You are on page 1of 2

ECAFLOW

150 GLP

L ABORATORY ANALYSER

EcaFlow Model 150 GLP is a PC controlled puter controlled electromagnetic valves for
automatic laboratory analyser for the deter- switching either to the sample solution or TECHNICAL DATA
mination of trace and high concentrations to an electrolyte solution or to a standard
POTENTIOSTAT/GALVANOSTAT:
of metals, semi-metals and numerous non- solution for the standard addition. Solu- 12 V / 20 mA
metals in various samples. By making use of tions are driven by a peristaltic pump. The
the autosampler AS-150 up to 42 samples heart of the system is the patented com- MEASURING CELL:
EcaCell 353c or EcaCell 104 with three elec-
can be analysed in full automatic mode. The pact electrochemical cell.
trodes
system supports the standardless, calib-
ration curve and standard additions tech- The cell uses disposable flow-through working FLOW SYSTEM:
niques. Over 70 validated applications are electrodes made of suitable inert material. Full computer control with peristaltic pumping
available for numerous sample types such The counter and reference electrodes are se-
WEIGHT: 7 kg
as waters, foods, industrial liquids, wastes, parated from the flowing solutions hydrodyna-
etc. EcaFlow is a compact laboratory instru- mically, so the reaction products at the coun- DIMENSIONS:
ment controlled by a PC. ter electrode cannot interfere at the working 500 x 450 x 140 mm
electrode. The working electrode can be easily SOFTWARE:
The control unit contains the power su- changed simply by loosening a screw. The cell Chronopotentiometry, coulometry, voltammetry
pport unit, control processor with a chan- is fixed to the panel of the instrument by a spe-
nel analyser, fast A/D and D/A converters cial connector which serves as an electrical COMPUTER (OPTION):
Any PC with Windows XP and higher
and a high performance generic poten- contact to the electrodes. The connections of
tiostat/galvanostat. The compact flow the tubes are made of Luer-type fitting, which AUTOSAMPLER (OPTION):
system is controlled by the control unit and facilitates fast manipulation when the electro- 42 positions + blank + standard
operates full automatically. It contains com- de or cell is changed.

Istran, s.r.o., Žitná 42, 831 06 Bratislava, Slovakia +421 2 52 63 31 71 istran@istran.sk www.istran.sk
AVAILABLE APPLICATIONS
ALL INCLUDED
1 Flow-through analyser test 41 Acidimetry determination of strong
3 Simultaneous determination and weak acids
of Cd, Pb and Cu 42 Determination of Fe in concentrated
4 Determination of Pb sulphuric acid
5 Simultaneous determination 43 Determination of Cu in waste waters
of Sn and Pb 44 Alkalimetry determination of strong
6 Simultaneous determination bases
of Pb, Cd and Hg 45 Simultaneous determination
7 Determination of EDTA of total As and Hg
8 Simultaneous determination 46 Determination of Zn in galvanic baths
of Zn, Cd, Pb, and Cu 47 Determination of Ni in galvanic baths
9 Simultaneous determination 48 Chlorides in galvanic baths
of Cd, Pb, a Cu in wines 49 Cr(III) in passivating galvanic baths
10 Determination of Ag 50 Determination of phosphates with
11 Determination of As(III) and total microporous electrodes
As in urine 51 Determination of sub-ppb Hg
12 Determination of As(III) and total concentrations
As in fertilisers 52 Determination of Zn in waste waters
13 Determination of Se in waters 53 Cu in wine samples
14 Determination of Mn 54 Determination of Fe in clear and
15 Determination of Hg turbid water samples
16 Determination of Fe in waters 55 Determination of Au in ores
17 Determination of Sn 56 Determination of Sb in the presence
18 Determination of Bi of As and Cu
19 Determination of As in drugs 57 Determination of low Se
20 Determination of chlorides in waters concentrations
21 Simultaneous determination 58 Sulphites in wines
of Zn, Cd, Pb, and Cu in wines 59 Sulphites in beers
22 Simultaneous determination 60 Titanium in TiO2
of Zn, Cd, Pb, and Cu in spirits 61 Determination of phosphates in clear
23 Simultaneous determination as well as turbid water samples
of Cd, Pb, and Cu in beers 62 Determination of total ammonia
24 Determination of Fe (higher in underground and tap waters
concentrations) in waters 63 Determination of total ammonia
25 Determination of Cd, Pb, and Cu in waste waters
in soil extracts 64 Determination of Cr(VI) in clear as
26 Determination of Sb well as turbid water samples
27 Simultaneous determination 65 Determination of Ni in clear as well
of Zn, Cd, Pb, and Cu in waters as turbid water samples 2-
28 Determination of As(III) and 66 Determination of sulphides (S )
total As in waters in waste waters
29 Determination of Zn, Cd, Pb, 67 Simultaneous determination of Zn,
and Cu in pectines Cd, Pb, and Cu in turbid samples
30 Determination of iodides in urine 68 Coulometric determination of sulphi-
31 Determination of Au in water samples des in waters
32 Determination of low Ni contents 69 Acid content in wines
33 Determination of iodides in foods 70 Ethanol in beverages
and beverages 71 Sulphites (SO3 ) in foods
34 Determination of Cr(VI) and 72 Chlorides (Cl ) in foods
total Cr in waters 73 Chlorites (ClO2 ) in disinfected water
35 Determination of nitrates in waters 74 Manganese (Mn) in aquatic samples
36 Determination of Ascorbic Acid 75 Bromides (Br ) in water
37 Determination of chlorites in waters 76 Cd, Pb and Cu in concentrated
38 Determination of bromates in waters zinc sulphate
39 Boric acid in nickel plating baths 77 Simultaneous determination
40 Determination of total As in waters of Pb, Cu and Hg in waters

Istran, s.r.o., Žitná 42, 831 06 Bratislava, Slovakia +421 2 52 63 31 71 istran@istran.sk www.istran.sk