the terminal block? Is power source voltage abided regulator normal?
Is the connecting wiring of indoor by the code?
and outdoor firmly fixed? Is there any noise?
59