You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12

LIMI
T OF
WOR
K

E=356100

E=356200

E=356300

E=356400

E=356500

E=356600
N
ROAD
-1

KING FAISEL ROAD

LIM
IT
OF
WO
RK
L.O.W
EXISTING
ROAD

-1
ROAD

OF WORK
LIMIT
SHEET 01 SHEET 04

T
EE
TR
HS

D
BA

ROA

T
LIMI

EAS RNISH
SA
T OF
WOR

REE
K

A A

AL-
LIMI
T OF

OUQ
WOR
K

T ST
O
AL-C
AL-S
bus
stop

bus stop

Al-KHOR STREET

N=2830800 N=2830800 N=2830800


SHEET 02 SHEET 03

DONE BY OTHERS KEY PLAN


(UNDER DESIGN)
NOTES:
4Cx1
6mm
B 1CX1 ² CU/XLP CK-1/SL
6mm -F
² ECC E/SWA/M P-1
1. ALL DIMENSIONS & COORDINATES ARE IN METERS UNLESS B
DPE
CABL
E (TY +
P.) OTHERWISE NOTED.
2. FOR TYPICAL CROSS SECTION MARKER & CROSS SECTIONS REFER
ROA
DRAWING NO (CI-RD-CSM-101,CI-RD-CS-101 THRU CI-RD-CS-104).

3.65
D -1

3.65
SUBS
TATIO
3. DURING CONSTRUCTION THE CONTRACTOR TO VERIFY ALL THE
N
EXISTING SERVICE AND THE SAME SHOULD BE PROTECTED AS PER
CK-2
/S
4Cx1 L-FP-1 THE AUTHORITY STANDARDS.

2W
6
1CX1 mm² CU/X
4. ALL THE PROPOSED STREET LIGHTING POLES, FEEDER PILLARS,

3.65
6mm
² ECC LPE/SWA
CABL /MD
E (T PE+
YP.) LUMINARIES ETC MATERIALS SHALL BE HIGH CORROSION FREE,

2W
SUITABLE FOR MARINE GRADE.

2W
5. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE CONDITION OF
PRO
PO
FEED SED GR EXISTING STREET LIGHTING COMPONENTS AND REUSE THE SAME,

2W
E P
SL-F R PILLAR
N=2830700 P-01
N=2830700 IF APPLICABLE AFTER OBTAINING THE CLIENT/ENGINEER'S
N=2830700

2W
GRP W
METE ITH
R CA
BIN ET APPROVAL.

2W
C C
6. THE PROPOSED DESIGN IS BASED ON THE AUTHORITY

2W
EXIS REGULATION AND INTERNATIONAL STANDARDS. HOWEVER, THE
TING
ROA
D CONTRACTOR IS RESPONSIBLE TO VERIFY THE NEARBY ROAD
-1

LIGHTING DESIGN AND THE SAME MUST BE HIGHLIGHTED TO THE


A D
RO

2W

2W CLIENT/ ENGINEERS FOR THEIR CONFIRMATION OF THE LIGHTING


PARAMETERS.

LEGEND:
9.1
0 PROPOSED UPSTAND KERB
PROPOSED DROP KERB
PROPOSED FLUSH KERB

REFER TO DRAWING NO.CI-SL-LP-104


2.0
0 EXISTING FLUSH KERB

1C 16mm FP-1
4C 2/SL-
PROPOSED R.O.W BY OTHERS

CK
X1
x
6m ² CU

-
D D


PROPOSED R.O.W

E CC LPE/S
/X
PROPOSED PEDESTRIAN FENCE

CA
BL A/MD
EXISTING UPSTAND KERB

E
W
(TY PE+
PROPOSED HEEL CURB

P.)
N=2830600 N=2830600 N=2830600
L.O.W - LIMIT OF WORK

MATCH LINE
PROPOSED PARKING
EXPROPRIATION AREA
PROPOSED 60MM INTERLOCKING
PROPOSED ASPHALT
EXISTING ASPHALT
EXISTING INTERLOCKING
DESIGNED BY OTHER CONSULTANT
E HERITAGE BUILDING E

2W

2W
AL-HISN ROUNDABOUT
2W

N=2830500 N=2830500 N=2830500


2W

2W

F
PRELIMINARY DESIGN
2W

F
2W

2W

PRELIMINARY DESIGN ISSUE AEH APR-2023 PD00


DESCRIPTION APPROVED DATE REV NO
AL-HIS CLIENT
N ROA
HERITAGE 14
D
L.O
.W
STREET LIGHTING LEGEND:
CONSULTANT
PR.10m HIGH POLE WITH 1x(60-75)W LED LUMINAIRE P.O.Box 60833,Dubai G
LED
G United Arab Emirates
LED LED
PR.10m HIGH POLE WITH 2x(60-75)W LED LUMINAIRE Phone:+971(4)2953440

LED
Fax: +971(4)2953445
RO ING

N=2830400 N=2830400 N=2830400


H
D

Email:rtceng@rtceng.com
RT

PR.10m HIGH POLE WITH 3x(60-75)W LED LUMINAIRE


EA

PRP.FP01/CT4/P11 LED
D LED
LE
D
LE PROJECT TITLE
PROPOSED STREET LIGHTING CABLE
0

PRP.FP01/CT4/P10 (XLPE/SWA/MDPE Cu)


45.0

69/2019 IMPROVEMENT OF AL KHOR STREET, UMM AL QUWAAIN


EX.10m HIGH POLE WITH 150W HPSV TO BE REMOVED
T JUNCTION 01 Class Eav Uo ANGULAR
Class Eav Uo EX.10m HIGH POLE WITH 150W HPSV TO BE REMOVED DRAWING TITLE
REQUIRED 10.0 0.4 PARKING-01 STREET LIGHTING NETWORK LAYOUT
CE4 LED REQUIRED 10.0 0.4 SL PROPOSED STREET LIGHTING DUCT (SHEET 01 OF 04)
ACHIEVED 16.0 0.55 LED PRP.FP01/CT4/P09 CE5
ACHIEVED 11.0 0.59 PROPOSED FEEDER PILLAR DATE
H EARTHING JOB NO. DRAWING NO.
ROD
PROPOSED EARTHING PIT CI-SL-LP-101 APR-2023 H
45.00

2101094-125
LED

PROPOSED INCOMER CABLE


L.O.W

DRAWN BY CHECKED BY APPROVED BY


E=356100 E=356100

E=356200 E=356200

E=356300 E=356300

E=356400 E=356400

E=356500 E=356500

E=356600 E=356600
F PROPOSED SOLAR POWERED FLASH LIGHT
EXISTING FEWA SUBSTATION TR AJ AEH
SL
3W MATCH LINE
SCALE - 1:1000@A1 REV NO. PD00
REFER TO DRAWING NO.CI-SL-LP-102
1 2 3 4 5 6 7 8 9 10 11 12
Original Drawing Size A1