Professional Documents
Culture Documents
Cable type
Renewed V2 series with
V2 series high-level specifications
Longest in class 70 m sensing distance (through-beam type)
Model
Sensing distance (Models in parentheses are connector types)
Type Shape (Adjustable distance range shown Supply voltage
in parentheses) NPN type PNP type
24 to 240 VAC
24 to 240 VDC V2T-7000 V2T-7000
Through-
70 m
beam
10 to 30 VDC V2T-7000DN V2T-7000DP
(V2T-7000CDN) (V2T-7000CDP)
24 to 240 VAC
Detection of vehicle protrusion in 24 to 240 VDC V2R-1200 V2R-1200
Retro-
parking structures reflective
0.01 to 12m
10 to 30 VDC V2R-1200DN V2R-1200DP
(V2R-1200CDN) (V2R-1200CDP)
For the connector type, please purchase an optional DOL-1204-G02M connector cable.
Photoelectric
Renewed V2 series with high-level specifications
Longest in class 70 m sensing distance (through-beam type)
Sensors
A through-beam type that achieves a 70 m sensing distance; 3.5 longer than the conventional model. Support has been
increased for long distance detection applications.
Conventional models
Sensing distance: 20 m
Photoelectric
Sensing distance Sensors
Universal
Voltage
Easy-to-see dual indicators All models equipped with a sensitivity adjustment potentiometer V2
New easy-to-use
M12 pivot type connector Relay for universal voltage type
Uses a pivot type connector An IP67 relay with VDE
where the connector can standard certification is
be turned downward or to equipped.
the rear. Offers drastic The relay has double layer
improvements in mounting structure for dust and water
flexibility. resistance (IP67) and contact
capacity has been increased
to 3A (250 VAC).
Specifications
Photoelectric
Laser
Displacement Power consumption 3 VA or less 2 VA or less
Sensors
Applicable regulations EMC directive (2004/108/EC), Low voltage directive (2006/95/EC)
Applicable standards EN 60947-5-2
Universal
Voltage Company standards Noise resistance: Feilen Level 3 cleared
Ambient temperature/humidity -25 to +55°C (no freezing) / 35 to 85% RH (no condensation)
V2
Environmental
Options/Accessories
Reflector Protective mounting bracket
Standard (included) Small type Ultra-durable 3 mm thick type Rust-resistant stainless steel
Sensor is firmly secured using M4 Hex socket head cap screws
The bracket is also firmly secured using M6 screw
LV2 series
V-61 V-42
Sensing distance: Sensing distance:
0.01 to 12 m 0.01 to 7 m
60.9 × 50.9 mm 42 × 35 mm
LV2-S01 LV2-S02
Photoelectric
DC power type
Type
Sensors
Through-beam type Retro-reflective type
Cable type V2T-7000DN V2R-1200DN
NPN
Connector type V2T-7000CDN V2R-1200CDN
Model
Cable type V2T-7000DP V2R-1200DP
PNP
Connector type V2T-7000CDP V2R-1200CDP
Sensing distance 70 m 0.01 to 12 m*
Light source Red LED
Smallest detectable object ø15 mm 40 mm
Response time 0.5 ms or less Photoelectric
Sensors
Distance adjustment 2-turn endless potentiometer (with indicator)
Indicators Output indicator: orange LED, Stability indicator: green LED (no indicator equipped on through-beam type emitter) Specialized
Photoelectric
Control output NPN/PNP type Open collector Max. 100 mA/30 VDC Sensors
Output mode Light ON / Dark ON wiring switching
Laser
Connection type Cable type: Cable length: 2 m ø3.8 mm / Connector type: M12, 4-pin Displacement
Sensors
Insulation resistance 20 MΩ or more (with 500 VDC)
Supply voltage 10 to 30 VDC, including 10% ripple (p-p)
Rating
Universal
Current consumption 35 mA or less Voltage
Applicable regulations EMC directive (2004/108/EC)
V2
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 3 cleared V3, V4
Ambient temperature/humidity -25 to +55°C (no freezing) / 35 to 85% RH (no condensation)
V
Ambient illuminance Sunlight: 10,000 lx Incandescent lamp: 3,000 lx
Environmental
resistance
Connector cable
Straight
DOL-1204-G02M
M12, 4-pin connector cable
Cable length: 2 m
*5 m and 10 m cables are separately available.
Load
White: 2
Output mode
input
Main circuit
Main circuit
Photoelectric
Sensors
Black: 4
Control output
Specialized
Photoelectric
Sensors
Protection
Laser circuit
Displacement
Sensors Blue: 3 0V Blue: 3 0V
*For the universal voltage type, add 24 to 240 VAC / 24 to 240 VDC
Universal to the brown wire and blue wire. (No polarity)
Voltage
V2
Output relay
Main circuit
Connecting
Black Turns to Light ON mode when the white wire is connected to +V or not
N.O. connected and to Dark ON mode when connected to 0 V (for NPN). To use
N.C. without connecting, disconnect and wrap individually with insulating tape, etc.
Do not connect it to any other terminal.
Gray
1 to 4 are connector pin No.
Notes
White When using a switching regulator for the power supply, be sure to ground the
COM frame ground terminal.
Avoid wiring in parallel with or in the same piping as high-voltage wires or
power lines. Doing so may lead to malfunctions caused by noise. Also, shorten
the power supply and signal wires as much as possible.
Avoid using the transient state while the power is on (approx. 150 ms).
Photoelectric
Sensor (Unit: mm)
Through-beam type
Sensors
Cable type Connector type
Emitter
Receiver
V3, V4
Retro-reflective type V
Cable type Connector type
Output indicator (orange)
Distance adjustment
4.9
Optical axis 36
of emitter
16.8 60 65
19 18.6 23.6
10
Universal voltage ø6.4, 5-wire × 0.32 mm2
DC power ø3.8, 4-wire × 0.2 mm2 36.3
Dimensions
Photoelectric
45
39.5
R34 20
2-M4
16° 22
22
Photoelectric
Sensors
Specialized 22 67.6
2-M4
Photoelectric 2 1.5
2-ø4.2
2 2.4 23.7
Sensors Tightening torque:
0.5 N·m or less
Laser 20
Displacement 46
Sensors 39.5
70
R34
Universal 14 16°
Voltage 28.6 19.1
10
V2
22
V3, V4
2-R3.25
25.1 7 25.1
6.5
12
R3.25
57
13 20 12
Light axis center position
Light axis center position (refer to the table below) 33
2-ø5
(refer to the table below) 33 16
2-ø5 16
b 4-R2.5
b 103
4-R2.5 82
66 87
a
a 10°
7 6.5
10°
3
20.2 3 12
20.2 57
13 20 12
V2T-7000 V2R-1200
a - (30.4 mm) 30.4 mm
b 16.8 mm 16.8 mm
Photoelectric
Mounting bracket (Unit: mm)
Sensors
BEF-W250 (included with product)
9-R2.1
45 2-R5
36
2
5.4
21 3 Specialized
Photoelectric
Sensors
Reflector
Laser
V-61: Standard type reflector (included with retro-reflective type) V-42: Small reflector (optional) Displacement
Sensors
Universal
Voltage
50.9
60.9 V2
35
42 V3, V4
V
5 3.2
4.3
10 10 6
8.5 3.5
40 25
2- ø3.6 8
50.9 3.1 35
O-ring
M12 × 1 ø10.5
ø8.8 ø10.3
Typical characteristic data *Contact us for any other characteristic data that may be required.
Photoelectric
V2T-7000/V2T-7000D
Sensors
Distance Y (m)
Distance Y (m)
Distance X (m)
Excess gain
Receiver Receiver
0.5 2.5
0 40 2.0
10
10 20 30 40 50 60
1.5
0.5
20 1.0
1.0 X
Emitting Receiving
Emitting X Interference
0.5
Photoelectric 1
1.5 Y Receiving area Y
Sensors Operation level
2.0
0 20 40 60 80 100 40 30 20 10 0 10 20 30 40 0 20 40 60 80 100
Sensing distance (m) Sensing distance X (m) Operating angle (°) Sensing distance X (m)
Specialized
Photoelectric V2R-1200/V2R-1200D
Sensors
Excess gain Sensing area Angular deviation Interference area (reflector V-61)
Laser 250 16
ーReceiver angle ‐
‐‐Emitter angle
800
Displacement 100 200
Sensors 150
12 θ 600
θ X
Distance Y (mm)
Distance Y (mm)
X
Distance X (m)
100 No interference area
Excess gain
50 V-61
Universal
0 8 400
Voltage 10 V-61 2 4 6 8 10 12 14
50
100 V-61
V2 4 200 X
Reflector
150 Sensor
Sensor Y Interference
200 X Y
V3, V4 1 Reflector
area
Operation level 250 0
0 2 4 6 8 10 12 14 16 40 30 20 10 0 10 20 30 40 0 2 4 6 8 10 12 14
V Sensing distance (m) Sensing distance X (m) Operating angle (°) Sensing distance X (m)
Photoelectric
Sensors
Sensor mounting Connector handling Other notes
Please mount the sensor using a The DC power connector can be Installing in the following locations
dedicated mounting bracket. changed between horizontal and vertical may result in malfunction:
2 types of mounting possible with 1 orientations. The connector will be fixed Dusty or steamy locations.
type of bracket depending on the in place when you push up the stopper. Locations where corrosive gas is generated.
installation location. Please note that since the connector can Locations with direct exposure to
only be moved in fixed directions, water or oil splashes.
turning it too forcefully in the wrong Locations where heavy vibrations
direction may damage it. or impacts may occur.
Photoelectric
When using a switching regulator for Sensors
the power supply, be sure to ground
the frame ground terminal. Specialized
Avoid wiring in parallel with or in the Photoelectric
Sensors
same piping as high-voltage wires or
power lines. Doing so may lead to Laser
Displacement
malfunctions caused by noise. Also, Sensors
Horizontal (H) Vertical (V) shorten the power supply and signal
Tighten the sensor mounting wires as much as possible.
screws with a tightening torque of Universal
Avoid using the transient state while Voltage
no more than 0.5 N·m. the power is on (approx. 150 ms).
Stopper
Please do not use for applications V2
that will affect the safety of the
V3, V4
worker’s hands or other body parts.
V
Reflector Receiver
For diffuse-reflective types (BGS types),
it is difficult for interference to arise
because of the narrow light axis, but
please mount with an awareness of the
characteristics of the interference area or
the characteristics of the sensing area.