Professional Documents
Culture Documents
Topic
SC3020 Replacement
Selections
Choose an Option: Hard Drives
REPORT PROBLEMS
If you find any errors in this procedure or have comments regarding this application, send email to
SolVeFeedback@dell.com
Copyright © 2023 Dell Inc. or its subsidiaries. All Rights Reserved. Dell Technologies, Dell, EMC, Dell
EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be
trademarks of their respective owners.
The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of
any kind with respect to the information in this publication, and specifically disclaims implied warranties of
merchantability or fitness for a particular purpose.
Use, copying, and distribution of any software described in this publication requires an applicable
software license.
This document may contain certain words that are not consistent with Dell's current language guidelines.
Dell plans to update the document over subsequent future releases to revise these words accordingly.
This document may contain language from third party content that is not under Dell's control and is not
consistent with Dell's current guidelines for Dell's own content. When such third party content is updated
by the relevant third parties, this document will be revised accordingly.
Page 1 of 5
Contents
Preliminary Activity Tasks .......................................................................................................3
Read, understand, and perform these tasks.................................................................................................3
Page 2 of 5
Preliminary Activity Tasks
This section may contain tasks that you must complete before performing this procedure.
Table 1 List of cautions, warnings, notes, and/or KB solutions related to this activity
2. This is a link to the top trending service topics. These topics may or not be related to this activity.
This is merely a proactive attempt to make you aware of any KB articles that may be associated with
this product.
Note: There may not be any top trending service topics for this product at any given time.
Page 3 of 5
Hard Drives
The SCv3000 and SCv3020 storage system supports hot-swappable hard drives.
The drives are installed from left to right, and then top to bottom. The first row of drives are numbered
from 0–4 from left to right, the second row of drives are numbered from 5–9 from left to right, and so on.
A minimum of 4 SSDs or 7 drives must be installed in the chassis or in an expansion enclosure. The
SCv3000 and SCv3020 storage system supports a maximum of 16 or 30 drives installed in the chassis.
The drives are installed from left to right, and then top to bottom. The first row of drives are numbered
from 0–4 from left to right, the second row of drives are numbered from 5–9 from left to right, and so on.
Dell Storage Manager identifies drives as XX-YY, where XX is the number of the unit ID of the storage
system and YY is the drive position inside the storage system.
Figure 1. SCv3000 Storage System Drive Numbering
Page 4 of 5
4. Find the drive with the status of Down.
5. Record the location of the drive from the Name column.
• Before removing the drive, make sure that the following alert is displayed in the Alerts tab of Dell
Storage Manager:
Drive # is ready to be removed., where # is the drive position in the storage system.
• Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the
Storage Center to Maintenance mode.
Steps
1. Open the release handle on the drive carrier and insert the hard drive carrier into the open drive
slot.
2. Slide the drive into the slot until the drive carrier contacts the midplane.
3. Close the drive carrier handle to lock the drive in place.
4. Continue to push firmly until you hear a click and the drive carrier handle fully engages.
5. Clear the drive swap status from the Hardware tab in Dell Storage Manager.
For instructions, see the Storage Manager Administrator’s Guide.
Next steps
Page 5 of 5